Transcript
U – LED modules, converters and systems GENERAL ILLUMINATION
Umodule SPOT P350-2 umodule SPOT
Product description • Spotlights
OU T
• Downlights • High-flux LED module • Narrow colour temperature tolerance band • Compact design • Excellent thermal management1 • NTC for temperature control • High-power LED in chip-on-board technololgy • Beam characteristic: 140° • Uniform distribution of light
43
• Fixing holes for M3 screws • Connection: Cable 300 mm
SE D
Weight
48
• Cooling required
11 5.75
15 g
Typ. power at 1,400 mA2 6
53 W
Risk group (EN 62471:2008)
0
È Standards, page 2
Ø30 1 Ø38.5 2
42.25 37
• Built-in LED module
Technical data
Ø3.2
NTC tc
3.5 5.15 37.89 39.5
1.65
2.00 typ.
1 Minimal diameter reflector 2 Maximum diameter reflector
Ordering data
PH A
Colour temperatures and tolerances, page 5
Colour temperature
Type
3,000 K
LED P350-2 3000K 48x43
Article number 89601152
3,500 K
LED P350-2 3500K 48x43
89601154
4,000 K
LED P350-2 4000K 48x43
89601153
5,000 K
LED P350-2 5000K 48x43
89601160
Packaging: 20 pieces/carton
Specific technical data Type
Min. luminous flux at 1,400 mA2 3
Typ. luminous flux at 1,400 mA2 3
Typ. forward current4 5
Max. forward current4 5
Min. forward voltage2 6
Typ. forward voltage2 6
Max. forward Colour rendering index CRI voltage2 6
LED P350-2 3000K 48x43
3,250 lm
3,600 lm
1,400 mA
1,750 mA
33.3 V
38 V
44.8 V
> 80
LED P350-2 3500K 48x43
3,240 lm
3,610 lm
1,400 mA
1,750 mA
33.3 V
38 V
44.8 V
> 80
LED P350-2 4000K 48x43
3,700 lm
4,100 lm
1,400 mA
1,750 mA
33.3 V
38 V
44.8 V
> 80
LED P350-2 5000K 48x43
5,000 lm
5,300 lm
1,400 mA
1,750 mA
33.3 V
38 V
44.8 V
> 70
1 If
the max. temperature limits are exceeded, the life of the system will be greatly reduced or the system may be damaged. The temperature of the umodule SPOT at the tc-point is to be measured in the thermally stable state with a temperature sensor or or temperature-sensitive sticker as per EN 60598-1. For the precise position of the tc point see the drawing above.
2 At
tc = 65 °C.
3 Tolerance
range for optical data: ±15 %.
the max. operating current leads to an overload on the umodule SPOT. This may in turn result in a significant reduction in lifetime or even destruction of the umodule SPOT.
4 Exceeding 5 Max.
permissible surge current: 3 A, duration max. 10 µs.
6 Tolerance
range for electrical data: ±15 %.
All values for ta = 25 °C. For suitable converters please contact Tridonic Customer Service.
Data sheet 11/11-LED021-1 Subject to change without notice.
www.tridonic.com
1
U – LED modules, converters and systems GENERAL ILLUMINATION
Standards EN 62031 EN 62471
Typical heat sink surface
Thermal design and heat sink The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule SPOT will be greatly reduced or the umodule SPOT may be destroyed. Therefore the umodule SPOT P350-2 needs to be mounted onto a heat sink.
tc point, ambient temperature and lifetime The temperature at tc reference point is crucial for the light output and life time of a u product.
typical heat sink surface 693 cm² 813 cm² 1,241 cm² 2,620 cm²
Umodule SPOT P350-2, 1,750 mA ta tc Rth, hs-a 25 °C 65 °C 0.53 K/W 30 °C 65 °C 0.44 K/W 40 °C 65 °C 0.27 K/W 50 °C 65 °C 0.10 K/W
typical heat sink surface 1,260 cm² 1,501 cm² 2,429 cm² 6,371 cm²
OU T
Tridonic’s excellent thermal design for the umodule SPOT products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life time.
Umodule SPOT P350-2, 1,400 mA ta tc Rth, hs-a 25 °C 65 °C 0.70 K/W 30 °C 65 °C 0.59 K/W 40 °C 65 °C 0.38 K/W 50 °C 65 °C 0.17 K/W
For umodule SPOT P350-2 a tc temperature of 65 °C has to be complied in order to achieve an optimum between heat sink requirements, light output and life time. Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application.
Notes Values valid for: natural convection, heat sink material: aluminium ≥ 1 mm thick, Rth, hs-a = required thermal resistance of heat sink
The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. A thermal connection between umodule SPOT and heat sink with heat-conducting paste or heat conducting adhesive film is absolutely necessary. Additionally the umodule SPOT has to be fixed on the heat sink with M3 plastic screws to optimise the thermal connection.
Mounting instruction Thermal behaviour
SE D
umodule SPOT from Tridonic which have to be installed on a heat sink have to be connected with heat-conducting paste or heat conducting adhesive film and fixed with M3 plastic screws. The fixing/cooling surface must be cleaned before installing the u modules to remove all dirt, dust and grease.
storage temperature operating temperature tc max. (at typ. current)
2000
None of the components of the umodule SPOT (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. For further information please refer to to the brochure entitled “u installation instructions and guidelines”.
PH A
1800 1600 1400
If [mA]
1200
Temperature control An NTC resistor is on the board of the umodule SPOT P350-2 to control the tc temperature during the operation. Exact position see drawing on page 1. The details of the 220 kΩ NTC (order number B57431V2223J062) you can find in the data sheet of the manufacturer AVX (Nr. NB12QØØ224). T
-30 – 85 °C -30 – 50 °C 85 °C
1000
800 600 400 200
0
0
10
20
30
40
50 60 Tc [°C]
70
80
90
100
R25 = 220 kΩ, B25 / 100 = 4,500 K
Matrix temperature
RT / R25
α
25 °C
1.0000
4.8 % / K
30 °C
0.78759
4.7 % / K
35 °C
0.62406
4.6 % / K
Temperature
40 °C
0.49737
4.5 % / K
45 °C
0.39863
4.4 % / K
50 °C
0.32123
4.3 % / K
55 °C
0.26022
4.2 % / K
60 °C
0.21186
4.1 % / K
65 °C
0.17334
4.0 % / K
330 °C 340 °C 350 °C 360 °C 370 °C 380 °C 390 °C
70 °C
0.14249
3.9 % / K
75 °C
0.11767
3.8 % / K
80 °C
0.097598
3.7 % / K
85 °C
0.081300
3.6 % / K
f(soldering time) for the modules Max. time with optimized heat sink
15 s 12 s 10 s 5 s 3 s 2 s 1 s
– – – 15 s 12 s 10 s 5 s
The values apply for soldering without heat sink. To reduce the duration of soldering it is recommended to pre-heat the module at ta max., e.g. on a plate.
Data sheet 11/11-LED021-1 Subject to change without notice.
Max. time without heat sink
www.tridonic.com
2
U – LED modules, converters and systems GENERAL ILLUMINATION
tc temperature in °C
luminous flux in %
lifetime in h
80 70 50 80 70 50 80 70 50 80 70 50 80 70 50
29,000 47,000 91,000 28,000 45,000 87,000 26,000 42,000 81,000 23,000 35,000 75,000 15,000 22,000 49,000
25
45
65
75
85
Electrical supply/choice of converter umodule SPOT from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a converter which complies with the relevant standards. The use of u converters from Tridonic in combination with umodule SPOT guarantees the necessary protection for safe and reliable operation. If a converter other than Tridonic uconverter is used, it must provide the following protection: • Short-circuit protection • Overload protection • Overtemperature protection
OU T
Lifetime
umodule SPOT P350-2 must be supplied by a constant current converter. Operation with a constant voltage converter will lead to an irreversible damage of the module. Wrong polarity can damage the umodule SPOT P350-2.
EOS/ESD safety guidelines
SE D
The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp
Wiring Cable: AWG24; length 300 mm red +
black -
grey NTC
grey NTC
PH A
colour function
Data sheet 11/11-LED021-1 Subject to change without notice.
www.tridonic.com
3
U – LED modules, converters and systems GENERAL ILLUMINATION
Relative forward voltage and relative luminous flux 1,15
1,05
1,1
1,04 1,03 rel. voltage [a.u.]
rel. voltage [a. u.]
1,05 1 0,95 0,9
1,01 1
OU T
0,99
0,85
0,98
0,97 20
0,8 0
200
400
600
800 1000 1200 current [mA]
1400
1600
1800
Relative forward voltage at tc = 65 °C
30
40
30
40
50 Tc [°C]
60
70
80
85
60
70
80
85
1,14
1,4
1,12
1,2
1,1
rel. luminous flux [a.u.]
1
rel. luminous flux [a.u.]
1,02
0,6 0,4
1,06 1,04 1,02
SE D
0,8
1,08
1
0,98 0,96
0,2
0,94
0 0
200
400
600
800
1000
1200
1400
1600
0,92 20
1800
current [mA]
50 Tc [°C]
Relative luminous flux at tc = 65 °C
PH A
The diagrams based on statistic values. The real values can be different.
Optical characteristics Umodule SPOT P350-2
The optical design of the umodule SPOT product line ensures optimum homogenity for the light distribution. Umodule SPOT P350-2 140°: Light distribution
-30°
relative intensity Iv/Iv, max
100
80
-20°
-10°
0°
10°
20°
30°
-40°
-50°
60 -60°
40° 50° 60°
40
70° 80°
20
-90°
-100 -80 -60 -40 -20
0
20
40
60
80 100
90°
Data sheet 11/11-LED021-1 Subject to change without notice.
www.tridonic.com
4
U – LED modules, converters and systems GENERAL ILLUMINATION
Coordinates and tolerances according to CIE 1964 The specified colour coordinates are measured by a current impulse of 1,400 mA and a duration of 100 ms. The ambient temperature of the measurement is ta = 25 °C. The measurement tolerance of the colour coordinates are ± 0.01.
3,000 K y0 0,3990
OU T
x0 0,4460
Centre
100
0,4200 0,4150
80
norm. intensity [%]
0,4100 0,4050 0,4000 0,3950 0,3900
60
40
20
0,3850
0,4650
0,4600
0,4550
0,4500
0,4450
0,4400
0,4350
0,4300
0,4250
0,3800
0
380
420
460
500
660
700
740
780
540 580 620 660 wave length [nm]
700
740
780
540
580
620
wave length [nm]
SE D
MacAdam ellipse: 5SDCM
3,500 K
x0 0,4160
Centre
y0 0,3900
100
0,4100
PH A
0,4050
80
0,3950 0,3900 0,3850 0,3800
norm. intensity [%]
0,4000
60 40 20
0,3750
0,4350
0,4300
0,4250
0,4200
0,4150
0,4100
0,4050
0,4000
0,3950
0,3700
0 380
MacAdam ellipse: 5SDCM
Data sheet 11/11-LED021-1 Subject to change without notice.
www.tridonic.com
420
460
500
5
U – LED modules, converters and systems GENERAL ILLUMINATION
4,000 K x0 0,3860
Centre
y0 0,3780
100
0.4000 0.3950
80
0.3900
0.3800 0.3750 0.3700
60
40
OU T
norm. intensity [%]
0.3850
20
0.3650
0.4050
0.4000
0.3950
0.3900
0.3850
0.3800
0.3750
0.3700
0.3650
0.3600
0
380
420
460
500
660
700
740
780
540 580 620 660 wave length [nm]
700
740
780
540
580
620
wave length [nm]
MacAdam ellipse: 5SDCM
SE D
5,000 K x0 0,3530
Centre
y0 0,3590
100
0,3800 0,3750
80
norm. intensity [%]
0,3700 0,3650 0,3600 0,3550 0,3500
40 20
PH A
0,3450
0,3750
0,3700
0,3650
0,3600
0,3550
0,3500
0,3450
0,3400
0,3400
0,3350
60
0 380
420
460
500
MacAdam ellipse: 5SDCM
Data sheet 11/11-LED021-1 Subject to change without notice.
www.tridonic.com
6