Preview only show first 10 pages with watermark. For full document please download

Dt-300 Series Catalog Page

   EMBED


Share

Transcript

NEW! LIGHTING CONTROLS WATTSTOPPER DUAL-TECHNOLOGY OCCUPANCY AND LIGHT SENSOR DT-300 SERIES DESCRIPTION The low-profile DT-300 dual-technology occupancy sensor with light level sensor combines the benefits of passive infrared (PIR) and ultrasonic technologies. The sensor mounts in the ceiling with a flat, unobtrusive appearance and provides 360 degrees of coverage. Using SmartSet™ technology, the DT-300 requires no adjustment at installation. SmartSet™ continuously monitors the controlled space to identify usage patterns. Using this information, it automatically adjusts the time delay and sensitivity settings for optimal performance and energy efficiency. The sensor assigns short delays (as low as 5 minutes) for times when the space is usually vacant, and longer delays (up to 30 minutes) for busier times. The DT-305 is a lower cost version of the DT-300 without isolated relay or light level sensor. DT-300 FEATURES • • • • • SmartSet™ adjusts sensitivity and time delay Walk-through mode turns lights off Ultrasonic diffusion technology LED occupancy indication Pluggable terminal wiring 11 OPERATION In normal operation, the DT-300 turns lighting on when both the PIR and ultrasonic technologies detect occupancy. LIGHTING CONTROLS It can also work with a low voltage switch for manual-on operation. PIR technology senses the difference between infrared energy from a human body in motion and the background space. Ultrasonic technology uses the Doppler principle and high frequency (40 KHz) ultrasound to sense motion. Once lighting is on, detection by either technology holds lighting on. When no occupancy is detected for the length of the time delay, lighting turns off. The DT-300 can also be configured so that one or both technologies are needed to turn lighting on or hold lighting on. SPECIFICATIONS Supply Voltage DT300 DT305 Switch Input Relay Output DT300 Ambient Light DT300 Time Delay Adjust 24 VDC/VAC ±10% 43 mA 24 VDC/VAC ±10% 35 mA Low voltage, momentary for manual ON or OFF operation Isolated SPDT contacts rated for 1A @ 30 VAC/VDC 10 to 300 footcandles (108 to 3230 lux) Coverage Pattern Up to 1000 ft2 (92.9 m2) Sensitivity Adjustment SmartSet™ (automatic) or reduced sensitivity (for PIR sensitivity); ultrasonic sensitivity is variable with trimpot March 2014 SmartSet™ (automatic), fixed (5, 10,15, 20, or 30 minutes), walkthrough, test-mode Ultrasonic Frequency 40kHz Mounting Ceiling tile 4" square junction box with double gang mud ring Dimensions 4.50"Ø x 1.02"D (114.3mm x 25.9mm) Approvals UL and CUL listed file E101196 Weight 1.0 lb (0.46 kg) Warranty 5 years WE MAKE IT EASY. kele.com 888-397-5353 USA 629 NEW! LIGHTING CONTROLS WATTSTOPPER DUAL-TECHNOLOGY OCCUPANCY AND LIGHT SENSOR DT-300 SERIES WIRING Trigger Switch (red) Load Isolated relay outputs Common Normally open contact Normally closed contact Auxiliary relay pack Lighting load Occupancy Logic (black) (blue) Hot Power Pack (black) (white) (red) N (blue) Relay common N.O. N.C. Light level (24VDC) out = ON = OFF Manual switch +24V (in) Common (black) OFF switch Light level lighting load (red) load N Occupancy DT-300 Terminals Hot DT300 Occupancy Power pack Switch Lighting load 11 Either(5) Both Both Both(5) PIR PIR PIR(5) Ultra Ultra Ultra(5) Man. Either Either(30) Man. Both Both(30) Switch# Logic 1 2 3 Standard Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 = walk-through mode LEDs 7 Disabled Enabled Control (24VDC) out Momentary switch Manual switch +24V (in) Common PIR Sensitivity 8 Minimum Maximum/SmartSet DT-305 Terminals DT305 LIGHITING CONTROLS Either(5) Either 5 sec/SmartSet 5 min 10 min 10 min 15 min 15 min 20 min 30 min (blue) (red) Load (black) (black) (red) (white) Hot Either(5) PIR Time Delay 4 5 6 (white) Neutral (red) Line N Both Either Either Either Standard Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 = Factory Setting Control (24VDC) out Momentary Switch Re-trigger (seconds duration) (white) Neutral (red) Line Initial Occupancy Maintain Occupancy DIP SWITCH SETTINGS Occupancy and Light Level Controlled Lighting Notes: Exceeding voltage rating may damage sensor. Shown with BZ-50 power pack (optional). COVERAGE MOUNTING 4" Octagonal J-Box (at least 1.5" deep) Ceiling Ceiling Depluggable terminal PIR Coverage 44' (13.4m) Depluggable terminal Spring clips (2) Rear housing Rear Housing Front cover Screws Front Cover Ultrasonic Coverage J-Box Mount Ceiling Mount 40' x 40' (12m x 12m) ORDERING INFORMATION MODEL DT-300 DT-305 630 888-397-5353 USA DESCRIPTION Dual technology occupancy sensor with isolated relay and light level actuation Dual technology occupancy sensor with 24 VDC control output only (no light level or relay) kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014