Preview only show first 10 pages with watermark. For full document please download

Ds Talexxmodule Stark Sle Classic En

   EMBED


Share

Transcript

U – LED modules, converters and systems GENERAL ILLUMINATION Umodule STARK SLE CLASSIC umodule STARK SLE Product description • For spotlights and downlights OU T • High-flux LED module • High colour rendering index CRI > 90 • Low tolerances for colour temperatures (MacAdams 4) • Compact design • Diameter: 50 / 65 mm • Excellent thermal management1 • NTC for temperature control • High-power LED module in chip-on-board technololgy (COB) • Uniform distribution of light • Plug connection 35 19 • Red-white technology • Fixing holes for M3 screws SE D • Cooling required 30 Ø3,2 • Built-in LED module 42 35 23 • Constant colour over the dimming range from 5 to 100 % • Mixing Cap available accessory for 1,500 and 2,500 lm Technical data Beam characteristic Ambient temperature ta Typ. tc point Weight Risk group (EN 62471:2008) -25 ... +55 °C tc 2500 lm tc 4000 lm 65 °C Ordering data 15 g / 18 g Colour temperature Type Article number 0 3.000 K STARK SLE 1500 930 CLA 89601343 3.000 K STARK SLE 2500 930 CLA 89601338 3.000 K STARK SLE 4000 930 CLA 89601333 4.000 K STARK SLE 1500 940 CLA 89601344 4.000 K STARK SLE 2500 940 CLA 89601339 4.000 K STARK SLE 4000 940 CLA 89601334 PH A È tc 1500 lm 140° 65 50 6,5 50 Accessories connection cable, page 2 Standards, page 3 Packaging: 10 pieces/carton Colour temperatures and tolerances, page 6 Specific technical data Type Photometric code Typ, luminous flux2 Typ, forward current3 4 5 Efficacy Typ, forward voltage6 Power consumption Power consumption module system of the module Efficacy Colour rendering of the system index CRI STARK SLE 1500 930 CLA 930/4x9 1,500 lm 1,050 mA 17.4 V 18.3 W 20.7 W 82 lm/W 73 lm/W 90 STARK SLE 2500 930 CLA 930/4x9 2,500 lm 1,050 mA 29.4 V 30.9 W 34.9 W 81 lm/W 72 lm/W 90 STARK SLE 4000 930 CLA 930/4x9 4,000 lm 1,400 mA 34.8 V 48.7 W 55.1 W 82 lm/W 73 lm/W 90 STARK SLE 1500 940 CLA 940/4x9 1,500 lm 1,050 mA 17.4 V 18.3 W 20.7 W 82 lm/W 73 lm/W 90 STARK SLE 2500 940 CLA 940/4x9 2,500 lm 1,050 mA 29.4 V 30.9 W 34.9 W 81 lm/W 72 lm/W 90 STARK SLE 4000 940 CLA 940/4x9 4,000 lm 1,400 mA 34.8 V 48.7 W 55.1 W 82 lm/W 73 lm/W 90 All values at ta = 25 °C, tc = 65 °C. 1 If the max, temperature limits are exceeded, the life of the system will be greatly reduced or the system may be damaged, The temperature of the umodule at the tc-point is to be measured in the thermally stable state with a temperature sensor or or temperature-sensitive sticker as per EN 60598-1, For the precise position of the tc point see the drawing above, 2 Tolerance range for optical data: ±10 %, the max, operating current leads to an overload on the umodule, This may in turn result in a significant reduction in lifetime or even destruction of the umodule, 3 Exceeding 4 Max, permissible surge current: 3 A, duration max, 10 µs, 5 Tolerance range current: ±5 %, 6 Tolerance range voltage: ±10 %, Data sheet 06/12-LED030-2 Subject to change without notice. www.tridonic.com 1 ACCESSORIES U – LED modules, converters and systems GENERAL ILLUMINATION TALEXXaccessories CONNECT 10PIN PLUG / 4PIN CRIMP Product description • Open wire ends for flexible use of the module Ordering data • Halogen free Length Type Article number 0.5 m Connection cable 0.5m 24166485 OU T • 10-pin plug to 4 open wires 1m Connection cable 1.0m 24166483 2m Connection cable 2.0m 24166484 ACCESSORIES Packaging: 10 pieces/carton Mixing cap SE D Product description • Mixing chamber for homogenous light distribution • To push on the SLE housing • Glow wire test acc. IEC 60695-2-11 at 700 °C passed 8,8 R12,9 PH A 8,8 R9,8 20 (d) Ordering data Type Article number Diameter d LED Mixing Cap STARK SLE 88167564 20 mm LED Mixing Cap STARK SLE 88167565 24 mm Data sheet 06/12-LED030-2 Subject to change without notice. 24 (d) www.tridonic.com 2 U – LED modules, converters and systems GENERAL ILLUMINATION Converter matrix – Umodule STARK SLE CLASSIC REMOTE LCI Type LCI 050/1050 N020 LCI 050/1050 T020 LCI 055/1400 T020 LCAI 050/1050 N020 LCAI 050/1050 T020 LCAI 055/1400 T020 24166468 86459218 86459219 24166469 86459247 86459248 Art. no. Assignable converter Type Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. STARK SLE 1500 930 CLA 89601343 1 1 1 1 – – 1 1 1 1 – – STARK SLE 2500 930 CLA 89601338 1 1 1 1 – – 1 1 1 1 – – STARK SLE 4000 930 CLA 89601333 – – – – STARK SLE 1500 940 CLA 89601344 1 1 1 1 89601339 1 1 1 1 89601334 – – – – 1 – – – – 1 1 – 1 1 1 1 – – – – 1 1 1 1 – – 1 1 – – – – 1 1 OU T STARK SLE 2500 940 CLA STARK SLE 4000 940 CLA 1 – Converter matrix – Umodule STARK SLE CLASSIC IN-BUILT LCI Type LCI 050/1050 R010 LCI 055/1400 O010 LCI 055/1400 R010 LCAI 050/1050 R010 LCAI 055/1400 O010 LCAI 055/1400 R010 86459216 24166470 86459217 86459245 24166471 86459246 Art. no. Assignable converter Type 89601343 Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. 1 1 – – – – 1 1 – – – – SE D STARK SLE 1500 930 CLA STARK SLE 2500 930 CLA 89601338 1 1 – – – – 1 1 – – – – STARK SLE 4000 930 CLA 89601333 – – 1 1 1 1 – – 1 1 1 1 89601344 1 1 – – – – 1 1 – – – – 89601339 1 1 – – – – 1 1 – – – – STARK SLE 4000 940 CLA 89601334 – – 1 1 1 1 – – 1 1 1 1 PH A STARK SLE 1500 940 CLA STARK SLE 2500 940 CLA Data sheet 06/12-LED030-2 Subject to change without notice. www.tridonic.com 3 U – LED modules, converters and systems GENERAL ILLUMINATION Standards EN 62031 EN 62471 EN 61347-1 EN 61547 EN 55015 EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/com/en/technical-docs.asp Glow wire test according to IEC 60695-2-11 960 °C passed. Photometric code OU T Temperature control An NTC resistor is on the board of the umodule STARK SLE to control the tc temperature during the operation with a resistor value of 220 kΩ. 1st digit 2nd + 3rd digit 4th digit 5th digit 6th digit Lumen maintanance after 25% McAdams after of the lifetime (max.6000h) Code CRI Code Remaining lumen Colour temperature in McAdams 25% of the 7 67 – 76 7 ≥ 70 % lifetime Kelvin x 100 initial 8 77 – 86 8 ≥ 80 % (max.6000h) 9 87 – ≥90 9 ≥ 90 % Thermal design and heat sink The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule STARK SLE will be greatly reduced or the umodule STARK SLE may be destroyed. 220 200 180 160 140 120 100 80 60 40 20 SE D Therefore the umodule STARK SLE needs to be mounted onto a heat sink. 240 Resistance [kΩ] Key for photometric code, e. g. 830 / 449 Tridonic’s excellent thermal design for the umodule STARK SLE products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life time. tc point, ambient temperature and lifetime The temperature at tc reference point is crucial for the light output and life time of a u product. For umodule STARK SLE a tc temperature of 65 °C has to be complied in order to achieve an optimum between heat sink requirements, light output and life time. PH A Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. Mounting instruction umodule STARK SLE from Tridonic which have to be installed on a heat sink have to be connected with heat-conducting paste or heat conducting adhesive film and fixed with M3 screws. The fixing/cooling surface must be cleaned before installing the u modules to remove all dirt, dust and grease. None of the components of the umodule STARK SLE (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. Max. torque for fixing: 0.5 Nm. For further information please refer to to the brochure entitled “Technical Design-In-Guide SLE”. 0 25 35 40 45 60 55 50 Temperature [°C] 65 70 75 80 85 Heat sink values Umodule STARK SLE CLASSIC 1.500 lm ta tc Rth, hs-a 25 °C 65 °C 1.7 K/W 35 °C 65 °C 1.1 K/W 65 °C 45 °C 0.6 K/W Umodule STARK SLE CLASSIC 2,500 lm ta tc Rth, hs-a 25 °C 65 °C 0.8 K/W 35 °C 65 °C 0.5 K/W 45 °C 65 °C 0.1 K/W Umodule STARK SLE CLASSIC 4,000 lm ta tc Rth, hs-a 25 °C 65 °C 0.3 K/W 35 °C 65 °C 0.1 K/W 45 °C 65 °C – Notes The actual cooling surface can differ because of the material, the structural shape, outside influences and the installation situation. A thermal connection between umodule STARK SLE and heat sink with heat-conducting paste or heat conducting adhesive film is absolutely necessary. Additionally the umodule STARK SLE has to be fixed on the heat sink with M3 screws to optimise the thermal connection. Data sheet 06/12-LED030-2 Subject to change without notice. 30 www.tridonic.com 4 U – LED modules, converters and systems GENERAL ILLUMINATION Electrical supply/choice of converter umodule STARK SLE from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a converter which complies with the relevant standards. The use of u converters from Tridonic in combination with umodule STARK SLE guarantees the necessary protection for safe and reliable operation. Thermal behaviour storage temperature operating temperature tc max. (at typ. current) max. humidity -30 ... +80 °C +25 ... +55 °C 75 °C 0 ... 80 % 1400 If [mA] 1200 1000 umodule STARK SLE must be supplied by a constant current converter. Operation with a constant voltage converter will lead to an irreversible damage of the module. 800 600 400 200 0 OU T If a converter other than Tridonic uconverter is used, it must provide the following protection: • Short-circuit protection • Overload protection • Overtemperature protection 1600 0 10 20 30 40 50 60 Tc [°C] 70 80 90 100 Wrong polarity can damage the umodule STARK SLE. Wiring Cable: see page 2 (Accessories) Lifetime tc temperature in °C luminous flux in % lifetime in h 80 70 50 80 70 50 80 70 50 80 70 50 60,000 81,000 132,000 44,000 64,000 110,000 32,000 50,000 91,000 25,000 41,000 81,000 red + LED black - LED grey NTC grey NTC 50 Tc [°C] 60 SE D 25 colour function 45 65 75 PH A Relative forward voltage and relative luminous flux 1,05 1,14 1,12 1,1 1,03 rel. luminous flux [a.u.] relative voltage [a.u.] 1,04 1,02 1,01 1 0,99 30 40 50 Tc [°C] 60 70 1,06 1,04 1,02 1 0,98 0,96 0,98 0,97 20 1,08 0,94 75 0,92 20 30 40 70 75 The diagrams based on statistic values. The real values can be different. Data sheet 06/12-LED030-2 Subject to change without notice. www.tridonic.com 5 U – LED modules, converters and systems GENERAL ILLUMINATION Optical characteristics Umodule STARK SLE The optical design of the umodule STARK SLE product line ensures optimum homogenity for the light distribution. Light distribution -30° 80 -10° 0° 10° 20° 30° 40° -40° 50° -50° 60 -60° 60° 40 70° 80° 20 -100 -80 -60 -40 -20 0 20 40 60 80 100 90° PH A SE D -90° OU T relative intensity Iv/Iv,max 100 -20° Data sheet 06/12-LED030-2 Subject to change without notice. www.tridonic.com 6 U – LED modules, converters and systems GENERAL ILLUMINATION Coordinates and tolerances according to CIE 1964 The specified colour coordinates are measured by a current impulse with typical values of module and a duration of 100 ms. The ambient temperature of the measurement is ta = 25 °C. The measurement tolerance of the colour coordinates are ± 0.01. 3,000 K y0 0,3990 0,4200 100 0,4150 norm. intensity [%] 0,4100 0,4050 0,4000 0,3950 0,3900 80 60 40 20 0,3850 0,4650 0,4600 0,4550 0,4500 0,4450 0,4400 0,4350 0,4300 0,3800 0,4250 OU T x0 0,4460 Centre 0 380 420 460 500 540 580 620 660 wave length [nm] 700 740 780 500 540 580 620 660 wave length [nm] 700 740 780 SE D MacAdam ellipse: 4SDCM 4,000 K x0 0,3860 Centre y0 0,3780 100 0.4000 0.3950 PH A 0.3850 0.3800 0.3750 0.3700 norm. intensity [%] 80 0.3900 60 40 20 0.3650 0.4050 0.4000 0.3950 0.3900 0.3850 0.3800 0.3750 0.3700 0.3650 0.3600 0 380 MacAdam ellipse: 4SDCM Data sheet 06/12-LED030-2 Subject to change without notice. www.tridonic.com 420 460 7