Dsh Commercial

   EMBED


Share

Transcript

DSH Commercial 3 - 5 Tons Packaged Heat Pumps 14 SEER / Up to 12 EER 8.0 HSPF Cooling Capacity: 36,000 — 60,000 BTU/h Heating Capacity: 36,000 — 57,000 BTU/h ■ Contents Nomenclature......................................... 2 Product Specifications............................ 4 Expanded Cooling Data.......................... 7 Airflow Data.......................................... 13 Crankercase Heater ............................. 21 Expanded Heating Data ....................... 22 Heat Kit Electrical Data ........................ 23 Dimensions........................................... 26 Wiring Diagrams .................................. 30 – for Models with DDC Controls............... 36 Accessories .......................................... 46 ■ Standard Features • • • • • • • • • • • • • • High-efficiency scroll compressor Copper tube / aluminum fin coils High- and low-pressure switches Refrigerant accumulator Contactor with lugs High-capacity, steel-cased filter drier Heater kits with single-point entry 24-volt terminal strip Convertible airflow orientation Easy to service Built-in filter rack with standard 2" filters Bottom utility entry AHRI Certified; ETL Listed 3-5 Tons with single speed blower motor units meet the performance specified in Table 6.8.1-2 of ASHRAE Standard 90.1-2013 ■ Cabinet Features • Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish • Full Perimeter Rail • Sloped drain pan * Complete warranty details available from your local distributor or manufacturer’s representative or at www.daikincomfort.com. SS-DSH3 www.daikinac.com 4/17 Supersedes 2/17 Nomenclature D 1 S 2 H 3 060 4,5,6 020 7,8,9 3 10 B 11 * 12 * 13 * 14 A * 15 16 Revision Levels Major & Minor Brand D Daikin X A B C D E F Configuration C Standard Efficiency (6 - 25 Tons) S Standard Efficiency (3 - 5 Tons) T High Efficiency (3 - 5 Tons) Application C Cooling1 G Gas Heat H Heat Pump1 Nominal Cooling Capacity 036 3 Tons 102 048 4 Tons 120 060 5 Tons 150 072 6 Tons 180 090 7½ Tons 240 G H J 8½ Tons 10 Tons 12½ tons 15 Tons 20 Tons 300 25 Tons K L Nominal Heating Capacity Gas/Electric A/C H/P Factory-Installed Electric Heat 045 45,000 BTU/h XXX No Heat 090 90,000 BTU/h 010 10 kW 030 30 kW 115 115,000 BTU/h 015 15 kW 031 30 kW 140 140,000 BTU/h 016 15 kW 045 45 kW 210 210,000 BTU/h 018 18 kW 046 45 kW 350 350,000 BTU/h 020 20 kW 060 60 kW 400 400,000 BTU/h 025 25 kW See product specifications for heat size(s) available for each capacity. M N O P Q R Voltage 1 208-230/1/60 3 208-230/3/60 4 7 460/3/60 575/3/60 T U Supply Fan/Drive Type/Motor B Belt Drive (single speed) V Two-Speed Belt Drive (also designates 6-Ton D Direct Drive (3-5 Tons) with two-stage compressor) H High Static (single-speed Belt Drive models only) Factory-Installed Options A Ultra Low-Leak Downflow Economizer R Ultra Low-Leak Downflow Economizer; B DDC-BACnet protocol DDC-BACnet protocol; F Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) DDC-BACnet protocol V Low-Leak Downflow Economizer H Disconnect Switch (non-fused) W Low-Leak Downflow Economizer J Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) Disconnect Switch (non-fused) X No Options M Disconnect Switch (non-fused); DDC-BACnet protocol Note: Not all options available for all products. X= No Options in character 13th 1 2 www.daikinac.com V W Y Z Factory-Installed Options No Options Non-powered convenience outlet Powered convenience outlet Low-ambient kit Return air smoke detector Supply air smoke detector Non-powered convenience outlet; Low-ambient kit Non-powered convenience outlet; Return air smoke detector Non-powered convenience outlet; Supply air smoke detector Non-powered convenience outlet; Return & Supply air smoke detectors Non-powered convenience outlet; Low-ambient kit; Supply air smoke detector Non-powered convenience outlet; Low-ambient kit Return & Supply air smoke detectors Powered convenience outlet; Low-ambient kit Powered convenience outlet; Return air smoke detector Powered convenience outlet; Return & Supply air smoke detectors Powered convenience outlet; Supply air smoke detector Powered convenience outlet; Low-ambient kit; Return air smoke detector Powered convenience outlet; Low-ambient kit; Supply air smoke detector Powered convenience outlet; Low-ambient kit; Return & Supply air smoke detectors Non-powered convenience outlet; Low-ambient kit; Return air smoke detector Low-ambient kit; Return air smoke detector Low-ambient kit; Supply air smoke detector Low-ambient kit; Return & Supply air smoke detectors Return & Supply air smoke detectors Factory-Installed Options Standard Aluminized Heat Exchanger Stainless-Steel Heat Exchanger Hinged Panels Stainless-Steel Heat Exchanger; Hinged Panels B Phase Monitor J Stainless Steel Heat Exchanger; Phase Monitor M Hinged Panel; Phase Monitor L Stainless-Steel Heat Exchanger; Hinged Panels; Phase Monitor X S D K SS-DSH3 Nomenclature Factory-Installed Options • Stainless-Steel Heat Exchanger (Gas only units): A tubular heat exchanger made of 409-type stainless steel is installed in the unit. • Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3- to 6-ton units, cooling operation is extended from 60°F ambient temperature to 35°F outside air temperature. On 7½ -20 ton units, cooling operation is extended from 35°F ambient temperature to 0°F outside air temperature. For 25 ton units, cooling operation is extended from 24°F ambient temperature to 0°F outside air temperature. • Economizers (Downflow): Based on air conditions, can provide outside air to cool the space. • Electric Heat Kits (A/C and Heat Pump units only): Available in all voltage options. • Non-powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. • Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit. When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.5A for 208/230V units, increase by 3.75A for 460V units, and by 3A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. • Disconnect Switch (non-fused; 3-phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit.  Please note that for air conditioning and heat pump models, the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered.  Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. • Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit. • Hinged Access Panels: Allows access to unit’s major components. Combined with latches for easy access to control box, compressor, filters and blower motor. Available on all units. • Two-speed indoor fan blower models are available on 6, 7½, 8½, 10, 12½, 15, 20 & 25 ton units. Section 6.4.3.10.b of ASHRAE Standard 90.1-2010 and Section 6.5.3.2.1.a of ASHRAE Standard 90.1-2013 require a minimum of two fan speeds. Section 140.4(m)1 of California Energy Commission Title 24 2013 contains a similar provision. When the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling, the fan operates at low speed, which is 66% of full speed. When the units operate on a call for the second stage of cooling, the fan operates at full speed. In heating operation, the fan operates at full speed. During ventilation operation, the fan operates at low speed. • Phase Monitor: Phase monitor (3 phase only), available for 3 - 25 ton DS, DC and DT series models. Phase monitor shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. • DDC Controller: DDC communicating controller, available for 3 - 25 ton DS, DC and DT series models with on-board BACnet® communication interface. SS-DSH3 www.daikinac.com 3 Product Specifications — 3 Tons Cooling Capacity Total BTU/h Sensible BTU/h SEER / EER Decibels AHRI Reference #s Heating Capacity BTU/h / COP (47° F) BTU/h / COP (17° F) HSPF Evaporator Motor / Coil Motor Type Indoor Nominal CFM Motor Speed Tap (Cooling) Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Filter Size (") Drain Size (NPT) R-410A Refrigerant Charge Cir #1 (oz.) Evaporator Coil Face Area (ft²) Rows Deep / Fins per Inch Belt Drive Evap Fan Data # of Wheels (D x W) Motor Sheave Blower Sheave / Belt Condenser Fan / Coil Quantity of Condenser Fan Motors Horsepower - RPM Fan Diameter/ # Fan Blades Outdoor Nominal CFM Face Area (ft²) Rows Deep/ Fins per Inch Piston Size (Heating) Compressor Quantity / Type/ Stage Compressor RLA / LRA Electrical Data Voltage-Phase-Frequency Indoor Blower HP / FLA Max External Static Outdoor Fan HP / FLA Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² Power Supply Conduit Hole Low-Voltage Conduit Hole Operating Weight (lbs) Ship Weight (lbs) DSH036 ***1D***A* DSH036 ***3D***A* DSH036 ***3B***A* DSH036 ***4B***A* DSH036 ***7B***A* 36,000 26,600 14 / 12 78 9967138 36,000 26,600 14 / 12 78 9967141 36,000 26,600 14 / 12 78 9952135 36,000 26,600 14 / 12 78 9952137 36,000 26,600 14 / 12 78 9952139 36,000 / 3.6 19,000 / 2.3 8.0 36,000 / 3.6 19,000 / 2.3 8.0 36,000 / 3.6 19,000 / 2.3 8.0 36,000 / 3.6 19,000 / 2.3 8.0 36,000 / 3.6 19,000 / 2.3 8.0 Direct Drive 1,250 LOW 2.46 ⅓ - 910 0.068 (4) 14" x 20" x 2" ¾" 158 7.0 4 / 16 Direct Drive 1,250 LOW 2.46 ⅓ - 910 0.068 (4) 14" x 20" x 2" ¾" 158 7.0 4 / 16 Belt Drive 1,200 --3.4 1.0 - 1725 0.068 (4) 14" x 20" x 2" ¾" 170 7.0 4 / 16 Belt Drive 1,200 --1.7 1.0 - 1725 0.068 (4) 14" x 20" x 2" ¾" 170 7.0 4 / 16 Belt Drive 1,200 --2.3 1.5 - 1725 0.068 (4) 14" x 20" x 2" ¾" 170 7.0 4 / 16 ------------- ------------- 1 (11" x 10") 1VL34 x ⅝ AK61 x 1 / AX51 1 (11" x 10") 1VL34 x ⅝ AK61 x 1 / AX51 1 (11" x 10") 1VL34 x ⅝ AK61 x 1 / AX51 1 ¼ - 1,075 22 / 4 3,800 17.0 2 / 18 0.053 1 ¼ - 1,075 22 / 4 3,800 17.0 2 / 18 0.053 1 ¼ - 1,075 22 / 4 3,800 17.0 2 / 18 0.053 1 ¼ - 1075 22 / 4 3,800 17.0 2 / 18 0.053 1 ¼ - 1,075 22 / 4 3,800 17.0 2 / 18 0.053 1 / Scroll / Single 16.7 / 79.0 1 / Scroll / Single 10.4 / 73.0 1 / Scroll / Single 10.5 / 73.0 1 / Scroll / Single 5.8 / 38.0 1 / Scroll / Single 3.8 / 36.5 208/230-1-60 ⅓ / 2.46 0.5" ¼ / 1.4 25 40 1.125" ½" 580 605 208/230-3-60 ⅓ / 2.46 0.5" ¼ / 1.4 17 25 1.125" ½" 580 605 208/230-3-60 1.0 / 3.4 1.0" ¼ / 1.4 18 25 1.125 ½" 580 605 460-3-60 1.0 / 1.7 1.0" ¼ / 0.7 10 15 1.125 ½" 580 605 575-3-60 1.5 / 2.3 1.0" ¼ / 0.55 8 15 1.125 ½" 580 605 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed. 4 www.daikinac.com SS-DSH3 Product Specifications — 4 Tons Cooling Capacity Total BTU/h Sensible BTU/h SEER / EER Decibels AHRI Reference #s Heating Capacity BTU/h / COP (47° F) BTU/h / COP (17° F) HSPF Evaporator Motor / Coil Motor Type Indoor Nominal CFM Motor Speed Tap (Cooling) Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Filter Size (") Drain Size (NPT) R-410A Refrigerant Charge Cir #1 (oz.) Evaporator Coil Face Area (ft²) Rows Deep / Fins per Inch Belt Drive Evap Fan Data # of Wheels (D x W) Motor Sheave Blower Sheave / Belt Condenser Fan / Coil Quantity of Condenser Fan Motors Horsepower - RPM Fan Diameter/ # Fan Blades Outdoor Nominal CFM Face Area (ft²) Rows Deep/ Fins per Inch Piston Size (Heating) Compressor Quantity / Type/ Stage Compressor RLA / LRA Electrical Data Voltage-Phase-Frequency Indoor Blower HP / FLA Max External Static Outdoor Fan HP / FLA Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² Power Supply Conduit Hole Low-Voltage Conduit Hole Operating Weight (lbs) Ship Weight (lbs) DSH048 ***1D***A* DSH048 ***3D***A* DSH048 ***3B***A* DSH048 ***4B***A* DSH048 ***7B***A* 48,000 35,520 14 / 12 78 9967139 48,000 35,520 14 / 12 78 9967142 46,500 34,875 14 / 12 78 9956243 46,500 34,875 14 / 12 78 9956244 46,500 34,875 14 / 12 78 9956245 45,000 / 3.6 25,000 / 2.3 8.0 45,000 / 3.6 25,000 / 2.3 8.0 45,500 / 3.6 25,000 / 2.3 8.0 45,500 / 3.6 25,000 / 2.3 8.0 45,500 / 3.6 25,000 / 2.3 8.0 Direct Drive 1,650 MED 2.8 ¾ -1,025 0.076 (4) 14" x 20" x 2" ¾" 178 7.8 4 / 16 Direct Drive 1,650 MED 2.8 ¾ -1,025 0.076 (4) 14" x 20" x 2" ¾" 178 7.8 4 / 16 Belt Drive 1,600 --3.4 1.0 - 1,725 0.076 (4) 14" x 20" x 2" ¾" 173 7.8 4 / 16 Belt Drive 1,600 --1.7 1.0 - 1,725 0.076 (4) 14" x 20" x 2" ¾" 173 7.8 4 / 16 Belt Drive 1,600 --2.3 1.5 - 1,725 0.076 (4) 14" x 20" x 2" ¾" 173 7.8 4 / 16 ------------- ------------- 1 (11" x 10") VL40 x ⅝ AK66 x 1 / AX52 1 (11" x 10") VL40 x ⅝ AK66 x 1 / AX52 1 (11" x 10") VL40 x ⅝ AK66 x 1 / AX52 1 ¼ / 1,075 22 / 4 3,800 17 2 / 18 0.057 1 ¼ / 1,075 22 / 4 3,800 17 2 / 18 0.057 1 ¼ / 1,075 22 / 4 3,800 17 2 / 18 0.057 1 ¼ / 1,050 22 / 4 3,800 17 2 / 18 0.057 1 ¼ / 1,050 22 / 4 3,800 17 2 / 18 0.057 1 / Scroll / Single 19.9 / 109 1 / Scroll / Single 13.1/ 83.1 1 / Scroll / Single 13.1 / 83.1 1 / Scroll / Single 6.1 / 41 1 / Scroll / Single 4.4 / 33 208/230-1-60 ¾ / 2.8 0.5" ¼ / 1.4 29 45 1.125" ½" 585 610 208/230-3-60 ¾ / 2.8 0.5" ¼ / 1.4 21 30 1.125" ½" 585 610 208/230-3-60 1.0 / 3.4 1.0" ¼ / 1.4 21 30 1.125 ½" 585 610 460-3-60 1.0 / 1.7 1.0" ¼ / 0.7 10 15 1.125 ½" 585 610 575-3-60 1.5 / 2.3 1.0" ¼ / 0.55 8 15 1.125 ½" 585 610 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed. SS-DSH3 www.daikinac.com 5 Product Specifications — 5 Tons Cooling Capacity Total BTU/h Sensible BTU/h SEER / EER Decibels AHRI Reference #s Heating Capacity BTU/h / COP (47° F) BTU/h / COP (17° F) HSPF Evaporator Motor / Coil Motor Type Indoor Nominal CFM Motor Speed Tap (Cooling) Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Filter Size (") Drain Size (NPT) R-410A Refrigerant Charge Cir #1 (oz.) Evaporator Coil Face Area (ft²) Rows Deep / Fins per Inch Belt Drive Evap Fan Data # of Wheels (D x W) Motor Sheave Blower Sheave / Belt Condenser Fan / Coil Quantity of Condenser Fan Motors Horsepower - RPM Fan Diameter/ # Fan Blades Outdoor Nominal CFM Face Area (ft²) Rows Deep/ Fins per Inch Piston Size (Heating) Compressor Quantity / Type/ Stage Compressor RLA / LRA Electrical Data Voltage-Phase-Frequency Indoor Blower HP / FLA Max External Static Outdoor Fan HP / FLA Min. Circuit Ampacity¹ Max. Overcurrent Protection (amps)² Power Supply Conduit Hole Low-Voltage Conduit Hole Operating Weight (lbs) Ship Weight (lbs) DSH060 ***1D***A* DSH060 ***3D***A* DSH060 ***3B***A* DSH060 ***4B***A* DSH060 ***7B***A* 60,000 44,000 14 / 12 78 9967140 60,000 44,000 14 / 12 78 9967143 60,000 44,000 14 / 12 78 9952136 60,000 44,000 14 / 12 78 9952138 60,000 44,000 14 / 12 78 9952140 57,000 / 3.6 32,000 / 2.4 8.0 57,000 / 3.6 32,000 / 2.4 8.0 57,000 / 3.6 32,000 / 2.3 8.0 57,000 / 3.6 32,000 / 2.3 8.0 57,000 / 3.6 32,000 / 2.3 8.0 Direct Drive 2,000 T3 6.90 1.0 - 1050 0.086 (4) 16" x 20" x 2" ¾" 254 8.9 4 / 16 Direct Drive 2,000 T3 6.90 1.0 - 1050 0.086 (4) 16" x 20" x 2" ¾" 254 8.9 4 / 16 Belt 1,800 --3.0 1.0 - 1,760 0.089 (4) 16" x 20" x 2" ¾" 230 8.9 4 / 16 Belt 1,800 --1.5 1.0 - 1,760 0.089 (4) 16" x 20" x 2" ¾" 230 8.9 4 / 16 Belt 1,800 --1.2 1.0 - 1,760 0.089 (4) 16" x 20" x 2" ¾" 230 8.9 4 / 16 ------------- ------------- 1 (11" x 10") VL44 x ⅞ AK66 x 1 / AX52 1 (11" x 10") VL44 x ⅞ AK66 x 1 / AX52 1 (11" x 10") VL44 x ⅞ AK66 x 1 / AX52 1 ⅓ - 1,075 22 / 4 4,200 18.7 2 / 20 0.062 1 ⅓ - 1,075 22 / 4 4,200 18.7 2 / 20 0.062 1 ⅓ - 1,075 22 / 4 4,200 18.7 2 / 20 0.068 1 ⅓ - 1,075 22 / 4 4,200 18.7 2 / 20 0.068 1 ⅓ - 1,075 22 / 4 4,200 18.7 2 / 20 0.068 1 / Scroll / Single 26.4 / 134.0 1 / Scroll / Single 16.0 / 110.0 1 / Scroll / Single 16 .0/ 110.0 1 / Scroll / Single 7.8 / 52 1 / Scroll / Single 5.7 / 38.9 208/230-1-60 1 / 6.9 0.9" ⅓ / 2.0 40.2 60 1.125" ½" 650 675 208/230-3-60 1 / 6.9 0.9" ⅓ / 2.3 29 45 1.125" ½" 650 675 208/230-3-60 1.0 / 3.0 1.0 ⅓ / 2.3 25.5 40 1.125 ½" 650 675 460-3-60 1.0 / 1.5 1.0 ⅓ / 1.1 12.3 20 1.125 ½" 650 675 575-3-60 1.0 / 1.2 1.0 ⅓ / 0.9 9.2 15 1.125 ½" 650 675 ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed. 6 www.daikinac.com SS-DSH3 SS-DSH3 www.daikinac.com 59 36.7 0.74 19 2.37 6.7 230 111 35.6 0.71 19 2.35 6.6 228 110 32.8 0.68 20 2.30 6.5 221 107 37.3 0.84 21 2.39 6.7 232 112 36.2 0.80 22 2.37 6.7 230 111 33.4 0.77 23 2.32 6.5 223 108 Airflow MBh S/T Delta T 1350 KW AMPS HI PR LO PR MBh S/T Delta T KW 1200 AMPS HI PR LO PR MBh S/T Delta T KW 1050 AMPS HI PR LO PR MBh S/T Delta T 1350 KW AMPS HI PR LO PR MBh S/T Delta T 1200 KW AMPS HI PR LO PR MBh S/T Delta T 1050 KW AMPS HI PR LO PR 38.4 0.75 20 2.44 6.9 250 119 37.3 0.72 21 2.42 6.8 247 118 34.4 0.69 21 2.36 6.6 240 115 63 38.0 0.62 16 2.42 6.8 247 118 36.9 0.59 17 2.40 6.8 245 117 34.0 0.57 17 2.35 6.6 238 113 41.5 0.57 16 2.51 7.1 264 130 40.3 0.54 17 2.49 7.0 261 129 37.2 0.52 17 2.44 6.8 254 125 67 41.6 0.43 12 2.49 7.0 261 129 40.4 0.41 13 2.47 6.9 259 128 37.3 0.39 13 2.42 6.8 251 124 44.6 0.37 11 2.59 7.3 275 139 43.3 0.35 12 2.57 7.2 273 137 40.0 0.34 12 2.51 7.1 264 133 71 36.4 0.87 22 2.57 7.2 261 119 35.3 0.83 23 2.55 7.1 258 117 32.6 0.80 23 2.49 7.0 250 114 59 35.8 0.77 19 2.55 7.1 258 117 34.8 0.73 20 2.53 7.1 255 116 32.1 0.71 20 2.47 6.9 248 113 IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports. 75 70 IDB 65 37.5 0.78 20 2.62 7.4 280 126 36.4 0.74 21 2.60 7.3 278 125 33.6 0.72 21 2.54 7.1 269 121 63 37.1 0.64 16 2.60 7.3 278 125 36.0 0.61 17 2.58 7.2 275 124 33.3 0.59 17 2.52 7.1 267 120 75 40.6 0.59 16 2.70 7.6 296 138 39.4 0.56 17 2.68 7.5 293 136 36.4 0.54 17 2.62 7.3 284 132 67 40.7 0.44 12 2.68 7.5 293 136 39.5 0.42 13 2.66 7.5 290 135 36.4 0.41 13 2.59 7.3 282 131 43.5 0.38 11 2.78 7.8 309 147 42.3 0.36 12 2.76 7.8 306 145 39.0 0.35 12 2.70 7.6 297 141 71 35.5 0.90 22 2.72 7.8 296 123 34.5 0.85 23 2.70 7.7 293 122 31.8 0.82 23 2.64 7.5 285 118 59 34.9 0.79 19 2.70 7.7 293 122 33.9 0.75 20 2.68 7.6 291 121 31.3 0.72 20 2.61 7.4 282 117 36.6 0.80 20 2.78 7.9 319 131 35.5 0.76 21 2.76 7.9 316 130 32.8 0.74 21 2.69 7.7 306 126 42.5 0.39 11 2.96 8.5 351 152 41.3 0.37 12 2.93 8.4 348 151 38.1 0.36 12 2.86 8.2 337 146 34.7 0.92 22 2.86 8.3 338 129 33.7 0.88 23 2.83 8.2 334 128 31.1 0.85 23 2.77 8.0 324 124 35.7 0.83 20 2.92 8.4 363 138 34.7 0.79 21 2.90 8.4 360 136 32.0 0.76 21 2.83 8.2 349 132 38.6 0.63 16 3.01 8.7 384 150 37.5 0.60 17 2.99 8.6 380 149 34.6 0.58 17 2.91 8.4 368 144 Shaded area reflects ACCA (TVA) conditions 39.6 0.61 16 2.86 8.2 337 143 38.5 0.58 17 2.84 8.1 334 142 35.5 0.56 17 2.77 7.9 324 137 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 36.2 39.7 34.1 35.3 38.7 0.66 0.46 0.81 0.68 0.47 16 12 19 16 12 2.76 2.84 2.83 2.89 2.99 7.9 8.1 8.2 8.4 8.6 316 333 334 360 380 130 142 128 136 149 35.2 38.5 33.1 34.3 37.6 0.63 0.43 0.78 0.65 0.45 17 13 20 17 13 2.73 2.82 2.81 2.87 2.96 7.8 8.0 8.1 8.3 8.6 313 330 331 356 376 128 140 127 135 147 30.6 31.7 34.7 32.5 35.6 0.61 0.42 0.75 0.62 0.43 17 13 20 17 13 2.67 2.75 2.74 2.80 2.89 7.6 7.8 7.9 8.1 8.3 303 320 321 345 365 125 136 123 131 143 41.5 0.40 11 3.11 9.0 400 160 40.3 0.38 12 3.08 8.9 396 158 37.2 0.37 12 3.01 8.7 384 154 71 32.9 0.96 22 2.97 8.7 380 136 32.0 0.91 22 2.95 8.7 376 134 29.5 0.88 23 2.88 8.4 365 130 59 32.4 0.84 19 2.95 8.7 376 134 31.4 0.80 19 2.93 8.6 372 133 29.0 0.78 20 2.86 8.4 361 129 36.7 0.65 16 3.13 9.2 432 157 35.6 0.62 17 3.11 9.1 427 156 32.9 0.60 17 3.03 8.9 415 151 67 36.8 0.49 12 3.11 9.1 427 156 35.7 0.47 13 3.08 9.1 423 154 33.0 0.45 13 3.01 8.8 410 150 39.4 0.42 11 3.24 9.5 450 168 38.3 0.40 12 3.21 9.5 446 166 35.3 0.38 12 3.13 9.2 432 161 71 30.5 0.97 20 3.07 9.2 420 140 29.6 0.92 21 3.05 9.1 416 139 27.3 0.89 21 2.98 8.9 403 135 59 30.0 0.85 17 3.05 9.1 415 139 29.1 0.81 18 3.02 9.1 411 137 26.9 0.78 18 2.95 8.8 399 133 31.4 0.87 19 3.14 9.4 452 149 30.5 0.83 19 3.12 9.4 447 148 28.2 0.80 20 3.04 9.1 434 143 63 31.1 0.71 15 3.11 9.4 447 148 30.2 0.68 16 3.09 9.3 443 146 27.9 0.65 16 3.01 9.0 429 142 34.0 0.65 15 3.24 9.7 477 163 33.0 0.62 16 3.22 9.6 472 161 30.5 0.60 16 3.14 9.4 458 156 67 34.1 0.49 11 3.22 9.6 472 161 33.1 0.47 12 3.19 9.6 467 160 30.5 0.45 12 3.11 9.3 453 155 115 36.5 0.42 10 3.35 10.1 497 173 35.4 0.40 11 3.32 10.0 492 172 32.7 0.39 11 3.24 9.7 478 167 71 - kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 33.9 0.86 20 3.04 8.9 409 144 32.9 0.82 21 3.01 8.9 405 143 30.4 0.79 21 2.94 8.6 393 139 63 33.6 0.70 16 3.01 8.9 405 143 32.6 0.67 17 2.99 8.8 401 141 30.1 0.65 17 2.92 8.6 389 137 105 Expanded Cooling Data — 3 Tons 7 8 www.daikinac.com 59 37.9 0.92 24 2.41 6.8 235 113 36.8 0.88 25 2.39 6.7 232 112 34.0 0.85 25 2.34 6.6 225 109 38.6 0.97 25 2.43 6.8 237 114 37.5 0.92 27 2.41 6.8 235 113 34.6 0.89 27 2.35 6.6 228 110 Airflow MBh S/T Delta T 1350 KW AMPS HI PR LO PR MBh S/T Delta T 1200 KW AMPS HI PR LO PR MBh S/T Delta T 1050 KW AMPS HI PR LO PR MBh S/T Delta T 1350 KW AMPS HI PR LO PR MBh S/T Delta T 1200 KW AMPS HI PR LO PR MBh S/T Delta T 1050 KW AMPS HI PR LO PR 39.3 0.93 25 2.48 7.0 255 122 38.2 0.89 26 2.46 6.9 252 121 35.3 0.86 27 2.40 6.7 245 117 63 38.8 0.87 23 2.46 6.9 252 121 37.6 0.83 24 2.44 6.9 250 119 34.7 0.80 24 2.38 6.7 242 116 41.2 0.84 24 2.55 7.2 269 133 40.0 0.80 25 2.53 7.1 267 132 36.9 0.78 25 2.47 6.9 259 128 67 41.4 0.71 20 2.53 7.1 267 132 40.2 0.67 21 2.51 7.1 264 130 37.1 0.65 21 2.45 6.9 256 126 44.0 0.68 20 2.63 7.4 281 142 42.7 0.65 21 2.61 7.4 278 140 39.4 0.63 22 2.55 7.2 270 136 71 44.3 0.53 16 2.61 7.4 278 140 43.0 0.50 17 2.59 7.3 275 139 39.7 0.48 17 2.53 7.1 267 135 37.7 1.00 26 2.61 7.3 266 121 36.6 0.96 27 2.59 7.3 263 120 33.8 0.92 27 2.53 7.1 255 116 59 37.1 0.96 24 2.59 7.3 263 120 36.0 0.91 25 2.57 7.2 261 119 33.2 0.88 26 2.51 7.0 253 115 IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports. 85 80 IDB 65 38.4 0.97 25 2.66 7.5 286 129 37.3 0.92 26 2.64 7.4 283 127 34.4 0.89 27 2.58 7.2 275 124 63 37.9 0.90 23 2.64 7.4 283 127 36.8 0.86 24 2.62 7.4 281 126 33.9 0.83 25 2.56 7.2 272 122 75 40.3 0.87 24 2.74 7.7 302 140 39.1 0.83 25 2.72 7.6 299 139 36.1 0.80 25 2.66 7.5 290 135 67 40.5 0.73 20 2.72 7.6 299 139 39.3 0.70 21 2.70 7.6 296 138 36.3 0.67 21 2.64 7.4 287 134 42.9 0.71 21 2.83 8.0 315 150 41.7 0.68 22 2.81 7.9 312 148 38.5 0.65 22 2.74 7.7 303 144 71 43.2 0.55 16 2.81 7.9 312 148 42.0 0.52 17 2.78 7.8 309 147 38.8 0.50 17 2.72 7.6 300 142 36.8 1.00 25 2.76 7.9 302 126 35.7 0.98 27 2.74 7.8 299 124 33.0 0.95 27 2.68 7.6 290 121 59 36.2 1.00 25 2.74 7.8 299 124 35.1 0.94 25 2.72 7.8 296 123 32.4 0.90 26 2.66 7.6 288 120 37.5 0.99 25 2.82 8.1 325 134 36.4 0.95 26 2.80 8.0 322 132 33.6 0.91 27 2.73 7.8 313 128 41.9 0.73 21 3.00 8.6 358 155 40.7 0.69 22 2.98 8.5 355 154 37.6 0.67 22 2.91 8.3 344 149 35.9 1.00 24 2.90 8.4 344 132 34.9 1.00 27 2.88 8.3 341 131 32.2 0.98 28 2.81 8.1 331 127 36.6 1.00 25 2.97 8.6 371 140 35.5 0.98 27 2.94 8.5 367 139 32.8 0.94 27 2.87 8.3 356 135 Shaded area reflects AHRI conditions 39.3 0.90 24 2.91 8.3 344 146 38.1 0.86 25 2.89 8.3 340 145 35.2 0.82 25 2.82 8.0 330 140 38.3 0.93 24 3.06 8.8 391 153 37.2 0.88 25 3.04 8.8 388 152 34.4 0.85 26 2.96 8.5 376 147 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 37.0 39.5 42.2 35.3 36.1 38.5 0.92 0.75 0.56 1.00 0.95 0.77 23 20 16 24 23 20 2.80 2.89 2.98 2.88 2.94 3.04 8.0 8.3 8.5 8.3 8.5 8.8 322 340 355 341 367 388 132 145 154 131 139 152 35.9 38.3 41.0 34.3 35.0 37.4 0.88 0.71 0.53 0.97 0.91 0.74 24 21 17 25 24 21 2.78 2.86 2.96 2.86 2.92 3.01 7.9 8.2 8.5 8.3 8.4 8.7 319 337 351 338 363 384 131 143 152 129 138 150 33.1 35.4 37.8 31.6 32.3 34.5 0.85 0.69 0.52 0.93 0.87 0.71 25 21 17 26 25 22 2.71 2.80 2.89 2.79 2.85 2.94 7.7 8.0 8.2 8.0 8.2 8.5 309 327 341 328 352 372 127 139 148 126 134 146 40.9 0.75 21 3.16 9.2 408 163 39.7 0.72 22 3.13 9.1 404 162 36.6 0.69 22 3.06 8.8 392 157 71 41.2 0.58 16 3.13 9.1 404 162 40.0 0.55 17 3.11 9.0 400 160 36.9 0.53 17 3.03 8.8 388 155 34.1 1.00 23 3.02 8.9 387 138 33.1 1.00 25 3.00 8.8 384 137 30.6 1.00 27 2.93 8.6 372 133 59 33.5 1.00 23 3.00 8.8 384 137 32.5 1.00 25 2.97 8.7 380 136 30.0 0.97 25 2.90 8.5 368 132 36.4 0.96 24 3.19 9.4 440 161 35.4 0.92 25 3.16 9.3 436 159 32.6 0.88 25 3.08 9.1 423 154 67 36.6 0.80 20 3.16 9.3 436 159 35.5 0.77 21 3.14 9.2 432 158 32.8 0.74 21 3.06 9.0 419 153 38.9 0.78 21 3.29 9.7 459 171 37.7 0.74 21 3.26 9.6 455 169 34.8 0.72 22 3.18 9.4 441 164 71 39.1 0.60 16 3.26 9.6 455 169 38.0 0.57 17 3.24 9.5 450 168 35.1 0.55 17 3.16 9.3 437 163 31.6 1.00 22 3.12 9.4 428 143 30.7 1.00 24 3.10 9.3 424 142 28.3 1.00 25 3.02 9.1 411 137 59 31.1 1.00 21 3.10 9.3 424 142 30.2 1.00 23 3.07 9.2 420 140 27.8 0.98 24 3.00 9.0 407 136 32.2 1.00 22 3.19 9.6 461 152 31.3 1.00 24 3.17 9.5 456 151 28.9 0.99 25 3.09 9.3 442 146 63 31.7 1.00 22 3.17 9.5 456 151 30.8 0.95 22 3.14 9.4 452 149 28.4 0.92 23 3.06 9.2 438 145 33.7 0.97 22 3.30 9.9 487 166 32.8 0.92 23 3.27 9.8 482 165 30.2 0.89 24 3.19 9.6 467 160 67 33.9 0.81 19 3.27 9.8 482 165 32.9 0.77 19 3.24 9.7 477 163 30.4 0.74 20 3.16 9.5 463 158 115 36.0 0.79 19 3.40 10.3 507 177 34.9 0.75 20 3.38 10.2 502 175 32.3 0.72 20 3.29 9.9 487 170 71 36.2 0.61 15 3.38 10.2 502 175 35.2 0.58 16 3.35 10.1 497 174 32.5 0.56 16 3.27 9.8 483 168 kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 34.8 1.00 24 3.09 9.1 417 147 33.8 1.00 26 3.06 9.0 413 146 31.2 0.98 27 2.99 8.8 400 141 63 34.3 1.00 23 3.06 9.0 413 146 33.3 0.94 24 3.04 8.9 409 144 30.7 0.91 24 2.96 8.7 397 140 105 Expanded Cooling Data — 3 Tons (cont.) SS-DSH3 SS-DSH3 www.daikinac.com 59 46.3 0.77 18 3.09 8.0 241 112 44.9 0.73 19 3.07 7.9 239 111 41.5 0.71 19 3.00 7.7 232 107 47.1 0.87 21 3.12 8.1 244 113 45.7 0.83 22 3.09 8.0 241 112 42.2 0.80 22 3.02 7.8 234 108 Airflow MBh S/T Delta T 1800 KW AMPS HI PR LO PR MBh S/T Delta T 1600 KW AMPS HI PR LO PR MBh S/T Delta T 1400 KW AMPS HI PR LO PR MBh S/T Delta T 1800 KW AMPS HI PR LO PR MBh S/T Delta T 1600 KW AMPS HI PR LO PR MBh S/T Delta T 1400 KW AMPS HI PR LO PR 48.5 0.78 19 3.18 8.2 262 120 47.0 0.75 20 3.15 8.2 260 119 43.4 0.72 21 3.08 8.0 252 115 63 48.0 0.64 16 3.15 8.2 260 119 46.6 0.61 16 3.13 8.1 257 118 43.0 0.59 17 3.06 7.9 249 114 52.4 0.59 16 3.27 8.5 277 131 50.9 0.56 17 3.25 8.4 274 130 47.0 0.54 17 3.17 8.2 266 126 67 52.5 0.45 12 3.25 8.4 274 130 51.0 0.42 12 3.22 8.3 272 128 47.1 0.41 13 3.15 8.1 263 125 56.3 0.38 11 3.37 8.8 289 140 54.6 0.36 11 3.35 8.7 286 138 50.4 0.35 12 3.27 8.5 277 134 71 46.0 0.91 21 3.34 8.7 274 119 44.6 0.86 22 3.32 8.6 271 118 41.2 0.83 23 3.24 8.4 263 115 59 45.2 0.80 18 3.32 8.6 271 118 43.9 0.76 19 3.29 8.5 268 117 40.5 0.73 20 3.22 8.3 260 113 IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports. 75 70 IDB 65 47.3 0.81 20 3.41 8.9 294 127 45.9 0.77 20 3.38 8.8 291 126 42.4 0.75 21 3.31 8.6 283 122 63 46.8 0.67 16 3.38 8.8 291 126 45.5 0.64 17 3.36 8.7 289 124 42.0 0.61 17 3.28 8.5 280 121 75 51.2 0.61 16 3.51 9.1 311 138 49.7 0.59 17 3.49 9.0 308 137 45.9 0.56 17 3.41 8.8 299 133 67 51.3 0.46 12 3.49 9.0 308 137 49.8 0.44 13 3.46 9.0 305 136 46.0 0.42 13 3.38 8.7 296 132 55.0 0.39 11 3.62 9.4 324 147 53.4 0.38 12 3.60 9.4 321 146 49.3 0.36 12 3.51 9.1 311 142 71 44.9 0.93 21 3.54 9.4 311 124 43.6 0.89 22 3.51 9.3 308 123 40.2 0.85 23 3.43 9.0 299 119 59 44.1 0.82 18 3.51 9.3 308 123 42.8 0.78 19 3.49 9.2 305 121 39.5 0.75 20 3.41 9.0 296 118 46.2 0.83 20 3.62 9.6 335 132 44.9 0.79 20 3.59 9.5 331 131 41.4 0.76 21 3.50 9.2 322 127 53.7 0.40 11 3.84 10.2 369 153 52.1 0.39 12 3.81 10.1 365 152 48.1 0.37 12 3.72 9.9 354 147 43.8 0.96 21 3.72 10.0 354 130 42.5 0.91 22 3.69 9.9 351 129 39.2 0.88 23 3.60 9.6 340 125 45.1 0.86 20 3.80 10.2 381 138 43.8 0.82 21 3.77 10.1 378 137 40.4 0.79 21 3.68 9.8 366 133 48.8 0.65 16 3.91 10.5 403 151 47.4 0.62 17 3.88 10.4 399 150 43.7 0.60 17 3.79 10.1 387 145 Shaded area reflects ACCA (TVA) conditions 50.0 0.63 16 3.73 9.9 354 144 48.5 0.60 17 3.70 9.8 350 143 44.8 0.58 17 3.61 9.5 340 138 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 45.7 50.1 43.0 44.6 48.9 0.68 0.47 0.84 0.70 0.49 16 12 19 16 12 3.59 3.70 3.69 3.77 3.88 9.5 9.8 9.9 10.1 10.4 331 350 351 377 399 131 142 129 137 150 44.4 48.6 41.8 43.3 47.5 0.65 0.45 0.80 0.67 0.47 17 13 19 17 13 3.56 3.67 3.66 3.74 3.85 9.4 9.7 9.8 10.0 10.3 328 346 347 374 395 129 141 128 136 148 41.0 44.9 38.6 40.0 43.8 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 3.48 3.58 3.57 3.65 3.76 9.2 9.4 9.5 9.7 10.1 318 336 337 363 383 125 137 124 132 144 52.4 0.42 11 4.04 10.9 420 161 50.8 0.40 12 4.01 10.8 416 159 46.9 0.38 12 3.91 10.5 403 155 71 41.6 1.00 21 3.87 10.6 399 136 40.4 0.95 22 3.84 10.5 395 135 37.3 0.92 22 3.75 10.2 383 131 59 40.9 0.88 18 3.84 10.5 395 135 39.7 0.84 19 3.81 10.4 391 134 36.6 0.81 19 3.72 10.1 379 130 46.3 0.67 16 4.07 11.1 453 158 45.0 0.64 17 4.04 11.0 449 157 41.5 0.62 17 3.94 10.8 435 152 67 46.4 0.51 12 4.04 11.0 448 157 45.1 0.48 13 4.01 10.9 444 155 41.6 0.47 13 3.91 10.7 431 151 49.7 0.43 11 4.21 11.5 472 169 48.3 0.41 11 4.17 11.4 468 167 44.6 0.40 12 4.07 11.1 454 162 71 38.5 1.00 20 4.00 11.1 440 141 37.4 0.96 21 3.96 11.0 436 140 34.5 0.92 21 3.87 10.8 423 136 59 37.9 0.88 17 3.96 11.0 436 140 36.8 0.84 18 3.93 10.9 432 138 33.9 0.81 18 3.84 10.7 419 134 39.7 0.90 18 4.08 11.4 474 150 38.5 0.86 19 4.05 11.3 469 149 35.5 0.83 19 3.95 11.0 455 144 63 39.3 0.74 15 4.05 11.3 469 149 38.1 0.70 15 4.02 11.2 465 147 35.2 0.68 16 3.92 10.9 451 143 42.9 0.68 15 4.21 11.8 501 164 41.7 0.65 16 4.18 11.7 496 162 38.5 0.63 16 4.08 11.4 481 157 67 43.0 0.51 11 4.18 11.7 495 162 41.8 0.49 12 4.14 11.6 491 161 38.5 0.47 12 4.04 11.3 476 156 115 46.1 0.44 10 4.35 12.2 522 175 44.7 0.42 11 4.31 12.1 517 173 41.3 0.40 11 4.21 11.8 501 168 71 - kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 42.8 0.89 19 3.95 10.8 429 145 41.6 0.85 20 3.92 10.7 425 144 38.4 0.82 21 3.82 10.4 412 139 63 42.4 0.73 16 3.92 10.7 425 144 41.2 0.70 16 3.89 10.6 420 142 38.0 0.67 17 3.79 10.3 408 138 105 Expanded Cooling Data — 4 Tons 9 10 www.daikinac.com 59 47.9 0.96 23 3.14 8.1 246 114 46.5 0.91 24 3.12 8.1 244 113 42.9 0.88 25 3.05 7.9 236 109 48.7 1.00 25 3.16 8.2 249 115 47.3 0.96 26 3.14 8.1 246 114 43.7 0.92 27 3.07 7.9 239 111 Airflow MBh S/T Delta T 1800 KW AMPS HI PR LO PR MBh S/T Delta T 1600 KW AMPS HI PR LO PR MBh S/T Delta T 1400 KW AMPS HI PR LO PR MBh S/T Delta T 1800 KW AMPS HI PR LO PR MBh S/T Delta T 1600 KW AMPS HI PR LO PR MBh S/T Delta T 1400 KW AMPS HI PR LO PR 49.7 0.97 25 3.23 8.4 268 122 48.2 0.93 26 3.20 8.3 265 121 44.5 0.89 26 3.13 8.1 257 118 63 48.9 0.90 22 3.20 8.3 265 121 47.5 0.86 23 3.18 8.2 262 120 43.9 0.83 24 3.11 8.0 255 116 52.0 0.88 23 3.32 8.6 283 134 50.5 0.84 24 3.30 8.6 280 132 46.6 0.81 25 3.22 8.3 271 128 67 52.3 0.73 20 3.30 8.6 280 132 50.8 0.70 20 3.27 8.5 277 131 46.9 0.67 21 3.20 8.3 269 127 55.5 0.71 20 3.42 8.9 295 142 53.9 0.68 21 3.40 8.9 292 141 49.7 0.65 21 3.32 8.6 283 137 71 55.9 0.55 16 3.40 8.9 292 141 54.3 0.52 16 3.37 8.8 289 140 50.1 0.50 17 3.30 8.6 280 135 47.6 1.00 24 3.39 8.8 279 122 46.2 0.99 26 3.37 8.7 276 120 42.7 0.96 27 3.29 8.5 268 117 59 46.8 1.00 24 3.37 8.7 276 120 45.4 0.95 25 3.34 8.7 274 119 41.9 0.91 25 3.27 8.4 265 116 IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports. 85 80 IDB 65 48.5 1.00 25 3.46 9.0 300 129 47.1 0.96 26 3.44 8.9 297 128 43.5 0.92 26 3.36 8.7 288 124 63 47.8 0.93 23 3.44 8.9 297 128 46.4 0.89 24 3.41 8.9 294 127 42.8 0.86 24 3.33 8.6 286 123 75 50.8 0.91 24 3.57 9.3 317 141 49.3 0.87 25 3.54 9.2 314 140 45.5 0.83 25 3.46 9.0 305 136 67 51.1 0.76 20 3.54 9.2 314 140 49.6 0.72 21 3.51 9.1 311 138 45.8 0.70 21 3.43 8.9 302 134 54.2 0.74 20 3.68 9.6 331 150 52.6 0.70 21 3.65 9.5 327 149 48.6 0.68 22 3.57 9.3 318 145 71 54.6 0.57 16 3.65 9.5 327 149 53.0 0.54 16 3.62 9.4 324 148 48.9 0.52 17 3.54 9.2 315 143 46.5 1.00 24 3.60 9.5 317 126 45.1 1.00 26 3.57 9.4 314 125 41.6 0.98 27 3.49 9.2 305 121 59 45.7 1.00 23 3.57 9.4 314 125 44.3 0.97 25 3.54 9.4 311 124 40.9 0.94 25 3.46 9.1 302 120 47.4 1.00 24 3.67 9.7 342 135 46.0 0.98 26 3.64 9.6 338 133 42.4 0.95 26 3.56 9.4 328 129 52.9 0.76 20 3.91 10.4 376 156 51.4 0.72 21 3.88 10.3 372 155 47.4 0.69 22 3.78 10.0 361 150 45.3 1.00 23 3.78 10.1 361 133 44.0 1.00 25 3.75 10.0 358 131 40.6 1.00 27 3.66 9.8 347 128 46.2 1.00 24 3.86 10.4 389 141 44.9 1.00 26 3.83 10.3 385 140 41.4 0.98 27 3.73 10.0 374 136 Shaded area reflects AHRI conditions 49.6 0.93 24 3.79 10.0 361 147 48.2 0.89 25 3.76 9.9 357 145 44.5 0.86 25 3.67 9.7 346 141 48.4 0.96 24 3.98 10.7 411 154 47.0 0.92 25 3.95 10.6 407 153 43.4 0.88 25 3.85 10.3 395 148 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.7 49.9 53.3 44.6 45.5 48.6 0.96 0.78 0.58 1.00 1.00 0.80 23 20 16 23 23 20 3.64 3.76 3.88 3.75 3.83 3.95 9.6 9.9 10.3 10.0 10.3 10.6 338 357 372 358 385 407 133 145 155 131 140 153 45.3 48.4 51.7 43.3 44.2 47.2 0.91 0.74 0.55 1.00 0.94 0.77 24 21 16 25 24 21 3.62 3.73 3.84 3.72 3.80 3.92 9.6 9.9 10.2 10.0 10.2 10.5 335 354 369 354 381 403 132 144 153 130 138 151 41.8 44.7 47.8 39.9 40.8 43.6 0.88 0.72 0.53 0.97 0.91 0.74 24 21 17 25 24 21 3.53 3.64 3.75 3.63 3.71 3.82 9.3 9.6 9.9 9.7 9.9 10.2 325 343 358 344 370 391 128 140 149 126 134 147 51.6 0.78 21 4.11 11.1 428 164 50.1 0.74 21 4.07 11.0 424 163 46.3 0.72 22 3.97 10.7 411 158 71 52.0 0.60 16 4.07 11.0 424 163 50.5 0.57 17 4.04 10.9 420 161 46.6 0.55 17 3.94 10.6 407 156 43.1 1.00 22 3.93 10.7 407 139 41.8 1.00 24 3.90 10.6 403 138 38.6 1.00 25 3.80 10.4 391 134 59 42.3 1.00 22 3.90 10.6 403 138 41.1 1.00 24 3.87 10.6 399 136 37.9 1.00 25 3.77 10.3 387 132 46.0 1.00 23 4.14 11.3 462 162 44.6 0.95 24 4.11 11.2 458 160 41.2 0.92 25 4.01 10.9 444 155 67 46.2 0.83 20 4.11 11.2 458 160 44.9 0.80 20 4.07 11.1 453 158 41.4 0.77 21 3.98 10.8 439 154 49.1 0.81 20 4.27 11.7 482 172 47.6 0.77 21 4.24 11.6 477 170 44.0 0.74 21 4.14 11.3 463 165 71 49.4 0.62 16 4.24 11.6 477 170 48.0 0.59 16 4.21 11.5 473 169 44.3 0.57 17 4.10 11.2 458 164 39.9 1.00 20 4.06 11.3 449 144 38.7 1.00 22 4.03 11.2 445 143 35.7 1.00 23 3.93 10.9 432 138 59 39.2 1.00 20 4.03 11.2 445 143 38.1 1.00 22 4.00 11.1 440 141 35.1 1.01 23 3.90 10.9 427 137 40.7 1.00 21 4.15 11.6 484 153 39.5 1.00 23 4.12 11.5 479 152 36.4 1.00 24 4.02 11.2 464 147 63 40.1 1.00 20 4.12 11.5 479 152 38.9 0.98 22 4.08 11.4 474 150 35.9 0.95 22 3.98 11.1 460 146 42.6 1.00 22 4.28 12.0 511 167 41.3 0.96 23 4.25 11.9 506 166 38.2 0.92 23 4.14 11.6 490 161 67 42.8 0.84 18 4.25 11.9 506 166 41.6 0.80 19 4.21 11.8 501 164 38.4 0.77 19 4.11 11.5 486 159 115 45.4 0.82 19 4.42 12.4 533 178 44.1 0.78 20 4.39 12.3 527 176 40.7 0.75 20 4.28 12.0 511 171 71 45.8 0.63 15 4.39 12.3 527 176 44.4 0.60 15 4.35 12.2 522 175 41.0 0.58 16 4.24 11.9 506 169 kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 43.9 1.00 22 4.01 11.0 438 148 42.6 1.00 24 3.98 10.9 433 147 39.3 1.00 26 3.89 10.6 420 142 63 43.3 1.00 22 3.98 10.9 433 147 42.0 0.98 24 3.95 10.8 429 145 38.8 0.94 24 3.85 10.5 416 141 105 Expanded Cooling Data — 4 Tons (cont.) SS-DSH3 SS-DSH3 www.daikinac.com 59 59.2 0.75 18 3.97 10.3 238 112 57.4 0.72 19 3.94 10.2 236 111 53.0 0.69 19 3.85 9.9 228 107 60.2 0.85 21 4.00 10.3 240 113 58.4 0.82 22 3.97 10.3 238 112 53.9 0.79 22 3.88 10.0 231 108 Airflow MBh S/T Delta T 2250 KW AMPS HI PR LO PR MBh S/T Delta T 2000 KW AMPS HI PR LO PR MBh S/T Delta T 1750 KW AMPS HI PR LO PR MBh S/T Delta T 2250 KW AMPS HI PR LO PR MBh S/T Delta T 2000 KW AMPS HI PR LO PR MBh S/T Delta T 1750 KW AMPS HI PR LO PR 61.9 0.76 19 4.08 10.6 259 120 60.1 0.73 20 4.05 10.5 256 119 55.5 0.70 21 3.96 10.2 248 115 63 61.3 0.63 16 4.05 10.5 256 119 59.5 0.60 16 4.02 10.4 253 118 54.9 0.58 17 3.93 10.1 246 114 67.0 0.58 16 4.20 10.9 273 131 65.1 0.55 17 4.17 10.8 270 130 60.1 0.53 17 4.07 10.5 262 126 67 67.2 0.44 12 4.17 10.8 270 130 65.2 0.42 12 4.14 10.7 268 128 60.2 0.40 13 4.04 10.4 260 125 72.0 0.37 11 4.33 11.3 285 140 69.9 0.36 11 4.30 11.2 282 138 64.5 0.34 12 4.20 10.9 274 134 71 58.8 0.89 21 4.29 11.1 270 119 57.0 0.84 22 4.26 11.0 267 118 52.7 0.81 23 4.16 10.7 259 115 59 57.8 0.78 18 4.26 11.0 267 118 56.1 0.74 19 4.22 10.9 264 117 51.8 0.72 19 4.13 10.7 256 113 IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports. 75 70 IDB 65 60.5 0.79 20 4.38 11.4 290 127 58.7 0.76 20 4.34 11.3 287 126 54.2 0.73 21 4.24 11.0 279 122 63 59.9 0.65 16 4.34 11.3 287 126 58.1 0.62 17 4.31 11.2 284 124 53.7 0.60 17 4.21 10.9 276 121 75 65.5 0.60 16 4.51 11.7 306 138 63.6 0.57 17 4.48 11.6 303 137 58.7 0.55 17 4.37 11.3 294 133 67 65.6 0.45 12 4.48 11.6 303 137 63.7 0.43 13 4.44 11.5 300 136 58.8 0.41 13 4.34 11.2 291 132 70.3 0.39 11 4.65 12.1 320 147 68.2 0.37 12 4.62 12.0 316 146 63.0 0.35 12 4.51 11.7 307 142 71 57.4 0.91 21 4.55 12.0 307 124 55.7 0.87 22 4.51 11.9 304 123 51.4 0.84 23 4.41 11.6 295 119 59 56.4 0.80 18 4.51 11.9 304 123 54.8 0.76 19 4.48 11.8 301 121 50.5 0.74 20 4.37 11.5 292 118 59.1 0.81 20 4.64 12.3 330 132 57.3 0.78 20 4.61 12.2 327 131 52.9 0.75 21 4.50 11.9 317 127 68.6 0.40 11 4.94 13.1 364 153 66.6 0.38 12 4.90 13.0 360 152 61.5 0.36 12 4.78 12.7 349 147 56.0 0.94 21 4.77 12.8 349 130 54.3 0.89 22 4.74 12.7 346 129 50.1 0.86 23 4.62 12.4 335 125 57.6 0.84 20 4.87 13.1 376 138 55.9 0.80 21 4.84 13.0 372 137 51.6 0.77 21 4.72 12.6 361 133 62.4 0.63 16 5.03 13.5 397 151 60.6 0.61 17 4.99 13.4 393 150 55.9 0.58 17 4.87 13.0 381 145 Shaded area reflects ACCA (TVA) conditions 63.9 0.62 16 4.79 12.7 349 144 62.1 0.59 17 4.75 12.6 345 143 57.3 0.57 17 4.64 12.2 335 138 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 58.5 64.1 55.0 57.0 62.5 0.67 0.46 0.83 0.69 0.48 16 12 19 16 12 4.60 4.75 4.74 4.84 4.99 12.2 12.6 12.7 13.0 13.4 327 345 346 372 393 131 142 129 137 150 56.8 62.2 53.4 55.4 60.7 0.64 0.44 0.79 0.66 0.46 17 13 19 17 13 4.57 4.71 4.70 4.80 4.95 12.1 12.5 12.6 12.9 13.3 323 342 342 368 389 129 141 128 136 148 52.4 57.4 49.3 51.1 56.0 0.61 0.43 0.76 0.63 0.44 17 13 20 17 13 4.46 4.60 4.59 4.68 4.83 11.8 12.1 12.2 12.5 12.9 314 331 332 357 377 125 137 124 132 144 66.9 0.41 11 5.19 14.0 414 161 65.0 0.39 12 5.15 13.9 410 159 60.0 0.38 12 5.02 13.5 398 155 71 53.2 0.97 21 4.97 13.6 393 136 51.6 0.93 22 4.93 13.4 389 135 47.6 0.90 22 4.81 13.1 377 131 59 52.3 0.86 18 4.93 13.4 389 135 50.8 0.82 19 4.89 13.3 385 134 46.8 0.79 19 4.77 13.0 374 130 59.2 0.66 16 5.23 14.3 447 158 57.5 0.63 17 5.19 14.2 442 157 53.1 0.61 17 5.07 13.8 429 152 67 59.4 0.50 12 5.19 14.2 442 157 57.6 0.47 13 5.15 14.1 438 155 53.2 0.46 13 5.02 13.7 425 151 63.6 0.42 11 5.40 14.8 466 169 61.7 0.40 11 5.36 14.7 461 167 57.0 0.39 12 5.23 14.3 447 162 71 49.2 0.98 20 5.13 14.3 434 141 47.8 0.94 21 5.09 14.2 430 140 44.1 0.90 21 4.97 13.8 417 136 59 48.4 0.86 17 5.09 14.2 430 140 47.0 0.82 18 5.05 14.1 426 138 43.4 0.79 18 4.93 13.7 413 134 50.7 0.88 18 5.24 14.7 467 150 49.2 0.84 19 5.20 14.5 463 149 45.4 0.81 19 5.07 14.2 449 144 63 50.2 0.72 15 5.20 14.5 463 149 48.7 0.69 15 5.16 14.4 458 147 45.0 0.66 16 5.03 14.0 444 143 54.9 0.66 15 5.41 15.1 493 164 53.3 0.63 16 5.37 15.0 489 162 49.2 0.61 16 5.24 14.6 474 157 67 55.0 0.50 11 5.37 15.0 488 162 53.4 0.48 12 5.32 14.9 484 161 49.3 0.46 12 5.19 14.5 469 156 115 58.9 0.43 10 5.59 15.7 515 175 57.2 0.41 11 5.54 15.6 510 173 52.8 0.39 11 5.41 15.1 494 168 71 - kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 54.7 0.87 19 5.07 13.9 423 145 53.1 0.83 20 5.03 13.8 419 144 49.1 0.80 21 4.91 13.4 406 139 63 54.2 0.72 16 5.03 13.8 419 144 52.6 0.68 16 4.99 13.6 414 142 48.6 0.66 17 4.87 13.3 402 138 105 Expanded Cooling Data — 5 Tons 11 12 www.daikinac.com 59 61.2 0.94 23 4.03 10.4 243 114 59.4 0.89 24 4.00 10.3 240 113 54.9 0.86 25 3.91 10.1 233 109 62.3 0.98 25 4.06 10.5 245 115 60.5 0.94 26 4.03 10.4 243 114 55.8 0.90 27 3.94 10.2 235 111 Airflow MBh S/T Delta T 2250 KW AMPS HI PR LO PR MBh S/T Delta T 2000 KW AMPS HI PR LO PR MBh S/T Delta T 1750 KW AMPS HI PR LO PR MBh S/T Delta T 2250 KW AMPS HI PR LO PR MBh S/T Delta T 2000 KW AMPS HI PR LO PR MBh S/T Delta T 1750 KW AMPS HI PR LO PR 63.5 0.95 25 4.14 10.7 264 122 61.7 0.90 26 4.11 10.7 261 121 56.9 0.87 26 4.02 10.4 253 118 63 62.6 0.88 22 4.11 10.7 261 121 60.7 0.84 23 4.08 10.6 259 120 56.1 0.81 24 3.99 10.3 251 116 66.5 0.86 23 4.27 11.1 279 134 64.6 0.82 24 4.23 11.0 276 132 59.6 0.79 25 4.14 10.7 268 128 67 66.8 0.72 20 4.23 11.0 276 132 64.9 0.68 20 4.20 10.9 273 131 59.9 0.66 21 4.11 10.6 265 127 71.0 0.69 20 4.40 11.5 291 142 68.9 0.66 21 4.36 11.4 288 141 63.6 0.64 21 4.26 11.1 279 137 71 71.5 0.53 16 4.36 11.4 288 141 69.4 0.51 16 4.33 11.3 285 140 64.0 0.49 17 4.23 11.0 276 135 60.9 1.00 25 4.36 11.3 275 122 59.1 0.97 26 4.32 11.2 272 120 54.5 0.94 27 4.22 10.9 264 117 59 59.8 1.00 24 4.32 11.2 272 120 58.1 0.93 25 4.29 11.1 270 119 53.6 0.89 25 4.19 10.8 262 116 IDB = Entering Indoor Dry Bulb Temperature High & low pressures are measured at the liquid & suction service ports. 85 80 IDB 65 62.0 0.98 25 4.45 11.6 296 129 60.2 0.94 26 4.41 11.5 293 128 55.6 0.90 26 4.31 11.2 284 124 63 61.1 0.91 23 4.41 11.5 293 128 59.3 0.87 24 4.38 11.4 290 127 54.8 0.84 24 4.28 11.1 282 123 75 65.0 0.89 24 4.58 11.9 313 141 63.1 0.85 25 4.55 11.8 310 140 58.2 0.82 25 4.44 11.5 300 136 67 65.3 0.74 20 4.55 11.8 310 140 63.4 0.71 21 4.51 11.7 306 138 58.5 0.68 21 4.41 11.4 297 134 69.3 0.72 20 4.73 12.3 326 150 67.3 0.69 21 4.69 12.2 323 149 62.1 0.66 22 4.58 11.9 313 145 71 69.8 0.55 16 4.69 12.2 323 149 67.8 0.53 16 4.65 12.1 320 148 62.5 0.51 17 4.54 11.8 310 143 59.4 1.00 24 4.62 12.2 313 126 57.7 1.00 26 4.58 12.1 310 125 53.2 0.96 27 4.48 11.8 301 121 59 58.4 1.00 24 4.58 12.1 310 125 56.7 0.95 25 4.55 12.0 307 124 52.3 0.92 25 4.44 11.7 298 120 60.6 1.00 25 4.72 12.5 337 135 58.8 0.96 26 4.68 12.4 333 133 54.3 0.93 26 4.57 12.1 323 129 67.7 0.74 20 5.02 13.4 371 156 65.7 0.70 21 4.98 13.2 367 155 60.6 0.68 22 4.86 12.9 356 150 58.0 1.00 24 4.85 13.0 356 133 56.3 1.00 26 4.81 12.9 353 131 51.9 0.99 27 4.70 12.6 342 128 59.1 1.00 24 4.95 13.3 384 141 57.4 0.99 26 4.91 13.2 380 140 52.9 0.96 27 4.80 12.9 368 136 Shaded area reflects AHRI conditions 63.4 0.91 24 4.86 12.9 356 147 61.6 0.87 25 4.82 12.8 352 145 56.8 0.84 25 4.71 12.5 341 141 61.9 0.94 24 5.11 13.7 405 154 60.1 0.90 25 5.07 13.6 401 153 55.4 0.86 25 4.95 13.3 389 148 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 59.7 63.7 68.1 57.0 58.2 62.2 0.93 0.76 0.57 1.00 0.96 0.79 23 20 16 23 23 20 4.68 4.82 4.98 4.81 4.91 5.07 12.4 12.8 13.2 12.9 13.2 13.6 333 352 367 353 380 401 133 145 155 131 140 153 57.9 61.9 66.1 55.3 56.5 60.4 0.89 0.73 0.54 0.98 0.92 0.75 24 21 16 25 24 21 4.64 4.79 4.94 4.77 4.87 5.03 12.3 12.7 13.1 12.8 13.1 13.5 330 349 364 349 376 397 132 144 153 130 138 151 53.5 57.1 61.1 51.0 52.2 55.7 0.86 0.70 0.52 0.95 0.89 0.72 24 21 17 25 24 21 4.53 4.67 4.82 4.66 4.76 4.91 12.0 12.3 12.8 12.5 12.7 13.1 320 338 353 339 365 385 128 140 149 126 134 147 66.0 0.76 21 5.27 14.2 422 164 64.1 0.73 21 5.23 14.1 418 163 59.1 0.70 22 5.10 13.7 406 158 71 66.5 0.59 16 5.23 14.1 418 163 64.5 0.56 17 5.19 14.0 414 161 59.6 0.54 17 5.06 13.6 402 156 55.1 1.00 22 5.05 13.8 401 139 53.5 1.00 25 5.01 13.7 397 138 49.3 1.00 26 4.89 13.3 385 134 59 54.1 1.00 22 5.01 13.7 397 138 52.5 1.00 24 4.97 13.6 393 136 48.5 0.98 25 4.85 13.2 381 132 58.8 0.97 23 5.32 14.6 456 162 57.1 0.93 24 5.28 14.5 451 160 52.7 0.90 25 5.15 14.1 438 155 67 59.1 0.81 20 5.28 14.5 451 160 57.4 0.78 20 5.23 14.3 447 158 52.9 0.75 21 5.11 13.9 433 154 62.7 0.79 20 5.49 15.1 475 172 60.9 0.75 21 5.45 15.0 470 170 56.2 0.73 21 5.31 14.6 456 165 71 63.1 0.61 16 5.45 15.0 470 170 61.3 0.58 16 5.40 14.8 466 169 56.6 0.56 17 5.27 14.4 452 164 51.0 1.00 21 5.22 14.6 443 144 49.5 1.00 23 5.17 14.5 439 143 45.7 1.00 24 5.05 14.1 425 138 59 50.1 1.00 20 5.17 14.5 439 143 48.7 1.00 22 5.13 14.3 434 141 44.9 0.99 23 5.01 14.0 421 137 52.0 1.00 21 5.33 14.9 477 153 50.5 1.00 23 5.29 14.8 472 152 46.6 1.00 24 5.16 14.4 458 147 63 51.2 1.00 21 5.29 14.8 472 152 49.7 0.96 22 5.24 14.7 467 150 45.9 0.93 22 5.12 14.3 453 146 54.4 0.98 22 5.50 15.4 503 167 52.9 0.94 23 5.46 15.3 498 166 48.8 0.90 23 5.32 14.9 483 161 67 54.7 0.82 18 5.46 15.3 498 166 53.1 0.78 19 5.41 15.1 493 164 49.0 0.76 19 5.28 14.7 479 159 115 58.1 0.80 19 5.68 16.0 525 178 56.4 0.76 20 5.63 15.8 520 176 52.1 0.73 20 5.49 15.4 504 171 71 58.5 0.61 15 5.63 15.8 520 176 56.8 0.59 15 5.59 15.7 515 175 52.4 0.56 16 5.45 15.3 499 169 kW = Total system power Amps: Unit amps (comp.+ evaporator + condenser fan motors) 56.1 1.00 23 5.15 14.1 431 148 54.5 1.00 25 5.11 14.0 427 147 50.3 0.99 26 4.99 13.6 414 142 63 55.3 1.00 23 5.11 14.0 427 147 53.7 0.95 24 5.07 13.9 423 145 49.5 0.92 24 4.95 13.5 410 141 105 Expanded Cooling Data — 5 Tons (cont.) SS-DSH3 Airflow Data — 3 Tons Standard Belt Drive — Down Shot ESP (" W.C.) Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.1 --- --- --- --- --- --- --- --- 1358 0.32 1210 0.24 0.2 --- --- --- --- --- --- --- --- 1203 0.29 1044 0.23 0.3 --- --- --- --- --- --- 1209 0.34 1044 0.27 854 0.22 0.4 --- --- --- --- 1320 0.34 1050 0.31 836 0.24 665 0.20 0.5 --- --- 1317 0.37 1124 0.31 862 0.29 --- --- --- --- 0.6 --- --- 1154 0.34 930 0.28 675 0.25 --- --- --- --- 0.7 1270 0.41 991 0.31 685 0.25 --- --- --- --- --- --- 0.8 1091 0.37 807 0.28 --- --- --- --- --- --- --- --- 0.9 905 0.34 633 0.25 --- --- --- --- --- --- --- --- 1.0 660 0.29 --- --- --- --- --- --- --- --- --- --- High-Static Belt Drive — Down Shot ESP (" W.C.) Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.6 --- --- --- --- --- --- --- --- --- --- --- --- 0.7 --- --- --- --- --- --- --- --- --- --- --- --- 0.8 --- --- --- --- --- --- --- --- --- --- 1240 0.44 0.9 --- --- --- --- --- --- --- --- --- --- 1124 0.43 1.0 --- --- --- --- --- --- --- --- 1225 0.48 965 0.39 1.1 --- --- --- --- --- --- 1280 0.55 1063 0.44 804 0.37 1.2 --- --- --- --- --- --- 1143 0.52 867 0.40 --- --- 1.3 --- --- --- --- 1268 0.59 963 0.48 651 0.36 --- --- 1.4 --- --- 1347 0.69 1127 0.55 766 0.43 --- --- --- --- 1.5 --- --- 1211 0.65 986 0.52 --- --- --- --- --- --- 1.6 1290 0.73 1024 0.59 833 0.48 --- --- --- --- --- --- 1.7 1152 0.69 837 0.55 --- --- --- --- --- --- --- --- 1.8 1062 0.66 --- --- --- --- --- --- --- --- --- --- SS-DSH3 www.daikinac.com 13 Airflow Data — 3 Tons (cont.) Standard Belt Drive — Horizontal ESP (" W.C.) Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.1 --- --- --- --- --- --- --- --- --- --- 1375 0.28 0.2 --- --- --- --- --- --- --- --- 1367 0.33 1186 0.21 0.3 --- --- --- --- --- --- 1374 0.39 1186 0.31 971 --- 0.4 --- --- --- --- --- --- 1193 0.36 952 0.28 756 --- 0.5 --- --- --- --- 1277 0.36 980 0.34 718 0.26 --- --- 0.6 --- --- 1312 0.39 1056 0.33 767 0.31 --- --- --- --- 0.7 --- --- 1126 0.36 779 0.29 --- --- --- --- --- --- 0.8 1240 0.43 917 0.33 --- --- --- --- --- --- --- --- 0.9 1029 0.39 708 0.30 --- --- --- --- --- --- --- --- 1.0 749 0.34 --- --- --- --- --- --- --- --- --- --- High-Static Belt Drive — Horizontal ESP (" W.C.) 14 Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.6 --- --- --- --- --- --- --- --- --- --- --- --- 0.7 --- --- --- --- --- --- --- --- --- --- --- --- 0.8 --- --- --- --- --- --- --- --- --- --- 1459 0.51 0.9 --- --- --- --- --- --- --- --- --- --- 1322 0.50 1.0 --- --- --- --- --- --- --- --- 1392 0.55 1136 0.46 1.1 --- --- --- --- --- --- 1455 0.63 1208 0.51 947 0.43 1.2 --- --- --- --- --- --- 1299 0.60 985 0.46 738 0.40 1.3 --- --- --- --- 1409 0.65 1094 0.54 740 0.41 --- --- 1.4 --- --- 1480 0.76 1252 0.61 870 0.49 --- --- --- --- 1.5 --- --- 1331 0.71 1095 0.57 --- --- --- --- --- --- 1.6 1418 0.80 1126 0.65 925 0.53 --- --- --- --- --- --- 1.7 1266 0.75 920 0.60 --- --- --- --- --- --- --- --- 1.8 1168 0.73 --- --- --- --- --- --- --- --- --- --- www.daikinac.com SS-DSH3 Airflow Data — 3 Tons (cont.) Standard Direct Drive — Horizontal CFM Static Amps Watts RPM Standard Direct Drive — Down Shot Speed Tap CFM Static Amps Watts RPM 1280 0.1 1.54 360 755 1270 0.1 1.53 355 760 1215 0.2 1.5 345 800 1205 0.2 1.53 350 810 1145 0.3 1.46 335 830 1145 0.3 1.49 340 840 1080 0.4 1.42 325 870 1085 0.4 1.45 330 875 1005 0.5 1.37 310 895 1035 0.5 1.42 320 900 1485 0.1 1.98 460 840 1460 0.6 1.96 450 850 1410 0.2 1.92 440 870 1380 0.1 1.89 430 885 1335 0.3 1.86 425 900 1255 0.4 1.8 410 930 1170 0.5 1.75 400 1075 0.6 1.68 380 Low 1275 0.2 1.8 405 915 1175 0.3 1.73 400 950 950 1075 0.4 1.68 380 965 980 1005 0.5 1.63 370 1000 Med 945 0.7 1.6 360 1005 915 0.6 1.59 360 1015 1445 0.2 2.2 505 940 1445 0.7 2.2 500 950 1365 0.3 2.14 490 960 1340 0.3 2.13 480 975 1270 0.4 2.08 470 985 1275 0.4 2.07 465 1000 1180 0.5 2.02 460 1000 1175 0.5 2.02 455 1020 1050 0.6 1.92 435 1030 1040 0.6 1.92 430 1045 825 0.7 1.78 400 1055 830 0.7 1.78 395 1070 920 0.8 1.90 390 1067 922 0.8 1.90 386 1067 High Speed Tap Low Med High See Notes below Airflow Data — 4 Tons Standard Direct Drive — Horizontal CFM Static Amps Watts RPM Standard Direct Drive — Down Shot Speed Tap CFM Static Amps Watts RPM 1570 0.1 2.09 490 905 1548 0.1 2.03 480 930 1520 0.2 2.06 480 920 1500 0.2 2.00 470 945 1445 0.3 1.95 460 945 1425 0.3 1.89 450 970 1375 0.4 1.89 440 970 1353 0.4 1.83 430 995 Low 1295 0.5 1.81 425 995 1273 0.5 175 415 1020 1715 0.1 2.39 560 975 1660 0.1 2.31 540 1020 1655 0.2 2.32 545 985 1625 0.2 2.25 530 1035 1580 0.3 2.24 525 1005 1565 0.3 2.19 515 1040 1500 0.4 2.16 505 1020 1405 0.5 2.09 490 1035 Med 1485 0.4 2.12 505 1050 1405 0.5 2.12 500 1055 1305 0.6 2.00 465 1050 1285 0.6 1.98 465 1060 1200 0.7 1.92 440 1065 1200 0.7 1.93 440 1070 1839 0.1 2.77 650 1030 1825 0.1 2.65 620 1045 1770 0.2 2.70 630 1040 1745 0.2 2.55 600 1060 1696 0.3 2.62 610 1050 1670 0.3 2.53 590 1065 1611 0.4 2.53 590 1060 1585 0.4 2.46 575 1070 High 1510 0.5 2.44 560 1070 1480 0.5 2.37 550 1080 1418 0.6 2.36 540 1085 1405 0.6 2.31 535 1090 Speed Tap Low Med High Notes • Assumes dry coil with filter in place; SCFM correction for wet coil = 4% • Five-ton models are shipped from the factory with speed tap set on T4. SS-DSH3 www.daikinac.com 15 Airflow Data — 4 Tons Standard Belt Drive — Down Shot ESP (" W.C.) Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.1 --- --- --- --- --- --- --- --- 1721 0.42 1588 0.34 0.2 --- --- --- --- --- --- 1756 0.47 1582 0.39 1449 0.33 0.3 --- --- --- --- 1736 0.52 1604 0.44 1437 0.37 1282 0.31 0.4 --- --- 1765 0.54 1601 0.49 1452 0.41 1286 0.34 1109 0.28 0.5 1802 0.53 1653 0.51 1458 0.46 1306 0.38 1114 0.32 --- --- 0.6 1701 0.56 1525 0.48 1314 0.43 1152 0.36 --- --- --- --- 0.7 1593 0.54 1406 0.46 1160 0.40 956 0.33 --- --- --- --- 0.8 1446 0.51 1247 0.43 982 0.36 --- --- --- --- --- --- 0.9 1317 0.48 1072 0.39 --- --- --- --- --- --- --- --- 1.0 1145 0.44 --- --- --- --- --- --- --- --- --- --- High Static Belt Drive — Down Shot ESP (" W.C.) 16 Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.6 --- --- --- --- --- --- --- --- --- --- 1634 0.52 0.7 --- --- --- --- --- --- --- --- 1705 0.59 1520 0.49 0.8 --- --- --- --- --- --- 1753 0.64 1576 0.56 1378 0.47 0.9 --- --- --- --- --- --- 1644 0.61 1447 0.52 1237 0.43 1.0 --- --- --- --- 1727 0.69 1535 0.58 1294 0.49 1070 0.40 1.1 --- --- --- --- 1605 0.66 1392 0.54 1144 0.45 --- --- 1.2 --- --- 1745 0.76 1483 0.62 1232 0.50 974 0.42 --- --- 1.3 1783 0.87 1586 0.71 1331 0.58 1068 0.46 --- --- --- --- 1.4 1658 0.83 1427 0.66 1177 0.53 --- --- --- --- --- --- 1.5 1533 0.78 1296 0.62 1019 0.50 --- --- --- --- --- --- 1.6 1387 0.73 1123 0.57 --- --- --- --- --- --- --- --- 1.7 1236 0.68 --- --- --- --- --- --- --- --- --- --- 1.8 1096 0.65 --- --- --- --- --- --- --- --- --- --- www.daikinac.com SS-DSH3 Airflow Data — 4 Tons (cont.) Standard Belt Drive — Horizontal ESP (" W.C.) Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.1 --- --- --- --- --- --- --- --- --- --- 1726 0.37 0.2 --- --- --- --- --- --- --- --- 1720 0.43 1575 0.36 0.3 --- --- --- --- 1888 0.57 1744 0.48 1562 0.41 1398 0.34 0.4 --- --- --- --- 1740 0.54 1579 0.45 1398 0.38 1217 0.31 0.5 --- --- 1797 0.56 1586 0.51 1420 0.42 1216 0.36 1004 0.28 0.6 1849 0.62 1658 0.53 1429 0.48 1252 0.40 997 0.32 --- --- 0.7 1731 0.59 1528 0.51 1266 0.45 1039 0.36 --- --- --- --- 0.8 1572 0.55 1355 0.47 1068 0.41 --- --- --- --- --- --- 0.9 1431 0.52 1171 0.43 --- --- --- --- --- --- --- --- 1.0 1245 0.48 987 0.39 --- --- --- --- --- --- --- --- 1.1 1059 0.44 --- --- --- --- --- --- --- --- --- --- High-Static Belt Drive — Horizontal ESP (" W.C.) Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.6 --- --- --- --- --- --- --- --- --- --- 1776 0.57 0.7 --- --- --- --- --- --- --- --- --- --- 1652 0.54 0.8 --- --- --- --- --- --- --- --- 1713 0.61 1498 0.51 0.9 --- --- --- --- --- --- 1787 0.67 1573 0.57 1345 0.47 1.0 --- --- --- --- --- --- 1668 0.63 1407 0.53 1163 0.44 1.1 --- --- --- --- 1745 0.71 1513 0.59 1243 0.49 960 0.40 1.2 --- --- --- --- 1612 0.68 1339 0.54 1059 0.46 --- --- 1.3 --- --- 1724 0.78 1447 0.63 1161 0.50 --- --- --- --- 1.4 1802 0.90 1551 0.72 1279 0.58 --- --- --- --- --- --- 1.5 1667 0.85 1409 0.67 1108 0.54 --- --- --- --- --- --- 1.6 1508 0.80 1221 0.62 --- --- --- --- --- --- --- --- 1.7 1343 0.74 1005 0.56 --- --- --- --- --- --- --- --- 1.8 1191 0.70 --- --- --- --- --- --- --- --- --- --- SS-DSH3 www.daikinac.com 17 Airflow Data — 5 Tons Standard Direct Drive Motor — Horizontal CFM Static Amps Watts RPM Standard Direct Drive Motor — Down Shot Speed Tap CFM Static Amps Watts RPM 1225 0.1 1.4 175 605 1205 0.1 1.47 180 635 1170 0.2 1.46 180 645 1150 0.2 1.54 185 675 1085 0.3 1.54 180 690 1065 0.3 1.59 185 730 1015 0.4 1.62 185 735 980 0.4 1.68 195 760 880 0.5 1.74 190 790 860 0.5 1.79 200 810 835 0.6 1.77 210 815 800 0.6 1.82 220 840 1425 0.1 1.80 230 670 1375 0.1 1.94 235 690 1330 0.2 1.96 240 705 1300 0.2 2.01 245 720 1260 0.3 2.00 250 735 1230 0.3 2.05 255 750 1210 0.4 2.10 260 770 1180 0.4 2.15 265 790 1135 0.5 2.16 265 810 1100 0.5 2.22 275 830 1040 0.6 2.28 280 860 1005 0.6 2.33 285 890 T1 T2 1000 0.7 2.38 290 885 970 0.7 2.43 295 900 940 0.8 2.46 300 925 915 0.8 2.51 310 940 870 0.9 2.52 310 955 845 0.9 2.57 315 980 1840 0.1 3.30 425 810 1790 0.1 3.37 573 948 1800 0.2 3.37 435 830 1745 0.2 3.40 580 965 1740 0.3 3.45 450 865 1700 0.3 3.49 595 985 1690 0.4 3.52 465 890 1650 0.4 3.56 606 1007 1635 0.5 3.58 475 920 1580 0.5 3.63 616 1035 1535 0.6 3.64 490 945 1515 0.6 3.71 626 1059 1505 0.7 3.70 500 970 1480 0.7 3.75 648 1079 150 0.8 3.80 510 995 1420 0.8 3.84 648 1100 1405 0.9 3.81 530 1035 1375 0.9 3.85 652 1117 2005 0.1 4.30 575 880 1920 0.1 4.48 650 976 1965 0.2 4.41 590 900 1910 0.2 4.57 620 940 1895 0.3 4.52 610 930 1850 0.3 4.66 635 965 1835 0.4 4.63 620 955 1795 0.4 4.78 655 990 1790 0.5 4.75 635 980 1760 0.5 4.84 670 1020 1745 0.6 4.84 650 1005 1710 0.6 4.96 685 1045 1695 0.7 4.91 660 1030 1640 0.7 5.06 675 1065 1650 0.8 5.03 675 1055 1610 0.8 5.19 690 1090 1600 0.9 5.10 675 1080 1560 0.9 5.22 700 1125 2120 0.1 5.10 690 930 2090 0.1 5.35 720 970 2075 0.2 5.15 710 950 2040 0.2 5.38 740 990 2025 0.3 5.23 720 975 1985 0.3 5.70 755 1025 1975 0.4 5.35 735 995 1930 0.5 5.46 750 1020 1875 0.6 5.59 770 1835 0.7 5.64 1795 0.8 5.73 1735 0.9 5.82 T3 T4 1935 0.4 5.44 760 1035 1900 0.5 5.82 780 1050 1040 1855 0.6 5.73 800 1075 780 1065 1810 0.7 5.69 810 1090 790 1090 1750 0.8 5.82 825 1120 805 1110 1680 0.9 6.13 790 1128 T5 Speed Tap T1 T2 T3 T4 T5 Notes • Assumes dry coil with filter in place; SCFM correction for wet coil = 4% • Five-ton models are shipped from the factory with speed tap set on T4. 18 www.daikinac.com SS-DSH3 Airflow Data — 5 Tons (cont.) Standard Belt Drive — Down Shot ESP (" W.C.) Turns Open 0 1 2 CFM 3 5 BHP CFM BHP CFM BHP 2115 0.56 1961 0.50 1816 0.41 0.67 2002 0.53 1855 0.47 1703 0.39 2047 0.63 1885 0.52 1751 0.44 1597 0.36 0.71 1941 0.59 1790 0.50 1633 0.42 1466 0.33 2030 0.68 1834 0.55 1681 0.45 1514 0.39 1314 0.30 0.69 1909 0.65 1716 0.51 1550 0.43 1367 0.37 --- --- 1951 0.72 1788 0.62 1595 0.47 1425 0.39 1212 0.35 --- --- 0.8 1840 0.70 1687 0.59 1465 0.43 1278 0.36 --- --- --- --- 0.9 1728 0.65 1558 0.54 1330 0.39 --- --- --- --- --- --- 1.0 1622 0.63 1432 0.50 1192 0.37 --- --- --- --- --- --- 1.1 1491 0.60 1288 0.46 --- --- --- --- --- --- --- --- 1.2 1325 0.57 --- --- --- --- --- --- --- --- --- --- CFM BHP CFM BHP 2021 0.87 1854 0.72 BHP CFM BHP 0.1 --- --- --- --- 0.2 --- --- --- --- 2153 0.3 --- --- --- --- 0.4 --- --- 2142 0.5 2170 0.67 0.6 2062 0.7 BHP 4 CFM CFM High-Static Belt Drive — Down Shot ESP (" W.C.) Turns Open 0 1 2 3 CFM 4 BHP 5 CFM BHP CFM BHP CFM BHP 0.6 --- --- --- --- --- --- 0.7 --- --- --- --- --- --- 2138 0.91 1928 0.83 1760 0.69 0.8 --- --- --- --- --- --- 2017 0.87 1813 0.80 1623 0.66 0.9 --- --- --- --- 2110 0.97 1897 0.83 1690 0.78 1486 0.62 1.0 --- --- 2145 1.07 1994 0.93 1786 0.79 1569 0.72 1361 0.59 1.1 --- --- 2047 1.03 1886 0.90 1684 0.76 1446 0.67 1233 0.55 1.2 2156 1.16 1949 1.00 1778 0.86 1552 0.71 1305 0.63 --- --- 1.3 2050 1.12 1851 0.97 1661 0.81 1441 0.68 --- --- --- --- 1.4 1944 1.09 1748 0.93 1534 0.77 1298 0.64 --- --- --- --- 1.5 1845 1.06 1627 0.88 1413 0.72 --- --- --- --- --- --- 1.6 1742 1.01 1527 0.83 1299 0.68 --- --- --- --- --- --- 1.7 1649 0.97 1400 0.79 --- --- --- --- --- --- --- --- 1.8 1526 0.93 1274 0.75 --- --- --- --- --- --- --- --- SS-DSH3 www.daikinac.com 19 Airflow Data — 5 Tons (cont.) Standard Belt Drive — Horizontal ESP (" W.C.) Turns Open 0 1 2 3 CFM 4 BHP CFM BHP 2203 0.57 2041 0.47 0.61 2084 0.54 1914 0.45 2118 0.60 1967 0.51 1794 0.42 0.68 2011 0.58 1835 0.49 1647 0.39 2061 0.64 1889 0.53 1701 0.45 1477 0.36 0.73 1928 0.62 1742 0.51 1536 0.43 1308 0.34 2009 0.70 1792 0.58 1601 0.47 1362 0.40 --- --- 0.80 1895 0.67 1646 0.54 1436 0.44 1188 0.36 --- --- 1941 0.75 1750 0.62 1495 0.50 1271 0.40 --- --- --- --- 1.0 1823 0.73 1609 0.58 1339 0.48 --- --- --- --- --- --- 1.1 1675 0.69 1448 0.54 1183 0.45 --- --- --- --- --- --- 1.2 1487 0.65 1268 0.50 --- --- --- --- --- --- --- --- BHP CFM BHP CFM BHP 0.1 --- --- --- --- --- --- 0.2 --- --- --- --- --- --- 2248 0.3 --- --- --- --- --- --- 0.4 --- --- --- --- 2180 0.5 --- --- --- --- 0.6 --- --- 2145 0.7 2192 0.83 0.8 2067 0.9 BHP 5 CFM CFM High-Static Belt Drive — Horizontal ESP (" W.C.) Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.6 --- --- --- --- --- --- --- --- 2246 0.97 2060 0.80 0.7 --- --- --- --- --- --- --- --- 2142 0.93 1956 0.77 0.8 --- --- --- --- --- --- 2241 0.97 2014 0.89 1803 0.74 0.9 --- --- --- --- --- --- 2108 0.92 1878 0.86 1651 0.69 1.0 --- --- --- --- --- --- 1984 0.88 1743 0.80 1512 0.65 1.1 --- --- --- --- 2096 1.00 1871 0.84 1607 0.74 1370 0.62 1.2 --- --- 2166 1.11 1976 0.96 1724 0.79 1450 0.69 1201 0.57 1.3 --- --- 2057 1.07 1845 0.90 1601 0.75 1301 0.65 --- --- 1.4 2160 1.21 1942 1.03 1705 0.85 1443 0.71 --- --- --- --- 1.5 2050 1.18 1808 0.98 1570 0.80 1285 0.66 --- --- --- --- 1.6 1935 1.13 1697 0.92 1443 0.76 --- --- --- --- --- --- 1.7 1832 1.08 1556 0.88 1273 0.70 --- --- --- --- --- --- 1.8 1696 1.03 1415 0.83 --- --- --- --- --- --- --- --- Air Flow Pressure Drop of Down Flow Economizer Airflow Pressure Drop of Downflow Economizer for 3 to 6 Ton Rofftop Units (100% Return Air) SCF, 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 in WG 0.02 0.04 0.05 0.07 0.09 0.12 0.14 0.17 0.21 0.24 0.28 20 www.daikinac.com SS-DSH3 Crankcase Heater, High Efficiency MERV 13 Air Filter Option High Efficiency MERV 13 Air Filter Option Flanders Pre Pleat M13 Air Velocity vs Resistance (Test Size: 24" x 24" x 2" High Capacity) 0.50 0.45 2" Deep Resistance (in. w.g.) 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 0 100 200 300 400 500 600 700 Air Velocity (FPM) Tonnage: Filter Nominal Size: Part Number: Order QTY: 3 24 x 24 x 2 0160L00203 1 4 14 x 20 x 2 0160L00204 4 5, 6, 7.5 16 x 20 x 2 0160L00205 4 7.5(HP), 8.5, 10 16 X 24 X 2 0160L00206 4 12.5 20 x 25 x 2 0160L00202 4 15, 20 20 x 25 x 2 0160L00202 6 25 20 X 20 X 2 0160L00201 8 Crankcase Heater Selection Table ZP/ZPS… Compressor Diameter 16-31 5.5" 39-83 103-137 6.58/7.3" 9.14” DC*,DT* & DS* Tonnage Compressor Voltage 230V 460V 575V 0163R00002S 0163R00031S 0163R00032S 0130L00017S 0130L00020S 230V 0130L00018S 0130L00021S 0130L00019S 0130L00022S Compressor Voltage 460V Crankcase Heater Watts 40 70 90 575V Crankcase Heater Watts 3 Ton 0163R00002S 0163R00031S 0163R00032S 40 4 Ton-12.5 Ton 0130L00017S 0130L00018S 0130L00019S 70 15-20 Ton** 0130L00017S 0130L00018S 0130L00019S 70 25 Ton 0130L00020S 0130L00021S 0130L00022S 90 *Includes C,G&H models. **If Compressor Diameter is 9.14” then use 25 Ton Crankcase heaters. SS-DSH3 www.daikinac.com 21 Expanded Heating Data DSH036* MBh T/R kW COP EER HI PR LO PR 65 46.3 36 3.25 4.17 14.2 421 143 60 43.8 34 3.18 4.04 13.8 403 133 55 41.2 32 3.11 3.89 13.3 388 124 50 38.6 30 3.04 3.72 12.7 371 114 47 36.8 28 2.97 3.63 12.4 362 108 45 35.7 28 2.90 3.61 12.3 355 104 40 33.1 26 2.83 3.44 11.7 342 95 Outdoor Ambient Temperature 35 30 25 20 30.6 24.8 22.9 21.1 24 19 18 16 2.76 2.69 2.62 2.55 3.25 2.71 2.57 2.43 11.1 9.2 8.8 8.3 328 314 300 288 85 77 68 60 17 19.9 15 2.48 2.36 8.0 281 56 15 19.2 15 2.41 2.34 8.0 276 54 10 17.2 13 2.34 2.16 7.4 265 46 5 15.3 12 2.27 1.97 6.7 255 39 0 13.3 10 2.20 1.78 6.1 245 33 -5 11.4 9 2.12 1.57 5.3 236 29 -10 9.3 7 2.05 1.33 4.5 228 23 65 57.6 33 3.96 4.26 14.5 412 137 60 54.5 32 3.88 4.12 14.1 395 127 55 51.3 30 3.80 3.96 13.5 380 119 50 48.0 28 3.72 3.78 12.9 363 110 47 45.8 27 3.64 3.68 12.6 355 104 45 44.4 26 3.56 3.65 12.5 348 100 40 41.2 24 3.48 3.47 11.8 335 92 Outdoor Ambient Temperature 35 30 25 20 38.0 31.4 29.0 26.7 22 18 17 15 3.40 3.32 3.24 3.16 3.28 2.77 2.62 2.48 11.2 9.5 9.0 8.5 321 308 294 282 82 74 66 58 17 25.2 15 3.08 2.40 8.2 275 54 15 24.3 14 3.00 2.37 8.1 270 52 10 21.8 13 2.92 2.19 7.5 260 44 5 19.3 11 2.84 1.99 6.8 250 38 0 16.9 10 2.76 1.79 6.1 240 32 -5 14.4 8 2.68 1.57 5.4 231 28 -10 11.8 7 2.60 1.33 4.5 223 22 65 72.3 33 4.74 4.47 15.3 384 131 60 68.4 32 4.66 4.30 14.7 368 122 55 64.4 30 4.59 4.11 14.0 354 114 50 60.2 28 4.52 3.90 13.3 339 105 47 57.5 27 4.45 3.78 12.9 331 99 45 55.7 26 4.38 3.73 12.7 324 95 40 51.7 24 4.31 3.52 12.0 312 88 17 33.4 15 3.95 2.48 8.5 257 51 15 32.2 15 3.88 2.43 8.3 252 49 10 28.9 13 3.81 2.22 7.6 242 42 5 25.6 12 3.74 2.01 6.9 233 36 0 22.3 10 3.66 1.79 6.1 224 30 -5 19.1 9 3.59 1.55 5.3 216 27 -10 15.6 7 3.52 1.30 4.4 208 21 DSH048* MBh T/R kW COP EER HI PR LO PR DSH060* Outdoor Ambient Temperature MBh T/R kW COP EER HI PR LO PR 35 47.7 22 4.24 3.30 11.3 299 78 30 41.7 19 4.16 2.93 10.0 287 70 Above information is for 70º indoor dry bulb; instantaneous capacity listed. High pressure measured at liquid line access fitting. Low pressure measured at compressor suction access fitting. 22 www.daikinac.com 25 38.4 18 4.09 2.75 9.4 274 63 20 35.4 16 4.02 2.58 8.8 263 55 kW = Total system power Amps: Unit Amps (comp+evap motor+condenser fan motor) SS-DSH3 Heat Kit Electrical Data — 3 Tons Model and Heat Kit Usage MCA¹ @ 208 / 240V MOP² (amps) @ 208 / 240V DSH036***1D*** 25 40 --- --- EHK1-10 77 80 10 1250-1350 CFM EHK1-15 103 110 15 1400-1440 CFM DSH036***3D*** Actual kW & BTU @ 240V Recommended Airflow Range 17 25 --- --- EHK3-10 41 / 47 45 / 50 10 1250-1350 CFM EHK3-15 54 / 62 60 / 70 15 1400-1440 CFM 18 25 --- --- EHK3-10 42 / 48 45 / 50 10 1250-1350 CFM EHK3-15 55 / 63 60 / 70 15 1400-1440 CFM MCA¹ @ 480V MOP² (amps) @ 480V Actual kW & BTU @ 480V Recommended Airflow Range DSH036***4B*** 10 15 --- --- EHK4-10 25 25 10 1250-1350 CFM EHK4-15 33 35 15 1400-1440 CFM MCA¹ @ 575V MOP² (amps) @ 575V Actual kW & BTU @ 575V Recommended Airflow Range DSH036***7B*** 8 15 --- --- EHK7-10 20 25 10 1400-1475 CFM EHK7-15 26 30 15 1575-1650 CFM DSH036***3B*** Model and Heat Kit Usage Model and Heat Kit Usage ¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection device kW Correction Factors kW Correction Factor for 1- & 3-Phase Units Supply Voltage Correction Factor 240 230 220 210 208 1 0.93 0.82 0.78 0.76 kW Correction Factor for 480V Units Actual Voltage 460 440 430 Correction Factor 0.92 0.84 0.8 For other voltage use voltage² / 480² kW Correction Factor for 575V Units Supply Voltage 560 550 540 Correction Factor 0.95 0.91 0.88 Multiply rated kW by correction factor to get actual kW SS-DSH3 www.daikinac.com 23 Heat Kit Electrical Data — 4 Tons Model and Heat Kit Usage MCA¹ @ 208 / 240V MOP² (amps) @ 208 / 240V Actual kW & BTU @ 240V Recommended Airflow Range DSH048***1D*** 29 45 --- --- EHK1-10 81 90 10 1400-1800 CFM EHK1-15 107 110 15 1575-1800 CFM EHK1-18 123 125 18 1575-1800 CFM DSH048***3D*** 21 30 --- --- EHK3-10 44 / 51 45 / 60 10 1400-1800 CFM EHK3-15 57 / 66 60 / 70 15 1575-1800 CFM EHK3-18 65 / 75 70 / 80 18 1575-1800 CFM 22 30 --- --- EHK3-10 45 / 52 45 / 60 10 1400-1800 CFM EHK3-15 58 / 67 60 / 70 15 1575-1800 CFM EHK3-18 66 / 76 70 / 80 18 1575-1800 CFM MCA¹ @ 480V MOP² (amps) @ 480V Actual kW & BTU @ 480V Recommended Airflow Range DSH048***4B*** 10 15 --- --- EHK4-10 25 30 10 1400-1800 CFM EHK4-15 33 35 15 1575-1800 CFM EHK4-18 37 40 18 1575-1800 CFM MCA¹ @ 575V MOP² (amps) @ 575V Actual kW & BTU @ 575V Recommended Airflow Range DSH048***7B*** 8 15 --- --- EHK7-10 21 25 10 1400-1800 CFM EHK7-15 27 30 15 1575-1800 CFM EHK7-18 31 35 18 1575-1800 CFM DSH048***3B*** Model and Heat Kit Usage Model and Heat Kit Usage ¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection device kW Correction Factors kW Correction Factor for 1- & 3-Phase Units Supply Voltage Correction Factor 240 230 220 210 208 1 0.93 0.82 0.78 0.76 kW Correction Factor for 480V Units Actual Voltage 460 440 430 Correction Factor 0.92 0.84 0.8 For other voltage use voltage² / 480² kW Correction Factor for 575V Units Supply Voltage 560 550 540 Correction Factor 0.95 0.91 0.88 Multiply rated kW by correction factor to get actual kW 24 www.daikinac.com SS-DSH3 Heat Kit Electrical Data — 5 Tons Model and Heat Kit Usage MCA¹ @ 208 / 240V MOP² (amps) @ 208 / 240V Actual kW & BTU @ 240V Recommended Airflow Range 40 92 118 144 29 51 / 59 64 / 74 77 / 89 25 48 / 55 61 / 70 74 / 85 60 100 125 150 45 60 / 60 70 / 80 80 / 90 40 50 / 60 70 / 80 80 / 90 --10 15 20 --10 15 20 --10 15 20 --1750-2250 CFM 1750-2250 CFM 1850-2250 CFM --1750-2250 CFM 1750-2250 CFM 1850-2250 CFM --1750-2250 CFM 1750-2250 CFM 1850-2250 CFM MCA¹ @ 480V MOP² (amps) @ 480V Actual kW & BTU @ 480V Recommended Airflow Range 12 27 35 43 20 30 40 45 --10 15 20 --1750-2250 CFM 1750-2250 CFM 1850-2250 CFM MCA¹ @ 575V MOP² (amps) @ 575V Actual kW & BTU @ 575V Recommended Airflow Range 10 23 29 35 15 25 30 40 --10 15 20 --1750-2250 CFM 1750-2250 CFM 1850-2250 CFM DSH060***1D*** EHK1-10 EHK1-15 EHK1-20 DSH060***3D*** EHK3-10 EHK3-15 EHK3-20 DSH060***3B*** EHK3-10 EHK3-15 EHK3-20 Model and Heat Kit Usage DSH60***4B*** EHK4-10 EHK4-15 EHK4-20 Model and Heat Kit Usage DSH060***7B*** EHK7-10 EHK7-15 EHK7-20 ¹ Minimum Circuit Ampacity ² Maximum Overcurrent Protection Device kW Correction Factors kW Correction Factor for 1- & 3-Phase Units Supply Voltage Correction Factor 240 230 220 210 208 1 0.93 0.82 0.78 0.76 kW Correction Factor for 480V Units Actual Voltage 460 440 430 Correction Factor 0.92 0.84 0.8 For other voltage use voltage² / 480² kW Correction Factor for 575V Units Supply Voltage 560 550 540 Correction Factor 0.95 0.91 0.88 Multiply rated kW by correction factor to get actual kW SS-DSH3 www.daikinac.com 25 26 www.daikinac.com 33.805 FRONT VIEW 73.945 FLUE/VENT OUTLET GAS LINE ENTRANCE COMBUSTION AIR INLET (GAS UNITS) ALL DIMENSIONS GIVEN ARE IN INCHES ALL DIMENSIONS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 11.265 TOP VIEW 10.060 6.196 3 THRU 5 TON COMMERCIAL DSH036-060 4.475 12.000 SUPPLY AIR DUCT CONDENSATE DRAIN OUTLET 17.000 RIGHT END VIEW 48.196 LIFTING SHACKLE HOLES BOTH SIDES AND ENDS 7.165 31.540 20.853 FORK HOLES BOTH SIDES AND BOTH ENDS 11.000 RETURN AIR DUCT Dimensions SS-DSH3 Dimensions (cont.) CONDENSATE DRAIN BOTTOM EXIT 19.470 5.104 MOD 3 TON GAS, HT PUM 4 TON GAS, HT PUM 5 TON GAS, HT PUM 6 TON GAS, HT PUM 12.000 SUPPLY AIR DUCT 17.000 48.312 23.442 20.905 11.000 6.192 5.558 25.000 RETURN AIR DUCT 74.061 BASE PAN VIEW (VIEWED FROM TOP) CONDENSATE DRAIN BOTTOM EXIT MODEL TONNAGES 3 TON COMMERCIAL GAS, HT PUMP, AIR CONDITIONER 4 TON COMMERCIAL GAS, HT PUMP, AIR CONDITIONER 5 TON COMMERCIAL GAS, AIR CONDITIONER 5 TON COMMERCIAL HT PUMP "A" "B" "C" 38.840 16.555 26.055 38.840 16.555 26.055 38.840 16.555 26.055 42.840 20.555 30.055 7.984 LINE WIRE ENTRANCE "A" "C" "B" 8.555 TSTAT WIRE ENTRANCE 5.872 10.372 LEFT END VIEW TURN AIR DUCT 74.061 BASE PAN VIEW EWED FROM TOP) SS-DSH3 www.daikinac.com 27 Unit Clearances Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 48” on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit’s fresh-air intake. Electrical Entrance Locations High-Voltage Entrance (Remove Plug) 12⅜” 3½” Dia. 30¼” Power Thru the Curb 47½” Low-Voltage Entrance 7½” Corner & Center-of-Gravity Locations 3-Ton Weights 4-Ton Weights 5-Ton Weights Corner Weight (A) 131 133 145 Corner Weight (B) 182 184 205 Corner Weight (C) 112 113 125 Corner Weight (D) 155 156 175 Unit Shipping Weight 605 610 675 Unit Operating Weight 580 585 650 Unit Weights Return 30” Condenser Coil Evaporator Coil Supply Note: Weights are calculated without accessories installed. Compressor 37” 28 www.daikinac.com SS-DSH3 Roof Curb Installation — Rigging Provisions for forks have been included in the unit base frame. No other fork locations are approved. • Unit must be lifted by the four lifting holes located at the base frame corners. • Lifting cables should be attached to the unit with shackles. • The distance between the crane hook and the top of the unit must not be less than 60”. • Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual. Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct. To assist in determining rigging requirements, unit weights are shown below. Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. • Determine sufficient structural support before locating and mounting the curb and package unit. • Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. Cantilevered-type curbs are not available from the factory. • Contractor furnishes curb insulation, cant strips, flashing, and general roofing material. • Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate supply and return duct openings. Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended. See the manual shipped with the roof curb for assembly and installation instructions. Top View 3-D View 1.625 TYP. Insulated Panels 70¾ 70.75 O.D. 3 3 14 40¼ S/A 14 x 20 Supply Opening 14.625 20 20 37 40.25 I.D. O.D. 16.000 3 14 31⅝ x 14 Return Opening O 1.750 14 ¾ 15/6 32.875 31.625 R/A 15.250 14 1⅜ SS-DSH3 www.daikinac.com 67.5 I.D. 29 Wiring Diagram — DSH036*/DSH048* SINGLE PHASE 208-230V/1/60HZ DIRECT DRIVE RD PU BK 1 C C C R R C BK BK PU PLF 2 RD PU OR PU 0-RV BR RD WH Y C H F RCCF BK R-PS1 DFT R-DFT DF2 DF1 Y PS2 RD BK RD 3 6 9 2 5 8 1 4 7 PLF 1 YL RD GR PU WH OR BL BR RD BR BL YL RD RD BL PU PU BK EM BR DFT 3 SPEED BL BK BK BC RVC EM BR 3 SPEED RD PU BR BK BC PU L1 C T1 C CH COMP S C 2 POLE ONLY SEE NOTE 8 H DF2 DF1 HVDR RCCF F EM BR 208-240V SEE NOTE 3 3 1 DFT RVC DFT C-RV DC W Y O-RV R R O BR DFT R-DFT PS2 R-PS1 C CNT LPS R 7 4 8 5 9 6 C HPS TABLE 1 TABLE 2 SPEED TAPS ALTERNATE MOTOR WIRING RD LOW COLOR TERMINATION BL RD MED COM (EBTDR) BK HIGH BK M1 (EBTDR) BL M2 (EBTDR) PU PIN 1 (24V XFMR) SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION JUNCTION TERMINAL PLF INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION 9 8 7 6 5 4 3 2 1 EBTDR PLF2 R S1 S2 O R W2 W1 Y2 Y1 THERMOSTAT ++ G R XFMR C BLOWER INTERLOCK RELAY CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER BLOWER CAPACITOR USE N.E.C. CLASS 2 WIRE 5. ECONOMIZER PLUG LOCATED IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH TO ECONOMIZER ACCESSORY. 6. DIAGRAM SHOWS FACTORY SPEED TAP SETTINGS. 7. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 8. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION. 9. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR CONNECTED TO ANY OTHER COMMON (24V). TR 24V G SMOKE/FIRE DETECTOR REPLACES JUMPER BL/PK ++ 2 C T H E R M O S T A T Y1 Y2 R G W1 W2 O C S2 S1 BL/PK TB1 TR BC NOTES: 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE M1 OR M2 WIRE TO COM TERMINAL ON EBTDR AND PLACE WIRE REMOVED FROM COM ON EMPTY M1 OR M2 TERMINAL. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. USE COPPER CONDUCTORS ONLY. CM EBTDR BK HPS COMPONENT LEGEND BIR C CCR CH CHS CM COMP DC DFT ECON EM GND HPS HVDR LPS LVDR LVJB PLF RVC RCCF C T2 R SEE NOTE 7 PU PU COMP L2 2 POLE ONLY SEE NOTE 8 BK GR TB1 CM SUPPLY VOLTAGE 208-240/1/60 CHS CH T3 T2 T1 ALTERNATE MOTOR 6-WIRES SEE TABLE 1 RD YL RD YL PU RD GR WH BR OR BL BL BR PK RD RD CHS BK YL RD CONTROL BOX BK RD YL 3 6 9 2 5 8 1 4 7 LVJB WH W PU GND OR RD GR BR PU C-RV RD BK BK BK BIR 0 HVDR SEE NOTE 2 L1 T1 PU 3 DC 0 LVDR L2 T2 2 CNT YL RD RD BR BR CCR PK BL YL/PK YL 2 0 8 2 4 0 / 1 / 6 0 SWITCH (PRESS.) OVERCURRENT PROT. DEVICE EQUIPMENT GROUND FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER W W G WH GR R RD R Y1 YL Y G Y2 C BL O OR C O STAT TB1 WITH ECONOMIZER OPTION W G WH GR R RD Y1 YL W G R Y Y2 C BL O OR TB1 C O STAT 2 STAGE COOLING W G WH GR W FIELD SPLICE R RD Y1 YL R Y1 SWITCH (TEMP) Y2 PK Y2 FIELD GROUND IGNITER G C BL C O OR O STAT TB1 ⚡ LPS SEE NOTE 7 RD BL BL COM K1 SEE NOTE #2 NC SPEED M1 M2 UP BL BK BK YL/PK 24V RD NO K1 BK BL BL High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. R XFMR-R XFMR-C C BL TR ⚠ Warning GR EBTDR SEE NOTE 8 SEE NOTE 9 3 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BL 2 208 240 C ++ G 1 BR RD ++ BK SEE NOTE 5 208-240/1/60 0140L02904-B 30 www.daikinac.com SS-DSH3 Wiring Diagram — DSH060* SINGLE PHASE 208-230V/1/60HZ DIRECT DRIVE SEE NOTE 7 BK BL BK RD RD T2 L2 L2 YL/PK PK BL C BK BK BL PU YL C C R R C CNT OR 0 0 WH BR BK 0-RV WH W Y HVDR PU Y YL R-PS1 DFT R-DFT D2 C H BK PS2 RCCF YL WH RD C-RV F RD 3 6 9 2 5 8 1 4 7 WH WH BR RD BR BL RD PU WH PU RD SEE NOTE 2 RD 1 2 3 4 5 EM C L G N DFT BL PU BK BL LVJB YL PU RD GR GR PLF 1 1 5 OR BR YL BR BK YL BK RD TB1 YL PU BL/PK CM CONTROL BOX BK REPLACE JUMPER WITH SMOKE/FIRE DETECTOR BL/PK CH HPS GR RVC L1 COMPONENT LEGEND L2 C CCR CH CHS CM COMP DC DFT ECON EM GND HPS HVDR LPS LVDR LVJB PLF RVC RCCF SUPPLY VOLTAGE 208-240/1/60 C T1 C T2 R C COMP S SEE NOTE 7 H C DF1 DF2 HVDR RCCF F CM TB1 TR SEE NOTE 6 CHS N EM 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM "3" AND "4" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. USE COPPER CONDUCTORS ONLY L G 208-240V SEE NOTE 3 2 3 ++ TR DFT 24V RVC R C-RV O-RV R O W USE N.E.C. CLASS 2 WIRE 5. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY. 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION. 1 R-DFT DC R-PS1 Y DFT PS2 C CNT SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION JUNCTION 1 2 3 4 5 LPS P 4 L F 5 1 6 SEE NOTE 2 EQUIPMENT GROUND TERMINAL C HPS FIELD GROUND PLUG CONNECTION FIELD SPLICE SWITCH (TEMP) SWITCH (PRESS.) IGNITER OVERCURRENT PROT. DEVICE 9 8 7 6 5 4 3 2 1 PLF2 S2 O R W2 W1 Y2 THERMOSTAT Y1 G C FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK RD RED PU PURPLE YL YELLOW WH WHITE BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER W W G WH GR R RD R Y1 YL Y G Y2 C BL O OR C O STAT TB1 WITH ECONOMIZER OPTION W G WH GR R RD Y1 YL W G R Y SEE NOTE 5 C BL O OR TB1 C O STAT 2 STAGE COOLING W WH GR W G R RD Y1 YL R Y1 Y2 PK Y2 C BL C O OR O STAT TB1 G ++ S1 LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE Y2 INTERNAL TO INTEGRATED CONTROL EM C SEE NOTE 6 FACTORY WIRING CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR EQUIPMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR COMPRESSOR AND FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER NOTES: CH T H BK E R M O S T A T BK COMP RD Y1 Y2 R G W1 W2 O C S2 S1 WH BR OR OR BL BL BL RD PK T2 T1 T3 BK GR BK GND OR RD GR PLF 2 3 6 9 PU 2 5 8 YL 1 4 7 DC LVDR DF1 BK PU CCR TB1 SEE NOTE 4 YL PU BL GR WH L1 T1 PU BR YL RD 2 0 8 L1 2 4 0 / NOTE 6 1 RD / 6 0 CHS NOTE 5 RD BK 24V ⚡ 3 240 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 2 208 TR ⚠ Warning 1 C RD RD BL BL Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. YL/PK LPS ++ RD ++ WH 208-240/1/60 0140L05410-A SS-DSH3 www.daikinac.com 31 Wiring Diagram — DSH036*/ DSH048*/ DSH060* THREE PHASE 208-230V / 3 / 60HZ BELT DRIVE WIRING DIAGRAMS DSH036*/DSH048*/DSH060* (B) THREE PHASE 208-230V/3/60HZ BELT DRIVE T3 RD RD T2 BK BK L3 L2 L2 C T1 L1 C C C R R DC CCR BL PU CNT OR 0 YL GR 0 LVD R RD 0-RV W L2 R-PS1 DFT DF2 DF1 R-DFT Y RD L1 BK RCCF BK Y HVDR RD OR YL WH C-RV BK BR PS2 PU C F RD L3 C WH PU 3 6 9 2 5 8 1 4 7 PLF1 RD T3 T1 T2 BK RD OR YL PU RD GR WH BR OR BL RD GR WH OR BL BL RD BR BR PK BR BL PU BC RD BK CH BK RD RD GR EM RD DFT CHS PU BK BR BK YL RD BK PU BL/PK CM COMP SEE NO TE 5 OR Y1 Y2 R G W1 W2 O C S2 S1 TB1 YL T H E R M O S T A T REPLACE JUMPER WITH SMOKE/FIRE DETECTOR BL/PK T3 T1 T2 BK RD PLF2 3 6 9 PU 2 5 8 1 4 7 YL BL HPS RVC COMPONENT LEGEND SUPPLY VOLTAGE 208-240/3/60 L1 CH CHS T1 C T2 T2 C L3 L2 SEE NO TE 5 BC C CCR CH CHS CM COMP DC DFT ECON EBTDE MR EM GND HPS HVDR LPS LVDR PLF RVC RCCF COMP C T3 T3 C DF2 DF1 HVDR R CC F F CM TB1 TR BLOWER CONTACTOR COMPRESSOR CONTACTOR RELAY CONTACTOR CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY EVAPORATOR MOTOR EQUIPMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER NOTES: T1 BC EM T3 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY BC T2 2 3 EBTDR R RVC ++ 208-240V BC 1 24V R G O-RV C-RV USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. 4. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 5. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. SEE NOTE 4 TR C SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION DFT R O W DFT R-DFT DC Y R-PS1 PS2 LPS P 4 L F 5 1 6 9 8 7 6 5 4 3 2 1 S2 O R W2 W1 Y2 THERMOSTAT Y1 G FIELD GROUND FIELD SPLICE SWITCH (TEMP) SWITCH (PRESS.) C HPS ++ S1 EBTDR EBTDR EQUIPMENT GROUND TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION BC R JUNCTION C CNT IGNITER OVERCURRENT PROT. DEVICE FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BLACK BLUE BROWN GREEN ORANGE PINK PURPLE RED WHITE YELLOW BLUE WITH PINK STRIP YELLOW WITH PINK STRIP BK BL BR GR OR PK PU RD WH YL BL/PK YL/PK THERMOSTAT FIELDWIRING ++ HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. BL GR ⚡ GND BL YL L1 SEENOTE 2 PU BR YL/PK YL/PK 2 0 8 2 4 0 / 3 / 6 0 PB L3 NO ECONOMIZER W G R Y1 Y2 WH GR RD YL W G R Y1 WH GR RD YL C O BL OR BL C C OR O O STAT TB1 WITH ECONOMIZER OPTION Y2 TB1 2 STAGE COOLING PLF2 W G R Y1 WH GR RD YL C O BL OR Y2 C SEE NOTE 3 208-240/3/60 0140L05412-A W G R Y TB1 PK W G R Y C O STAT High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. PK PU NC M2 BL BL YL BK ⚠ Warning TR 24V GR COM 3 208 240 RD NO SPEED M1 UP BL 2 1 C RD BK BL ++ LPS SEE NOTE 4 BL BK GR G EBTDR R K1 XFMR-R XFMR-C K1 C BL OR RD RD BR RD RD RD Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BK OR W G R Y1 Y2 C O STAT Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 35 32 www.daikinac.com SS-DSH3 Wiring Diagram — DSH036* / DSH048*DSH036* DSH060*(4B/7B)/DSH048* THREE PHASE 460/575V/3/60HZ BELT DRIVE (4B/7B)/DSH060* (4B/7B) THREE PHASE 460/575V/3/60HZ BELT DRIVE GR R XFMR-R XFMR-C C BL SPEED UP BL K1 NO K1 COM TR RD 24V PK PU NC M2 M1 BL 460 575 C BR GR BL 3 1 EBTDR T3 RD RD T2 C C C R R CCR YL/PK YL OR RD BK GR RD OR BK 1 RD RD 5 8 1 4 7 9 BR BL YL RD BL/PK BL/PK BK DFT PU BL BR YL BK T H E R M O S T A T Y1 Y2 R G W1 W2 O C S2 S1 TB1 CHS BL RD BK SEE NOTE 4 T3 T1 T2 CM HPS CH GR 6 CMR PU BK 3 2 PLF 1 2 RD BK EM 3 BK BL F RD BL CHR C RCCF PS2 R-PS1 DFT R-DFT DF2 DF1 BK YL YL PU RD RD GR GR WH WH BR OR OR BL BL RD BR BR PK BK RD RD T3 T2 WH PU PU Y L3 C T1 YL WH W BR BC OR PLF 2 3 6 9 3 2 5 8 PU 1 4 7 BR Y L2 RD RD C-RV HVDR L1 GR RD BK 0-RV BL GND OR 0 LVDR 4 6 0 5 7 5 / 3 / 6 0 L1 SEE NOTE 2 0 YL BL L2 BL PU CNT L2 L1 T1 BR DC L3 PU BR LPS YL/PK L3 C BK BK BL BK RD BL YL BL RD BK RD BK ⚡ BL RD COMP RD REPLACE JUMPER WITH SMOKE / FIRE DETECTOR RVC SEE NOTE 4 RD BL COMPONENT LEGEND L2 SUPPLY VOLTAGE 460-575/3/60 C T2 T2 T1 T1 C COMP C T3 T3 C L3 DF1 DF2 HVDR RCCF F CM SEE NOTE 4 CHR 3 T1 BC CH 1 T2 BC T3 EM 3 24V EBTDR R R BC 460V - 575V 1 G TB1 TR NOTES: TR C CMR RVC DF2 O-RV C-RV DF1 R DC O W R-PS1 Y R R HVDR R CHS DFT R-DFT C PS2 CNT LPS EBTDR EBTDR CHR P 4 L F 5 1 6 BC HPS SEE NOTE 4 BLOWER CONTACTOR CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CRANKCASE HEATER RELAY CONDENSER MOTOR CONDENSER MOTOR RELAY COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER ELECTRONIC BLOWER TIME DELAY EVAPORATOR MOTOR RELAY EVAPORATOR MOTOR EQUPIMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY FEMALE PLUG / CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105�C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY DFT R BC C CCR CH CHS CHR CM CMR COMP DC DFT ECON EBTD EMR EM GND HPS HVDR LPS LVDR PLF RVC RCCF C 9 8 7 PLF2 6 5 4 3 2 1 ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. 4. CRANKCASE HEATER, CRANKCASE HEATER RELAY, AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION SWITCH (PRESS.) OVERCURRENT PROT. DEVICE EQUIPMENT GROUND FIELD GROUND FIELD SPLICE SWITCH (TEMP) IGNITER FACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STRIP THERMOSTAT FIELD WIRING NO ECONOMIZER W S2 O R W2 W1 Y2 Y1 G C WH GR R RD R Y1 YL Y G Y2 C BL O OR C O STAT TB1 WITH ECONOMIZER OPTION W G WH GR W R RD R Y1 YL G Y Y2 C BL O OR TB1 C O STAT 2 STAGE COOLING W G WH GR R RD R Y1 YL Y1 Y2 PK Y2 W G C BL C O OR O STAT SEE NOTE 3 460-575/3/60 0140L05409-A THERMOSTAT ++ SS-DSH3 W G TB1 S1 ++ L1 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. G OR OR ⚠ Warning RD RD RD BR Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BK ++ UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. RING DIAGRAMS www.daikinac.com 33 Wiring Diagram — DSH036*/DSH048* THREE PHASE 208-230V/3/60HZ DIRECT DRIVE PU RD BR 1 BK C C C YL R T2 L2 CCR CNT BK GND BK BK PU BR YL PU BK 0-RV RD BR BL WH W FC Y R-PS1 DFT R-DFT C BK F RD 3 6 9 2 5 8 1 4 7 GR PU WH OR BL BR PLF 1 RD BR BL YL PU BK RD RD RD BL BK EM DFT 3 SPEED BL BK BK BC RVC EM BR 3 SPEED RD PU BR BK BC PU PU PU BL/PK YL Y1 Y2 R G W1 W2 O C S2 S1 TB1 SMOKE/FIRE DETECTOR REPLACES JUMPER BL/PK BK CM CH COMP RD HPS BK GR RD SEE NOTE 7 CHS SEE NOTE 7 C T1 T2 T1 COMP C T3 T3 C DF2 DF1 HVDR RCCF F CM SEE NOTE 7 CH CHS EM 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE M1 OR M2 WIRE TO COM TERMINAL ON EBTDR AND PLACE WIRE REMOVED FROM COM ON EMPTY M1 OR M2 TERMINAL. 3. FOR 208V TRANSFORMER OPERATION MOVE BK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. USE COPPER CONDUCTORS ONLY BR EBTDR 208-240V SEE NOTE 3 2 3 ++ 1 USE N.E.C. CLASS 2 WIRE 5. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY. 6. DIAGRAM SHOWS FACTORY SPEED TAP SETTINGS. 7. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR CONNECTED TO ANY OTHER COMMON (24V). TR 24V RVC R C-RV DC W Y O BR DFT O-RV R DFT R-DFT PS2 R-PS1 R 4 8 5 9 6 C CNT C HPS COLOR RD BK BL PU TERMINATION COM (EBTDR) M1 (EBTDR) M2 (EBTDR) PIN 1 (24V XFMR) SPEED TAPS RD BL BK PLF2 R S2 O R W2 W1 Y2 Y1 JUNCTION G C SWITCH (PRESS.) OVERCURRENT PROT. DEVICE EQUIPMENT GROUND FIELD GROUND LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BL BR GR OR PK PU RD WH YL BL/PK YL/PK THERMOSTAT FIELD WIRING NO ECONOMIZER WH GR R RD R Y1 YL Y G Y2 C BL O OR C O STAT TB1 WITH ECONOMIZER OPTION W G WH GR R RD Y1 YL W G R Y Y2 C BL O OR TB1 2 STAGE COOLING W IGNITER W W G FIELD SPLICE SEE NOTE 5 www.daikinac.com BLACK BLUE BROWN GREEN ORANGE PINK PURPLE RED WHITE YELLOW BLUE WITH PINK STRIP YELLOW WITH PINK STRIP SWITCH (TEMP) 208-240/3/60 0140L02905-B 34 FACTORY WIRING C O STAT WH GR W G R RD Y1 YL R Y1 PK Y2 Y2 THERMOSTAT ++ G XFMR S1 LOW MED HIGH SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION 9 8 7 6 5 4 3 2 1 EBTDR C ALTERNATE MOTOR WIRING TERMINAL PLF R TABLE 2 TABLE 1 LPS 7 BLOWER INTERLOCK RELAY CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR FAN CAPACITOR EQUIPMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VALVE COIL TERMINAL BLOCK (24V SIGNAL) TRANSFORMER BLOWER CAPACITOR BIR C CCR CH CHS CM COMP DC DFT ECON EM FC GND HPS HVDR LPS LVDR LVJB PLF RVC TB1 TR BC NOTES: C T2 BK COMPONENT LEGEND L3 L2 SUPPLY VOLTAGE 208-240/3/60 ++ L1 T H E R M O S T A T T3 T2 T1 ALTERNATE MOTOR 6-WIRES SEE TABLE 1 RD RD YL BK RD CONTROL BOX LVJB YL PU RD GR WH BR OR BL BL BR PK WH Y PS2 OR RD GR PLF 2 3 6 9 2 5 8 1 4 7 PU RD C-RV HVDR PU OR 0 LVDR BR SEE NOTE 4 L1 T1 PU PU 0 PU C BK BK 3 BIR DC YL PU RD 2 BR DF1 L3 RD YL BK BL DF2 RD RD 2 0 8 2 4 0 / 3 / 6 0 ⚡ NC M2 YL/PK R PK BL T3 BK RD High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. BL COM BL BL BL ⚠ Warning BL 3 TR 24V RD NO R K1 XFMR-R XFMR-C K1 C SEE NOTE #2 SPEED M1 UP LPS YL/PK EBTDR 2 208 240 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BL C GR ++ G 1 BR RD SEE NOTE 8 BK BK G C BL C O OR O STAT TB1 SS-DSH3 Wiring Diagram — DSH060* THREE PHASE 208-230V/3/60HZ DIRECT DRIVE RD SEE NOTE 6 SEE NOTE 3 RD YL BL RD RD T2 L3 L2 L2 L1 T1 YL GND C DC C C R R RD CCR PU CNT PU OR 0 0 LVDR W GR WH BK Y HVDR R-PS1 DFT R-DFT DF2 DF1 RD 5 3 6 9 2 5 8 1 4 PU OR BR YL WH PU PU RD PU BR BK BK BK TB1 WH BR OR BL T H E R M O S T A T REPLACE JUMPER WITH BL/PK SMOKE/FIRE DETECTOR YL BL/PK CM COMP RVC L1 L2 COMPONENT LEGEND L3 C CCR CH CHS CM COMP DC DFT ECON EM GND HPS HVDR LPS LVDR LVJB PLF RVC RCCF SUPPLY VOLTAGE 208-240/1/60 T1 C T2 T2 COMP C T3 T3 C DF2 DF1 HVDR RCCF F CM SEE NOTE 6 TB1 TR RV NOTES: CH CHS 208-240V SEE NOTE 3 2 3 1 TR 24V RVC O-RV R O C-RV W ++ USE N.E.C. CLASS 2 WIRE DFT DFT2 DFT1 DC R-PS1 Y PS2 5. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY. 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION C CNT LPS JUNCTION P 4 L F 5 1 SEE NOTE 2 1 2 3 4 5 6 TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION EM C SWITCH (PRESS.) C OVERCURRENT PROT. DEVICE HPS FIELD GROUND FIELD SPLICE SWITCH (TEMP) IGNITER R W2 W1 Y2 Y1 THERMOSTAT ++ O G LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BL BR GR RD PK PU OR WH YL BLACK BLUE BROWN GREEN RED PINK PURPLE ORANGE WHITE YELLOW THERMOSTAT FIELD WIRING NO ECONOMIZER W G WH GR R RD R Y1 YL Y W G Y2 C BL O OR C O STAT TB1 W G WH GR W R RD R Y1 YL G Y Y2 C BL O OR TB1 C O STAT 2 STAGE COOLING PLF2 S2 LINE VOLTAGE WITH ECONOMIZER OPTION EQUIPMENT GROUND 9 8 7 6 5 4 3 2 1 S1 HPS FACTORY WIRING CONTACTOR COMPRESSOR CONTACTOR RELAY CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ECONOMIZER EVAPORATOR MOTOR EQUIPMENT GROUND HIGH PRESSURE SWITCH HIGH VOLTAGE DEFROST RELAY LOW PRESSURE SWITCH LOW VOLTAGE DEFROST RELAY LOW VOLTAGE JUNCTION BOX FEMALE PLUG / CONNECTOR REVERSING VALVE COIL RUN CAPACITOR FOR CONDENSER FAN TERMINAL BLOCK (24V SIGNAL) TRANSFORMER REVERSING VALVE 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM "3" AND "4" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED. 3. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 4. USE COPPER CONDUCTORS ONLY L EM G SS-DSH3 Y1 Y2 R G W1 W2 O C S2 S1 ++ GR R YL SEE NOTE 6 BL RD PK CONTROL BOX RD BK BL LVJB T3 T1 T2 DFT BK N RD BR RD BL T1 7 BL PU 12 3 4 5 EM C L G N C GR WH WH OR BL BR RD SEE NOTE 2 RD F PS2 TB1 1 C RCCF Y YL GR YL PU RD WH PLF 1 CH PLF 2 3 6 9 2 5 8 1 4 7 YL RD WH C-RV OR GR YL BR BK 0-RV L1 SEE NOTE 4 PU BR 2 0 8 BK 2 4 0 RD / 3 / 6 0 BK C BK BK BL BL L3 ⚡ YL 24V PK T3 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. YL/PK BK YL ⚠ Warning YL/PK BL BL BK Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. LPS 3 2 208 240 TR CHS RD BK BL ++ 1 C RD BK RD C SEE NOTE 5 www.daikinac.com 208-240/3/60 0140L05411-A W G WH GR R RD R Y1 YL Y1 Y2 PK Y2 W G C BL C O OR O STAT TB1 35 WIRING DIAGRAMS FOR MODELS WITH DDC CONTROLS For complete information and installation instructions for models with DDC controls, see manual DK-DDC-TGD-XXX 36 www.daikinac.com SS-DSH3 BL 46 GND COM GND VOUT DC GND STPT OFFSET TEMP VOUT DC GND 24 VAC OAT WH WH WH WH SS-DSH3 www.daikinac.com Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BL HPS C TB2 BL/ PK YL AG YL/ PK GR BPSW BK BK BL RD BL GR GR BR PU GR GND 24VAC AGND AGND AI8 AI7 AI6 AI5 AI4 AI3 AI2 AI1 BI8 BI7 BI6 BI5 BI3 BI4 BI2 BI1 BK ⚠ Warning DFT RD YL LDS CFS YL/PK RSS RD LPS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BL BK GR RD BL/PK PU PU BK PU PK - ALRM + RD 4 1 6 3 ECON 5 2 WH BK BR RD WH BK RD BL BK WH BK BK 208-240/3/60 SEE NOTE 2 RD YL PU 1 4 7 L1 L2 BK OR BL BK BK T1 T2 BK RD ⚡ GR C F BR RCCF BK BL YL CFC RD CC BL RD RD BK BR PU 208-240/3/60 CHS 0140L05811-A CM COMP BC BR EM BL 3 SPEED TB PU PU RVC SEE NOTES 7 & 8 BK HEATER PLF 2 5 8 RD BK BK BR 3 6 9 BK RD RD BL High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. GND GND + EXF - - AO4 + GR BK RD POWER SUPPLY GR BK RD BK RD HGRH AO2 WH WH BR OR BK PK RD GR YL PK AO3 AO1 COM3-8 COM3-8 RL8 RL6 RL7 RL4 RL5 RL3 RL1 RL2 COM2 COM1 YL SMK/EMG BC L1 DAT SEE NOTE 5 RD BL T1 T2 T3 T4 T5 CS PS ES XS DA BL 3 240 BL L2 RD RD 2 208 TR2 24V BL BL L3 BK TB1 24V BL 1 C RD BK T1 RD RD 3 240 BK PU L1 T2 24VAC RD 2 208 TR1 24V RD 1 C RD BK SEE NOTE 4 L2 T3 VOUT DC BL GND RD UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. T1 CO2 T2 SPCRH SPCTEMP OARH ING DIAGRAMS Wiring Diagram with DDC— DSH036/DSH048*** (208-230V/3/60) D*** DSH036/DSH048*** [208-230V/3/60] D*** 37 L1 38 BR EM 3 S P E ED BK CH DFT CFS LDS RSS LPS BPSW 1 2 DDC RL2 BI5 RL1 BI3 BI4 BI7 RL5 RL8 RL7 RL6 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. www.daikinac.com AO1 AO4 AO3 AO2 1 6 5 4 CCR1 + ALRM - + - EXF + HGRH - RVC CFC L3 ⚠ Warning SEE NOTE 5 BCC/BLS TR HEAT ER PLF SMK/EMG 24V 3 208/240/3/6 0 2 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GND 24VAC AGND AI8 AI7 AI6 AI5 AI4 COM3-8 AI3 AI2 AI1 BI8 RL4 RL3 COM2 COM1 BI6 L2 SEE NOTE 4 CC TR 3 BC CM T3 BI2 BI1 24V RD 208/240 /3/60 BC PU BL CC C RCCF F T2 SEE NOTE 6 COMP ECON 3 1 PLF 4 2 SPCRH SPC SENSOR OFFSET TEMP COM CO2 OARH OAT DAT HPS PU TB CHS CC T1 SEE NOTE 2 SUPPLY VOLT AGE 208-240/3 /60 COMPONENT LEGE ND DC GROUND FOR ANALOG SENSORS ("AG" ON TB2) 4 ANALOG OUTPUTS 8 ANALOG INPUTS ALARM BLOWER CONTACTOR BLOWER CONTACTOR COIL 8 BINARY INPUTS BLOWER LOW SPEED BLOWER PROVING SWITCH COMPRESSOR CONTACTOR COMPRESSOR CONTACTOR RELAY CONDENSOR FAN CONTACTOR CLOGGED FILTER SWITCH CRANKCASE HEATER CRANKCASE HEATER SWITCH CONDENSER MOTOR COMMON ("C" ON TB2) COMPRESSOR COM1 AND SMOKE DETECTOR DEFROST THERMOSTAT ECONOMIZER TB1-2 TR1-2 XS RD PU BC TABLE 2 RD BL BK LO W MED HIG H SPEE D TAPS SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION ALTERNATE MO T OR 6-W IRES SE E TAB LE 1 RD TABLE 1 AL TERNATE MOT OR W IRING TER MINAT IO N COLO R T2 (BC) RD BK TB BL TB PU PIN 1 (24V T R2) ⚡ SWITCH (TEMP) TERMINAL SWI TCH (PRESS.) JUNC TION OVERCURR ENT PROT. DEV ICE PLUG CONNECTION IGNITER FIELD SPLI CE FIELD GROUND SCHEMATI C SYMBOL High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. BK BL 3 SP E ED BR DIAGRAM1 EM HIGH VOLTAGE LOW VOLTAGE LINE VOLTAGE LOW V OLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING FACTORY WI RING EVAPORATOR MOTOR ECON COM3-8,BI1 AND SMOKE DETECTOR EXHAUST FAN EQUIPMENT GROUND HOT GAS REHEAT HIGH PRESSURE SWITCH LOAD SHEDDING LOW PRESSURE SWITCH OUTDOOR AIR TEMPERATURE OUTDOOR AIR RELATIVE HUMIDITY FEMALE PLUG / CONNECTOR HPS, LPS & SMOKE DETECTOR RUN CAPACITOR FOR CONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE COIL SUPPLY / DISCHARGE AIR TEMPERATURE SMOKE OR EMERGENCY SHUTDOWN SPACE TEMPERATURE SPACE RELATIVE HUMIDITY MOTOR SPEED TAPS 1-5 (DIRECT DRIVEN MOTOR ONLY) TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 24 VAC TRANSFORMER & SMOKE DETECTOR COMPONENT LEGE ND 0140L 05851-A 208-240/3 /60 WIRE CODE BK BLA CK BL BLUE BR BROWN GR GREEN OR ORANGE PK PI NK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIP YL/PK YELLOW WITH PINK STR IP EM ES EXF GND HGRH HPS LDS LPS OAT OARH PLF PS RCCF RL RSS RVC SAT/DAT SMK/EMG SPCTEMP SPCRH T1-T5 1. REPLA CEMENT WIRE MUST BE SAME SIZE AND TYPE IN SULATION AS ORIGINAL (AT LEAST 105°C) USE CO PPER CONDUCT OR ONLY . 2. USE COPP ER CONDUCT ORS ONLY ++ USE N.E.C. CLASS 2 W IRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMO VE MALE PL UG AND ATT ACH FEMALE PL UG TO THE ECONOMIZER ACCESS ORY. 4. FOR 208 VOLT T RANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO T ERMINAL 2 ON TRANSFORMER. 5. REMO VE JUMPER IF SMOKE DETECTOR OR EMERGENCY SHUTDOWN DEVI CE IS INSTALLED. 6. CRANKCASE HEAT ER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 7. TO CHANGE EVAP M OTOR SPE ED MOVE INTERCHANGE THE RED WIRE ON T2 OF THE BLOWER CONTACTOR WITH EITHER THE BLUE OR BK W IRE ON TB. SEE T ABLE 2. 8. FOR ALTE RNATE M OTOR WIRING SEE DIAGRAM 1. NOTES: AO AI ALRM BC BCC BI BLS BPSW CC CCR CFC CFS CH CHS CM COM COMP CS DFT ECON AGND UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. RING DIAGRAMS Wiring Diagram with DDC — DSH036/DSH048*** (208-230V/3/60)D*** DSH036/DSH048*** [208-230V/3/60] D*** SS-DSH3 RD 3 240 COM 24VAC GND GND VOUT DC GND STPT OFFSET TEMP GND VOUT DC 24 VAC OAT DAT WH WH WH WH WH BK BR PU YL SS-DSH3 www.daikinac.com Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BL C TB2 BL/ PK YL AG YL/ PK GR DFT BL BL RD BL GR GR BR PU GND 24VAC AGND AGND AI8 AI7 AI6 AI5 AI4 AI3 AI2 AI1 BI8 BI7 BI6 BI5 BI3 BI4 BI2 BI1 WH BK GR RL8 RL6 RL7 RL4 RL5 RL3 RL1 RL2 COM2 COM1 GND GND AO4 RD 4 1 6 3 ECON 5 2 WH BK BR BK BL BK RD WH BK BR WH 208-240/3/60 SEE NOTE 2 RD 9 2 5 8 RD 1 4 7 L2 L1 C BL BK BK BK OR T1 BL T2 CFC PU BK RD ⚡ RVC RD BK BL 0140L05812-A CHS CM COMP RD BK BR PU RD C L G N EM T1 T2 T3 T4 T5 PU WH BR YL OR 208-240/3/60 GR C F BR RCCF BK YL BK RD YL BL BL SEE NOTE 7 RD CC HEATER PLF 3 6 BR BK RD BK RD TB High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. - RD WH BK RD POWER SUPPLY BK RD BK RD SMK/EMG ALRM + + EXF - - HGRH + PK AO3 WH WH BR OR BK PK RD GR YL YL AO2 AO1 COM3-8 COM3-8 ⚠ Warning BK RD YL GR PU PK PU BK LDS CFS YL/PK RSS RD LPS BK BPSW Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BL BK GR RD BL/PK HPS PU T1 T2 T3 T4 T5 CS PS ES XS DA OR SEE NOTE 5 TB1 24V RD BR BK L1 RD 3 240 BL L2 RD 2 208 TR2 24V BK RD RD RD BL 1 C BL RD L3 VOUT DC BL 2 208 TR1 24V RD GND BK T1 BL BL 1 C RD SEE NOTE 4 DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. T2 CO2 T3 SPCRH SPCTEMP OARH NG DIAGRAMS Wiring Diagram with DDC — DSH060*** (208-230V/3/60) D*** DSH060*** [208-230V/3/60] D*** 39 L1 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 40 www.daikinac.com COM OFFSET SENSOR C EM L G N DFT CFS LDS RSS LPS BPSW 1 2 RL2 DDC RL8 RL7 RL6 RL5 RL4 RL3 AO1 AO4 AO3 AO2 1 6 4 5 TR 3 HEATER PLF SMK/EMG 24V 2 TB1 - ALRM + + - EXF - T5 EM T3 T2 T1 T4 CCR1 + CC L3 ⚠ Warning TB1 C SEE NOTE 5 HGRH RVC CFC 208/240/3 /60 T3 L2 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GND 24VAC AGND AI8 AI7 AI6 AI5 AI4 COM3-8 AI3 AI2 AI1 BI8 BI7 BI6 BI5 RL1 BI3 BI4 COM2 COM1 TR 3 SEE NOTE 4 CM BI2 BI1 24V T1 T2 T3 T4 T5 C CH 208/ 240/3/60 ECON 3 1 PLF 4 2 SPCRH SPC TEMP CO2 OARH OAT DAT HPS TB H SEE NOTE 6 F COMP RCC F CHS CFC T1 CC T1 SEE NOTE 2 SUP PLY VOLTAGE 208-240/3/60 T2 CC TB1-2 TR1-2 XS ⚡ SWITCH (TEMP) TERMIN AL SWITCH (PR ESS.) JUNCTION OVERCUR RENT PROT. DEVICE PLUG CONNECTION IGNITER FIELD SPLICE FIELD GROUND SCHEMA TIC SYMBO L High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SEE UN IT RATING PLATE FOR TYPE AND SIZE OF OVER C URRENT PROTECTION HIGH VOLTAGE LOW VOLTAGE LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRIN G FACTORY WIRIN G EVAPORATOR MOTOR ECON COM3-8,BI1 AND SMOKE DETECTOR EXHAUST FAN EQUIPMENT GROUND HOT GAS REHEAT HIGH PRESSURE SWITCH LOAD SHEDDING LOW PRESSURE SWITCH OUTDOOR AIR TEMPERATURE OUTDOOR AIR RELATIVE HUMIDITY FEMALE PLUG / CONNECTOR HPS, LPS & SMOKE DETECTOR RUN CAPACITOR FOR CONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE COIL SUPPLY / DISCHARGE AIR TEMPERATURE SMOKE OR EMERGENCY SHUTDOWN SPACE TEMPERATURE SPACE RELATIVE HUMIDITY MOTOR SPEED TAPS 1-5 (DIRECT DRIVEN MOTOR ONLY) TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 24 VAC TRANSFORMER & SMOKE DETECTOR COMPONEN T LEGEND 0140L05852 -A 208-240/3/60 WIRE C ODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PUR PLE RD RED WH WHI TE YL YELLOW BL/PK BLUE WITH PINK STRIPE YL/PK YELLOW WI TH PINK STRIPE EM ES EXF GND HGRH HPS LDS LPS OAT OARH PLF PS RCCF RL RSS RVC SAT/DAT SMK/EMG SPCTEMP SPCRH T1-T5 1. REPLACEME NT WIRE MU ST BE SAME SIZE A ND TYPE INSULATION AS ORIGINAL (AT LEAS T 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE R ETURN AIR COMPARTMEN T. REMOVE M ALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACC ESSORY. 4. FOR 208 VO LT TRANS FORMER OPERATION MOVE BLACK WIRE F ROM TERMIN AL 3 TO TERMINAL 2 ON TRANS FORMER. 5. REMOVE JUMPER IF SMOKE DETECTOR OR EMERGENCY SHUTDOWN DEVI CE IS INSTALLED. 6. CRANK CASE H EATER AND CRAN KCASE HEATER SWITCH FA CTORY EQUIPPED W HEN REQUIRED. 7. FOR DIFFE RENT THAN FA CTORY SPEED TAP. CH ANGE COOLING SPEED AT MOTOR T4 AND T5 TERMINALS. CHA NGE HEATING SPEED AT MOTOR T1, T2 AND T3. SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REP RESE NTATIVE BUT ACTUAL FACTORY SETTINGS MAY BE DIFFE RENT BASED ON THE HE ATING VALUE OF THE UN IT. COOLING SPEED ( GREEN AND BROWN) T3 - LOW SPEED T4 - HIGH SPEED HEATING SPEED (WHI TE) T1 - LOW SPEED T2 - MED SPEED T5 - HIGH SPEED NOTES: COMPONENT LEGEND DC GROUND FOR ANALOG SENSORS ("AG" ON TB2) 4 ANALOG OUTPUTS AO 8 ANALOG INPUTS AI ALARM ALRM 8 BINARY INPUTS BI BLOWER LOW SPEED BLS BPSW BLOWER PROVING SWITCH COMPRESSOR CONTACTOR CC COMPRESSOR CONTACTOR RELAY CCR CONDENSOR FAN CF CLOGGED FILTER SWITCH CFS CRANKCASE HEATER CH CRANKCASE HEATER SWITCH CHS CONDENSER MOTOR CM COMMON ("C" ON TB2) COM COMP COMPRESSOR COM1 AND SMOKE DETECTOR CS DEFROST THERMOSTAT DFT ECON ECONOMIZER AGND DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring Diagram with DDC — DSH060*** (208-230V/3/60) D*** NG DIAGRAMS DSH060*** [208-230V/3/60] D*** SS-DSH3 BL 52 GND COM GND VOUT DC GND STPT OFFSET TEMP VOUT DC GND 24 VAC OAT SS-DSH3 www.daikinac.com Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BL BK GR BL C TB2 AG Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WH WH YL YL/ PK GR BK BL RD BL GR GR BR PU GR GND 24VAC AGND AGND AI8 AI7 AI6 AI5 AI4 AI3 AI2 AI1 BI8 BI7 BI6 BI5 BI3 BI4 BI2 ⚠ Warning DFT RD YL BK LDS CFS YL/PK RSS RD LPS BI1 - ALRM + RD 4 1 3 6 ECON 5 2 WH BK BR RD WH BK RD BL WH BK BK BK 9 2 5 BC BL PU L2 1 4 7 L1 C BK OR BL BK BK T1 T2 ⚡ BK RD GR C F BR RCCF BK CFC YL YL RD CC BL BK HEATER PLF 3 6 BR 8 RD BK BK WH BK RD RD High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. BK GND GND + EXF - - AO4 + HGRH AO3 WH PK RD WH BR OR BK GR YL AO2 AO1 COM3-8 COM3-8 RL8 RL4 RL5 RL6 RL7 RL3 RL1 RL2 COM2 COM1 PK OR L1 WH WH BL/ PK BK BPSW YL 208-240/3/60 SEE NOTE 2 RD POWER SUPPLY GR BK RD BK RD GR BK RD OR L2 RD BL/PK HPS PU PU PK PU BK SMK/EMG BL L3 DAT SEE NOTE 5 RD BL T1 T2 T3 T4 T5 CS PS ES XS DA BL 3 240 T1 RD RD 2 208 TR2 24V BL T2 C RD TB1 24V BL 1 C BL L1 T3 24VAC RD RD 3 240 BK L2 RD 2 208 TR1 24V BK L3 C BL 1 C RD BL RD BK T1 VOUT DC GND RD SEE NOTE 4 DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. T2 CO2 T3 SPCRH SPCTEMP OARH 0140L05015-B CM CHS 208-240/3/60 RVC RD RD BK BR PU COMP EM NG DIAGRAMS Wiring Diagram with DDC— DSH036 / DSH048 / DSH060*** (208-230V, 460V, 575V / 3/ 60) B*** DSH036/DSH048/DSH060*** [208-230V/3/60] B*** 41 BL www.daikinac.com GND COM GND VOUT DC GND STPT OFFSET TEMP GND VOUT DC BL BK GR RD BL HPS C TB2 BL/ PK YL PU AG YL/ PK Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WH WH OAT 24 VAC WH WH RD BL SEE NOTE 5 3 240 BK BL RD BL GR GR BR PU BK RL7 GND 24VAC AGND AGND AI8 AI7 AI6 AI5 AI4 AI3 AI2 AI1 - ALRM + RD 4 1 6 3 ECON 5 2 WH BK BR RD WH BK BL BK RD WH BK BK POWER SUPPLY RD 208-240/1/60 SEE NOTE 2 GR BK RD BR 2 5 8 RD YL 1 4 7 L1 L2 BK OR BL BK BK T1 T2 CFC BK BK ⚡ GR RD 0140L05808-A CM CHS BR 208-240/1/60 RVC RD RD BK BR PU PU PU RCCF COMP BC PU BR EM TB 3 SPEED BL H C F YL SEE NOTES 7 & 8 RD BK BL BL BL RD CC HEATER PLF 3 6 9 BK BK RD BK BC High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. GND GND + EXF - - AO4 GR BK RD BK RD HGRH + PK AO3 WH WH BR OR BK PK RD GR YL YL SMK/EMG AO2 AO1 COM3-8 COM3-8 RL8 BI8 BI7 RL6 RL5 RL4 RL3 RL1 RL2 COM2 COM1 BI6 BI5 BI4 BI3 BI2 BI1 ⚠ Warning GR DFT RD YL GR PU PK PU BK BK LDS CFS YL/PK RSS RD LPS BK BPSW T1 T2 T3 T4 T5 CS PS ES XS DA BL BL/PK RD 2 208 TR2 24V BL L1 RD TB1 24V BL 1 C BL L2 DAT RD RD 3 240 RD T1 24VAC RD RD 2 208 TR1 24V BK BK BL L1 BL 1 C RD BK L2 T2 VOUT DC GND RD PU T1 SPCRH SPCTEMP OARH 42 T2 CO2 SEE NOTE 4 WIRING DIAGRAM WITH DDC – DSH036/048***(208-230V/1/60)D*** SS-DSH3 L1 SS-DSH3 www.daikinac.com C BR EM 3 SPEED BK ECON 3 1 PLF 4 2 SPCRH COM OFFSET 1 CCR1 + ⚠ Warning - ALRM + + - EXF - HGRH RVC CFC L2 SEE NOTE 5 BCC/BLS TR 6 54 HEATER PLF SMK/EMG 24V 3 208/240/1/60 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GND AO4 AO3 AO2 AO1 RL8 RL7 RL6 RL5 RL4 RL3 COM3-8 24VAC AGND AI8 AI7 AI6 AI5 CO2 SENSOR AI4 OARH AI3 AI2 BI8 BI7 BI6 OAT SPC TEMP DDC RL2 COM2 RL1 BI3 BI4 BI5 COM1 BI1 TR 3 2 SEE NOTE 4 BC CM BI2 AI1 DFT CFS LDS RSS LPS 1 2 24V RD 208/240/1/60 BPSW BC PU BL CH DAT HPS PU TB CHS H SEE NOTE 6 F COMP RCCF CC T1 SEE NOTE 2 SUPPLY VOLTAGE 208-240/1/60 T2 CC TB1-2 TR1-2 XS PU RD BC TABLE 2 SPEED TAPS RD LOW BL MED BK HIGH SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION ALTERNATE MOTOR 6-WIRES SEE TABLE 1 RD TABLE 1 ALTERNATE MOTOR WIRING COLOR TERMINATION RD T2 (BC) BK TB BL TB PU PIN 1 (24V TR2) High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. BK BL EM 3 SPEED BR DIAGRAM1 LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE FACTORY WIRING EVAPORATOR MOTOR ECON COM3-8,BI1 AND SMOKE DETECTOR EXHAUST FAN EQUIPMENT GROUND HOT GAS REHEAT HIGH PRESSURE SWITCH LOAD SHEDDING LOW PRESSURE SWITCH OUTDOOR AIR TEMPERATURE OUTDOOR AIR RELATIVE HUMIDITY FEMALE PLUG / CONNECTOR HPS, LPS & SMOKE DETECTOR RUN CAPACITOR FOR CONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE COIL SUPPLY / DISCHARGE AIR TEMPERATURE SMOKE OR EMERGENCY SHUTDOWN SPACE TEMPERATURE SPACE RELATIVE HUMIDITY MOTOR SPEED TAPS 1-5 (DIRECT DRIVEN MOTOR ONLY) TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 24 VAC TRANSFORMER & SMOKE DETECTOR COMPONENT LEGEND ⚡ SWITCH (TEMP) TERMINAL SWITCH (PRESS.) JUNCTION OVERCURRENT PROT. DEVICE PLUG CONNECTION IGNITER FIELD SPLICE FIELD GROUND SCHEMATIC SYMBOL 0140L05848-A 208-240/1/60 WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIPE YL/PK YELLOW WITH PINK STRIPE EM ES EXF GND HGRH HPS LDS LPS OAT OARH PLF PS RCCF RL RSS RVC SAT/DAT SMK/EMG SPCTEMP SPCRH T1-T5 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. 4. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 5. REMOVE JUMPER IF SMOKE DETECTOR OR EMERGENCY SHUTDOWN DEVICE IS INSTALLED. 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 7. TO CHANGE EVAP MOTOR SPEED MOVE INTERCHANGE THE RED WIRE ON T2 OF THE BLOWER CONTACTOR WITH EITHER THE BLUE OR BK WIRE ON TB. SEE TABLE 2. 8. FOR ALTERNATE MOTOR WIRING SEE DIAGRAM 1. NOTES: COMPONENT LEGEND DC GROUND FOR ANALOG SENSORS ("AG" ON TB2) 4 ANALOG OUTPUTS AO 8 ANALOG INPUTS AI ALRM ALARM BLOWER CONTACTOR BC BLOWER CONTACTOR COIL BCC 8 BINARY INPUTS BI BLOWER LOW SPEED BLS BPSW BLOWER PROVING SWITCH COMPRESSOR CONTACTOR CC COMPRESSOR CONTACTOR RELAY CCR CONDENSOR FAN CF CONDENSOR FAN CONTACTOR CFC CLOGGED FILTER SWITCH CFS CRANKCASE HEATER CH CRANKCASE HEATER SWITCH CHS CONDENSER MOTOR CM COMMON ("C" ON TB2) COM COMP COMPRESSOR COM1 AND SMOKE DETECTOR CS DEFROST THERMOSTAT DFT ECON ECONOMIZER AGND WIRING DIAGRAM WITH DDC – DSH036/048***(208-230V/1/60)D*** 43 www.daikinac.com COM 24VAC GND VOUT DC 3 24 VAC BR PU RD BL BK GR RD BL HPS C TB2 BL/ PK YL PU AG YL/ PK Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GND VOUT DC GND STPT OFFSET TEMP GND VOUT DC TB1 WH BL YL DFT LDS CFS BK RD YL BK BL RD BL GR GR BR PU GR PU PK PU BK WH GND 24VAC AGND AGND AI8 AI7 AI6 AI5 AI4 AI3 AI2 AI1 BI8 HGRH - ALRM + RD 4 1 3 ECON 5 6 2 WH BK BR RD WH BK BL BK RD BR WH WH BK BK POWER SUPPLY 208-240/1/60 SEE NOTE 2 BK RD BK RD BK RD 2 5 8 YL CC L2 1 4 7 L1 C BR RD BK BK HEATER PLF 3 6 9 BK RD RD TB BK OR BL BK BK T1 T2 CFC BL BL High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. GND GND + EXF - - AO4 + PK AO3 WH WH BR OR BK PK RD GR YL YL SMK/EMG AO2 AO1 COM3-8 COM3-8 RL8 BI7 RL6 RL5 RL4 RL3 RL1 RL2 COM2 COM1 BR RL7 BK GR BI6 BI5 BI4 BI3 BI2 BI1 ⚠ Warning GR BPSW YL/PK RSS RD LPS SEE NOTE 5 T1 T2 T3 T4 T5 CS PS ES XS DA OR 3 240 BL/PK BL 24V RD WH WH 2 208 TR2 24V BK RD OAT BL 1 C WH WH RD RD 240 DAT RD RD 2 208 TR1 24V BK L1 BK 1 C RD BL BK L2 BL BL GND RD RD T1 SPCRH SPCTEMP OARH 44 T2 CO2 SEE NOTE 4 ⚡ BK PU GR BK RD YL BR CHS RCCF 0140L05813-A CM PU BR H C F RD COMP BL C L G N EM T1 T2 T3 T4 T5 208-240/1/60 RVC RD RD BK BR PU YL YL OR SEE NOTE 7 BK RD WH WIRING DIAGRAM WITH DDC – DSH060***(208-230V/1/60)D*** SS-DSH3 L1 SS-DSH3 www.daikinac.com C EM L G N COM OFFSET SENSOR GND 24VAC AGND AI8 AI7 AO1 AO4 AO3 AO2 COM3-8 RL8 RL7 RL6 RL5 RL4 RL3 1 6 54 HEATER PLF SMK/EMG TR 3 + TB1 L2 ⚠ Warning - ALRM + + - EXF - HGRH RVC T5 EM C T3 T2 T1 T4 TB1 SEE NOTE 5 CCR1 CFC 208/240/1/60 24V 2 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. ECON 3 1 PLF 4 2 SPCRH SPC TEMP AI5 CO2 AI6 AI4 OARH AI3 AI2 OAT BI8 BI7 BI6 BI5 RL2 COM2 RL1 BI3 BI4 TR 3 SEE NOTE 4 COM1 DDC CM BI2 BI1 24V 2 AI1 DFT CFS LDS RSS LPS BPSW 1 208/240/1/60 T1 T2 T3 T4 T5 C CH DAT HPS H SEE NOTE 6 F COMP RCCF CHS TB CFC T1 CC T1 SEE NOTE 2 SUPPLY VOLTAGE 208-240/1/60 T2 CC TB1-2 TR1-2 XS High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION HIGH VOLTAGE LOW VOLTAGE LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE OPTIONAL LOW VOLTAGE FIELD WIRING FACTORY WIRING EVAPORATOR MOTOR ECON COM3-8,BI1 AND SMOKE DETECTOR EXHAUST FAN EQUIPMENT GROUND HOT GAS REHEAT HIGH PRESSURE SWITCH LOAD SHEDDING LOW PRESSURE SWITCH OUTDOOR AIR TEMPERATURE OUTDOOR AIR RELATIVE HUMIDITY FEMALE PLUG / CONNECTOR HPS, LPS & SMOKE DETECTOR RUN CAPACITOR FOR CONDENSER FAN RELAY REMOTE START STOP REVERSING VALVE COIL SUPPLY / DISCHARGE AIR TEMPERATURE SMOKE OR EMERGENCY SHUTDOWN SPACE TEMPERATURE SPACE RELATIVE HUMIDITY MOTOR SPEED TAPS 1-5 (DIRECT DRIVEN MOTOR ONLY) TERMINAL BLOCK (24V SIGNAL) TRANSFORMER 24 VAC TRANSFORMER & SMOKE DETECTOR COMPONENT LEGEND ⚡ SWITCH (TEMP) TERMINAL SWITCH (PRESS.) JUNCTION OVERCURRENT PROT. DEVICE PLUG CONNECTION IGNITER FIELD SPLICE FIELD GROUND SCHEMATIC SYMBOL 0140L05853-A 208-240/1/60 WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW BL/PK BLUE WITH PINK STRIPE YL/PK YELLOW WITH PINK STRIPE EM ES EXF GND HGRH HPS LDS LPS OAT OARH PLF PS RCCF RL RSS RVC SAT/DAT SMK/EMG SPCTEMP SPCRH T1-T5 1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY. 2. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE 3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY. 4. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. 5. REMOVE JUMPER IF SMOKE DETECTOR OR EMERGENCY SHUTDOWN DEVICE IS INSTALLED. 6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY EQUIPPED WHEN REQUIRED. 7. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING SPEED AT MOTOR T4 AND T5 TERMINALS. CHANGE HEATING SPEED AT MOTOR T1, T2 AND T3. SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REPRESENTATIVE BUT ACTUAL FACTORY SETTINGS MAY BE DIFFERENT BASED ON THE HEATING VALUE OF THE UNIT. COOLING SPEED (GREEN AND BROWN) T3 - LOW SPEED T4 - HIGH SPEED HEATING SPEED (WHITE) T1 - LOW SPEED T2 - MED SPEED T5 - HIGH SPEED NOTES: COMPONENT LEGEND DC GROUND FOR ANALOG SENSORS ("AG" ON TB2) 4 ANALOG OUTPUTS AO 8 ANALOG INPUTS AI ALRM ALARM 8 BINARY INPUTS BI BLOWER LOW SPEED BLS BPSW BLOWER PROVING SWITCH COMPRESSOR CONTACTOR CC COMPRESSOR CONTACTOR RELAY CCR CONDENSOR FAN CF CONDENSOR FAN CONTACTOR CFC CLOGGED FILTER SWITCH CFS CRANKCASE HEATER CH CRANKCASE HEATER SWITCH CHS CONDENSER MOTOR CM COMMON ON TB2) ("C" COM COMP COMPRESSOR COM1 AND SMOKE DETECTOR CS DEFROST THERMOSTAT DFT ECON ECONOMIZER AGND WIRING DIAGRAM WITH DDC – DSH060***(208-230V/1/60)D*** 45 Accessories Daikin Master Item # Description Fits Model Sizes FieldInstalled FactoryInstalled Operating Weight (lbs) Curb 14CURB3672B 14” Roof Curb 3-5 Tons √ 86 18CURB3672B 18” Roof Curb 3-5 Tons √ 100 24CURB3672B 24” Roof Curb 3-5 Tons √ 128 GHRC-3672 Hurricane Restraint Clips 3-5 Tons √ 2 Ultra Low-Leak Economizer & Power Exhaust 1 10-365-09C Ultra Low-Leak Downflow Economizer w/ Dry Bulb 3-5 Tons √ 10-366-09C Ultra Low-Leak Downflow Economizer w/ Enthalpy 3-5 Tons √ 71 10-395-09 Ultra Low-Leak Horizontal Economizer w/ Dry Bulb 3-5 Tons √ 71 10-396-09 Ultra Low-Leak Horizontal Economizer w/ Enthalpy 3-5 Tons √ 71 10-455-09*-23 Centrifugal Power Exhaust 230v 3-5 Tons √ 55 10-455-09*-33 Centrifugal Power Exhaust 460v 3-5 Tons √ 55 10-455-09*-43 Centrifugal Power Exhaust 575v 3-5 Tons √ 55 10-457-09xA-23 Modulating Power Exhaust 208-230v 3-5 Tons √ 55 10-457-09xA-33 Modulating Power Exhaust 460v 3-5 Tons √ 55 10-465-09-21 Prop Power Exhaust 230v 3-5 Tons √ 55 10-465-09-31 Prop Power Exhaust 460v 3-5 Tons √ 55 10-465-09-41 Prop Power Exhaust 575v 3-5 Tons √ 55 √ 71 Low-Leak Economizer & Power Exhaust 2 DDNECNJ3672C Low-Leak Downflow Economizer 3-5 Tons √ √ 82 DPE36722 Downflow Power Exhaust (208/230 Volt) 3-5 Tons √ 55 DPE36724 Downflow Power Exhaust (460 Volt) 3-5 Tons √ 55 DPE36727 Downflow Power Exhaust (575v) 3-5 Tons √ 55 DHZECNJ3672 Horizontal Economizer 3-5 Tons √ 70 DHPE36722 Horizontal Power Exhaust (208/230 Volt) 3-5 Tons √ 55 DHPE36724 Horizontal Power Exhaust (460 Volt) 3-5 Tons √ 55 DHPE36727 Horizontal Power Exhaust (575 Volt) 3-5 Tons √ 55 Downflow Accessories D25FD3672 25% Manual Fresh Air Damper 3-5 Tons √ 12 D25MFD3672 25% Motorized Fresh Air Damper 3-5 Tons √ 16 DDNBBS3672 Burglar Bar Sleeves with Supply & Return 3-5 Tons √ 30 DDNECNJ3672NR Downflow Economizer2 w/o Barometric Relief 3-5 Tons √ 77 DDNSQRD3616 Downflow Square-to-Round Adapter (16” Round) 3 tons √ 45 4-5 tons √ 35 3-5 Tons √ 15 DDNSQRD487218 Downflow Square-to-Round Adapter (18” Round) Horizontal Accessories DBRD3672 Barometric Relief Damper Concentrics CDK36 Concentric Duct Kit 3 Ton √ 27 CDK36515 Flush Mount Concentric Duct Kit w/ Filter 3 Ton √ 28 CDK36530 Step Down Concentric Duct Kit 3 Ton √ 27 CDK36535 Step Down Concentric Duct Kit w/ Filter 3 Ton √ 28 46 www.daikinac.com SS-DSH3 Accessories (cont.) Daikin Master Item # Description Fits Model Sizes FieldInstalled FactoryInstalled Operating Weight (lbs) CDK4872 Concentric Duct Kit 4-5 Ton √ 27 CDK4872515 Flush Mount Concentric Duct Kit w/ Filter 4-5 Ton √ 28 CDK4872530 Step Down Concentric Duct Kit 4-5 Ton √ 27 CDK4872535 Step Down Concentric Duct Kit w/ Filter 4-5 Ton √ 28 DDC Accessories 3 DDC communicating controller (built-in BACnet® MS/TP) includes Standard Room Sensor to be installed in field 3-5 Tons √ 2 10366D09C DDC Ultra Low-Leak Downflow Economizer 3-5 Tons √ √ 71 10366D09 DDC Ultra Low-Leak Horizontal Economizer 3-5 Tons √ 71 10465DDC Power Exhaust kit used with DDC Ultra Low-Leak Economizer 3-5 tons √ 1 DLAKT01 Low-Ambient 3-5 Tons √ LONKT01 LonWorks® card 3-5 Tons √ 3PMK01 Phase Monitor (3-Phase Only) 3-5 Tons √ DFSKT01 Dirty Filter Switch 3-5 Tons √ √ 2 1 √ 2 1 1 phase 208-230V Electric Heat Kits SPKT01 Single Point Wiring Kit 1phase Heat Kits 3-5 Tons √ √ 3 EHK1-10 10kw 208-230v 1ph Electric Heat Kit 3-5 Tons √ √ 21 EHK1-15 15kw 208-230v 1ph Electric Heat Kit 3-5 Tons √ √ 21 EHK1-18 18kw 208-230v 1ph Electric Heat Kit 4 tons √ √ 21 EHK1-20 20kw 208-230v 1ph Electric Heat Kit 5 tons √ √ 21 3 phase 208-230V Electric Heat Kits SPKT02 Single Point Wiring Kit 3phase Heat Kits 3-5 Tons √ √ 3 EHK3-10 10kw 208-230 3ph Electric Heat Kit 3-5 Tons √ √ 21 EHK3-15 15kw 208-230 3ph Electric Heat Kit 3-5 Tons √ √ 21 EHK3-18 18kw 208-230 3ph Electric Heat Kit 4 tons √ √ 21 EHK3-20 20kw 208-230 3ph Electric Heat Kit 5 tons √ √ 21 3 phase 460V Electric Heat Kits EHK4-10 10kw 460v 3ph Electric Heat Kit 3-5 Tons √ √ 21 EHK4-15 15kw 460v 3ph Electric Heat Kit 3-5 Tons √ √ 21 EHK4-18 18kw 460v 3ph Electric Heat Kit 4 tons √ √ 21 EHK4-20 20kw 460v 3ph Electric Heat Kit 5 tons √ √ 21 3 phase 575V Electric Heat Kits EHK7-10 10kw 575v 3ph Electric Heat Kit 3-5 Tons √ √ 21 EHK7-15 15kw 575v 3ph Electric Heat Kit 3-5 Tons √ √ 21 EHK7-18 18kw 575v 3ph Electric Heat Kit 4 tons √ √ 21 EHK7-20 20kw 575v 3ph Electric Heat Kit 5 tons √ √ 21 High-Static Kits4 HSKTS036 High Static Kit - 230v & 460v DS*, 3 Ton √ √ 2 HSKTS048 High Static Kit - 230v & 460v DS*, 4 Ton √ √ 38 HSKTS060 High Static Kit - 230v & 460v DS*, 5 Ton √ √ 38 SS-DSH3 www.daikinac.com 47 Accessories (cont.) Daikin Master Item # Description Fits Model Sizes FieldInstalled FactoryInstalled Operating Weight (lbs) HSKTS036-7 High Static Kit - 575v DS*, 3 Ton √ √ 2 HSKTS048-7 High Static Kit - 575v DS*, 4 Ton √ √ 5 HSKTS060-7 High Static Kit - 575v DS*, 5 Ton √ √ 38 Crankcase Heater Kits 0163R00002S 40W 230V 3 tons √ 1 0163R00031S 40W 460V 3 tons √ 1 0163R00032S 40W 575V 3 tons √ 1 0130L00017S 70W 230V 4 - 5 tons √ 1 0130L00018S 70W 460V 4 - 5 tons √ 1 0130L00019S 70W 575V 4 - 5 tons √ 1 High Efficiency Filters 0160L00203 High Efficiency MERV 13 Air Filter Nom. Size: 24x24x2; (Order Qty 1) 3 tons √ 2 0160L00204 High Efficiency MERV 13 Air Filter Nom. Size: 14x20x2; (Order Qty 4) 4 tons √ 4 0160L00205 High Efficiency MERV 13 Air Filter Nom. Size: 16x20x2; (Order Qty 4) 5 tons √ 4 Condenser Coil Hail Guard 3-5 tons √ 19 Convenience Outlet: Non Powered 3-5 tons √ 2 Convenience Outlet: Powered 3-5 tons √ 42 Misc Accessories HAILGD03D Disconnect Switch 3-5 tons √ 5 LAKT11 Low Ambient Kit, 208-230V - non-DDC 3-5 tons √ √ 14 LAKT13 Low Ambient Kit, 460V - non-DDC 3-5 tons √ √ 14 LAKT14 Low Ambient Kit, 575V - non-DDC 3-5 tons √ √ 14 3PMNDK01 Phase Monitor - Non DDC 3-5 Ton √ √ 2 Smoke Detector (supply and/or return air) 3-5 Ton √ 11 Hinged Panels 3-5 Ton √ 10 FSK01A Freeze Stat Kit 3-5 Ton √ 1 IRKT-01 Isolation Relay Kit 3-5 Ton √ 2 Use Economizer & Power Exhaust listed within Ultra Low-Leak section 2 Use Economizer & Power Exhaust listed within Low-Leak section 3 For a full list of DDC accessories, pleas e refer to DDC Controller Technical Guide manual (DK-DDC-TGD-01B) 4 HSKT High-Static Kits are for use with standard single-speed belt-drive units only. Note: Where multiple variations are available, the heaviest combination is listed. 1 Our continuing commitment to quality products may mean a change in specifications without notice. © 2017 • Houston, Texas • Printed in the USA. 48 www.daikinac.com SS-DSH3