Transcript
Features BNC Input (Video Over Coaxial cable) only • 4ch/8ch/16ch Stand-alone HD Display Real time DVRs (1080p) • Camera menu control through Up-The-Coax.(UTC) communication.
BNC/UTP Input (Video Over Cat.5e Unshield Twist Pair cable) • 4ch/8ch Stand-alone AHD2.0 FHD DVRs (1080p) • 4ch DVR : 4 BNC inputs and 4 UTP inputs 8ch DVR : 8 BNC inputs and 8 UTP inputs • Each UTP input delivers FHD video and Power from/to camera via UTP cable up to 200M. It provides simple and cost saving installation with Cat.5e cable and just plug-and-play. (No coax. cable and No extra power cabling /adapter) • 4 BNC inputs can be used for Non-UTP camera such like PTZ dome. • Optional AHD2,0 Differential converter(a dongle) enables Non-UTP camera to deliver FHD video through UTP cable.
Specifications ITEM Video Input
UTP type BNC type
Video Output Monitor
4CH
Quick Guide
Adaptor & Power cable
Display
8ch UTP
4ch UTP
16CH 16ch BNC 1ch HD OUTPUT, 1ch VGA
UTP type: Up to 200m / BNC type: Up to 500m Quadplex
NTSC PAL
H.264 1920x1080, 1024x768, 1280x720, 1280x1024, 1440x900 1,2,3,4,5,6,7,10,15,30 (NTSC,10 Steps) / 1,2,3,4,5,6,7,9,12,25 (PAL,10 Steps) 120fps @720p/960H/D1
240fps @720p/960H/D1
480fps @720p/960H/D1 240fps @1080p
120fps @1080p
60fps @1080p
NTSC
400fps @720p/960H/D1
200fps @720p/960H/D1
100fps @720p/960H/D1
100fps @1080p
200fps @1080p
Schedule, Manual, Continuous, Continuous+Event
Max. Speed
Common Features
Instruction CD
OPTION
Rack mounting screw (6pcs)
(8ch/16ch: 8pcs)
8CH 8ch BNC
4ch BNC
1ch HD OUTPUT, 1ch Spot (Multi channel), 1ch VGA
Transmission Distance Multitasking Video Compression Resolution No. of Frame
4 Levels (Low, Medium, High, Super)
Quality Recording
Max. Speed (720p/ 1080p)
50fps @1080p
PAL
Mode
Resolution
• AHD2,0(1080p FHD), AHD1.0(720p HD) and Analog(960H) cameras can be used with any combination. • Live video/Play back/Back up of Remote DVR can be accessed by DIRECT VIEW function at DVR or Optional Optimized Remote Video Monitoring Unit(VMU) via network. (Up to 16ch) • Mac Windows 100% compatible CMS. • Free Mobile Viewers(Mobile phones and Tablets)support for iOS and Android.
Composition
120fps (NTSC) 100fps (PAL)
240fps (NTSC) 200fps (PAL)
480fps (NTSC) 400fps (PAL)
Up to HD 1080p x1,x2,x4,x8,x16,x32,x64,x128,x256, Field by Field (Forward,Backward) x1/4, x1/2 Slow Motion (Forward Only), Repeat A-B
Speed
Playback
Quick, Calendar, Bookmark, Event (Sensor, Motion Detection), USB
Mode
Search
Multi Screen
1, 4ch
1, 4, 9ch Optional
Alarm(Relay) Output
Optional
Sensor Input No. of Input
Audio
1, 4, 9, 16ch
1ch
No. of Output
1ch
PTZ Interface
RS-485 Interface
Speed
Network
10/100Base-T (Static, DHCP, E-mail ), DDNS server available
Codec
Dual Codec. (H.264)
Bandwidth Limit
DVR Set
Yes
Motion Detection Storage
22x15 (NTSC) / 22x18 (PAL), 8Level Sensitivity 1 SATA (4TB)
No.of HDD(SATA)
Backup
Mouse
HDD mounting screws
Rack mount bracket (2pcs) (4ch: 4pcs)
2 SATA (4TB per each HDD) HDD, USB Flash Memory, Network
Password Protection Interface PTZ Control
101 Level (admin / 100 users) RS-485
SW Upgrade Method Blackout Protection UTP type
USB Flash Memory, Network Yes 48VDC/ 2A
Power
Consumption BNC type Dimension (mm)
48VDC/ 2A
12VDC/ 3A
-
12VDC/ 3.5A
12VDC/ 3.5A
340W) x 60(H) x 280(L)
Operating Temperature
+5°C ~ +40°C
(*) Design and specifications are subject to change for product improvements without prior notice.
RME1000-V2
- Bad Heat Sinking Before installing and using this product, please read the instruction fully and keep it handy for later use. over 10M - Good Heat Sinking 10cm
◄ Minimum Distance between UTP DVR and UTP Cameras ►
◄ Where/How to place the power adaptors ►
[CAUTION] • Pay attention to safety when laying the connection cable and observe that the cable is not subjected to heavy loads, kinks or damage and no moisture can get in. • The warranty becomes void if repairs are undertaken by unauthorized persons. • Maintenance and repair have to be carried out only by authorized service centers.
Real time Recording & Full HD AHD2.0 DVR 1080P
• Avoid installing areas where has shock or vibration which results in the problems. Caution : Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Mains power quality should be that of a typical commercial environment. If the user of the model requires continued operation during power mains interruptions, it is recommended that the model be powered from an uninterruptible power supply (UPS) or a battery. Warning : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The symbol is intended to alert the user to the presence of important operating and maintenance(servicing) instructions in the literature accompanying the unit.
CAUTION: TO REDUCE THE RISK OF ELECTIRC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The symbol is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
To prevent fire or shock hazard, do not expose the unit to rain or moisture. To prevent electric shocks and risk of fire hazards, do NOT use other than specific power source.
QUICK GUIDE Preliminary
Safety Precaution
Name and Function of Each Part 1. FRONT PANEL
Network Setup 1. NETWORK MONITORING (CMS)
⑤⑥ ⑦
Network monitoring program is provided. It supports Windows PC and Mac PC.
► SYSTEM Requirements Item
①
②
① ② ③ ④
Name Window Display USB port Function button 5 Commands buttons
⑤ ⑥ ⑦
LED LED LED
③
Enter the main menu setting Move the cursor Up/Down, Left/Right Select (Set ) mode in the menu Power Recording Event
①
DC48V
③
②
4
2
⑤
④
⑥
1GB
2GB
Video Memory
128MB
256MB
Hard disk
120GB or higher
OS
Windows XP SP3 or higher
120GB or higher Mac OS X 10.6 or higher
DirectX Version
9.0 or higher
9.0 or higher
1) Open the CMS program 2) Click the mouse right button as below and select ‘Add DVR’ 3) After clicking the Add DVR, enter the information of DVR which you want to Add. Input the name in the name field and input the DDNS address in the Address field. MAC address based default address(ex. 010000.eznetdns.com) and user-defined address(ex.home.eznetdns. com) are both possible. The default ID/PW are admin/1234. Press OK button, the DVR will be added on the list.
VGA
HD VIDEO OUT
Main Memory
Double click the CMS_VerX.X.X_Setup.exe file in the provided CD or downloaded. CMS icon will be created on your desktop.
2-1. UTP 4CH
POWER
Intel Core 2 Duo / 2.2GHz
► Installation and Connection
2. REAR PANEL
1
Mac Book
Intel Pentium 4 / 3.0GHz
Display Resolution 1280 x 1024 (with 32bit color) or higher 1280 x 800 (with 32bit color) or higher
④
Function Built-in Staus LEDs, IR Receiver for remote control (option) USB port
3
Windows PC
CPU
⑦
ETHERNET
⑧
RS485
⑨ ⑩
⑪
2-2. UTP 8CH
POWER
DC48V VGA
HD VIDEO OUT
①
③
②
① ② ③ ④
Name Power DC48V UTP Connector Video In
⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪
HDMI Audio VGA Ethernet USB RS485 Alarm port
⑤
④
⑥
⑦
ETHERNET
⑧
RS485
⑨ ⑩
⑪
Function Power On/Off switch DC Power input connector (Adaptor) UTP Connector Camera Video Input
4) Select the ‘Connection’ by clicking the mouse right button on DVR list you added or doble-click the DVR name. The DVR will be connected.
HD Output port Audio Input, Output VGA Output port Ethernet Connector USB port RS485 communication connector Sensor Input, Relay Output (Option)
5) If you to edit the DVR name or DVR Group, click the ‘Edit DVR’ on menu bar as below.
2-3. BNC 4CH
3
1
4
2
VGA
HD VIDEO OUT
①
②
ETHERNET
RS485
2. MOBILE DEVICE MONITORING ③
④
⑤
⑥ ⑦ ⑧
⑨
2-4. BNC 8CH
► Install and run the application.
VGA
HD VIDEO OUT
①
②
③
④
ETHERNET
⑤
RS485
⑥ ⑦ ⑧
⑨
VGA
HD VIDEO OUT
①
⑤ ⑥ ⑦ ⑧ ⑨
1) Add : After clicking the Add button, enter the information of DVR which you want to Add. Enter a name in the DVR name and a DDNS address in the Address field. MAC address based default address(ex.010000.eznetdns. com) and user-defined address(ex. home.eznetdns.com) are both possible. Input port number in the port field. The default ID/PW are admin/1234. Press OK button, the DVR will be added on the list. 2) Edit : Press the Edit button to edit the information of the selected DVR.
2-5. BNC 16CH
① ② ③ ④
Provide Real-time video monitoring, recorded video search function using a smart phone. Android App: Search ‘ronix’ or ‘rview’ and install the application ‘RVIEW’ iPhone / iPad App: Search ‘rview’ and install the application ‘RVIEW’
Name Video In HDMI Audio VGA Ethernet USB RS485 DC Power jack Alarm port
②
③
④
Function Camera Video Input HD Output port Audio Input, Output VGA Output port Ethernet Connector USB port RS485 communication connector DC Power input connector (Adaptor) Sensor Input, Relay Output (Option)
ETHERNET
⑤
3) Delete/Exit : Press the Delete/Exit button to delete or exit the App. If selects ‘Delete’ menu, confirmation message will pop up for deletion the selected DVR on the list.
RS485
⑥ ⑦ ⑧
⑨ • After selecting the DVR from the list, press the Connection button, then DVR will be connected. • Multi channel Live monitoring , PTZ control, Search and Multi channel playback(Audio support), Remote relay control, Selecting the stream type can be possible.