Duplexvent Flexi Dv3600 Key Features /hr Air Volume

   EMBED


Share

Transcript

Duplexvent FLEXI DV3600 Flexi Line Side Entry - Up to 3800 m3/hr air volume Key Features  Extract up to 3600 m³/hr @ 200 Pa ●  Excellent heat recovery efficiency, up to 95% ●  Versatile unit positioning with floor and ceiling suspended mounting options ●  Low SFP with energy saving EC fans ●  Low noise, refer to NR35 and BB93 standards ●  10 speed digital control with internet and BMS ●  Compliant to BREEAM, Passive House and ErP 2015 regulations ●  2 year warranty + ● 1200 Performance 63 125 250 500 1k 2k 4k 8k Outdoor air e1 50 67 65 46 36 35 28 <25 <25 Supply air e2 70 71 83 72 62 61 54 48 53 Extract air i1 50 66 65 45 38 34 28 <25 <25 Exhaust air i2 69 69 82 71 61 59 53 47 52 Breakout noise 54 56 67 56 49 44 35 <25 <25 dB (A) 63 125 250 500 1k 2k 4k 8k 33 36 46 36 28 <25 <25 <25 <25 To the surrounding STATIC PRESSURE (Pa) Sound Power Level Lw (dB) dB (A) Sound Pressure Level Ld Extract Supply 1000 800 600 400 0 0 Sound pressure level is measured at 3m distance 0 Supply Air Extract Air Maximum air volume @ 200 Pa m3/hr / l/sec 3600 / 1000 3600 / 1000 Air volume @ 250 Pa* m3/hr / l/sec 2000 / 556 2000 / 556 400 400 Nominal voltage V Nominal Power (at operation point)* V 400 400 W 446 397 Max connection power W 1480 1480 Max current A 2.4 2.4 Filters F7 M5 Fan type EC EC Voltage (at operation point)* 1500 Extract Air Maximum air volume @ 200 Pa m /hr / l/sec 3600 / 1000 3600 / 1000 Air volume @ 250 Pa* m3/hr / l/sec 2000 / 556 2000 / 556 C -10 22 O Humidity at inlet* C 18 1 %rh 90 40 %rh 11 Thermal efficiency in winter / summer % Performance in winter / summer kW 19.4 / -2.3 Condensation l/h 6.5 Temperature at inlet* O Temperature at outlet* Humidity at outlet* Type of heat exchanger 100 88 / 84 Counter Flow, Plastic Part No. 90000070 he figures above have been measured at 2000 m /hr and 250 Pa. Please use the Duplexvent Selection * Note: ● TSoftware to calculate measurements at other performance levels. 3 1000 1250 l/sec 500 1000 1500 2000 2500 3000 3500 4000 4500 m3/hr AIR FLOW 750 500 ● ● 0 0 0 Extract Supply 250 500 750 1000 1250 l/sec 500 1000 1500 2000 2500 3000 3500 4000 4500 m3/hr AIR FLOW 100 90 THERMAL EFFICIENCY % Supply Air 750 250 3 3 500 1000 he figures above have been measured at 2000 m /hr and 250 Pa. Please use the Duplexvent Selection * Note: ● TSoftware to calculate measurements at other performance levels. Heat Recovery 250 1250 NOMINAL POWER (W) Ventilation ● 200 ● ● 80 70 60 50 0 0 0 Winter Summer 250 500 750 1000 1250 l/sec 500 1000 1500 2000 2500 3000 3500 4000 4500 m3/hr AIR FLOW + excludes motors. Motor warranty one year from date of purchase. airflow.com Casing Strength Energy Efficiency EN 1886, mm/m 0 D1 4 D2 10 D3 Eurovent A 1 B C D ͚ E CERTIFIED COMPONENT Passive House Institute F e1 - outdoor air (ODA) e2 - supply air (SUP) supply air 400 V 0.45 kW 2000 m /hr 250 Pa 19°C 11% 3 Me.103.EC3 2000 m3/hr 250 Pa 22°C 40% filtration M5 extract air -10°C 90 % i2 400 V 0.45 kW 2000 m /hr 250 Pa 26°C 28% 3 5 e1 filtration F7 -10 °C 90% Me.103.EC3 2000 m3/hr 250 Pa 26°C 50% outdoor air extract air 0 1 2 3 23°C 60% 10 6 e1 outdoor air 90 Supply Air 11 18.0 Exhaust Description t [oC] rh [%] 9 i1 Extract Air 22.0 40 i2 Exhaust Air 1.0 100 10 11 12 13 14 15 x [g/kg of dry air] 30 % 40 % 50 % 60 % 70 % i1 heat recovery 80 % i2 -2.3 kW 90 % 100 % 30 25 20 40 35 h [kJ/kg] 45 50 Supply Description t [oC] rh [%] e1 Outdoor Air 22.0 35 e2 Supply Air 25.0 29 Exhaust Description t [oC] rh [%] 15 10 i1 Extract Air 26.0 50 i2 Exhaust Air 23.0 61 5 0 -10 -15 8 heat recovery e2 2.3 kW e1 -5 Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration. 7 20 % 5 filtration F7 Outdoor Air -10.0 e2 15 5 10 % 30 15 4 0 22°C 35% 50 Description t [oC] rh [%] e1 -5 e1 exhaust air 22°C 35% 45 Supply 5 20 Mi.103.EC3 26°C 50% filtration M5 60 % 0 -10 25 i2 40 35 h [kJ/kg] 30 25 20 i2 10 -15 400 V 0.40 kW 23°C 61% B S4.A.H 84 % -2.3 kW i1 heat recovery 19.4 kW -5 i1 - extract air (ETA) i2 - exhaust air (EHA) 25°C 29% e2 50 % 70 % 80 % 90 % 100 % heat recovery -19.4 kW 10 t [°C] e1 - outdoor air (ODA) e2 - supply air (SUP) supply air 15 1°C 97% Note: AHU functions diagram. Inlet and outlet location may differ from actual position and port configuration. Summer Operation*: 40 % e2 0 22° 40 % i1 exhaust air Mi.103.EC3 S4.A.H 88 % 19.4. kW 30 % i1 20 400 V 0.40 kW 1°C 100 % B 20 % 25 i1 - extract air (ETA) i2 - exhaust air (EHA) 18°C 11 % e2 10 % 30 t [°C] Winter Operation*: -5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 x [g/kg of dry air] Dimensions Front View Right 780 163 163 370x275 780 e2 600 600x300 145 145 140 300 i2 300 75 K K 163 163 Diameter Accessories e1 Outdoor Air 600 x 300 mm e2 Supply Air 600 x 300 mm i1 Extract Air 600 x 300 mm Flexible Connector i2 Exhaust Air 600 x 300 mm Flexible Connector K Condensate Outlet Ø 21 mm Shut-off Damper, Flexible Connector Flexible Connector Condensate Trap 300 Top View Accessories Weight = 320kg 1040 Type 150 K Connections 600 600x300 e1 75 i1 150 150 75 600 75 600x300 1660 600 600x300 145 145 140 1040 140 300 Left 2450 370 x 275 See Duplexvent accessories for more details. * The above figures are example performance measurements. Please use the Duplexvent Selection Software to calculate measurements at other performance levels. Call: 01494 560800 Visit: airflow.com Airflow Developments Limited Aidelle House, Lancaster Road, Cressex Business Park, High Wycombe, Buckinghamshire, United Kingdom, HP12 3QP E-mail: [email protected] Telephone: +44 (0) 1494 525252 airflow.com © Airflow Developments Limited. Airflow Developments Limited reserve the right, in the interests of continuous development, to alter specifications without prior notice. All orders are accepted subject to our conditions of sale which are available on request Certificate No. EMS 569454 Certificate No. FM 00152 BS EN 1SO 14001 : 2004 BS EN 1SO 9001 : 2008