Preview only show first 10 pages with watermark. For full document please download

Duct Air Flow Measuring Probe Lightweight, Durable, & Easy To Install Elocity

   EMBED


Share

Transcript

p150:Layout 6 7/8/09 3:48 PM Page 1 Series DAFM Duct Air Flow Measuring Probe Air Velocity Lightweight, Durable, & Easy to Install 1 [25.40] 1/8 [3.18] OUTER RADIUS TO MATCH INNER RADIUS OF DUCT 1 INCH OUTER PERIMETER 1/8 [3.18] INNER RADIUS TO MATCH OUTER RADIUS OF DUCT 4 INCH OUTER PERIMETER 1/8 [3.18] 1/4˝ BARB FITTINGS TO BE CENTERED ON PLATE 1-7/19 [36.51] L 1/2 [12.70] 4 [101.60] 3/8 [9.52] 1-1/16 [52.39] Ø1/4 4X [6.35] 2 [50.80] 1-7/16 [36.51] 1/2 [12.70] 1/2 [12.70] Ø1/4 [6.35] 2X The Model DAFM Duct Air Flow Measuring Probe uses evenly distributed total and static pressure measuring points to deliver an accurate measurement of flow in a duct. The Air Flow Measuring Probe can be completely installed from outside of the duct making it very easy to install. With its lightweight and durable construction in addition to its ease of installation, this product lends itself to being used in the HVAC industry. These air flow measuring probes may be ordered for either round or rectangular ducts. In order to ensure accurate measurements you must determine the number of probes needed for your size duct. If the duct is rectangular, then consult the chart to determine appropriate quantity of probes. If the duct is round, it is only necessary to purchase two probes for any size of duct and mount them perpendicular to each other. L = Smallest Duct Diameter or Length L 1/2 [12.70] 2-1/16 [52.39] Ø1/4 2X [6.35] Ø1/4 4X [6.35] SPECIFICATIONS Wetted Materials: Aluminum with clear anodized finish. Accuracy: ±2% (Note: Field Calibration May Be Required). Temperature Limit: 400ºF (204ºC). Minimum Design Flow: 400 fpm (2.03 m/sec). Maximum Design Flow: 12,000 fpm (60.96 m/sec). Process Connections: 1/4˝ barb. Straight Run Requirements: 5 diameters or longest side dimensions. Model DAFM-000 DAFM-001 DAFM-002 DAFM-003 DAFM-004 DAFM-005 DAFM-006 DAFM-007 DAFM-008 DAFM-009 DAFM-100 DAFM-101 DAFM-102 DAFM-103 DAFM-104 DAFM-105 DAFM-106 DAFM-107 DAFM-108 DAFM-109 Short Duct Dimension <12˝ 12˝ - 23˝ 24˝ - 35˝ 36˝ - 59˝ 60˝ - 89˝ >89˝ Number of Probes 1 3 2 4 6 5 Smallest Duct Diameter Or Length (L) 6˝ (15.24 cm) 8˝ (20.32 cm) 10˝ (25.4 cm) 12˝ (30.48 cm) 14˝ (35.56 cm) 16˝ (40.64 cm) 18˝ (45.72 cm) 20˝ (50.8 cm) 22˝ (55.88 cm) 24˝ (60.96 cm) 6˝ (15.24 cm) 8˝ (20.32 cm) 10˝ (25.4 cm) 12˝ (30.48 cm) 14˝ (35.56 cm) 16˝ (40.64 cm) 18˝ (45.72 cm) 20˝ (50.8 cm) 22˝ (55.88 cm) 24˝ (60.96 cm) Duct Shape Round Round Round Round Round Round Round Round Round Round Rectangular Rectangular Rectangular Rectangular Rectangular Rectangular Rectangular Rectangular Rectangular Rectangular For larger sizes up to 96˝ (243.84 cm), please contact factory. 150 VISIT OUR WEBSITES: www.dwyer-inst.com 3/8 [9.52] 5 [127.00] 6 [152.40] 5 [127.00] 6 [152.40] 1/2 [12.39] 1/2 [12.39] 1/8 [3.18] • www.dwyer-inst.co.uk • www.dwyer-inst.com.au