Preview only show first 10 pages with watermark. For full document please download

Ds Talexxmodule Spot P350 2 En

   EMBED


Share

Transcript

U – LED modules, converters and systems GENERAL ILLUMINATION Umodule SPOT P350-2 umodule SPOT Product description • Spotlights OU T • Downlights • High-flux LED module • Narrow colour temperature tolerance band • Compact design • Excellent thermal management1 • NTC for temperature control • High-power LED in chip-on-board technololgy • Beam characteristic: 140° • Uniform distribution of light 43 • Fixing holes for M3 screws • Connection: Cable 300 mm SE D Weight 48 • Cooling required 11 5.75 15 g Typ. power at 1,400 mA2 6 53 W Risk group (EN 62471:2008) 0 È Standards, page 2 Ø30 1 Ø38.5 2 42.25 37 • Built-in LED module Technical data Ø3.2 NTC tc 3.5 5.15 37.89 39.5 1.65 2.00 typ. 1 Minimal diameter reflector 2 Maximum diameter reflector Ordering data PH A Colour temperatures and tolerances, page 5 Colour temperature Type 3,000 K LED P350-2 3000K 48x43 Article number 89601152 3,500 K LED P350-2 3500K 48x43 89601154 4,000 K LED P350-2 4000K 48x43 89601153 5,000 K LED P350-2 5000K 48x43 89601160 Packaging: 20 pieces/carton Specific technical data Type Min. luminous flux at 1,400 mA2 3 Typ. luminous flux at 1,400 mA2 3 Typ. forward current4 5 Max. forward current4 5 Min. forward voltage2 6 Typ. forward voltage2 6 Max. forward Colour rendering index CRI voltage2 6 LED P350-2 3000K 48x43 3,250 lm 3,600 lm 1,400 mA 1,750 mA 33.3 V 38 V 44.8 V > 80 LED P350-2 3500K 48x43 3,240 lm 3,610 lm 1,400 mA 1,750 mA 33.3 V 38 V 44.8 V > 80 LED P350-2 4000K 48x43 3,700 lm 4,100 lm 1,400 mA 1,750 mA 33.3 V 38 V 44.8 V > 80 LED P350-2 5000K 48x43 5,000 lm 5,300 lm 1,400 mA 1,750 mA 33.3 V 38 V 44.8 V > 70 1 If the max. temperature limits are exceeded, the life of the system will be greatly reduced or the system may be damaged. The temperature of the umodule SPOT at the tc-point is to be measured in the thermally stable state with a temperature sensor or or temperature-sensitive sticker as per EN 60598-1. For the precise position of the tc point see the drawing above. 2 At tc = 65 °C. 3 Tolerance range for optical data: ±15 %. the max. operating current leads to an overload on the umodule SPOT. This may in turn result in a significant reduction in lifetime or even destruction of the umodule SPOT. 4 Exceeding 5 Max. permissible surge current: 3 A, duration max. 10 µs. 6 Tolerance range for electrical data: ±15 %. All values for ta = 25 °C. For suitable converters please contact Tridonic Customer Service. Data sheet 11/11-LED021-1 Subject to change without notice. www.tridonic.com 1 U – LED modules, converters and systems GENERAL ILLUMINATION Standards EN 62031 EN 62471 Typical heat sink surface Thermal design and heat sink The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule SPOT will be greatly reduced or the umodule SPOT may be destroyed. Therefore the umodule SPOT P350-2 needs to be mounted onto a heat sink. tc point, ambient temperature and lifetime The temperature at tc reference point is crucial for the light output and life time of a u product. typical heat sink surface 693 cm² 813 cm² 1,241 cm² 2,620 cm² Umodule SPOT P350-2, 1,750 mA ta tc Rth, hs-a 25 °C 65 °C 0.53 K/W 30 °C 65 °C 0.44 K/W 40 °C 65 °C 0.27 K/W 50 °C 65 °C 0.10 K/W typical heat sink surface 1,260 cm² 1,501 cm² 2,429 cm² 6,371 cm² OU T Tridonic’s excellent thermal design for the umodule SPOT products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life time. Umodule SPOT P350-2, 1,400 mA ta tc Rth, hs-a 25 °C 65 °C 0.70 K/W 30 °C 65 °C 0.59 K/W 40 °C 65 °C 0.38 K/W 50 °C 65 °C 0.17 K/W For umodule SPOT P350-2 a tc temperature of 65 °C has to be complied in order to achieve an optimum between heat sink requirements, light output and life time. Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. Notes Values valid for: natural convection, heat sink material: aluminium ≥ 1 mm thick, Rth, hs-a = required thermal resistance of heat sink The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. A thermal connection between umodule SPOT and heat sink with heat-conducting paste or heat conducting adhesive film is absolutely necessary. Additionally the umodule SPOT has to be fixed on the heat sink with M3 plastic screws to optimise the thermal connection. Mounting instruction Thermal behaviour SE D umodule SPOT from Tridonic which have to be installed on a heat sink have to be connected with heat-conducting paste or heat conducting adhesive film and fixed with M3 plastic screws. The fixing/cooling surface must be cleaned before installing the u modules to remove all dirt, dust and grease. storage temperature operating temperature tc max. (at typ. current) 2000 None of the components of the umodule SPOT (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. For further information please refer to to the brochure entitled “u installation instructions and guidelines”. PH A 1800 1600 1400 If [mA] 1200 Temperature control An NTC resistor is on the board of the umodule SPOT P350-2 to control the tc temperature during the operation. Exact position see drawing on page 1. The details of the 220 kΩ NTC (order number B57431V2223J062) you can find in the data sheet of the manufacturer AVX (Nr. NB12QØØ224). T -30 – 85 °C -30 – 50 °C 85 °C 1000 800 600 400 200 0 0 10 20 30 40 50 60 Tc [°C] 70 80 90 100 R25 = 220 kΩ, B25 / 100 = 4,500 K Matrix temperature RT / R25 α 25 °C 1.0000 4.8 % / K 30 °C 0.78759 4.7 % / K 35 °C 0.62406 4.6 % / K Temperature 40 °C 0.49737 4.5 % / K 45 °C 0.39863 4.4 % / K 50 °C 0.32123 4.3 % / K 55 °C 0.26022 4.2 % / K 60 °C 0.21186 4.1 % / K 65 °C 0.17334 4.0 % / K 330 °C 340 °C 350 °C 360 °C 370 °C 380 °C 390 °C 70 °C 0.14249 3.9 % / K 75 °C 0.11767 3.8 % / K 80 °C 0.097598 3.7 % / K 85 °C 0.081300 3.6 % / K f(soldering time) for the modules Max. time with optimized heat sink 15 s 12 s 10 s 5 s 3 s 2 s 1 s – – – 15 s 12 s 10 s 5 s The values apply for soldering without heat sink. To reduce the duration of soldering it is recommended to pre-heat the module at ta max., e.g. on a plate. Data sheet 11/11-LED021-1 Subject to change without notice. Max. time without heat sink www.tridonic.com 2 U – LED modules, converters and systems GENERAL ILLUMINATION tc temperature in °C luminous flux in % lifetime in h 80 70 50 80 70 50 80 70 50 80 70 50 80 70 50 29,000 47,000 91,000 28,000 45,000 87,000 26,000 42,000 81,000 23,000 35,000 75,000 15,000 22,000 49,000 25 45 65 75 85 Electrical supply/choice of converter umodule SPOT from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a converter which complies with the relevant standards. The use of u converters from Tridonic in combination with umodule SPOT guarantees the necessary protection for safe and reliable operation. If a converter other than Tridonic uconverter is used, it must provide the following protection: • Short-circuit protection • Overload protection • Overtemperature protection OU T Lifetime umodule SPOT P350-2 must be supplied by a constant current converter. Operation with a constant voltage converter will lead to an irreversible damage of the module. Wrong polarity can damage the umodule SPOT P350-2. EOS/ESD safety guidelines SE D The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp Wiring Cable: AWG24; length 300 mm red + black - grey NTC grey NTC PH A colour function Data sheet 11/11-LED021-1 Subject to change without notice. www.tridonic.com 3 U – LED modules, converters and systems GENERAL ILLUMINATION Relative forward voltage and relative luminous flux 1,15 1,05 1,1 1,04 1,03 rel. voltage [a.u.] rel. voltage [a. u.] 1,05 1 0,95 0,9 1,01 1 OU T 0,99 0,85 0,98 0,97 20 0,8 0 200 400 600 800 1000 1200 current [mA] 1400 1600 1800 Relative forward voltage at tc = 65 °C 30 40 30 40 50 Tc [°C] 60 70 80 85 60 70 80 85 1,14 1,4 1,12 1,2 1,1 rel. luminous flux [a.u.] 1 rel. luminous flux [a.u.] 1,02 0,6 0,4 1,06 1,04 1,02 SE D 0,8 1,08 1 0,98 0,96 0,2 0,94 0 0 200 400 600 800 1000 1200 1400 1600 0,92 20 1800 current [mA] 50 Tc [°C] Relative luminous flux at tc = 65 °C PH A The diagrams based on statistic values. The real values can be different. Optical characteristics Umodule SPOT P350-2 The optical design of the umodule SPOT product line ensures optimum homogenity for the light distribution. Umodule SPOT P350-2 140°: Light distribution -30° relative intensity Iv/Iv, max 100 80 -20° -10° 0° 10° 20° 30° -40° -50° 60 -60° 40° 50° 60° 40 70° 80° 20 -90° -100 -80 -60 -40 -20 0 20 40 60 80 100 90° Data sheet 11/11-LED021-1 Subject to change without notice. www.tridonic.com 4 U – LED modules, converters and systems GENERAL ILLUMINATION Coordinates and tolerances according to CIE 1964 The specified colour coordinates are measured by a current impulse of 1,400 mA and a duration of 100 ms. The ambient temperature of the measurement is ta = 25 °C. The measurement tolerance of the colour coordinates are ± 0.01. 3,000 K y0 0,3990 OU T x0 0,4460 Centre 100 0,4200 0,4150 80 norm. intensity [%] 0,4100 0,4050 0,4000 0,3950 0,3900 60 40 20 0,3850 0,4650 0,4600 0,4550 0,4500 0,4450 0,4400 0,4350 0,4300 0,4250 0,3800 0 380 420 460 500 660 700 740 780 540 580 620 660 wave length [nm] 700 740 780 540 580 620 wave length [nm] SE D MacAdam ellipse: 5SDCM 3,500 K x0 0,4160 Centre y0 0,3900 100 0,4100 PH A 0,4050 80 0,3950 0,3900 0,3850 0,3800 norm. intensity [%] 0,4000 60 40 20 0,3750 0,4350 0,4300 0,4250 0,4200 0,4150 0,4100 0,4050 0,4000 0,3950 0,3700 0 380 MacAdam ellipse: 5SDCM Data sheet 11/11-LED021-1 Subject to change without notice. www.tridonic.com 420 460 500 5 U – LED modules, converters and systems GENERAL ILLUMINATION 4,000 K x0 0,3860 Centre y0 0,3780 100 0.4000 0.3950 80 0.3900 0.3800 0.3750 0.3700 60 40 OU T norm. intensity [%] 0.3850 20 0.3650 0.4050 0.4000 0.3950 0.3900 0.3850 0.3800 0.3750 0.3700 0.3650 0.3600 0 380 420 460 500 660 700 740 780 540 580 620 660 wave length [nm] 700 740 780 540 580 620 wave length [nm] MacAdam ellipse: 5SDCM SE D 5,000 K x0 0,3530 Centre y0 0,3590 100 0,3800 0,3750 80 norm. intensity [%] 0,3700 0,3650 0,3600 0,3550 0,3500 40 20 PH A 0,3450 0,3750 0,3700 0,3650 0,3600 0,3550 0,3500 0,3450 0,3400 0,3400 0,3350 60 0 380 420 460 500 MacAdam ellipse: 5SDCM Data sheet 11/11-LED021-1 Subject to change without notice. www.tridonic.com 6