Transcript
DT7450MIC-UK DUAL TEC Motion Sensor with Microphone - Installation Instructions
1
4
5
LOCATION
T
T
WIRE
O N
1 2 3
G
C
NC V- V+
6
J1
J1
2.3m (7.5ft)
2 1
OPEN
Range Adjustment
Microphone
Audio Adjustment
Audio Jumper
3
2
Cover Tamper Switch
50 Hz
Test Pads
3
MOUNT
Rear Tamper Breakaway Tab*
*Best if mounted to a stud, solid wood, or with a robust wall anchor.
Normal
Power Up
Red
Green (PIR Active) Yellow (Microwave Active)
Slow Blinking Red
0.3-1.3mm2 (22-16 AWG)
Alarm
Fast Blinking Red
Indicator LEDs Condition Indicator LED
Trouble
Yellow (Microwave Detection) Green (PIR Detection)
H
O N
1 2 3
H
1-3
3-5
Zone Finder
L = Low (pulse count 2)
L
H = High (pulse count 1)
L
1 2 3
O N
60 Hz
O N
M
G
M
G
IDENTIFY COMPONENTS AND SELECT APPROPRIATE SETTINGS
+
+
LED
O N
TAMPER 24 VDC, 10mA
ALARM 24 VDC, 50mA
8 - 16VDC, 30mA
Optional EOL (End of Line) resistor.
REPLACE CIRCUIT BOARD
M
EOL
1 2 3
1 2 3
DT7450MIC-UK DUAL TEC Motion Sensor with Microphone - Installation Instructions ! SET AUDIO GAIN 1. For audio verification, install jumper across pins on J1. (Jumper may be stowed on one pin if audio verification is not used.)
DETECTION PATTERNS Top View
2. For best audio clarity, set Potentiometer to minimum acceptable volume. See table below for initial setting. Note: If using audio verification, do not mount the sensor in a noisy environment. Interface Module Examples
Approximate Potentiometer Setting
APEX Destiny 6100
Minimum
DSC Power 864 with PC5900 AVM
Maximum
Dycon D5000 AVU, CSL CS5000
Maximum
Honeywell Galaxy
30% of maximum
Honeywell UVCM
Maximum
Honeywell Dimension
Maximum
" WALK TEST 1. Ensure switch S2 is set to ON (right). 2. Set Range Adjustment potentiometer to 25%. Replace cover and turn power ON. After the RED LED stops slowly flashing (power up mode), walk test the sensor. 3. Walk through the detection area and observe the LED: RED LED indicates an alarm detection. GREEN LED indicates PIR detection. YELLOW LED indicates microwave detection. 4. If necessary, increase Range Adjustment potentiometer until desired detection range is obtained. 5. Set switch S2 to OFF (left) to disable the LEDs. # ZONE FINDER WALK TEST (OPTIONAL STEP) Use Zone Finder mode to identify the PIR and/or microwave pattern. In Zone Finder mode, the RED LED (alarm) is disabled. The Zone Finder mode times out in 10 minutes.
Side View
1. Ensure switch S2 is set to ON (right). 2. Use a screwdriver to short the TEST PADS for 5 seconds. Replace the cover. 3. Walking through the detection area and observe the LED: GREEN LED indicates PIR detection. YELLOW LED indicates microwave detection. 4. If the detection was not satisfactory, adjust the detection range as described in the Walk Test section. 5. Remove cover and set switch S2 to OFF (left) to disable the LEDs. TROUBLESHOOTING RED LED flashing rapidly indicates a trouble condition. Either a microwave, PIR, or temperature compensation fault is present. Solution: Momentarily power down the sensor, or enter the Zone Finder mode (short test pads for 5 seconds) to invoke a self test. If the trouble does not clear, replace the sensor. (Please check the power, and all wiring before replacing the sensor.)
COMPLIANCE NOTES • For EN 50131-2-4 and PD6662 compliant installations, mount sensor at 2.3m (7.5ft), set sensitivity to H (High), and install cover screw. Suitable for connection to an EN60950 Class II • Limited Power Source in European installations.
APPROVAL LISTINGS
ACCESSORIES
•
CE
Swivel Mount Bracket
•
PD6662
SMB-10 (P/N 0-000-110-01)
•
EN 50131-1 and EN 50131-2-4 Security Grade 2, Environment Class II.
SMB-10C (P/N 0-000-111-01)
Swivel Mount Ceiling Bracket
SMB-10T (P/N 0-000-155-01)
Swivel Mount Bracket w/Tamper EN 50131-1, EN 50131-2-4 & PD6662 Compliant
DT7000-LRLK
Long Range Lens Kit
•
,
DT7450MIC-UK DUAL TEC Motion Sensor with Microphone - Installation Instructions SPECIFICATIONS Range: 50’ x 60’ (15 m x 18 m)
AC Ripple: 3 V peak-to-peak at 12 VDC nominal
Temperature Compensation: Advanced Dual Slope
Alarm Relay: (NC) Form A, 50 mA, 24 VDC, 20 Ohm series resistor
Frequencies: 24.200 GHz (K-band)
PIR Fields of View: 22 long range zones 12 intermediate zones
Tamper Switches: (NC) 10 mA, 24 VDC
PIR White Light Immunity: 6,500 Lux typical
Sensitivity: Low (Pulse Count 2) 3 - 4 steps High (Pulse Count 1) 2 - 3 steps
Microphone Output: 15 V peak-to-peak max; 10 mA max
Fluorescent Light Filter: 50 Hz or 60 Hz, selectable
Dimensions: 4.6” x 2.8” x 1.7” (11.9 cm x 7.1 cm x 4.2 cm)
Power Requirements: 8 - 16 VDC
Operating Temperature: 14° to 131° F (-10° to 55° C), 5% - 95% relative humidity (non-condensing)
Weight: 185.5 g (6.54 oz) Packaged: 236.0 g (8.33 oz)
Current: 28 mA nominal (with LED disabled); 36 mA nominal (with LED enabled); 40 mA max. (during warm up)
Self-Tests: Microwave supervision; PIR self-test; Temperature Compensation
To obtain applicable EU compliance Declaration of Conformities for this product, please refer to our Website, http://www.security.honeywell.com/hsce/international/index.html. For any additional information regarding the compliance of this product to any EU specific requirements, please contact: Quality Assurance Department, Honeywell Security & Custom Electronics, Newhouse Industrial Estate Motherwell, Lanarkshire ML1 5SB, Scotland, United Kingdom. Tel: +44(0)1698 738200 Email: UK64Sales@Honeywell.
6 lower zones 4 look-down zones
DT7450MIC-UK DUAL TEC Motion Sensor with Microphone - Installation Instructions
2007 Honeywell International Inc. Honeywell, IntelliSense and DUAL TEC are registered trademarks of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Made in China.
Please contact your local authorised Honeywell representative for product warranty information. P/N 800-01640 Rev B