DX4 Programming (COIN - OPL) Operating instructions This manual concerns firmware version 1.09 Models starting Serial No. 1111000030
Instruction manual
70468201
Part No. 70471401R5EN August 2012
Contents 1 Model numbers.................................................................................................. 5 2 Safety instructions ........................................................................................... 7 3 Connections....................................................................................................... 8 Connection of the central operating panel for coin operated dryers (option).. 8 Connection of the serial communication (option) .......................................... 8 4 Setting mode...................................................................................................... 9 Setting menu ................................................................................................. 9 Scrolling display ............................................................................................. 9 Setting the Entry Code ................................................................................ 11 Dryer with OPL ............................................................................................ 13 Coin-operated dryer ..................................................................................... 21 Reversing Mode ..........................................................................................28 5 Operating instructions ................................................................................... 29 OPL-dryer (if scroll = YES) .......................................................................... 29 OPL-dryer (if scroll = no) ............................................................................. 31 Coin-operated dryer (if scroll = YES) ........................................................... 33 Coin-operated dryer (if scroll = no) .............................................................. 36 6 Technical remarks .......................................................................................... 39 Gas failure .................................................................................................. 39 Electronic temperature protection ................................................................ 39 Sail switch .................................................................................................... 39 Rotation sensor ........................................................................................... 39 7 Repair and after-sales service ...................................................................... 40
© Copyright 2012, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher.
Content
4
1
Model numbers
Gas 25 Pound
30 Pound
Steam/Thermal Oil
Electric
DR25G2-BA025L
DR25G2-BU025L
DR25S2-BT025S
DR25E2-BT025E
DR25G2-BA025N
DR25G2-BU025N
DR25S2-BU025S
DR25E2-BU025E
DR25G2-BT025L
IPD25G2-IT025L
IPD25S2-IT025S
IPD25E2-IT025E
DR25G2-BT025N
IPD25G2-IT025N
DR30G2-BA030L
DR30G2-BU030L
DR30S2-BT030S
DR30E2-BT030E
DR30G2-BA030N
DR30G2-BU030N
DR30S2-BU030S
DR30E2-BU030E
DR30G2-BT030D
IPD30G2-IT030L
IPD30S2-IT030S
IPD30E2-IT030E
DR30G2-BT030L
IPD30G2-IT030N
DR30G2-BT030N
T30 Pound
CHD30STG2-CAT30L
DR335
CHD30STS2-CTT30S
CHD30STE2-CTT30E
CHD30STG2-CAT30N
DR335-BUT30E
CHD30STS2-CUT30S
CHD30STE2-CUT30E
CHD30STG2-CTT30L
DR335-BUT30L
DRST30S2-BTT30S
DRST30E2-BTT30E
CHD30STG2-CTT30N
DR335-BUT30N
DRST30S2-BUT30S
DRST30E2-BUT30E
CHD30STG2-CUT30L
DR335-BUT30S
IPD30STS2-ITT30S
IPD30STE2-ITT30E
CHD30STG2-CUT30N
DRST30G2-BAT30L
IPD30STG2-ITT30L
DRST30G2-BAT30N
IPD30STG2-ITT30N
DRST30G2-BTT30D DRST30G2-BTT30L DRST30G2-BTT30N DRST30G2-BUT30L DRST30G2-BUT30N
35 Pound
T45 Pound
DR35G2-BA035L
DR35G2-BU035L
DR35S2-BT035S
DR35E2-BT035E
DR35G2-BA035N
DR35G2-BU035N
DR35S2-BU035S
DR35E2-BU035E
DR35G2-BT035L
IPD35G2-IT035L
IPD35S2-IT035S
IPD35E2-IT035E
DR35G2-BT035N
IPD35G2-IT035N
CTT45L
DRST45G2-BAT45L
CTT45N
DRST45G2-BAT45N
DR445-BAT45L
DRST45G2-BTT45D
DR445-BAT45N
DRST45G2-BTT45L
DR445-BTT45D
DRST45G2-BTT45N
DR445-BTT45L
DRST45G2-BUT45L
DR445-BTT45N
DRST45G2-BUT45N
DR445-BUT45L
IPD45STG2-ITT45L
DR445-BUT45N
IPD45STG2-ITT45N
Not Applicable
Not Applicable
5
Gas
50 Pound
55 Pound
Steam/Thermal Oil
1
Electric
DR50G2-BA050L
DR55G2-BT050D
DR55S2-BT050S
DR55E2-BT050E
DR50G2-BA050N
DR55G2-BT050L
DR55S2-BT050T
DR55E2-BU050E
DR50G2-BT050D
DR55G2-BT050N
DR55S2-BU050S
DR50E2-BT050E
DR50G2-BT050L
DR55G2-BU050L
DR55S2-BU050T
DR50E2-BU050E
DR50G2-BT050N
DR55G2-BU050N
DR50S2-BT050S
IPD50E2-IT050E
DR50G2-BU050L
IPD50G2-IT050L
DR50S2-BT050T
DR50G2-BU050N
IPD50G2-IT050N
DR50S2-BU050S
DR55G2-BA050L
DR50S2-BU050T
DR55G2-BA050N
IPD50S2-IT050S
DR55SG2-BA055L
DR55SG2-BU055L
DR55SG2-BA055N
DR55SG2-BU055N
DR55SG-BT055D
IPD55G2-IT055L
DR55SG2-BT055L
IPD55G2-IT055N
DR55SE2-BT055E Not Applicable
DR55SE2-BU055E IPD55E2-IT055E
DR55SG2-BT055N
75 Pound
120 Pound
170 Pound
DR75G2-BA075L
DR80G2-BT075D
DR80S2-BT075S
DR80E2-BT075E
DR75G2-BA075N
DR80G2-BT075L
DR80S2-BT075T
DR80E2-BU075E
DR75G2-BT075D
DR80G2-BT075N
DR80S2-BU075S
DR75E2-BT075E
DR75G2-BT075L
DR80G2-BU075L
DR80S2-BU075T
DR75E2-BU075E
DR75G2-BT075N
DR80G2-BU075N
DR75S2-BT075S
IPD75E2-IT075E
DR75G2-BU075L
IPD75G2-IT075L
DR75S2-BT075T
DR75G2-BU075N
IPD75G2-IT075N
DR75S2-BU075S
DR80G2-BA075L
DR75S2-BU075T
DR80G2-BA075N
IPD75S2-IT075S
DR120G2-BA120L
DR120G2-BU120N
DR120S2-BT120S
DR120E2-BT120E
DR120G2-BA120N
DR120G2-BU120L
DR120S2-BT120T
DR120E2-BU120E
DR120G2-BT120L
DR120S2-BU120S
DR120G2-BT120N
DR120S2-BU120T
DR170G2-BA170L
DR170S2-BT170S
DR170G2-BA170N
DR170S2-BT170T
DR170G2-BT170L
DR170S2-BU170S
DR170G2-BT170N
DR170S2-BU170T
Not Applicable
DR170G2-BU170L DR170G2-BU170N
200 Pound
DR200G2-BA200L
IPD200G2-IT200L
DR200S2-BT200S
DR200G2-BA200N
IPD200G2-IT200N
DR200S2-BT200T
DR200G2-BT200L
DR200S2-BU200S
DR200G2-BT200N
DR200S2-BU200T
DR200G2-BU200L
IPD200E2-IT200S
DR200G2-BU200N
IPD200E2-IT200T
Not Applicable
Includes models with the following control suffixes: 3B - reversing DX4 vend
3W - reversing DX4 prep for coin
3O - DX4 OPL
3X - DX4 prep for coin
3V - DX4 vended
R3 - reversing DX4 OPL
6
2
Safety instructions
Ignoring any of the safety instructions can cause serious personal injury and can also cause damage to the linen and the dryer. Carefully read the installation and operating instructions before connecting the machine. It is recommended to have the machine installed by qualified technicians. The installation needs to be executed according to the Installation manual. The grounding instructions must be followed in order to avoid the risk of electrocution. The machine may not be exposed to high humidity, nor to extreme high or low temperatures. The dryer may not be used in a closed-off room with insufficient air supply. If necessary, the doors or windows should be provided with a ventilation grate. Cut off all main gas, steam and electrical supplies at the end of each operating day. Before repairing or maintaining the dryer, wait until the machine is sufficiently cooled down and cut off all supply lines. To prevent fire and explosion : - Keep the area around the dryer free from inflammable or combustible products. - Clean the piled-up dust in and around the dryer and fan regularly. If you detect a gas smell : - Immediately cut off the gas supply and ventilate the room. - Do not switch on electrical appliances and do not switch on any electrical switches. - Don’t ever use matches or lighters. - Don’t ever use a telephone in the same building. - Notify the installer as soon as possible and the gas company, if necessary. Always take into account the instructions on the labels of the linen. Never allow children to play near a machine.
- Do not use the dryer to dry material with a low melting temperature (PVC, rubber, …). - Do not dry any products that still contain solvents or other inflammable substances. Remark: These instructions won’t automatically prevent all risks of accidents. It is up to the user to act with utmost care. Do not hesitate to contact the dealer in case of a problem. 7
3
Connections Connection of the central operating panel for coin operated dryers (option)
The central payment board (209/00471/50 for 24V and 209/00438/50 for 240V) with connectors, to which the central operating panel has to be connected. There are two possible versions as the departure voltage of the operating panel.
OUT OUT
24V
Coin cyclus N
C OUT OUT
24V
240V com 24V
24V
240V
Coin cyclus N
DX4
DX4
CENTRAL PANEL 240V AC CENTRAL PANEL 24VAC
CENTRAL PANEL 24VDC
Connection of the serial communication (option) If the dryer is connected to a payment system with serial communication, this connection should be fixed on this printboard (209/00540/00) by means of a RJ 11. Connect the cable to the free connector on the printboard.
8
4
Setting mode Setting menu
+
Scrolling display
The following buttons have a specific function in the setting menu: - Left button : decreases a value. - Middle button : confirms a value and/or continues. - Right button : increases a value. The setting menu is different for a dryer with or without coin meter.
To turn the scrolling display function on or off, follow these steps: 442394 1. Enter manual programming mode by pressing the middle and right button together. 2. Enter access code (defaults: ABC for coin; 123 for OPL). When powering up the control, note the three digit program number. If your control has program number 2xx, your default password = 123. If your program number is 6xx, your default password = ABC. It is strongly recommended coin store owners change and document your programming password for security reasons. 3. Press the middle button until "SCr" is displayed. 4. Press the middle button. 5. Press the left button until "YES" is displayed. 6. Press the middle button until out of manual programming mode. 7. The display will now scroll.
9
4 +
+
+
+
+
+
+
10
4 Setting the Entry Code Cod (entry code) Simultaneously select the central key and the right key "+". Confirm the adjustment by means of the middle button. When powering up the control, note the three digit program number. If your control has program number 2xx, your default password = 123. If your program number is 6xx, your default password = ABC. It is strongly recommended coin store owners change and document your programming password for security reasons.
Set the code (first display) with the + or – key. (from 0 to 9 and from A to Z, except for Q – S – W – X – Z). Confirm the adjustment by means of the middle button. - Each time these keys are pressed and released, the setting is increased or decreased with ONE unit. By keeping the keys pressed, the value is changed continuously. - These rules apply to all other settings. Set the code (second display) with the + or – key. (from 0 to 9 and from A to Z, except for Q – S – W – X – Z). Confirm the adjustment by means of the middle button.
Set the code (second display) with the + or – key. (from 0 to 9 and from A to Z, except for Q – S – W – X – Z). Confirm the adjustment by means of the middle button. SEt (Modify the entry code) Press the middle button to continue. If so needed, modify the code (first display) with the + or – key (from 0 to 9 and from A to Z, except for Q – S – W – X – Z). Confirm the selection with the central key.
If so needed, modify the code (second numerical code) with the + or – key (from 0 to 9 and from A to Z, except for Q – S – W – X – Z). Confirm the adjustment by means of the middle button.
If so needed, modify the code (third display) with the + or – key (from 0 to 9 and from A to Z, except for Q – S – W – X – Z). Confirm the adjustment by means of the middle button.
Adr (address) When the dryer is connected to a coin system in which the dryers are put in a computer network, enter here the dryer address, in other events, this parameter does not have to be modified.
11
4 M403A2
+
+
+
+
+
+
+
+
+ 12
+
4 Dryer with OPL oPL or Coin (coin-operated dryer) Select oPL with the "+ key" (right key). Confirm the adjustment by means of the middle button. H01 or H02 or H03 (heating class) H01 (25, 30, 35 and 55 pounds) uses internal temperature calibration group 1 + 1 speed detection spoke H02 (50, 75, 120, 170 and 200 pounds) uses internal temperature calibration group 2 + 6 speed detection spokes H03 (T30 and T45 pounds) uses internal temperature calibration group 3 + 1 speed detection spoke Select the heating with the "+ key" (right key). Confirm the adjustment by means of the middle button. rot (rotation sensor) Press the middle button to continue. YES or no With the "+ key" (right key), set Yes or no. Confirm the adjustment by means of the middle button. °C or °F With the "+ key" (right key), select °C or °F. Confirm the adjustment by means of the middle button. rEV (reversing) Press the middle button to continue. YES or no With the "+ key" (right key), set Yes or no. Confirm the adjustment by means of the middle button. TE 1 (Temperature program 1) Press the middle button to continue. If necessary, change this value (default 40°C/104°F) by means of the + or - button between 25°C/77°F and 90°C/194°F. - By pressing and releasing these buttons, the adjustment is increased or decreased with 1 unit. By keeping these buttons pressed, the value is continuously changed. Confirm the adjustment by means of the middle button. Ti 1 (dry cycle program 1) Press the middle button to continue. If necessary, change this value (default 30) by means of the + or - button between 1 and 120 minutes. Confirm the adjustment by means of the middle button. For dryers without reversing, the program goes immediately to "TE2".
13
4
+
+
+
+
+
+
+
+
+
+
+
+
14
4 St 1 (Stop time between left - right movement of the drum) Press the middle button to continue. Change if necessary this value (default 6 seconds) by means of the + or - button between 5 and 10 seconds. Confirm the adjustment by means of the middle button. AC 1 (Action time of the drum) Press the middle button to continue. Change if necessary this value (default 25 seconds) by means of the + or - button between 5 and 120 seconds. Confirm the adjustment by means of the middle button. TE 2 (temperature program 2) Press the middle button to continue. If necessary, change this value (default 60°C/140°F) by means of the + or - button between 25°C/77°F and 90°C/194°F. Press the middle button to continue. Ti 2 (dry cycle program 2) Press the middle button to continue. If necessary, change this value (default 30) by means of the + or - button between 1 and 120 minutes. Confirm the adjustment by means of the middle button.
For dryers without reversing, the program goes immediately to "TE3". St 2 (Stop time between left - right movement of the drum) Press the middle button to continue. Change if necessary this value (default 6 seconds) by means of the + or - button between 5 and 10 seconds. Confirm the adjustment by means of the middle button. AC 2 (Action time of the drum) Press the middle button to continue. Change if necessary this value (default 25 seconds) by means of the + or - button between 5 and 120 seconds. Confirm the adjustment by means of the middle button.
15
4
+
+
+
+
+
+
+
+
+
+
16
4 TE 3 (temperature program 3) Press the middle button to continue. If necessary, change this value (default 80°C/176°F) by means of the + or - button between 25°C/77°F and 90°C/194°F. Confirm the adjustment by means of the middle button. Ti 3 (dry cycle program 3) Press the middle button to continue. If necessary, change this value (default 35 minutes) by means of the + or - button between 1 and 120 minutes. Confirm the adjustment by means of the middle button.
For dryers without reversing, the program goes immediately to "Cd". St 3 (Stop time between left - right movement of the drum) Press the middle button to continue. Change if necessary this value (default 6 seconds) by means of the + or - button between 5 and 10 seconds. Confirm the adjustment by means of the middle button. AC 3 (Action time of the drum) Press the middle button to continue. Change if necessary this value (default 25 seconds) by means of the + or - button between 5 and 120 seconds. Confirm the adjustment by means of the middle button. Cd (Cool down) This is the cool down cycle, which needs to be executed after the dry cycle. Press the middle button to continue. If necessary, change this value (default 2 minutes) by means of the + or - button between 1 and 30 minutes. Confirm the adjustment by means of the middle button.
17
+
4
+
+
+
+
18
4 FLS (Flash: description of the remaining dry time and the dry temperature) Press the middle button to continue. YES or no Select by means of the + button. no: The remaining dry time will appear during operation. YES: Besides the remaining dry time, also the dry temperature is appearing during operation. Confirm the adjustment by means of the middle button. SCr (Scroll text on display) Press the middle button to continue. YES or no Select by means of the + button. no: The text on the display is not scrolling. YES: The text on the display is scrolling. Confirm the adjustment by means of the middle button. TMP (temperature sensor test) Press the middle button to continue. The drum temperature is now appearing as sensor test. Meanwhile, the 3 leds are lighting alternately. Press the middle button to continue. in Here the entries are checked. When coin switch 1 is closed, the displayed value is changed by 2. When coin switch 2 is closed, the displayed value is changed by 4. When the door is opened, the displayed value is changed by 1. If the dryer is equipped with a sensor measuring the drum number of revolutions, the displayed value is changed by 8 if the drum is rotated manually. Press the middle button to continue. Now End is displayed. This is the end of the setting menu. The program automatically returns to the beginning.
19
4 M403A2-CO I N
+
+
+
+
+
+
+
+
+
+
+
+
+
+ 20
+
4 Coin-operated dryer oPL or Coin (coin switch) Select Coi with the ”+” key. Confirm the selection with the central key. FrE (Free Vend - minutes) If set to 0 : normal coin operation: start of dry cycle if coin drop is detected If set to 1-99 : "Free Vend" mode selected : user can start 1 of the 3 dry cycles by pressing the start button, no coins are needed. Cycle is started for 1-99 minutes. If Free Vend is selected, the "coin 1", "coin 2" and "Add" settings are disabled. C1L (Coin 1 Low - minutes) Press the middle button to continue.
This is the drying time in minutes, which will be added each time a coin is inserted in coin 1. Change this value if necessary (default 10 minutes) between 0 and 120 minutes by means of the + or - button. Confirm the setting by means of the middle button. S1L (Coin 1 Low - seconds) Press the middle button to continue.
This is the drying time in seconds, which will be added each time a coin is inserted in coin 1. Change this value if necessary (default 0 seconds) between 0 and 59 seconds by means of the + or - button. Confirm the setting by means of the middle button. Remark If the dryer is connected to a system on which it is possible to determine a different rate according to the period of time (e.g. Sigma explorer), 3 rates (happy hour) can be programmed. (Low, Medium, High). Press the middle button. Then give in the values for C1M and S1M (coin meter 1, middle rate), C1H and S1H (coin meter 1, highest rate), C2L and S2L (coin meter 2, lowest rate), C2M and S2M (coin meter 2, middle rate), C2H and S2H (coin meter 2, highest rate). If the dryer is not connected to a system that can determine different rates, then it is only necessary to put in the value for C1H and C2H (coin 1 and 2 meter, highest rate).
21
+
4
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+ 22
+
4 Add (minimum drying time minutes) Press the middle button to continue. This is the minimum amount of minutes to add before the dryer starts a cycle. Change if necessary this value (default 10 minutes) by means of the + or - button between 0 and 30 minutes. Confirm the adjustment by means of the middle button. Ads (minimum drying time seconds) Press the middle button to continue. This is the minimum amount of seconds to add before the dryer starts a cycle. Change if necessary this value (default 0 seconds) by means of the + or - button between 0 and 59 seconds. Confirm the adjustment by means of the middle button. H01 or H02 or H03 (heating class) H01 (25, 30, 35 and 55 pounds) uses internal temperature calibration group 1 + 1 speed detection spoke H02 (50, 75, 120, 170 and 200 pounds) uses internal temperature calibration group 2 + 6 speed detection spokes H03 (T30 and T45 pounds) uses internal temperature calibration group 3 + 1 speed detection spoke Select the heating with the "+ key" (right key). Confirm the adjustment by means of the middle button. rot (rotation sensor) Press the middle button to continue. YES or no With the "+ key" (right key), set Yes or no. Confirm the adjustment by means of the middle button. °C or °F With the "+key" (right key), select °C or °F. Confirm the adjustment by means of the middle button.
23
+
+
4
+
+
+
+
+
+
+
+
+
+
24
4 TE1 (Temperature program 1) Press the middle button to continue. If necessary, change this value (default 40°C/104°F) by means of the + or - button between 25°C/77°F and 90°C/194°F. - Each time these buttons are pressed and released, the adjustment is being increased or decreased with 1 unit. By keeping these buttons pressed, the value is continuously changed. - These standards prevail for all adjustments, which need to be changed. Confirm the adjustment by means of the middle button. TE 2 (Temperature program 2) Press the middle button to continue. If necessary, change this value (default 60°C/140°F) by means of the + or - button between 25°C/77°F and 90°C/194°F. Confirm the adjustment by means of the middle button. TE 3 (Temperature program 3) Press the middle button to continue. If necessary, change this value (default 80°C/176°F) by means of the + or - button between 25°C/77°F and 90°C/194°F. Confirm the adjustment by means of the middle button. Cd (Cool down) This is the cool down time, which needs to be executed after the drying time. Press the middle button to continue. If necessary, change this value (default 2 minutes) by means of the + or - button between 1 and 30 minutes. Confirm the adjustment by means of the middle button. FLS (Flash: description of the remaining drying time and the dry temperature) Press the middle button to continue. YES or no Select by means of the + button. no: The remaining drying time will appear during operation. YES: Besides the remaining drying time, also the dry temperature is appearing during operation. Confirm the adjustment by means of the middle button.
25
+
4
+
+
+
+
+
26
4 SCr (Scroll text on display) Press the middle button to continue. YES or no Select by means of the + button. no: The text on the display is not scrolling. YES: The text on the display is scrolling. Confirm the adjustment by means of the middle button. rEM (REMOTE START : central coin system) Press the middle button to continue. YES or no Select by means of the + button. : if the dryer is connected to a central operating panel. Otherwise, select no. Confirm the adjustment by means of the middle button. TMP (temperature sensor test) Press the middle button to continue. The drum temperature is appearing now as sensor test. Meanwhile, the 3 leds are lighting alternately. Press the middle button to continue. in Here the entries are checked. When coin switch 1 is closed, the displayed value is changed by 2. When coin switch 2 is closed, the displayed value is changed by 4. When the door is opened, the displayed value is changed by 1. If the dryer is equipped with a sensor measuring the drum number of revolutions, the displayed value is changed by 8 if the drum is rotated manually. Press the middle button to continue. Now End is displayed. This is the end of the setting menu. The program automatically returns to the beginning.
27
4 Reversing Mode Reversing machines are factory built with an auxiliary board in the rear control tray that controls the forward and reverse signals. The board is set to rotate for 25 seconds, pause for six seconds and then rotate in the other direction. To disable the reversing option, unplug the H3 connector on the board for standard forward only direction. Refer to Figure below.
H3 connector
28
5
Operating instructions OPL-dryer (if scroll = YES)
When the dryer is connected to the electric power, 9 horizontal dashes appear for about 5 seconds. Then "PuSH StArt" appears on the display. 44240501
Fill the drum
Open the door and fill the drum. When the door is opened, "CLoSe door" is consecutive on the display. Disentangle the linen as good as possible in order to avoid it from sticking together. Only then, an optimal drying result can be obtained. Overloading the drum can also lead to bad drying results. After having closed the door, "PuSH StArt" is displayed again.
Don’t ever dry fabrics, which can’t resist the dry temperature. Linen, which has been treated with flammable products, needs to be aired first before being put into the drum.
Select and start the drying cycle
Push 1 of the 3 buttons shortly and release it in order to start 1 of the preprogrammed drying programs (see setting menu). Temperature Left button (blue) (40°C - 104°F) Middle button (orange) (60°C - 140°F) Right button (red) (80°C - 176°F)
Drying time Cool down time 30 min. 2 min. 30 min. 2 min. 35 min. 2 min. 44240501
The led, next to the selected push button, is lighting up constantly during the cycle, to show the selected program. 29
44240501 44240501
5 Program development
Display information : A drying cycle consists of “drying time + cool down time” (30 + 2 = 32 minutes). When the cycle is started, the remaining drying time (here consecutive 29' 59 37o) is displayed. The cool down time isn’t taken into account. When “YES” is chosen in the setting menu under “FLS”, then the drying time and the temperature are displayed. When the temperature is indicated with degrees C, then the symbol (°) is displayed. When the temperature is indicated for values, less than 100°F, then this symbol “°” is displayed. When the heating is activated, then the decimal point lights up. Change the remaining drying time The remaining drying time can be reduced or extended by means of the left or the right button. If the drying time is reduced to “0”, then the cool down time starts.
Temporary interruption of the remaining drying time By opening the door, the cycle can be interrupted temporarily in order to reload or to check the drying level. All functions stop, "CLoSE door" is consecutive on the 44240501 is blinking. However, the drying time keeps on display and the led of the button 44240501 counting down. As soon as the door is closed, the cycle needs to be started again. Early termination of the drying cycle By pressing the middle button and releasing it again, the drying cycle is terminated. "End" is displayed until the door is opened. End of the drying time : change to cool down time
44240501
When the drying time has come to an end (here 30 minutes), the cool down time is automatically started (here 2 minutes). This cool down time is completely separated from the drying time. The remaining cool down time is displayed consecutive with "CooL 0’47 31o". Remark : The cool down temperature isn’t displayed. When the cool down period has started, the remaining time can’t be changed anymore. End of the drying cycle
44240501
When the cool down time has come to an end, then the cycle is automatically terminated (here after 30 + 2 = 32 minutes). "End" is displayed until the door is opened.
44240501
44240501
30
5 OPL-dryer (if scroll = no)
When the dryer is connected to the electric power, 9 horizontal dashes 44240501appear for about 5 seconds. Then “O” appears on the display.
Fill the drum
Open the door and fill the drum. When the door is opened, “Dr” is blinking on the display. Disentangle the linen as good as possible in order to avoid it from sticking together. Only then, an optimal drying result can be obtained. Overloading the drum can also lead to bad drying results. After having closed the door, “O” is displayed again.
Don’t ever dry fabrics, which can’t resist the dry temperature. Linen, which has been treated with flammable products, needs to be aired first before being put into the drum.
Select and start the drying cycle
Push 1 of the 3 buttons shortly and release it in order to start 1 of the preprogrammed drying programs (see setting menu). Temperature Left button (blue) (40°C - 104°F) Middle button (orange) (60°C - 140°F) Right button (red) (80°C - 176°F)
Drying time Cool down time 30 min. 2 min. 30 min. 2 min. 35 min. 2 min.
The led, next to the selected push button, is lighting up constantly during the cycle, 44240501 to show the selected program.
31 44240501
44240501
5 Program development
Display information : A drying cycle consists of “drying time + cool down time” (30 + 2 = 32 minutes). When the cycle is started, the remaining drying time (here 30) is displayed. The cool down time isn’t taken into account. When “YES” is chosen in the setting menu under “FLS”, then the dry time and the temperature are displayed alternately. When the temperature is indicated with degrees C, then the symbol (°) is displayed. When the temperature is indicated for values, less than 100°F, then this symbol “°” is displayed. When the heating is activated, then the decimal point lights up. Change the remaining drying time The remaining drying time can be reduced or extended by means of the left or the right button. If the drying time is reduced to “0”, then the cool down time starts.
Temporary interruption of the remaining drying time By opening the door, the cycle can be interrupted temporarily in order to reload or to check the drying level. All functions stop, “Dr” is blinking on the display and the led of the button is also blinking. 44240501 However, the drying time keeps on counting down. As soon as the door is closed, the cycle needs to be started again. 44240501 Early termination of the drying cycle By pressing the middle button and releasing it again, the drying cycle is terminated. “End” is displayed until the door is opened. End of the drying time : change to cool down time
44240501
When the drying time has come to an end (here 30 minutes), the cool down time is automatically started (here 2 minutes). This cool down time is completely separated from the drying time. The remaining cool down time is displayed alternately with “Cd”. Remark : The cool down temperature isn’t displayed. When the cool down period is started, the remaining time can’t be changed anymore. End of the drying cycle
44240501
When the cool down time has come to an end, then the cycle is automatically terminated. (here after 30 + 2 = 32 minutes) “End” is displayed until the door is opened. 44240501
44240501
32
5 Coin-operated dryer (if scroll = YES)
70462601
70462601
When the dryer is connected to the electric power, 9 horizontal dashes appear for about 5 seconds. Then "PAY" appears on the display. If Free Vend is selected, "PuSH StArt" appears on the display.
Fill the drum
Open the door and fill the drum. When the door is opened, "CLoSE door" is consecutive on the display. Disentangle the linen as good as possible in order to avoid it from sticking together. Only then, an optimal drying result can be obtained. Overloading the drum can also lead to bad drying results. After having closed the door, "PAY" is displayed again.
Don’t ever dry fabrics, which can’t resist the dry temperature. Linen, which has been treated with flammable products, needs to be aired first before being put into the drum. 33
5 Coin insertion For each coin insertion in the coin meter, the time value (see setting menu Co 1 and Co 2) is added on the display. As long as the value of parameter "Add" (see setting menu) hasn’t been obtained, "Add 5’ 00" is displayed and the user needs to insert more coins.
When sufficient coins have been inserted, the cycle time and "StA 15' 00" are displayed. The 3 leds, next to the push buttons, are blinking.
Select and start the drying cycle
Push 1 of the 3 buttons shortly and release it in order to start 1 of the pre programmed drying programs (see setting menu). Temperature Left button (blue) (40°C - 104°F) Middle button (orange) (60°C - 140°F) Right button (red) (80°C - 176°F)
Cool down time 2 min. 2 min. 2 min.
The led, next to the selected push button, keeps on blinking for about 10 seconds. 44240501 During this time, the program can still be changed. Afterwards, the led keeps on lighting up constantly.
44240501
34
5 Program development
Display information: When the cycle is started, the remaining drying time (here consecutive 48o 14' 39 ) is displayed. For a coin-operated dryer, the cool down time is included in the drying time. A drying cycle of 30 minutes consists of a drying time of 28 minutes + 2 minutes of cool down time. When “YES” is chosen in the setting menu under “FLS”, then the drying time and the temperature are displayed. When the temperature is indicated with degrees "°C", then the symbol (°) is displayed. When the temperature is indicated for values, less than 100°F, then this symbol “°” is displayed. When the heating is activated, the decimal point lights up.
Temporary interruption or change of the drying cycle. By opening the door, the cycle can be interrupted temporarily in order to reload, to check the drying level or to change the cycle. All functions stop, "CLoSe door" appears on the display. However, the drying time keeps on counting down. As soon as the door is closed, "StA 15' 00" and the remaining cycle time are displayed, all leds next to the push buttons are blinking. Now the cycle, or, if necessary another cycle, needs to be started again.
44240501
End of the drying time : change to cool down time. When the drying time has come to an end (here 28 minutes), the 44240501 cool down time is automatically started (here 2 minutes). The user will not be informed of the start of the cool down period. Remark : When a coin is inserted in the coin meter during the cycle (also during the cool down period or when the door is opened), then this time will be added to44240501 the remaining cycle time. End of the drying cycle. When the cool down time has come to an end, then the cycle is automatically terminated (here 28 + 2 = 30 minutes). "End" is displayed until the door is opened.
35
5 Coin-operated dryer (if scroll = no)
70462601
70462601
When the dryer is connected to the electric power, 9 horizontal dashes appear for about 5 seconds. Then “PAY” appears on the display. If Free Vend is selected, "0" appears on the display.
Fill the drum
Open the door and fill the drum. When the door is opened, “Dr” is blinking on the display. Disentangle the linen as good as possible in order to avoid it from sticking together. Only then, an optimal drying result can be obtained. Overloading the drum can also lead to bad drying results. After having closed the door, “PAY” is displayed again.
Don’t ever dry fabrics, which can’t resist the dry temperature. Linen, which has been treated with flammable products, needs to be aired first before being put into the drum.
36
5 Coin insertion For each coin insertion in the coin meter, the time value (see setting menu Co 1 and Co 2) is added on the display. As long as the value of parameter “Add” (see setting menu) hasn’t been obtained, “Add” is displayed and the user needs to insert more coins.
When sufficient coins have been inserted, the cycle time and “StA” are displayed alternately. The 3 leds, next to the push buttons, are blinking.
Select and start the drying cycle
Push 1 of the 3 buttons shortly and release it in order to start 1 of the preprogrammed drying programs (see setting menu). Temperature Cool down time Left button (blue) (40°C - 104°F) 2 min. Middle button (orange) (60°C - 140°F) 2 min. Right button (red) (80°C - 176°F) 2 min. The led, next to the selected push button, keeps on blinking for about 10 seconds. During this time, the program can still be changed. Afterwards, the led keeps on 44240501 lighting up constantly.
44240501
37
5 Program development
Display information: When the cycle is started, the remaining drying time (here 30) is displayed. For a coin-operated dryer, the cool down time is included in the drying time. A drying cycle of 30 minutes consists of a drying time of 28 minutes + 2 minutes of cool down time. When “YES” is chosen in the setting menu under “FLS”, then the drying time and the temperature are displayed alternately. When the temperature is indicated with degrees "°C", then the symbol (°) is displayed. When the temperature is indicated for values, less than 100°F, then this symbol “°” is displayed. When the heating is activated, the decimal point lights up. Temporary interruption or change of the drying cycle. By opening the door, the cycle can be interrupted temporarily in order to reload, to check the drying level or to change the cycle. All functions stop, “Dr” is blinking on the display. However, the drying time keeps on counting down. As soon as the door is closed, “StA” and the remaining cycle time are displayed alternately, all leds next to the push buttons are blinking. Now the cycle, or, if necessary another cycle, needs to be started again.
44240501
End of the drying time : change to cool down time. When the drying time has come to an end (here 28 minutes), the 44240501 cool down time is automatically started (here 2 minutes). The user will not be informed of the start of the cool down period. Remark : When a coin is inserted in the coin meter during the cycle (also during the cool down period or when the door is opened), then this time will be added to44240501 the remaining cycle time. End of the drying cycle. When the cool down time has come to an end, then the cycle is automatically terminated (here 28 + 2 = 30 minutes). “End” is displayed until the door is opened.
38
6
Technical remarks Gas failure
Electronic temperature protection
The electronic ignition of a gas-heated dryer will only try to function once for about 10 seconds. If this fails and the detection device doesn’t detect any flame (for example in case of a gas failure), then the ignition relay goes into safety. When the drying cycle restarts, then a new ignition will occur.
When a temperature of 4°C or less, or of 100°C or more has been detected, the electronic temperature protection will be activated. During operation : Temperature higher than 100°C : The heating is interrupted, but the cycle is completely finished. "ESH" appears on the display.
Temperature lower than 4°C : When after 3 minutes a temperature lower than 4°C is detected, the heating will be interrupted. The cycle is completely finished and "EOP" appears on the display.
Sail switch
The sail switch is in the back and is a protection, which interrupts the heating, in case there is insufficient air supply. This can be the result of an inadequate exhaust, or a dirty filter. 44240501
It is necessary that the sail switch can move freely. In case of a malfunction, "VEn" is blinking on the display and the cycle continues without activating the heating.
44240501
Rotation sensor
In case the drum no longer rotates due to failure (for instance breakdown of a V-belt),"rot" will blink on the display if the machine is equipped with a rotation sensor (option) and the cycle continues without activating the heating. The rotation sensor is fixed at the back of the dryer near the drum axle. 39
7
Repair and after-sales service
In case of important malfunctions and deficiencies, which you can’t resolve yourself, don’t hesitate to contact the technical service department of your distributor.
Data distributor : Name : .................................................................................. Address : ............................................................................... Tel.:.........................................................................................
Data dryer : Type:....................................................................................... Date of installation : ............................................................... Installed by: ........................................................................... Serial number :....................................................................... Operation voltage and frequency : ........................................ Remarks : ..............................................................................
The manufacturer reserves the right to change the contents of this instruction manual at all times and without previous notice.
Alliance Laundry Systems Shephard Street, PO BOX 990 Ripon, WI 54971-0990 United States Tel: 001 920 748 3121 - Fax: 001 920 748 1645 www.comlaundry.com
Alliance International bvba Nieuwstraat 146 - B-8560 Wevelgem (Belgium) Tel. +32 56 41 20 54 - Fax +32 56 41 86 74
[email protected] - www.alliancels.eu
40
41
42