Transcript
U – LED modules, converters and systems GENERAL ILLUMINATION
Umodule STARK SLE CLASSIC umodule STARK SLE
Product description • For spotlights and downlights
OU T
• High-flux LED module • High colour rendering index CRI > 90 • Low tolerances for colour temperatures (MacAdams 4) • Compact design • Diameter: 50 / 65 mm • Excellent thermal management1 • NTC for temperature control • High-power LED module in chip-on-board technololgy (COB) • Uniform distribution of light • Plug connection
35 19
• Red-white technology • Fixing holes for M3 screws
SE D
• Cooling required
30
Ø3,2
• Built-in LED module
42
35 23
• Constant colour over the dimming range from 5 to 100 % • Mixing Cap available accessory for 1,500 and 2,500 lm
Technical data Beam characteristic Ambient temperature ta Typ. tc point Weight
Risk group (EN 62471:2008)
-25 ... +55 °C
tc
2500 lm
tc
4000 lm
65 °C
Ordering data
15 g / 18 g
Colour temperature
Type
Article number
0
3.000 K
STARK SLE 1500 930 CLA
89601343
3.000 K
STARK SLE 2500 930 CLA
89601338
3.000 K
STARK SLE 4000 930 CLA
89601333
4.000 K
STARK SLE 1500 940 CLA
89601344
4.000 K
STARK SLE 2500 940 CLA
89601339
4.000 K
STARK SLE 4000 940 CLA
89601334
PH A
È
tc 1500 lm
140°
65
50
6,5
50
Accessories connection cable, page 2 Standards, page 3
Packaging: 10 pieces/carton
Colour temperatures and tolerances, page 6 Specific technical data Type
Photometric code
Typ, luminous flux2
Typ, forward current3 4 5
Efficacy Typ, forward voltage6 Power consumption Power consumption module system of the module
Efficacy Colour rendering of the system index CRI
STARK SLE 1500 930 CLA
930/4x9
1,500 lm
1,050 mA
17.4 V
18.3 W
20.7 W
82 lm/W
73 lm/W
90
STARK SLE 2500 930 CLA
930/4x9
2,500 lm
1,050 mA
29.4 V
30.9 W
34.9 W
81 lm/W
72 lm/W
90
STARK SLE 4000 930 CLA
930/4x9
4,000 lm
1,400 mA
34.8 V
48.7 W
55.1 W
82 lm/W
73 lm/W
90
STARK SLE 1500 940 CLA
940/4x9
1,500 lm
1,050 mA
17.4 V
18.3 W
20.7 W
82 lm/W
73 lm/W
90
STARK SLE 2500 940 CLA
940/4x9
2,500 lm
1,050 mA
29.4 V
30.9 W
34.9 W
81 lm/W
72 lm/W
90
STARK SLE 4000 940 CLA
940/4x9
4,000 lm
1,400 mA
34.8 V
48.7 W
55.1 W
82 lm/W
73 lm/W
90
All values at ta = 25 °C, tc = 65 °C. 1 If
the max, temperature limits are exceeded, the life of the system will be greatly reduced or the system may be damaged, The temperature of the umodule at the tc-point is to be measured in the thermally stable state with a temperature sensor or or temperature-sensitive sticker as per EN 60598-1, For the precise position of the tc point see the drawing above,
2 Tolerance
range for optical data: ±10 %,
the max, operating current leads to an overload on the umodule, This may in turn result in a significant reduction in lifetime or even destruction of the umodule,
3 Exceeding 4 Max,
permissible surge current: 3 A, duration max, 10 µs,
5 Tolerance
range current: ±5 %,
6 Tolerance
range voltage: ±10 %,
Data sheet 06/12-LED030-2 Subject to change without notice.
www.tridonic.com
1
ACCESSORIES
U – LED modules, converters and systems GENERAL ILLUMINATION
TALEXXaccessories CONNECT 10PIN PLUG / 4PIN CRIMP
Product description • Open wire ends for flexible use of the module Ordering data
• Halogen free
Length
Type
Article number
0.5 m
Connection cable 0.5m
24166485
OU T
• 10-pin plug to 4 open wires
1m
Connection cable 1.0m
24166483
2m
Connection cable 2.0m
24166484
ACCESSORIES
Packaging: 10 pieces/carton
Mixing cap
SE D
Product description
• Mixing chamber for homogenous light distribution • To push on the SLE housing
• Glow wire test acc. IEC 60695-2-11 at 700 °C passed
8,8
R12,9
PH A
8,8
R9,8
20 (d)
Ordering data Type
Article number
Diameter d
LED Mixing Cap STARK SLE
88167564
20 mm
LED Mixing Cap STARK SLE
88167565
24 mm
Data sheet 06/12-LED030-2 Subject to change without notice.
24 (d)
www.tridonic.com
2
U – LED modules, converters and systems GENERAL ILLUMINATION
Converter matrix – Umodule STARK SLE CLASSIC REMOTE LCI Type
LCI 050/1050 N020
LCI 050/1050 T020
LCI 055/1400 T020
LCAI 050/1050 N020
LCAI 050/1050 T020
LCAI 055/1400 T020
24166468
86459218
86459219
24166469
86459247
86459248
Art. no.
Assignable converter Type
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
STARK SLE 1500 930 CLA
89601343
1
1
1
1
–
–
1
1
1
1
–
–
STARK SLE 2500 930 CLA
89601338
1
1
1
1
–
–
1
1
1
1
–
–
STARK SLE 4000 930 CLA
89601333
–
–
–
–
STARK SLE 1500 940 CLA
89601344
1
1
1
1
89601339
1
1
1
1
89601334
–
–
–
–
1
–
–
–
–
1
1
–
1
1
1
1
–
–
–
–
1
1
1
1
–
–
1
1
–
–
–
–
1
1
OU T
STARK SLE 2500 940 CLA STARK SLE 4000 940 CLA
1
–
Converter matrix – Umodule STARK SLE CLASSIC
IN-BUILT LCI
Type
LCI 050/1050 R010
LCI 055/1400 O010
LCI 055/1400 R010
LCAI 050/1050 R010
LCAI 055/1400 O010
LCAI 055/1400 R010
86459216
24166470
86459217
86459245
24166471
86459246
Art. no.
Assignable converter
Type 89601343
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
1
1
–
–
–
–
1
1
–
–
–
–
SE D
STARK SLE 1500 930 CLA STARK SLE 2500 930 CLA
89601338
1
1
–
–
–
–
1
1
–
–
–
–
STARK SLE 4000 930 CLA
89601333
–
–
1
1
1
1
–
–
1
1
1
1
89601344
1
1
–
–
–
–
1
1
–
–
–
–
89601339
1
1
–
–
–
–
1
1
–
–
–
–
STARK SLE 4000 940 CLA
89601334
–
–
1
1
1
1
–
–
1
1
1
1
PH A
STARK SLE 1500 940 CLA STARK SLE 2500 940 CLA
Data sheet 06/12-LED030-2 Subject to change without notice.
www.tridonic.com
3
U – LED modules, converters and systems GENERAL ILLUMINATION
Standards EN 62031 EN 62471 EN 61347-1 EN 61547 EN 55015
EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp
Glow wire test according to IEC 60695-2-11 960 °C passed. Photometric code
OU T
Temperature control An NTC resistor is on the board of the umodule STARK SLE to control the tc temperature during the operation with a resistor value of 220 kΩ.
1st digit
2nd + 3rd digit
4th digit
5th digit
6th digit Lumen maintanance after 25% McAdams after of the lifetime (max.6000h) Code CRI Code Remaining lumen Colour temperature in McAdams 25% of the 7 67 – 76 7 ≥ 70 % lifetime Kelvin x 100 initial 8 77 – 86 8 ≥ 80 % (max.6000h) 9 87 – ≥90 9 ≥ 90 %
Thermal design and heat sink The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule STARK SLE will be greatly reduced or the umodule STARK SLE may be destroyed.
220
200
180
160 140 120 100 80 60 40 20
SE D
Therefore the umodule STARK SLE needs to be mounted onto a heat sink.
240
Resistance [kΩ]
Key for photometric code, e. g. 830 / 449
Tridonic’s excellent thermal design for the umodule STARK SLE products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life time. tc point, ambient temperature and lifetime The temperature at tc reference point is crucial for the light output and life time of a u product.
For umodule STARK SLE a tc temperature of 65 °C has to be complied in order to achieve an optimum between heat sink requirements, light output and life time.
PH A
Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. Mounting instruction
umodule STARK SLE from Tridonic which have to be installed on a heat sink have to be connected with heat-conducting paste or heat conducting adhesive film and fixed with M3 screws. The fixing/cooling surface must be cleaned before installing the u modules to remove all dirt, dust and grease. None of the components of the umodule STARK SLE (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. Max. torque for fixing: 0.5 Nm.
For further information please refer to to the brochure entitled “Technical Design-In-Guide SLE”.
0
25
35
40
45
60 55 50 Temperature [°C]
65
70
75
80
85
Heat sink values
Umodule STARK SLE CLASSIC 1.500 lm ta tc Rth, hs-a 25 °C 65 °C 1.7 K/W 35 °C 65 °C 1.1 K/W 65 °C 45 °C 0.6 K/W
Umodule STARK SLE CLASSIC 2,500 lm ta tc Rth, hs-a 25 °C 65 °C 0.8 K/W 35 °C 65 °C 0.5 K/W 45 °C 65 °C 0.1 K/W
Umodule STARK SLE CLASSIC 4,000 lm ta tc Rth, hs-a 25 °C 65 °C 0.3 K/W 35 °C 65 °C 0.1 K/W 45 °C 65 °C –
Notes The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. A thermal connection between umodule STARK SLE and heat sink with heat-conducting paste or heat conducting adhesive film is absolutely necessary. Additionally the umodule STARK SLE has to be fixed on the heat sink with M3 screws to optimise the thermal connection.
Data sheet 06/12-LED030-2 Subject to change without notice.
30
www.tridonic.com
4
U – LED modules, converters and systems GENERAL ILLUMINATION
Electrical supply/choice of converter umodule STARK SLE from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a converter which complies with the relevant standards. The use of u converters from Tridonic in combination with umodule STARK SLE guarantees the necessary protection for safe and reliable operation.
Thermal behaviour storage temperature operating temperature tc max. (at typ. current) max. humidity
-30 ... +80 °C +25 ... +55 °C 75 °C 0 ... 80 %
1400 If [mA]
1200 1000
umodule STARK SLE must be supplied by a constant current converter. Operation with a constant voltage converter will lead to an irreversible damage of the module.
800 600 400 200 0
OU T
If a converter other than Tridonic uconverter is used, it must provide the following protection: • Short-circuit protection • Overload protection • Overtemperature protection
1600
0
10
20
30
40
50 60 Tc [°C]
70
80
90
100
Wrong polarity can damage the umodule STARK SLE.
Wiring Cable: see page 2 (Accessories)
Lifetime tc temperature in °C
luminous flux in %
lifetime in h
80 70 50 80 70 50 80 70 50 80 70 50
60,000 81,000 132,000 44,000 64,000 110,000 32,000 50,000 91,000 25,000 41,000 81,000
red + LED
black - LED
grey NTC
grey NTC
50 Tc [°C]
60
SE D
25
colour function
45
65
75
PH A
Relative forward voltage and relative luminous flux 1,05
1,14 1,12 1,1
1,03
rel. luminous flux [a.u.]
relative voltage [a.u.]
1,04
1,02
1,01 1
0,99
30
40
50 Tc [°C]
60
70
1,06 1,04 1,02 1 0,98 0,96
0,98
0,97 20
1,08
0,94 75
0,92 20
30
40
70
75
The diagrams based on statistic values. The real values can be different.
Data sheet 06/12-LED030-2 Subject to change without notice.
www.tridonic.com
5
U – LED modules, converters and systems GENERAL ILLUMINATION
Optical characteristics Umodule STARK SLE The optical design of the umodule STARK SLE product line ensures optimum homogenity for the light distribution. Light distribution
-30°
80
-10°
0°
10°
20°
30° 40°
-40°
50°
-50°
60 -60°
60°
40
70°
80°
20 -100 -80 -60 -40 -20
0
20
40
60
80 100
90°
PH A
SE D
-90°
OU T
relative intensity Iv/Iv,max
100
-20°
Data sheet 06/12-LED030-2 Subject to change without notice.
www.tridonic.com
6
U – LED modules, converters and systems GENERAL ILLUMINATION
Coordinates and tolerances according to CIE 1964 The specified colour coordinates are measured by a current impulse with typical values of module and a duration of 100 ms. The ambient temperature of the measurement is ta = 25 °C. The measurement tolerance of the colour coordinates are ± 0.01.
3,000 K y0 0,3990
0,4200
100
0,4150
norm. intensity [%]
0,4100 0,4050 0,4000 0,3950 0,3900
80
60 40 20
0,3850
0,4650
0,4600
0,4550
0,4500
0,4450
0,4400
0,4350
0,4300
0,3800 0,4250
OU T
x0 0,4460
Centre
0 380
420
460
500
540 580 620 660 wave length [nm]
700
740
780
500
540 580 620 660 wave length [nm]
700
740
780
SE D
MacAdam ellipse: 4SDCM
4,000 K
x0 0,3860
Centre
y0 0,3780
100
0.4000 0.3950
PH A 0.3850 0.3800 0.3750 0.3700
norm. intensity [%]
80
0.3900
60 40 20
0.3650
0.4050
0.4000
0.3950
0.3900
0.3850
0.3800
0.3750
0.3700
0.3650
0.3600
0 380
MacAdam ellipse: 4SDCM
Data sheet 06/12-LED030-2 Subject to change without notice.
www.tridonic.com
420
460
7