Transcript
Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email:
[email protected] The customer support section of our website also features a wide range of information which may be of use to you and is available 24 hours a day. It includes: • Operating and installation instructions • Easy ‘How to use’ guides for storage heaters • Service and repairs • Where to buy our products • Literature downloads • Heating requirement calculator Visit ‐ www.dimplex.co.uk/support A division of GDC Group Ltd Millbrook House Grange Drive Hedge End Southampton SO30 2DF www.dimplex.co.uk
Registered No: 1313016 England VAT GB 287 1315 50004 EEE Producer Registration Number – WEE/GE0057TS Paper from sustainable sources
Please read this instruction manual carefully before operating your appliance and keep it in a safe place for future reference.
Specifications ~ Automatic defrosting incorporated. Suitable for use in ambient temperatures o
o
6from 5 C~35 C.
o
~ Dehumidification capacity: 10 litres per day at 30 C, 80% R.H. ~ Supply: 220~240V, 50Hz ~ Power consumption: 195W ~ Auto pause when water tank is full ~ Net weight: 10.5 kg ~ Dimensions (mm): 323H x530W x175D ~ Refrigerant: R134a
Key Features ~ Suitable for hanging on a wall, free standing on a table or window sill. ~ Can be directed to help dry items, such as wet laundry. ~ Besides the nylon filter, an activated charcoal filter can be used for removing r dust, smoke and unpleasant odours ~ Automatic controls with 8 hours timer or continuous operation. ~ Automatic defrost function.
Important Safety Information ~ Read All Instructions Carefully Before Using. ~ Use this appliance only for its intended purpose as described in this manual. ~ This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. ~ Children should be supervised to ensure that they do not play with the appliance. ~ This appliance must be properly installed and located in accordance with the location Instructions before it is used. ~ Do not attempt to stand or sit on the appliance. Doing so may result in bodily injury or damage to the product. ~ Do not allow children to play with this appliance or tamper with the controls. ~ Keep fingers out of pinch point areas. ~ Unplug the appliance before cleaning and making repairs. ~ Note: All servicing of the appliance must be performed by properly qualified service personnel. ~ Never unplug your appliance by pulling on the power cord. Always grip the plug firmly and pull straight out from the outlet. ~ When moving the appliance be careful not to roll over or damage the power cord. ~ Warning! This appliance must be earthed. ~ Please refer to the rating plate on the product for the correct voltage, wattage and frequency. ~ The power cord of this appliance is equipped with an earthing plug which mates with a standard earthed wall outlet to minimise the possibility of electric hazard from this appliance. ~ Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly earthed. ~ This appliance is fitted with a special mains lead. Should it need replacing at any time please contact a qualified technician.
Wall mounting your appliance: This dehumidifier can be hung on a wall or used freestanding on a flat level surface. It is suggested to hang it on the wall with more than 150cm above ground, so that infants won't play with it. Place the dehumidifier in a location that does not restrict air flow into the air inlet or out of the air outlet. Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier. The dehumidifier must be operated in an enclosed space to be most effective. Close all doors, windows to the room for effective operation.
Identification of Parts
Wall-mounting instruction: A wall mounting bracket is supplied on the back of the heater for installation.
Set the wall plate against the wall so that the unit will have a floor clearance of at least 150cm. Ensure it is horizontal and mark the 2 fixing locations through the keyhole slots on the plate. Remove plate and drill 2 x 6mm diameter holes 20mm deep and fit the wall plugs supplied, realign the plate and fit the 2 screws supplied tightly in position. Note that 4 additional holes are provided and one or all can be used to permanently fix with steel nails. The appliance is now simply hung onto the bracket by aligning the back panel location to the wall plate and dropping the product onto the plate while pushing it against the wall to ensure it locates properly.
Freestanding Operation The unit must be placed on a stable, level and horizontal surface , otherwise water may leak out when operating. NOTE: When in use you must ensure that the air inlet and air outlet of the appliance are not obstructed
Fitting the Water Tank: The water tank must be fitted properly. When the tank is full or is not in place correctly the" FULL" indication lights and the unit stops or won’t start operating.
NORMAL OPERATION Controls are located at the bottom right hand corner of the appliance. On the left are indicator lights and on the right is a dual option simple rotary control knob for selecting the operation required.
Indicators
Timer control
Timer Control Options: 1) Turn the control knob counter-clockwise to " CONT " for continuous dehumidifying. Alternatively set to " OFF " and the unit turns off. 2) Turn clockwise to select and set the runback time to automatic shut off. " 1 " stands for one hour and " 8 " for eight hours. (Set to " 0 " the unit turns off). Indicators: 1) "DEHUMIDIFY " indicator : it lights up to indicate the unit running dehumidification. 2) "DEFROST " indicator : blinks when defrosting. It will automatically return to dehumidification. (To maintain the efficiency of dehumidification, the defrosting time is controlled to be less than one third of the running time.) 3) " FULL" indicator : This lights up when the water tank is full of water or out of position. To restart please empty the tank and / or refit the tank correctly. Note:
o
o
This appliance can be used in ambient temperatures between 5 C and 35 C. o
Do not operate the unit in temperatures below 5 C, this could cause ice to accumulate in the unit.
To Empty the Water Tank: When the tank is full the " FULL " indicator lights and the unit stops automatically. Wait a few minutes as the appliance is still working or just stopping otherwise some water may spill or drip out. To remove the tank, pull the lower handle gently, carefully support the tank upright and horizontally with two hands and remove to empty. After pouring out the water, clean the tank and replace it on the appliance.
Direct Draining Of Water Water can be automatically emptied from the appliance directly to a drain by attaching a length of thin-wall rubber or plastic tubing with an inside diameter of 6 mm (1/4 inch). Use a screwdriver to remove the knock-out at the back. Attach the tubing to the connector through the hole. The tubing should run to the drain with no sharp bends.
Activated Charcoal Filter
NOTE: Don’t leave a dirty charcoal filter in the unit or malfunction may occur.
Normal Maintenance
See next page for details on where you can obtain replacement filters.
Replacement Filters: Spare filters can be purchased from Dimplex by contacting Tel: 0845 604 2330 (after sales), alternatively spare filters may be available from the retailer / supplier where you bought your appliance.
General cleaning of the appliance: Clean the air inlet and outlet regularly with a soft damp (not wet) cloth as these areas accumulate dust normally. Do not use petrol or solvents or caustic or abrasive cleaning agents.
Before Storing: - Disconnect and wind the power cord up and fit into the cord storage cabinet at the back of the appliance. - Clean the filter. - Empty, clean and dry the water tank. - Cover the unit to prevent it from gathering dust. - Store in a cool and dry place.
TROUBLESHOOTING ADVICE Notes 1) When the appliance is first plugged in and switched on only the Fan will be running, this is normal and continues for about 3 minutes before it will automatically switch to DEHUMIDIFY operation.(This is a design feature to improve the reliability of the product.) 2) When the appliance is operating the surrounding air becomes slightly warmer due to the heating effect of the dehumidifying unit, this is normal and helps to further reduce the relative humidity of the surrounding air. 3) Before you call for service please check the following typical problem list for a cause and solution: PROBLEM Dehumidifier won’t start
POSSIBLE CAUSES The unit is unplugged The fuse is blown or circuit breaker is tripped
The water tank is full or not located correctly No water or just a little water is generated
The control may not be set correctly (timer setting is reached) Airflow is restricted
The filter is dirty Room temperature or humidity is too low Water is produced but humidity does not seem to be reducing.
Noise occurs
Water on floor
Doors and windows are open Steam is being generated in the room Area to be dehumidified is too large for the unit. The unit is not located securely The filter is dirty. The unit is not located correctly The drainage is blocked
WHAT TO DO Make sure the plug is correctly fitted to the outlet Check the house fuse/ circuit breaker box and replace fuse or reset the breaker Empty the tank. Check tank is fitted correctly. Select high hours to run or ‘CONT’ continuous setting operation Make sure there is nothing blocking the air inlet and air outlet. Clean and replace the filter (see page 7) This is normal. Defrosting will take place when temperature is low. Close all doors and windows to control local environment Moisture laden air should be vented to outside the room. Check if the unit capacity is adequate. Relocate the unit or tighten the wall fixings. Clean and replace the filter. Relocate the unit , check wall mounting is level. Clean and repair it (page 6)
Should there still be a problem, please unplug the unit and contact your supplier.