Transcript
DVV 1000D6-8/120°+REV ROOF FA
Document type:
Item no. 3663
Generated by:
Document date:
Product card 2012-07-14 Systemair Online Catalogue
Version: 6-pol Description ● ● ● ● ●
Motor outside of the air stream Max temperature of transported air 120°C Vertical exhaust Suitable for coastal applications Wide range of accessories
The octagonal casing is manufactured from seawater resistant aluminium (4 pole 1000-M and P from aluzinc steel sheet). The base frame consist of galvanised steel. The impeller with backward-curved blades is also manufactured from galvanised steel. The fan is equipped with IEC flange electric motor with degree of mechanical protection IP 54, insulation class F. Single speed resp. two speed motors as Dahlander (4-8, 6-12) or with separate windings (6-8, 4-6, 8-12). Motor cooling with fresh air via air duct. Thermal motor protection on request (PTC or thermal contact). For frequency controlled units PTC must be ordered. For smaller two speed fans (up to 10A) two speed switch is available as accessories (in this case thermal contact must be ordered; not suitable for PTC or without thermal contact). Connection the fan to the mains in service switch (serial at sizes 800 and 1000) on the casing. Other sizes equipped with terminal box, service switch on request. EMC protected cables, cable glands or service switches on request. On request fan can be factory fitted with sound attenuator on outlet as DVVI/120 fan. Sound attenuators are also available as HSDV accessories.
Technical parameters Parameter
Value Unit
Voltage
400
Connection
Y
V
Frequency
50
Hz
Phase
3
~
Power at shaft (P2)
11000
W
Current
22
A
Starting current
154
A
Max. airflow
44800
m³/h
Fan impeller speed
970
r.p.m.
Max. temperature of transported air 120
°C
Sound pressure level at 4 m
74
dB(A)
Sound pressure level at 10 m
66
dB(A)
Weight
400
kg
Insulation class, motor
F
Enclosure class, motor
55
IP
Diagrams
Name: DVV 1000D68/120° REV ROOF FA DVV 1000D68/120° REV ROOF FA DVV 1000D68/120° REV ROOF FA | Item no.: 3663 3663 3663 | Version: 6pol 6pol Document type: Product card Product card Product card | Document date: 20120714 20120714 20120714 | Generated by: Online catalogue Online catalogue
1 / 3
Hydraulic data Q [m³/h]
Pstat [Pa]
P [W]
Working point n I η [r.p.m.] [A] [%]
SFP [kW/m³/s]
U [V]
Acoustics 1000D6
Hz
Tot 63 125 250 500 1k
2k
4k
8k
LwA Inlet
dB(A)
92
69
78
84
88
83
81
79
67
LwA Surroundings dB(A)
94
71
80
86
90
85
83
81
69
Measuring point: qv = 6,94 m³/s, Ps = 650 Pa
Dimensions
DVV 1000/120
□A
□B
□C
ød
ød1
ød2
øds
F
G
H
nxM
1160
1040
1154
710
751
18
710
1500
1350
70
16xM10
Wiring Low speed connection
High speed connection
Name: DVV 1000D68/120° REV ROOF FA DVV 1000D68/120° REV ROOF FA DVV 1000D68/120° REV ROOF FA | Item no.: 3663 3663 3663 | Version: 6pol 6pol Document type: Product card Product card Product card | Document date: 20120714 20120714 20120714 | Generated by: Online catalogue Online catalogue
2 / 3
Accessories Accessories ASFV 1000 flange DVV (3703) ASK/F 1000 inflow box, galv. (305208) ASSV 1000 Flex. conn. DVV (3721) ESDV 1000 inlet cone DVV (31123) FDV 1000 flat roof socket DVV (3691) FDVE 1000 roof socket DVV (3680) HSDV 1000 mounted on DVV (95083) SSV 1000 Socket silencer DVV (4423) SSVE 1000 socket silencer DVV (3774) VKV/F 1000 Autom. shutter DVV (3715) VKVM 1000 motor. shutter DVV (31255)
Specification text Roof fan, vertical blowing. The DVV/120 radial fans are intended for the normal daily ventilation, temperature of air up to 120°C. The base plate and the inlet cone are made of hot-dip galvanized steel sheet. The outer octagonal casing from seawater-resistant aluminium (4 pole 1000M and P from aluzinc steel sheet). Bird protection grill inside casing. The air stream is carried out through annular space between the casing and the motor housing. The fan has an electroplated backward curved radial impeller made of steel sheet, single inlet. With hub and secured bolted joint directly assembled on the motor shaft. Dynamically balanced according to ISO 1940 T1 quality class G6,3. Driven by an IEC standard motor, two-speed (separate winding 4-6 and 6-8, Dahlander 4-8 and 6-12). Cooling of the motor with ambient air through an isolated air duct in underpressure system. The motor protection is provided by customers. PTC or thermal contact built-in electric motor on request. For frequency controlled units PTC must be ordered. For smaller sizes (up to 10A) two speed switch is available as accessories (in this case thermal contact must be ordered; not suitable for PTC or without thermal contact). Connection the fan to the mains in service switch (serial at sizes 800 and 1000) outside on casing. Other sizes equipped with terminal box on the same place, service switch available on request. EMC protection (for frequency control, if needed) on request, serial not EMC protected cables, cable glands and service switches are used. Flange connection according to DIN 24154R3. An additional sound attenuator HSDV/F is available on enquiry.
Name: DVV 1000D68/120° REV ROOF FA DVV 1000D68/120° REV ROOF FA DVV 1000D68/120° REV ROOF FA | Item no.: 3663 3663 3663 | Version: 6pol 6pol Document type: Product card Product card Product card | Document date: 20120714 20120714 20120714 | Generated by: Online catalogue Online catalogue
3 / 3