Preview only show first 10 pages with watermark. For full document please download

Dsxc16 S A C

   EMBED


Share

Transcript

DSXC16 Split System Air Conditioner Up to 16 SEER Cooling Capacity: 24,000 - 57,000 BTU/h Contents Nomenclature........................................ 2 Product Specifications........................... 3 Expanded Cooling Data......................... 4 AHRI Ratings......................................... 20 Dimensions.......................................... 30 Wiring Diagram.................................... 31 Accessories........................................... 32 Standard Features Cabinet Features • R-410A chlorine-free refrigerant • Two-Stage Copeland® UltraTech™ scroll compressor • High-density foam compressor sound blanket • ComfortNet™ Communications System compatible • Expanded ComfortAlert™ diagnostics • Set-up capable with 2 lowvoltage wires to outdoor unit • Diagnostic indicator lights and storage of 6 fault codes • Color-coded terminal strip for non-communicating set-up • High- and low-pressure switches • Factory-installed filter drier • Coil and ambient temperature sensors • Two-speed, quiet condenser fan motor • AHRI Certified; ETL Listed • • • • • SS-DSXC16 www.goodmanmfg.com Wire fan discharge grille Steel louver coil guard Baked-on powder paint finish Top and side maintenance access Single-panel access to controls with space provided for field-installed accessories • When properly anchored, meets 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.) * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. 3/14 Supersedes 2/14 Product Specifications Nomenclature D S X C 16 036 1 A A 1 2 3 4 5,6 7,8,9 10 11 12 Brand D Goodman® Brand Engineering * Minor Revision Product Category S Split System Engineering * Major Revision Unit Type C Condenser R-22 X Condenser R-410A H Heat Pump R-22 Z Heat Pump R-410A Communication Feature C ComfortNet 4-wire communications ready Efficiency 13 13 SEER 14 14 SEER Electrical 208/230 V, 1 Phase, 60 Hz 220/240 V, 1 Phase, 50 Hz 208/230 V, 3 Phase, 60 Hz 460 V, 3 Phase, 60 Hz 380/415 V, 3 Phase, 50 Hz 1 2 3 4 5 018 024 030 036 042 16 16 SEER 18 18 SEER 1½ Tons 2 Tons 2½ Tons 3 Tons 3½ Tons Nominal Capacity 048 4 Tons 060 5 Tons 090 7½ tons 120 10 Tons * Neither used for order entry or inventory management. 2 www.goodmanmfg.com SS-DSXC16 Product Specifications Specifications DSXC16 0241AA/B DSXC16 0241AC DSXC16 0361AA/B DSXC16 0361AC DSXC16 0481B* DSXC16 0601B* 24,000 24,000 36,000 36,000 48,000 60,000 71 71 70.4/70.9 70.4/70.9 74 75 RLA 10.3 11.7 16.7 15.3 21.2 28.8 LRA 52.0 58.0 82.0 83.0 104.0 152.9 Cooling Capacity Nominal Cooling (BTU/h) Decibels Compressor Condenser Fan Motor Horsepower (RPM) 1/6 1/6 1/6 1/6 1/6 1/6 FLA 1.1 1.1 0.9 0.9 1.2 1.0 Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Line Size (“O.D.) ¾" ¾" ⅞" ⅞" 1⅛" 1⅛" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Refrigeration System Refrigerant Line Size¹ Refrigerant Connection Size Liquid Valve Size (“O.D.) Suction Valve Size (“O.D.) Valve Connection Type Refrigerant Charge ¾" ¾" ¾" ¾" ⅞" ⅞" Sweat Sweat Sweat Sweat Sweat Sweat 97 97 107 107 132 197 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60 14.0 15.7 21.8 20.0 27.7 37.2 20 20 35 35 45 60 Electrical Data Voltage-Hz Minimum Circuit Ampacity ² Max. Overcurrent Protection ³ Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 Power Supply ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" Eqipment Weight (lbs) 181 181 184 184 219 279 Ship Weight (lbs) 198 198 202 202 241 301 ¹ Tested and rated in accordance with ARI Standard 210/240 ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL. SS-DSXC16 www.goodmanmfg.com 3 4 www.goodmanmfg.com 18.3 0.85 21 1.10 4.5 228 122 17.8 0.81 22 1.09 4.4 226 120 16.4 0.78 22 1.08 4.4 223 119 MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR 525 600 675 59 18.0 0.75 18 1.10 4.5 228 122 17.5 0.71 19 1.09 4.4 226 120 16.1 0.69 19 1.08 4.4 223 119 Airflow MBh S/T ∆T kW 675 Amps HI PR Lo PR MBh S/T ∆T kW 600 Amps HI PR Lo PR MBh S/T ∆T 525 kW Amps HI PR Lo PR 18.8 0.76 20 1.12 4.6 245 125 18.3 0.73 20 1.11 4.5 243 124 16.9 0.70 21 1.10 4.5 240 123 63 18.7 0.63 16 1.12 4.6 245 125 18.1 0.60 17 1.11 4.5 243 124 16.7 0.58 17 1.10 4.5 240 123 20.4 0.58 16 1.16 4.7 248 137 19.8 0.55 17 1.15 4.7 246 136 18.3 0.53 17 1.14 4.6 244 134 67 20.4 0.43 12 1.16 4.7 248 137 19.8 0.41 13 1.15 4.7 246 136 18.3 0.40 13 1.14 4.6 244 134 21.9 0.37 11 1.20 4.9 254 146 21.3 0.35 12 1.19 4.8 251 144 19.6 0.34 12 1.18 4.8 249 143 71 17.9 0.88 21 1.19 4.8 258 125 17.4 0.84 22 1.18 4.8 255 124 16.0 0.81 23 1.17 4.7 252 123 59 17.6 0.78 19 1.19 4.8 258 125 17.1 0.74 19 1.18 4.8 255 124 15.8 0.71 20 1.17 4.7 252 123 18.4 0.79 20 1.21 4.9 277 129 17.9 0.75 21 1.20 4.9 274 128 16.5 0.73 21 1.19 4.8 271 127 63 18.2 0.65 16 1.21 4.9 277 129 17.7 0.62 17 1.20 4.9 274 128 16.3 0.60 17 1.19 4.8 271 127 19.9 0.60 16 1.25 5.1 281 141 19.3 0.57 17 1.24 5.0 278 140 17.9 0.55 17 1.23 5.0 275 138 67 20.0 0.45 12 1.25 5.1 281 141 19.4 0.43 13 1.24 5.0 278 140 17.9 0.41 13 1.23 5.0 275 138 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 21.4 0.38 11 1.30 5.3 287 150 20.8 0.37 12 1.29 5.2 284 149 19.2 0.35 12 1.27 5.2 281 147 71 17.5 0.90 22 1.26 5.2 293 129 16.9 0.86 22 1.25 5.2 290 128 15.6 0.83 23 1.24 5.1 287 127 59 17.2 0.80 19 1.26 5.2 293 129 16.7 0.76 19 1.25 5.2 290 128 15.4 0.73 20 1.24 5.1 287 127 18.0 0.81 20 1.29 5.3 315 133 17.4 0.77 21 1.28 5.3 312 132 16.1 0.74 21 1.27 5.3 309 131 19.4 0.61 16 1.34 5.5 319 146 18.9 0.58 17 1.33 5.5 316 144 17.4 0.56 17 1.31 5.4 313 143 20.9 0.39 11 1.38 5.7 326 155 20.3 0.38 12 1.37 5.7 323 154 18.7 0.36 12 1.36 5.6 320 152 17.5 0.84 20 1.37 5.7 359 137 17.0 0.80 21 1.35 5.7 355 136 15.7 0.77 21 1.34 5.6 352 134 19.0 0.63 16 1.41 5.9 364 150 18.4 0.60 17 1.40 5.8 360 148 17.0 0.58 17 1.39 5.8 357 147 20.4 0.41 11 1.46 6.1 372 159 19.8 0.39 12 1.45 6.1 368 158 18.2 0.37 12 1.44 6.0 364 156 71 16.2 0.97 21 1.39 5.9 375 135 15.7 0.92 22 1.38 5.9 372 134 14.5 0.89 23 1.37 5.8 368 133 59 15.9 0.85 18 1.39 5.9 375 135 15.4 0.81 19 1.38 5.9 372 134 14.3 0.78 20 1.37 5.8 368 133 Shaded area reflects ACCA (TVA) conditions 17.0 0.93 22 1.33 5.6 334 133 16.5 0.89 23 1.32 5.5 330 132 15.3 0.86 23 1.31 5.5 327 130 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 17.8 19.5 16.7 17.4 19.0 0.66 0.46 0.82 0.69 0.48 16 12 19 16 12 1.29 1.34 1.33 1.37 1.41 5.3 5.5 5.6 5.7 5.9 315 319 334 359 364 133 146 133 137 150 17.3 18.9 16.3 16.8 18.5 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 1.28 1.33 1.32 1.35 1.40 5.3 5.5 5.5 5.7 5.8 312 316 330 355 360 132 144 132 136 148 15.9 17.5 15.0 15.6 17.0 0.61 0.42 0.76 0.63 0.44 17 13 20 17 13 1.27 1.31 1.31 1.34 1.39 5.3 5.4 5.5 5.6 5.8 309 313 327 352 357 131 143 130 134 147 16.7 0.87 20 1.43 6.1 404 140 16.2 0.83 20 1.41 6.0 400 138 14.9 0.80 21 1.40 6.0 396 137 63 16.5 0.71 16 1.43 6.1 404 140 16.0 0.68 17 1.41 6.0 400 138 14.8 0.65 17 1.40 6.0 396 137 18.0 0.66 16 1.48 6.3 409 153 17.5 0.63 17 1.46 6.2 405 151 16.2 0.60 17 1.45 6.2 401 150 67 18.1 0.49 12 1.48 6.3 409 153 17.5 0.47 13 1.46 6.2 405 151 16.2 0.45 13 1.45 6.2 401 150 105ºF 15.0 0.98 20 1.44 6.3 420 139 14.5 0.93 21 1.43 6.2 416 137 13.4 0.90 21 1.42 6.2 412 136 59 14.7 0.86 17 1.44 6.3 420 139 14.3 0.82 18 1.43 6.2 416 137 13.2 0.79 18 1.42 6.2 412 136 15.4 0.87 18 1.48 6.4 452 143 15.0 0.83 19 1.47 6.4 447 142 13.8 0.80 19 1.45 6.3 443 140 63 15.3 0.72 15 1.48 6.4 452 143 14.8 0.68 16 1.47 6.4 447 142 13.7 0.66 16 1.45 6.3 443 140 16.7 0.66 15 1.53 6.6 458 156 16.2 0.63 16 1.52 6.6 454 155 15.0 0.61 16 1.50 6.5 449 153 67 16.7 0.50 11 1.53 6.6 458 156 16.2 0.47 12 1.52 6.6 454 155 15.0 0.46 12 1.50 6.5 449 153 17.9 0.43 10 1.58 6.9 468 166 17.4 0.41 11 1.57 6.8 464 165 16.1 0.39 11 1.56 6.8 459 163 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 19.3 0.42 11 1.53 6.5 418 162 18.8 0.40 12 1.51 6.4 414 161 17.3 0.39 12 1.50 6.4 410 159 71 - 115ºF Product Specifications Expanded Cooling Data — DSXC160241**/ CA*F3636C6C*+TXV/ MBVC1200** Low Stage SS-DSXC16 SS-DSXC16 www.goodmanmfg.com 19.0 0.98 25 1.10 4.5 228 122 18.4 0.93 26 1.09 4.4 226 120 17.0 0.90 26.8 1.08 4.4 223 119 MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR 525 600 675 59 18.6 0.93 24 1.10 4.5 228 122 18.1 0.89 25 1.09 4.4 226 120 16.7 0.86 25 1.08 4.4 223 119 Airflow MBh S/T ∆T kW 675 Amps HI PR Lo PR MBh S/T ∆T kW 600 Amps HI PR Lo PR MBh S/T ∆T 525 kW Amps HI PR Lo PR 19.3 0.94 25 1.12 4.6 245 125 18.8 0.90 26 1.11 4.5 243 124 17.3 0.87 26 1.10 4.5 240 123 63 19.0 0.88 23 1.12 4.6 245 125 18.5 0.84 24 1.11 4.5 243 124 17.1 0.81 24 1.10 4.5 240 123 20.2 0.85 23 1.16 4.7 248 137 19.6 0.81 24 1.15 4.7 246 136 18.1 0.78 25 1.14 4.6 244 134 67 20.3 0.71 20 1.16 4.7 248 137 19.7 0.68 21 1.15 4.7 246 136 18.2 0.66 21 1.14 4.6 244 134 21.6 0.69 20 1.20 4.9 254 146 21.0 0.66 21 1.19 4.8 251 144 19.3 0.64 22 1.18 4.8 249 143 71 21.7 0.53 16 1.20 4.9 254 146 21.1 0.51 16 1.19 4.8 251 144 19.5 0.49 17 1.18 4.8 249 143 18.5 1.00 25 1.19 4.8 258 125 18.0 0.97 27 1.18 4.8 255 124 16.6 0.93 27 1.17 4.7 252 123 59 18.2 0.97 24 1.19 4.8 258 125 17.7 0.92 25 1.18 4.8 255 124 16.3 0.89 25 1.17 4.7 252 123 18.9 0.98 25 1.21 4.9 277 129 18.3 0.93 26 1.20 4.9 274 128 16.9 0.90 27 1.19 4.8 271 127 63 18.6 0.91 23 1.21 4.9 277 129 18.1 0.87 24 1.20 4.9 274 128 16.7 0.83 24 1.19 4.8 271 127 19.8 0.88 24 1.25 5.1 281 141 19.2 0.84 25 1.24 5.0 278 140 17.7 0.81 25 1.23 5.0 275 138 67 19.9 0.74 20 1.25 5.1 281 141 19.3 0.70 21 1.24 5.0 278 140 17.8 0.68 21 1.23 5.0 275 138 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 21.1 0.72 21 1.30 5.3 287 150 20.5 0.68 21 1.29 5.2 284 149 18.9 0.66 22 1.27 5.2 281 147 71 21.2 0.55 16 1.30 5.3 287 150 20.6 0.53 17 1.29 5.2 284 149 19.0 0.51 17 1.27 5.2 281 147 18.1 1.00 25 1.26 5.2 293 129 17.5 0.99 27 1.25 5.2 290 128 16.2 0.96 27 1.24 5.1 287 127 59 17.8 1.00 24 1.26 5.2 293 129 17.2 0.95 25 1.25 5.2 290 128 15.9 0.91 25 1.24 5.1 287 127 18.4 1.00 25 1.29 5.3 315 133 17.9 0.96 26 1.28 5.3 312 132 16.5 0.92 27 1.27 5.3 309 131 19.3 0.91 24 1.34 5.5 319 146 18.7 0.86 25 1.33 5.5 316 144 17.3 0.83 25 1.31 5.4 313 143 20.6 0.73 21 1.38 5.7 326 155 20.0 0.70 21 1.37 5.7 323 154 18.4 0.68 22 1.36 5.6 320 152 18.0 1.00 24 1.37 5.7 359 137 17.4 0.99 26 1.35 5.7 355 136 16.1 0.95 27 1.34 5.6 352 134 18.8 0.93 24 1.41 5.9 364 150 18.3 0.89 25 1.40 5.8 360 148 16.9 0.86 25 1.39 5.8 357 147 20.1 0.76 21 1.46 6.1 372 159 19.5 0.72 22 1.45 6.1 368 158 18.0 0.70 22 1.44 6.0 364 156 71 20.2 0.58 16 1.46 6.1 372 159 19.6 0.56 17 1.45 6.1 368 158 18.1 0.54 17 1.44 6.0 364 156 16.8 1.00 23 1.39 5.9 375 135 16.3 1.00 25 1.38 5.9 372 134 15.0 1.00 26 1.37 5.8 368 133 59 16.5 1.00 22 1.39 5.9 375 135 16.0 1.00 24 1.38 5.9 372 134 14.8 0.98 25 1.37 5.8 368 133 Shaded area reflects AHRI (TVA) conditions 17.6 1.00 24 1.33 5.6 334 133 17.1 1.00 26 1.32 5.5 330 132 15.8 0.99 27 1.31 5.5 327 130 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 18.1 19.4 20.7 17.3 17.7 18.9 0.93 0.76 0.57 1.00 0.96 0.78 23 20 16 24 23 20 1.29 1.34 1.38 1.33 1.37 1.41 5.3 5.5 5.7 5.6 5.7 5.9 315 319 326 334 359 364 133 146 155 133 137 150 17.6 18.8 20.1 16.8 17.2 18.4 0.89 0.72 0.54 0.98 0.92 0.75 24 21 17 25 24 21 1.28 1.33 1.37 1.32 1.35 1.40 5.3 5.5 5.7 5.5 5.7 5.8 312 316 323 330 355 360 132 144 154 132 136 148 16.3 17.4 18.6 15.5 15.9 17.0 0.86 0.70 0.52 0.94 0.88 0.72 24 21 17 26 25 21 1.27 1.31 1.36 1.31 1.34 1.39 5.3 5.4 5.6 5.5 5.6 5.8 309 313 320 327 352 357 131 143 152 130 134 147 17.1 1.00 23 1.43 6.1 404 140 16.6 1.00 25 1.41 6.0 400 138 15.3 0.99 26 1.40 6.0 396 137 63 16.8 1.00 23 1.43 6.1 404 140 16.3 0.95 24 1.41 6.0 400 138 15.1 0.92 24 1.40 6.0 396 137 17.9 0.97 24 1.48 6.3 409 153 17.4 0.93 25 1.46 6.2 405 151 16.0 0.89 25 1.45 6.2 401 150 67 18.0 0.81 20 1.48 6.3 409 153 17.4 0.77 21 1.46 6.2 405 151 16.1 0.75 21 1.45 6.2 401 150 105ºF 15.5 1.00 21 1.44 6.3 420 139 15.1 1.00 23 1.43 6.2 416 137 13.9 1.00 24 1.42 6.2 412 136 59 15.2 1.00 21 1.44 6.3 420 139 14.8 1.00 23 1.43 6.2 416 137 13.7 0.99 24 1.42 6.2 412 136 15.8 1.00 22 1.48 6.4 452 143 15.4 1.00 24 1.47 6.4 447 142 14.2 1.00 25 1.45 6.3 443 140 63 15.6 1.00 21 1.48 6.4 452 143 15.1 0.96 22 1.47 6.4 447 142 14.0 0.92 23 1.45 6.3 443 140 16.6 0.98 22 1.53 6.6 458 156 16.1 0.93 23 1.52 6.6 454 155 14.8 0.90 23 1.50 6.5 449 153 67 16.6 0.82 19 1.53 6.6 458 156 16.2 0.78 19 1.52 6.6 454 155 14.9 0.75 20 1.50 6.5 449 153 17.7 0.79 19 1.58 6.9 468 166 17.2 0.76 20 1.57 6.8 464 165 15.8 0.73 20 1.56 6.8 459 163 71 17.8 0.61 15 1.58 6.9 468 166 17.3 0.58 15 1.57 6.8 464 165 15.9 0.56 16 1.56 6.8 459 163 kW = Total system power Amps = outdoor unit amps (comp.+fan) 19.1 0.79 20 1.53 6.5 418 162 18.5 0.75 21 1.51 6.4 414 161 17.1 0.72 22 1.50 6.4 410 159 71 19.2 0.61 16 1.53 6.5 418 162 18.7 0.58 17 1.51 6.4 414 161 17.2 0.56 17 1.50 6.4 410 159 115ºF Product Specifications Expanded Cooling Data — DSXC160241**/ CA*F3636C6C*+TXV/ MBVC1200** Low Stage (cont.) 5 6 www.goodmanmfg.com 23.9 0.86 21 1.50 5.9 237 122 23.2 0.82 22 1.49 5.9 234 120 21.4 0.79 22 1.48 5.8 232 119 MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR 700 800 900 59 23.5 0.76 18 1.50 5.9 237 122 22.8 0.72 19 1.49 5.9 234 120 21.1 0.70 19 1.48 5.8 232 119 Airflow MBh S/T ∆T kW 900 Amps HI PR Lo PR MBh S/T ∆T kW 800 Amps HI PR Lo PR MBh S/T ∆T 700 kW Amps HI PR Lo PR 24.6 0.77 19 1.53 6.0 255 125 23.9 0.73 20 1.52 6.0 252 124 22.1 0.71 21 1.51 5.9 249 123 63 24.4 0.63 16 1.53 6.0 255 125 23.7 0.60 16 1.52 6.0 252 124 21.8 0.58 17 1.51 5.9 249 123 26.7 0.58 16 1.58 6.2 258 137 25.9 0.56 17 1.57 6.2 256 136 23.9 0.54 17 1.56 6.1 253 134 67 26.7 0.44 12 1.58 6.2 258 137 25.9 0.42 12 1.57 6.2 256 136 23.9 0.40 13 1.56 6.1 253 134 28.6 0.37 11 1.63 6.5 264 146 27.8 0.36 11 1.62 6.4 261 144 25.6 0.34 12 1.61 6.3 259 143 71 23.4 0.89 21 1.62 6.4 268 125 22.7 0.85 22 1.61 6.3 265 124 20.9 0.82 23 1.59 6.3 262 123 59 23.0 0.78 18 1.62 6.4 268 125 22.3 0.75 19 1.61 6.3 265 124 20.6 0.72 20 1.59 6.3 262 123 24.1 0.80 20 1.65 6.5 288 129 23.4 0.76 20 1.64 6.5 285 128 21.6 0.73 21 1.63 6.4 282 127 63 23.8 0.66 16 1.65 6.5 288 129 23.1 0.63 17 1.64 6.5 285 128 21.3 0.60 17 1.63 6.4 282 127 26.0 0.60 16 1.71 6.7 292 141 25.3 0.58 17 1.69 6.7 289 140 23.3 0.56 17 1.68 6.6 286 138 67 26.1 0.45 12 1.71 6.7 292 141 25.3 0.43 13 1.69 6.7 289 140 23.4 0.42 13 1.68 6.6 286 138 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 27.9 0.39 11 1.77 7.0 298 150 27.1 0.37 12 1.75 6.9 295 149 25.0 0.36 12 1.74 6.8 292 147 71 22.8 0.91 21 1.72 6.9 304 129 22.1 0.87 22 1.71 6.8 301 128 20.4 0.84 23 1.69 6.8 298 127 59 22.4 0.80 18 1.72 6.9 304 129 21.8 0.77 19 1.71 6.8 301 128 20.1 0.74 20 1.69 6.8 298 127 23.5 0.82 20 1.76 7.1 327 134 22.8 0.78 20 1.75 7.0 324 132 21.0 0.75 21 1.73 6.9 321 131 25.4 0.62 16 1.82 7.3 332 146 24.7 0.59 17 1.80 7.2 329 144 22.8 0.57 17 1.79 7.2 325 143 27.3 0.40 11 1.88 7.6 339 155 26.5 0.38 12 1.87 7.5 336 154 24.4 0.37 12 1.85 7.4 332 152 22.9 0.84 20 1.86 7.5 373 137 22.2 0.81 21 1.84 7.5 369 136 20.5 0.78 21 1.82 7.4 365 134 24.8 0.64 16 1.92 7.8 378 150 24.1 0.61 17 1.90 7.7 374 148 22.2 0.59 17 1.89 7.6 370 147 26.6 0.41 11 1.98 8.1 386 159 25.8 0.39 12 1.97 8.0 382 158 23.8 0.38 12 1.95 7.9 379 156 71 21.1 0.98 21 1.89 7.8 390 136 20.5 0.93 22 1.88 7.8 386 134 18.9 0.90 22 1.86 7.7 382 133 59 20.8 0.86 18 1.89 7.8 390 136 20.2 0.82 19 1.88 7.8 386 134 18.6 0.79 19 1.86 7.7 382 133 Shaded area reflects ACCA (TVA) conditions 22.2 0.94 21 1.81 7.4 347 133 21.6 0.90 22 1.80 7.3 343 132 19.9 0.87 23 1.78 7.2 340 130 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 23.2 25.5 21.9 22.7 24.8 0.67 0.47 0.83 0.69 0.48 16 12 19 16 12 1.76 1.82 1.81 1.86 1.92 7.1 7.3 7.4 7.5 7.8 327 332 347 373 378 134 146 133 137 150 22.6 24.7 21.2 22.0 24.1 0.64 0.44 0.79 0.66 0.46 17 13 19 17 13 1.75 1.80 1.80 1.84 1.90 7.0 7.2 7.3 7.5 7.7 324 329 343 369 374 132 144 132 136 148 20.8 22.8 19.6 20.3 22.3 0.62 0.43 0.76 0.64 0.44 17 13 20 17 13 1.73 1.79 1.78 1.82 1.89 6.9 7.2 7.2 7.4 7.6 321 325 340 365 370 131 143 130 134 147 21.8 0.88 19 1.94 8.0 419 140 21.1 0.84 20 1.92 7.9 415 138 19.5 0.81 21 1.90 7.9 411 137 63 21.5 0.72 16 1.94 8.0 419 140 20.9 0.69 17 1.92 7.9 415 138 19.3 0.66 17 1.90 7.9 411 137 23.6 0.66 16 2.00 8.3 425 153 22.9 0.63 17 1.98 8.2 421 151 21.1 0.61 17 1.97 8.1 417 150 67 23.6 0.50 12 2.00 8.3 425 153 22.9 0.48 13 1.98 8.2 421 151 21.1 0.46 13 1.97 8.1 417 150 105ºF 19.6 0.99 20 1.96 8.3 437 139 19.0 0.94 21 1.94 8.2 432 138 17.5 0.91 21 1.93 8.1 428 136 59 19.3 0.87 17 1.96 8.3 437 139 18.7 0.83 18 1.94 8.2 432 138 17.3 0.80 18 1.93 8.1 428 136 20.2 0.88 18 2.01 8.5 470 143 19.6 0.84 19 1.99 8.4 465 142 18.1 0.81 19 1.97 8.3 460 140 63 20.0 0.73 15 2.01 8.5 470 143 19.4 0.69 15 1.99 8.4 465 142 17.9 0.67 16 1.97 8.3 460 140 21.8 0.67 15 2.07 8.7 476 156 21.2 0.64 16 2.06 8.7 471 155 19.6 0.62 16 2.04 8.6 467 153 67 21.9 0.50 11 2.07 8.7 476 156 21.2 0.48 12 2.06 8.7 471 155 19.6 0.46 12 2.04 8.6 467 153 23.4 0.43 10 2.15 9.1 487 167 22.7 0.41 11 2.13 9.0 482 165 21.0 0.40 11 2.11 8.9 477 163 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 25.3 0.43 11 2.07 8.6 435 163 24.5 0.41 11 2.05 8.5 430 161 22.7 0.39 12 2.04 8.4 426 159 71 - 115ºF Product Specifications Expanded Cooling Data — DSXC160241**/ CA*F3636C6C*+TXV/ MBVC1200** High Stage SS-DSXC16 SS-DSXC16 www.goodmanmfg.com 24.8 0.99 25 1.50 5.9 237 122 24.0 0.94 26 1.49 5.9 234 120 22.2 0.91 26.5 1.48 5.8 232 119 MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR 700 800 900 59 24.3 0.94 23 1.50 5.9 237 122 23.6 0.90 24 1.49 5.9 234 120 21.8 0.87 25 1.48 5.8 232 119 Airflow MBh S/T ∆T kW 900 Amps HI PR Lo PR MBh S/T ∆T kW 800 Amps HI PR Lo PR MBh S/T ∆T 700 kW Amps HI PR Lo PR 25.2 0.96 25 1.53 6.0 255 125 24.5 0.91 26 1.52 6.0 252 124 22.6 0.88 26 1.51 5.9 249 123 63 24.9 0.89 22 1.53 6.0 255 125 24.1 0.84 23 1.52 6.0 252 124 22.3 0.81 24 1.51 5.9 249 123 26.4 0.86 23 1.58 6.2 258 137 25.7 0.82 24 1.57 6.2 256 136 23.7 0.79 25 1.56 6.1 253 134 67 26.6 0.72 20 1.58 6.2 258 137 25.8 0.69 20 1.57 6.2 256 136 23.8 0.66 21 1.56 6.1 253 134 28.2 0.70 20 1.63 6.5 264 146 27.4 0.67 21 1.62 6.4 261 144 25.3 0.64 21 1.61 6.3 259 143 71 28.4 0.54 16 1.63 6.5 264 146 27.6 0.51 16 1.62 6.4 261 144 25.5 0.50 17 1.61 6.3 259 143 24.2 1.00 25 1.62 6.4 268 125 23.5 0.98 26 1.61 6.3 265 124 21.7 0.94 27 1.59 6.3 262 123 59 23.8 1.00 24 1.62 6.4 268 125 23.1 0.93 25 1.61 6.3 265 124 21.3 0.90 25 1.59 6.3 262 123 24.7 0.99 25 1.65 6.5 288 129 23.9 0.94 26 1.64 6.5 285 128 22.1 0.91 26 1.63 6.4 282 127 63 24.3 0.92 23 1.65 6.5 288 129 23.6 0.88 24 1.64 6.5 285 128 21.8 0.84 24 1.63 6.4 282 127 25.8 0.89 24 1.71 6.7 292 141 25.1 0.85 25 1.69 6.7 289 140 23.1 0.82 25 1.68 6.6 286 138 67 26.0 0.75 20 1.71 6.7 292 141 25.2 0.71 21 1.69 6.7 289 140 23.3 0.69 21 1.68 6.6 286 138 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 27.6 0.72 20 1.77 7.0 298 150 26.8 0.69 21 1.75 6.9 295 149 24.7 0.67 22 1.74 6.8 292 147 71 27.7 0.56 16 1.77 7.0 298 150 26.9 0.53 16 1.75 6.9 295 149 24.9 0.51 17 1.74 6.8 292 147 23.6 1.00 24 1.72 6.9 304 129 22.9 1.00 26 1.71 6.8 301 128 21.2 0.97 27 1.69 6.8 298 127 59 23.2 1.00 24 1.72 6.9 304 129 22.5 0.96 25 1.71 6.8 301 128 20.8 0.92 25 1.69 6.8 298 127 24.1 1.00 25 1.76 7.1 327 134 23.4 0.97 26 1.75 7.0 324 132 21.6 0.93 26 1.73 6.9 321 131 25.2 0.92 24 1.82 7.3 332 146 24.5 0.87 25 1.80 7.2 329 144 22.6 0.84 25 1.79 7.2 325 143 26.9 0.74 20 1.88 7.6 339 155 26.1 0.71 21 1.87 7.5 336 154 24.1 0.68 22 1.85 7.4 332 152 23.5 1.00 24 1.86 7.5 373 137 22.8 1.00 26 1.84 7.5 369 136 21.0 0.96 27 1.82 7.4 365 134 24.6 0.95 24 1.92 7.8 378 150 23.9 0.90 25 1.90 7.7 374 148 22.0 0.87 25 1.89 7.6 370 147 26.2 0.77 21 1.98 8.1 386 159 25.5 0.73 21 1.97 8.0 382 158 23.5 0.71 22 1.95 7.9 379 156 71 26.4 0.59 16 1.98 8.1 386 159 25.7 0.56 17 1.97 8.0 382 158 23.7 0.54 17 1.95 7.9 379 156 21.9 1.00 22 1.89 7.8 390 136 21.2 1.00 24 1.88 7.8 386 134 19.6 1.00 26 1.86 7.7 382 133 59 21.5 1.00 22 1.89 7.8 390 136 20.9 1.00 24 1.88 7.8 386 134 19.3 0.99 25 1.86 7.7 382 133 Shaded area reflects AHRI (TVA) conditions 23.0 1.00 24 1.81 7.4 347 133 22.4 1.00 26 1.80 7.3 343 132 20.6 1.00 27 1.78 7.2 340 130 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 23.7 25.3 27.1 22.6 23.1 24.7 0.94 0.77 0.57 1.00 1.00 0.79 23 20 16 23 24 20 1.76 1.82 1.88 1.81 1.86 1.92 7.1 7.3 7.6 7.4 7.5 7.8 327 332 339 347 373 378 134 146 155 133 137 150 23.0 24.6 26.3 22.0 22.5 24.0 0.90 0.73 0.55 0.99 0.93 0.75 24 21 16 25 24 21 1.75 1.80 1.87 1.80 1.84 1.90 7.0 7.2 7.5 7.3 7.5 7.7 324 329 336 343 369 374 132 144 154 132 136 148 21.3 22.7 24.3 20.3 20.7 22.2 0.87 0.70 0.53 0.95 0.89 0.73 24 21 17 25 24 21 1.73 1.79 1.85 1.78 1.82 1.89 6.9 7.2 7.4 7.2 7.4 7.6 321 325 332 340 365 370 131 143 152 130 134 147 22.3 1.00 23 1.94 8.0 419 140 21.7 1.00 25 1.92 7.9 415 138 20.0 1.00 26 1.90 7.9 411 137 63 22.0 1.00 22 1.94 8.0 419 140 21.3 0.96 24 1.92 7.9 415 138 19.7 0.93 24 1.90 7.9 411 137 23.4 0.98 23 2.00 8.3 425 153 22.7 0.94 24 1.98 8.2 421 151 20.9 0.90 25 1.97 8.1 417 150 67 23.5 0.82 20 2.00 8.3 425 153 22.8 0.78 21 1.98 8.2 421 151 21.0 0.75 21 1.97 8.1 417 150 105ºF 20.3 1.00 21 1.96 8.3 437 139 19.7 1.00 23 1.94 8.2 432 138 18.2 1.00 24 1.93 8.1 428 136 59 19.9 1.00 20 1.96 8.3 437 139 19.3 1.00 22 1.94 8.2 432 138 17.9 1.00 23 1.93 8.1 428 136 20.7 1.00 21 2.01 8.5 470 143 20.1 1.00 23 1.99 8.4 465 142 18.5 1.00 24 1.97 8.3 460 140 63 20.4 1.00 21 2.01 8.5 470 143 19.8 0.97 22 1.99 8.4 465 142 18.2 0.93 22 1.97 8.3 460 140 21.6 0.99 22 2.07 8.7 476 156 21.0 0.94 23 2.06 8.7 471 155 19.4 0.91 23 2.04 8.6 467 153 67 21.8 0.83 18 2.07 8.7 476 156 21.1 0.79 19 2.06 8.7 471 155 19.5 0.76 19 2.04 8.6 467 153 23.1 0.80 19 2.15 9.1 487 167 22.4 0.77 20 2.13 9.0 482 165 20.7 0.74 20 2.11 8.9 477 163 71 23.3 0.62 15 2.15 9.1 487 167 22.6 0.59 15 2.13 9.0 482 165 20.8 0.57 16 2.11 8.9 477 163 kW = Total system power Amps = outdoor unit amps (comp.+fan) 24.9 0.80 20 2.07 8.6 435 163 24.2 0.76 21 2.05 8.5 430 161 22.3 0.73 21 2.04 8.4 426 159 71 25.1 0.61 16 2.07 8.6 435 163 24.4 0.58 16 2.05 8.5 430 161 22.5 0.56 17 2.04 8.4 426 159 115ºF Product Specifications Expanded Cooling Data — DSXC160241**/ CA*F3636C6C*+TXV/ MBVC1200** High Stage (cont.) 7 8 www.goodmanmfg.com 25.3 0.81 21 1.50 5.8 220 119 24.6 0.78 22 1.49 5.8 218 118 22.7 0.75 22 1.47 5.7 216 117 MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR 696 800 904 59 24.9 0.72 18 1.50 5.8 220 119 24.2 0.68 19 1.49 5.8 218 118 22.3 0.66 19 1.47 5.7 216 117 Airflow MBh S/T ∆T kW 904 Amps HI PR Lo PR MBh S/T ∆T kW 800 Amps HI PR Lo PR MBh S/T ∆T 696 kW Amps HI PR Lo PR 26.1 0.73 19 1.53 6.0 237 123 25.3 0.69 20 1.52 5.9 234 122 23.4 0.67 21 1.51 5.9 232 121 63 25.8 0.60 16 1.53 6.0 237 123 25.1 0.57 16 1.52 5.9 234 122 23.1 0.55 17 1.51 5.9 232 121 28.2 0.55 16 1.58 6.2 240 134 27.4 0.53 17 1.57 6.1 238 133 25.3 0.51 17 1.55 6.0 235 132 67 28.3 0.41 12 1.58 6.2 240 134 27.5 0.40 12 1.57 6.1 238 133 25.3 0.38 13 1.55 6.0 235 132 30.3 0.35 11 1.63 6.4 245 143 29.4 0.34 11 1.62 6.3 243 142 27.2 0.33 12 1.60 6.3 241 140 71 24.7 0.84 21 1.61 6.3 249 123 24.0 0.80 22 1.60 6.2 246 122 22.2 0.78 23 1.59 6.2 244 120 59 24.3 0.74 18 1.61 6.3 249 123 23.6 0.71 19 1.60 6.2 246 122 21.8 0.68 20 1.59 6.2 244 120 25.5 0.75 20 1.65 6.4 268 127 24.7 0.72 20 1.64 6.4 265 125 22.8 0.69 21 1.62 6.3 262 124 63 25.2 0.62 16 1.65 6.4 268 127 24.5 0.59 17 1.64 6.4 265 125 22.6 0.57 17 1.62 6.3 262 124 27.6 0.57 16 1.70 6.6 271 138 26.8 0.54 17 1.69 6.6 269 137 24.7 0.53 17 1.67 6.5 266 136 67 27.6 0.43 12 1.70 6.6 271 138 26.8 0.41 13 1.69 6.6 269 137 24.8 0.39 13 1.67 6.5 266 136 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 29.6 0.37 11 1.76 6.9 277 147 28.7 0.35 12 1.74 6.8 275 146 26.5 0.34 12 1.73 6.8 272 144 71 24.2 0.87 21 1.72 6.8 283 127 23.5 0.83 22 1.70 6.7 280 126 21.6 0.80 23 1.69 6.7 277 125 59 23.8 0.76 18 1.72 6.8 283 127 23.1 0.73 19 1.70 6.7 280 126 21.3 0.70 20 1.69 6.7 277 125 24.9 0.77 20 1.75 7.0 304 131 24.1 0.74 20 1.74 6.9 301 130 22.3 0.71 21 1.73 6.8 298 128 26.9 0.59 16 1.81 7.2 309 143 26.1 0.56 17 1.80 7.1 306 142 24.1 0.54 17 1.78 7.1 303 140 28.9 0.38 11 1.87 7.4 315 152 28.0 0.36 12 1.86 7.4 312 151 25.9 0.35 12 1.84 7.3 309 149 24.3 0.80 20 1.85 7.4 347 135 23.6 0.76 21 1.83 7.4 343 133 21.7 0.73 21 1.82 7.3 340 132 26.3 0.60 16 1.91 7.7 352 147 25.5 0.58 17 1.89 7.6 348 145 23.5 0.56 17 1.88 7.5 345 144 28.2 0.39 11 1.97 7.9 359 156 27.4 0.37 12 1.96 7.9 356 155 25.3 0.36 12 1.94 7.8 352 153 71 22.4 0.93 21 1.88 7.7 348 133 21.7 0.88 22 1.87 7.6 345 132 20.1 0.85 23 1.85 7.6 341 130 59 22.0 0.82 18 1.88 7.7 348 133 21.4 0.78 19 1.87 7.6 345 132 19.7 0.75 20 1.85 7.6 341 130 Shaded area reflects ACCA (TVA) conditions 23.6 0.89 21 1.81 7.3 322 130 22.9 0.85 22 1.79 7.2 319 129 21.1 0.82 23 1.78 7.1 316 128 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 24.6 27.0 23.2 24.0 26.3 0.64 0.44 0.79 0.66 0.45 16 12 19 16 12 1.75 1.81 1.81 1.85 1.91 7.0 7.2 7.3 7.4 7.7 304 309 322 347 352 131 143 130 135 147 23.9 26.2 22.5 23.3 25.5 0.61 0.42 0.75 0.63 0.43 17 13 19 17 13 1.74 1.80 1.79 1.83 1.89 6.9 7.1 7.2 7.4 7.6 301 306 319 343 348 130 142 129 133 145 22.1 24.2 20.8 21.5 23.6 0.58 0.40 0.72 0.60 0.42 17 13 20 17 13 1.73 1.78 1.78 1.82 1.88 6.8 7.1 7.1 7.3 7.5 298 303 316 340 345 128 140 128 132 144 23.0 0.83 19 1.93 7.9 374 137 22.4 0.79 20 1.91 7.8 371 136 20.7 0.76 21 1.89 7.8 367 134 63 22.8 0.68 16 1.93 7.9 374 137 22.2 0.65 17 1.91 7.8 371 136 20.4 0.63 17 1.89 7.8 367 134 24.9 0.63 16 1.99 8.1 380 150 24.2 0.60 17 1.97 8.1 376 148 22.4 0.58 17 1.96 8.0 372 147 67 25.0 0.47 12 1.99 8.1 380 150 24.3 0.45 13 1.97 8.1 376 148 22.4 0.43 13 1.96 8.0 372 147 105ºF 20.7 0.93 20 1.95 8.2 413 136 20.1 0.89 21 1.93 8.1 409 135 18.6 0.86 21 1.92 8.0 404 134 59 20.4 0.82 17 1.95 8.2 413 136 19.8 0.78 18 1.93 8.1 409 135 18.3 0.76 18 1.92 8.0 404 134 21.4 0.84 18 2.00 8.3 444 141 20.7 0.80 19 1.98 8.3 439 139 19.1 0.77 19 1.96 8.2 435 138 63 21.1 0.69 15 2.00 8.3 444 141 20.5 0.65 15 1.98 8.3 439 139 18.9 0.63 16 1.96 8.2 435 138 23.1 0.63 15 2.06 8.6 450 153 22.4 0.60 16 2.04 8.5 446 152 20.7 0.58 16 2.03 8.5 441 150 67 23.2 0.48 11 2.06 8.6 450 153 22.5 0.45 12 2.04 8.5 446 152 20.8 0.44 12 2.03 8.5 441 150 24.8 0.41 10 2.13 8.9 460 163 24.1 0.39 11 2.11 8.9 455 162 22.2 0.37 11 2.10 8.8 451 160 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 26.8 0.40 11 2.06 8.4 388 160 26.0 0.38 12 2.04 8.4 384 158 24.0 0.37 12 2.02 8.3 380 156 71 - 115ºF Product Specifications Expanded Cooling Data — DSXC160361** / CA*F3743*6A* +TXV / MBVC1600** Low Stage SS-DSXC16 SS-DSXC16 www.goodmanmfg.com 26.2 0.94 25 1.50 5.8 220 119 25.5 0.89 26 1.49 5.8 218 118 23.5 0.86 26.7 1.47 5.7 216 117 MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR 696 800 904 59 25.8 0.89 23 1.50 5.8 220 119 25.0 0.85 24 1.49 5.8 218 118 23.1 0.82 25 1.47 5.7 216 117 Airflow MBh S/T ∆T kW 904 Amps HI PR Lo PR MBh S/T ∆T kW 800 Amps HI PR Lo PR MBh S/T ∆T 696 kW Amps HI PR Lo PR 26.7 0.90 25 1.53 6.0 237 123 26.0 0.86 26 1.52 5.9 234 122 24.0 0.83 26 1.51 5.9 232 121 63 26.3 0.84 22 1.53 6.0 237 123 25.6 0.80 23 1.52 5.9 234 122 23.6 0.77 24 1.51 5.9 232 121 28.0 0.82 23 1.58 6.2 240 134 27.2 0.78 24 1.57 6.1 238 133 25.1 0.75 25 1.55 6.0 235 132 67 28.1 0.68 20 1.58 6.2 240 134 27.3 0.65 20 1.57 6.1 238 133 25.2 0.63 21 1.55 6.0 235 132 29.9 0.66 20 1.63 6.4 245 143 29.0 0.63 21 1.62 6.3 243 142 26.8 0.61 22 1.60 6.3 241 140 71 30.1 0.51 16 1.63 6.4 245 143 29.2 0.49 16 1.62 6.3 243 142 27.0 0.47 17 1.60 6.3 241 140 25.6 0.97 25 1.61 6.3 249 123 24.9 0.93 26 1.60 6.2 246 122 23.0 0.89 27 1.59 6.2 244 120 59 25.2 0.93 24 1.61 6.3 249 123 24.4 0.88 25 1.60 6.2 246 122 22.6 0.85 25 1.59 6.2 244 120 26.1 0.94 25 1.65 6.4 268 127 25.4 0.89 26 1.64 6.4 265 125 23.4 0.86 27 1.62 6.3 262 124 63 25.7 0.87 23 1.65 6.4 268 127 25.0 0.83 24 1.64 6.4 265 125 23.1 0.80 24 1.62 6.3 262 124 27.4 0.84 24 1.70 6.6 271 138 26.6 0.81 25 1.69 6.6 269 137 24.5 0.78 25 1.67 6.5 266 136 67 27.5 0.71 20 1.70 6.6 271 138 26.7 0.67 21 1.69 6.6 269 137 24.6 0.65 21 1.67 6.5 266 136 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 29.2 0.69 20 1.76 6.9 277 147 28.3 0.65 21 1.74 6.8 275 146 26.2 0.63 22 1.73 6.8 272 144 71 29.4 0.53 16 1.76 6.9 277 147 28.5 0.50 17 1.74 6.8 275 146 26.3 0.49 17 1.73 6.8 272 144 25.0 0.99 25 1.72 6.8 283 127 24.3 0.95 26 1.70 6.7 280 126 22.4 0.91 27 1.69 6.7 277 125 59 24.6 0.95 24 1.72 6.8 283 127 23.9 0.90 25 1.70 6.7 280 126 22.0 0.87 25 1.69 6.7 277 125 25.5 0.96 25 1.75 7.0 304 131 24.8 0.92 26 1.74 6.9 301 130 22.8 0.88 27 1.73 6.8 298 128 26.7 0.87 24 1.81 7.2 309 143 25.9 0.83 25 1.80 7.1 306 142 23.9 0.80 25 1.78 7.1 303 140 28.5 0.70 20 1.87 7.4 315 152 27.7 0.67 21 1.86 7.4 312 151 25.5 0.65 22 1.84 7.3 309 149 24.9 0.99 25 1.85 7.4 347 135 24.2 0.94 26 1.83 7.4 343 133 22.3 0.91 27 1.82 7.3 340 132 26.1 0.89 24 1.91 7.7 352 147 25.3 0.85 25 1.89 7.6 348 145 23.3 0.82 25 1.88 7.5 345 144 27.8 0.73 21 1.97 7.9 359 156 27.0 0.69 21 1.96 7.9 356 155 24.9 0.67 22 1.94 7.8 352 153 71 28.0 0.56 16 1.97 7.9 359 156 27.2 0.53 17 1.96 7.9 356 155 25.1 0.51 17 1.94 7.8 352 153 23.2 1.00 24 1.88 7.7 348 133 22.5 1.00 26 1.87 7.6 345 132 20.8 0.98 27 1.85 7.6 341 130 59 22.8 1.00 23 1.88 7.7 348 133 22.1 0.97 25 1.87 7.6 345 132 20.4 0.93 25 1.85 7.6 341 130 Shaded area reflects AHRI (TVA) conditions 24.4 1.00 25 1.81 7.3 322 130 23.7 0.98 27 1.79 7.2 319 129 21.9 0.94 27 1.78 7.1 316 128 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 25.1 26.8 28.7 24.0 24.5 26.2 0.89 0.72 0.54 1.00 0.92 0.75 23 20 16 24 23 20 1.75 1.81 1.87 1.81 1.85 1.91 7.0 7.2 7.4 7.3 7.4 7.7 304 309 315 322 347 352 131 143 152 130 135 147 24.4 26.1 27.9 23.3 23.8 25.4 0.85 0.69 0.52 0.93 0.88 0.71 24 21 17 25 24 21 1.74 1.80 1.86 1.79 1.83 1.89 6.9 7.1 7.4 7.2 7.4 7.6 301 306 312 319 343 348 130 142 151 129 133 145 22.5 24.1 25.7 21.5 22.0 23.5 0.82 0.67 0.50 0.90 0.84 0.69 24 21 17 26 25 21 1.73 1.78 1.84 1.78 1.82 1.88 6.8 7.1 7.3 7.1 7.3 7.5 298 303 309 316 340 345 128 140 149 128 132 144 23.6 1.00 24 1.93 7.9 374 137 22.9 0.98 26 1.91 7.8 371 136 21.2 0.95 26 1.89 7.8 367 134 63 23.3 0.95 23 1.93 7.9 374 137 22.6 0.91 24 1.91 7.8 371 136 20.9 0.88 24 1.89 7.8 367 134 24.8 0.93 23 1.99 8.1 380 150 24.0 0.89 24 1.97 8.1 376 148 22.2 0.85 25 1.96 8.0 372 147 67 24.9 0.78 20 1.99 8.1 380 150 24.1 0.74 21 1.97 8.1 376 148 22.3 0.71 21 1.96 8.0 372 147 105ºF 21.5 1.00 22 1.95 8.2 413 136 20.8 1.00 24 1.93 8.1 409 135 19.2 0.99 25 1.92 8.0 404 134 59 21.1 1.00 21 1.95 8.2 413 136 20.5 0.98 23 1.93 8.1 409 135 18.9 0.94 24 1.92 8.0 404 134 21.9 1.00 22 2.00 8.3 444 141 21.3 0.99 24 1.98 8.3 439 139 19.6 0.95 25 1.96 8.2 435 138 63 21.6 0.96 21 2.00 8.3 444 141 20.9 0.92 22 1.98 8.3 439 139 19.3 0.88 23 1.96 8.2 435 138 22.9 0.94 22 2.06 8.6 450 153 22.3 0.89 23 2.04 8.5 446 152 20.5 0.86 23 2.03 8.5 441 150 67 23.0 0.78 18 2.06 8.6 450 153 22.4 0.75 19 2.04 8.5 446 152 20.6 0.72 20 2.03 8.5 441 150 24.5 0.76 19 2.13 8.9 460 163 23.7 0.72 20 2.11 8.9 455 162 21.9 0.70 20 2.10 8.8 451 160 71 24.6 0.58 15 2.13 8.9 460 163 23.9 0.56 15 2.11 8.9 455 162 22.1 0.54 16 2.10 8.8 451 160 kW = Total system power Amps = outdoor unit amps (comp.+fan) 26.4 0.75 20 2.06 8.4 388 160 25.6 0.72 21 2.04 8.4 384 158 23.7 0.69 22 2.02 8.3 380 156 71 26.6 0.58 16 2.06 8.4 388 160 25.8 0.55 16 2.04 8.4 384 158 23.8 0.53 17 2.02 8.3 380 156 115ºF Product Specifications Expanded Cooling Data — DSXC160361** / CA*F3743*6A* +TXV / MBVC1600** Low Stage (cont.) 9 10 www.goodmanmfg.com 34.5 0.82 19 2.14 8.1 232 116 33.5 0.78 20 2.12 8.0 230 115 30.9 0.75 20 2.10 8.0 227 114 MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR 1043 1200 1356 59 33.9 0.72 17 2.14 8.1 232 116 32.9 0.68 17 2.12 8.0 230 115 30.4 0.66 18 2.10 8.0 227 114 Airflow MBh S/T ∆T kW 1356 Amps HI PR Lo PR MBh S/T ∆T kW 1200 Amps HI PR Lo PR MBh S/T ∆T 1043 kW Amps HI PR Lo PR 35.5 0.73 18 2.18 8.3 249 120 34.5 0.70 18 2.17 8.2 247 119 31.8 0.67 19 2.15 8.2 244 117 63 35.1 0.60 14 2.18 8.3 249 120 34.1 0.57 15 2.17 8.2 247 119 31.5 0.55 15 2.15 8.2 244 117 38.4 0.55 14 2.25 8.6 253 131 37.3 0.53 15 2.24 8.5 250 129 34.4 0.51 15 2.22 8.4 248 128 67 38.5 0.42 11 2.25 8.6 253 131 37.4 0.40 11 2.24 8.5 250 129 34.5 0.38 12 2.22 8.4 248 128 41.2 0.36 10 2.33 8.9 259 139 40.0 0.34 10 2.31 8.8 256 138 37.0 0.33 11 2.29 8.7 253 136 71 33.7 0.85 19 2.31 8.8 262 119 32.7 0.81 20 2.29 8.7 260 118 30.2 0.78 21 2.27 8.6 257 117 59 33.1 0.74 17 2.31 8.8 262 119 32.2 0.71 17 2.29 8.7 260 118 29.7 0.68 18 2.27 8.6 257 117 34.7 0.76 18 2.36 9.0 282 123 33.7 0.72 19 2.34 8.9 279 122 31.1 0.70 19 2.32 8.8 276 121 63 34.3 0.62 14 2.36 9.0 282 123 33.3 0.59 15 2.34 8.9 279 122 30.8 0.57 15 2.32 8.8 276 121 37.5 0.57 15 2.43 9.3 286 135 36.4 0.55 15 2.41 9.2 283 133 33.6 0.53 16 2.39 9.1 280 132 67 37.6 0.43 11 2.43 9.3 286 135 36.5 0.41 11 2.41 9.2 283 133 33.7 0.40 12 2.39 9.1 280 132 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 40.3 0.37 10 2.51 9.6 292 143 39.1 0.35 11 2.49 9.5 289 142 36.1 0.34 11 2.47 9.4 286 140 71 32.9 0.87 19 2.45 9.5 298 124 31.9 0.83 20 2.43 9.4 295 122 29.5 0.80 21 2.41 9.3 292 121 59 32.3 0.76 17 2.45 9.5 298 124 31.4 0.73 18 2.43 9.4 295 122 29.0 0.70 18 2.41 9.3 292 121 33.8 0.78 18 2.51 9.7 321 127 32.9 0.74 19 2.49 9.6 317 126 30.3 0.71 19 2.47 9.6 314 125 36.6 0.59 15 2.59 10.0 325 139 35.6 0.56 15 2.57 10.0 322 138 32.8 0.54 16 2.55 9.9 319 136 39.3 0.38 10 2.68 10.4 332 148 38.2 0.36 11 2.66 10.3 329 147 35.2 0.35 11 2.63 10.2 326 145 33.0 0.80 18 2.64 10.4 365 131 32.1 0.76 19 2.62 10.3 362 130 29.6 0.74 19 2.60 10.2 358 128 35.7 0.61 15 2.73 10.7 370 143 34.7 0.58 15 2.71 10.6 367 141 32.0 0.56 16 2.68 10.5 363 140 38.4 0.39 10 2.82 11.1 379 152 37.2 0.37 11 2.80 11.0 375 151 34.4 0.36 11 2.78 10.9 371 149 71 30.5 0.93 19 2.69 10.8 367 129 29.6 0.89 20 2.67 10.7 363 128 27.3 0.85 21 2.65 10.6 360 127 59 30.0 0.82 17 2.69 10.8 367 129 29.1 0.78 17 2.67 10.7 363 128 26.9 0.75 18 2.65 10.6 360 127 Shaded area reflects ACCA (TVA) conditions 32.1 0.90 19 2.58 10.1 340 127 31.1 0.85 20 2.56 10.1 336 126 28.7 0.82 21 2.54 10.0 333 124 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 33.5 36.7 31.5 32.7 35.8 0.64 0.44 0.79 0.66 0.46 14 11 17 15 11 2.51 2.59 2.58 2.64 2.73 9.7 10.0 10.1 10.4 10.7 321 325 340 365 370 127 139 127 131 143 32.5 35.6 30.6 31.7 34.8 0.61 0.42 0.75 0.63 0.43 15 11 18 15 12 2.49 2.57 2.56 2.62 2.71 9.6 10.0 10.1 10.3 10.6 317 322 336 362 367 126 138 126 130 141 30.0 32.9 28.3 29.3 32.1 0.59 0.41 0.72 0.61 0.42 16 12 18 16 12 2.47 2.55 2.54 2.60 2.68 9.6 9.9 10.0 10.2 10.5 314 319 333 358 363 125 136 124 128 140 31.4 0.83 18 2.76 11.1 394 133 30.5 0.79 19 2.73 11.0 390 132 28.1 0.76 19 2.71 10.9 387 131 63 31.1 0.68 14 2.76 11.1 394 133 30.2 0.65 15 2.73 11.0 390 132 27.8 0.63 15 2.71 10.9 387 131 34.0 0.63 14 2.85 11.4 400 146 33.0 0.60 15 2.82 11.3 396 144 30.4 0.58 16 2.80 11.2 392 143 67 34.0 0.47 11 2.85 11.4 400 146 33.0 0.45 11 2.82 11.3 396 144 30.5 0.44 12 2.80 11.2 392 143 105ºF 28.2 0.94 18 2.79 11.4 435 133 27.4 0.89 19 2.77 11.3 430 131 25.3 0.86 19 2.74 11.2 426 130 59 27.8 0.82 16 2.79 11.4 435 133 26.9 0.79 16 2.77 11.3 430 131 24.9 0.76 17 2.74 11.2 426 130 29.1 0.84 17 2.85 11.7 467 137 28.2 0.80 17 2.83 11.6 463 135 26.0 0.77 18 2.81 11.5 458 134 63 28.8 0.69 13 2.85 11.7 467 137 27.9 0.66 14 2.83 11.6 463 135 25.8 0.63 14 2.81 11.5 458 134 31.5 0.63 14 2.95 12.1 474 149 30.5 0.61 14 2.93 12.0 469 148 28.2 0.58 14 2.90 11.9 465 146 67 31.5 0.48 10 2.95 12.1 474 149 30.6 0.45 11 2.93 12.0 469 148 28.2 0.44 11 2.90 11.9 465 146 33.8 0.41 9 3.05 12.6 484 159 32.8 0.39 10 3.03 12.4 480 157 30.3 0.38 10 3.00 12.3 475 156 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 36.4 0.40 10 2.95 11.9 409 155 35.4 0.39 10 2.92 11.7 405 154 32.7 0.37 11 2.90 11.6 401 152 71 - 115ºF Product Specifications Expanded Cooling Data — DSXC160361** / CA*F3743*6A* +TXV / MBVC1600** High Stage SS-DSXC16 SS-DSXC16 www.goodmanmfg.com 35.7 0.94 23 2.14 8.1 232 116 34.7 0.90 24 2.12 8.0 230 115 32.0 0.86 24 2.10 8.0 227 114 MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR MBh S/T ∆T kW Amps HI PR Lo PR 1043 1200 1356 59 35.1 0.90 21 2.14 8.1 232 116 34.1 0.85 22 2.12 8.0 230 115 31.4 0.82 23 2.10 8.0 227 114 Airflow MBh S/T ∆T kW 1356 Amps HI PR Lo PR MBh S/T ∆T kW 1200 Amps HI PR Lo PR MBh S/T ∆T 1043 kW Amps HI PR Lo PR 36.4 0.91 22 2.18 8.3 249 120 35.3 0.86 23 2.17 8.2 247 119 32.6 0.83 24 2.15 8.2 244 117 63 35.9 0.84 20 2.18 8.3 249 120 34.8 0.80 21 2.17 8.2 247 119 32.1 0.77 22 2.15 8.2 244 117 38.1 0.82 21 2.25 8.6 253 131 37.0 0.78 22 2.24 8.5 250 129 34.2 0.75 23 2.22 8.4 248 128 67 38.3 0.68 18 2.25 8.6 253 131 37.2 0.65 19 2.24 8.5 250 129 34.3 0.63 19 2.22 8.4 248 128 40.7 0.66 18 2.33 8.9 259 139 39.5 0.63 19 2.31 8.8 256 138 36.4 0.61 20 2.29 8.7 253 136 71 41.0 0.51 14 2.33 8.9 259 139 39.8 0.49 15 2.31 8.8 256 138 36.7 0.47 15 2.29 8.7 253 136 34.9 0.97 23 2.31 8.8 262 119 33.9 0.93 24 2.29 8.7 260 118 31.3 0.89 25 2.27 8.6 257 117 59 34.3 0.93 22 2.31 8.8 262 119 33.3 0.88 23 2.29 8.7 260 118 30.7 0.85 23 2.27 8.6 257 117 35.6 0.94 23 2.36 9.0 282 123 34.5 0.90 24 2.34 8.9 279 122 31.9 0.86 24 2.32 8.8 276 121 63 35.0 0.87 21 2.36 9.0 282 123 34.0 0.83 22 2.34 8.9 279 122 31.4 0.80 22 2.32 8.8 276 121 37.2 0.85 21 2.43 9.3 286 135 36.1 0.81 22 2.41 9.2 283 133 33.4 0.78 23 2.39 9.1 280 132 67 37.4 0.71 18 2.43 9.3 286 135 36.3 0.68 19 2.41 9.2 283 133 33.5 0.65 19 2.39 9.1 280 132 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 39.7 0.69 19 2.51 9.6 292 143 38.6 0.66 19 2.49 9.5 289 142 35.6 0.63 20 2.47 9.4 286 140 71 40.0 0.53 14 2.51 9.6 292 143 38.8 0.50 15 2.49 9.5 289 142 35.8 0.49 15 2.47 9.4 286 140 34.0 1.00 23 2.45 9.5 298 124 33.1 0.95 24 2.43 9.4 295 122 30.5 0.92 25 2.41 9.3 292 121 59 33.5 0.95 22 2.45 9.5 298 124 32.5 0.91 23 2.43 9.4 295 122 30.0 0.87 23 2.41 9.3 292 121 34.7 0.96 23 2.51 9.7 321 127 33.7 0.92 24 2.49 9.6 317 126 31.1 0.89 24 2.47 9.6 314 125 36.3 0.87 21 2.59 10.0 325 139 35.3 0.83 22 2.57 10.0 322 138 32.6 0.80 23 2.55 9.9 319 136 38.8 0.70 19 2.68 10.4 332 148 37.6 0.67 19 2.66 10.3 329 147 34.7 0.65 20 2.63 10.2 326 145 33.9 0.99 23 2.64 10.4 365 131 32.9 0.95 24 2.62 10.3 362 130 30.3 0.91 24 2.60 10.2 358 128 35.5 0.90 22 2.73 10.7 370 143 34.4 0.86 23 2.71 10.6 367 141 31.8 0.82 23 2.68 10.5 363 140 37.8 0.73 19 2.82 11.1 379 152 36.7 0.69 20 2.80 11.0 375 151 33.9 0.67 20 2.78 10.9 371 149 71 38.1 0.56 14 2.82 11.1 379 152 37.0 0.53 15 2.80 11.0 375 151 34.1 0.52 16 2.78 10.9 371 149 31.6 1.00 21 2.69 10.8 367 129 30.6 1.00 23 2.67 10.7 363 128 28.3 0.98 24 2.65 10.6 360 127 59 31.0 1.00 21 2.69 10.8 367 129 30.1 0.97 22 2.67 10.7 363 128 27.8 0.94 23 2.65 10.6 360 127 Shaded area reflects AHRI (TVA) conditions 33.2 1.00 23 2.58 10.1 340 127 32.2 0.98 24 2.56 10.1 336 126 29.8 0.95 25 2.54 10.0 333 124 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 34.2 36.5 39.0 32.6 33.4 35.6 0.89 0.73 0.54 1.00 0.92 0.75 21 18 14 22 21 18 2.51 2.59 2.68 2.58 2.64 2.73 9.7 10.0 10.4 10.1 10.4 10.7 321 325 332 340 365 370 127 139 148 127 131 143 33.2 35.5 37.9 31.7 32.4 34.6 0.85 0.69 0.52 0.94 0.88 0.71 22 19 15 23 22 19 2.49 2.57 2.66 2.56 2.62 2.71 9.6 10.0 10.3 10.1 10.3 10.6 317 322 329 336 362 367 126 138 147 126 130 141 30.6 32.7 35.0 29.3 29.9 31.9 0.82 0.67 0.50 0.90 0.85 0.69 22 19 15 23 22 19 2.47 2.55 2.63 2.54 2.60 2.68 9.6 9.9 10.2 10.0 10.2 10.5 314 319 326 333 358 363 125 136 145 124 128 140 32.2 1.00 22 2.76 11.1 394 133 31.2 0.98 24 2.73 11.0 390 132 28.8 0.95 24 2.71 10.9 387 131 63 31.7 0.96 21 2.76 11.1 394 133 30.8 0.91 21 2.73 11.0 390 132 28.4 0.88 22 2.71 10.9 387 131 33.7 0.93 21 2.85 11.4 400 146 32.7 0.89 22 2.82 11.3 396 144 30.2 0.86 23 2.80 11.2 392 143 67 33.9 0.78 18 2.85 11.4 400 146 32.9 0.74 19 2.82 11.3 396 144 30.3 0.72 19 2.80 11.2 392 143 105ºF 29.2 1.00 20 2.79 11.4 435 133 28.4 1.00 22 2.77 11.3 430 131 26.2 0.99 23 2.74 11.2 426 130 59 28.7 1.00 19 2.79 11.4 435 133 27.9 0.98 21 2.77 11.3 430 131 25.7 0.95 21 2.74 11.2 426 130 29.8 1.00 20 2.85 11.7 467 137 28.9 0.99 22 2.83 11.6 463 135 26.7 0.96 22 2.81 11.5 458 134 63 29.4 0.96 19 2.85 11.7 467 137 28.5 0.92 20 2.83 11.6 463 135 26.3 0.89 21 2.81 11.5 458 134 31.2 0.94 20 2.95 12.1 474 149 30.3 0.89 21 2.93 12.0 469 148 28.0 0.86 21 2.90 11.9 465 146 67 31.4 0.78 17 2.95 12.1 474 149 30.4 0.75 17 2.93 12.0 469 148 28.1 0.72 18 2.90 11.9 465 146 33.3 0.76 17 3.05 12.6 484 159 32.3 0.73 18 3.03 12.4 480 157 29.8 0.70 18 3.00 12.3 475 156 71 33.5 0.59 13 3.05 12.6 484 159 32.5 0.56 14 3.03 12.4 480 157 30.0 0.54 14 3.00 12.3 475 156 kW = Total system power Amps = outdoor unit amps (comp.+fan) 35.9 0.75 18 2.95 11.9 409 155 34.9 0.72 19 2.92 11.7 405 154 32.2 0.69 20 2.90 11.6 401 152 71 36.2 0.58 14 2.95 11.9 409 155 35.1 0.55 15 2.92 11.7 405 154 32.4 0.53 15 2.90 11.6 401 152 115ºF Product Specifications Expanded Cooling Data — DSXC160361** / CA*F3743*6A* +TXV / MBVC1600** High Stage (cont.) 11 12 www.goodmanmfg.com 34.9 0.84 22 2.06 9.9 218 108 33.9 0.81 23 2.04 9.8 216 107 31.3 0.78 23 1.99 9.6 209 104 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 963 1100 1238 59 34.3 0.74 19 2.04 9.8 216 107 33.3 0.71 20 2.02 9.7 214 106 30.7 0.68 20 1.97 9.5 207 102 Airflow MBh S/T ∆T kW 1238 Amps HI PR LO PR MBh S/T ∆T kW 1100 Amps HI PR LO PR MBh S/T ∆T 963 kW Amps HI PR LO PR 35.9 0.76 20 2.10 10.0 235 115 34.9 0.72 21 2.08 10.0 232 114 32.2 0.69 21 2.03 9.7 225 110 63 35.5 0.62 16 2.08 10.0 232 114 34.5 0.59 17 2.07 9.9 230 112 31.9 0.57 17 2.02 9.7 223 109 38.9 0.57 17 2.17 10.3 248 125 37.7 0.55 17 2.15 10.2 245 124 34.8 0.53 17 2.10 10.0 238 120 67 38.9 0.43 12 2.15 10.2 245 124 37.8 0.41 13 2.13 10.2 243 123 34.9 0.40 13 2.08 9.9 235 119 41.7 0.37 11 2.24 10.6 258 133 40.5 0.35 12 2.22 10.6 256 132 37.4 0.34 12 2.17 10.3 248 128 71 34.1 0.88 22 2.22 10.5 245 114 33.1 0.84 23 2.20 10.4 242 113 30.5 0.81 23 2.14 10.2 235 109 59 33.5 0.77 19 2.20 10.4 242 113 32.5 0.73 20 2.18 10.4 240 112 30.0 0.71 20 2.13 10.1 232 108 35.1 0.78 20 2.27 10.7 263 121 34.1 0.75 21 2.25 10.6 261 120 31.4 0.72 22 2.19 10.4 253 116 63 34.7 0.64 17 2.25 10.6 261 120 33.7 0.61 17 2.23 10.6 258 119 31.1 0.59 18 2.17 10.3 250 115 38.0 0.59 17 2.34 11.0 278 132 36.9 0.57 17 2.32 10.9 275 131 34.0 0.55 18 2.26 10.7 267 127 67 38.0 0.45 13 2.32 10.9 275 131 36.9 0.43 13 2.30 10.9 272 130 34.1 0.41 13 2.24 10.6 264 126 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 40.7 0.38 12 2.42 11.4 290 141 39.6 0.36 12 2.40 11.3 287 139 36.5 0.35 12 2.34 11.0 278 135 71 33.3 0.90 22 2.36 11.3 278 118 32.3 0.86 23 2.34 11.2 275 117 29.8 0.83 24 2.28 10.9 267 114 59 32.7 0.79 19 2.34 11.2 275 117 31.7 0.75 20 2.32 11.1 273 116 29.3 0.73 20 2.26 10.8 264 113 34.2 0.80 20 2.41 11.5 299 126 33.2 0.77 21 2.39 11.4 296 125 30.7 0.74 22 2.33 11.2 287 121 37.1 0.61 17 2.49 11.8 316 137 36.0 0.58 17 2.47 11.8 313 136 33.2 0.56 18 2.41 11.5 304 132 39.8 0.39 12 2.57 12.2 330 146 38.6 0.37 12 2.55 12.1 326 145 35.6 0.36 12 2.49 11.8 317 141 33.4 0.83 21 2.54 12.2 341 132 32.4 0.79 21 2.52 12.1 338 131 29.9 0.76 22 2.45 11.8 327 127 36.2 0.63 17 2.62 12.6 360 144 35.1 0.60 18 2.60 12.5 356 143 32.4 0.58 18 2.54 12.2 346 139 38.8 0.40 12 2.71 13.0 375 154 37.7 0.38 12 2.69 12.9 372 152 34.8 0.37 12 2.62 12.6 361 148 71 30.8 0.96 22 2.59 12.6 356 130 29.9 0.92 23 2.57 12.5 353 129 27.6 0.88 23 2.50 12.2 342 125 59 30.3 0.85 19 2.57 12.5 353 129 29.4 0.81 20 2.55 12.4 349 128 27.2 0.78 20 2.48 12.1 339 124 Shaded area reflects ACCA (TVA) conditions 32.4 0.93 22 2.48 11.9 317 124 31.5 0.88 23 2.46 11.9 314 123 29.1 0.85 24 2.40 11.6 304 119 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 33.9 37.1 31.9 33.1 36.2 0.66 0.46 0.82 0.68 0.47 17 13 19 17 13 2.39 2.47 2.46 2.52 2.60 11.4 11.8 11.9 12.1 12.5 296 313 314 337 356 125 136 123 131 143 32.9 36.1 31.0 32.1 35.2 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 2.37 2.45 2.44 2.50 2.58 11.3 11.7 11.8 12.0 12.4 293 310 310 334 353 123 135 122 130 142 30.4 33.3 28.6 29.6 32.5 0.61 0.42 0.75 0.63 0.43 18 13 20 18 13 2.31 2.39 2.38 2.43 2.51 11.1 11.4 11.5 11.7 12.1 285 300 301 324 342 120 131 118 126 137 31.7 0.86 20 2.65 12.9 383 139 30.8 0.82 21 2.63 12.8 380 137 28.4 0.79 21 2.56 12.5 368 133 63 31.4 0.71 16 2.63 12.8 380 137 30.5 0.67 17 2.60 12.7 376 136 28.2 0.65 17 2.54 12.4 365 132 34.4 0.65 17 2.74 13.3 405 151 33.3 0.62 17 2.71 13.2 401 150 30.8 0.60 18 2.64 12.8 389 145 67 34.4 0.49 13 2.71 13.2 401 150 33.4 0.47 13 2.69 13.0 397 148 30.8 0.45 13 2.62 12.7 385 144 105ºF 28.6 0.97 21 2.68 13.3 394 135 27.7 0.93 21 2.66 13.2 390 133 25.6 0.89 22 2.59 12.8 378 129 59 28.1 0.85 18 2.66 13.2 390 133 27.3 0.81 19 2.64 13.1 386 132 25.2 0.78 19 2.57 12.7 374 128 29.4 0.87 19 2.74 13.6 424 143 28.5 0.83 20 2.72 13.4 420 142 26.3 0.80 20 2.65 13.1 407 138 63 29.1 0.71 15 2.72 13.4 419 142 28.3 0.68 16 2.70 13.3 415 141 26.1 0.66 16 2.63 13.0 403 136 31.8 0.66 16 2.83 14.0 447 157 30.9 0.63 16 2.81 13.8 443 155 28.5 0.60 16 2.74 13.5 430 150 67 31.9 0.49 12 2.81 13.8 443 155 31.0 0.47 12 2.79 13.7 439 153 28.6 0.45 12 2.71 13.4 425 149 34.2 0.42 11 2.93 14.4 467 167 33.2 0.40 11 2.91 14.3 462 165 30.6 0.39 11 2.83 14.0 448 160 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 36.9 0.42 11 2.83 13.7 422 161 35.8 0.40 12 2.81 13.6 418 160 33.0 0.39 12 2.73 13.3 406 155 71 - 115ºF Product Specifications Expanded Cooling Data — DSXC160481B* / CA*F4860*6**+TXV/MBVC2000** Low stage SS-DSXC16 SS-DSXC16 www.goodmanmfg.com 36.1 0.97 26 2.09 10.0 222 110 35.1 0.93 27 2.07 9.9 220 109 32.4 0.89 28 2.02 9.7 214 106 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 963 1100 1238 59 35.5 0.93 24 2.07 9.9 220 109 34.5 0.88 25 2.06 9.9 218 108 31.8 0.85 26 2.01 9.6 211 105 Airflow MBh S/T ∆T kW 1238 Amps HI PR LO PR MBh S/T ∆T kW 1100 Amps HI PR LO PR MBh S/T ∆T 963 kW Amps HI PR LO PR 36.8 0.94 26 2.13 10.2 239 117 35.7 0.89 27 2.12 10.1 237 116 33.0 0.86 27 2.07 9.9 230 112 63 36.3 0.87 23 2.12 10.1 237 116 35.2 0.83 24 2.10 10.0 235 115 32.5 0.80 25 2.05 9.8 228 111 38.6 0.85 24 2.20 10.5 253 128 37.4 0.81 25 2.19 10.4 250 126 34.6 0.78 26 2.13 10.2 243 123 67 38.8 0.71 20 2.19 10.4 250 126 37.6 0.67 21 2.17 10.3 248 125 34.7 0.65 22 2.11 10.1 240 121 41.1 0.69 21 2.28 10.8 264 136 39.9 0.65 22 2.26 10.7 261 135 36.9 0.63 22 2.20 10.5 253 131 71 41.4 0.53 16 2.26 10.7 261 135 40.2 0.50 17 2.24 10.6 258 133 37.1 0.49 17 2.18 10.4 251 129 35.3 1.00 26 2.25 10.7 249 116 34.3 0.96 27 2.24 10.6 247 115 31.6 0.93 28 2.18 10.4 240 112 59 34.7 0.96 25 2.24 10.6 247 115 33.7 0.92 26 2.22 10.5 245 114 31.1 0.88 26 2.16 10.3 237 110 36.0 0.97 26 2.30 10.9 268 124 34.9 0.93 27 2.28 10.8 266 122 32.2 0.89 27 2.23 10.6 258 119 63 35.4 0.90 24 2.28 10.8 266 122 34.4 0.86 25 2.27 10.7 263 121 31.7 0.83 25 2.21 10.5 255 118 37.7 0.88 25 2.38 11.2 284 135 36.6 0.84 26 2.36 11.1 281 134 33.8 0.81 26 2.30 10.9 272 130 67 37.9 0.73 21 2.36 11.1 281 134 36.8 0.70 21 2.34 11.0 278 132 33.9 0.67 22 2.28 10.8 270 128 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 40.2 0.71 21 2.46 11.6 296 144 39.0 0.68 22 2.44 11.5 293 142 36.0 0.65 22 2.38 11.2 284 138 71 40.5 0.55 16 2.44 11.5 293 142 39.3 0.52 17 2.42 11.4 290 141 36.3 0.50 17 2.36 11.1 281 137 34.4 1.00 26 2.40 11.5 284 121 33.4 0.98 28 2.38 11.4 281 120 30.9 0.95 28 2.32 11.1 273 116 59 33.8 1.00 25 2.38 11.4 281 120 32.9 0.94 26 2.36 11.3 278 118 30.3 0.91 26 2.30 11.0 270 115 35.1 1.00 26 2.45 11.7 305 128 34.1 0.95 27 2.43 11.6 302 127 31.5 0.92 28 2.37 11.3 293 123 36.8 0.90 25 2.53 12.0 322 140 35.7 0.86 26 2.51 11.9 319 139 32.9 0.83 26 2.45 11.7 310 135 39.2 0.73 21 2.62 12.4 336 149 38.1 0.70 22 2.60 12.3 333 148 35.1 0.67 23 2.53 12.0 323 143 34.2 1.00 25 2.58 12.4 348 135 33.3 0.98 27 2.56 12.3 344 134 30.7 0.95 28 2.50 12.0 334 130 35.9 0.93 25 2.67 12.8 367 147 34.8 0.89 26 2.65 12.7 364 146 32.1 0.85 26 2.58 12.4 353 141 38.3 0.75 21 2.76 13.2 383 157 37.2 0.72 22 2.74 13.1 379 155 34.3 0.69 23 2.67 12.8 368 151 71 38.5 0.58 17 2.74 13.1 379 155 37.4 0.55 17 2.71 13.0 375 154 34.5 0.53 18 2.64 12.7 364 149 31.9 1.00 24 2.63 12.8 364 133 31.0 1.00 26 2.61 12.7 360 132 28.6 1.00 27 2.55 12.4 349 128 59 31.4 1.00 23 2.61 12.7 360 132 30.5 1.00 25 2.59 12.6 356 130 28.1 0.97 26 2.52 12.3 346 126 Shaded area reflects AHRI (TVA) conditions 33.6 1.00 25 2.53 12.1 323 127 32.6 1.00 27 2.50 12.0 320 126 30.1 0.98 28 2.44 11.8 310 122 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 34.6 37.0 39.5 33.0 33.7 36.1 0.92 0.75 0.56 1.00 0.95 0.78 24 21 16 25 24 21 2.43 2.51 2.60 2.50 2.56 2.65 11.6 11.9 12.3 12.0 12.3 12.7 302 319 333 320 344 364 127 139 148 126 134 146 33.6 35.9 38.4 32.1 32.8 35.0 0.88 0.72 0.54 0.97 0.91 0.74 25 21 17 26 25 22 2.41 2.49 2.57 2.48 2.54 2.62 11.5 11.8 12.2 12.0 12.2 12.6 299 316 330 317 341 360 126 137 146 124 132 144 31.0 33.1 35.4 29.6 30.2 32.3 0.85 0.69 0.52 0.93 0.88 0.71 25 22 17 26 25 22 2.35 2.43 2.51 2.42 2.48 2.56 11.2 11.6 11.9 11.7 11.9 12.3 290 307 320 307 331 349 122 133 142 121 128 140 32.5 1.00 24 2.69 13.1 391 141 31.6 1.00 26 2.67 13.0 387 140 29.2 0.98 27 2.60 12.7 376 136 63 32.1 1.00 24 2.67 13.0 387 140 31.1 0.94 25 2.65 12.9 384 139 28.7 0.91 25 2.58 12.6 372 134 34.1 0.96 24 2.78 13.5 413 154 33.1 0.92 25 2.76 13.4 409 153 30.5 0.89 26 2.69 13.0 397 148 67 34.2 0.81 20 2.76 13.4 409 153 33.3 0.77 21 2.74 13.3 405 151 30.7 0.74 22 2.67 12.9 393 147 105ºF 29.6 1.00 22 2.73 13.5 402 137 28.7 1.00 24 2.70 13.4 398 136 26.5 1.00 25 2.64 13.1 386 132 59 29.1 1.00 22 2.70 13.4 398 136 28.2 1.00 24 2.68 13.3 394 135 26.0 0.98 24 2.61 12.9 382 131 30.1 1.00 22 2.79 13.8 432 146 29.3 1.00 24 2.77 13.7 428 145 27.0 0.99 26 2.69 13.3 415 140 63 29.7 1.00 22 2.77 13.7 428 145 28.8 0.95 23 2.74 13.6 424 143 26.6 0.92 23 2.67 13.2 411 139 31.6 0.97 23 2.88 14.2 456 160 30.6 0.93 24 2.86 14.1 452 158 28.3 0.89 24 2.79 13.7 438 153 67 31.7 0.81 19 2.86 14.1 452 158 30.8 0.77 20 2.83 14.0 447 157 28.4 0.75 20 2.76 13.6 434 152 33.7 0.79 20 2.98 14.7 476 170 32.7 0.75 21 2.96 14.6 471 168 30.2 0.72 21 2.88 14.2 457 163 71 33.9 0.61 15 2.96 14.6 471 168 32.9 0.58 16 2.93 14.4 467 167 30.4 0.56 16 2.86 14.1 453 162 kW = Total system power Amps = outdoor unit amps (comp.+fan) 36.4 0.78 21 2.88 13.9 431 164 35.3 0.75 22 2.85 13.8 427 163 32.6 0.72 22 2.78 13.5 414 158 71 36.6 0.60 16 2.85 13.8 427 163 35.5 0.57 17 2.83 13.7 422 161 32.8 0.55 17 2.76 13.4 410 156 115ºF Product Specifications Expanded Cooling Data — DSXC160481B* / CA*F4860*6**+TXV/MBVC2000** Low stage (cont.) 13 14 www.goodmanmfg.com 46.8 0.84 20 3.06 14.7 237 105 45.5 0.81 21 3.03 14.6 235 104 42.0 0.78 21 2.96 14.3 228 101 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 1400 1600 1800 59 46.1 0.74 17 3.03 14.6 235 104 44.7 0.71 18 3.01 14.5 233 103 41.3 0.68 19 2.93 14.2 226 100 Airflow MBh S/T ∆T kW 1800 Amps HI PR LO PR MBh S/T ∆T kW 1600 Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR 48.2 0.76 19 3.12 15.0 255 112 46.8 0.72 19 3.10 14.9 253 111 43.2 0.69 20 3.02 14.5 245 108 63 47.7 0.62 15 3.10 14.9 253 111 46.3 0.59 16 3.07 14.8 250 110 42.8 0.57 16 3.00 14.4 243 106 52.2 0.57 15 3.22 15.4 270 122 50.7 0.55 16 3.20 15.3 267 121 46.8 0.53 16 3.12 14.9 259 117 67 52.3 0.43 11 3.19 15.3 267 121 50.8 0.41 12 3.17 15.1 264 120 46.9 0.40 12 3.09 14.8 256 116 56.0 0.37 11 3.33 15.9 281 130 54.4 0.35 11 3.30 15.7 278 129 50.2 0.34 11 3.22 15.4 270 125 71 45.7 0.88 20 3.29 15.7 266 111 44.4 0.84 21 3.27 15.5 264 110 41.0 0.81 22 3.19 15.2 256 107 59 45.0 0.77 18 3.27 15.5 264 110 43.7 0.73 18 3.24 15.4 261 109 40.3 0.71 19 3.16 15.1 253 106 47.1 0.78 19 3.37 16.0 287 118 45.7 0.75 20 3.34 15.9 284 117 42.2 0.72 20 3.26 15.5 275 114 63 46.6 0.64 15 3.34 15.9 284 117 45.3 0.61 16 3.31 15.7 281 116 41.8 0.59 16 3.23 15.4 272 112 51.0 0.59 15 3.48 16.4 303 129 49.5 0.57 16 3.45 16.3 300 128 45.7 0.55 16 3.36 15.9 291 124 67 51.1 0.45 12 3.45 16.3 300 128 49.6 0.43 12 3.42 16.2 297 127 45.8 0.41 12 3.33 15.8 288 123 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 54.7 0.38 11 3.59 16.9 316 138 53.1 0.36 11 3.56 16.8 312 136 49.0 0.35 11 3.47 16.4 303 132 71 44.7 0.90 20 3.51 16.8 303 116 43.4 0.86 21 3.48 16.7 300 114 40.0 0.83 22 3.39 16.3 291 111 59 43.9 0.79 18 3.48 16.7 300 114 42.6 0.75 18 3.45 16.5 297 113 39.4 0.73 19 3.36 16.1 288 110 46.0 0.80 19 3.58 17.1 326 123 44.6 0.77 20 3.55 17.0 323 122 41.2 0.74 20 3.46 16.6 313 118 49.8 0.61 15 3.70 17.6 344 134 48.3 0.58 16 3.67 17.5 341 133 44.6 0.56 16 3.58 17.1 331 129 53.4 0.39 11 3.83 18.2 359 143 51.9 0.37 11 3.79 18.0 355 142 47.9 0.36 11 3.70 17.6 345 137 44.9 0.83 19 3.77 18.1 371 129 43.6 0.79 20 3.74 18.0 368 128 40.2 0.76 20 3.65 17.6 356 124 48.6 0.63 16 3.90 18.6 392 141 47.1 0.60 16 3.87 18.5 388 140 43.5 0.58 16 3.77 18.1 376 135 52.1 0.40 11 4.03 19.3 409 150 50.6 0.38 11 4.00 19.1 405 149 46.7 0.37 11 3.90 18.6 393 144 71 41.4 0.96 20 3.85 18.7 388 127 40.2 0.92 21 3.82 18.6 384 126 37.1 0.88 22 3.72 18.1 373 122 59 40.7 0.85 18 3.82 18.6 384 126 39.5 0.81 18 3.78 18.4 380 125 36.5 0.78 19 3.69 18.0 369 121 Shaded area reflects ACCA (TVA) conditions 43.6 0.93 21 3.69 17.8 345 121 42.3 0.88 21 3.66 17.6 342 120 39.0 0.85 22 3.57 17.2 331 117 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 45.5 49.9 42.8 44.4 48.7 0.66 0.46 0.82 0.68 0.47 15 12 18 15 12 3.55 3.67 3.66 3.74 3.87 17.0 17.5 17.6 18.0 18.5 323 341 341 367 388 122 133 120 128 140 44.2 48.4 41.6 43.1 47.2 0.63 0.44 0.78 0.65 0.45 16 12 19 16 12 3.52 3.64 3.63 3.71 3.83 16.9 17.3 17.5 17.8 18.4 319 337 338 364 384 120 132 119 127 138 40.8 44.7 38.4 39.8 43.6 0.61 0.42 0.75 0.63 0.43 16 12 19 16 12 3.44 3.55 3.54 3.62 3.74 16.5 16.9 17.1 17.4 17.9 310 327 328 353 373 117 128 115 123 134 42.6 0.86 19 3.94 19.1 418 135 41.4 0.82 20 3.90 19.0 413 134 38.2 0.79 20 3.80 18.5 401 130 63 42.2 0.71 15 3.90 19.0 413 134 41.0 0.67 16 3.87 18.8 409 133 37.8 0.65 16 3.77 18.4 397 129 46.1 0.65 15 4.07 19.7 441 148 44.8 0.62 16 4.03 19.5 437 146 41.3 0.60 16 3.93 19.1 423 142 67 46.2 0.49 12 4.03 19.5 437 146 44.9 0.47 12 4.00 19.4 432 145 41.4 0.45 12 3.90 18.9 419 140 105ºF 38.3 0.97 19 3.99 19.7 429 132 37.2 0.93 20 3.95 19.5 424 130 34.4 0.89 20 3.85 19.1 412 126 59 37.7 0.85 16 3.95 19.5 424 130 36.6 0.81 17 3.92 19.4 420 129 33.8 0.78 17 3.82 18.9 408 125 39.5 0.87 17 4.08 20.1 461 140 38.3 0.83 18 4.04 20.0 457 139 35.4 0.80 19 3.94 19.5 443 134 63 39.1 0.71 14 4.04 20.0 457 139 37.9 0.68 15 4.01 19.8 452 137 35.0 0.66 15 3.90 19.3 439 133 42.7 0.66 14 4.21 20.7 487 153 41.5 0.63 15 4.18 20.5 482 151 38.3 0.60 15 4.07 20.0 468 147 67 42.8 0.49 11 4.18 20.5 482 151 41.6 0.47 11 4.14 20.4 478 150 38.4 0.45 11 4.04 19.9 463 145 45.9 0.42 10 4.36 21.4 508 163 44.5 0.40 10 4.32 21.2 503 161 41.1 0.39 10 4.21 20.7 488 156 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 49.5 0.42 11 4.21 20.3 460 157 48.1 0.40 11 4.17 20.2 455 156 44.4 0.39 11 4.06 19.7 442 151 71 - 115ºF Product Specifications Expanded Cooling Data — DSXC160481B* / CA*F4860*6**+TXV/MBVC2000** High stage SS-DSXC16 SS-DSXC16 www.goodmanmfg.com 48.5 0.97 24 3.11 14.9 242 107 47.1 0.93 25 3.08 14.8 240 106 43.5 0.89 25 3.01 14.5 233 103 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 1400 1600 1800 59 47.7 0.93 23 3.08 14.8 240 106 46.3 0.88 24 3.06 14.7 237 105 42.7 0.85 24 2.98 14.4 230 102 Airflow MBh S/T ∆T kW 1800 Amps HI PR LO PR MBh S/T ∆T kW 1600 Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR 49.4 0.94 24 3.17 15.2 261 114 48.0 0.89 25 3.15 15.1 258 113 44.3 0.86 25 3.07 14.7 250 110 63 48.7 0.87 22 3.15 15.1 258 113 47.3 0.83 23 3.12 15.0 255 112 43.6 0.80 23 3.05 14.6 248 109 51.8 0.85 22 3.27 15.6 275 125 50.3 0.81 23 3.25 15.5 272 123 46.4 0.78 24 3.17 15.1 264 120 67 52.0 0.71 19 3.25 15.5 272 123 50.5 0.67 20 3.22 15.4 270 122 46.6 0.65 20 3.14 15.0 262 119 55.2 0.69 19 3.38 16.1 287 133 53.6 0.65 20 3.35 16.0 284 131 49.5 0.63 21 3.27 15.6 276 128 71 55.6 0.53 15 3.35 16.0 284 131 54.0 0.50 16 3.33 15.9 281 130 49.9 0.49 16 3.24 15.5 273 126 47.4 1.00 24 3.35 15.9 272 113 46.0 0.96 25 3.32 15.8 269 112 42.5 0.93 26 3.24 15.4 261 109 59 46.6 0.96 23 3.32 15.8 269 112 45.2 0.92 24 3.29 15.7 266 111 41.7 0.88 24 3.21 15.3 258 108 48.3 0.97 24 3.42 16.2 292 121 46.9 0.93 25 3.39 16.1 289 119 43.3 0.89 25 3.31 15.7 281 116 63 47.6 0.90 22 3.39 16.1 289 119 46.2 0.86 23 3.37 16.0 287 118 42.6 0.83 23 3.28 15.6 278 115 50.6 0.88 23 3.53 16.7 309 132 49.1 0.84 24 3.51 16.5 306 130 45.3 0.81 24 3.42 16.2 296 127 67 50.8 0.73 19 3.51 16.5 306 130 49.4 0.70 20 3.48 16.4 303 129 45.6 0.67 20 3.39 16.0 294 125 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 54.0 0.71 20 3.65 17.2 322 140 52.4 0.68 20 3.62 17.1 319 139 48.4 0.65 21 3.53 16.7 309 135 71 54.3 0.55 15 3.62 17.1 319 139 52.8 0.52 16 3.59 16.9 316 138 48.7 0.50 16 3.50 16.5 306 133 46.2 1.00 24 3.56 17.0 309 118 44.9 0.98 25 3.53 16.9 306 117 41.4 0.95 26 3.45 16.5 297 113 59 45.5 1.00 23 3.53 16.9 306 117 44.1 0.94 24 3.51 16.8 303 116 40.7 0.91 24 3.42 16.4 294 112 47.1 1.00 24 3.64 17.4 332 125 45.8 0.95 25 3.61 17.3 329 124 42.2 0.92 25 3.52 16.9 319 120 49.4 0.90 23 3.76 17.9 351 137 47.9 0.86 24 3.73 17.8 348 136 44.2 0.83 24 3.64 17.3 337 132 52.7 0.73 20 3.89 18.5 366 146 51.1 0.70 20 3.86 18.3 363 144 47.2 0.67 21 3.76 17.9 352 140 46.0 1.00 23 3.84 18.4 379 132 44.7 0.98 25 3.81 18.3 375 130 41.2 0.95 26 3.71 17.8 364 127 48.2 0.93 23 3.97 18.9 400 144 46.8 0.89 24 3.93 18.8 396 142 43.2 0.85 24 3.83 18.3 384 138 51.4 0.75 20 4.10 19.6 417 153 49.9 0.72 21 4.07 19.4 413 152 46.0 0.69 21 3.96 18.9 401 147 71 51.8 0.58 15 4.07 19.4 413 152 50.2 0.55 16 4.03 19.3 409 150 46.4 0.53 16 3.93 18.8 397 146 42.9 1.00 22 3.92 19.0 396 130 41.6 1.00 24 3.88 18.9 392 129 38.4 1.00 25 3.78 18.4 380 125 59 42.1 1.00 22 3.88 18.9 392 129 40.9 1.00 24 3.85 18.7 388 127 37.8 0.97 24 3.75 18.3 376 123 Shaded area reflects AHRI (TVA) conditions 45.1 1.00 23 3.75 18.0 352 124 43.8 1.00 25 3.72 17.9 348 123 40.4 0.98 26 3.63 17.5 338 119 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 46.4 49.6 53.0 44.3 45.3 48.4 0.92 0.75 0.56 1.00 0.95 0.78 22 19 15 23 22 19 3.61 3.73 3.86 3.72 3.81 3.93 17.3 17.8 18.3 17.9 18.3 18.8 329 348 363 348 375 396 124 136 144 123 130 142 45.1 48.2 51.5 43.1 44.0 47.0 0.88 0.72 0.54 0.97 0.91 0.74 23 20 16 24 23 20 3.58 3.70 3.83 3.69 3.77 3.90 17.1 17.6 18.2 17.8 18.1 18.7 326 344 359 345 371 392 123 134 143 121 129 141 41.6 44.5 47.5 39.7 40.6 43.4 0.85 0.69 0.52 0.93 0.88 0.71 23 20 16 24 23 20 3.49 3.61 3.73 3.60 3.68 3.80 16.7 17.2 17.7 17.3 17.7 18.2 316 334 348 335 360 380 119 130 139 118 125 137 43.7 1.00 22 4.00 19.4 426 138 42.4 1.00 24 3.97 19.3 422 137 39.2 0.98 25 3.87 18.8 409 133 63 43.0 1.00 22 3.97 19.3 422 137 41.8 0.94 23 3.94 19.1 418 135 38.6 0.91 23 3.84 18.7 405 131 45.8 0.96 23 4.14 20.0 450 151 44.4 0.92 23 4.10 19.8 445 149 41.0 0.89 24 4.00 19.4 432 145 67 46.0 0.81 19 4.10 19.8 445 149 44.7 0.77 20 4.07 19.7 441 148 41.2 0.74 20 3.96 19.2 428 143 105ºF 39.7 1.00 20 4.05 20.0 437 134 38.5 1.00 22 4.02 19.9 433 133 35.6 1.00 23 3.92 19.4 420 129 59 39.0 1.00 20 4.02 19.9 433 133 37.9 1.00 22 3.99 19.7 429 132 35.0 0.98 22 3.88 19.2 416 128 40.5 1.00 21 4.15 20.4 471 143 39.3 1.00 23 4.11 20.3 466 141 36.3 0.99 24 4.01 19.8 452 137 63 39.9 1.00 20 4.11 20.3 466 141 38.7 0.95 21 4.08 20.1 461 140 35.7 0.92 22 3.97 19.6 448 136 42.4 0.97 21 4.29 21.0 497 156 41.2 0.93 22 4.25 20.9 492 154 38.0 0.89 22 4.14 20.4 477 150 67 42.6 0.81 18 4.25 20.9 492 154 41.4 0.77 18 4.21 20.7 487 153 38.2 0.75 19 4.11 20.2 473 148 45.2 0.79 18 4.44 21.8 518 166 43.9 0.75 19 4.40 21.6 513 164 40.5 0.72 19 4.28 21.0 498 159 71 45.5 0.61 14 4.40 21.6 513 164 44.2 0.58 15 4.36 21.4 508 163 40.8 0.56 15 4.25 20.9 493 158 kW = Total system power Amps = outdoor unit amps (comp.+fan) 48.8 0.78 19 4.28 20.7 469 161 47.4 0.75 20 4.24 20.5 465 159 43.7 0.72 21 4.13 20.0 451 154 71 49.2 0.60 15 4.24 20.5 465 159 47.7 0.57 16 4.21 20.3 460 157 44.1 0.55 16 4.10 19.8 446 153 115ºF Product Specifications Expanded Cooling Data — DSXC160481B* / CA*F4860*6**+TXV/MBVC2000** High stage (cont.) 15 16 www.goodmanmfg.com 1050 1217 1350 67 44.6 0.42 13 2.57 10.4 244 124 43.9 0.41 13 2.56 10.4 242 124 40.5 0.39 14 2.49 10.1 235 120 44.49 0.56 17 2.59 10.5 246 126 43.8 0.54 18 2.58 10.5 244 125 40.5 0.52 18 2.51 10.2 237 121 MBh 39.92 41.10 S/T 0.83 0.75 ∆T 23 21 kW 2.45 2.51 Amps 10.0 10.2 HI PR 217 233 LO PR 108 115 MBh 39.3 40.5 S/T 0.80 0.71 ∆T 24 22 kW 2.44 2.49 Amps 9.9 10.1 HI PR 215 231 LO PR 108 114 MBh 36.3 37.4 S/T 0.77 0.69 ∆T 24 23 kW 2.38 2.43 Amps 9.6 9.9 HI PR 209 224 LO PR 104 111 59 39.3 0.73 20 2.43 9.9 214 107 38.7 0.70 21 2.42 9.8 213 106 35.7 0.68 21 2.36 9.5 207 103 63 40.7 0.61 17 2.49 10.1 231 114 40.1 0.59 18 2.47 10.0 229 113 37.0 0.57 18 2.41 9.8 222 110 Airflow MBh S/T ∆T kW 1350 Amps HI PR LO PR MBh S/T ∆T kW 1217 Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR 47.75 0.36 12 2.68 10.9 257 134 47.0 0.35 12 2.67 10.9 255 133 43.4 0.34 13 2.60 10.6 247 129 71 38.99 0.86 23 2.65 10.8 243 114 38.4 0.83 24 2.64 10.7 241 114 35.5 0.80 25 2.57 10.4 234 110 59 38.3 0.76 20 2.63 10.7 241 113 37.8 0.73 21 2.62 10.6 239 112 34.9 0.70 21 2.55 10.3 232 109 40.14 0.77 21 2.72 11.0 262 122 39.6 0.74 22 2.70 11.0 260 121 36.5 0.71 23 2.63 10.7 252 117 63 39.7 0.63 17 2.69 10.9 259 120 39.2 0.61 18 2.68 10.9 257 120 36.1 0.59 19 2.61 10.6 249 116 43.45 0.58 17 2.81 11.4 276 133 42.8 0.56 18 2.79 11.3 274 132 39.5 0.54 19 2.72 11.0 266 128 67 43.5 0.44 13 2.78 11.3 273 132 42.9 0.42 14 2.77 11.2 271 131 39.6 0.41 14 2.69 10.9 263 127 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 46.64 0.38 12 2.90 11.8 288 142 45.9 0.36 13 2.89 11.7 286 141 42.4 0.35 13 2.81 11.4 277 136 71 38.06 0.89 23 2.83 11.7 276 119 37.5 0.85 24 2.81 11.6 274 118 34.6 0.82 25 2.74 11.3 266 115 59 37.4 0.78 20 2.81 11.6 274 118 36.9 0.75 21 2.79 11.5 272 117 34.0 0.72 21 2.72 11.2 264 113 39.19 0.79 21 2.90 12.0 297 126 38.6 0.76 22 2.88 11.9 295 126 35.6 0.73 23 2.80 11.6 286 122 42.42 0.60 17 3.00 12.4 314 138 41.8 0.57 18 2.98 12.3 312 137 38.6 0.55 19 2.90 12.0 303 133 37.13 0.91 23 2.99 12.5 315 125 36.6 0.88 24 2.97 12.4 313 124 33.8 0.84 25 2.89 12.1 303 120 38.23 0.82 21 3.06 12.8 339 133 37.7 0.78 22 3.04 12.7 336 132 34.8 0.76 23 2.96 12.4 326 128 41.38 0.62 17 3.16 13.2 358 145 40.8 0.59 18 3.14 13.1 355 144 37.6 0.57 19 3.06 12.8 345 140 44.41 0.40 12 3.27 13.7 373 154 43.8 0.38 13 3.25 13.6 370 153 40.4 0.37 13 3.17 13.3 359 149 71 35.28 0.95 23 3.12 13.3 354 131 34.8 0.91 24 3.10 13.2 352 130 32.1 0.88 25 3.02 12.9 341 126 59 34.7 0.83 20 3.09 13.2 351 130 34.2 0.80 21 3.07 13.1 348 129 31.5 0.77 21 2.99 12.7 338 125 Shaded area reflects ACCA (TVA) conditions 45.52 0.39 12 3.10 12.8 328 147 44.9 0.37 13 3.08 12.8 325 146 41.4 0.36 13 3.00 12.4 316 142 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 38.8 42.5 36.5 37.8 41.5 0.65 0.45 0.80 0.67 0.47 17 13 20 17 13 2.87 2.97 2.96 3.03 3.14 11.9 12.3 12.4 12.7 13.1 294 311 312 335 354 125 137 124 132 144 38.2 41.9 36.0 37.3 40.9 0.62 0.43 0.77 0.64 0.45 18 14 21 18 14 2.85 2.95 2.94 3.01 3.12 11.8 12.2 12.3 12.6 13.0 292 309 309 333 352 124 136 123 131 143 35.3 38.6 33.2 34.4 37.7 0.60 0.42 0.74 0.62 0.43 19 14 22 19 14 2.78 2.88 2.87 2.93 3.03 11.5 11.8 12.0 12.3 12.7 284 299 300 323 341 121 132 119 127 138 36.32 0.85 21 3.19 13.6 381 139 35.8 0.81 22 3.17 13.5 378 138 33.0 0.78 23 3.09 13.2 367 134 63 36.0 0.70 17 3.17 13.5 377 138 35.4 0.67 18 3.15 13.4 375 137 32.7 0.64 18 3.06 13.0 363 133 39.31 0.64 17 3.31 14.1 402 152 38.7 0.62 18 3.28 14.0 400 151 35.8 0.59 19 3.20 13.6 388 146 67 39.4 0.48 13 3.28 14.0 398 150 38.8 0.46 14 3.26 13.9 396 149 35.8 0.45 14 3.17 13.5 384 145 105ºF 32.68 0.96 21 3.24 14.1 391 135 32.2 0.92 22 3.22 14.0 389 134 29.7 0.88 23 3.13 13.6 377 130 59 32.1 0.84 18 3.21 14.0 387 134 31.7 0.81 19 3.19 13.9 385 133 29.2 0.78 20 3.10 13.5 373 129 33.64 0.86 20 3.31 14.4 421 144 33.1 0.82 21 3.29 14.4 418 143 30.6 0.79 21 3.20 14.0 406 139 63 33.3 0.70 16 3.28 14.3 417 143 32.8 0.67 17 3.26 14.2 414 142 30.3 0.65 17 3.18 13.8 401 137 36.42 0.65 16 3.43 14.9 445 157 35.9 0.62 17 3.41 14.8 442 156 33.1 0.60 17 3.32 14.4 428 151 67 36.5 0.49 12 3.40 14.8 440 156 35.9 0.47 13 3.38 14.7 437 155 33.2 0.45 13 3.29 14.3 424 150 39.08 0.42 11 3.55 15.5 464 167 38.5 0.40 12 3.53 15.4 461 166 35.5 0.38 12 3.43 15.0 447 161 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 42.19 0.41 12 3.42 14.6 420 162 41.6 0.40 12 3.40 14.5 417 161 38.4 0.38 13 3.31 14.1 404 156 71 - 115ºF Product Specifications Expanded Cooling Data — DSXC160601B* / CA*F4961*6A*+TXV / MBVC2000**-1** Low Stage SS-DSXC16 SS-DSXC16 www.goodmanmfg.com 44.13 0.83 25 2.64 10.7 251 128 43.5 0.80 26 2.62 10.7 249 127 40.1 0.77 27 2.56 10.4 242 124 MBh 41.34 42.14 S/T 0.96 0.92 ∆T 27 27 kW 2.50 2.55 Amps 10.1 10.4 HI PR 221 238 LO PR 110 118 MBh 40.7 41.5 S/T 0.92 0.89 ∆T 28 28 kW 2.48 2.54 Amps 10.1 10.3 HI PR 219 236 LO PR 110 117 MBh 37.6 38.3 S/T 0.88 0.85 ∆T 29 29 kW 2.42 2.47 Amps 9.8 10.0 HI PR 213 229 LO PR 106 113 1050 1217 1350 67 44.35 0.70 21 2.62 10.6 249 127 43.7 0.67 22 2.60 10.6 247 126 40.3 0.64 23 2.53 10.3 239 122 Airflow 59 63 MBh 40.63 41.51 S/T 0.91 0.86 ∆T 25 24 kW 2.47 2.53 1350 Amps 10.1 10.3 HI PR 219 235 LO PR 109 116 MBh 40.0 40.9 S/T 0.88 0.82 ∆T 26 25 kW 2.46 2.52 1217 Amps 10.0 10.2 HI PR 217 234 LO PR 109 116 MBh 36.9 37.8 S/T 0.84 0.79 ∆T 27 26 1050 kW 2.40 2.45 Amps 9.7 10.0 HI PR 211 227 LO PR 105 112 47.08 0.68 22 2.73 11.1 262 137 46.4 0.65 23 2.71 11.1 260 136 42.8 0.63 23 2.64 10.8 252 132 40.38 0.99 27 2.70 11.0 248 117 39.8 0.95 29 2.68 10.9 246 116 36.7 0.92 29 2.62 10.6 239 112 41.16 0.96 27 2.76 11.2 267 124 40.5 0.92 28 2.75 11.2 265 123 37.4 0.88 29 2.67 10.9 257 120 71 59 63 47.41 39.68 40.55 0.52 0.95 0.89 17 26 25 2.70 2.68 2.74 11.0 10.9 11.1 259 245 264 135 116 123 46.7 39.1 39.9 0.50 0.91 0.85 18 27 26 2.69 2.66 2.72 11.0 10.8 11.1 257 244 262 134 115 122 43.1 36.1 36.9 0.48 0.87 0.82 18 28 26 2.62 2.59 2.65 10.7 10.5 10.8 250 236 254 130 111 118 43.11 0.86 25 2.86 11.6 282 136 42.5 0.83 27 2.84 11.5 280 135 39.2 0.80 27 2.77 11.2 271 131 67 43.32 0.72 21 2.83 11.5 279 134 42.7 0.69 22 2.81 11.4 277 133 39.4 0.67 23 2.74 11.1 269 129 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 45.99 0.70 22 2.96 12.0 294 144 45.3 0.67 23 2.94 12.0 292 143 41.8 0.65 24 2.86 11.6 283 139 39.41 1.00 27 2.88 11.9 282 121 38.8 0.98 29 2.86 11.8 280 120 35.8 0.94 30 2.79 11.5 272 117 71 59 46.31 38.74 0.54 0.97 17 26 2.93 2.86 11.9 11.8 291 279 143 120 45.6 38.2 0.52 0.93 18 27 2.91 2.84 11.8 11.7 289 277 142 119 42.1 35.2 0.50 0.90 18 28 2.84 2.77 11.5 11.4 280 269 138 116 40.18 0.98 27 2.95 12.2 303 129 39.6 0.94 28 2.93 12.1 301 128 36.5 0.91 29 2.85 11.8 292 124 42.08 0.89 25 3.05 12.6 320 141 41.5 0.85 27 3.03 12.5 318 140 38.3 0.82 27 2.95 12.2 309 136 44.89 0.72 22 3.16 13.1 334 150 44.2 0.69 23 3.14 13.0 332 149 40.8 0.66 24 3.05 12.6 322 145 39.20 1.00 27 3.11 13.0 346 136 38.6 0.97 28 3.09 13.0 343 135 35.6 0.94 29 3.01 12.6 333 131 41.05 0.92 26 3.22 13.5 365 148 40.4 0.88 27 3.20 13.4 362 147 37.3 0.85 28 3.12 13.0 352 143 43.80 0.74 22 3.33 14.0 381 158 43.1 0.71 23 3.31 13.9 378 157 39.8 0.69 24 3.22 13.5 367 152 71 44.11 0.57 17 3.30 13.9 377 156 43.5 0.55 18 3.28 13.8 374 155 40.1 0.53 19 3.20 13.4 363 150 36.53 1.00 25 3.18 13.6 361 134 36.0 1.00 27 3.16 13.5 359 133 33.2 1.00 29 3.07 13.1 348 129 59 35.90 1.00 24 3.15 13.4 358 132 35.4 1.00 27 3.13 13.3 355 131 32.6 0.96 27 3.05 13.0 345 127 Shaded area reflects AHRI (TVA) conditions 38.45 1.00 26 3.04 12.7 321 127 37.9 1.00 29 3.02 12.7 319 127 35.0 0.97 30 2.94 12.3 309 123 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 39.58 42.29 45.21 37.79 38.62 41.26 0.91 0.74 0.55 1.00 0.94 0.77 25 21 17 26 25 22 2.92 3.02 3.13 3.01 3.08 3.19 12.1 12.5 13.0 12.6 12.9 13.4 300 317 331 318 342 361 128 139 149 126 134 147 39.0 41.7 44.5 37.2 38.0 40.6 0.87 0.71 0.53 0.96 0.90 0.73 26 22 18 27 26 23 2.90 3.00 3.11 3.00 3.07 3.17 12.0 12.4 12.9 12.5 12.8 13.3 298 315 329 316 340 359 127 139 148 125 133 146 36.0 38.5 41.1 34.4 35.1 37.5 0.84 0.68 0.51 0.93 0.87 0.71 27 23 18 28 27 23 2.83 2.93 3.03 2.92 2.99 3.09 11.7 12.1 12.5 12.2 12.5 12.9 289 306 319 306 330 348 123 134 143 122 129 141 37.24 1.00 25 3.25 13.9 389 142 36.7 1.00 28 3.23 13.8 386 141 33.9 0.97 29 3.15 13.4 374 137 63 36.69 0.98 24 3.22 13.8 385 141 36.1 0.93 26 3.20 13.7 382 140 33.4 0.90 26 3.12 13.3 371 135 39.00 0.95 25 3.36 14.4 411 155 38.4 0.91 26 3.34 14.3 408 154 35.5 0.88 27 3.25 13.9 395 149 67 39.20 0.79 21 3.33 14.2 406 154 38.6 0.76 22 3.31 14.1 404 152 35.6 0.73 23 3.23 13.7 392 148 105ºF 33.84 1.00 23 3.29 14.4 399 138 33.3 1.00 25 3.27 14.3 396 137 30.8 1.00 27 3.19 13.9 385 133 59 33.26 1.00 23 3.26 14.2 395 137 32.8 1.00 25 3.24 14.1 392 136 30.2 0.97 26 3.16 13.7 381 132 34.49 1.00 23 3.37 14.7 430 147 34.0 1.00 26 3.35 14.6 427 146 31.4 0.98 27 3.26 14.2 414 142 63 33.98 0.98 23 3.34 14.6 425 145 33.5 0.94 24 3.32 14.5 422 144 30.9 0.91 25 3.23 14.1 410 140 36.13 0.96 24 3.49 15.2 454 160 35.6 0.92 25 3.47 15.1 450 159 32.9 0.88 25 3.38 14.7 437 155 67 36.31 0.80 20 3.46 15.1 449 159 35.8 0.77 21 3.44 15.0 446 158 33.0 0.74 21 3.35 14.6 433 153 38.54 0.78 20 3.61 15.8 473 171 38.0 0.74 21 3.59 15.7 470 170 35.0 0.72 22 3.49 15.3 456 165 71 38.81 0.60 16 3.58 15.6 468 169 38.2 0.57 17 3.56 15.5 465 168 35.3 0.55 17 3.46 15.1 451 163 kW = Total system power Amps = outdoor unit amps (comp.+fan) 41.61 0.77 22 3.48 14.9 428 165 41.0 0.74 23 3.46 14.8 425 164 37.8 0.71 24 3.37 14.4 412 159 71 41.90 0.59 17 3.45 14.8 424 164 41.3 0.57 18 3.43 14.7 421 162 38.1 0.55 18 3.34 14.3 408 158 115ºF Product Specifications Expanded Cooling Data — DSXC160601B*/CA*F4961*6A*+TXV / MBVC2000**-1** Low Stage (cont.) 17 18 www.goodmanmfg.com 1575 1800 2025 67 63.4 0.43 12 3.77 14.9 262 121 61.6 0.41 13 3.74 14.8 260 120 56.8 0.40 13 3.65 14.4 252 116 63.30 0.57 16 3.81 15.0 265 122 61.5 0.55 17 3.78 14.9 262 121 56.7 0.53 17 3.68 14.5 254 117 MBh 56.80 58.48 S/T 0.84 0.76 ∆T 22 20 kW 3.60 3.68 Amps 14.2 14.6 HI PR 233 251 LO PR 105 112 MBh 55.1 56.8 S/T 0.81 0.72 ∆T 23 21 kW 3.57 3.65 Amps 14.1 14.4 HI PR 231 248 LO PR 104 111 MBh 50.9 52.4 S/T 0.78 0.69 ∆T 23 21 kW 3.48 3.56 Amps 13.7 14.0 HI PR 224 241 LO PR 101 108 59 55.9 0.74 19 3.57 14.1 231 104 54.2 0.71 20 3.54 13.9 229 103 50.1 0.68 20 3.45 13.6 222 100 63 57.9 0.62 16 3.65 14.4 248 111 56.2 0.59 17 3.62 14.3 246 110 51.9 0.57 17 3.53 13.9 239 106 Airflow MBh S/T ∆T kW 2025 Amps HI PR LO PR MBh S/T ∆T kW 1800 Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR 67.94 0.37 11 3.94 15.6 276 130 66.0 0.35 12 3.90 15.5 274 129 60.9 0.34 12 3.80 15.0 265 125 71 55.48 0.88 22 3.90 15.4 262 111 53.9 0.84 23 3.87 15.3 259 110 49.7 0.81 23 3.77 14.8 251 107 59 54.6 0.77 19 3.86 15.2 259 110 53.0 0.73 20 3.83 15.1 256 109 48.9 0.71 20 3.73 14.7 249 106 57.12 0.78 20 3.99 15.8 282 118 55.5 0.75 21 3.95 15.6 279 117 51.2 0.72 22 3.85 15.2 270 114 63 56.5 0.64 17 3.95 15.6 279 117 54.9 0.61 17 3.92 15.5 276 116 50.7 0.59 17 3.82 15.0 268 112 61.83 0.59 17 4.12 16.3 297 129 60.0 0.57 17 4.09 16.2 294 128 55.4 0.55 18 3.98 15.7 286 124 67 62.0 0.45 13 4.09 16.2 294 128 60.1 0.43 13 4.05 16.0 291 127 55.5 0.41 13 3.95 15.6 283 123 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 66.36 0.38 11 4.27 16.9 310 138 64.4 0.36 12 4.23 16.8 307 136 59.5 0.35 12 4.12 16.3 298 132 71 54.16 0.90 22 4.16 16.8 298 116 52.6 0.86 23 4.12 16.6 295 114 48.5 0.83 23 4.02 16.1 286 111 59 53.3 0.79 19 4.12 16.6 295 114 51.7 0.75 20 4.09 16.5 292 113 47.7 0.73 20 3.98 16.0 283 110 55.76 0.80 20 4.26 17.2 320 123 54.1 0.77 21 4.22 17.0 317 122 50.0 0.74 22 4.11 16.5 308 118 60.36 0.61 17 4.40 17.8 338 134 58.6 0.58 17 4.36 17.6 335 133 54.1 0.56 18 4.25 17.1 325 129 52.84 0.93 22 4.39 18.0 339 121 51.3 0.88 23 4.35 17.8 336 120 47.3 0.85 24 4.24 17.3 326 117 54.40 0.83 20 4.49 18.4 365 129 52.8 0.79 21 4.45 18.2 361 128 48.8 0.76 22 4.34 17.7 350 124 58.89 0.63 17 4.65 19.0 385 141 57.2 0.60 17 4.61 18.9 381 140 52.8 0.58 18 4.49 18.3 370 135 63.20 0.40 12 4.81 19.8 402 150 61.4 0.38 12 4.77 19.6 398 149 56.6 0.37 12 4.64 19.0 386 144 71 50.20 0.96 22 4.59 19.1 381 127 48.7 0.92 23 4.55 19.0 378 126 45.0 0.88 23 4.43 18.4 366 122 59 49.4 0.85 19 4.55 19.0 377 126 47.9 0.81 20 4.51 18.8 374 125 44.2 0.78 20 4.39 18.2 363 121 Shaded area reflects ACCA (TVA) conditions 64.78 0.39 12 4.56 18.5 353 143 62.9 0.37 12 4.52 18.3 349 142 58.1 0.36 12 4.40 17.8 339 137 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 55.2 60.5 52.0 53.9 59.0 0.66 0.46 0.82 0.68 0.47 17 13 19 17 13 4.22 4.36 4.35 4.45 4.61 17.0 17.6 17.8 18.2 18.9 317 335 336 361 381 122 133 120 128 140 53.6 58.7 50.4 52.3 57.3 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 4.18 4.33 4.31 4.41 4.57 16.9 17.4 17.6 18.1 18.7 314 331 332 357 377 120 132 119 127 138 49.5 54.2 46.6 48.3 52.9 0.61 0.42 0.75 0.63 0.43 18 13 20 18 13 4.07 4.21 4.20 4.30 4.45 16.4 16.9 17.1 17.5 18.1 304 321 322 347 366 117 128 115 123 134 51.68 0.86 20 4.70 19.6 410 135 50.2 0.82 21 4.65 19.4 406 134 46.3 0.79 21 4.53 18.9 394 130 63 51.2 0.71 16 4.65 19.4 406 134 49.7 0.67 17 4.61 19.2 402 133 45.8 0.65 17 4.49 18.7 390 129 55.94 0.65 17 4.86 20.3 433 148 54.3 0.62 17 4.82 20.1 429 146 50.1 0.60 18 4.69 19.5 416 142 67 56.1 0.49 12 4.82 20.1 429 146 54.4 0.47 13 4.77 19.9 425 145 50.2 0.45 13 4.65 19.3 412 140 105ºF 46.50 0.97 20 4.76 20.3 421 132 45.1 0.93 21 4.71 20.1 417 130 41.7 0.89 22 4.59 19.5 405 126 59 45.7 0.85 18 4.71 20.1 417 130 44.4 0.81 18 4.67 19.9 413 129 41.0 0.78 19 4.55 19.4 401 125 47.87 0.87 19 4.87 20.8 453 140 46.5 0.83 20 4.83 20.6 449 139 42.9 0.80 20 4.70 20.0 435 134 63 47.4 0.71 15 4.83 20.6 449 139 46.0 0.68 16 4.78 20.4 444 137 42.5 0.66 16 4.66 19.8 431 133 51.82 0.66 15 5.04 21.5 479 153 50.3 0.63 16 5.00 21.3 474 151 46.4 0.60 16 4.86 20.7 460 147 67 51.9 0.49 12 4.99 21.3 474 151 50.4 0.47 12 4.95 21.1 469 150 46.5 0.45 12 4.82 20.5 455 145 55.62 0.42 11 5.22 22.4 499 163 54.0 0.40 11 5.17 22.2 494 161 49.8 0.39 11 5.03 21.5 480 156 71 - kW = Total system power Amps = outdoor unit amps (comp.+fan) 60.04 0.42 11 5.03 21.1 452 157 58.3 0.40 12 4.99 20.9 447 156 53.8 0.39 12 4.85 20.3 434 151 71 - 115ºF Product Specifications Expanded Cooling Data — DSXC160601B* / CA*F4961*6A*+TXV / MBVC2000**-1** High Stage SS-DSXC16 SS-DSXC16 www.goodmanmfg.com 62.80 0.85 24 3.87 15.3 270 125 61.0 0.81 25 3.84 15.2 268 123 56.3 0.78 26 3.74 14.8 260 120 MBh 58.82 59.96 S/T 0.97 0.94 ∆T 26 26 kW 3.66 3.75 Amps 14.5 14.8 HI PR 238 256 LO PR 107 114 MBh 57.1 58.2 S/T 0.93 0.89 ∆T 27 27 kW 3.63 3.72 Amps 14.3 14.7 HI PR 236 253 LO PR 106 113 MBh 52.7 53.7 S/T 0.89 0.86 ∆T 27 27 kW 3.54 3.62 Amps 13.9 14.3 HI PR 228 246 LO PR 103 110 1575 1800 2025 67 63.11 0.71 20 3.84 15.2 268 123 61.3 0.67 21 3.81 15.1 265 122 56.6 0.65 21 3.71 14.6 257 119 Airflow 59 63 MBh 57.81 59.07 S/T 0.93 0.87 ∆T 24 23 kW 3.63 3.72 2025 Amps 14.3 14.7 HI PR 236 253 LO PR 106 113 MBh 56.1 57.4 S/T 0.88 0.83 ∆T 25 24 kW 3.60 3.68 1800 Amps 14.2 14.6 HI PR 233 251 LO PR 105 112 MBh 51.8 52.9 S/T 0.85 0.80 ∆T 26 25 1575 kW 3.51 3.59 Amps 13.8 14.2 HI PR 226 243 LO PR 102 109 67.00 0.69 21 4.01 15.9 282 133 65.0 0.65 22 3.97 15.8 279 131 60.0 0.63 22 3.87 15.3 271 128 57.45 1.00 26 3.97 15.7 267 113 55.8 0.96 27 3.93 15.5 264 112 51.5 0.93 28 3.83 15.1 256 109 58.57 0.97 26 4.06 16.1 287 121 56.9 0.93 27 4.02 15.9 284 119 52.5 0.89 27 3.92 15.5 276 116 71 59 63 67.47 56.47 57.70 0.53 0.96 0.90 16 25 24 3.97 3.93 4.02 15.8 15.5 15.9 279 264 284 131 112 119 65.5 54.8 56.0 0.50 0.92 0.86 17 26 25 3.94 3.90 3.99 15.6 15.4 15.8 276 262 282 130 111 118 60.5 50.6 51.7 0.49 0.88 0.83 17 26 25 3.84 3.80 3.88 15.2 15.0 15.3 268 254 273 126 108 115 61.34 0.88 24 4.20 16.6 303 132 59.6 0.84 25 4.16 16.5 300 130 55.0 0.81 26 4.05 16.0 291 127 67 61.65 0.73 21 4.16 16.5 300 130 59.9 0.70 21 4.12 16.3 297 129 55.2 0.67 22 4.02 15.9 288 125 75ºF IDB = Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 65.44 0.71 21 4.34 17.3 316 140 63.5 0.68 22 4.30 17.1 313 139 58.6 0.65 22 4.19 16.6 304 135 56.09 1.00 25 4.23 17.1 304 118 54.5 0.98 27 4.20 16.9 301 117 50.3 0.95 28 4.09 16.4 292 113 71 59 65.90 55.12 0.55 1.00 16 25 4.30 4.20 17.1 16.9 313 301 139 117 64.0 53.5 0.52 0.94 17 26 4.27 4.16 16.9 16.8 310 298 138 116 59.1 49.4 0.50 0.91 17 26 4.16 4.05 16.5 16.3 301 289 133 112 57.17 1.00 26 4.33 17.5 327 125 55.5 0.95 27 4.29 17.3 323 124 51.2 0.92 27 4.18 16.9 314 120 59.88 0.90 24 4.48 18.1 345 137 58.1 0.86 25 4.44 17.9 342 136 53.7 0.83 26 4.33 17.4 331 132 63.88 0.73 21 4.64 18.8 360 146 62.0 0.70 22 4.60 18.6 356 144 57.2 0.67 22 4.48 18.1 346 140 55.78 1.00 25 4.57 18.8 372 132 54.2 0.98 27 4.53 18.6 368 130 50.0 0.95 28 4.41 18.1 357 127 58.42 0.93 25 4.73 19.4 393 144 56.7 0.89 26 4.69 19.2 389 142 52.3 0.85 26 4.57 18.7 377 138 62.32 0.75 21 4.90 20.2 410 153 60.5 0.72 22 4.86 20.0 406 152 55.8 0.69 23 4.73 19.4 394 147 71 62.76 0.58 17 4.86 20.0 406 152 60.9 0.55 17 4.81 19.8 402 150 56.2 0.53 18 4.69 19.2 390 146 51.98 1.00 24 4.67 19.5 389 130 50.5 1.00 26 4.63 19.3 385 129 46.6 1.00 27 4.51 18.8 374 125 59 51.09 1.00 23 4.63 19.3 385 129 49.6 1.00 25 4.59 19.1 381 127 45.8 0.97 26 4.47 18.6 370 123 Shaded area reflects AHRI (TVA) conditions 54.72 1.00 25 4.47 18.3 346 124 53.1 1.00 27 4.43 18.1 342 123 49.0 0.98 28 4.31 17.6 332 119 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 56.33 60.18 64.33 53.78 54.95 58.71 0.92 0.75 0.56 1.00 0.95 0.78 24 21 16 24 24 21 4.29 4.44 4.60 4.43 4.53 4.69 17.3 17.9 18.6 18.1 18.6 19.2 323 342 356 342 368 389 124 136 144 123 130 142 54.7 58.4 62.5 52.2 53.4 57.0 0.88 0.72 0.54 0.97 0.91 0.74 25 21 17 26 25 22 4.26 4.40 4.56 4.39 4.49 4.65 17.2 17.8 18.5 18.0 18.4 19.0 320 338 353 339 365 385 123 134 143 121 129 141 50.5 53.9 57.6 48.2 49.2 52.6 0.85 0.69 0.52 0.93 0.88 0.71 25 22 17 26 25 22 4.15 4.29 4.44 4.28 4.38 4.53 16.7 17.3 17.9 17.4 17.9 18.5 311 328 342 329 354 374 119 130 139 118 125 137 52.99 1.00 24 4.78 20.0 419 138 51.4 1.00 26 4.74 19.8 414 137 47.5 0.98 27 4.61 19.2 402 133 63 52.20 1.00 24 4.74 19.8 414 137 50.7 0.94 24 4.70 19.6 410 135 46.8 0.91 25 4.57 19.1 398 131 55.50 0.96 24 4.95 20.7 442 151 53.9 0.92 25 4.90 20.5 438 149 49.7 0.89 26 4.77 19.9 425 145 67 55.77 0.81 20 4.90 20.5 438 149 54.2 0.77 21 4.86 20.3 433 148 50.0 0.74 22 4.73 19.7 420 143 105ºF 48.15 1.00 22 4.84 20.7 430 134 46.7 1.00 24 4.80 20.5 426 133 43.1 1.00 25 4.67 19.9 413 129 59 47.32 1.00 21 4.80 20.5 426 133 45.9 1.00 23 4.76 20.3 421 132 42.4 0.98 24 4.63 19.7 409 128 49.08 1.00 22 4.96 21.2 463 143 47.7 1.00 24 4.91 21.0 458 141 44.0 0.99 25 4.78 20.4 444 137 63 48.36 1.00 22 4.91 21.0 458 141 46.9 0.95 23 4.87 20.8 453 140 43.3 0.92 23 4.74 20.2 440 136 51.41 0.97 23 5.13 22.0 488 156 49.9 0.93 24 5.09 21.7 484 154 46.1 0.89 24 4.95 21.1 469 150 67 51.66 0.81 19 5.09 21.7 484 154 50.2 0.77 20 5.04 21.5 479 153 46.3 0.75 20 4.91 20.9 464 148 54.84 0.79 20 5.31 22.8 509 166 53.2 0.75 20 5.27 22.6 504 164 49.1 0.72 21 5.13 21.9 489 159 71 55.23 0.61 15 5.27 22.6 504 164 53.6 0.58 16 5.22 22.4 499 163 49.5 0.56 16 5.08 21.7 484 158 kW = Total system power Amps = outdoor unit amps (comp.+fan) 59.21 0.78 21 5.12 21.5 461 161 57.5 0.75 22 5.08 21.3 457 159 53.1 0.72 22 4.94 20.7 443 154 71 59.62 0.60 16 5.08 21.3 457 159 57.9 0.57 17 5.03 21.1 452 157 53.4 0.55 17 4.90 20.5 438 153 115ºF Product Specifications Expanded Cooling Data — DSXC160601B*/CA*F4961*6A*+TXV / MBVC2000**-1** High Stage (cont.) 19 Product Specifications AHRI Ratings Indoor Units Outdoor Unit Coils/Air Handlers Cooling Ratings Furnaces AHRI # 12.50 830 5924460 14.50 12.00 820 5357193 16.00 13.00 820 4392752 5038827 Sens.¹ SEER² EER³ AVPTC30C14A* 23,000 16,800 16.00 CA*F3636*6D*+EEP+TXV 24,000 17,600 CA*F3636*6D*+MBVC1200**-1A*+TXV 24,000 17,600 CA*F3636*6D*+TXV G*VC80604B*B* 24,000 17,600 16.00 13.00 820 CA*F3636*6D*+TXV A*VC80604B*B* 24,000 17,600 16.00 13.00 820 5039091 CA*F3636*6D*+TXV G*VC950453BXB* 24,000 17,600 16.00 13.00 820 5620613 CA*F3636*6D*+TXV G*VC950704CXB* 24,000 17,600 16.00 13.00 800 5620620 CA*F3636*6D*+TXV A*VC950714CXB* 24,000 17,600 16.00 13.00 800 5620626 CA*F3636*6D*+TXV G*VC950714CXB* 24,000 17,600 16.00 13.00 800 5620627 CA*F3636*6D*+TXV G*VM960603BXB* 24,000 17,600 16.00 13.00 820 5620630 CA*F3636*6D*+TXV A*VM960604CXB* 24,000 17,600 16.00 13.00 800 5620635 CA*F3636*6D*+TXV G*VM960604CXB* 24,000 17,600 16.00 13.00 800 5620636 CA*F3636*6D*+TXV A*VC950453BXB* 24,000 17,600 16.00 13.00 820 6497619 CA*F3636*6D*+TXV A*VC950704CXB* 24,000 17,600 16.00 13.00 800 6497620 CA*F3636*6D*+TXV A*VM960603BXB* 24,000 17,600 16.00 13.00 820 6497621 CA*F3636*6D*+TXV ADVC80603B*B* 24,000 17,600 16.00 13.00 810 6497622 24,000 17,600 14.50 12.00 820 5357194 CA*F3642*6D*+TXV A*VC80604B*B* 24,000 17,600 16.00 13.00 820 5039010 CA*F3642*6D*+TXV G*VC80604B*B* 24,000 17,600 16.00 13.00 820 5039220 CA*F3642*6D*+TXV G*VC950453BXB* 24,000 17,600 16.00 13.00 820 5620614 CA*F3642*6D*+TXV G*VC950704CXB* 24,000 17,600 16.00 13.00 800 5620621 CA*F3642*6D*+TXV A*VC950714CXB* 24,000 17,600 16.00 13.00 800 5620628 CA*F3642*6D*+TXV G*VC950714CXB* 24,000 17,600 16.00 13.00 800 5620629 CA*F3642*6D*+TXV G*VM960603BXB* 24,000 17,600 16.00 13.00 820 5620631 CA*F3642*6D*+TXV A*VM960604CXB* 24,000 17,600 16.00 13.00 800 5620637 CA*F3642*6D*+TXV G*VM960604CXB* 24,000 17,600 16.00 13.00 800 5620638 CA*F3642*6D*+TXV A*VC950704CXB* 24,000 17,600 16.00 13.00 800 6497623 CA*F3642*6D*+TXV A*VC950905CXB* 24,000 17,600 16.00 13.00 800 6497624 CA*F3642*6D*+TXV A*VC950915DXB* 24,000 17,600 16.00 13.00 800 6497625 CA*F3642*6D*+TXV A*VM960805CXB* 24,000 17,600 16.00 13.00 800 6497626 CA*F3642*6D*+TXV A*VM960805DXB* 24,000 17,600 16.00 13.00 800 6497627 CA*F3642*6D*+TXV G*VC950905CXB* 24,000 17,600 16.00 13.00 800 6497628 CA*F3642*6D*+TXV G*VC950915DXB* 24,000 17,600 16.00 13.00 800 6497629 CA*F3642*6D*+TXV G*VM960805CXB* 24,000 17,600 16.00 13.00 800 6497630 CA*F3642*6D*+TXV G*VM960805DXB* 24,000 17,600 16.00 13.00 800 6497631 24,000 17,600 14.50 12.00 820 5357195 CA*F3642*6D*+EEP+TXV DSXC16 0241A* CFM Total¹ CHPF3636B6C*+EEP+TXV CHPF3636B6C*+MBVC1200**-1A*+TXV 24,000 17,600 16.00 13.00 820 3653937 CHPF3636B6C*+TXV G*VC80604B*B* 24,000 17,600 16.00 13.00 820 5039090 CHPF3636B6C*+TXV A*VC80604B*B* 24,000 17,600 16.00 13.00 820 5039103 CHPF3636B6C*+TXV G*VC950453BXB* 24,000 17,600 16.00 13.00 820 5620615 CHPF3636B6C*+TXV G*VM960603BXB* 24,000 17,600 16.00 13.00 820 5620632 CHPF3636B6C*+TXV A*VM960604CXB* 24,000 17,600 16.00 12.50 800 5620639 CHPF3636B6C*+TXV G*VM960604CXB* 24,000 17,600 16.00 12.50 800 5620640 CHPF3636B6C*+TXV A*VC950453BXB* 24,000 17,600 16.00 13.00 820 6497632 CHPF3636B6C*+TXV A*VC950704CXB* 24,000 17,600 16.00 12.50 800 6497633 See Notes on Page 29. 20 www.goodmanmfg.com SS-DSXC16 Product Specifications AHRI Ratings (cont.) Indoor Units Outdoor Unit DSXC16 0241A* (cont.) Coils/Air Handlers Cooling Ratings Furnaces Sens.¹ SEER² EER³ 24,000 17,600 16.00 13.00 CFM AHRI # 820 6497634 CHPF3636B6C*+TXV A*VM960603BXB* CHPF3636B6C*+TXV G*VC950704CXB* 24,000 17,600 16.00 12.50 800 6497635 CHPF3642C6C*+TXV G*VC950453BXB* 24,000 17,600 16.00 13.00 820 5620616 CHPF3642C6C*+TXV G*VC950704CXB* 24,000 17,600 16.00 13.00 800 5620622 CHPF3642C6C*+TXV G*VM960603BXB* 24,000 17,600 16.00 13.00 820 5620633 CHPF3642C6C*+TXV A*VM960604CXB* 24,000 17,600 16.00 13.00 800 5620641 CHPF3642C6C*+TXV G*VM960604CXB* 24,000 17,600 16.00 13.00 800 5620642 CHPF3642C6C*+TXV A*VC950453BXB* 24,000 17,600 16.00 13.00 820 6497636 CHPF3642C6C*+TXV A*VC950704CXB* 24,000 17,600 16.00 13.00 800 6497637 CHPF3642C6C*+TXV A*VM960603BXB* 24,000 17,600 16.00 13.00 820 6497638 CHPF3743C6B*+TXV G*VC950453BXB* 24,000 17,600 16.00 12.50 820 5620617 CHPF3743C6B*+TXV G*VC950704CXB* 24,000 17,600 16.00 12.50 800 5620623 CHPF3743C6B*+TXV G*VM960603BXB* 24,000 17,600 16.00 12.50 820 5620634 CHPF3743C6B*+TXV A*VM960604CXB* 24,000 17,600 16.00 12.50 800 5620643 CHPF3743C6B*+TXV G*VM960604CXB* 24,000 17,600 16.00 12.50 800 5620644 CHPF3743C6B*+TXV A*VC950453BXB* 24,000 17,600 16.00 12.50 820 6497639 CHPF3743C6B*+TXV A*VC950704CXB* 24,000 17,600 16.00 12.50 800 6497640 CHPF3743C6B*+TXV A*VM960603BXB* 24,000 17,600 16.00 12.50 820 6497641 CSCF3036N6D*+TXV G*VC950453BXB* 24,000 17,600 15.50 12.50 800 5620618 CSCF3036N6D*+TXV G*VC950704CXB* 24,000 17,600 16.00 13.00 875 5620624 CSCF3036N6D*+TXV A*VC80604B*B* 24,000 17,600 16.00 13.00 820 6497642 CSCF3036N6D*+TXV A*VC950453BXB* 24,000 17,600 15.50 12.50 800 6497643 CSCF3036N6D*+TXV A*VC950704CXB* 24,000 17,600 16.00 13.00 875 6497644 CSCF3036N6D*+TXV A*VC950905CXB* 24,000 17,600 16.00 13.00 800 6497645 CSCF3036N6D*+TXV G*VC80604B*B* 24,000 17,600 16.00 13.00 820 6497646 CSCF3036N6D*+TXV G*VC950905CXB* 24,000 17,600 16.00 13.00 800 6497647 24,000 17,600 14.50 12.00 820 5357196 CSCF3642N6D*+TXV G*VC950453BXB* 24,000 17,600 16.00 13.00 800 5620619 CSCF3642N6D*+TXV G*VC950704CXB* 24,000 17,600 16.00 13.00 875 5620625 CSCF3642N6D*+TXV A*VC80604B*B* 24,000 17,600 16.00 13.00 820 5948539 CSCF3642N6D*+TXV G*VC80604B*B* 24,000 17,600 16.00 13.00 820 5948540 CSCF3642N6D*+TXV A*VC950453BXB* 24,000 17,600 16.00 13.00 800 6497648 CSCF3642N6D*+TXV A*VC950704CXB* 24,000 17,600 16.00 13.00 875 6497649 CSCF3642N6D*+TXV A*VC950905CXB* 24,000 17,600 16.00 13.00 800 6497650 CSCF3642N6D*+TXV G*VC950905CXB* CSCF3642N6D*+EEP+TXV 24,000 17,600 16.00 13.00 800 6497651 AVPTC42D14A* 35,000 25,200 16.00 12.00 1,200 5924363 AVPTC48D14A* 36,000 25,800 16.00 12.50 1,200 5924364 CA*F3642*6D*+MBVC1600**-1A*+TXV 35,000 25,200 16.00 12.50 1,200 3880067 34,000 24,400 16.00 12.00 1,220 5038810 CA*F3642*6D*+TXV DSXC16 0361A* Total¹ A*VC80604B*B* CA*F3642*6D*+TXV G*VC80604B*B* 34,000 24,400 16.00 12.00 1,220 5039092 CA*F3642*6D*+TXV G*VC950704CXB* 34,600 24,800 16.00 12.00 1,100 5620651 CA*F3642*6D*+TXV A*VC950714CXB* 34,600 24,800 16.00 12.00 1,100 5620658 CA*F3642*6D*+TXV G*VC950714CXB* 34,600 24,800 16.00 12.00 1,100 5620659 CA*F3642*6D*+TXV A*VC950905CXB* 34,600 24,800 15.50 12.00 1,150 5620664 CA*F3642*6D*+TXV G*VC950905CXB* 34,600 24,800 15.50 12.00 1,150 5620665 See Notes on Page 29. SS-DSXC16 www.goodmanmfg.com 21 Product Specifications AHRI Ratings (cont.) Indoor Units Outdoor Unit Coils/Air Handlers CA*F3642*6D*+TXV DSXC16 0361A* (cont.) Cooling Ratings Furnaces G*VC951155DXB* Total¹ Sens.¹ SEER² EER³ 34,600 24,800 16.00 12.30 CFM AHRI # 1,150 5620683 CA*F3642*6D*+TXV A*VM960604CXB* 34,600 24,800 16.00 12.00 1,100 5620694 CA*F3642*6D*+TXV G*VM960604CXB* 34,600 24,800 16.00 12.00 1,100 5620695 CA*F3642*6D*+TXV A*VM960805CXB* 34,600 24,800 15.50 12.00 1,150 5620708 CA*F3642*6D*+TXV G*VM960805CXB* 34,600 24,800 15.50 12.00 1,150 5620709 CA*F3642*6D*+TXV G*VM961005DXB* 34,600 24,800 16.00 12.30 1,150 5620727 CA*F3642*6D*+TXV G*VM961155DXB* 34,600 24,800 16.00 12.30 1,150 5620735 CA*F3642*6D*+TXV A*VC80805C*B* 35,000 25,200 16.00 12.50 1,190 6497652 CA*F3642*6D*+TXV A*VC950453BXB* 34,000 24,400 15.50 12.00 1,130 6497653 CA*F3642*6D*+TXV A*VC950704CXB* 34,600 24,800 15.50 12.00 1,100 6497654 CA*F3642*6D*+TXV A*VC950905DXB* 34,600 24,800 16.00 12.25 1,150 6497655 CA*F3642*6D*+TXV A*VC950915DXB* 34,600 24,800 15.50 12.00 1,150 6497656 CA*F3642*6D*+TXV A*VC951155DXB* 34,600 24,800 16.00 12.30 1,150 6497657 CA*F3642*6D*+TXV A*VM960603BXB* 34,000 24,400 15.50 12.00 1,130 6497658 CA*F3642*6D*+TXV A*VM960805DXB* 34,600 24,800 15.50 12.00 1,150 6497659 CA*F3642*6D*+TXV A*VM961005DXB* 34,600 24,800 16.00 12.30 1,150 6497660 CA*F3642*6D*+TXV A*VM961155DXB* 34,600 24,800 16.00 12.30 1,150 6497661 CA*F3642*6D*+TXV ADVC80603B*B* 34,000 24,400 16.00 12.50 1,190 6497662 CA*F3642*6D*+TXV ADVC80805C*B* 35,000 25,200 16.00 12.50 1,190 6497663 CA*F3642*6D*+TXV G*VC80805C*B* 35,000 25,200 16.00 12.50 1,190 6497664 CA*F3642*6D*+TXV G*VC950453BXB* 34,000 24,400 16.00 12.20 1,130 6497665 CA*F3642*6D*+TXV G*VC950905DXB* 34,600 24,800 16.00 12.25 1,150 6497666 CA*F3642*6D*+TXV G*VC950915DXB* 34,600 24,800 15.50 12.00 1,150 6497667 CA*F3642*6D*+TXV G*VM960603BXB* 34,000 24,400 16.00 12.20 1,130 6497668 CA*F3642*6D*+TXV G*VM960805DXB* 34,600 24,800 15.50 12.00 1,150 6497669 34,000 24,400 14.50 11.50 1,200 5357197 CA*F3743*6D*+EEP+TXV CA*F3743*6D*+MBVC1600**-1A*+TXV 35,000 25,200 16.00 12.50 1,100 4415027 CA*F3743*6D*+TXV G*VC91155DXA* 34,600 24,800 15.50 12.20 1,150 4415037 CA*F3743*6D*+TXV A*VC80604B*B* 34,000 24,400 16.00 12.50 1,220 5038932 CA*F3743*6D*+TXV G*VC80604B*B* 34,000 24,400 16.00 12.50 1,220 5039113 CA*F3743*6D*+TXV G*VC950704CXB* 34,600 24,800 16.00 12.30 1,100 5620652 CA*F3743*6D*+TXV A*VC950714CXB* 34,600 24,800 16.00 12.30 1,100 5620660 CA*F3743*6D*+TXV G*VC950714CXB* 34,600 24,800 16.00 12.30 1,100 5620661 CA*F3743*6D*+TXV A*VC950905CXB* 34,600 24,800 16.00 12.00 1,150 5620666 CA*F3743*6D*+TXV G*VC950905CXB* 34,600 24,800 16.00 12.00 1,150 5620667 CA*F3743*6D*+TXV G*VC950905DXB* 34,600 24,800 16.00 12.50 1,150 5620674 CA*F3743*6D*+TXV A*VC950915DXB* 34,600 24,800 16.00 12.50 1,150 5620679 CA*F3743*6D*+TXV G*VC950915DXB* 34,600 24,800 16.00 12.50 1,150 5620680 CA*F3743*6D*+TXV G*VC951155DXB* 34,600 24,800 16.00 12.50 1,150 5620684 CA*F3743*6D*+TXV A*VM960604CXB* 34,600 24,800 16.00 12.50 1,100 5620696 CA*F3743*6D*+TXV G*VM960604CXB* 34,600 24,800 16.00 12.50 1,100 5620697 CA*F3743*6D*+TXV A*VM960805CXB* 34,600 24,800 16.00 12.00 1,150 5620710 CA*F3743*6D*+TXV G*VM960805CXB* 34,600 24,800 16.00 12.00 1,150 5620711 CA*F3743*6D*+TXV G*VM960805DXB* 34,600 24,800 16.00 12.50 1,150 5620720 CA*F3743*6D*+TXV G*VM961005DXB* 34,600 24,800 16.00 12.50 1,150 5620728 See Notes on Page 29. 22 www.goodmanmfg.com SS-DSXC16 Product Specifications AHRI Ratings (cont.) Indoor Units Outdoor Unit Coils/Air Handlers Cooling Ratings Furnaces Sens.¹ SEER² EER³ CFM AHRI # CA*F3743*6D*+TXV G*VM961155DXB* 34,600 24,800 16.00 12.50 1,150 5620736 CA*F3743*6D*+TXV A*VC950453BXB* 34,000 24,400 15.50 12.00 1,130 5696602 CA*F3743*6D*+TXV A*VC80805C*B* 34,000 24,400 16.00 12.50 1,190 6497670 CA*F3743*6D*+TXV A*VC950704CXB* 34,000 24,400 16.00 12.50 1,150 6497671 CA*F3743*6D*+TXV A*VC950905DXB* 34,000 24,400 16.00 12.50 1,150 6497672 CA*F3743*6D*+TXV A*VC951155DXB* 34,000 24,400 16.00 12.50 1,150 6497673 CA*F3743*6D*+TXV A*VM961005DXB* 34,000 24,400 16.00 12.50 1,150 6497674 CA*F3743*6D*+TXV A*VM961155DXB* 34,000 24,400 16.00 12.50 1,150 6497675 CA*F3743*6D*+TXV ADVC80805C*B* 34,000 24,400 16.00 12.50 1,190 6497676 CA*F3743*6D*+TXV G*VC80805C*B* 34,000 24,400 16.00 12.50 1,190 6497677 CA*F3743*6D*+TXV A*VM960603BXB* 34,000 24,400 15.50 12.00 1,130 6603420 CA*F3743*6D*+TXV G*VM960603BXB* 34,000 24,400 15.50 12.00 1,130 6603421 35,000 25,200 14.50 11.50 1,200 5357198 CA*F4860*6D*+EEP+TXV DSXC16 0361A* (cont.) Total¹ CA*F4860*6D*+TXV G*VC91155DXA* 35,000 25,200 15.50 12.20 1,100 3880423 CA*F4860*6D*+TXV A*VC80604B*B* 34,600 24,800 16.00 12.50 1,220 5039011 CA*F4860*6D*+TXV G*VC80604B*B* 34,600 24,800 16.00 12.50 1,220 5039221 CA*F4860*6D*+TXV G*VC950453BXB* 34,600 24,800 16.00 12.20 1,130 5620645 CA*F4860*6D*+TXV G*VC950704CXB* 34,600 24,800 16.00 12.30 1,100 5620653 CA*F4860*6D*+TXV A*VC950714CXB* 34,600 24,800 16.00 12.30 1,100 5620662 CA*F4860*6D*+TXV G*VC950714CXB* 34,600 24,800 16.00 12.30 1,100 5620663 CA*F4860*6D*+TXV G*VC950905CXB* 35,000 25,200 15.50 12.00 1,150 5620668 CA*F4860*6D*+TXV G*VC950905DXB* 35,000 25,200 16.00 12.50 1,150 5620675 CA*F4860*6D*+TXV A*VC950915DXB* 35,000 25,200 16.00 12.50 1,150 5620681 CA*F4860*6D*+TXV G*VC950915DXB* 35,000 25,200 16.00 12.50 1,150 5620682 CA*F4860*6D*+TXV G*VC951155DXB* 34,600 24,800 16.00 12.50 1,150 5620685 CA*F4860*6D*+TXV G*VM960603BXB* 34,600 24,800 16.00 12.20 1,130 5620689 CA*F4860*6D*+TXV A*VM960604CXB* 34,600 24,800 16.00 12.30 1,100 5620698 CA*F4860*6D*+TXV G*VM960604CXB* 34,600 24,800 16.00 12.30 1,100 5620699 CA*F4860*6D*+TXV G*VM960805CXB* 35,000 25,200 15.50 12.00 1,150 5620712 CA*F4860*6D*+TXV G*VM960805DXB* 35,000 25,200 16.00 12.50 1,150 5620721 CA*F4860*6D*+TXV G*VM961005DXB* 34,600 24,800 16.00 12.50 1,150 5620729 CA*F4860*6D*+TXV G*VM961155DXB* 34,600 24,800 16.00 12.50 1,150 5620737 CA*F4860*6D*+TXV A*VC80805C*B* 35,000 25,200 16.00 12.50 1,190 6497678 CA*F4860*6D*+TXV A*VC950453BXB* 35,000 25,200 16.00 12.20 1,130 6497679 CA*F4860*6D*+TXV A*VC950704CXB* 34,600 24,800 16.00 12.20 1,100 6497680 CA*F4860*6D*+TXV A*VC950905CXB* 35,000 25,200 15.50 12.00 1,150 6497681 CA*F4860*6D*+TXV A*VC950905DXB* 35,000 25,200 16.00 12.50 1,150 6497682 CA*F4860*6D*+TXV A*VC951155DXB* 35,000 25,200 16.00 12.50 1,150 6497683 CA*F4860*6D*+TXV A*VM960603BXB* 35,000 25,200 16.00 12.20 1,130 6497684 CA*F4860*6D*+TXV A*VM960805CXB* 35,000 25,200 15.50 12.00 1,150 6497685 CA*F4860*6D*+TXV A*VM960805DXB* 35,000 25,200 15.50 12.00 1,150 6497686 CA*F4860*6D*+TXV A*VM961005DXB* 35,000 25,200 16.00 12.50 1,150 6497687 CA*F4860*6D*+TXV A*VM961155DXB* 35,000 25,200 16.00 12.50 1,150 6497688 CA*F4860*6D*+TXV ADVC80805C*B* 35,000 25,200 16.00 12.50 1,190 6497689 CA*F4860*6D*+TXV G*VC80805C*B* 35,000 25,200 16.00 12.50 1,190 6497690 CA*F4961*6D*+TXV A*VM960805CXB* 35,000 25,200 16.00 12.50 1,200 5620713 CA*F4961*6D*+TXV G*VM960805CXB* 35,000 25,200 16.00 12.50 1,200 5620714 CAPT3743*4A* A*VM960603BXB* 34,000 24,400 15.50 12.00 1,130 6603422 CAPT3743*4A* G*VM960603BXB* 34,000 24,400 15.50 12.00 1,130 6603423 See Notes on Page 29. SS-DSXC16 www.goodmanmfg.com 23 Product Specifications AHRI Ratings (cont.) Indoor Units Outdoor Unit Coils/Air Handlers Cooling Ratings Furnaces CHPF3642C6C*+MBVC1600**-1A*+TXV CHPF3642C6C*+TXV G*VC80604B*B* Sens.¹ SEER² EER³ CFM AHRI # 34,600 24,800 16.00 12.50 1,200 3654024 34,000 24,400 15.50 12.00 1,220 5038934 CHPF3642C6C*+TXV A*VC80604B*B* 34,000 24,400 15.50 12.00 1,220 5039093 CHPF3642C6C*+TXV G*VC950453BXB* 34,000 24,400 15.50 12.00 1,130 5620646 CHPF3642C6C*+TXV G*VC950704CXB* 34,600 24,800 16.00 12.00 1,100 5620654 CHPF3642C6C*+TXV G*VC950905CXB* 34,600 24,800 16.00 12.00 1,150 5620669 CHPF3642C6C*+TXV G*VM960603BXB* 34,000 24,400 15.50 12.00 1,130 5620690 CHPF3642C6C*+TXV A*VM960604CXB* 34,600 24,800 16.00 12.00 1,100 5620700 CHPF3642C6C*+TXV G*VM960604CXB* 34,600 24,800 16.00 12.00 1,100 5620701 CHPF3642C6C*+TXV G*VM960805CXB* 34,600 24,800 16.00 12.00 1,150 5620715 CHPF3642C6C*+TXV G*VM960805DXB* 34,600 24,800 16.00 12.50 1,150 5620722 CHPF3642C6C*+TXV G*VM961005DXB* 34,600 24,800 16.00 12.50 1,150 5620730 CHPF3642C6C*+TXV G*VM961155DXB* 34,600 24,800 16.00 12.50 1,150 5620738 CHPF3642C6C*+TXV A*VC950453BXB* 34,000 24,400 15.50 12.00 1,130 5696601 CHPF3642C6C*+TXV A*VC80805C*B* 34,600 24,800 16.00 12.50 1,190 6497691 CHPF3642C6C*+TXV A*VC950704CXB* 34,600 24,800 16.00 12.00 1,100 6497692 CHPF3642C6C*+TXV G*VC80805C*B* 34,600 24,800 16.00 12.50 1,190 6497693 35,000 25,200 16.00 12.80 1,200 3654036 G*VC950905CXB* 34,600 24,800 16.00 12.00 1,150 5620670 CHPF3642D6C*+MBVC2000**-1A*+TXV CHPF3642D6C*+TXV DSXC16 0361A* (cont.) Total¹ CHPF3642D6C*+TXV G*VC950905DXB* 34,600 24,800 16.00 12.50 1,150 5620676 CHPF3642D6C*+TXV G*VC951155DXB* 34,600 24,800 16.00 12.50 1,150 5620686 CHPF3642D6C*+TXV G*VM960805CXB* 34,600 24,800 16.00 12.00 1,150 5620716 CHPF3642D6C*+TXV G*VM960805DXB* 34,600 24,800 16.00 12.50 1,150 5620723 CHPF3642D6C*+TXV G*VM961005DXB* 34,600 24,800 16.00 12.50 1,150 5620731 CHPF3642D6C*+TXV G*VM961155DXB* 34,600 24,800 16.00 12.50 1,150 5620739 CHPF3642D6C*+TXV A*VC950905CXB* 34,600 24,800 16.00 12.00 1,150 6497694 CHPF3642D6C*+TXV A*VC950905DXB* 34,600 24,800 16.00 12.50 1,150 6497695 CHPF3642D6C*+TXV A*VC951155DXB* 34,600 24,800 16.00 12.50 1,150 6497696 CHPF3642D6C*+TXV A*VM960805CXB* 34,600 24,800 16.00 12.00 1,150 6497697 CHPF3642D6C*+TXV A*VM960805DXB* 34,600 24,800 16.00 12.00 1,150 6497698 CHPF3642D6C*+TXV A*VM961005DXB* 34,600 24,800 16.00 12.50 1,150 6497699 CHPF3642D6C*+TXV A*VM961155DXB* 34,600 24,800 16.00 12.50 1,150 6497700 CHPF3743C6B*+EEP+TXV 34,000 24,400 14.50 11.50 1,200 5357199 CHPF3743C6B*+MBVC1600**-1A*+TXV 34,600 24,800 16.00 12.50 1,200 3654042 CHPF3743C6B*+MBVC2000**-1A*+TXV 35,000 25,200 16.00 12.80 1,200 6497701 34,000 24,400 15.50 12.00 1,220 5038935 CHPF3743C6B*+TXV G*VC80604B*B* CHPF3743C6B*+TXV A*VC80604B*B* 34,000 24,400 15.50 12.00 1,220 5039222 CHPF3743C6B*+TXV G*VC950453BXB* 34,000 24,400 16.00 12.50 1,130 5620647 CHPF3743C6B*+TXV G*VC950704CXB* 34,600 24,800 16.00 12.00 1,100 5620655 CHPF3743C6B*+TXV G*VC950905CXB* 34,600 24,800 16.00 12.00 1,150 5620671 CHPF3743C6B*+TXV G*VM960603BXB* 34,000 24,400 16.00 12.50 1,130 5620691 CHPF3743C6B*+TXV A*VM960604CXB* 34,600 24,800 16.00 12.00 1,100 5620702 CHPF3743C6B*+TXV G*VM960604CXB* 34,600 24,800 16.00 12.00 1,100 5620703 CHPF3743C6B*+TXV G*VM960805CXB* 34,600 24,800 16.00 12.00 1,150 5620717 CHPF3743C6B*+TXV G*VM960805DXB* 34,600 24,800 16.00 12.50 1,150 5620724 CHPF3743C6B*+TXV G*VM961005DXB* 34,600 24,800 16.00 12.50 1,150 5620732 CHPF3743C6B*+TXV G*VM961155DXB* 34,600 24,800 16.00 12.50 1,150 5620740 CHPF3743C6B*+TXV A*VC80805C*B* 34,600 24,800 16.00 12.50 1,190 6497702 CHPF3743C6B*+TXV A*VC950453BXB* 34,000 24,400 16.00 12.20 1,130 6497703 See Notes on Page 29. 24 www.goodmanmfg.com SS-DSXC16 Product Specifications AHRI Ratings (cont.) Indoor Units Outdoor Unit Coils/Air Handlers Cooling Ratings Furnaces Sens.¹ SEER² EER³ CFM AHRI # CHPF3743C6B*+TXV A*VC950704CXB* 34,600 24,800 16.00 12.00 1,100 6497704 CHPF3743C6B*+TXV A*VC950905CXB* 34,600 24,800 16.00 12.00 1,150 6497705 CHPF3743C6B*+TXV A*VC950905DXB* 34,600 24,800 16.00 12.50 1,150 6497706 CHPF3743C6B*+TXV A*VC951155DXB* 34,600 24,800 16.00 12.50 1,150 6497707 CHPF3743C6B*+TXV A*VM960603BXB* 34,000 24,400 16.00 12.20 1,130 6497708 CHPF3743C6B*+TXV A*VM960805CXB* 34,600 24,800 16.00 12.00 1,150 6497709 CHPF3743C6B*+TXV A*VM960805DXB* 34,600 24,800 16.00 12.00 1,150 6497710 CHPF3743C6B*+TXV A*VM961005DXB* 34,600 24,800 16.00 12.50 1,150 6497711 CHPF3743C6B*+TXV A*VM961155DXB* 34,600 24,800 16.00 12.50 1,150 6497712 CHPF3743C6B*+TXV G*VC80805C*B* 34,600 24,800 16.00 12.50 1,190 6497713 35,000 25,200 16.00 12.80 1,200 3654056 34,000 24,400 16.00 12.50 1,220 5038828 CHPF3743D6B*+MBVC2000**-1A*+TXV CHPF3743D6B*+TXV DSXC16 0361A* (cont.) Total¹ G*VC80604B*B* CHPF3743D6B*+TXV A*VC80604B*B* 34,000 24,400 16.00 12.50 1,220 5039094 CHPF3743D6B*+TXV G*VC950453BXB* 34,000 24,400 16.00 12.50 1,130 5620648 CHPF3743D6B*+TXV G*VC950704CXB* 34,000 24,400 16.00 12.50 1,100 5620656 CHPF3743D6B*+TXV G*VC950905CXB* 34,600 24,800 16.00 12.00 1,150 5620672 CHPF3743D6B*+TXV G*VC950905DXB* 34,600 24,800 16.00 12.50 1,150 5620677 CHPF3743D6B*+TXV G*VC951155DXB* 34,600 24,800 16.00 12.50 1,150 5620687 CHPF3743D6B*+TXV G*VM960603BXB* 34,000 24,400 16.00 12.50 1,130 5620692 CHPF3743D6B*+TXV A*VM960604CXB* 34,000 24,400 16.00 12.30 1,100 5620704 CHPF3743D6B*+TXV G*VM960604CXB* 34,000 24,400 16.00 12.50 1,100 5620705 CHPF3743D6B*+TXV G*VM960805CXB* 34,600 24,800 16.00 12.00 1,150 5620718 CHPF3743D6B*+TXV G*VM960805DXB* 34,600 24,800 16.00 12.50 1,150 5620725 CHPF3743D6B*+TXV G*VM961005DXB* 34,600 24,800 16.00 12.50 1,150 5620733 CHPF3743D6B*+TXV G*VM961155DXB* 34,600 24,800 16.00 12.50 1,150 5620741 CHPF3743D6B*+TXV A*VC80805C*B* 34,000 24,400 16.00 12.50 1,190 6497714 CHPF3743D6B*+TXV A*VC950453BXB* 34,000 24,400 16.00 12.20 1,130 6497715 CHPF3743D6B*+TXV A*VC950704CXB* 34,000 24,400 16.00 12.20 1,100 6497716 CHPF3743D6B*+TXV A*VC950905CXB* 34,600 24,800 16.00 12.00 1,150 6497717 CHPF3743D6B*+TXV A*VC950905DXB* 34,600 24,800 16.00 12.50 1,150 6497718 CHPF3743D6B*+TXV A*VC951155DXB* 34,600 24,800 16.00 12.50 1,150 6497719 CHPF3743D6B*+TXV A*VM960603BXB* 34,000 24,400 16.00 12.20 1,130 6497720 CHPF3743D6B*+TXV A*VM960805CXB* 34,600 24,800 16.00 12.00 1,150 6497721 CHPF3743D6B*+TXV A*VM960805DXB* 34,600 24,800 16.00 12.00 1,150 6497722 CHPF3743D6B*+TXV A*VM961005DXB* 34,600 24,800 16.00 12.50 1,150 6497723 CHPF3743D6B*+TXV A*VM961155DXB* 34,600 24,800 16.00 12.50 1,150 6497724 CHPF3743D6B*+TXV G*VC80805C*B* 34,000 24,400 16.00 12.50 1,190 6497725 35,000 25,200 14.50 11.50 1,200 5357200 CHPF4860D6D*+EEP+TXV CHPF4860D6D*+TXV G*VC80604B*B* 34,600 24,800 16.00 12.50 1,220 5038829 CHPF4860D6D*+TXV A*VC80604B*B* 34,600 24,800 16.00 12.50 1,220 5039095 CHPF4860D6D*+TXV G*VC950453BXB* 34,600 24,800 16.00 12.50 1,130 5620649 CHPF4860D6D*+TXV G*VC950704CXB* 35,000 25,200 16.00 12.50 1,100 5620657 CHPF4860D6D*+TXV G*VC950905CXB* 35,000 25,200 16.00 12.00 1,150 5620673 CHPF4860D6D*+TXV G*VC950905DXB* 35,000 25,200 16.00 12.50 1,150 5620678 CHPF4860D6D*+TXV G*VC951155DXB* 35,000 25,200 16.00 12.50 1,150 5620688 CHPF4860D6D*+TXV G*VM960603BXB* 34,600 24,800 16.00 12.50 1,130 5620693 CHPF4860D6D*+TXV A*VM960604CXB* 35,000 25,200 16.00 12.30 1,100 5620706 CHPF4860D6D*+TXV G*VM960604CXB* 35,000 25,200 16.00 12.50 1,100 5620707 CHPF4860D6D*+TXV G*VM960805CXB* 35,000 25,200 16.00 12.00 1,150 5620719 See Notes on Page 29. SS-DSXC16 www.goodmanmfg.com 25 Product Specifications AHRI Ratings (cont.) Indoor Units Outdoor Unit DSXC16 0361A* (cont.) Coils/Air Handlers Cooling Ratings Furnaces Sens.¹ SEER² EER³ CFM AHRI # CHPF4860D6D*+TXV G*VM960805DXB* 35,000 25,200 16.00 12.50 1,150 5620726 CHPF4860D6D*+TXV G*VM961005DXB* 35,000 25,200 16.00 12.50 1,150 5620734 CHPF4860D6D*+TXV G*VM961155DXB* 35,000 25,200 16.00 12.50 1,150 5620742 CHPF4860D6D*+TXV A*VC80805C*B* 34,600 24,800 16.00 12.50 1,190 6497726 CHPF4860D6D*+TXV A*VC950453BXB* 34,600 24,800 16.00 12.20 1,130 6497727 CHPF4860D6D*+TXV A*VC950704CXB* 35,000 25,200 16.00 12.20 1,100 6497728 CHPF4860D6D*+TXV A*VC950905CXB* 35,000 25,200 16.00 12.00 1,150 6497729 CHPF4860D6D*+TXV A*VC950905DXB* 35,000 25,200 16.00 12.50 1,150 6497730 CHPF4860D6D*+TXV A*VC951155DXB* 35,000 25,200 16.00 12.50 1,150 6497731 CHPF4860D6D*+TXV A*VM960603BXB* 34,600 24,800 16.00 12.20 1,130 6497732 CHPF4860D6D*+TXV A*VM960805CXB* 35,000 25,200 16.00 12.00 1,150 6497733 CHPF4860D6D*+TXV A*VM960805DXB* 35,000 25,200 16.00 12.00 1,150 6497734 CHPF4860D6D*+TXV A*VM961005DXB* 35,000 25,200 16.00 12.50 1,150 6497735 CHPF4860D6D*+TXV A*VM961155DXB* 35,000 25,200 16.00 12.50 1,150 6497736 CHPF4860D6D*+TXV G*VC80805C*B* 34,600 24,800 16.00 12.50 1,190 6497737 CSCF3642N6D*+TXV G*VC950453BXB* 34,000 24,400 16.00 12.00 1,200 5620650 CSCF3642N6D*+TXV A*VC950453BXB* 34,000 24,400 16.00 12.00 1,200 6497738 CSCF3642N6D*+TXV A*VC950704CXB* 34,200 24,600 16.00 12.00 1,225 6497739 CSCF3642N6D*+TXV A*VC950905CXB* 34,600 24,800 16.00 12.00 1,150 6497740 CSCF3642N6D*+TXV A*VC950905DXB* 34,600 24,800 16.00 12.00 1,150 6497741 CSCF3642N6D*+TXV A*VC951155DXB* 34,600 24,800 16.00 12.00 1,225 6497742 CSCF4860N6D*+EEP+TXV 35,000 25,200 14.50 11.50 1,200 5357202 AVPTC48D14A* 46,000 34,600 15.50 12.00 1,575 5924365 AVPTC60D14A* 45,500 34,200 16.00 12.00 1,430 6687799 CA*F4860*6D*+EEP+TXV 47,000 35,200 14.50 12.00 1,675 5357203 CA*F4860*6D*+MBVC1600**-1A*+TXV 46,000 34,600 15.00 12.00 1,600 6497743 CA*F4860*6D*+MBVC2000**-1A*+TXV CA*F4860*6D*+TXV DSXC16 0481B* Total¹ G*VC91155DXA* 47,000 35,200 16.00 12.50 1,600 4559576 45,500 34,200 15.50 11.50 1,400 4172484 CA*F4860*6D*+TXV A*VC81005C*B* 46,000 34,600 16.00 12.00 1,370 5038813 CA*F4860*6D*+TXV A*VC80805C*B* 46,000 34,600 16.00 12.30 1,390 5038832 CA*F4860*6D*+TXV G*VC80604B*B* 45,500 34,200 15.00 12.00 1,400 5039096 CA*F4860*6D*+TXV G*VC81005C*B* 46,000 34,600 16.00 12.00 1,370 5039097 CA*F4860*6D*+TXV ADVC80805C*B* 46,000 34,600 16.00 12.30 1,380 5039098 CA*F4860*6D*+TXV ADVC81005C*B* 46,000 34,600 16.00 12.00 1,410 5039099 CA*F4860*6D*+TXV A*VC80604B*B* 45,500 34,200 15.00 12.00 1,400 5039115 CA*F4860*6D*+TXV G*VC80805C*B* 46,000 34,600 16.00 12.30 1,390 5039223 CA*F4860*6D*+TXV A*VC950704CXB* 45,500 34,200 15.00 12.00 1,400 5620743 CA*F4860*6D*+TXV G*VC950704CXB* 45,500 34,200 15.00 12.00 1,400 5620744 CA*F4860*6D*+TXV A*VC950905DXB* 46,000 34,600 16.00 12.30 1,400 5620749 CA*F4860*6D*+TXV G*VC950905DXB* 46,000 34,600 16.00 12.30 1,400 5620750 CA*F4860*6D*+TXV A*VC951155DXB* 46,000 34,600 16.00 12.50 1,400 5620755 CA*F4860*6D*+TXV G*VC951155DXB* 46,000 34,600 16.00 12.30 1,400 5620756 CA*F4860*6D*+TXV A*VM961005DXB* 46,000 34,600 16.00 12.50 1,400 5620761 CA*F4860*6D*+TXV G*VM961005DXB* 46,000 34,600 16.00 12.30 1,400 5620762 CA*F4860*6D*+TXV A*VM961155DXB* 46,000 34,600 16.00 12.50 1,400 5620767 CA*F4860*6D*+TXV G*VM961155DXB* 46,000 34,600 16.00 12.30 1,400 5620768 CA*F4860*6D*+TXV A*VC950915DXB* 46,000 34,600 15.00 11.50 1,400 6497744 See Notes on Page 29. 26 www.goodmanmfg.com SS-DSXC16 Product Specifications AHRI Ratings (cont.) Indoor Units Outdoor Unit DSXC16 0481B* (cont.) Coils/Air Handlers Cooling Ratings Furnaces Total¹ Sens.¹ SEER² EER³ CFM AHRI # CA*F4860*6D*+TXV G*VC950905CXB* 46,000 34,600 15.00 11.50 1,400 6497745 CA*F4860*6D*+TXV G*VC950915DXB* 46,000 34,600 15.00 11.50 1,400 6497746 CA*F4961*6D*+EEP+TXV 48,000 36,000 14.50 12.00 1,675 5357204 CA*F4961*6D*+MBVC1600**-1A*+TXV 46,000 34,600 15.00 12.00 1,400 4431661 CA*F4961*6D*+MBVC2000**-1A*+TXV 47,000 35,200 16.00 12.50 1,400 4431662 CA*F4961*6D*+TXV G*VC91155DXA* 45,500 34,200 15.50 12.00 1,350 4431704 CA*F4961*6D*+TXV ADVC80805C*B* 47,000 35,200 16.00 12.50 1,380 5038811 CA*F4961*6D*+TXV A*VC80805C*B* 47,000 35,200 16.00 12.50 1,390 5038814 CA*F4961*6D*+TXV G*VC80805C*B* 47,000 35,200 16.00 12.50 1,390 5038933 CA*F4961*6D*+TXV ADVC81005C*B* 46,500 35,000 16.00 12.00 1,410 5038936 CA*F4961*6D*+TXV G*VC81005C*B* 46,500 35,000 16.00 12.00 1,370 5039012 CA*F4961*6D*+TXV G*VC80604B*B* 46,000 34,600 16.00 12.30 1,400 5039100 CA*F4961*6D*+TXV A*VC80604B*B* 46,000 34,600 16.00 12.30 1,400 5039101 CA*F4961*6D*+TXV A*VC81005C*B* 46,500 35,000 16.00 12.00 1,370 5039225 CA*F4961*6D*+TXV A*VC950704CXB* 46,500 35,000 15.00 12.00 1,350 5620745 CA*F4961*6D*+TXV G*VC950704CXB* 46,500 35,000 15.00 12.00 1,350 5620746 CA*F4961*6D*+TXV A*VC950905DXB* 47,000 35,200 16.00 12.50 1,350 5620751 CA*F4961*6D*+TXV G*VC950905DXB* 47,000 35,200 16.00 12.50 1,350 5620752 CA*F4961*6D*+TXV A*VC951155DXB* 47,000 35,200 16.00 12.50 1,350 5620757 CA*F4961*6D*+TXV G*VC951155DXB* 47,000 35,200 16.00 12.50 1,350 5620758 CA*F4961*6D*+TXV A*VM961005DXB* 47,000 35,200 16.00 12.50 1,350 5620763 CA*F4961*6D*+TXV G*VM961005DXB* 47,000 35,200 16.00 12.50 1,350 5620764 CA*F4961*6D*+TXV A*VM961155DXB* 47,000 35,200 16.00 12.50 1,350 5620769 CA*F4961*6D*+TXV G*VM961155DXB* 47,000 35,200 16.00 12.50 1,350 5620770 CA*F4961*6D*+TXV A*VM960805CXB* 47,000 35,200 15.50 12.00 1,350 6497747 CHPF4860D6D*+EEP+TXV 48,000 36,000 14.50 12.00 1,675 5357205 CHPF4860D6D*+MBVC1600**-1A*+TXV 46,000 34,600 15.00 12.00 1,400 4172507 CHPF4860D6D*+MBVC2000**-1A*+TXV 47,000 35,200 16.00 12.50 1,400 4172508 45,500 34,200 15.50 12.00 1,400 5038812 CHPF4860D6D*+TXV G*VC80604B*B* CHPF4860D6D*+TXV G*VC81005C*B* 45,500 34,200 15.50 12.00 1,370 5038830 CHPF4860D6D*+TXV A*VC80805C*B* 45,500 34,200 15.50 12.00 1,390 5038833 CHPF4860D6D*+TXV A*VC80604B*B* 45,500 34,200 15.50 12.00 1,400 5039102 CHPF4860D6D*+TXV G*VC80805C*B* 45,500 34,200 15.50 12.00 1,390 5039224 CHPF4860D6D*+TXV A*VC81005C*B* 45,500 34,200 15.50 12.00 1,370 5039226 CHPF4860D6D*+TXV A*VC950704CXB* 46,000 34,600 15.50 12.00 1,350 5620747 CHPF4860D6D*+TXV G*VC950704CXB* 46,000 34,600 15.50 12.00 1,350 5620748 CHPF4860D6D*+TXV A*VC950905DXB* 47,000 35,200 16.00 12.30 1,350 5620753 CHPF4860D6D*+TXV G*VC950905DXB* 47,000 35,200 16.00 12.30 1,350 5620754 CHPF4860D6D*+TXV A*VC951155DXB* 47,000 35,200 16.00 12.30 1,350 5620759 CHPF4860D6D*+TXV G*VC951155DXB* 47,000 35,200 16.00 12.30 1,350 5620760 CHPF4860D6D*+TXV A*VM961005DXB* 47,000 35,200 16.00 12.30 1,350 5620765 CHPF4860D6D*+TXV G*VM961005DXB* 47,000 35,200 16.00 12.30 1,350 5620766 CHPF4860D6D*+TXV A*VM961155DXB* 47,000 35,200 16.00 12.30 1,350 5620771 CHPF4860D6D*+TXV G*VM961155DXB* 47,000 35,200 16.00 12.30 1,350 5620772 CHPF4860D6D*+TXV G*VC950905CXB* 47,000 35,200 16.00 12.25 1,350 6497748 48,000 36,000 14.50 12.00 1,675 5357206 CSCF4860N6D*+EEP+TXV See Notes on Page 29. SS-DSXC16 www.goodmanmfg.com 27 Product Specifications AHRI Ratings (cont.) Indoor Units Outdoor Unit Coils/Air Handlers Cooling Ratings Furnaces AVPTC60D14A* CA*F4860*6D*+MBVC2000**-1A*+TXV CA*F4860*6D*+TXV DSXC16 0601B* G*VC91155DXA* Total¹ Sens.¹ SEER² EER³ 57,000 42,500 15.50 12.00 CFM AHRI # 1,780 5924366 55,500 41,000 15.50 12.00 1,800 3880338 55,500 41,000 15.50 12.00 1,575 3880462 CA*F4860*6D*+TXV ADVC81005C*B* 55,500 41,000 15.50 12.00 1,550 5038834 CA*F4860*6D*+TXV A*VC80805C*B* 55,500 41,000 15.50 12.00 1,590 5038937 CA*F4860*6D*+TXV A*VC81005C*B* 55,500 41,000 15.50 12.00 1,610 5038965 CA*F4860*6D*+TXV G*VC80805C*B* 55,500 41,000 15.50 12.00 1,590 5039104 CA*F4860*6D*+TXV ADVC80805C*B* 55,500 41,000 15.50 12.00 1,580 5039105 CA*F4860*6D*+TXV G*VC81005C*B* 55,500 41,000 15.50 12.00 1,610 5039227 CA*F4860*6D*+TXV A*VC950905CXB* 55,500 41,000 15.00 11.50 1,575 5620773 CA*F4860*6D*+TXV G*VC950905CXB* 55,500 41,000 15.00 11.50 1,575 5620774 CA*F4860*6D*+TXV A*VC950905DXB* 55,500 41,000 15.50 12.00 1,575 5620779 CA*F4860*6D*+TXV G*VC950905DXB* 55,500 41,000 15.50 12.00 1,575 5620780 CA*F4860*6D*+TXV A*VC950915DXB* 55,500 41,000 15.50 11.50 1,575 5620785 CA*F4860*6D*+TXV G*VC950915DXB* 55,500 41,000 15.50 11.50 1,575 5620786 CA*F4860*6D*+TXV A*VC951155DXB* 55,500 41,000 15.50 12.00 1,575 5620789 CA*F4860*6D*+TXV G*VC951155DXB* 55,500 41,000 15.50 12.00 1,575 5620790 CA*F4860*6D*+TXV A*VM960805CXB* 55,500 41,000 15.00 11.50 1,575 5620795 CA*F4860*6D*+TXV G*VM960805CXB* 55,500 41,000 15.00 11.50 1,575 5620796 CA*F4860*6D*+TXV A*VM960805DXB* 55,500 41,000 15.50 11.50 1,575 5620801 CA*F4860*6D*+TXV G*VM960805DXB* 55,500 41,000 15.50 11.50 1,575 5620802 CA*F4860*6D*+TXV A*VM961005DXB* 55,500 41,000 15.50 12.00 1,575 5620807 CA*F4860*6D*+TXV G*VM961005DXB* 55,500 41,000 15.50 12.00 1,575 5620808 CA*F4860*6D*+TXV A*VM961155DXB* 55,500 41,000 15.50 12.00 1,575 5620813 CA*F4860*6D*+TXV G*VM961155DXB* 55,500 41,000 15.50 12.00 1,575 5620814 56,000 41,500 14.00 11.80 1,550 5357207 CA*F4961*6D*+EEP+TXV CA*F4961*6D*+MBVC2000**-1A*+TXV 57,000 42,500 16.00 12.30 1,800 4431664 CA*F4961*6D*+TXV G*VC91155DXA* 56,000 41,500 15.50 12.00 1,575 4431724 CA*F4961*6D*+TXV G*VC80805C*B* 56,000 41,500 15.50 12.30 1,590 5038815 CA*F4961*6D*+TXV A*VC81005C*B* 56,000 41,500 15.50 12.00 1,610 5038835 CA*F4961*6D*+TXV G*VC81005C*B* 56,000 41,500 15.50 12.00 1,610 5038964 CA*F4961*6D*+TXV A*VC80805C*B* 56,000 41,500 15.50 12.30 1,590 5038966 CA*F4961*6D*+TXV ADVC81005C*B* 56,000 41,500 15.50 12.00 1,550 5039013 CA*F4961*6D*+TXV ADVC80805C*B* 56,000 41,500 15.50 12.30 1,580 5039116 CA*F4961*6D*+TXV A*VC950905CXB* 56,000 41,500 15.50 11.50 1,575 5620775 CA*F4961*6D*+TXV G*VC950905CXB* 56,000 41,500 15.50 11.50 1,575 5620776 CA*F4961*6D*+TXV A*VC950905DXB* 56,000 41,500 15.50 12.30 1,575 5620781 CA*F4961*6D*+TXV G*VC950905DXB* 56,000 41,500 15.50 12.30 1,575 5620782 CA*F4961*6D*+TXV A*VC950915DXB* 56,000 41,500 15.50 12.30 1,575 5620787 CA*F4961*6D*+TXV G*VC950915DXB* 56,000 41,500 15.50 12.30 1,575 5620788 CA*F4961*6D*+TXV A*VC951155DXB* 56,000 41,500 15.50 12.00 1,575 5620791 CA*F4961*6D*+TXV G*VC951155DXB* 56,000 41,500 15.50 12.00 1,575 5620792 CA*F4961*6D*+TXV A*VM960805CXB* 56,000 41,500 15.50 11.50 1,575 5620797 CA*F4961*6D*+TXV G*VM960805CXB* 56,000 41,500 15.50 11.50 1,575 5620798 CA*F4961*6D*+TXV A*VM960805DXB* 56,000 41,500 15.50 12.30 1,575 5620803 See Notes on Page 29. 28 www.goodmanmfg.com SS-DSXC16 Product Specifications AHRI Ratings (cont.) Outdoor Unit Indoor Units Coils/Air Handlers CA*F4961*6D*+TXV Cooling Ratings Furnaces G*VM960805DXB* Sens.¹ SEER² EER³ 56,000 41,500 15.50 12.30 CFM AHRI # 1,575 5620804 CA*F4961*6D*+TXV A*VM961005DXB* 56,000 41,500 15.50 12.00 1,575 5620809 CA*F4961*6D*+TXV G*VM961005DXB* 56,000 41,500 15.50 12.00 1,575 5620810 CA*F4961*6D*+TXV A*VM961155DXB* 56,000 41,500 15.50 12.00 1,575 5620815 CA*F4961*6D*+TXV G*VM961155DXB* 56,000 41,500 15.50 12.00 1,575 5620816 56,000 41,500 14.00 11.80 1,550 5357208 CHPF4860D6D*+EEP+TXV CHPF4860D6D*+MBVC2000**-1A*+TXV DSXC16 0601B* (cont.) Total¹ 57,000 42,500 15.50 12.30 1,800 3798903 CHPF4860D6D*+TXV A*VC81005C*B* 56,000 41,500 15.50 12.00 1,610 5038967 CHPF4860D6D*+TXV G*VC80805C*B* 56,000 41,500 15.50 12.30 1,590 5039014 CHPF4860D6D*+TXV A*VC80805C*B* 56,000 41,500 15.50 12.30 1,590 5039106 CHPF4860D6D*+TXV G*VC81005C*B* 56,000 41,500 15.50 12.00 1,610 5039117 CHPF4860D6D*+TXV A*VC950905CXB* 56,000 41,500 15.50 11.50 1,575 5620777 CHPF4860D6D*+TXV G*VC950905CXB* 56,000 41,500 15.50 11.50 1,575 5620778 CHPF4860D6D*+TXV A*VC950905DXB* 56,000 41,500 15.50 12.30 1,575 5620783 CHPF4860D6D*+TXV G*VC950905DXB* 56,000 41,500 15.50 12.30 1,575 5620784 CHPF4860D6D*+TXV A*VC951155DXB* 56,000 41,500 15.50 12.00 1,575 5620793 CHPF4860D6D*+TXV G*VC951155DXB* 56,000 41,500 15.50 12.00 1,575 5620794 CHPF4860D6D*+TXV A*VM960805CXB* 56,000 41,500 15.50 11.50 1,575 5620799 CHPF4860D6D*+TXV G*VM960805CXB* 56,000 41,500 15.50 11.50 1,575 5620800 CHPF4860D6D*+TXV A*VM960805DXB* 56,000 41,500 15.50 11.50 1,575 5620805 CHPF4860D6D*+TXV G*VM960805DXB* 56,000 41,500 15.50 11.50 1,575 5620806 CHPF4860D6D*+TXV A*VM961005DXB* 56,000 41,500 15.50 12.00 1,575 5620811 CHPF4860D6D*+TXV G*VM961005DXB* 56,000 41,500 15.50 12.00 1,575 5620812 CHPF4860D6D*+TXV A*VM961155DXB* 56,000 41,500 15.50 12.00 1,575 5620817 CHPF4860D6D*+TXV G*VM961155DXB* 56,000 41,500 15.50 12.00 1,575 5620818 56,000 41,500 14.00 11.80 1,550 5357209 CSCF4860N6D*+EEP+TXV ¹ BTU/h ² Seasonal Energy Efficiency Ratio; Certified per AHRI 210/240 @ 80°F/ 67°F/ 95°F ³ Energy Efficiency Ratio @ 80°F/ 67°F/ 95°F Notes • Always check the S&R plate for electrical data on the unit being installed. • When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. • EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay SS-DSXC16 www.goodmanmfg.com 29 Product Specifications Dimensions Model 30 Dimensions W" D" H" DSXC160241A* 29 29 32¼ DSXC160361A* 29 29 38¼ DSXC160481B* 35½ 35½ 36¼ DSXC160601B* 35½ 35½ 38¼ www.goodmanmfg.com SS-DSXC16 Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. ⚠ Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡ Product Specifications Wiring Diagram SS-DSXC16 www.goodmanmfg.com 31 Product Specifications Accessories Model Description DSXC16 024** DSXC16 036** DSXC16 048** DSXC16 060** ABK-20 Anchor Bracket Kit^ X X X X ASC-01 Anti-Short Cycle Kit X X X X B1141643¹ 24V Transformer X X X X CSR-U-1 Hard-start Kit X X X CSR-U-2 Hard-start Kit CSR-U-3 Hard-start Kit FSK01A² Freeze Protection Kit X X X X LSK02A Liquid Line Solenoid Valve X X X X OT18-60A³ Outdoor Thermostat/Lockout Thermostat X X X X TX2N4 TXV Kit X TX2N4A TXV Kit X TX3N4⁴ TXV Kit TX5N4 TXV Kit X X X X X ^ Contains 20 brackets; four brackets needed to anchor unit to pad ¹ This component is included in the CTK01AA communicating thermostat kit. ² Installed on indoor coil ³ Available in 24V legacy mode only. This feature is integrated in the communicating mode. Note: Maximum number of installed accessories at the same time is limited by the size of the unit’s control box. Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2014 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 32 www.goodmanmfg.com SS-DSXC16