Transcript
DSH Commercial 3 - 5 Tons Packaged Heat Pumps 14 SEER / Up to 12 EER 8.0 HSPF Cooling Capacity: 36,000 — 60,000 BTU/h Heating Capacity: 36,000 — 57,000 BTU/h
■ Contents
Nomenclature......................................... 2 Product Specifications............................ 4 Expanded Cooling Data.......................... 7 Airflow Data.......................................... 13 Crankercase Heater ............................. 21 Expanded Heating Data ....................... 22 Heat Kit Electrical Data ........................ 23 Dimensions........................................... 26 Wiring Diagrams .................................. 30 – for Models with DDC Controls............... 36 Accessories .......................................... 46
■ Standard Features • • • • • • • • • • • • • •
High-efficiency scroll compressor Copper tube / aluminum fin coils High- and low-pressure switches Refrigerant accumulator Contactor with lugs High-capacity, steel-cased filter drier Heater kits with single-point entry 24-volt terminal strip Convertible airflow orientation Easy to service Built-in filter rack with standard 2" filters Bottom utility entry AHRI Certified; ETL Listed 3-5 Tons with single speed blower motor units meet the performance specified in Table 6.8.1-2 of ASHRAE Standard 90.1-2013
■ Cabinet Features
• Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish • Full Perimeter Rail • Sloped drain pan
* Complete warranty details available from your local distributor or manufacturer’s representative or at www.daikincomfort.com.
SS-DSH3
www.daikinac.com
4/17 Supersedes 2/17
Nomenclature
D 1
S 2
H 3
060 4,5,6
020 7,8,9
3 10
B 11
* 12
* 13
* 14
A * 15 16 Revision Levels Major & Minor
Brand D Daikin
X A B C D E F
Configuration C Standard Efficiency (6 - 25 Tons) S Standard Efficiency (3 - 5 Tons) T High Efficiency (3 - 5 Tons) Application C Cooling1 G Gas Heat H Heat Pump1 Nominal Cooling Capacity 036 3 Tons 102 048 4 Tons 120 060 5 Tons 150 072 6 Tons 180 090 7½ Tons 240
G H J 8½ Tons 10 Tons 12½ tons 15 Tons 20 Tons
300 25 Tons K L
Nominal Heating Capacity Gas/Electric A/C H/P Factory-Installed Electric Heat 045 45,000 BTU/h XXX No Heat 090 90,000 BTU/h 010 10 kW 030 30 kW 115 115,000 BTU/h 015 15 kW 031 30 kW 140 140,000 BTU/h 016 15 kW 045 45 kW 210 210,000 BTU/h 018 18 kW 046 45 kW 350 350,000 BTU/h 020 20 kW 060 60 kW 400 400,000 BTU/h 025 25 kW See product specifications for heat size(s) available for each capacity.
M N O P Q R
Voltage 1 208-230/1/60 3 208-230/3/60
4 7
460/3/60 575/3/60
T U
Supply Fan/Drive Type/Motor B Belt Drive (single speed) V Two-Speed Belt Drive (also designates 6-Ton D Direct Drive (3-5 Tons) with two-stage compressor) H High Static (single-speed Belt Drive models only) Factory-Installed Options A Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer; B DDC-BACnet protocol DDC-BACnet protocol; F Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) DDC-BACnet protocol V Low-Leak Downflow Economizer H Disconnect Switch (non-fused) W Low-Leak Downflow Economizer J Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) Disconnect Switch (non-fused) X No Options M Disconnect Switch (non-fused); DDC-BACnet protocol Note: Not all options available for all products. X= No Options in character 13th
1
2
www.daikinac.com
V W Y Z
Factory-Installed Options No Options Non-powered convenience outlet Powered convenience outlet Low-ambient kit Return air smoke detector Supply air smoke detector Non-powered convenience outlet; Low-ambient kit Non-powered convenience outlet; Return air smoke detector Non-powered convenience outlet; Supply air smoke detector Non-powered convenience outlet; Return & Supply air smoke detectors Non-powered convenience outlet; Low-ambient kit; Supply air smoke detector Non-powered convenience outlet; Low-ambient kit Return & Supply air smoke detectors Powered convenience outlet; Low-ambient kit Powered convenience outlet; Return air smoke detector Powered convenience outlet; Return & Supply air smoke detectors Powered convenience outlet; Supply air smoke detector Powered convenience outlet; Low-ambient kit; Return air smoke detector Powered convenience outlet; Low-ambient kit; Supply air smoke detector Powered convenience outlet; Low-ambient kit; Return & Supply air smoke detectors Non-powered convenience outlet; Low-ambient kit; Return air smoke detector Low-ambient kit; Return air smoke detector Low-ambient kit; Supply air smoke detector Low-ambient kit; Return & Supply air smoke detectors Return & Supply air smoke detectors
Factory-Installed Options Standard Aluminized Heat Exchanger Stainless-Steel Heat Exchanger Hinged Panels Stainless-Steel Heat Exchanger; Hinged Panels B Phase Monitor J Stainless Steel Heat Exchanger; Phase Monitor M Hinged Panel; Phase Monitor L Stainless-Steel Heat Exchanger; Hinged Panels; Phase Monitor X S D K
SS-DSH3
Nomenclature
Factory-Installed Options • Stainless-Steel Heat Exchanger (Gas only units): A tubular heat exchanger made of 409-type stainless steel is installed in the unit. • Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3- to 6-ton units, cooling operation is extended from 60°F ambient temperature to 35°F outside air temperature. On 7½ -20 ton units, cooling operation is extended from 35°F ambient temperature to 0°F outside air temperature. For 25 ton units, cooling operation is extended from 24°F ambient temperature to 0°F outside air temperature. • Economizers (Downflow): Based on air conditions, can provide outside air to cool the space. • Electric Heat Kits (A/C and Heat Pump units only): Available in all voltage options. • Non-powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. • Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit. When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.5A for 208/230V units, increase by 3.75A for 460V units, and by 3A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. • Disconnect Switch (non-fused; 3-phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning and heat pump models, the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. • Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit. • Hinged Access Panels: Allows access to unit’s major components. Combined with latches for easy access to control box, compressor, filters and blower motor. Available on all units. • Two-speed indoor fan blower models are available on 6, 7½, 8½, 10, 12½, 15, 20 & 25 ton units. Section 6.4.3.10.b of ASHRAE Standard 90.1-2010 and Section 6.5.3.2.1.a of ASHRAE Standard 90.1-2013 require a minimum of two fan speeds. Section 140.4(m)1 of California Energy Commission Title 24 2013 contains a similar provision. When the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling, the fan operates at low speed, which is 66% of full speed. When the units operate on a call for the second stage of cooling, the fan operates at full speed. In heating operation, the fan operates at full speed. During ventilation operation, the fan operates at low speed. • Phase Monitor: Phase monitor (3 phase only), available for 3 - 25 ton DS, DC and DT series models. Phase monitor shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. • DDC Controller: DDC communicating controller, available for 3 - 25 ton DS, DC and DT series models with on-board BACnet® communication interface.
SS-DSH3
www.daikinac.com
3
Product Specifications — 3 Tons
Cooling Capacity Total BTU/h Sensible BTU/h SEER / EER Decibels AHRI Reference #s Heating Capacity BTU/h / COP (47° F) BTU/h / COP (17° F) HSPF Evaporator Motor / Coil Motor Type Indoor Nominal CFM Motor Speed Tap (Cooling) Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Filter Size (") Drain Size (NPT) R-410A Refrigerant Charge Cir #1 (oz.) Evaporator Coil Face Area (ft²) Rows Deep / Fins per Inch Belt Drive Evap Fan Data # of Wheels (D x W) Motor Sheave Blower Sheave / Belt Condenser Fan / Coil Quantity of Condenser Fan Motors Horsepower - RPM Fan Diameter/ # Fan Blades Outdoor Nominal CFM Face Area (ft²) Rows Deep/ Fins per Inch
Piston Size (Heating) Compressor Quantity / Type/ Stage Compressor RLA / LRA Electrical Data Voltage-Phase-Frequency Indoor Blower HP / FLA Max External Static Outdoor Fan HP / FLA Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² Power Supply Conduit Hole Low-Voltage Conduit Hole Operating Weight (lbs) Ship Weight (lbs)
DSH036 ***1D***A*
DSH036 ***3D***A*
DSH036 ***3B***A*
DSH036 ***4B***A*
DSH036 ***7B***A*
36,000 26,600 14 / 12 78 9967138
36,000 26,600 14 / 12 78 9967141
36,000 26,600 14 / 12 78 9952135
36,000 26,600 14 / 12 78 9952137
36,000 26,600 14 / 12 78 9952139
36,000 / 3.6 19,000 / 2.3 8.0
36,000 / 3.6 19,000 / 2.3 8.0
36,000 / 3.6 19,000 / 2.3 8.0
36,000 / 3.6 19,000 / 2.3 8.0
36,000 / 3.6 19,000 / 2.3 8.0
Direct Drive 1,250 LOW 2.46 ⅓ - 910 0.068 (4) 14" x 20" x 2" ¾" 158 7.0 4 / 16
Direct Drive 1,250 LOW 2.46 ⅓ - 910 0.068 (4) 14" x 20" x 2" ¾" 158 7.0 4 / 16
Belt Drive 1,200 --3.4 1.0 - 1725 0.068 (4) 14" x 20" x 2" ¾" 170 7.0 4 / 16
Belt Drive 1,200 --1.7 1.0 - 1725 0.068 (4) 14" x 20" x 2" ¾" 170 7.0 4 / 16
Belt Drive 1,200 --2.3 1.5 - 1725 0.068 (4) 14" x 20" x 2" ¾" 170 7.0 4 / 16
-------------
-------------
1 (11" x 10") 1VL34 x ⅝ AK61 x 1 / AX51
1 (11" x 10") 1VL34 x ⅝ AK61 x 1 / AX51
1 (11" x 10") 1VL34 x ⅝ AK61 x 1 / AX51
1 ¼ - 1,075 22 / 4 3,800 17.0 2 / 18 0.053
1 ¼ - 1,075 22 / 4 3,800 17.0 2 / 18 0.053
1 ¼ - 1,075 22 / 4 3,800 17.0 2 / 18 0.053
1 ¼ - 1075 22 / 4 3,800 17.0 2 / 18 0.053
1 ¼ - 1,075 22 / 4 3,800 17.0 2 / 18 0.053
1 / Scroll / Single 16.7 / 79.0
1 / Scroll / Single 10.4 / 73.0
1 / Scroll / Single 10.5 / 73.0
1 / Scroll / Single 5.8 / 38.0
1 / Scroll / Single 3.8 / 36.5
208/230-1-60 ⅓ / 2.46 0.5" ¼ / 1.4 25 40 1.125" ½" 580 605
208/230-3-60 ⅓ / 2.46 0.5" ¼ / 1.4 17 25 1.125" ½" 580 605
208/230-3-60 1.0 / 3.4 1.0" ¼ / 1.4 18 25 1.125 ½" 580 605
460-3-60 1.0 / 1.7 1.0" ¼ / 0.7 10 15 1.125 ½" 580 605
575-3-60 1.5 / 2.3 1.0" ¼ / 0.55 8 15 1.125 ½" 580 605
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed.
4
www.daikinac.com
SS-DSH3
Product Specifications — 4 Tons
Cooling Capacity Total BTU/h Sensible BTU/h SEER / EER Decibels AHRI Reference #s Heating Capacity BTU/h / COP (47° F) BTU/h / COP (17° F) HSPF Evaporator Motor / Coil Motor Type Indoor Nominal CFM Motor Speed Tap (Cooling) Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Filter Size (") Drain Size (NPT) R-410A Refrigerant Charge Cir #1 (oz.) Evaporator Coil Face Area (ft²) Rows Deep / Fins per Inch Belt Drive Evap Fan Data # of Wheels (D x W) Motor Sheave Blower Sheave / Belt Condenser Fan / Coil Quantity of Condenser Fan Motors Horsepower - RPM Fan Diameter/ # Fan Blades Outdoor Nominal CFM Face Area (ft²) Rows Deep/ Fins per Inch
Piston Size (Heating) Compressor Quantity / Type/ Stage Compressor RLA / LRA Electrical Data Voltage-Phase-Frequency Indoor Blower HP / FLA Max External Static Outdoor Fan HP / FLA Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² Power Supply Conduit Hole Low-Voltage Conduit Hole Operating Weight (lbs) Ship Weight (lbs)
DSH048 ***1D***A*
DSH048 ***3D***A*
DSH048 ***3B***A*
DSH048 ***4B***A*
DSH048 ***7B***A*
48,000 35,520 14 / 12 78 9967139
48,000 35,520 14 / 12 78 9967142
46,500 34,875 14 / 12 78 9956243
46,500 34,875 14 / 12 78 9956244
46,500 34,875 14 / 12 78 9956245
45,000 / 3.6 25,000 / 2.3 8.0
45,000 / 3.6 25,000 / 2.3 8.0
45,500 / 3.6 25,000 / 2.3 8.0
45,500 / 3.6 25,000 / 2.3 8.0
45,500 / 3.6 25,000 / 2.3 8.0
Direct Drive 1,650 MED 2.8 ¾ -1,025 0.076 (4) 14" x 20" x 2" ¾" 178 7.8 4 / 16
Direct Drive 1,650 MED 2.8 ¾ -1,025 0.076 (4) 14" x 20" x 2" ¾" 178 7.8 4 / 16
Belt Drive 1,600 --3.4 1.0 - 1,725 0.076 (4) 14" x 20" x 2" ¾" 173 7.8 4 / 16
Belt Drive 1,600 --1.7 1.0 - 1,725 0.076 (4) 14" x 20" x 2" ¾" 173 7.8 4 / 16
Belt Drive 1,600 --2.3 1.5 - 1,725 0.076 (4) 14" x 20" x 2" ¾" 173 7.8 4 / 16
-------------
-------------
1 (11" x 10") VL40 x ⅝ AK66 x 1 / AX52
1 (11" x 10") VL40 x ⅝ AK66 x 1 / AX52
1 (11" x 10") VL40 x ⅝ AK66 x 1 / AX52
1 ¼ / 1,075 22 / 4 3,800 17 2 / 18 0.057
1 ¼ / 1,075 22 / 4 3,800 17 2 / 18 0.057
1 ¼ / 1,075 22 / 4 3,800 17 2 / 18 0.057
1 ¼ / 1,050 22 / 4 3,800 17 2 / 18 0.057
1 ¼ / 1,050 22 / 4 3,800 17 2 / 18 0.057
1 / Scroll / Single 19.9 / 109
1 / Scroll / Single 13.1/ 83.1
1 / Scroll / Single 13.1 / 83.1
1 / Scroll / Single 6.1 / 41
1 / Scroll / Single 4.4 / 33
208/230-1-60 ¾ / 2.8 0.5" ¼ / 1.4 29 45 1.125" ½" 585 610
208/230-3-60 ¾ / 2.8 0.5" ¼ / 1.4 21 30 1.125" ½" 585 610
208/230-3-60 1.0 / 3.4 1.0" ¼ / 1.4 21 30 1.125 ½" 585 610
460-3-60 1.0 / 1.7 1.0" ¼ / 0.7 10 15 1.125 ½" 585 610
575-3-60 1.5 / 2.3 1.0" ¼ / 0.55 8 15 1.125 ½" 585 610
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed.
SS-DSH3
www.daikinac.com
5
Product Specifications — 5 Tons
Cooling Capacity Total BTU/h Sensible BTU/h SEER / EER Decibels AHRI Reference #s Heating Capacity BTU/h / COP (47° F) BTU/h / COP (17° F) HSPF Evaporator Motor / Coil Motor Type Indoor Nominal CFM Motor Speed Tap (Cooling) Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Filter Size (") Drain Size (NPT) R-410A Refrigerant Charge Cir #1 (oz.) Evaporator Coil Face Area (ft²) Rows Deep / Fins per Inch Belt Drive Evap Fan Data # of Wheels (D x W) Motor Sheave Blower Sheave / Belt Condenser Fan / Coil Quantity of Condenser Fan Motors Horsepower - RPM Fan Diameter/ # Fan Blades Outdoor Nominal CFM Face Area (ft²) Rows Deep/ Fins per Inch
Piston Size (Heating) Compressor Quantity / Type/ Stage Compressor RLA / LRA Electrical Data Voltage-Phase-Frequency Indoor Blower HP / FLA Max External Static Outdoor Fan HP / FLA Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² Power Supply Conduit Hole Low-Voltage Conduit Hole Operating Weight (lbs) Ship Weight (lbs)
DSH060 ***1D***A*
DSH060 ***3D***A*
DSH060 ***3B***A*
DSH060 ***4B***A*
DSH060 ***7B***A*
60,000 44,000 14 / 12 78 9967140
60,000 44,000 14 / 12 78 9967143
60,000 44,000 14 / 12 78 9952136
60,000 44,000 14 / 12 78 9952138
60,000 44,000 14 / 12 78 9952140
57,000 / 3.6 32,000 / 2.4 8.0
57,000 / 3.6 32,000 / 2.4 8.0
57,000 / 3.6 32,000 / 2.3 8.0
57,000 / 3.6 32,000 / 2.3 8.0
57,000 / 3.6 32,000 / 2.3 8.0
Direct Drive 2,000 T3 6.90 1.0 - 1050 0.086 (4) 16" x 20" x 2" ¾" 254 8.9 4 / 16
Direct Drive 2,000 T3 6.90 1.0 - 1050 0.086 (4) 16" x 20" x 2" ¾" 254 8.9 4 / 16
Belt 1,800 --3.0 1.0 - 1,760 0.089 (4) 16" x 20" x 2" ¾" 230 8.9 4 / 16
Belt 1,800 --1.5 1.0 - 1,760 0.089 (4) 16" x 20" x 2" ¾" 230 8.9 4 / 16
Belt 1,800 --1.2 1.0 - 1,760 0.089 (4) 16" x 20" x 2" ¾" 230 8.9 4 / 16
-------------
-------------
1 (11" x 10") VL44 x ⅞ AK66 x 1 / AX52
1 (11" x 10") VL44 x ⅞ AK66 x 1 / AX52
1 (11" x 10") VL44 x ⅞ AK66 x 1 / AX52
1 ⅓ - 1,075 22 / 4 4,200 18.7 2 / 20 0.062
1 ⅓ - 1,075 22 / 4 4,200 18.7 2 / 20 0.062
1 ⅓ - 1,075 22 / 4 4,200 18.7 2 / 20 0.068
1 ⅓ - 1,075 22 / 4 4,200 18.7 2 / 20 0.068
1 ⅓ - 1,075 22 / 4 4,200 18.7 2 / 20 0.068
1 / Scroll / Single 26.4 / 134.0
1 / Scroll / Single 16.0 / 110.0
1 / Scroll / Single 16 .0/ 110.0
1 / Scroll / Single 7.8 / 52
1 / Scroll / Single 5.7 / 38.9
208/230-1-60 1 / 6.9 0.9" ⅓ / 2.0 40.2 60 1.125" ½" 650 675
208/230-3-60 1 / 6.9 0.9" ⅓ / 2.3 29 45 1.125" ½" 650 675
208/230-3-60 1.0 / 3.0 1.0 ⅓ / 2.3 25.5 40 1.125 ½" 650 675
460-3-60 1.0 / 1.5 1.0 ⅓ / 1.1 12.3 20 1.125 ½" 650 675
575-3-60 1.0 / 1.2 1.0 ⅓ / 0.9 9.2 15 1.125 ½" 650 675
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed.
6
www.daikinac.com
SS-DSH3
SS-DSH3
www.daikinac.com
59 36.7 0.74 19 2.37 6.7 230 111 35.6 0.71 19 2.35 6.6 228 110 32.8 0.68 20 2.30 6.5 221 107
37.3 0.84 21 2.39 6.7 232 112 36.2 0.80 22 2.37 6.7 230 111 33.4 0.77 23 2.32 6.5 223 108
Airflow MBh S/T Delta T 1350 KW AMPS HI PR LO PR MBh S/T Delta T KW 1200 AMPS HI PR LO PR MBh S/T Delta T KW 1050 AMPS HI PR LO PR
MBh S/T Delta T 1350 KW AMPS HI PR LO PR MBh S/T Delta T 1200 KW AMPS HI PR LO PR MBh S/T Delta T 1050 KW AMPS HI PR LO PR
38.4 0.75 20 2.44 6.9 250 119 37.3 0.72 21 2.42 6.8 247 118 34.4 0.69 21 2.36 6.6 240 115
63 38.0 0.62 16 2.42 6.8 247 118 36.9 0.59 17 2.40 6.8 245 117 34.0 0.57 17 2.35 6.6 238 113 41.5 0.57 16 2.51 7.1 264 130 40.3 0.54 17 2.49 7.0 261 129 37.2 0.52 17 2.44 6.8 254 125
67 41.6 0.43 12 2.49 7.0 261 129 40.4 0.41 13 2.47 6.9 259 128 37.3 0.39 13 2.42 6.8 251 124 44.6 0.37 11 2.59 7.3 275 139 43.3 0.35 12 2.57 7.2 273 137 40.0 0.34 12 2.51 7.1 264 133
71 36.4 0.87 22 2.57 7.2 261 119 35.3 0.83 23 2.55 7.1 258 117 32.6 0.80 23 2.49 7.0 250 114
59 35.8 0.77 19 2.55 7.1 258 117 34.8 0.73 20 2.53 7.1 255 116 32.1 0.71 20 2.47 6.9 248 113
IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports.
75
70
IDB
65
37.5 0.78 20 2.62 7.4 280 126 36.4 0.74 21 2.60 7.3 278 125 33.6 0.72 21 2.54 7.1 269 121
63 37.1 0.64 16 2.60 7.3 278 125 36.0 0.61 17 2.58 7.2 275 124 33.3 0.59 17 2.52 7.1 267 120
75
40.6 0.59 16 2.70 7.6 296 138 39.4 0.56 17 2.68 7.5 293 136 36.4 0.54 17 2.62 7.3 284 132
67 40.7 0.44 12 2.68 7.5 293 136 39.5 0.42 13 2.66 7.5 290 135 36.4 0.41 13 2.59 7.3 282 131 43.5 0.38 11 2.78 7.8 309 147 42.3 0.36 12 2.76 7.8 306 145 39.0 0.35 12 2.70 7.6 297 141
71 35.5 0.90 22 2.72 7.8 296 123 34.5 0.85 23 2.70 7.7 293 122 31.8 0.82 23 2.64 7.5 285 118
59 34.9 0.79 19 2.70 7.7 293 122 33.9 0.75 20 2.68 7.6 291 121 31.3 0.72 20 2.61 7.4 282 117 36.6 0.80 20 2.78 7.9 319 131 35.5 0.76 21 2.76 7.9 316 130 32.8 0.74 21 2.69 7.7 306 126
42.5 0.39 11 2.96 8.5 351 152 41.3 0.37 12 2.93 8.4 348 151 38.1 0.36 12 2.86 8.2 337 146
34.7 0.92 22 2.86 8.3 338 129 33.7 0.88 23 2.83 8.2 334 128 31.1 0.85 23 2.77 8.0 324 124
35.7 0.83 20 2.92 8.4 363 138 34.7 0.79 21 2.90 8.4 360 136 32.0 0.76 21 2.83 8.2 349 132
38.6 0.63 16 3.01 8.7 384 150 37.5 0.60 17 2.99 8.6 380 149 34.6 0.58 17 2.91 8.4 368 144 Shaded area reflects ACCA (TVA) conditions
39.6 0.61 16 2.86 8.2 337 143 38.5 0.58 17 2.84 8.1 334 142 35.5 0.56 17 2.77 7.9 324 137
Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 36.2 39.7 34.1 35.3 38.7 0.66 0.46 0.81 0.68 0.47 16 12 19 16 12 2.76 2.84 2.83 2.89 2.99 7.9 8.1 8.2 8.4 8.6 316 333 334 360 380 130 142 128 136 149 35.2 38.5 33.1 34.3 37.6 0.63 0.43 0.78 0.65 0.45 17 13 20 17 13 2.73 2.82 2.81 2.87 2.96 7.8 8.0 8.1 8.3 8.6 313 330 331 356 376 128 140 127 135 147 30.6 31.7 34.7 32.5 35.6 0.61 0.42 0.75 0.62 0.43 17 13 20 17 13 2.67 2.75 2.74 2.80 2.89 7.6 7.8 7.9 8.1 8.3 303 320 321 345 365 125 136 123 131 143 41.5 0.40 11 3.11 9.0 400 160 40.3 0.38 12 3.08 8.9 396 158 37.2 0.37 12 3.01 8.7 384 154
71 32.9 0.96 22 2.97 8.7 380 136 32.0 0.91 22 2.95 8.7 376 134 29.5 0.88 23 2.88 8.4 365 130
59 32.4 0.84 19 2.95 8.7 376 134 31.4 0.80 19 2.93 8.6 372 133 29.0 0.78 20 2.86 8.4 361 129 36.7 0.65 16 3.13 9.2 432 157 35.6 0.62 17 3.11 9.1 427 156 32.9 0.60 17 3.03 8.9 415 151
67 36.8 0.49 12 3.11 9.1 427 156 35.7 0.47 13 3.08 9.1 423 154 33.0 0.45 13 3.01 8.8 410 150 39.4 0.42 11 3.24 9.5 450 168 38.3 0.40 12 3.21 9.5 446 166 35.3 0.38 12 3.13 9.2 432 161
71 30.5 0.97 20 3.07 9.2 420 140 29.6 0.92 21 3.05 9.1 416 139 27.3 0.89 21 2.98 8.9 403 135
59 30.0 0.85 17 3.05 9.1 415 139 29.1 0.81 18 3.02 9.1 411 137 26.9 0.78 18 2.95 8.8 399 133 31.4 0.87 19 3.14 9.4 452 149 30.5 0.83 19 3.12 9.4 447 148 28.2 0.80 20 3.04 9.1 434 143
63 31.1 0.71 15 3.11 9.4 447 148 30.2 0.68 16 3.09 9.3 443 146 27.9 0.65 16 3.01 9.0 429 142 34.0 0.65 15 3.24 9.7 477 163 33.0 0.62 16 3.22 9.6 472 161 30.5 0.60 16 3.14 9.4 458 156
67 34.1 0.49 11 3.22 9.6 472 161 33.1 0.47 12 3.19 9.6 467 160 30.5 0.45 12 3.11 9.3 453 155
115
36.5 0.42 10 3.35 10.1 497 173 35.4 0.40 11 3.32 10.0 492 172 32.7 0.39 11 3.24 9.7 478 167
71 -
kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors)
33.9 0.86 20 3.04 8.9 409 144 32.9 0.82 21 3.01 8.9 405 143 30.4 0.79 21 2.94 8.6 393 139
63 33.6 0.70 16 3.01 8.9 405 143 32.6 0.67 17 2.99 8.8 401 141 30.1 0.65 17 2.92 8.6 389 137
105
Expanded Cooling Data — 3 Tons
7
8
www.daikinac.com
59 37.9 0.92 24 2.41 6.8 235 113 36.8 0.88 25 2.39 6.7 232 112 34.0 0.85 25 2.34 6.6 225 109
38.6 0.97 25 2.43 6.8 237 114 37.5 0.92 27 2.41 6.8 235 113 34.6 0.89 27 2.35 6.6 228 110
Airflow MBh S/T Delta T 1350 KW AMPS HI PR LO PR MBh S/T Delta T 1200 KW AMPS HI PR LO PR MBh S/T Delta T 1050 KW AMPS HI PR LO PR
MBh S/T Delta T 1350 KW AMPS HI PR LO PR MBh S/T Delta T 1200 KW AMPS HI PR LO PR MBh S/T Delta T 1050 KW AMPS HI PR LO PR
39.3 0.93 25 2.48 7.0 255 122 38.2 0.89 26 2.46 6.9 252 121 35.3 0.86 27 2.40 6.7 245 117
63 38.8 0.87 23 2.46 6.9 252 121 37.6 0.83 24 2.44 6.9 250 119 34.7 0.80 24 2.38 6.7 242 116
41.2 0.84 24 2.55 7.2 269 133 40.0 0.80 25 2.53 7.1 267 132 36.9 0.78 25 2.47 6.9 259 128
67 41.4 0.71 20 2.53 7.1 267 132 40.2 0.67 21 2.51 7.1 264 130 37.1 0.65 21 2.45 6.9 256 126 44.0 0.68 20 2.63 7.4 281 142 42.7 0.65 21 2.61 7.4 278 140 39.4 0.63 22 2.55 7.2 270 136
71 44.3 0.53 16 2.61 7.4 278 140 43.0 0.50 17 2.59 7.3 275 139 39.7 0.48 17 2.53 7.1 267 135 37.7 1.00 26 2.61 7.3 266 121 36.6 0.96 27 2.59 7.3 263 120 33.8 0.92 27 2.53 7.1 255 116
59 37.1 0.96 24 2.59 7.3 263 120 36.0 0.91 25 2.57 7.2 261 119 33.2 0.88 26 2.51 7.0 253 115
IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports.
85
80
IDB
65
38.4 0.97 25 2.66 7.5 286 129 37.3 0.92 26 2.64 7.4 283 127 34.4 0.89 27 2.58 7.2 275 124
63 37.9 0.90 23 2.64 7.4 283 127 36.8 0.86 24 2.62 7.4 281 126 33.9 0.83 25 2.56 7.2 272 122
75
40.3 0.87 24 2.74 7.7 302 140 39.1 0.83 25 2.72 7.6 299 139 36.1 0.80 25 2.66 7.5 290 135
67 40.5 0.73 20 2.72 7.6 299 139 39.3 0.70 21 2.70 7.6 296 138 36.3 0.67 21 2.64 7.4 287 134 42.9 0.71 21 2.83 8.0 315 150 41.7 0.68 22 2.81 7.9 312 148 38.5 0.65 22 2.74 7.7 303 144
71 43.2 0.55 16 2.81 7.9 312 148 42.0 0.52 17 2.78 7.8 309 147 38.8 0.50 17 2.72 7.6 300 142 36.8 1.00 25 2.76 7.9 302 126 35.7 0.98 27 2.74 7.8 299 124 33.0 0.95 27 2.68 7.6 290 121
59 36.2 1.00 25 2.74 7.8 299 124 35.1 0.94 25 2.72 7.8 296 123 32.4 0.90 26 2.66 7.6 288 120 37.5 0.99 25 2.82 8.1 325 134 36.4 0.95 26 2.80 8.0 322 132 33.6 0.91 27 2.73 7.8 313 128
41.9 0.73 21 3.00 8.6 358 155 40.7 0.69 22 2.98 8.5 355 154 37.6 0.67 22 2.91 8.3 344 149
35.9 1.00 24 2.90 8.4 344 132 34.9 1.00 27 2.88 8.3 341 131 32.2 0.98 28 2.81 8.1 331 127
36.6 1.00 25 2.97 8.6 371 140 35.5 0.98 27 2.94 8.5 367 139 32.8 0.94 27 2.87 8.3 356 135 Shaded area reflects AHRI conditions
39.3 0.90 24 2.91 8.3 344 146 38.1 0.86 25 2.89 8.3 340 145 35.2 0.82 25 2.82 8.0 330 140
38.3 0.93 24 3.06 8.8 391 153 37.2 0.88 25 3.04 8.8 388 152 34.4 0.85 26 2.96 8.5 376 147
Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 37.0 39.5 42.2 35.3 36.1 38.5 0.92 0.75 0.56 1.00 0.95 0.77 23 20 16 24 23 20 2.80 2.89 2.98 2.88 2.94 3.04 8.0 8.3 8.5 8.3 8.5 8.8 322 340 355 341 367 388 132 145 154 131 139 152 35.9 38.3 41.0 34.3 35.0 37.4 0.88 0.71 0.53 0.97 0.91 0.74 24 21 17 25 24 21 2.78 2.86 2.96 2.86 2.92 3.01 7.9 8.2 8.5 8.3 8.4 8.7 319 337 351 338 363 384 131 143 152 129 138 150 33.1 35.4 37.8 31.6 32.3 34.5 0.85 0.69 0.52 0.93 0.87 0.71 25 21 17 26 25 22 2.71 2.80 2.89 2.79 2.85 2.94 7.7 8.0 8.2 8.0 8.2 8.5 309 327 341 328 352 372 127 139 148 126 134 146 40.9 0.75 21 3.16 9.2 408 163 39.7 0.72 22 3.13 9.1 404 162 36.6 0.69 22 3.06 8.8 392 157
71 41.2 0.58 16 3.13 9.1 404 162 40.0 0.55 17 3.11 9.0 400 160 36.9 0.53 17 3.03 8.8 388 155 34.1 1.00 23 3.02 8.9 387 138 33.1 1.00 25 3.00 8.8 384 137 30.6 1.00 27 2.93 8.6 372 133
59 33.5 1.00 23 3.00 8.8 384 137 32.5 1.00 25 2.97 8.7 380 136 30.0 0.97 25 2.90 8.5 368 132 36.4 0.96 24 3.19 9.4 440 161 35.4 0.92 25 3.16 9.3 436 159 32.6 0.88 25 3.08 9.1 423 154
67 36.6 0.80 20 3.16 9.3 436 159 35.5 0.77 21 3.14 9.2 432 158 32.8 0.74 21 3.06 9.0 419 153 38.9 0.78 21 3.29 9.7 459 171 37.7 0.74 21 3.26 9.6 455 169 34.8 0.72 22 3.18 9.4 441 164
71 39.1 0.60 16 3.26 9.6 455 169 38.0 0.57 17 3.24 9.5 450 168 35.1 0.55 17 3.16 9.3 437 163 31.6 1.00 22 3.12 9.4 428 143 30.7 1.00 24 3.10 9.3 424 142 28.3 1.00 25 3.02 9.1 411 137
59 31.1 1.00 21 3.10 9.3 424 142 30.2 1.00 23 3.07 9.2 420 140 27.8 0.98 24 3.00 9.0 407 136 32.2 1.00 22 3.19 9.6 461 152 31.3 1.00 24 3.17 9.5 456 151 28.9 0.99 25 3.09 9.3 442 146
63 31.7 1.00 22 3.17 9.5 456 151 30.8 0.95 22 3.14 9.4 452 149 28.4 0.92 23 3.06 9.2 438 145 33.7 0.97 22 3.30 9.9 487 166 32.8 0.92 23 3.27 9.8 482 165 30.2 0.89 24 3.19 9.6 467 160
67 33.9 0.81 19 3.27 9.8 482 165 32.9 0.77 19 3.24 9.7 477 163 30.4 0.74 20 3.16 9.5 463 158
115
36.0 0.79 19 3.40 10.3 507 177 34.9 0.75 20 3.38 10.2 502 175 32.3 0.72 20 3.29 9.9 487 170
71 36.2 0.61 15 3.38 10.2 502 175 35.2 0.58 16 3.35 10.1 497 174 32.5 0.56 16 3.27 9.8 483 168
kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors)
34.8 1.00 24 3.09 9.1 417 147 33.8 1.00 26 3.06 9.0 413 146 31.2 0.98 27 2.99 8.8 400 141
63 34.3 1.00 23 3.06 9.0 413 146 33.3 0.94 24 3.04 8.9 409 144 30.7 0.91 24 2.96 8.7 397 140
105
Expanded Cooling Data — 3 Tons (cont.)
SS-DSH3
SS-DSH3
www.daikinac.com
59 46.3 0.77 18 3.09 8.0 241 112 44.9 0.73 19 3.07 7.9 239 111 41.5 0.71 19 3.00 7.7 232 107
47.1 0.87 21 3.12 8.1 244 113 45.7 0.83 22 3.09 8.0 241 112 42.2 0.80 22 3.02 7.8 234 108
Airflow MBh S/T Delta T 1800 KW AMPS HI PR LO PR MBh S/T Delta T 1600 KW AMPS HI PR LO PR MBh S/T Delta T 1400 KW AMPS HI PR LO PR
MBh S/T Delta T 1800 KW AMPS HI PR LO PR MBh S/T Delta T 1600 KW AMPS HI PR LO PR MBh S/T Delta T 1400 KW AMPS HI PR LO PR
48.5 0.78 19 3.18 8.2 262 120 47.0 0.75 20 3.15 8.2 260 119 43.4 0.72 21 3.08 8.0 252 115
63 48.0 0.64 16 3.15 8.2 260 119 46.6 0.61 16 3.13 8.1 257 118 43.0 0.59 17 3.06 7.9 249 114
52.4 0.59 16 3.27 8.5 277 131 50.9 0.56 17 3.25 8.4 274 130 47.0 0.54 17 3.17 8.2 266 126
67 52.5 0.45 12 3.25 8.4 274 130 51.0 0.42 12 3.22 8.3 272 128 47.1 0.41 13 3.15 8.1 263 125 56.3 0.38 11 3.37 8.8 289 140 54.6 0.36 11 3.35 8.7 286 138 50.4 0.35 12 3.27 8.5 277 134
71 46.0 0.91 21 3.34 8.7 274 119 44.6 0.86 22 3.32 8.6 271 118 41.2 0.83 23 3.24 8.4 263 115
59 45.2 0.80 18 3.32 8.6 271 118 43.9 0.76 19 3.29 8.5 268 117 40.5 0.73 20 3.22 8.3 260 113
IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports.
75
70
IDB
65
47.3 0.81 20 3.41 8.9 294 127 45.9 0.77 20 3.38 8.8 291 126 42.4 0.75 21 3.31 8.6 283 122
63 46.8 0.67 16 3.38 8.8 291 126 45.5 0.64 17 3.36 8.7 289 124 42.0 0.61 17 3.28 8.5 280 121
75
51.2 0.61 16 3.51 9.1 311 138 49.7 0.59 17 3.49 9.0 308 137 45.9 0.56 17 3.41 8.8 299 133
67 51.3 0.46 12 3.49 9.0 308 137 49.8 0.44 13 3.46 9.0 305 136 46.0 0.42 13 3.38 8.7 296 132 55.0 0.39 11 3.62 9.4 324 147 53.4 0.38 12 3.60 9.4 321 146 49.3 0.36 12 3.51 9.1 311 142
71 44.9 0.93 21 3.54 9.4 311 124 43.6 0.89 22 3.51 9.3 308 123 40.2 0.85 23 3.43 9.0 299 119
59 44.1 0.82 18 3.51 9.3 308 123 42.8 0.78 19 3.49 9.2 305 121 39.5 0.75 20 3.41 9.0 296 118 46.2 0.83 20 3.62 9.6 335 132 44.9 0.79 20 3.59 9.5 331 131 41.4 0.76 21 3.50 9.2 322 127
53.7 0.40 11 3.84 10.2 369 153 52.1 0.39 12 3.81 10.1 365 152 48.1 0.37 12 3.72 9.9 354 147
43.8 0.96 21 3.72 10.0 354 130 42.5 0.91 22 3.69 9.9 351 129 39.2 0.88 23 3.60 9.6 340 125
45.1 0.86 20 3.80 10.2 381 138 43.8 0.82 21 3.77 10.1 378 137 40.4 0.79 21 3.68 9.8 366 133
48.8 0.65 16 3.91 10.5 403 151 47.4 0.62 17 3.88 10.4 399 150 43.7 0.60 17 3.79 10.1 387 145 Shaded area reflects ACCA (TVA) conditions
50.0 0.63 16 3.73 9.9 354 144 48.5 0.60 17 3.70 9.8 350 143 44.8 0.58 17 3.61 9.5 340 138
Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 45.7 50.1 43.0 44.6 48.9 0.68 0.47 0.84 0.70 0.49 16 12 19 16 12 3.59 3.70 3.69 3.77 3.88 9.5 9.8 9.9 10.1 10.4 331 350 351 377 399 131 142 129 137 150 44.4 48.6 41.8 43.3 47.5 0.65 0.45 0.80 0.67 0.47 17 13 19 17 13 3.56 3.67 3.66 3.74 3.85 9.4 9.7 9.8 10.0 10.3 328 346 347 374 395 129 141 128 136 148 41.0 44.9 38.6 40.0 43.8 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 3.48 3.58 3.57 3.65 3.76 9.2 9.4 9.5 9.7 10.1 318 336 337 363 383 125 137 124 132 144 52.4 0.42 11 4.04 10.9 420 161 50.8 0.40 12 4.01 10.8 416 159 46.9 0.38 12 3.91 10.5 403 155
71 41.6 1.00 21 3.87 10.6 399 136 40.4 0.95 22 3.84 10.5 395 135 37.3 0.92 22 3.75 10.2 383 131
59 40.9 0.88 18 3.84 10.5 395 135 39.7 0.84 19 3.81 10.4 391 134 36.6 0.81 19 3.72 10.1 379 130 46.3 0.67 16 4.07 11.1 453 158 45.0 0.64 17 4.04 11.0 449 157 41.5 0.62 17 3.94 10.8 435 152
67 46.4 0.51 12 4.04 11.0 448 157 45.1 0.48 13 4.01 10.9 444 155 41.6 0.47 13 3.91 10.7 431 151 49.7 0.43 11 4.21 11.5 472 169 48.3 0.41 11 4.17 11.4 468 167 44.6 0.40 12 4.07 11.1 454 162
71 38.5 1.00 20 4.00 11.1 440 141 37.4 0.96 21 3.96 11.0 436 140 34.5 0.92 21 3.87 10.8 423 136
59 37.9 0.88 17 3.96 11.0 436 140 36.8 0.84 18 3.93 10.9 432 138 33.9 0.81 18 3.84 10.7 419 134 39.7 0.90 18 4.08 11.4 474 150 38.5 0.86 19 4.05 11.3 469 149 35.5 0.83 19 3.95 11.0 455 144
63 39.3 0.74 15 4.05 11.3 469 149 38.1 0.70 15 4.02 11.2 465 147 35.2 0.68 16 3.92 10.9 451 143 42.9 0.68 15 4.21 11.8 501 164 41.7 0.65 16 4.18 11.7 496 162 38.5 0.63 16 4.08 11.4 481 157
67 43.0 0.51 11 4.18 11.7 495 162 41.8 0.49 12 4.14 11.6 491 161 38.5 0.47 12 4.04 11.3 476 156
115
46.1 0.44 10 4.35 12.2 522 175 44.7 0.42 11 4.31 12.1 517 173 41.3 0.40 11 4.21 11.8 501 168
71 -
kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors)
42.8 0.89 19 3.95 10.8 429 145 41.6 0.85 20 3.92 10.7 425 144 38.4 0.82 21 3.82 10.4 412 139
63 42.4 0.73 16 3.92 10.7 425 144 41.2 0.70 16 3.89 10.6 420 142 38.0 0.67 17 3.79 10.3 408 138
105
Expanded Cooling Data — 4 Tons
9
10
www.daikinac.com
59 47.9 0.96 23 3.14 8.1 246 114 46.5 0.91 24 3.12 8.1 244 113 42.9 0.88 25 3.05 7.9 236 109
48.7 1.00 25 3.16 8.2 249 115 47.3 0.96 26 3.14 8.1 246 114 43.7 0.92 27 3.07 7.9 239 111
Airflow MBh S/T Delta T 1800 KW AMPS HI PR LO PR MBh S/T Delta T 1600 KW AMPS HI PR LO PR MBh S/T Delta T 1400 KW AMPS HI PR LO PR
MBh S/T Delta T 1800 KW AMPS HI PR LO PR MBh S/T Delta T 1600 KW AMPS HI PR LO PR MBh S/T Delta T 1400 KW AMPS HI PR LO PR
49.7 0.97 25 3.23 8.4 268 122 48.2 0.93 26 3.20 8.3 265 121 44.5 0.89 26 3.13 8.1 257 118
63 48.9 0.90 22 3.20 8.3 265 121 47.5 0.86 23 3.18 8.2 262 120 43.9 0.83 24 3.11 8.0 255 116
52.0 0.88 23 3.32 8.6 283 134 50.5 0.84 24 3.30 8.6 280 132 46.6 0.81 25 3.22 8.3 271 128
67 52.3 0.73 20 3.30 8.6 280 132 50.8 0.70 20 3.27 8.5 277 131 46.9 0.67 21 3.20 8.3 269 127 55.5 0.71 20 3.42 8.9 295 142 53.9 0.68 21 3.40 8.9 292 141 49.7 0.65 21 3.32 8.6 283 137
71 55.9 0.55 16 3.40 8.9 292 141 54.3 0.52 16 3.37 8.8 289 140 50.1 0.50 17 3.30 8.6 280 135 47.6 1.00 24 3.39 8.8 279 122 46.2 0.99 26 3.37 8.7 276 120 42.7 0.96 27 3.29 8.5 268 117
59 46.8 1.00 24 3.37 8.7 276 120 45.4 0.95 25 3.34 8.7 274 119 41.9 0.91 25 3.27 8.4 265 116
IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports.
85
80
IDB
65
48.5 1.00 25 3.46 9.0 300 129 47.1 0.96 26 3.44 8.9 297 128 43.5 0.92 26 3.36 8.7 288 124
63 47.8 0.93 23 3.44 8.9 297 128 46.4 0.89 24 3.41 8.9 294 127 42.8 0.86 24 3.33 8.6 286 123
75
50.8 0.91 24 3.57 9.3 317 141 49.3 0.87 25 3.54 9.2 314 140 45.5 0.83 25 3.46 9.0 305 136
67 51.1 0.76 20 3.54 9.2 314 140 49.6 0.72 21 3.51 9.1 311 138 45.8 0.70 21 3.43 8.9 302 134 54.2 0.74 20 3.68 9.6 331 150 52.6 0.70 21 3.65 9.5 327 149 48.6 0.68 22 3.57 9.3 318 145
71 54.6 0.57 16 3.65 9.5 327 149 53.0 0.54 16 3.62 9.4 324 148 48.9 0.52 17 3.54 9.2 315 143 46.5 1.00 24 3.60 9.5 317 126 45.1 1.00 26 3.57 9.4 314 125 41.6 0.98 27 3.49 9.2 305 121
59 45.7 1.00 23 3.57 9.4 314 125 44.3 0.97 25 3.54 9.4 311 124 40.9 0.94 25 3.46 9.1 302 120 47.4 1.00 24 3.67 9.7 342 135 46.0 0.98 26 3.64 9.6 338 133 42.4 0.95 26 3.56 9.4 328 129
52.9 0.76 20 3.91 10.4 376 156 51.4 0.72 21 3.88 10.3 372 155 47.4 0.69 22 3.78 10.0 361 150
45.3 1.00 23 3.78 10.1 361 133 44.0 1.00 25 3.75 10.0 358 131 40.6 1.00 27 3.66 9.8 347 128
46.2 1.00 24 3.86 10.4 389 141 44.9 1.00 26 3.83 10.3 385 140 41.4 0.98 27 3.73 10.0 374 136 Shaded area reflects AHRI conditions
49.6 0.93 24 3.79 10.0 361 147 48.2 0.89 25 3.76 9.9 357 145 44.5 0.86 25 3.67 9.7 346 141
48.4 0.96 24 3.98 10.7 411 154 47.0 0.92 25 3.95 10.6 407 153 43.4 0.88 25 3.85 10.3 395 148
Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.7 49.9 53.3 44.6 45.5 48.6 0.96 0.78 0.58 1.00 1.00 0.80 23 20 16 23 23 20 3.64 3.76 3.88 3.75 3.83 3.95 9.6 9.9 10.3 10.0 10.3 10.6 338 357 372 358 385 407 133 145 155 131 140 153 45.3 48.4 51.7 43.3 44.2 47.2 0.91 0.74 0.55 1.00 0.94 0.77 24 21 16 25 24 21 3.62 3.73 3.84 3.72 3.80 3.92 9.6 9.9 10.2 10.0 10.2 10.5 335 354 369 354 381 403 132 144 153 130 138 151 41.8 44.7 47.8 39.9 40.8 43.6 0.88 0.72 0.53 0.97 0.91 0.74 24 21 17 25 24 21 3.53 3.64 3.75 3.63 3.71 3.82 9.3 9.6 9.9 9.7 9.9 10.2 325 343 358 344 370 391 128 140 149 126 134 147 51.6 0.78 21 4.11 11.1 428 164 50.1 0.74 21 4.07 11.0 424 163 46.3 0.72 22 3.97 10.7 411 158
71 52.0 0.60 16 4.07 11.0 424 163 50.5 0.57 17 4.04 10.9 420 161 46.6 0.55 17 3.94 10.6 407 156 43.1 1.00 22 3.93 10.7 407 139 41.8 1.00 24 3.90 10.6 403 138 38.6 1.00 25 3.80 10.4 391 134
59 42.3 1.00 22 3.90 10.6 403 138 41.1 1.00 24 3.87 10.6 399 136 37.9 1.00 25 3.77 10.3 387 132 46.0 1.00 23 4.14 11.3 462 162 44.6 0.95 24 4.11 11.2 458 160 41.2 0.92 25 4.01 10.9 444 155
67 46.2 0.83 20 4.11 11.2 458 160 44.9 0.80 20 4.07 11.1 453 158 41.4 0.77 21 3.98 10.8 439 154 49.1 0.81 20 4.27 11.7 482 172 47.6 0.77 21 4.24 11.6 477 170 44.0 0.74 21 4.14 11.3 463 165
71 49.4 0.62 16 4.24 11.6 477 170 48.0 0.59 16 4.21 11.5 473 169 44.3 0.57 17 4.10 11.2 458 164 39.9 1.00 20 4.06 11.3 449 144 38.7 1.00 22 4.03 11.2 445 143 35.7 1.00 23 3.93 10.9 432 138
59 39.2 1.00 20 4.03 11.2 445 143 38.1 1.00 22 4.00 11.1 440 141 35.1 1.01 23 3.90 10.9 427 137 40.7 1.00 21 4.15 11.6 484 153 39.5 1.00 23 4.12 11.5 479 152 36.4 1.00 24 4.02 11.2 464 147
63 40.1 1.00 20 4.12 11.5 479 152 38.9 0.98 22 4.08 11.4 474 150 35.9 0.95 22 3.98 11.1 460 146 42.6 1.00 22 4.28 12.0 511 167 41.3 0.96 23 4.25 11.9 506 166 38.2 0.92 23 4.14 11.6 490 161
67 42.8 0.84 18 4.25 11.9 506 166 41.6 0.80 19 4.21 11.8 501 164 38.4 0.77 19 4.11 11.5 486 159
115
45.4 0.82 19 4.42 12.4 533 178 44.1 0.78 20 4.39 12.3 527 176 40.7 0.75 20 4.28 12.0 511 171
71 45.8 0.63 15 4.39 12.3 527 176 44.4 0.60 15 4.35 12.2 522 175 41.0 0.58 16 4.24 11.9 506 169
kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors)
43.9 1.00 22 4.01 11.0 438 148 42.6 1.00 24 3.98 10.9 433 147 39.3 1.00 26 3.89 10.6 420 142
63 43.3 1.00 22 3.98 10.9 433 147 42.0 0.98 24 3.95 10.8 429 145 38.8 0.94 24 3.85 10.5 416 141
105
Expanded Cooling Data — 4 Tons (cont.)
SS-DSH3
SS-DSH3
www.daikinac.com
59 59.2 0.75 18 3.97 10.3 238 112 57.4 0.72 19 3.94 10.2 236 111 53.0 0.69 19 3.85 9.9 228 107
60.2 0.85 21 4.00 10.3 240 113 58.4 0.82 22 3.97 10.3 238 112 53.9 0.79 22 3.88 10.0 231 108
Airflow MBh S/T Delta T 2250 KW AMPS HI PR LO PR MBh S/T Delta T 2000 KW AMPS HI PR LO PR MBh S/T Delta T 1750 KW AMPS HI PR LO PR
MBh S/T Delta T 2250 KW AMPS HI PR LO PR MBh S/T Delta T 2000 KW AMPS HI PR LO PR MBh S/T Delta T 1750 KW AMPS HI PR LO PR
61.9 0.76 19 4.08 10.6 259 120 60.1 0.73 20 4.05 10.5 256 119 55.5 0.70 21 3.96 10.2 248 115
63 61.3 0.63 16 4.05 10.5 256 119 59.5 0.60 16 4.02 10.4 253 118 54.9 0.58 17 3.93 10.1 246 114
67.0 0.58 16 4.20 10.9 273 131 65.1 0.55 17 4.17 10.8 270 130 60.1 0.53 17 4.07 10.5 262 126
67 67.2 0.44 12 4.17 10.8 270 130 65.2 0.42 12 4.14 10.7 268 128 60.2 0.40 13 4.04 10.4 260 125 72.0 0.37 11 4.33 11.3 285 140 69.9 0.36 11 4.30 11.2 282 138 64.5 0.34 12 4.20 10.9 274 134
71 58.8 0.89 21 4.29 11.1 270 119 57.0 0.84 22 4.26 11.0 267 118 52.7 0.81 23 4.16 10.7 259 115
59 57.8 0.78 18 4.26 11.0 267 118 56.1 0.74 19 4.22 10.9 264 117 51.8 0.72 19 4.13 10.7 256 113
IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports.
75
70
IDB
65
60.5 0.79 20 4.38 11.4 290 127 58.7 0.76 20 4.34 11.3 287 126 54.2 0.73 21 4.24 11.0 279 122
63 59.9 0.65 16 4.34 11.3 287 126 58.1 0.62 17 4.31 11.2 284 124 53.7 0.60 17 4.21 10.9 276 121
75
65.5 0.60 16 4.51 11.7 306 138 63.6 0.57 17 4.48 11.6 303 137 58.7 0.55 17 4.37 11.3 294 133
67 65.6 0.45 12 4.48 11.6 303 137 63.7 0.43 13 4.44 11.5 300 136 58.8 0.41 13 4.34 11.2 291 132 70.3 0.39 11 4.65 12.1 320 147 68.2 0.37 12 4.62 12.0 316 146 63.0 0.35 12 4.51 11.7 307 142
71 57.4 0.91 21 4.55 12.0 307 124 55.7 0.87 22 4.51 11.9 304 123 51.4 0.84 23 4.41 11.6 295 119
59 56.4 0.80 18 4.51 11.9 304 123 54.8 0.76 19 4.48 11.8 301 121 50.5 0.74 20 4.37 11.5 292 118 59.1 0.81 20 4.64 12.3 330 132 57.3 0.78 20 4.61 12.2 327 131 52.9 0.75 21 4.50 11.9 317 127
68.6 0.40 11 4.94 13.1 364 153 66.6 0.38 12 4.90 13.0 360 152 61.5 0.36 12 4.78 12.7 349 147
56.0 0.94 21 4.77 12.8 349 130 54.3 0.89 22 4.74 12.7 346 129 50.1 0.86 23 4.62 12.4 335 125
57.6 0.84 20 4.87 13.1 376 138 55.9 0.80 21 4.84 13.0 372 137 51.6 0.77 21 4.72 12.6 361 133
62.4 0.63 16 5.03 13.5 397 151 60.6 0.61 17 4.99 13.4 393 150 55.9 0.58 17 4.87 13.0 381 145 Shaded area reflects ACCA (TVA) conditions
63.9 0.62 16 4.79 12.7 349 144 62.1 0.59 17 4.75 12.6 345 143 57.3 0.57 17 4.64 12.2 335 138
Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 58.5 64.1 55.0 57.0 62.5 0.67 0.46 0.83 0.69 0.48 16 12 19 16 12 4.60 4.75 4.74 4.84 4.99 12.2 12.6 12.7 13.0 13.4 327 345 346 372 393 131 142 129 137 150 56.8 62.2 53.4 55.4 60.7 0.64 0.44 0.79 0.66 0.46 17 13 19 17 13 4.57 4.71 4.70 4.80 4.95 12.1 12.5 12.6 12.9 13.3 323 342 342 368 389 129 141 128 136 148 52.4 57.4 49.3 51.1 56.0 0.61 0.43 0.76 0.63 0.44 17 13 20 17 13 4.46 4.60 4.59 4.68 4.83 11.8 12.1 12.2 12.5 12.9 314 331 332 357 377 125 137 124 132 144 66.9 0.41 11 5.19 14.0 414 161 65.0 0.39 12 5.15 13.9 410 159 60.0 0.38 12 5.02 13.5 398 155
71 53.2 0.97 21 4.97 13.6 393 136 51.6 0.93 22 4.93 13.4 389 135 47.6 0.90 22 4.81 13.1 377 131
59 52.3 0.86 18 4.93 13.4 389 135 50.8 0.82 19 4.89 13.3 385 134 46.8 0.79 19 4.77 13.0 374 130 59.2 0.66 16 5.23 14.3 447 158 57.5 0.63 17 5.19 14.2 442 157 53.1 0.61 17 5.07 13.8 429 152
67 59.4 0.50 12 5.19 14.2 442 157 57.6 0.47 13 5.15 14.1 438 155 53.2 0.46 13 5.02 13.7 425 151 63.6 0.42 11 5.40 14.8 466 169 61.7 0.40 11 5.36 14.7 461 167 57.0 0.39 12 5.23 14.3 447 162
71 49.2 0.98 20 5.13 14.3 434 141 47.8 0.94 21 5.09 14.2 430 140 44.1 0.90 21 4.97 13.8 417 136
59 48.4 0.86 17 5.09 14.2 430 140 47.0 0.82 18 5.05 14.1 426 138 43.4 0.79 18 4.93 13.7 413 134 50.7 0.88 18 5.24 14.7 467 150 49.2 0.84 19 5.20 14.5 463 149 45.4 0.81 19 5.07 14.2 449 144
63 50.2 0.72 15 5.20 14.5 463 149 48.7 0.69 15 5.16 14.4 458 147 45.0 0.66 16 5.03 14.0 444 143 54.9 0.66 15 5.41 15.1 493 164 53.3 0.63 16 5.37 15.0 489 162 49.2 0.61 16 5.24 14.6 474 157
67 55.0 0.50 11 5.37 15.0 488 162 53.4 0.48 12 5.32 14.9 484 161 49.3 0.46 12 5.19 14.5 469 156
115
58.9 0.43 10 5.59 15.7 515 175 57.2 0.41 11 5.54 15.6 510 173 52.8 0.39 11 5.41 15.1 494 168
71 -
kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors)
54.7 0.87 19 5.07 13.9 423 145 53.1 0.83 20 5.03 13.8 419 144 49.1 0.80 21 4.91 13.4 406 139
63 54.2 0.72 16 5.03 13.8 419 144 52.6 0.68 16 4.99 13.6 414 142 48.6 0.66 17 4.87 13.3 402 138
105
Expanded Cooling Data — 5 Tons
11
12
www.daikinac.com
59 61.2 0.94 23 4.03 10.4 243 114 59.4 0.89 24 4.00 10.3 240 113 54.9 0.86 25 3.91 10.1 233 109
62.3 0.98 25 4.06 10.5 245 115 60.5 0.94 26 4.03 10.4 243 114 55.8 0.90 27 3.94 10.2 235 111
Airflow MBh S/T Delta T 2250 KW AMPS HI PR LO PR MBh S/T Delta T 2000 KW AMPS HI PR LO PR MBh S/T Delta T 1750 KW AMPS HI PR LO PR
MBh S/T Delta T 2250 KW AMPS HI PR LO PR MBh S/T Delta T 2000 KW AMPS HI PR LO PR MBh S/T Delta T 1750 KW AMPS HI PR LO PR
63.5 0.95 25 4.14 10.7 264 122 61.7 0.90 26 4.11 10.7 261 121 56.9 0.87 26 4.02 10.4 253 118
63 62.6 0.88 22 4.11 10.7 261 121 60.7 0.84 23 4.08 10.6 259 120 56.1 0.81 24 3.99 10.3 251 116
66.5 0.86 23 4.27 11.1 279 134 64.6 0.82 24 4.23 11.0 276 132 59.6 0.79 25 4.14 10.7 268 128
67 66.8 0.72 20 4.23 11.0 276 132 64.9 0.68 20 4.20 10.9 273 131 59.9 0.66 21 4.11 10.6 265 127 71.0 0.69 20 4.40 11.5 291 142 68.9 0.66 21 4.36 11.4 288 141 63.6 0.64 21 4.26 11.1 279 137
71 71.5 0.53 16 4.36 11.4 288 141 69.4 0.51 16 4.33 11.3 285 140 64.0 0.49 17 4.23 11.0 276 135 60.9 1.00 25 4.36 11.3 275 122 59.1 0.97 26 4.32 11.2 272 120 54.5 0.94 27 4.22 10.9 264 117
59 59.8 1.00 24 4.32 11.2 272 120 58.1 0.93 25 4.29 11.1 270 119 53.6 0.89 25 4.19 10.8 262 116
IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports.
85
80
IDB
65
62.0 0.98 25 4.45 11.6 296 129 60.2 0.94 26 4.41 11.5 293 128 55.6 0.90 26 4.31 11.2 284 124
63 61.1 0.91 23 4.41 11.5 293 128 59.3 0.87 24 4.38 11.4 290 127 54.8 0.84 24 4.28 11.1 282 123
75
65.0 0.89 24 4.58 11.9 313 141 63.1 0.85 25 4.55 11.8 310 140 58.2 0.82 25 4.44 11.5 300 136
67 65.3 0.74 20 4.55 11.8 310 140 63.4 0.71 21 4.51 11.7 306 138 58.5 0.68 21 4.41 11.4 297 134 69.3 0.72 20 4.73 12.3 326 150 67.3 0.69 21 4.69 12.2 323 149 62.1 0.66 22 4.58 11.9 313 145
71 69.8 0.55 16 4.69 12.2 323 149 67.8 0.53 16 4.65 12.1 320 148 62.5 0.51 17 4.54 11.8 310 143 59.4 1.00 24 4.62 12.2 313 126 57.7 1.00 26 4.58 12.1 310 125 53.2 0.96 27 4.48 11.8 301 121
59 58.4 1.00 24 4.58 12.1 310 125 56.7 0.95 25 4.55 12.0 307 124 52.3 0.92 25 4.44 11.7 298 120 60.6 1.00 25 4.72 12.5 337 135 58.8 0.96 26 4.68 12.4 333 133 54.3 0.93 26 4.57 12.1 323 129
67.7 0.74 20 5.02 13.4 371 156 65.7 0.70 21 4.98 13.2 367 155 60.6 0.68 22 4.86 12.9 356 150
58.0 1.00 24 4.85 13.0 356 133 56.3 1.00 26 4.81 12.9 353 131 51.9 0.99 27 4.70 12.6 342 128
59.1 1.00 24 4.95 13.3 384 141 57.4 0.99 26 4.91 13.2 380 140 52.9 0.96 27 4.80 12.9 368 136 Shaded area reflects AHRI conditions
63.4 0.91 24 4.86 12.9 356 147 61.6 0.87 25 4.82 12.8 352 145 56.8 0.84 25 4.71 12.5 341 141
61.9 0.94 24 5.11 13.7 405 154 60.1 0.90 25 5.07 13.6 401 153 55.4 0.86 25 4.95 13.3 389 148
Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 59.7 63.7 68.1 57.0 58.2 62.2 0.93 0.76 0.57 1.00 0.96 0.79 23 20 16 23 23 20 4.68 4.82 4.98 4.81 4.91 5.07 12.4 12.8 13.2 12.9 13.2 13.6 333 352 367 353 380 401 133 145 155 131 140 153 57.9 61.9 66.1 55.3 56.5 60.4 0.89 0.73 0.54 0.98 0.92 0.75 24 21 16 25 24 21 4.64 4.79 4.94 4.77 4.87 5.03 12.3 12.7 13.1 12.8 13.1 13.5 330 349 364 349 376 397 132 144 153 130 138 151 53.5 57.1 61.1 51.0 52.2 55.7 0.86 0.70 0.52 0.95 0.89 0.72 24 21 17 25 24 21 4.53 4.67 4.82 4.66 4.76 4.91 12.0 12.3 12.8 12.5 12.7 13.1 320 338 353 339 365 385 128 140 149 126 134 147 66.0 0.76 21 5.27 14.2 422 164 64.1 0.73 21 5.23 14.1 418 163 59.1 0.70 22 5.10 13.7 406 158
71 66.5 0.59 16 5.23 14.1 418 163 64.5 0.56 17 5.19 14.0 414 161 59.6 0.54 17 5.06 13.6 402 156 55.1 1.00 22 5.05 13.8 401 139 53.5 1.00 25 5.01 13.7 397 138 49.3 1.00 26 4.89 13.3 385 134
59 54.1 1.00 22 5.01 13.7 397 138 52.5 1.00 24 4.97 13.6 393 136 48.5 0.98 25 4.85 13.2 381 132 58.8 0.97 23 5.32 14.6 456 162 57.1 0.93 24 5.28 14.5 451 160 52.7 0.90 25 5.15 14.1 438 155
67 59.1 0.81 20 5.28 14.5 451 160 57.4 0.78 20 5.23 14.3 447 158 52.9 0.75 21 5.11 13.9 433 154 62.7 0.79 20 5.49 15.1 475 172 60.9 0.75 21 5.45 15.0 470 170 56.2 0.73 21 5.31 14.6 456 165
71 63.1 0.61 16 5.45 15.0 470 170 61.3 0.58 16 5.40 14.8 466 169 56.6 0.56 17 5.27 14.4 452 164 51.0 1.00 21 5.22 14.6 443 144 49.5 1.00 23 5.17 14.5 439 143 45.7 1.00 24 5.05 14.1 425 138
59 50.1 1.00 20 5.17 14.5 439 143 48.7 1.00 22 5.13 14.3 434 141 44.9 0.99 23 5.01 14.0 421 137 52.0 1.00 21 5.33 14.9 477 153 50.5 1.00 23 5.29 14.8 472 152 46.6 1.00 24 5.16 14.4 458 147
63 51.2 1.00 21 5.29 14.8 472 152 49.7 0.96 22 5.24 14.7 467 150 45.9 0.93 22 5.12 14.3 453 146 54.4 0.98 22 5.50 15.4 503 167 52.9 0.94 23 5.46 15.3 498 166 48.8 0.90 23 5.32 14.9 483 161
67 54.7 0.82 18 5.46 15.3 498 166 53.1 0.78 19 5.41 15.1 493 164 49.0 0.76 19 5.28 14.7 479 159
115
58.1 0.80 19 5.68 16.0 525 178 56.4 0.76 20 5.63 15.8 520 176 52.1 0.73 20 5.49 15.4 504 171
71 58.5 0.61 15 5.63 15.8 520 176 56.8 0.59 15 5.59 15.7 515 175 52.4 0.56 16 5.45 15.3 499 169
kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors)
56.1 1.00 23 5.15 14.1 431 148 54.5 1.00 25 5.11 14.0 427 147 50.3 0.99 26 4.99 13.6 414 142
63 55.3 1.00 23 5.11 14.0 427 147 53.7 0.95 24 5.07 13.9 423 145 49.5 0.92 24 4.95 13.5 410 141
105
Expanded Cooling Data — 5 Tons (cont.)
SS-DSH3
Airflow Data — 3 Tons
Standard Belt Drive — Down Shot ESP (" W.C.)
Turns Open 0
1
2
3
4
5
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
0.1
---
---
---
---
---
---
---
---
1358
0.32
1210
0.24
0.2
---
---
---
---
---
---
---
---
1203
0.29
1044
0.23
0.3
---
---
---
---
---
---
1209
0.34
1044
0.27
854
0.22
0.4
---
---
---
---
1320
0.34
1050
0.31
836
0.24
665
0.20
0.5
---
---
1317
0.37
1124
0.31
862
0.29
---
---
---
---
0.6
---
---
1154
0.34
930
0.28
675
0.25
---
---
---
---
0.7
1270
0.41
991
0.31
685
0.25
---
---
---
---
---
---
0.8
1091
0.37
807
0.28
---
---
---
---
---
---
---
---
0.9
905
0.34
633
0.25
---
---
---
---
---
---
---
---
1.0
660
0.29
---
---
---
---
---
---
---
---
---
---
High-Static Belt Drive — Down Shot ESP (" W.C.)
Turns Open 0
1
2
3
4
5
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
0.6
---
---
---
---
---
---
---
---
---
---
---
---
0.7
---
---
---
---
---
---
---
---
---
---
---
---
0.8
---
---
---
---
---
---
---
---
---
---
1240
0.44
0.9
---
---
---
---
---
---
---
---
---
---
1124
0.43
1.0
---
---
---
---
---
---
---
---
1225
0.48
965
0.39
1.1
---
---
---
---
---
---
1280
0.55
1063
0.44
804
0.37
1.2
---
---
---
---
---
---
1143
0.52
867
0.40
---
---
1.3
---
---
---
---
1268
0.59
963
0.48
651
0.36
---
---
1.4
---
---
1347
0.69
1127
0.55
766
0.43
---
---
---
---
1.5
---
---
1211
0.65
986
0.52
---
---
---
---
---
---
1.6
1290
0.73
1024
0.59
833
0.48
---
---
---
---
---
---
1.7
1152
0.69
837
0.55
---
---
---
---
---
---
---
---
1.8
1062
0.66
---
---
---
---
---
---
---
---
---
---
SS-DSH3
www.daikinac.com
13
Airflow Data — 3 Tons (cont.)
Standard Belt Drive — Horizontal ESP (" W.C.)
Turns Open 0
1
2
3
4
5
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
0.1
---
---
---
---
---
---
---
---
---
---
1375
0.28
0.2
---
---
---
---
---
---
---
---
1367
0.33
1186
0.21
0.3
---
---
---
---
---
---
1374
0.39
1186
0.31
971
---
0.4
---
---
---
---
---
---
1193
0.36
952
0.28
756
---
0.5
---
---
---
---
1277
0.36
980
0.34
718
0.26
---
---
0.6
---
---
1312
0.39
1056
0.33
767
0.31
---
---
---
---
0.7
---
---
1126
0.36
779
0.29
---
---
---
---
---
---
0.8
1240
0.43
917
0.33
---
---
---
---
---
---
---
---
0.9
1029
0.39
708
0.30
---
---
---
---
---
---
---
---
1.0
749
0.34
---
---
---
---
---
---
---
---
---
---
High-Static Belt Drive — Horizontal ESP (" W.C.)
14
Turns Open 0
1
2
3
4
5
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
0.6
---
---
---
---
---
---
---
---
---
---
---
---
0.7
---
---
---
---
---
---
---
---
---
---
---
---
0.8
---
---
---
---
---
---
---
---
---
---
1459
0.51
0.9
---
---
---
---
---
---
---
---
---
---
1322
0.50
1.0
---
---
---
---
---
---
---
---
1392
0.55
1136
0.46
1.1
---
---
---
---
---
---
1455
0.63
1208
0.51
947
0.43
1.2
---
---
---
---
---
---
1299
0.60
985
0.46
738
0.40
1.3
---
---
---
---
1409
0.65
1094
0.54
740
0.41
---
---
1.4
---
---
1480
0.76
1252
0.61
870
0.49
---
---
---
---
1.5
---
---
1331
0.71
1095
0.57
---
---
---
---
---
---
1.6
1418
0.80
1126
0.65
925
0.53
---
---
---
---
---
---
1.7
1266
0.75
920
0.60
---
---
---
---
---
---
---
---
1.8
1168
0.73
---
---
---
---
---
---
---
---
---
---
www.daikinac.com
SS-DSH3
Airflow Data — 3 Tons (cont.) Standard Direct Drive — Horizontal CFM
Static
Amps
Watts
RPM
Standard Direct Drive — Down Shot Speed Tap
CFM
Static
Amps
Watts
RPM
1280
0.1
1.54
360
755
1270
0.1
1.53
355
760
1215
0.2
1.5
345
800
1205
0.2
1.53
350
810
1145
0.3
1.46
335
830
1145
0.3
1.49
340
840
1080
0.4
1.42
325
870
1085
0.4
1.45
330
875
1005
0.5
1.37
310
895
1035
0.5
1.42
320
900
1485
0.1
1.98
460
840
1460
0.6
1.96
450
850
1410
0.2
1.92
440
870
1380
0.1
1.89
430
885
1335
0.3
1.86
425
900
1255
0.4
1.8
410
930
1170
0.5
1.75
400
1075
0.6
1.68
380
Low
1275
0.2
1.8
405
915
1175
0.3
1.73
400
950
950
1075
0.4
1.68
380
965
980
1005
0.5
1.63
370
1000
Med
945
0.7
1.6
360
1005
915
0.6
1.59
360
1015
1445
0.2
2.2
505
940
1445
0.7
2.2
500
950
1365
0.3
2.14
490
960
1340
0.3
2.13
480
975
1270
0.4
2.08
470
985
1275
0.4
2.07
465
1000
1180
0.5
2.02
460
1000
1175
0.5
2.02
455
1020
1050
0.6
1.92
435
1030
1040
0.6
1.92
430
1045
825
0.7
1.78
400
1055
830
0.7
1.78
395
1070
920
0.8
1.90
390
1067
922
0.8
1.90
386
1067
High
Speed Tap
Low
Med
High
See Notes below
Airflow Data — 4 Tons Standard Direct Drive — Horizontal CFM
Static
Amps
Watts
RPM
Standard Direct Drive — Down Shot Speed Tap
CFM
Static
Amps
Watts
RPM
1570
0.1
2.09
490
905
1548
0.1
2.03
480
930
1520
0.2
2.06
480
920
1500
0.2
2.00
470
945
1445
0.3
1.95
460
945
1425
0.3
1.89
450
970
1375
0.4
1.89
440
970
1353
0.4
1.83
430
995
Low
1295
0.5
1.81
425
995
1273
0.5
175
415
1020
1715
0.1
2.39
560
975
1660
0.1
2.31
540
1020
1655
0.2
2.32
545
985
1625
0.2
2.25
530
1035
1580
0.3
2.24
525
1005
1565
0.3
2.19
515
1040
1500
0.4
2.16
505
1020
1405
0.5
2.09
490
1035
Med
1485
0.4
2.12
505
1050
1405
0.5
2.12
500
1055
1305
0.6
2.00
465
1050
1285
0.6
1.98
465
1060
1200
0.7
1.92
440
1065
1200
0.7
1.93
440
1070
1839
0.1
2.77
650
1030
1825
0.1
2.65
620
1045
1770
0.2
2.70
630
1040
1745
0.2
2.55
600
1060
1696
0.3
2.62
610
1050
1670
0.3
2.53
590
1065
1611
0.4
2.53
590
1060
1585
0.4
2.46
575
1070
High
1510
0.5
2.44
560
1070
1480
0.5
2.37
550
1080
1418
0.6
2.36
540
1085
1405
0.6
2.31
535
1090
Speed Tap
Low
Med
High
Notes • Assumes dry coil with filter in place; SCFM correction for wet coil = 4% • Five-ton models are shipped from the factory with speed tap set on T4.
SS-DSH3
www.daikinac.com
15
Airflow Data — 4 Tons
Standard Belt Drive — Down Shot ESP (" W.C.)
Turns Open 0
1
2
3
4
5
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
0.1
---
---
---
---
---
---
---
---
1721
0.42
1588
0.34
0.2
---
---
---
---
---
---
1756
0.47
1582
0.39
1449
0.33
0.3
---
---
---
---
1736
0.52
1604
0.44
1437
0.37
1282
0.31
0.4
---
---
1765
0.54
1601
0.49
1452
0.41
1286
0.34
1109
0.28
0.5
1802
0.53
1653
0.51
1458
0.46
1306
0.38
1114
0.32
---
---
0.6
1701
0.56
1525
0.48
1314
0.43
1152
0.36
---
---
---
---
0.7
1593
0.54
1406
0.46
1160
0.40
956
0.33
---
---
---
---
0.8
1446
0.51
1247
0.43
982
0.36
---
---
---
---
---
---
0.9
1317
0.48
1072
0.39
---
---
---
---
---
---
---
---
1.0
1145
0.44
---
---
---
---
---
---
---
---
---
---
High Static Belt Drive — Down Shot ESP (" W.C.)
16
Turns Open 0
1
2
3
4
5
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
0.6
---
---
---
---
---
---
---
---
---
---
1634
0.52
0.7
---
---
---
---
---
---
---
---
1705
0.59
1520
0.49
0.8
---
---
---
---
---
---
1753
0.64
1576
0.56
1378
0.47
0.9
---
---
---
---
---
---
1644
0.61
1447
0.52
1237
0.43
1.0
---
---
---
---
1727
0.69
1535
0.58
1294
0.49
1070
0.40
1.1
---
---
---
---
1605
0.66
1392
0.54
1144
0.45
---
---
1.2
---
---
1745
0.76
1483
0.62
1232
0.50
974
0.42
---
---
1.3
1783
0.87
1586
0.71
1331
0.58
1068
0.46
---
---
---
---
1.4
1658
0.83
1427
0.66
1177
0.53
---
---
---
---
---
---
1.5
1533
0.78
1296
0.62
1019
0.50
---
---
---
---
---
---
1.6
1387
0.73
1123
0.57
---
---
---
---
---
---
---
---
1.7
1236
0.68
---
---
---
---
---
---
---
---
---
---
1.8
1096
0.65
---
---
---
---
---
---
---
---
---
---
www.daikinac.com
SS-DSH3
Airflow Data — 4 Tons (cont.)
Standard Belt Drive — Horizontal ESP (" W.C.)
Turns Open 0
1
2
3
4
5
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
0.1
---
---
---
---
---
---
---
---
---
---
1726
0.37
0.2
---
---
---
---
---
---
---
---
1720
0.43
1575
0.36
0.3
---
---
---
---
1888
0.57
1744
0.48
1562
0.41
1398
0.34
0.4
---
---
---
---
1740
0.54
1579
0.45
1398
0.38
1217
0.31
0.5
---
---
1797
0.56
1586
0.51
1420
0.42
1216
0.36
1004
0.28
0.6
1849
0.62
1658
0.53
1429
0.48
1252
0.40
997
0.32
---
---
0.7
1731
0.59
1528
0.51
1266
0.45
1039
0.36
---
---
---
---
0.8
1572
0.55
1355
0.47
1068
0.41
---
---
---
---
---
---
0.9
1431
0.52
1171
0.43
---
---
---
---
---
---
---
---
1.0
1245
0.48
987
0.39
---
---
---
---
---
---
---
---
1.1
1059
0.44
---
---
---
---
---
---
---
---
---
---
High-Static Belt Drive — Horizontal ESP (" W.C.)
Turns Open 0
1
2
3
4
5
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
0.6
---
---
---
---
---
---
---
---
---
---
1776
0.57
0.7
---
---
---
---
---
---
---
---
---
---
1652
0.54
0.8
---
---
---
---
---
---
---
---
1713
0.61
1498
0.51
0.9
---
---
---
---
---
---
1787
0.67
1573
0.57
1345
0.47
1.0
---
---
---
---
---
---
1668
0.63
1407
0.53
1163
0.44
1.1
---
---
---
---
1745
0.71
1513
0.59
1243
0.49
960
0.40
1.2
---
---
---
---
1612
0.68
1339
0.54
1059
0.46
---
---
1.3
---
---
1724
0.78
1447
0.63
1161
0.50
---
---
---
---
1.4
1802
0.90
1551
0.72
1279
0.58
---
---
---
---
---
---
1.5
1667
0.85
1409
0.67
1108
0.54
---
---
---
---
---
---
1.6
1508
0.80
1221
0.62
---
---
---
---
---
---
---
---
1.7
1343
0.74
1005
0.56
---
---
---
---
---
---
---
---
1.8
1191
0.70
---
---
---
---
---
---
---
---
---
---
SS-DSH3
www.daikinac.com
17
Airflow Data — 5 Tons Standard Direct Drive Motor — Horizontal CFM
Static
Amps
Watts
RPM
Standard Direct Drive Motor — Down Shot Speed Tap
CFM
Static
Amps
Watts
RPM
1225
0.1
1.4
175
605
1205
0.1
1.47
180
635
1170
0.2
1.46
180
645
1150
0.2
1.54
185
675
1085
0.3
1.54
180
690
1065
0.3
1.59
185
730
1015
0.4
1.62
185
735
980
0.4
1.68
195
760
880
0.5
1.74
190
790
860
0.5
1.79
200
810
835
0.6
1.77
210
815
800
0.6
1.82
220
840
1425
0.1
1.80
230
670
1375
0.1
1.94
235
690
1330
0.2
1.96
240
705
1300
0.2
2.01
245
720
1260
0.3
2.00
250
735
1230
0.3
2.05
255
750
1210
0.4
2.10
260
770
1180
0.4
2.15
265
790
1135
0.5
2.16
265
810
1100
0.5
2.22
275
830
1040
0.6
2.28
280
860
1005
0.6
2.33
285
890
T1
T2
1000
0.7
2.38
290
885
970
0.7
2.43
295
900
940
0.8
2.46
300
925
915
0.8
2.51
310
940
870
0.9
2.52
310
955
845
0.9
2.57
315
980
1840
0.1
3.30
425
810
1790
0.1
3.37
573
948
1800
0.2
3.37
435
830
1745
0.2
3.40
580
965
1740
0.3
3.45
450
865
1700
0.3
3.49
595
985
1690
0.4
3.52
465
890
1650
0.4
3.56
606
1007
1635
0.5
3.58
475
920
1580
0.5
3.63
616
1035
1535
0.6
3.64
490
945
1515
0.6
3.71
626
1059
1505
0.7
3.70
500
970
1480
0.7
3.75
648
1079
150
0.8
3.80
510
995
1420
0.8
3.84
648
1100
1405
0.9
3.81
530
1035
1375
0.9
3.85
652
1117
2005
0.1
4.30
575
880
1920
0.1
4.48
650
976
1965
0.2
4.41
590
900
1910
0.2
4.57
620
940
1895
0.3
4.52
610
930
1850
0.3
4.66
635
965
1835
0.4
4.63
620
955
1795
0.4
4.78
655
990
1790
0.5
4.75
635
980
1760
0.5
4.84
670
1020
1745
0.6
4.84
650
1005
1710
0.6
4.96
685
1045
1695
0.7
4.91
660
1030
1640
0.7
5.06
675
1065
1650
0.8
5.03
675
1055
1610
0.8
5.19
690
1090
1600
0.9
5.10
675
1080
1560
0.9
5.22
700
1125
2120
0.1
5.10
690
930
2090
0.1
5.35
720
970
2075
0.2
5.15
710
950
2040
0.2
5.38
740
990
2025
0.3
5.23
720
975
1985
0.3
5.70
755
1025
1975
0.4
5.35
735
995
1930
0.5
5.46
750
1020
1875
0.6
5.59
770
1835
0.7
5.64
1795
0.8
5.73
1735
0.9
5.82
T3
T4
1935
0.4
5.44
760
1035
1900
0.5
5.82
780
1050
1040
1855
0.6
5.73
800
1075
780
1065
1810
0.7
5.69
810
1090
790
1090
1750
0.8
5.82
825
1120
805
1110
1680
0.9
6.13
790
1128
T5
Speed Tap
T1
T2
T3
T4
T5
Notes • Assumes dry coil with filter in place; SCFM correction for wet coil = 4% • Five-ton models are shipped from the factory with speed tap set on T4.
18
www.daikinac.com
SS-DSH3
Airflow Data — 5 Tons (cont.)
Standard Belt Drive — Down Shot ESP (" W.C.)
Turns Open 0
1
2 CFM
3
5
BHP
CFM
BHP
CFM
BHP
2115
0.56
1961
0.50
1816
0.41
0.67
2002
0.53
1855
0.47
1703
0.39
2047
0.63
1885
0.52
1751
0.44
1597
0.36
0.71
1941
0.59
1790
0.50
1633
0.42
1466
0.33
2030
0.68
1834
0.55
1681
0.45
1514
0.39
1314
0.30
0.69
1909
0.65
1716
0.51
1550
0.43
1367
0.37
---
---
1951
0.72
1788
0.62
1595
0.47
1425
0.39
1212
0.35
---
---
0.8
1840
0.70
1687
0.59
1465
0.43
1278
0.36
---
---
---
---
0.9
1728
0.65
1558
0.54
1330
0.39
---
---
---
---
---
---
1.0
1622
0.63
1432
0.50
1192
0.37
---
---
---
---
---
---
1.1
1491
0.60
1288
0.46
---
---
---
---
---
---
---
---
1.2
1325
0.57
---
---
---
---
---
---
---
---
---
---
CFM
BHP
CFM
BHP
2021
0.87
1854
0.72
BHP
CFM
BHP
0.1
---
---
---
---
0.2
---
---
---
---
2153
0.3
---
---
---
---
0.4
---
---
2142
0.5
2170
0.67
0.6
2062
0.7
BHP
4
CFM
CFM
High-Static Belt Drive — Down Shot ESP (" W.C.)
Turns Open 0
1
2
3 CFM
4 BHP
5
CFM
BHP
CFM
BHP
CFM
BHP
0.6
---
---
---
---
---
---
0.7
---
---
---
---
---
---
2138
0.91
1928
0.83
1760
0.69
0.8
---
---
---
---
---
---
2017
0.87
1813
0.80
1623
0.66
0.9
---
---
---
---
2110
0.97
1897
0.83
1690
0.78
1486
0.62
1.0
---
---
2145
1.07
1994
0.93
1786
0.79
1569
0.72
1361
0.59
1.1
---
---
2047
1.03
1886
0.90
1684
0.76
1446
0.67
1233
0.55
1.2
2156
1.16
1949
1.00
1778
0.86
1552
0.71
1305
0.63
---
---
1.3
2050
1.12
1851
0.97
1661
0.81
1441
0.68
---
---
---
---
1.4
1944
1.09
1748
0.93
1534
0.77
1298
0.64
---
---
---
---
1.5
1845
1.06
1627
0.88
1413
0.72
---
---
---
---
---
---
1.6
1742
1.01
1527
0.83
1299
0.68
---
---
---
---
---
---
1.7
1649
0.97
1400
0.79
---
---
---
---
---
---
---
---
1.8
1526
0.93
1274
0.75
---
---
---
---
---
---
---
---
SS-DSH3
www.daikinac.com
19
Airflow Data — 5 Tons (cont.)
Standard Belt Drive — Horizontal ESP (" W.C.)
Turns Open 0
1
2
3 CFM
4 BHP
CFM
BHP
2203
0.57
2041
0.47
0.61
2084
0.54
1914
0.45
2118
0.60
1967
0.51
1794
0.42
0.68
2011
0.58
1835
0.49
1647
0.39
2061
0.64
1889
0.53
1701
0.45
1477
0.36
0.73
1928
0.62
1742
0.51
1536
0.43
1308
0.34
2009
0.70
1792
0.58
1601
0.47
1362
0.40
---
---
0.80
1895
0.67
1646
0.54
1436
0.44
1188
0.36
---
---
1941
0.75
1750
0.62
1495
0.50
1271
0.40
---
---
---
---
1.0
1823
0.73
1609
0.58
1339
0.48
---
---
---
---
---
---
1.1
1675
0.69
1448
0.54
1183
0.45
---
---
---
---
---
---
1.2
1487
0.65
1268
0.50
---
---
---
---
---
---
---
---
BHP
CFM
BHP
CFM
BHP
0.1
---
---
---
---
---
---
0.2
---
---
---
---
---
---
2248
0.3
---
---
---
---
---
---
0.4
---
---
---
---
2180
0.5
---
---
---
---
0.6
---
---
2145
0.7
2192
0.83
0.8
2067
0.9
BHP
5
CFM
CFM
High-Static Belt Drive — Horizontal ESP (" W.C.)
Turns Open 0
1
2
3
4
5
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
CFM
BHP
0.6
---
---
---
---
---
---
---
---
2246
0.97
2060
0.80
0.7
---
---
---
---
---
---
---
---
2142
0.93
1956
0.77
0.8
---
---
---
---
---
---
2241
0.97
2014
0.89
1803
0.74
0.9
---
---
---
---
---
---
2108
0.92
1878
0.86
1651
0.69
1.0
---
---
---
---
---
---
1984
0.88
1743
0.80
1512
0.65
1.1
---
---
---
---
2096
1.00
1871
0.84
1607
0.74
1370
0.62
1.2
---
---
2166
1.11
1976
0.96
1724
0.79
1450
0.69
1201
0.57
1.3
---
---
2057
1.07
1845
0.90
1601
0.75
1301
0.65
---
---
1.4
2160
1.21
1942
1.03
1705
0.85
1443
0.71
---
---
---
---
1.5
2050
1.18
1808
0.98
1570
0.80
1285
0.66
---
---
---
---
1.6
1935
1.13
1697
0.92
1443
0.76
---
---
---
---
---
---
1.7
1832
1.08
1556
0.88
1273
0.70
---
---
---
---
---
---
1.8
1696
1.03
1415
0.83
---
---
---
---
---
---
---
---
Air Flow Pressure Drop of Down Flow Economizer Airflow Pressure Drop of Downflow Economizer for 3 to 6 Ton Rofftop Units (100% Return Air) SCF,
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
in WG
0.02
0.04
0.05
0.07
0.09
0.12
0.14
0.17
0.21
0.24
0.28
20
www.daikinac.com
SS-DSH3
Crankcase Heater, High Efficiency MERV 13 Air Filter Option
High Efficiency MERV 13 Air Filter Option Flanders Pre Pleat M13 Air Velocity vs Resistance (Test Size: 24" x 24" x 2" High Capacity) 0.50 0.45 2" Deep
Resistance (in. w.g.)
0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00
0
100
200
300
400
500
600
700
Air Velocity (FPM)
Tonnage:
Filter Nominal Size:
Part Number:
Order QTY:
3
24 x 24 x 2
0160L00203
1
4
14 x 20 x 2
0160L00204
4
5, 6, 7.5
16 x 20 x 2
0160L00205
4
7.5(HP), 8.5, 10
16 X 24 X 2
0160L00206
4
12.5
20 x 25 x 2
0160L00202
4
15, 20
20 x 25 x 2
0160L00202
6
25
20 X 20 X 2
0160L00201
8
Crankcase Heater Selection Table ZP/ZPS…
Compressor Diameter
16-31
5.5"
39-83 103-137
6.58/7.3" 9.14” DC*,DT* & DS* Tonnage
Compressor Voltage 230V 460V 575V 0163R00002S 0163R00031S 0163R00032S 0130L00017S 0130L00020S 230V
0130L00018S 0130L00021S
0130L00019S 0130L00022S
Compressor Voltage 460V
Crankcase Heater Watts 40 70 90
575V
Crankcase Heater Watts
3 Ton
0163R00002S
0163R00031S
0163R00032S
40
4 Ton-12.5 Ton
0130L00017S
0130L00018S
0130L00019S
70
15-20 Ton**
0130L00017S
0130L00018S
0130L00019S
70
25 Ton
0130L00020S
0130L00021S
0130L00022S
90
*Includes C,G&H models. **If Compressor Diameter is 9.14” then use 25 Ton Crankcase heaters.
SS-DSH3
www.daikinac.com
21
Expanded Heating Data DSH036* MBh T/R kW COP EER HI PR LO PR
65 46.3 36 3.25 4.17 14.2 421 143
60 43.8 34 3.18 4.04 13.8 403 133
55 41.2 32 3.11 3.89 13.3 388 124
50 38.6 30 3.04 3.72 12.7 371 114
47 36.8 28 2.97 3.63 12.4 362 108
45 35.7 28 2.90 3.61 12.3 355 104
40 33.1 26 2.83 3.44 11.7 342 95
Outdoor Ambient Temperature 35 30 25 20 30.6 24.8 22.9 21.1 24 19 18 16 2.76 2.69 2.62 2.55 3.25 2.71 2.57 2.43 11.1 9.2 8.8 8.3 328 314 300 288 85 77 68 60
17 19.9 15 2.48 2.36 8.0 281 56
15 19.2 15 2.41 2.34 8.0 276 54
10 17.2 13 2.34 2.16 7.4 265 46
5 15.3 12 2.27 1.97 6.7 255 39
0 13.3 10 2.20 1.78 6.1 245 33
-5 11.4 9 2.12 1.57 5.3 236 29
-10 9.3 7 2.05 1.33 4.5 228 23
65 57.6 33 3.96 4.26 14.5 412 137
60 54.5 32 3.88 4.12 14.1 395 127
55 51.3 30 3.80 3.96 13.5 380 119
50 48.0 28 3.72 3.78 12.9 363 110
47 45.8 27 3.64 3.68 12.6 355 104
45 44.4 26 3.56 3.65 12.5 348 100
40 41.2 24 3.48 3.47 11.8 335 92
Outdoor Ambient Temperature 35 30 25 20 38.0 31.4 29.0 26.7 22 18 17 15 3.40 3.32 3.24 3.16 3.28 2.77 2.62 2.48 11.2 9.5 9.0 8.5 321 308 294 282 82 74 66 58
17 25.2 15 3.08 2.40 8.2 275 54
15 24.3 14 3.00 2.37 8.1 270 52
10 21.8 13 2.92 2.19 7.5 260 44
5 19.3 11 2.84 1.99 6.8 250 38
0 16.9 10 2.76 1.79 6.1 240 32
-5 14.4 8 2.68 1.57 5.4 231 28
-10 11.8 7 2.60 1.33 4.5 223 22
65 72.3 33 4.74 4.47 15.3 384 131
60 68.4 32 4.66 4.30 14.7 368 122
55 64.4 30 4.59 4.11 14.0 354 114
50 60.2 28 4.52 3.90 13.3 339 105
47 57.5 27 4.45 3.78 12.9 331 99
45 55.7 26 4.38 3.73 12.7 324 95
40 51.7 24 4.31 3.52 12.0 312 88
17 33.4 15 3.95 2.48 8.5 257 51
15 32.2 15 3.88 2.43 8.3 252 49
10 28.9 13 3.81 2.22 7.6 242 42
5 25.6 12 3.74 2.01 6.9 233 36
0 22.3 10 3.66 1.79 6.1 224 30
-5 19.1 9 3.59 1.55 5.3 216 27
-10 15.6 7 3.52 1.30 4.4 208 21
DSH048* MBh T/R kW COP EER HI PR LO PR DSH060* Outdoor Ambient Temperature MBh T/R kW COP EER HI PR LO PR
35 47.7 22 4.24 3.30 11.3 299 78
30 41.7 19 4.16 2.93 10.0 287 70
Above information is for 70º indoor dry bulb; instantaneous capacity listed. High pressure measured at liquid line access fitting. Low pressure measured at compressor suction access fitting.
22
www.daikinac.com
25 38.4 18 4.09 2.75 9.4 274 63
20 35.4 16 4.02 2.58 8.8 263 55
kW = Total system power Amps: Unit Amps (comp+evap motor+condenser fan motor)
SS-DSH3
Heat Kit Electrical Data — 3 Tons
Model and Heat Kit Usage
MCA¹ @ 208 / 240V
MOP² (amps) @ 208 / 240V
DSH036***1D***
25
40
---
---
EHK1-10
77
80
10
1250-1350 CFM
EHK1-15
103
110
15
1400-1440 CFM
DSH036***3D***
Actual kW & BTU @ 240V
Recommended Airflow Range
17
25
---
---
EHK3-10
41 / 47
45 / 50
10
1250-1350 CFM
EHK3-15
54 / 62
60 / 70
15
1400-1440 CFM
18
25
---
---
EHK3-10
42 / 48
45 / 50
10
1250-1350 CFM
EHK3-15
55 / 63
60 / 70
15
1400-1440 CFM
MCA¹ @ 480V
MOP² (amps) @ 480V
Actual kW & BTU @ 480V
Recommended Airflow Range
DSH036***4B***
10
15
---
---
EHK4-10
25
25
10
1250-1350 CFM
EHK4-15
33
35
15
1400-1440 CFM
MCA¹ @ 575V
MOP² (amps) @ 575V
Actual kW & BTU @ 575V
Recommended Airflow Range
DSH036***7B***
8
15
---
---
EHK7-10
20
25
10
1400-1475 CFM
EHK7-15
26
30
15
1575-1650 CFM
DSH036***3B***
Model and Heat Kit Usage
Model and Heat Kit Usage
¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection device
kW Correction Factors kW Correction Factor for 1- & 3-Phase Units Supply Voltage Correction Factor
240
230
220
210
208
1
0.93
0.82
0.78
0.76
kW Correction Factor for 480V Units Actual Voltage
460
440
430
Correction Factor
0.92
0.84
0.8
For other voltage use voltage² / 480²
kW Correction Factor for 575V Units Supply Voltage
560
550
540
Correction Factor
0.95
0.91
0.88
Multiply rated kW by correction factor to get actual kW
SS-DSH3
www.daikinac.com
23
Heat Kit Electrical Data — 4 Tons
Model and Heat Kit Usage
MCA¹ @ 208 / 240V
MOP² (amps) @ 208 / 240V
Actual kW & BTU @ 240V
Recommended Airflow Range
DSH048***1D***
29
45
---
---
EHK1-10
81
90
10
1400-1800 CFM
EHK1-15
107
110
15
1575-1800 CFM
EHK1-18
123
125
18
1575-1800 CFM
DSH048***3D***
21
30
---
---
EHK3-10
44 / 51
45 / 60
10
1400-1800 CFM
EHK3-15
57 / 66
60 / 70
15
1575-1800 CFM
EHK3-18
65 / 75
70 / 80
18
1575-1800 CFM
22
30
---
---
EHK3-10
45 / 52
45 / 60
10
1400-1800 CFM
EHK3-15
58 / 67
60 / 70
15
1575-1800 CFM
EHK3-18
66 / 76
70 / 80
18
1575-1800 CFM
MCA¹ @ 480V
MOP² (amps) @ 480V
Actual kW & BTU @ 480V
Recommended Airflow Range
DSH048***4B***
10
15
---
---
EHK4-10
25
30
10
1400-1800 CFM
EHK4-15
33
35
15
1575-1800 CFM
EHK4-18
37
40
18
1575-1800 CFM
MCA¹ @ 575V
MOP² (amps) @ 575V
Actual kW & BTU @ 575V
Recommended Airflow Range
DSH048***7B***
8
15
---
---
EHK7-10
21
25
10
1400-1800 CFM
EHK7-15
27
30
15
1575-1800 CFM
EHK7-18
31
35
18
1575-1800 CFM
DSH048***3B***
Model and Heat Kit Usage
Model and Heat Kit Usage
¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection device
kW Correction Factors kW Correction Factor for 1- & 3-Phase Units Supply Voltage Correction Factor
240
230
220
210
208
1
0.93
0.82
0.78
0.76
kW Correction Factor for 480V Units Actual Voltage
460
440
430
Correction Factor
0.92
0.84
0.8
For other voltage use voltage² / 480²
kW Correction Factor for 575V Units Supply Voltage
560
550
540
Correction Factor
0.95
0.91
0.88
Multiply rated kW by correction factor to get actual kW
24
www.daikinac.com
SS-DSH3
Heat Kit Electrical Data — 5 Tons
Model and
Heat Kit Usage
MCA¹ @ 208 / 240V
MOP² (amps) @ 208 / 240V
Actual kW & BTU @ 240V
Recommended Airflow Range
40 92 118 144 29 51 / 59 64 / 74 77 / 89 25 48 / 55 61 / 70 74 / 85
60 100 125 150 45 60 / 60 70 / 80 80 / 90 40 50 / 60 70 / 80 80 / 90
--10 15 20 --10 15 20 --10 15 20
--1750-2250 CFM 1750-2250 CFM 1850-2250 CFM --1750-2250 CFM 1750-2250 CFM 1850-2250 CFM --1750-2250 CFM 1750-2250 CFM 1850-2250 CFM
MCA¹ @ 480V
MOP² (amps) @ 480V
Actual kW & BTU @ 480V
Recommended Airflow Range
12 27 35 43
20 30 40 45
--10 15 20
--1750-2250 CFM 1750-2250 CFM 1850-2250 CFM
MCA¹ @ 575V
MOP² (amps) @ 575V
Actual kW & BTU @ 575V
Recommended Airflow Range
10 23 29 35
15 25 30 40
--10 15 20
--1750-2250 CFM 1750-2250 CFM 1850-2250 CFM
DSH060***1D*** EHK1-10 EHK1-15 EHK1-20 DSH060***3D*** EHK3-10 EHK3-15 EHK3-20 DSH060***3B*** EHK3-10 EHK3-15 EHK3-20 Model and Heat Kit Usage DSH60***4B*** EHK4-10 EHK4-15 EHK4-20 Model and Heat Kit Usage DSH060***7B*** EHK7-10 EHK7-15 EHK7-20
¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection Device
kW Correction Factors kW Correction Factor for 1- & 3-Phase Units Supply Voltage Correction Factor
240
230
220
210
208
1
0.93
0.82
0.78
0.76
kW Correction Factor for 480V Units Actual Voltage
460
440
430
Correction Factor
0.92
0.84
0.8
For other voltage use voltage² / 480²
kW Correction Factor for 575V Units Supply Voltage
560
550
540
Correction Factor
0.95
0.91
0.88
Multiply rated kW by correction factor to get actual kW
SS-DSH3
www.daikinac.com
25
26
www.daikinac.com 33.805
FRONT VIEW
73.945
FLUE/VENT OUTLET
GAS LINE ENTRANCE
COMBUSTION AIR INLET (GAS UNITS)
ALL DIMENSIONS GIVEN ARE IN INCHES ALL DIMENSIONS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
11.265
TOP VIEW
10.060
6.196
3 THRU 5 TON COMMERCIAL
DSH036-060
4.475
12.000
SUPPLY AIR DUCT
CONDENSATE DRAIN OUTLET
17.000
RIGHT END VIEW
48.196
LIFTING SHACKLE HOLES BOTH SIDES AND ENDS
7.165
31.540
20.853
FORK HOLES BOTH SIDES AND BOTH ENDS
11.000 RETURN AIR DUCT
Dimensions
SS-DSH3
Dimensions (cont.)
CONDENSATE DRAIN BOTTOM EXIT
19.470 5.104
MOD 3 TON GAS, HT PUM 4 TON GAS, HT PUM 5 TON GAS, HT PUM 6 TON GAS, HT PUM
12.000
SUPPLY AIR DUCT
17.000
48.312
23.442 20.905
11.000
6.192
5.558
25.000 RETURN AIR DUCT 74.061
BASE PAN VIEW (VIEWED FROM TOP)
CONDENSATE DRAIN BOTTOM EXIT
MODEL TONNAGES 3 TON COMMERCIAL GAS, HT PUMP, AIR CONDITIONER 4 TON COMMERCIAL GAS, HT PUMP, AIR CONDITIONER 5 TON COMMERCIAL GAS, AIR CONDITIONER 5 TON COMMERCIAL HT PUMP
"A"
"B"
"C"
38.840
16.555
26.055
38.840
16.555
26.055
38.840
16.555
26.055
42.840
20.555
30.055
7.984
LINE WIRE ENTRANCE "A" "C" "B" 8.555
TSTAT WIRE ENTRANCE
5.872 10.372
LEFT END VIEW
TURN AIR DUCT 74.061
BASE PAN VIEW EWED FROM TOP)
SS-DSH3
www.daikinac.com
27
Unit Clearances Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 48” on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit’s fresh-air intake.
Electrical Entrance Locations High-Voltage Entrance (Remove Plug)
12⅜” 3½” Dia. 30¼” Power Thru the Curb
47½”
Low-Voltage Entrance
7½”
Corner & Center-of-Gravity Locations 3-Ton Weights
4-Ton Weights
5-Ton Weights
Corner Weight (A)
131
133
145
Corner Weight (B)
182
184
205
Corner Weight (C)
112
113
125
Corner Weight (D)
155
156
175
Unit Shipping Weight
605
610
675
Unit Operating Weight
580
585
650
Unit Weights Return
30”
Condenser Coil
Evaporator Coil
Supply
Note: Weights are calculated without accessories installed. Compressor
37”
28
www.daikinac.com
SS-DSH3
Roof Curb Installation — Rigging Provisions for forks have been included in the unit base frame. No other fork locations are approved. • Unit must be lifted by the four lifting holes located at the base frame corners. • Lifting cables should be attached to the unit with shackles. • The distance between the crane hook and the top of the unit must not be less than 60”. • Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual. Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct. To assist in determining rigging requirements, unit weights are shown below. Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. • Determine sufficient structural support before locating and mounting the curb and package unit. • Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory. • Contractor furnishes curb insulation, cant strips, flashing, and general roofing material. • Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate supply and return duct openings. Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended. See the manual shipped with the roof curb for assembly and installation instructions. Top View
3-D View 1.625 TYP.
Insulated Panels
70¾
70.75 O.D. 3
3
14
40¼
S/A
14 x 20 Supply Opening
14.625 20
20
37 40.25 I.D. O.D.
16.000 3
14
31⅝ x 14 Return Opening
O 1.750 14
¾
15/6
32.875
31.625
R/A
15.250
14 1⅜
SS-DSH3
www.daikinac.com
67.5 I.D.
29
Wiring Diagram — DSH036*/DSH048* SINGLE PHASE 208-230V/1/60HZ DIRECT DRIVE
RD
PU BK
1
C
C
C
R
R
C
BK BK
PU
PLF 2 RD PU
OR PU
0-RV
BR
RD
WH
Y
C
H
F
RCCF
BK
R-PS1
DFT
R-DFT
DF2
DF1
Y PS2
RD
BK RD
3
6
9
2
5
8
1
4
7
PLF 1
YL
RD
GR
PU
WH OR BL
BR
RD BR
BL YL
RD RD
BL PU
PU
BK
EM
BR
DFT
3 SPEED
BL
BK
BK
BC
RVC
EM
BR
3 SPEED
RD
PU BR BK
BC
PU
L1
C
T1
C
CH
COMP
S C
2 POLE ONLY SEE NOTE 8
H
DF2
DF1
HVDR
RCCF
F
EM
BR
208-240V SEE NOTE 3
3
1
DFT
RVC
DFT C-RV DC W Y
O-RV
R
R
O
BR
DFT
R-DFT
PS2
R-PS1
C CNT
LPS
R
7
4
8
5
9
6
C
HPS
TABLE 1
TABLE 2
SPEED TAPS ALTERNATE MOTOR WIRING RD LOW COLOR TERMINATION BL RD MED COM (EBTDR) BK HIGH BK M1 (EBTDR) BL M2 (EBTDR) PU PIN 1 (24V XFMR) SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION JUNCTION TERMINAL
PLF
INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION
9 8 7 6 5 4 3 2 1
EBTDR
PLF2
R S1
S2
O
R
W2 W1
Y2
Y1
THERMOSTAT
++
G R XFMR C
BLOWER INTERLOCK RELAY CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER BLOWER CAPACITOR
USE N.E.C. CLASS 2 WIRE 5. ECONOMIZER PLUG LOCATED IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH TO ECONOMIZER ACCESSORY. 6. DIAGRAM SHOWS FACTORY SPEED TAP SETTINGS. 7. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 8. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION. 9. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR CONNECTED TO ANY OTHER COMMON (24V).
TR 24V
G
SMOKE/FIRE DETECTOR REPLACES JUMPER
BL/PK
++
2
C
T H E R M O S T A T
Y1 Y2 R G W1 W2 O C S2 S1
BL/PK
TB1 TR BC NOTES: 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE M1 OR M2 WIRE TO COM TERMINAL ON EBTDR AND PLACE WIRE REMOVED FROM COM ON EMPTY M1 OR M2 TERMINAL. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. USE COPPER CONDUCTORS ONLY.
CM
EBTDR
BK
HPS
COMPONENT LEGEND BIR C CCR CH CHS CM COMP DC DFT ECON EM GND HPS HVDR LPS LVDR LVJB PLF RVC RCCF
C
T2
R
SEE NOTE 7
PU
PU
COMP
L2
2 POLE ONLY SEE NOTE 8
BK
GR
TB1
CM
SUPPLY VOLTAGE 208-240/1/60 CHS
CH
T3 T2 T1
ALTERNATE MOTOR 6-WIRES SEE TABLE 1
RD
YL
RD
YL PU RD GR WH BR OR BL BL BR PK
RD
RD CHS
BK
YL
RD
CONTROL BOX
BK RD
YL
3 6 9 2 5 8 1 4 7
LVJB
WH
W
PU
GND OR RD GR
BR
PU
C-RV
RD
BK
BK
BK
BIR
0
HVDR
SEE NOTE 2
L1
T1
PU
3
DC
0
LVDR
L2
T2
2
CNT
YL
RD RD
BR
BR
CCR
PK
BL
YL/PK
YL
2 0 8 2 4 0 / 1 / 6 0
SWITCH (PRESS.) OVERCURRENT PROT. DEVICE
EQUIPMENT GROUND
FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP
THERMOSTAT FIELD WIRING
NO ECONOMIZER W
W G
WH GR
R
RD
R
Y1
YL
Y
G
Y2 C
BL
O
OR
C O STAT
TB1
WITH ECONOMIZER OPTION W G
WH GR
R
RD
Y1
YL
W G R Y
Y2 C
BL
O
OR
TB1
C O STAT
2 STAGE COOLING W G
WH GR
W
FIELD SPLICE
R
RD
Y1
YL
R Y1
SWITCH (TEMP)
Y2
PK
Y2
FIELD GROUND
IGNITER
G
C
BL
C
O
OR
O STAT
TB1
⚡
LPS
SEE NOTE 7
RD
BL
BL
COM K1 SEE NOTE #2 NC SPEED M1 M2 UP BL BK BK
YL/PK
24V
RD
NO
K1
BK
BL
BL
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
R XFMR-R XFMR-C C
BL
TR
⚠ Warning
GR
EBTDR
SEE NOTE 8
SEE NOTE 9
3
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
BL
2
208 240
C
++
G
1
BR
RD
++
BK
SEE NOTE 5 208-240/1/60 0140L02904-B
30
www.daikinac.com
SS-DSH3
Wiring Diagram — DSH060* SINGLE PHASE 208-230V/1/60HZ DIRECT DRIVE
SEE NOTE 7
BK
BL
BK
RD RD
T2
L2
L2
YL/PK
PK
BL
C BK BK
BL
PU
YL
C
C
R
R
C
CNT
OR
0 0
WH
BR
BK
0-RV
WH
W Y
HVDR
PU
Y
YL R-PS1
DFT
R-DFT
D2
C
H
BK
PS2
RCCF
YL
WH
RD
C-RV
F
RD
3
6
9
2
5
8
1
4
7
WH
WH
BR
RD BR
BL RD PU
WH PU
RD
SEE NOTE 2
RD
1 2 3 4 5
EM C L G N
DFT
BL
PU
BK
BL
LVJB
YL PU RD GR GR
PLF 1
1 5 OR BR YL
BR
BK
YL
BK
RD
TB1
YL
PU
BL/PK
CM
CONTROL BOX
BK
REPLACE JUMPER WITH SMOKE/FIRE DETECTOR
BL/PK
CH
HPS
GR
RVC
L1
COMPONENT LEGEND
L2
C CCR CH CHS CM COMP DC DFT ECON EM GND HPS HVDR LPS LVDR LVJB PLF RVC RCCF
SUPPLY VOLTAGE 208-240/1/60
C
T1
C
T2
R C
COMP
S SEE NOTE 7
H
C
DF1
DF2
HVDR
RCCF
F
CM
TB1 TR
SEE NOTE 6
CHS
N
EM
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM "3" AND "4" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. USE COPPER CONDUCTORS ONLY
L
G
208-240V SEE NOTE 3
2
3
++
TR
DFT
24V
RVC
R
C-RV
O-RV
R
O
W
USE N.E.C. CLASS 2 WIRE 5. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY. 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.
1
R-DFT DC R-PS1
Y
DFT PS2
C CNT
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION JUNCTION
1 2 3 4 5
LPS P 4 L F 5 1 6
SEE NOTE 2
EQUIPMENT GROUND
TERMINAL
C
HPS
FIELD GROUND
PLUG CONNECTION
FIELD SPLICE SWITCH (TEMP)
SWITCH (PRESS.)
IGNITER
OVERCURRENT PROT. DEVICE
9 8 7 6 5 4 3 2 1 PLF2
S2
O
R
W2 W1
Y2
THERMOSTAT
Y1
G
C
FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK RD RED PU PURPLE YL YELLOW WH WHITE BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP
THERMOSTAT FIELD WIRING
NO ECONOMIZER W
W
G
WH GR
R
RD
R
Y1
YL
Y
G
Y2 C
BL
O
OR
C O STAT
TB1
WITH ECONOMIZER OPTION W G
WH GR
R
RD
Y1
YL
W G R Y
SEE NOTE 5
C
BL
O
OR
TB1
C O STAT
2 STAGE COOLING W
WH GR
W
G R
RD
Y1
YL
R Y1
Y2
PK
Y2
C
BL
C
O
OR
O STAT
TB1
G
++
S1
LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE
Y2
INTERNAL TO INTEGRATED CONTROL
EM C
SEE NOTE 6 FACTORY WIRING
CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR EQUIPMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR COMPRESSOR AND FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER
NOTES:
CH
T H BK E R M O S T A T
BK
COMP
RD
Y1 Y2 R G W1 W2 O C S2 S1
WH
BR OR OR BL BL BL RD PK
T2 T1 T3
BK
GR
BK
GND OR RD GR PLF 2 3 6 9 PU 2 5 8 YL 1 4 7
DC
LVDR
DF1
BK
PU
CCR
TB1
SEE NOTE 4
YL
PU
BL
GR WH
L1
T1
PU
BR
YL
RD 2 0 8 L1 2 4 0 / NOTE 6 1 RD / 6 0 CHS NOTE 5 RD
BK
24V
⚡
3 240
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
2 208 TR
⚠ Warning
1 C
RD
RD
BL
BL
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
YL/PK LPS
++
RD
++
WH
208-240/1/60 0140L05410-A
SS-DSH3
www.daikinac.com
31
Wiring Diagram — DSH036*/ DSH048*/ DSH060* THREE PHASE 208-230V / 3 / 60HZ BELT DRIVE
WIRING DIAGRAMS
DSH036*/DSH048*/DSH060* (B) THREE PHASE 208-230V/3/60HZ BELT DRIVE
T3
RD RD
T2
BK BK
L3
L2
L2
C
T1
L1
C
C
C
R
R
DC
CCR
BL
PU
CNT
OR
0
YL GR
0
LVD R
RD
0-RV
W
L2
R-PS1
DFT
DF2
DF1
R-DFT
Y
RD L1
BK RCCF BK
Y
HVDR
RD OR
YL
WH
C-RV
BK
BR
PS2
PU
C
F
RD
L3 C
WH
PU 3
6
9
2
5
8
1
4
7
PLF1 RD
T3
T1
T2
BK
RD OR
YL PU RD GR WH BR OR BL
RD GR WH OR BL BL RD BR BR PK
BR
BL
PU
BC
RD
BK
CH
BK
RD RD
GR EM
RD DFT
CHS
PU
BK
BR
BK
YL
RD
BK
PU
BL/PK
CM COMP
SEE NO TE 5
OR
Y1 Y2 R G W1 W2 O C S2 S1
TB1
YL
T H E R M O S T A T
REPLACE JUMPER WITH SMOKE/FIRE DETECTOR
BL/PK
T3 T1 T2
BK
RD
PLF2 3 6 9 PU 2 5 8 1 4 7 YL BL
HPS
RVC COMPONENT LEGEND
SUPPLY VOLTAGE 208-240/3/60
L1
CH
CHS T1
C
T2
T2
C
L3
L2
SEE NO TE 5
BC C CCR CH CHS CM COMP DC DFT ECON EBTDE MR EM GND HPS HVDR LPS LVDR PLF RVC RCCF
COMP
C
T3
T3 C
DF2
DF1
HVDR
R CC F
F
CM
TB1 TR
BLOWER CONTACTOR COMPRESSOR CONTACTOR RELAY CONTACTOR CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY EVAPORATOR MOTOR EQUIPMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER
NOTES:
T1 BC
EM T3
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY
BC
T2
2
3 EBTDR
R
RVC
++
208-240V
BC
1
24V R
G
O-RV
C-RV
USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. 4. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 5. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED.
SEE NOTE 4
TR C
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION
DFT R O
W
DFT
R-DFT
DC Y R-PS1
PS2
LPS
P 4 L F 5 1 6
9 8 7 6 5 4 3 2 1 S2
O
R
W2 W1
Y2
THERMOSTAT
Y1
G
FIELD GROUND FIELD SPLICE SWITCH (TEMP)
SWITCH (PRESS.)
C
HPS
++
S1
EBTDR
EBTDR
EQUIPMENT GROUND
TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION
BC
R
JUNCTION
C CNT
IGNITER
OVERCURRENT PROT. DEVICE
FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING
HIGH VOLTAGE LOW VOLTAGE WIRE CODE
BLACK BLUE BROWN GREEN ORANGE PINK PURPLE RED WHITE YELLOW BLUE WITH PINK STRIP YELLOW WITH PINK STRIP
BK BL BR GR OR PK PU RD WH YL BL/PK YL/PK
THERMOSTAT FIELDWIRING
++
HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
BL
GR
⚡
GND
BL
YL
L1
SEENOTE 2
PU
BR
YL/PK YL/PK
2 0 8 2 4 0 / 3 / 6 0
PB
L3
NO ECONOMIZER W G R Y1 Y2
WH GR RD YL
W G R Y1
WH GR RD YL
C O
BL OR
BL C C OR O O STAT TB1 WITH ECONOMIZER OPTION
Y2
TB1
2 STAGE COOLING
PLF2
W G R Y1
WH GR RD YL
C O
BL OR
Y2
C
SEE NOTE 3
208-240/3/60 0140L05412-A
W G R Y
TB1
PK
W G R Y C O STAT
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
PK
PU
NC M2
BL
BL
YL
BK
⚠ Warning
TR
24V
GR
COM
3
208 240
RD
NO
SPEED M1 UP
BL
2
1
C
RD
BK
BL
++
LPS
SEE NOTE 4 BL
BK
GR
G EBTDR R K1 XFMR-R XFMR-C K1 C
BL
OR RD
RD
BR
RD
RD
RD
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
BK
OR
W G R Y1
Y2
C O STAT
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 35
32
www.daikinac.com
SS-DSH3
Wiring Diagram — DSH036* / DSH048*DSH036* DSH060*(4B/7B)/DSH048* THREE PHASE 460/575V/3/60HZ BELT DRIVE (4B/7B)/DSH060* (4B/7B)
THREE PHASE 460/575V/3/60HZ BELT DRIVE
GR
R XFMR-R XFMR-C C BL
SPEED UP
BL
K1
NO
K1
COM
TR
RD
24V
PK
PU
NC M2
M1
BL
460 575
C
BR GR
BL
3
1
EBTDR
T3
RD RD
T2
C
C
C
R
R
CCR
YL/PK YL
OR
RD
BK
GR
RD OR
BK
1
RD
RD
5
8
1
4
7
9 BR
BL
YL RD
BL/PK BL/PK
BK
DFT
PU
BL
BR
YL
BK
T H E R M O S T A T
Y1 Y2 R G W1 W2 O C S2 S1
TB1
CHS
BL
RD
BK
SEE NOTE 4 T3 T1 T2
CM
HPS
CH
GR
6
CMR
PU
BK
3 2
PLF 1
2
RD
BK
EM
3
BK
BL
F
RD
BL
CHR
C
RCCF
PS2
R-PS1
DFT
R-DFT
DF2
DF1
BK
YL
YL PU RD RD GR GR WH WH BR OR OR BL BL RD BR BR PK
BK
RD
RD
T3
T2
WH
PU
PU
Y
L3
C T1
YL
WH
W
BR
BC
OR
PLF 2 3 6 9 3 2 5 8 PU 1 4 7
BR
Y
L2
RD
RD
C-RV
HVDR
L1
GR
RD
BK
0-RV
BL
GND
OR
0
LVDR
4 6 0 5 7 5 / 3 / 6 0
L1
SEE NOTE 2
0
YL BL
L2
BL
PU
CNT
L2 L1
T1
BR
DC
L3
PU
BR
LPS YL/PK
L3
C
BK BK
BL
BK RD
BL
YL
BL
RD
BK
RD
BK
⚡
BL
RD
COMP
RD
REPLACE JUMPER WITH SMOKE / FIRE DETECTOR
RVC
SEE NOTE 4
RD BL
COMPONENT LEGEND L2
SUPPLY VOLTAGE 460-575/3/60 C
T2
T2
T1
T1
C
COMP
C
T3
T3 C
L3
DF1
DF2
HVDR
RCCF
F
CM
SEE NOTE 4 CHR
3 T1 BC
CH
1 T2
BC T3
EM
3
24V
EBTDR R
R
BC 460V - 575V 1
G
TB1 TR NOTES:
TR C
CMR
RVC DF2 O-RV C-RV DF1 R DC O W R-PS1 Y
R
R
HVDR
R
CHS
DFT
R-DFT C
PS2
CNT
LPS
EBTDR
EBTDR CHR
P 4 L F 5 1 6
BC
HPS
SEE NOTE 4
BLOWER CONTACTOR CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CRANKCASE HEATER RELAY CONDENSER MOTOR CONDENSER MOTOR RELAY COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY EVAPORATOR MOTOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105�C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY DFT
R
BC C CCR CH CHS CHR CM CMR COMP DC DFT ECON EBTD EMR EM GND HPS HVDR LPS LVDR PLF RVC RCCF
C 9 8 7 PLF2 6 5 4 3 2 1
++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. 4. CRANKCASE HEATER, CRANKCASE HEATER RELAY, AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION SWITCH (PRESS.) OVERCURRENT PROT. DEVICE
EQUIPMENT GROUND FIELD GROUND FIELD SPLICE SWITCH (TEMP) IGNITER
FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP
THERMOSTAT FIELD WIRING
NO ECONOMIZER W
S2
O
R
W2 W1
Y2
Y1
G
C
WH GR
R
RD
R
Y1
YL
Y
G
Y2 C
BL
O
OR
C O STAT
TB1
WITH ECONOMIZER OPTION W G
WH GR
W
R
RD
R
Y1
YL
G Y
Y2 C
BL
O
OR
TB1
C O STAT
2 STAGE COOLING W G
WH GR
R
RD
R
Y1
YL
Y1
Y2
PK
Y2
W G
C
BL
C
O
OR
O STAT
SEE NOTE 3
460-575/3/60 0140L05409-A
THERMOSTAT ++
SS-DSH3
W
G
TB1
S1
++
L1
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
G
OR
OR
⚠ Warning
RD
RD
RD
BR
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
BK
++
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
RING DIAGRAMS
www.daikinac.com
33
Wiring Diagram — DSH036*/DSH048* THREE PHASE 208-230V/3/60HZ DIRECT DRIVE
PU
RD
BR
1
BK
C
C
C
YL R
T2
L2
CCR
CNT
BK
GND BK
BK
PU
BR
YL
PU
BK
0-RV
RD BR
BL
WH
W
FC
Y
R-PS1
DFT
R-DFT
C
BK
F
RD
3
6
9
2
5
8
1
4
7
GR
PU
WH OR BL
BR
PLF 1
RD BR
BL YL
PU
BK
RD
RD
RD
BL
BK
EM
DFT
3 SPEED
BL
BK
BK
BC
RVC
EM
BR
3 SPEED
RD
PU BR BK
BC
PU
PU
PU
BL/PK
YL Y1 Y2 R G W1 W2 O C S2 S1
TB1
SMOKE/FIRE DETECTOR REPLACES JUMPER BL/PK
BK
CM
CH
COMP
RD
HPS
BK GR
RD
SEE NOTE 7
CHS SEE NOTE 7
C
T1
T2 T1
COMP
C
T3
T3 C
DF2
DF1
HVDR
RCCF
F
CM
SEE NOTE 7
CH
CHS
EM
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE M1 OR M2 WIRE TO COM TERMINAL ON EBTDR AND PLACE WIRE REMOVED FROM COM ON EMPTY M1 OR M2 TERMINAL. 3. FOR 208V TRANSFORMER OPERATION MOVE BK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. USE COPPER CONDUCTORS ONLY
BR
EBTDR
208-240V SEE NOTE 3
2
3
++
1
USE N.E.C. CLASS 2 WIRE 5. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY. 6. DIAGRAM SHOWS FACTORY SPEED TAP SETTINGS. 7. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR CONNECTED TO ANY OTHER COMMON (24V).
TR 24V
RVC
R
C-RV DC W Y
O
BR
DFT
O-RV
R
DFT
R-DFT
PS2
R-PS1
R
4
8
5
9
6
C CNT
C
HPS
COLOR RD BK BL PU
TERMINATION COM (EBTDR) M1 (EBTDR) M2 (EBTDR) PIN 1 (24V XFMR)
SPEED TAPS
RD BL BK
PLF2
R S2
O
R
W2 W1
Y2
Y1
JUNCTION
G
C
SWITCH (PRESS.) OVERCURRENT PROT. DEVICE
EQUIPMENT GROUND FIELD GROUND
LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BL BR GR OR PK PU RD WH YL BL/PK YL/PK
THERMOSTAT FIELD WIRING
NO ECONOMIZER WH GR
R
RD
R
Y1
YL
Y
G
Y2 C
BL
O
OR
C O STAT
TB1
WITH ECONOMIZER OPTION W G
WH GR
R
RD
Y1
YL
W G R Y
Y2 C
BL
O
OR
TB1 2 STAGE COOLING W
IGNITER
W
W G
FIELD SPLICE
SEE NOTE 5
www.daikinac.com
BLACK BLUE BROWN GREEN ORANGE PINK PURPLE RED WHITE YELLOW BLUE WITH PINK STRIP YELLOW WITH PINK STRIP
SWITCH (TEMP)
208-240/3/60 0140L02905-B
34
FACTORY WIRING
C O STAT
WH GR
W
G R
RD
Y1
YL
R Y1
PK
Y2
Y2
THERMOSTAT
++
G XFMR
S1
LOW MED HIGH
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION
INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION
9 8 7 6 5 4 3 2 1
EBTDR
C
ALTERNATE MOTOR WIRING
TERMINAL
PLF
R
TABLE 2
TABLE 1
LPS 7
BLOWER INTERLOCK RELAY CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR FAN CAPACITOR EQUIPMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VALVE COIL TERMINAL BLOCK (24V SIGNAL) TRANSFORMER BLOWER CAPACITOR
BIR C CCR CH CHS CM COMP DC DFT ECON EM FC GND HPS HVDR LPS LVDR LVJB PLF RVC TB1 TR BC NOTES:
C
T2
BK
COMPONENT LEGEND
L3
L2
SUPPLY VOLTAGE 208-240/3/60
++
L1
T H E R M O S T A T
T3 T2 T1
ALTERNATE MOTOR 6-WIRES SEE TABLE 1
RD
RD
YL
BK
RD
CONTROL BOX
LVJB
YL PU RD GR WH BR OR BL BL BR PK
WH
Y
PS2
OR RD GR PLF 2 3 6 9 2 5 8 1 4 7
PU
RD
C-RV
HVDR
PU
OR
0
LVDR
BR
SEE NOTE 4
L1
T1
PU
PU
0
PU
C
BK BK
3
BIR
DC
YL
PU
RD
2
BR
DF1
L3
RD YL
BK
BL
DF2
RD
RD 2 0 8 2 4 0 / 3 / 6 0
⚡
NC M2
YL/PK
R
PK
BL
T3
BK RD
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
BL
COM
BL
BL
BL
⚠ Warning
BL
3
TR 24V
RD
NO
R K1 XFMR-R XFMR-C K1 C SEE NOTE #2 SPEED M1 UP
LPS
YL/PK
EBTDR
2
208 240
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
BL
C
GR
++
G
1
BR
RD
SEE NOTE 8
BK
BK
G
C
BL
C
O
OR
O STAT
TB1
SS-DSH3
Wiring Diagram — DSH060* THREE PHASE 208-230V/3/60HZ DIRECT DRIVE
RD
SEE NOTE 6
SEE NOTE 3
RD
YL
BL
RD RD
T2
L3
L2
L2
L1
T1
YL
GND
C
DC
C
C
R
R
RD
CCR
PU
CNT
PU
OR
0 0
LVDR
W
GR WH
BK
Y
HVDR
R-PS1
DFT
R-DFT
DF2
DF1
RD
5
3
6
9
2
5
8
1
4
PU
OR BR YL WH PU
PU
RD
PU BR BK
BK
BK
TB1
WH BR OR BL
T H E R M O S T A T
REPLACE JUMPER WITH BL/PK SMOKE/FIRE DETECTOR
YL BL/PK
CM COMP
RVC
L1
L2
COMPONENT LEGEND
L3
C CCR CH CHS CM COMP DC DFT ECON EM GND HPS HVDR LPS LVDR LVJB PLF RVC RCCF
SUPPLY VOLTAGE 208-240/1/60
T1
C
T2
T2 COMP
C
T3
T3 C
DF2
DF1
HVDR
RCCF
F
CM
SEE NOTE 6
TB1 TR RV NOTES:
CH CHS 208-240V SEE NOTE 3
2
3
1 TR
24V RVC
O-RV
R O
C-RV
W
++ USE N.E.C. CLASS 2 WIRE
DFT DFT2
DFT1 DC R-PS1 Y
PS2
5. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY. 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION
C
CNT
LPS
JUNCTION
P 4 L F 5 1
SEE NOTE 2
1 2 3 4 5
6
TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION
EM C
SWITCH (PRESS.)
C
OVERCURRENT PROT. DEVICE
HPS
FIELD GROUND FIELD SPLICE SWITCH (TEMP) IGNITER
R
W2 W1
Y2
Y1
THERMOSTAT
++
O
G
LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE
FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BL BR GR RD PK PU OR WH YL
BLACK BLUE BROWN GREEN RED PINK PURPLE ORANGE WHITE YELLOW
THERMOSTAT FIELD WIRING
NO ECONOMIZER W
G
WH GR
R
RD
R
Y1
YL
Y
W
G
Y2 C
BL
O
OR
C O STAT
TB1 W G
WH GR
W
R
RD
R
Y1
YL
G Y
Y2 C
BL
O
OR
TB1
C O STAT
2 STAGE COOLING
PLF2 S2
LINE VOLTAGE
WITH ECONOMIZER OPTION
EQUIPMENT GROUND
9 8 7 6 5 4 3 2 1
S1
HPS
FACTORY WIRING
CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR EQUIPMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER REVERSING VALVE
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM "3" AND "4" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. USE COPPER CONDUCTORS ONLY
L
EM G
SS-DSH3
Y1 Y2 R G W1 W2 O C S2 S1
++
GR
R
YL
SEE NOTE 6
BL RD PK CONTROL BOX
RD
BK
BL
LVJB
T3 T1 T2
DFT
BK
N
RD BR
RD
BL
T1
7 BL
PU
12 3 4 5 EM C L G N
C
GR WH WH OR BL
BR
RD
SEE NOTE 2
RD
F
PS2
TB1
1
C
RCCF
Y
YL
GR
YL PU RD
WH
PLF 1
CH
PLF 2 3 6 9 2 5 8 1 4 7 YL
RD
WH
C-RV
OR
GR
YL
BR
BK
0-RV
L1
SEE NOTE 4
PU
BR
2 0 8 BK 2 4 0 RD / 3 / 6 0 BK
C
BK BK
BL
BL
L3
⚡
YL
24V
PK
T3
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
YL/PK
BK
YL
⚠ Warning
YL/PK
BL
BL
BK
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
LPS
3
2
208 240 TR
CHS
RD
BK
BL
++
1 C
RD
BK
RD
C
SEE NOTE 5
www.daikinac.com
208-240/3/60 0140L05411-A
W G
WH GR
R
RD
R
Y1
YL
Y1
Y2
PK
Y2
W G
C
BL
C
O
OR
O STAT
TB1
35
WIRING DIAGRAMS FOR MODELS WITH DDC CONTROLS For complete information and installation instructions for models with DDC controls, see manual DK-DDC-TGD-XXX
36
www.daikinac.com
SS-DSH3
BL
46
GND
COM
GND
VOUT DC
GND
STPT OFFSET
TEMP
VOUT DC GND
24 VAC
OAT
WH WH
WH WH
SS-DSH3 www.daikinac.com Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BL
HPS
C TB2
BL/ PK YL
AG
YL/ PK
GR
BPSW BK
BK
BL
RD BL
GR GR
BR
PU
GR
GND
24VAC
AGND AGND
AI8
AI7
AI6
AI5
AI4
AI3
AI2
AI1
BI8
BI7
BI6
BI5
BI3 BI4
BI2
BI1
BK
⚠ Warning
DFT
RD
YL
LDS CFS
YL/PK RSS
RD
LPS
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
BL
BK GR
RD
BL/PK
PU
PU BK
PU PK
-
ALRM
+
RD
4
1
6
3 ECON
5
2
WH BK BR
RD WH
BK
RD
BL
BK
WH
BK
BK
208-240/3/60 SEE NOTE 2 RD
YL
PU
1
4
7
L1
L2
BK
OR
BL
BK
BK
T1
T2
BK
RD
⚡
GR
C F BR
RCCF
BK
BL
YL
CFC
RD
CC
BL
RD
RD
BK
BR
PU
208-240/3/60
CHS
0140L05811-A
CM
COMP
BC
BR
EM
BL
3 SPEED
TB
PU
PU
RVC
SEE NOTES 7 & 8
BK
HEATER PLF
2
5
8
RD
BK
BK
BR
3
6
9
BK
RD
RD
BL
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
GND GND
+ EXF -
-
AO4
+
GR
BK
RD
POWER SUPPLY
GR BK RD BK RD
HGRH
AO2
WH
WH BR OR BK PK RD
GR
YL
PK
AO3
AO1
COM3-8 COM3-8
RL8
RL6 RL7
RL4 RL5
RL3
RL1 RL2 COM2
COM1
YL
SMK/EMG
BC
L1
DAT
SEE NOTE 5
RD
BL
T1 T2 T3 T4 T5 CS PS ES XS DA
BL
3 240
BL
L2
RD
RD
2 208 TR2 24V
BL
BL
L3
BK
TB1
24V
BL
1 C
RD BK
T1
RD
RD
3 240
BK
PU
L1 T2
24VAC
RD
2 208 TR1 24V
RD
1 C
RD
BK
SEE NOTE 4
L2 T3
VOUT DC
BL
GND
RD
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
T1
CO2
T2
SPCRH SPCTEMP OARH
ING DIAGRAMS Wiring Diagram with DDC— DSH036/DSH048*** (208-230V/3/60) D*** DSH036/DSH048*** [208-230V/3/60] D***
37
L1
38
BR
EM
3 S P E ED
BK
CH
DFT
CFS
LDS
RSS
LPS
BPSW
1
2
DDC
RL2
BI5
RL1
BI3
BI4
BI7
RL5
RL8
RL7
RL6
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
www.daikinac.com AO1
AO4
AO3
AO2
1
6 5 4
CCR1
+ ALRM -
+ - EXF
+ HGRH -
RVC
CFC
L3
⚠ Warning
SEE NOTE 5
BCC/BLS
TR
HEAT ER PLF
SMK/EMG
24V
3
208/240/3/6 0
2
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
GND
24VAC
AGND
AI8
AI7
AI6
AI5
AI4 COM3-8
AI3
AI2
AI1
BI8
RL4
RL3
COM2
COM1
BI6
L2
SEE NOTE 4
CC
TR
3
BC
CM
T3
BI2
BI1
24V
RD
208/240 /3/60
BC
PU
BL
CC
C RCCF F
T2
SEE NOTE 6
COMP
ECON 3 1 PLF 4 2
SPCRH
SPC SENSOR OFFSET TEMP COM
CO2
OARH
OAT
DAT
HPS
PU
TB
CHS
CC T1
SEE NOTE 2 SUPPLY VOLT AGE 208-240/3 /60
COMPONENT LEGE ND
DC GROUND FOR ANALOG SENSORS ("AG" ON TB2) 4 ANALOG OUTPUTS 8 ANALOG INPUTS ALARM BLOWER CONTACTOR BLOWER CONTACTOR COIL 8 BINARY INPUTS BLOWER LOW SPEED BLOWER PROVING SWITCH COMPRESSOR CONTACTOR COMPRESSOR CONTACTOR RELAY CONDENSOR FAN CONTACTOR CLOGGED FILTER SWITCH CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMMON ("C" ON TB2) COMPRESSOR COM1 AND SMOKE DETECTOR DEFROST THERMOSTAT ECONOMIZER TB1-2 TR1-2 XS
RD PU
BC
TABLE 2 RD BL BK
LO W MED HIG H
SPEE D TAPS
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION
ALTERNATE MO T OR 6-W IRES SE E TAB LE 1
RD
TABLE 1 AL TERNATE MOT OR W IRING TER MINAT IO N COLO R T2 (BC) RD BK TB BL TB PU PIN 1 (24V T R2)
⚡
SWITCH (TEMP) TERMINAL
SWI TCH (PRESS.)
JUNC TION OVERCURR ENT PROT. DEV ICE PLUG CONNECTION
IGNITER
FIELD SPLI CE
FIELD GROUND
SCHEMATI C SYMBOL
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
BK
BL
3 SP E ED
BR
DIAGRAM1 EM
HIGH VOLTAGE LOW VOLTAGE
LINE VOLTAGE LOW V OLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING
FACTORY WI RING
EVAPORATOR MOTOR ECON COM3-8,BI1 AND SMOKE DETECTOR EXHAUST FAN EQUIPMENT GROUND HOT GAS REHEAT HIGH PRESSURE SWITCH LOAD SHEDDING LOW PRESSURE SWITCH OUTDOOR AIR TEMPERATURE OUTDOOR AIR RELATIVE HUMIDITY FEMALE PLUG / CONNECTOR HPS, LPS & SMOKE DETECTOR RUN CAPACITOR FOR CONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE COIL SUPPLY / DISCHARGE AIR TEMPERATURE SMOKE OR EMERGENCY SHUTDOWN SPACE TEMPERATURE SPACE RELATIVE HUMIDITY MOTOR SPEED TAPS 1-5 (DIRECT DRIVEN MOTOR ONLY) TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 24 VAC TRANSFORMER & SMOKE DETECTOR
COMPONENT LEGE ND
0140L 05851-A
208-240/3 /60
WIRE CODE BK BLA CK BL BLUE BR BROWN GR GREEN OR ORANGE PK PI NK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STR IP
EM ES EXF GND HGRH HPS LDS LPS OAT OARH PLF PS RCCF RL RSS RVC SAT/DAT SMK/EMG SPCTEMP SPCRH T1-T5
1. REPLA CEMENT WIRE MUST BE SAME SIZE AND TYPE IN SULATION AS ORIGINAL (AT LEAST 105°C) USE CO PPER CONDUCT OR ONLY . 2. USE COPP ER CONDUCT ORS ONLY ++ USE N.E.C. CLASS 2 W IRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMO VE MALE PL UG AND ATT ACH FEMALE PL UG TO THE ECONOMIZER ACCESS ORY. 4. FOR 208 VOLT T RANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO T ERMINAL 2 ON TRANSFORMER. 5. REMO VE JUMPER IF SMOKE DETECTOR OR EMERGENCY SHUTDOWN DEVI CE IS INSTALLED. 6. CRANKCASE HEAT ER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 7. TO CHANGE EVAP M OTOR SPE ED MOVE INTERCHANGE THE RED WIRE ON T2 OF THE BLOWER CONTACTOR WITH EITHER THE BLUE OR BK W IRE ON TB. SEE T ABLE 2. 8. FOR ALTE RNATE M OTOR WIRING SEE DIAGRAM 1.
NOTES:
AO AI ALRM BC BCC BI BLS BPSW CC CCR CFC CFS CH CHS CM COM COMP CS DFT ECON
AGND
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
RING DIAGRAMS Wiring Diagram with DDC — DSH036/DSH048*** (208-230V/3/60)D*** DSH036/DSH048*** [208-230V/3/60] D***
SS-DSH3
RD
3 240
COM
24VAC
GND
GND
VOUT DC
GND
STPT OFFSET
TEMP
GND
VOUT DC
24 VAC
OAT
DAT
WH WH
WH WH
WH
BK
BR
PU YL
SS-DSH3 www.daikinac.com Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BL
C TB2
BL/ PK YL
AG
YL/ PK
GR
DFT
BL
BL
RD BL
GR GR
BR
PU
GND
24VAC
AGND AGND
AI8
AI7
AI6
AI5
AI4
AI3
AI2
AI1
BI8
BI7
BI6
BI5
BI3 BI4
BI2
BI1
WH
BK
GR
RL8
RL6 RL7
RL4 RL5
RL3
RL1 RL2 COM2
COM1
GND GND
AO4
RD
4
1
6
3 ECON
5
2
WH BK BR
BK
BL
BK
RD
WH
BK
BR
WH
208-240/3/60 SEE NOTE 2 RD
9
2
5
8
RD
1
4
7
L2 L1
C
BL
BK
BK
BK
OR
T1
BL
T2
CFC
PU
BK
RD
⚡
RVC
RD
BK
BL
0140L05812-A
CHS
CM
COMP
RD
BK
BR
PU
RD
C L G N
EM
T1 T2 T3 T4 T5
PU WH BR YL OR
208-240/3/60
GR
C F BR
RCCF
BK
YL
BK
RD
YL
BL
BL
SEE NOTE 7
RD
CC
HEATER PLF
3
6
BR
BK
RD
BK
RD
TB
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
-
RD WH
BK
RD
POWER SUPPLY
BK RD BK RD
SMK/EMG
ALRM
+
+ EXF -
-
HGRH
+
PK
AO3
WH
WH BR OR BK PK RD
GR
YL
YL
AO2
AO1
COM3-8 COM3-8
⚠ Warning
BK
RD
YL
GR
PU PK
PU
BK
LDS CFS
YL/PK RSS
RD
LPS
BK BPSW
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
BL
BK GR
RD
BL/PK
HPS
PU
T1 T2 T3 T4 T5 CS PS ES XS DA
OR
SEE NOTE 5
TB1
24V
RD
BR
BK
L1
RD
3 240
BL
L2
RD
2 208 TR2 24V
BK
RD
RD
RD
BL
1 C
BL
RD
L3
VOUT DC
BL
2 208 TR1 24V
RD
GND
BK
T1
BL
BL
1 C
RD
SEE NOTE 4
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
T2
CO2
T3
SPCRH SPCTEMP OARH
NG DIAGRAMS Wiring Diagram with DDC — DSH060*** (208-230V/3/60) D*** DSH060*** [208-230V/3/60] D***
39
L1
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
40
www.daikinac.com
COM
OFFSET
SENSOR
C
EM
L G N
DFT
CFS
LDS
RSS
LPS
BPSW
1
2
RL2
DDC
RL8
RL7
RL6
RL5
RL4
RL3
AO1
AO4
AO3
AO2
1
6
4
5
TR
3
HEATER PLF
SMK/EMG
24V
2
TB1
-
ALRM
+
+ - EXF
-
T5 EM
T3 T2 T1
T4
CCR1
+
CC
L3
⚠ Warning
TB1
C
SEE NOTE 5
HGRH
RVC
CFC
208/240/3 /60
T3
L2
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
GND
24VAC
AGND
AI8
AI7
AI6
AI5
AI4 COM3-8
AI3
AI2
AI1
BI8
BI7
BI6
BI5
RL1
BI3
BI4
COM2
COM1
TR
3
SEE NOTE 4
CM
BI2
BI1
24V
T1 T2 T3 T4 T5
C
CH
208/ 240/3/60
ECON 3 1 PLF 4 2
SPCRH
SPC TEMP
CO2
OARH
OAT
DAT
HPS
TB
H
SEE NOTE 6
F
COMP
RCC F
CHS
CFC T1
CC T1
SEE NOTE 2 SUP PLY VOLTAGE 208-240/3/60 T2 CC
TB1-2 TR1-2 XS
⚡
SWITCH (TEMP) TERMIN AL
SWITCH (PR ESS.)
JUNCTION OVERCUR RENT PROT. DEVICE PLUG CONNECTION
IGNITER
FIELD SPLICE
FIELD GROUND
SCHEMA TIC SYMBO L
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
SEE UN IT RATING PLATE FOR TYPE AND SIZE OF OVER C URRENT PROTECTION
HIGH VOLTAGE LOW VOLTAGE
LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRIN G
FACTORY WIRIN G
EVAPORATOR MOTOR ECON COM3-8,BI1 AND SMOKE DETECTOR EXHAUST FAN EQUIPMENT GROUND HOT GAS REHEAT HIGH PRESSURE SWITCH LOAD SHEDDING LOW PRESSURE SWITCH OUTDOOR AIR TEMPERATURE OUTDOOR AIR RELATIVE HUMIDITY FEMALE PLUG / CONNECTOR HPS, LPS & SMOKE DETECTOR RUN CAPACITOR FOR CONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE COIL SUPPLY / DISCHARGE AIR TEMPERATURE SMOKE OR EMERGENCY SHUTDOWN SPACE TEMPERATURE SPACE RELATIVE HUMIDITY MOTOR SPEED TAPS 1-5 (DIRECT DRIVEN MOTOR ONLY) TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 24 VAC TRANSFORMER & SMOKE DETECTOR
COMPONEN T LEGEND
0140L05852 -A
208-240/3/60
WIRE C ODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PUR PLE RD RED WH WHI TE YL YELLOW BL/PK BLUE WITH PINK STRIPE YL/PK YELLOW WI TH PINK STRIPE
EM ES EXF GND HGRH HPS LDS LPS OAT OARH PLF PS RCCF RL RSS RVC SAT/DAT SMK/EMG SPCTEMP SPCRH T1-T5
1. REPLACEME NT WIRE MU ST BE SAME SIZE A ND TYPE INSULATION AS ORIGINAL (AT LEAS T 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE R ETURN AIR COMPARTMEN T. REMOVE M ALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACC ESSORY. 4. FOR 208 VO LT TRANS FORMER OPERATION MOVE BLACK WIRE F ROM TERMIN AL 3 TO TERMINAL 2 ON TRANS FORMER. 5. REMOVE JUMPER IF SMOKE DETECTOR OR EMERGENCY SHUTDOWN DEVI CE IS INSTALLED. 6. CRANK CASE H EATER AND CRAN KCASE HEATER SWITCH FA CTORY EQUIPPED W HEN REQUIRED. 7. FOR DIFFE RENT THAN FA CTORY SPEED TAP. CH ANGE COOLING SPEED AT MOTOR T4 AND T5 TERMINALS. CHA NGE HEATING SPEED AT MOTOR T1, T2 AND T3. SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REP RESE NTATIVE BUT ACTUAL FACTORY SETTINGS MAY BE DIFFE RENT BASED ON THE HE ATING VALUE OF THE UN IT. COOLING SPEED ( GREEN AND BROWN) T3 - LOW SPEED T4 - HIGH SPEED HEATING SPEED (WHI TE) T1 - LOW SPEED T2 - MED SPEED T5 - HIGH SPEED
NOTES:
COMPONENT LEGEND
DC GROUND FOR ANALOG SENSORS ("AG" ON TB2) 4 ANALOG OUTPUTS AO 8 ANALOG INPUTS AI ALARM ALRM 8 BINARY INPUTS BI BLOWER LOW SPEED BLS BPSW BLOWER PROVING SWITCH COMPRESSOR CONTACTOR CC COMPRESSOR CONTACTOR RELAY CCR CONDENSOR FAN CF CLOGGED FILTER SWITCH CFS CRANKCASE HEATER CH CRANKCASE HEATER SWITCH CHS CONDENSER MOTOR CM COMMON ("C" ON TB2) COM COMP COMPRESSOR COM1 AND SMOKE DETECTOR CS DEFROST THERMOSTAT DFT ECON ECONOMIZER AGND
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring Diagram with DDC — DSH060*** (208-230V/3/60) D*** NG DIAGRAMS DSH060*** [208-230V/3/60] D***
SS-DSH3
BL
52
GND
COM
GND
VOUT DC
GND
STPT OFFSET
TEMP
VOUT DC GND
24 VAC
OAT
SS-DSH3 www.daikinac.com Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
BL
BK GR
BL
C TB2
AG
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
WH WH
YL
YL/ PK
GR
BK
BL
RD BL
GR GR
BR
PU
GR
GND
24VAC
AGND AGND
AI8
AI7
AI6
AI5
AI4
AI3
AI2
AI1
BI8
BI7
BI6
BI5
BI3 BI4
BI2
⚠ Warning
DFT
RD
YL
BK
LDS CFS
YL/PK RSS
RD
LPS
BI1
-
ALRM
+
RD
4
1
3 6 ECON
5
2
WH BK BR
RD WH
BK
RD
BL
WH
BK
BK
BK
9
2
5
BC
BL
PU L2
1
4
7
L1
C
BK
OR
BL
BK
BK
T1
T2
⚡
BK
RD
GR
C F BR
RCCF
BK
CFC
YL
YL
RD
CC
BL
BK
HEATER PLF
3
6
BR 8
RD
BK
BK
WH
BK
RD
RD
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
BK
GND GND
+ EXF -
-
AO4
+
HGRH
AO3
WH
PK RD
WH BR OR BK
GR
YL
AO2
AO1
COM3-8 COM3-8
RL8
RL4 RL5 RL6 RL7
RL3
RL1 RL2 COM2
COM1
PK
OR
L1
WH WH
BL/ PK
BK BPSW
YL
208-240/3/60 SEE NOTE 2 RD
POWER SUPPLY
GR BK RD BK RD
GR
BK
RD
OR
L2
RD
BL/PK
HPS
PU
PU PK
PU BK
SMK/EMG
BL
L3
DAT
SEE NOTE 5
RD
BL
T1 T2 T3 T4 T5 CS PS ES XS DA
BL
3 240
T1
RD
RD
2 208 TR2 24V
BL
T2
C
RD
TB1
24V
BL
1 C
BL
L1 T3
24VAC
RD
RD
3 240
BK
L2
RD
2 208 TR1 24V
BK L3
C
BL
1 C
RD
BL RD BK
T1
VOUT DC
GND
RD
SEE NOTE 4
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
T2
CO2
T3
SPCRH SPCTEMP OARH
0140L05015-B
CM
CHS
208-240/3/60
RVC
RD
RD
BK
BR
PU
COMP
EM
NG DIAGRAMS Wiring Diagram with DDC— DSH036 / DSH048 / DSH060*** (208-230V, 460V, 575V / 3/ 60) B*** DSH036/DSH048/DSH060*** [208-230V/3/60] B***
41
BL
www.daikinac.com
GND
COM
GND
VOUT DC
GND
STPT OFFSET
TEMP
GND
VOUT DC
BL
BK GR
RD
BL
HPS
C TB2
BL/ PK YL
PU
AG
YL/ PK
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
WH WH
OAT
24 VAC
WH WH
RD
BL
SEE NOTE 5
3
240
BK
BL
RD BL
GR GR
BR
PU
BK
RL7
GND
24VAC
AGND
AGND
AI8
AI7
AI6
AI5
AI4
AI3
AI2
AI1
-
ALRM
+
RD
4
1
6
3 ECON
5
2
WH BK BR
RD WH
BK
BL
BK
RD
WH
BK
BK
POWER SUPPLY RD 208-240/1/60 SEE NOTE 2
GR
BK
RD
BR
2
5
8
RD
YL
1
4
7
L1
L2
BK
OR
BL
BK
BK
T1
T2
CFC
BK
BK
⚡
GR
RD
0140L05808-A
CM
CHS
BR
208-240/1/60
RVC
RD
RD
BK
BR
PU
PU
PU
RCCF
COMP
BC
PU BR
EM
TB
3 SPEED
BL
H C F
YL
SEE NOTES 7 & 8
RD
BK
BL
BL
BL
RD
CC
HEATER PLF
3
6
9
BK
BK
RD BK
BC
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
GND GND
+ EXF -
-
AO4
GR BK RD BK RD
HGRH
+
PK
AO3
WH
WH BR OR BK PK RD
GR
YL
YL
SMK/EMG
AO2
AO1
COM3-8
COM3-8
RL8
BI8
BI7
RL6
RL5
RL4
RL3
RL1 RL2 COM2
COM1
BI6
BI5
BI4
BI3
BI2
BI1
⚠ Warning
GR
DFT
RD
YL
GR
PU PK PU BK
BK
LDS CFS
YL/PK RSS
RD
LPS
BK BPSW
T1 T2 T3 T4 T5 CS PS ES XS DA
BL
BL/PK
RD
2
208 TR2 24V
BL
L1
RD
TB1
24V
BL
1
C
BL
L2
DAT
RD
RD
3
240
RD
T1
24VAC
RD
RD
2
208 TR1 24V
BK
BK
BL
L1
BL
1
C
RD
BK
L2 T2
VOUT DC
GND
RD
PU
T1
SPCRH SPCTEMP OARH
42 T2
CO2
SEE NOTE 4
WIRING DIAGRAM WITH DDC – DSH036/048***(208-230V/1/60)D***
SS-DSH3
L1
SS-DSH3
www.daikinac.com
C
BR
EM
3 SPEED
BK
ECON 3 1 PLF 4 2
SPCRH
COM
OFFSET
1
CCR1
+
⚠ Warning
-
ALRM
+
+ - EXF
-
HGRH
RVC
CFC
L2
SEE NOTE 5
BCC/BLS
TR
6 54 HEATER PLF
SMK/EMG
24V
3
208/240/1/60
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
GND
AO4
AO3
AO2
AO1
RL8
RL7
RL6
RL5
RL4
RL3
COM3-8
24VAC
AGND
AI8
AI7
AI6
AI5
CO2
SENSOR
AI4
OARH
AI3
AI2
BI8
BI7
BI6
OAT
SPC TEMP
DDC
RL2
COM2
RL1
BI3
BI4
BI5
COM1
BI1
TR
3
2
SEE NOTE 4
BC
CM
BI2
AI1
DFT
CFS
LDS
RSS
LPS
1
2
24V
RD
208/240/1/60
BPSW
BC
PU
BL
CH
DAT
HPS
PU
TB
CHS
H
SEE NOTE 6
F
COMP
RCCF
CC T1
SEE NOTE 2 SUPPLY VOLTAGE 208-240/1/60 T2 CC
TB1-2 TR1-2 XS
PU
RD
BC
TABLE 2 SPEED TAPS RD LOW BL MED BK HIGH
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION
ALTERNATE MOTOR 6-WIRES SEE TABLE 1
RD
TABLE 1 ALTERNATE MOTOR WIRING COLOR TERMINATION RD T2 (BC) BK TB BL TB PU PIN 1 (24V TR2)
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
BK
BL
EM 3 SPEED
BR
DIAGRAM1
LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE
FACTORY WIRING
EVAPORATOR MOTOR ECON COM3-8,BI1 AND SMOKE DETECTOR EXHAUST FAN EQUIPMENT GROUND HOT GAS REHEAT HIGH PRESSURE SWITCH LOAD SHEDDING LOW PRESSURE SWITCH OUTDOOR AIR TEMPERATURE OUTDOOR AIR RELATIVE HUMIDITY FEMALE PLUG / CONNECTOR HPS, LPS & SMOKE DETECTOR RUN CAPACITOR FOR CONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE COIL SUPPLY / DISCHARGE AIR TEMPERATURE SMOKE OR EMERGENCY SHUTDOWN SPACE TEMPERATURE SPACE RELATIVE HUMIDITY MOTOR SPEED TAPS 1-5 (DIRECT DRIVEN MOTOR ONLY) TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 24 VAC TRANSFORMER & SMOKE DETECTOR
COMPONENT LEGEND
⚡
SWITCH (TEMP) TERMINAL
SWITCH (PRESS.)
JUNCTION OVERCURRENT PROT. DEVICE PLUG CONNECTION
IGNITER
FIELD SPLICE
FIELD GROUND
SCHEMATIC SYMBOL
0140L05848-A
208-240/1/60
WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIPE YL/PK YELLOW WITH PINK STRIPE
EM ES EXF GND HGRH HPS LDS LPS OAT OARH PLF PS RCCF RL RSS RVC SAT/DAT SMK/EMG SPCTEMP SPCRH T1-T5
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. 4. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 5. REMOVE JUMPER IF SMOKE DETECTOR OR EMERGENCY SHUTDOWN DEVICE IS INSTALLED. 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 7. TO CHANGE EVAP MOTOR SPEED MOVE INTERCHANGE THE RED WIRE ON T2 OF THE BLOWER CONTACTOR WITH EITHER THE BLUE OR BK WIRE ON TB. SEE TABLE 2. 8. FOR ALTERNATE MOTOR WIRING SEE DIAGRAM 1.
NOTES:
COMPONENT LEGEND DC GROUND FOR ANALOG SENSORS ("AG" ON TB2) 4 ANALOG OUTPUTS AO 8 ANALOG INPUTS AI ALRM ALARM BLOWER CONTACTOR BC BLOWER CONTACTOR COIL BCC 8 BINARY INPUTS BI BLOWER LOW SPEED BLS BPSW BLOWER PROVING SWITCH COMPRESSOR CONTACTOR CC COMPRESSOR CONTACTOR RELAY CCR CONDENSOR FAN CF CONDENSOR FAN CONTACTOR CFC CLOGGED FILTER SWITCH CFS CRANKCASE HEATER CH CRANKCASE HEATER SWITCH CHS CONDENSER MOTOR CM COMMON ("C" ON TB2) COM COMP COMPRESSOR COM1 AND SMOKE DETECTOR CS DEFROST THERMOSTAT DFT ECON ECONOMIZER AGND
WIRING DIAGRAM WITH DDC – DSH036/048***(208-230V/1/60)D***
43
www.daikinac.com
COM
24VAC
GND
VOUT DC
3
24 VAC
BR
PU
RD
BL
BK GR
RD
BL
HPS
C TB2
BL/ PK YL
PU
AG
YL/ PK
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
GND
VOUT DC
GND
STPT OFFSET
TEMP
GND
VOUT DC
TB1
WH
BL YL
DFT
LDS CFS
BK
RD
YL
BK
BL
RD BL
GR GR
BR
PU
GR
PU PK PU BK
WH
GND
24VAC
AGND
AGND
AI8
AI7
AI6
AI5
AI4
AI3
AI2
AI1
BI8
HGRH
-
ALRM
+
RD
4
1
3 ECON
5 6
2
WH BK BR
RD WH
BK
BL
BK
RD
BR
WH WH
BK
BK
POWER SUPPLY 208-240/1/60 SEE NOTE 2
BK RD BK RD
BK
RD
2
5
8
YL
CC
L2
1
4
7
L1
C
BR
RD
BK
BK
HEATER PLF
3
6
9
BK
RD
RD
TB
BK
OR
BL
BK
BK
T1
T2
CFC
BL
BL
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
GND GND
+ EXF -
-
AO4
+
PK
AO3
WH
WH BR OR BK PK RD
GR
YL
YL
SMK/EMG
AO2
AO1
COM3-8
COM3-8
RL8
BI7
RL6
RL5
RL4
RL3
RL1 RL2 COM2
COM1
BR
RL7
BK
GR
BI6
BI5
BI4
BI3
BI2
BI1
⚠ Warning
GR
BPSW YL/PK RSS
RD
LPS
SEE NOTE 5
T1 T2 T3 T4 T5 CS PS ES XS DA
OR
3
240
BL/PK
BL
24V
RD
WH WH
2
208 TR2 24V
BK
RD
OAT
BL
1
C
WH WH
RD
RD
240
DAT
RD
RD
2
208 TR1 24V
BK
L1
BK
1
C
RD
BL BK
L2
BL
BL
GND
RD
RD
T1
SPCRH SPCTEMP OARH
44 T2
CO2
SEE NOTE 4
⚡
BK
PU
GR
BK
RD YL
BR
CHS
RCCF
0140L05813-A
CM
PU BR
H C F
RD
COMP
BL
C L G N
EM
T1 T2 T3 T4 T5
208-240/1/60
RVC
RD
RD
BK
BR
PU
YL
YL
OR
SEE NOTE 7
BK
RD
WH
WIRING DIAGRAM WITH DDC – DSH060***(208-230V/1/60)D***
SS-DSH3
L1
SS-DSH3
www.daikinac.com
C
EM
L G N
COM
OFFSET
SENSOR
GND
24VAC
AGND
AI8
AI7
AO1
AO4
AO3
AO2
COM3-8
RL8
RL7
RL6
RL5
RL4
RL3
1
6 54 HEATER PLF
SMK/EMG
TR
3
+
TB1
L2
⚠ Warning
-
ALRM
+
+ - EXF
-
HGRH
RVC
T5
EM C
T3 T2 T1
T4
TB1
SEE NOTE 5
CCR1
CFC
208/240/1/60
24V
2
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
ECON 3 1 PLF 4 2
SPCRH
SPC TEMP
AI5
CO2
AI6
AI4
OARH
AI3
AI2
OAT
BI8
BI7
BI6
BI5
RL2 COM2
RL1
BI3
BI4
TR
3
SEE NOTE 4
COM1
DDC
CM
BI2
BI1
24V
2
AI1
DFT
CFS
LDS
RSS
LPS
BPSW
1
208/240/1/60
T1 T2 T3 T4 T5
C
CH
DAT
HPS
H
SEE NOTE 6
F
COMP
RCCF
CHS
TB
CFC
T1
CC T1
SEE NOTE 2 SUPPLY VOLTAGE 208-240/1/60 T2 CC
TB1-2 TR1-2 XS
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION
HIGH VOLTAGE LOW VOLTAGE
LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING
FACTORY WIRING
EVAPORATOR MOTOR ECON COM3-8,BI1 AND SMOKE DETECTOR EXHAUST FAN EQUIPMENT GROUND HOT GAS REHEAT HIGH PRESSURE SWITCH LOAD SHEDDING LOW PRESSURE SWITCH OUTDOOR AIR TEMPERATURE OUTDOOR AIR RELATIVE HUMIDITY FEMALE PLUG / CONNECTOR HPS, LPS & SMOKE DETECTOR RUN CAPACITOR FOR CONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE COIL SUPPLY / DISCHARGE AIR TEMPERATURE SMOKE OR EMERGENCY SHUTDOWN SPACE TEMPERATURE SPACE RELATIVE HUMIDITY MOTOR SPEED TAPS 1-5 (DIRECT DRIVEN MOTOR ONLY) TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 24 VAC TRANSFORMER & SMOKE DETECTOR
COMPONENT LEGEND
⚡
SWITCH (TEMP) TERMINAL
SWITCH (PRESS.)
JUNCTION OVERCURRENT PROT. DEVICE PLUG CONNECTION
IGNITER
FIELD SPLICE
FIELD GROUND
SCHEMATIC SYMBOL
0140L05853-A
208-240/1/60
WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIPE YL/PK YELLOW WITH PINK STRIPE
EM ES EXF GND HGRH HPS LDS LPS OAT OARH PLF PS RCCF RL RSS RVC SAT/DAT SMK/EMG SPCTEMP SPCRH T1-T5
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. 4. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 5. REMOVE JUMPER IF SMOKE DETECTOR OR EMERGENCY SHUTDOWN DEVICE IS INSTALLED. 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 7. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING SPEED AT MOTOR T4 AND T5 TERMINALS. CHANGE HEATING SPEED AT MOTOR T1, T2 AND T3. SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REPRESENTATIVE BUT ACTUAL FACTORY SETTINGS MAY BE DIFFERENT BASED ON THE HEATING VALUE OF THE UNIT. COOLING SPEED (GREEN AND BROWN) T3 - LOW SPEED T4 - HIGH SPEED HEATING SPEED (WHITE) T1 - LOW SPEED T2 - MED SPEED T5 - HIGH SPEED
NOTES:
COMPONENT LEGEND
DC GROUND FOR ANALOG SENSORS ("AG" ON TB2) 4 ANALOG OUTPUTS AO 8 ANALOG INPUTS AI ALRM ALARM 8 BINARY INPUTS BI BLOWER LOW SPEED BLS BPSW BLOWER PROVING SWITCH COMPRESSOR CONTACTOR CC COMPRESSOR CONTACTOR RELAY CCR CONDENSOR FAN CF CONDENSOR FAN CONTACTOR CFC CLOGGED FILTER SWITCH CFS CRANKCASE HEATER CH CRANKCASE HEATER SWITCH CHS CONDENSER MOTOR CM COMMON ON TB2) ("C" COM COMP COMPRESSOR COM1 AND SMOKE DETECTOR CS DEFROST THERMOSTAT DFT ECON ECONOMIZER AGND
WIRING DIAGRAM WITH DDC – DSH060***(208-230V/1/60)D***
45
Accessories
Daikin Master Item #
Description
Fits Model Sizes
FieldInstalled
FactoryInstalled
Operating Weight (lbs)
Curb 14CURB3672B
14” Roof Curb
3-5 Tons
√
86
18CURB3672B
18” Roof Curb
3-5 Tons
√
100
24CURB3672B
24” Roof Curb
3-5 Tons
√
128
GHRC-3672
Hurricane Restraint Clips
3-5 Tons
√
2
Ultra Low-Leak Economizer & Power Exhaust
1
10-365-09C
Ultra Low-Leak Downflow Economizer w/ Dry Bulb
3-5 Tons
√
10-366-09C
Ultra Low-Leak Downflow Economizer w/ Enthalpy
3-5 Tons
√
71
10-395-09
Ultra Low-Leak Horizontal Economizer w/ Dry Bulb
3-5 Tons
√
71
10-396-09
Ultra Low-Leak Horizontal Economizer w/ Enthalpy
3-5 Tons
√
71
10-455-09*-23
Centrifugal Power Exhaust 230v
3-5 Tons
√
55
10-455-09*-33
Centrifugal Power Exhaust 460v
3-5 Tons
√
55
10-455-09*-43
Centrifugal Power Exhaust 575v
3-5 Tons
√
55
10-457-09xA-23
Modulating Power Exhaust 208-230v
3-5 Tons
√
55
10-457-09xA-33
Modulating Power Exhaust 460v
3-5 Tons
√
55
10-465-09-21
Prop Power Exhaust 230v
3-5 Tons
√
55
10-465-09-31
Prop Power Exhaust 460v
3-5 Tons
√
55
10-465-09-41
Prop Power Exhaust 575v
3-5 Tons
√
55
√
71
Low-Leak Economizer & Power Exhaust
2
DDNECNJ3672C
Low-Leak Downflow Economizer
3-5 Tons
√
√
82
DPE36722
Downflow Power Exhaust (208/230 Volt)
3-5 Tons
√
55
DPE36724
Downflow Power Exhaust (460 Volt)
3-5 Tons
√
55
DPE36727
Downflow Power Exhaust (575v)
3-5 Tons
√
55
DHZECNJ3672
Horizontal Economizer
3-5 Tons
√
70
DHPE36722
Horizontal Power Exhaust (208/230 Volt)
3-5 Tons
√
55
DHPE36724
Horizontal Power Exhaust (460 Volt)
3-5 Tons
√
55
DHPE36727
Horizontal Power Exhaust (575 Volt)
3-5 Tons
√
55
Downflow Accessories D25FD3672
25% Manual Fresh Air Damper
3-5 Tons
√
12
D25MFD3672
25% Motorized Fresh Air Damper
3-5 Tons
√
16
DDNBBS3672
Burglar Bar Sleeves with Supply & Return
3-5 Tons
√
30
DDNECNJ3672NR
Downflow Economizer2 w/o Barometric Relief
3-5 Tons
√
77
DDNSQRD3616
Downflow Square-to-Round Adapter (16” Round)
3 tons
√
45
4-5 tons
√
35
3-5 Tons
√
15
DDNSQRD487218 Downflow Square-to-Round Adapter (18” Round) Horizontal Accessories DBRD3672
Barometric Relief Damper Concentrics
CDK36
Concentric Duct Kit
3 Ton
√
27
CDK36515
Flush Mount Concentric Duct Kit w/ Filter
3 Ton
√
28
CDK36530
Step Down Concentric Duct Kit
3 Ton
√
27
CDK36535
Step Down Concentric Duct Kit w/ Filter
3 Ton
√
28
46
www.daikinac.com
SS-DSH3
Accessories (cont.) Daikin Master Item #
Description
Fits Model Sizes
FieldInstalled
FactoryInstalled
Operating Weight (lbs)
CDK4872
Concentric Duct Kit
4-5 Ton
√
27
CDK4872515
Flush Mount Concentric Duct Kit w/ Filter
4-5 Ton
√
28
CDK4872530
Step Down Concentric Duct Kit
4-5 Ton
√
27
CDK4872535
Step Down Concentric Duct Kit w/ Filter
4-5 Ton
√
28
DDC Accessories
3
DDC communicating controller (built-in BACnet® MS/TP) includes Standard Room Sensor to be installed in field
3-5 Tons
√
2
10366D09C
DDC Ultra Low-Leak Downflow Economizer
3-5 Tons
√
√
71
10366D09
DDC Ultra Low-Leak Horizontal Economizer
3-5 Tons
√
71
10465DDC
Power Exhaust kit used with DDC Ultra Low-Leak Economizer
3-5 tons
√
1
DLAKT01
Low-Ambient
3-5 Tons
√
LONKT01
LonWorks® card
3-5 Tons
√
3PMK01
Phase Monitor (3-Phase Only)
3-5 Tons
√
DFSKT01
Dirty Filter Switch
3-5 Tons
√
√
2 1
√
2 1
1 phase 208-230V Electric Heat Kits SPKT01
Single Point Wiring Kit 1phase Heat Kits
3-5 Tons
√
√
3
EHK1-10
10kw 208-230v 1ph Electric Heat Kit
3-5 Tons
√
√
21
EHK1-15
15kw 208-230v 1ph Electric Heat Kit
3-5 Tons
√
√
21
EHK1-18
18kw 208-230v 1ph Electric Heat Kit
4 tons
√
√
21
EHK1-20
20kw 208-230v 1ph Electric Heat Kit
5 tons
√
√
21
3 phase 208-230V Electric Heat Kits SPKT02
Single Point Wiring Kit 3phase Heat Kits
3-5 Tons
√
√
3
EHK3-10
10kw 208-230 3ph Electric Heat Kit
3-5 Tons
√
√
21
EHK3-15
15kw 208-230 3ph Electric Heat Kit
3-5 Tons
√
√
21
EHK3-18
18kw 208-230 3ph Electric Heat Kit
4 tons
√
√
21
EHK3-20
20kw 208-230 3ph Electric Heat Kit
5 tons
√
√
21
3 phase 460V Electric Heat Kits EHK4-10
10kw 460v 3ph Electric Heat Kit
3-5 Tons
√
√
21
EHK4-15
15kw 460v 3ph Electric Heat Kit
3-5 Tons
√
√
21
EHK4-18
18kw 460v 3ph Electric Heat Kit
4 tons
√
√
21
EHK4-20
20kw 460v 3ph Electric Heat Kit
5 tons
√
√
21
3 phase 575V Electric Heat Kits EHK7-10
10kw 575v 3ph Electric Heat Kit
3-5 Tons
√
√
21
EHK7-15
15kw 575v 3ph Electric Heat Kit
3-5 Tons
√
√
21
EHK7-18
18kw 575v 3ph Electric Heat Kit
4 tons
√
√
21
EHK7-20
20kw 575v 3ph Electric Heat Kit
5 tons
√
√
21
High-Static Kits4 HSKTS036
High Static Kit - 230v & 460v
DS*, 3 Ton
√
√
2
HSKTS048
High Static Kit - 230v & 460v
DS*, 4 Ton
√
√
38
HSKTS060
High Static Kit - 230v & 460v
DS*, 5 Ton
√
√
38
SS-DSH3
www.daikinac.com
47
Accessories (cont.) Daikin Master Item #
Description
Fits Model Sizes
FieldInstalled
FactoryInstalled
Operating Weight (lbs)
HSKTS036-7
High Static Kit - 575v
DS*, 3 Ton
√
√
2
HSKTS048-7
High Static Kit - 575v
DS*, 4 Ton
√
√
5
HSKTS060-7
High Static Kit - 575v
DS*, 5 Ton
√
√
38
Crankcase Heater Kits 0163R00002S
40W 230V
3 tons
√
1
0163R00031S
40W 460V
3 tons
√
1
0163R00032S
40W 575V
3 tons
√
1
0130L00017S
70W 230V
4 - 5 tons
√
1
0130L00018S
70W 460V
4 - 5 tons
√
1
0130L00019S
70W 575V
4 - 5 tons
√
1
High Efficiency Filters 0160L00203
High Efficiency MERV 13 Air Filter Nom. Size: 24x24x2; (Order Qty 1)
3 tons
√
2
0160L00204
High Efficiency MERV 13 Air Filter Nom. Size: 14x20x2; (Order Qty 4)
4 tons
√
4
0160L00205
High Efficiency MERV 13 Air Filter Nom. Size: 16x20x2; (Order Qty 4)
5 tons
√
4
Condenser Coil Hail Guard
3-5 tons
√
19
Convenience Outlet: Non Powered
3-5 tons
√
2
Convenience Outlet: Powered
3-5 tons
√
42
Misc Accessories HAILGD03D
Disconnect Switch
3-5 tons
√
5
LAKT11
Low Ambient Kit, 208-230V - non-DDC
3-5 tons
√
√
14
LAKT13
Low Ambient Kit, 460V - non-DDC
3-5 tons
√
√
14
LAKT14
Low Ambient Kit, 575V - non-DDC
3-5 tons
√
√
14
3PMNDK01
Phase Monitor - Non DDC
3-5 Ton
√
√
2
Smoke Detector (supply and/or return air)
3-5 Ton
√
11
Hinged Panels
3-5 Ton
√
10
FSK01A
Freeze Stat Kit
3-5 Ton
√
1
IRKT-01
Isolation Relay Kit
3-5 Ton
√
2
Use Economizer & Power Exhaust listed within Ultra Low-Leak section 2 Use Economizer & Power Exhaust listed within Low-Leak section 3 For a full list of DDC accessories, pleas e refer to DDC Controller Technical Guide manual (DK-DDC-TGD-01B) 4 HSKT High-Static Kits are for use with standard single-speed belt-drive units only. Note: Where multiple variations are available, the heaviest combination is listed. 1
Our continuing commitment to quality products may mean a change in specifications without notice. © 2017 • Houston, Texas • Printed in the USA.
48
www.daikinac.com
SS-DSH3