Preview only show first 10 pages with watermark. For full document please download

Dvo623 Forward Path Amplifier

   EMBED


Share

Transcript

Product Specification Broadband Cable Networks / Kari Mäki November 6, 2002 DVO623 1(2) DVO623 FORWARD PATH AMPLIFIER for DVO fibre optic CATV link. It is a general purpose wide band amplifier with diplex filter at the output. The out-coming RF-power is measured by the wide band power detector to see the signal status. This product is fully compatible with DVX Head End system and can be installed in a standard DVX001 installation frame. Features • • • • • • • Adjustable input attenuator Adjustable input equaliser GaAs PD output stage Front panel test point Extra signal injection point 3 equal return outputs Remote control of adjustements by using Commander software Technical specifications Parameter Specification (with diplex filters) Note Signal parameters Frequency range Return loss Forward gain Gain control range Nominal slope Slope control range Flatness RF test point Ext. In point Output level, CTB CENELEC Output level, CSO CENELEC Noise figure Return gain Return output level DIN45004B Return noise figure 47…862 MHz 18 dB 24.0 dB 0…- 8 dB 8 dB 0…+5 dB ± 0.5 20 dB -20 dB 112.0 dBµV 113.0 dBµV 10.0 dB 3 x 0 dB 3 x 112.0 dBuV 6.0 dB 1 2 3 4 5 4 6 7 8 9 10 General Power consumption Supply current (24 V) Supply current (12.5 V) Supply current (6.0 V) Connectors Dimensions Weight Operating temperature EMC 14.0 W 370 mA 350 mA 100 mA IEC-female 6U x 7HP x 170 mm 1.3 kg + 5...+ 45 °C EN50083-2 DVO623_spec_v11.doc, created on November 1, 2002, printed on November 6, 2002 Product Specification Broadband Cable Networks / Kari Mäki DVO623 November 6, 2002 2(2) Notes 1) The product is available with different output diplex filters. 2) At 40 MHz, -1.5 dB / octave. Always better than 15 dB. Return path is having a return loss of –20 dB or better. 3) Typical value. Guaranteed gain is at least 23.0 dB. 4) Adjustment with the steps of 0.2 dB. The pivot point for slope adjustment is at 862 MHz. 5) Accuracy is ± 1.0 dB. 6) Accuracy is ± 0.5 dB. 7) The injected signal is having a 20 dB lower output level than the signal fed at the main input. 8) Typically. EN50083-3, CTB at +25°C, 41 channels , sloped response. 9) Typically. EN50083-3, CSO at +25°C, 41 channels., sloped response. 10) Typical value. The maximum value is 1.0 dB worse. The value is measured at the low end of the band. At 862 MHz the value is better. Block diagram EXT. IN TP F OUT R IN dB IN R OUT 1 2 3 CONTROLLER DVX-BUS Ordering information Product Output split Note DVO623 0 dB jumper at output Not available DVO623 30 30/47 MHz Available DVO623 50 50/70 MHz Not available DVO623 65 65/85 MHz Available DVO623_spec_v11.doc, created on November 1, 2002, printed on November 6, 2002