Preview only show first 10 pages with watermark. For full document please download

Ds835i/ds835it - Bosch Security Systems

   EMBED


Share

Transcript

Installation Instructions for the DS835i/DS835iT Series TriTech Microwave/PIR Intrusion Detectors with Pet Immunity 1.0 Description The DS835i and DS835iT Series are high performance TriTech passive infrared (PIR)/microwave (MW) motion detectors that use advanced signal processing to provide outstanding catch performance and unsurpassed false alarm immunity. They are designed to detect movement of a human body in the interior of a structure as it moves across the detector's field of view. When motion is detected, the DS835i and DS835iT send an alarm signal to the control panel. With the Pet Friendly pet immunity, these detectors will not detect a dog up to 100 lbs (45 k) or two 60-lb (26 k) dogs, up to 10 cats, numerous rodents, or flying birds. This pet immunity feature has not been tested by Underwriters Laboratories, Inc. (UL). 2.0 Specifications • Input Power: 6 VDC to 15 VDC, 16 mA standby (up to 35 mA during walk testing and alarm). Only use a limited power source up to 5 A maximum. • Standby Power: • Alarm Relay: No internal standby battery. For UL Certificated installations, the control unit or a Listed burglary power supply must provide 4 hrs (64 mAh) standby power. Silent operating Normally Closed reed relay. Contacts rated 3 W, 125 mA, 28 VDC maximum for DC resistive loads; protected by a 4.7 Ω, 1/2 W resistor in the common “C” leg of the relay. Do not use with capacitive or inductive loads. • Temperature: Storage and operating temperature range is -40°F to +120°F (-40°C to +49°C). For UL Certificated installations, the temperature range is +32°F to +120°F (0°C to +49°C). 3.2 3.0 Installation 3.1 Remove the cover using a small flat-blade screwdriver. • Microwave Frequency: DS835i/835iT: 10.525 GHz (UL Listed) DS835iTA: 10.687 GHz (Export only, not UL Listed) DS835iTB: 9.9 GHz (Export only, not UL Listed) • Coverage: 35 ft by 35 f. (10.7 m by 10.7 m) • Tamper: ("T" models only) Normally Closed (with cover on). Contacts rated at 28 VDC, 125 mA max. Connect tamper circuit to a 24-hour protection circuit. • Options: B335 Low Profile Swivel Mount Bracket, B338 Ceiling Mount Bracket. (Using brackets is not recommended for pet applications and might reduce range and increase dead zone areas). • Reading Bosch Security Systems, Inc. Product Date Codes For Product Date Code information, refer to the Bosch Security Systems, Inc. Web site at: http://www.boschsecurity.com/datecodes/ Press the vertical adjust tab toward the side of the base and lift out the board. 3.3 Select a mounting location. Mount the sensor where an intruder will most likely cross through the coverage pattern. LED ON Bottom of Detector 7.5-9ft Optional anti-tamper screws at each end Insert screwdriver here or here 3.4 7.5-9ft 3.5 Avoid: Observe the Pet Immunity mounting restrictions. Note: The upper areas are not pet immune. Mounting Outdoors Direct Sunlight Direct Hot or Cold Drafts NO OK Pet Immune Area Moving Objects Windows and Uninsulated Walls Heat Sources 7.5 - 9 ft. (2.3 - 2.7 m) Air Conditioning Outlets Mount the detector 7.5 - 9 feet (2.3 - 2.7 meters) above the floor Don't point where pets can climb. 3.6 Mount the detector. 3.7 Note: Avoid possible circuit board damage by only using the mounting hardware that is provided in the appropriate punch-out mounting holes. Thinwall knockouts for wiring Corner Mount Wire the detector. 6-15 VDC - 9 ft. = 7.5 (2.3 - 2.7 m) Alarm Contacts 3.8 Snap the board into the base so the notch aligns with the tab. (DS835iT only) Tamper Contacts - + Remove LED ON LED Areas if using the B335 Bracket Surface Mount 7.5-9ft Note: Only use Limited Power Source up to 5 A maximum. 3.10 Select LED operation. 7.5-9ft Normally Closed contacts Do not use the B335 Bracket in pet applications Don't overtighten the mounting screws Cover may not attach correctly 3.9 7.5-9ft In non-pet applications only, if look-down is desired, peel away the look-down mask. Do not remove the clear plastic lens. 3.11 Microwave range is pre-set. Field adjustment is not required. Note: If you choose to adjust the range, set the adjustment as low as possible for proper catch performance. Be sure to walk test throughout the coverage pattern after any adjustment. LED ON LED ON INCREASE 7.5-9ft 7.5-9ft 7.5-9ft ON OFF 7.5-9ft 7.5-9ft Peel away the mask 3.12 Walk test the detector at the time of installation and annually thereafter. 4.0 Coverage Patterns 0 Green = PIR detect Yellow = MW detect 10.7 5.35 Meters 17.5 1 Red = Alarm 10 7.5 0 10.7 3 10 35 0 Feet Look Down 5 6777 56- 4566 55 3444 Microwave Coverage PIR Coverage 0 6 7 1 2 3 4 5 6 7 8 91011 8 9 11 10 17.5 5.35 0 Feet Note: Wait 2 minutes after the initial power-up to perform Walk Tests. 5.0 Meters 0 4 This detector contains an environmental stabilization circuit. After the initial powerup, the detector needs approximately 2 min. to warm up. During this time, the detector does not respond to any movement. 0 2 3 Microwave Coverage PIR Coverage 7.5-9ft Do not use excessive force when adjusting the microwave pot. 10 20 30 35 12 23 34 45 56 67 22 33 44 55 66 77 DS835i Lens (inside view) 2333 0 12- 122 11 Although generally not required, if masking is desired, the lens diagram shows the appropriate areas to be masked. Use an opaque material (such as, electrical tape) to mask the desired areas. FCC Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference, including interference that may cause undesired operation. Changes or modifications not expressly approved by Bosch Security Systems. Inc. can void the user’s authority to operate the equipment. © 2011 Bosch Security Systems, Inc. 130 Perinton Parkway, Fairport, New York 14450 www.boschsecurity.com 1/11 DS835i/835iT Installation Instructions P/N: F01U035203-02 Page 2