Preview only show first 10 pages with watermark. For full document please download

Dvm2b_nylon

   EMBED


Share

Transcript

Application and Installation Guide Series DVM-2B Nylon Media Separated 2-Way, 2 Position, Normally Open and Normally Closed Solenoid Valves. Two-Way, Two Position, Normally Closed Pressure Outlet A (2) Series DVM-2B Nylon Media Separated 2-Way, 2 Position, Normally Open and Normally Closed Solenoid Valves. Two-Way, Two Position, Normally Closed Position 1) Coil De-energized. Pressure inlet port P (1) is blocked to outlet port A (2). Position 1) Coil De-energized. Pressure inlet port P (1) is blocked to outlet port A (2). Position 2) Coil Energized. Pressure inlet port P (1) is open to port A (2). Position 2) Coil Energized. Pressure inlet port P (1) is open to port A (2). P A   Electrical Hook-Up Pressure Inlet P (1)  Pressure Inlet P (1) Pressure Outlet A (2) P A Electrical Hook-Up Earth Ground 18 mm DIN Power leads connected to vertical pins on all versions. Not Earth Ground polarity sensitive. www.AutomationDirect.com 1-800-633-0405 Application and Installation Guide Series DVM-2B Nylon  Series DVM-2B Nylon 18 mm DIN Power leads connected to vertical pins on all versions. Not polarity sensitive. 3505 Hutchinson Rd., Cumming, GA 30040 DVM2Bnylon Rev.02 www.AutomationDirect.com 1-800-633-0405 3505 Hutchinson Rd., Cumming, GA 30040 DVM2Bnylon Rev.02 Application and Installation Guide Series DVM-2B Nylon Mounting Diagram Application and Installation Guide Series DVM-2B Nylon Mounting Diagram Dimensions Inch [mm] Dimensions Inch [mm] MOUNTING HOLES (2x) 0.094 DIA FOR #4 SELF-TAPPING SCREW 0.860 [21.84] 0.470 [11.94] 0.860 [21.84] 0.470 [11.94] 0.170 [4.32] Caution MOUNTING HOLES (2x) 0.094 DIA FOR #4 SELF-TAPPING SCREW 0.860 [21.84] Caution 0.860 [21.84] 0.170 [4.32] Warranty Information Excessive use of pipe sealant can cause clogging and leakage. Please follow ASME standards for applying pipe sealant and tape. Do not use media, voltage or pressures other than that listed in specifications as valve malfunction could result. Misuse or misapplication of NITRA solenoid valves could cause serious bodily injury or property damage. Excessive use of pipe sealant can cause clogging and leakage. Please follow ASME standards for applying pipe sealant and tape. Do not use media, voltage or pressures other than that listed in specifications as valve malfunction could result. Misuse or misapplication of NITRA solenoid valves could cause serious bodily injury or property damage. www.AutomationDirect.com 1-800-633-0405 www.AutomationDirect.com 1-800-633-0405 3505 Hutchinson Rd., Cumming, GA 30040 3505 Hutchinson Rd., Cumming, GA 30040