Preview only show first 10 pages with watermark. For full document please download

E103 - Rooftop Layout - Housing Services Corporation

   EMBED


Share

Transcript

NEW FIXTURE SCHEDULE LIGHTING ON RANGE HOOD TO BE RELAMPED WITH SYLVANIA LED8-DIM-F-830 (TYPICAL OF 1) 5 OS-3 D1 D1 A4 A1 V1 OS-3 D1 4CWPLD4040C 45 29 G, AA LAUNDRY, OFFICE A2 EATON FMLED20WH840PR 32 177 H CORRIDOR AND MAIN ENTRY A3 EATON 8TSNLED-LD4-74SL-UNV-L840-CD1-U 57 10 DB STORAGE ROOMS A4 EATON 4SNLED-LD4-46SL-UNV-L840-CD1-U 41 33 DA MOVE IN, ELECTRICAL, PENTHOUSE MECHANICAL ROOMS A5 EATON 4SNLED-LD4-46SL-UNV-L840-LB-ERMS360-CD1-U 41 4 N/A N/A A6 BEGHELLI BX910LED-4HT-50W-WT40-120-277V 50 25 AA OUTDOOR STAIRWELL BB EATON 4SLSTP4040DD-UNV (x2) WITH WIRE GUARD 43 (2) 67 (2) BB UNDERGROUND PARKING BA EATON 4SLSTP4040DD-UNV (x2) WITH WIRE GUARD 43 (2) 18 (2) BA UNDERGROUND PARKING K1 EATON 4SWLED-LD4-44HL-UNV-L840-CD-1-U 43.3 54 AA INDOOR STAIRWELL D1 EATON SLD612840WH 14.8 35 J, H COMMON ROOM, EXTERIOR ARCH LIGHTING P1 EATON PRV-A15-D-UNV-T2-BZ 87 1 N EXTERIOR SITE LIGHTING P2 EATON PRV-A15-D-UNV-T3-BZ-HSS 87 5 R, N EXTERIOR SITE LIGHTING P3 EATON PRV-A15-D-UNV-T5-BZ 87 1 N EXTERIOR SITE LIGHTING P4 EATON 673-16-WP-L3/840-UNV-BM 20 6 D1 EXTERIOR WALL SCONCE P5 EATON XTOR2B-W-B2 18 8 K EXTERIOR WALL PACK P6 EATON XTOR3B-W-B2 26 3 P EXTERIOR WALL PACK V1 EATON 2BCLED-LD4-24HL-F-UNV-CD 29 4 E, F, WASHROOM VALIANCE E1 BEGHELLI SCA2HT30WWT40120-277JM 30 12 E GARBAGE CHUTE SYLVANIA LED8A/DIM/F/830 8 5 A4 EM 5 D1 PROVIDE EATON AALO6P SMART DIMMER FOR DOWN LIGHT CIRCUIT D OS-1 5 A1 D1 D1 D1 CEILING FAN OS-1 5 A1 A1 D1 A1 A1 A1 D1 D1 D1 LIGHTING ON CEILING FAN TO BE RELAMPED WITH SYLVANIA LED8-DIM-F-830 (TYPICAL OF 4) A1 A1 D1 D1 D1 EBP-C3 ENC1W12N60LJ 1 DESCRIPTION EATON 12ESL362LJ EBP-C1 D1 FIXTURE COUNT OLD FIXTURE TAG A1 V1 D1 MODEL NUMBER POWER PER FIXTURE (W) MANUFACTURER D1 D1 THESE DRAWINGS MUST BE CHECKED BY THE CUSTOMER OR CONTRACTOR. ANY ERRORS OR OMISSIONS MUST BE REPORTED IN WRITING TO STEENHOF BUILDING SERVICES GROUP PRIOR TO COMMENCEMENT OF CONSTRUCTION. 2. OWNER OR CONTRACTOR MUST CHECK AND VERIFY ALL SITE CONDITIONS BEFORE PROCEEDING WITH THE WORK. 3. ALL DIMENSIONS SHOWN ON THESE DRAWINGS MUST BE CHECKED AGAINST ALL OTHER PROJECT DRAWINGS. ALL DISCREPANCIES MUST BE REPORTED TO THE CONSULTANT BEFORE PROCEEDING WITH THE WORK. 4. FOR CONSTRUCTION PURPOSES, USE ONLY THE LATEST APPROVED DRAWINGS LABELLED 'ISSUED FOR CONSTRUCTION'. 5. DO NOT SCALE THE DRAWINGS. EXISTING FIXTURES TAG ENC1W12N60LJ EBP-C2 1. TRUE NORTH PROJECT NORTH REVISION SCHEDULE No. Description Date 1 ISSUED FOR TENDER 2017/03/28 2 ADDENDUM 2 2017/05/04 RANGE HOOD, CEILING FAN, STORAGE ROOM MALL ST COMMON ROOM BUILDING SCALE: N.T.S DRAWING NOTES: 1 EQUIPMENT TO BE REMOVED AND MADE SAFE. 2 NEW LIGHT POLE BASE. FIND AND REUSE EXISTING CONDUCTORS WHERE POSSIBLE. 4 EXISTING U/G CONDUCTORS PER DESIGN DRAWING "E1" ON "COULTER STREET FAMILY HOUSING" DRAWINGS DATED MAR 1 1990 LOCATION NOT CONFIRMED. PROVIDE NEW 20' STEEL POLE (ALUMINOUS SSQ4 OR EQUIVALENT). PROVIDE BASE PER “TYPICAL LIGHT POST BASE DETAIL” (S002). REUSE EXISTING 16"Ø CONCRETE BASE AS DETAILED IN SBSG'S ADDENDUM 1 LETTER SEALED MAY 3 2017. 5 NEW SWITCH BASED OCCUPANCY SENSOR TO REPLACE EXISTING SWITCH. 6 CHIP EXISTING BASES 18” BELOW GRADE, ABANDON REMAINING MATERIAL, AND REPAIR SOIL TO EXISTING. REFER TO STRUCTURAL ADDENDUM 1 LETTER DATED MAY 3 2017. N 1 6 NEW WALL PACKS LOCATED ON OUTBUILDING. 2 P5 2 P5 EBP-01A EBP-01A EMERGENCY LIGHT WITH DUAL REMOTE HEAD. EBP#1 INDICATES EMERGENCY BATTERY PACK A ON FLOOR 1. EMERGENCY LIGHT WITH SINGLE REMOTE HEAD. EBP#1 INDICATES EMERGENCY BATTERY PACK A ON FLOOR 1. WALL MOUNTED RUNNING MAN EXIT SIGN MOUNTED ON 4"x4" BACK BOX OS-3 D1 6 P1 4 2 D1 EMERGENCY BATTERY PACK C/W DUAL LIGHTING HEAD. EBP-01A INDICATES EMERGENCY BATTERY PACK A ON FLOOR 1. CEILING MOUNTED RUNNING MAN EXIT SIGN MOUNTED ON 4"x4" BACK BOX OS-1 D1 D1 TYPE 1 WALL MOUNTED OCCUPANCY SENSOR EQUAL TO SENSOR SWITCH WSX PDT SERIES C/W PIR AND MICROPHONIC DETECTION COULTER ST EM P5 P5 ELECTRICAL SYMBOLS EBP-01A N 1 D1 D1 D1 D1 P6 P6 PROJECT STATUS: N 1 6 N 1 NEW WALL PACKS FOR UNDERGROUND GARAGE RAMP 6 ADDENDUM #2 SEAL: D1 D1 TYPE 3 WALL MOUNTED OCCUPANCY SENSOR EQUAL TO SENSOR SWITCH WSX PDT 2P SERIES C/W PIR AND MICROPHONIC DETECTION AND INTEGRAL FAN CONTROL D1 D1 D1 D1 0024-17 May 4, 2017. P2 R 2 O 1 4 1 6 3 6 2 4 P6 P2 R 1 1 E100 2 PROJECT: P2 P3 2 4 6 4 BARRIE LIGHTING UPGRADE ADDRESS: 49 Coulter St, Barrie, ON P5 P2 R 2 2 4 N P2 1 6 2 4 1 6 N 1 6 O 1 6 STEENHOF Building Services Group 126 Mississaga St. E., Orillia, ON L3V 1V7 Tel: 705-325-5400 Fax: 705-325-8400 Website: www.steenhofbuilding.com PROJECT No.: 2 160547 SITE LIGHTING PLAN SCALE: N.T.S. DRAWN BY: M.S. DATE: Feb, 2017 CHKD BY: C.M. SCALE: nts DRAWING No.: SITE AND COMMON BUILDING LIGHTING PLAN 3 DWG TITLE: REVISION: E100 2 1. THESE DRAWINGS MUST BE CHECKED BY THE CUSTOMER OR CONTRACTOR. ANY ERRORS OR OMISSIONS MUST BE REPORTED IN WRITING TO STEENHOF BUILDING SERVICES GROUP PRIOR TO COMMENCEMENT OF CONSTRUCTION. 2. OWNER OR CONTRACTOR MUST CHECK AND VERIFY ALL SITE CONDITIONS BEFORE PROCEEDING WITH THE WORK. 3. ALL DIMENSIONS SHOWN ON THESE DRAWINGS MUST BE CHECKED AGAINST ALL OTHER PROJECT DRAWINGS. ALL DISCREPANCIES MUST BE REPORTED TO THE CONSULTANT BEFORE PROCEEDING WITH THE WORK. 4. FOR CONSTRUCTION PURPOSES, USE ONLY THE LATEST APPROVED DRAWINGS LABELLED 'ISSUED FOR CONSTRUCTION'. 5. DO NOT SCALE THE DRAWINGS. EBP-00C ENC 1 A6 EM 1 EBP-00D NXM A6 TRUE NORTH 1 EM 3 E101 BA BA BA BA EBP-00B NXM REVISION SCHEDULE A6 ENC EBP-00E 1 PROJECT NORTH No. Description Date 1 ISSUED FOR TENDER 2017/03/28 2 ADDENDUM 2 2017/05/04 BA A6 A6 ENC EBP-00D 2 TOTAL UNDERGROUND PARKING = 153 SPACES BB BB BB BB BB BB BB BB BB OS-1 SCALE: N.T.S STAIRWELL NUMBER 4 (UPPER LEVEL) SCALE: N.T.S UPPER LEVEL STAIR NO. 3 UPPER LEVEL STAIR NO. 4 BB BB BB 2 BB BA BB 3 BB BA BB STAIRWELL NUMBER 3 (UPPER LEVEL) ELEV ELEV 1 EBP-00A A6 EBP-00A ENC A6 BA BB A6 EBP-00A A6 A6 BB BA 2 EBP-00A OS-1 EBP-00A ENC ENC EBP-00A STAIR B EBP-00A ENC STAIR A BB BA WALKWAY EBP-00A BB BB BB BB BB BB BB BB BB DRAWING NOTES: 1 2 BB BB BB BB BB BB BB BB BB BB NEW SWITCH BASED OCCUPANCY SENSOR TO REPLACE EXISTING SWITCH. ADDENDUM #2 SEAL: 0024-17 May 4, 2017. BA EXISTING FIXTURE MISSING, NEW FIXTURE TO BE INSTALLED. CONNECT TO LINE VOLTAGE SIDE (NON-SWITCHED) OF NEAREST LIGHTING CIRCUIT. CONFIRM LOADING OF CIRCUIT IS LESS THAN 80% OF CIRCUIT BREAKER WHILE BATTERIES ARE CHARGING. PROJECT STATUS: BB D1 D1 BB D1 PROJECT: BARRIE LIGHTING UPGRADE BB BB BB BB ENC EBP-00B BB BB BB BB BB 2 E101 BB BB BB BB ADDRESS: 49 Coulter St, Barrie, ON A6 BA BA A6 STEENHOF Building Services Group 126 Mississaga St. E., Orillia, ON L3V 1V7 Tel: 705-325-5400 Fax: 705-325-8400 BA BA BA Website: www.steenhofbuilding.com PROJECT No.: 160547 DRAWN BY: M.S. DATE: Feb, 2017 1 BASEMENT AND UNDERGROUND PARKING LIGHTING PLAN CHKD BY: C.M. SCALE: nts DRAWING No.: BASEMENT AND UNDERGROUND LIGHTING PLAN BB BB BB BB A6 BB BB EBP-00A LOWER LOBBY BB EBP-00A VEST BA EBP-00A VEST BB BB BA ENC EBP-00A BB EBP-00A A1 BB A1 BB A1 BB A1 BB 2 EM OS-1 DWG TITLE: REVISION: SCALE: N.T.S E101 2 BX 1. THESE DRAWINGS MUST BE CHECKED BY THE CUSTOMER OR CONTRACTOR. ANY ERRORS OR OMISSIONS MUST BE REPORTED IN WRITING TO STEENHOF BUILDING SERVICES GROUP PRIOR TO COMMENCEMENT OF CONSTRUCTION. 2. OWNER OR CONTRACTOR MUST CHECK AND VERIFY ALL SITE CONDITIONS BEFORE PROCEEDING WITH THE WORK. 3. ALL DIMENSIONS SHOWN ON THESE DRAWINGS MUST BE CHECKED AGAINST ALL OTHER PROJECT DRAWINGS. ALL DISCREPANCIES MUST BE REPORTED TO THE CONSULTANT BEFORE PROCEEDING WITH THE WORK. 4. FOR CONSTRUCTION PURPOSES, USE ONLY THE LATEST APPROVED DRAWINGS LABELLED 'ISSUED FOR CONSTRUCTION'. 5. DO NOT SCALE THE DRAWINGS. BX 3 OS-1 2 EXISTING TO BE REPLACED C C A4 2 A6 KITCHEN BEDROOM BEDROOM EBP-01A LIVING/DINING BEDROOM A4 OS-1 D LAUNDRY ROOM D W A4 A4 A6 MOVING-IN A1 A6 D D D D A1 A1 A4 NEW FIXTURE A6 A1 A1 W A1 A6 A6 D EBP-01B D A4 W A6 A1 A6 D A1 W SORTING ROOM A1 A6 W V1 KITCHEN STORAGE E 2 OS-1 EBP-01B LIVING/DINING EBP-01A EBP-01A A2 A2 A2 A2 EBP-01A E36 EBP-01A STORAGE EM A2 A2 OS-3 OS-1 SUITE PANNEL A2 2 A4 W A4 A4 EBP-01B 2 OS1 EBP-01B EBP-01B A2 A3 A2 EBP-01B A2 EBP-01B EBP-01B REVISION SCHEDULE EBP-01B A3 3 ENTRY EBP-01B EBP-01A A2 A2 A4 LIVING/DINING EBP-01B A4 A4 BEDROOM K1 EBP-01B A3 A2 OS-1 BEDROOM BEDROOM 2 BEDROOM 3 OFFICE A4 2 A3 BEDROOM 1 LIVING 2 DINING A2 A2 OS-1 EXTERIOR STORAGE A1 1 EX 2017/05/04 A2 BEDROOM A4 ADDENDUM 2 EBP-01B A4 BATHROOM 2 OS-1 BIKES & PRAMS OS-1 A2 2017/03/28 E HALL ELECTRICAL ROOM STORAGE Date ISSUED FOR TENDER FILES A1 K1 EBP-01A BEDROOM A2 Description 1 2 WASHRM A4 No. TENANT STORAGE 2 OS-1 KITCHEN A4 PROJECT NORTH A3 A3 STORAGE WASHROOM E TRUE NORTH NEW SWITCH BASED OCCUPANCY SENSOR TO REPLACE EXISTING SWITCH. A2 2 1 BATHROOM W 2 V1 KITCHEN D 3 CONNECT TO LINE VOLTAGE SIDE (NON-SWITCHED) OF NEAREST HALLWAY LIGHTING CIRCUIT. CONFIRM LOADING OF CIRCUIT IS LESS THAN 80% OF CIRCUIT BREAKER WHILE BATTERIES ARE CHARGING. EBP-01B EBP-01B A2 1 A1 W OS-1 2 2 W EBP-01B EBP-01A A2 OS-1 OS-3 2 MECHANICAL ROOM OS-1 A1 A4 KITCHEN A3 EBP-01B BATHROOM BATHROOM A3 A1 A6 D DRAWING NOTES: EBP-01B A4 D TENANT STORAGE GENERATOR ROOM W A6 A4 LIVING/DINING A6 GARBAGE ROOM 2 OS-1 A4 A3 EBP-01B A3 EX EBP-01B EM K1 OS-1 K1 EBP-01B F F EBP-01A P4 P4 P4 1 2 2X 3X 4X 5X P4 6X 7X 8X 9X 10 11 FOR OUTDOOR LIGHTS: REPLACE TIMER WITH DIGITAL, 7-DAY, PROGRAMMABLE TIMER, AND REPLACE PHOTOCELL. THIS WILL ALLOW THE LIGHTS TO BE ACTIVATED AT DARK EACH NIGHT UNTIL A PREDETERMINED TIME SELECTED WITH THE LANDLORD (OR MIDNIGHT). P4 P4 1 FIRST FLOOR LIGHTING PLAN SCALE: N.T.S. EBP-02A EMERGENCY LIGHT SCHEDULE IS TYPICAL OF FLOORS 2, 3, 4, 5, 7, 8, 9, 10, 12, 14 BX C LIVING/DINING KITCHEN BEDROOM BEDROOM BEDROOM BEDROOM LIVING/DINING PROJECT STATUS: BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM ADDENDUM #2 KITCHEN BEDROOM SEAL: LIVING/DINING LIVING/DINING KITCHEN KITCHEN 0024-17 May 4, 2017. D BATHROOM BATHROOM BATHROOM KITCHEN STORAGE LIVING/DINING BATHROOM BATHROOM SUITE PANEL E1 BATHROOM STORAGE STORAGE KITCHEN STORAGE DRAWING NOTES: LIVING/DINING EBP-02A EBP-02A EBP-02A EBP-02A A2 A2 A2 A2 1 EBP-02A A2 A2 A2 EBP-02A A2 A2 A2 A2 CONNECT TO LINE VOLTAGE SIDE (NON-SWITCHED) OF NEAREST HALLWAY LIGHTING CIRCUIT. CONFIRM LOADING OF CIRCUIT IS LESS THAN 80% OF CIRCUIT BREAKER WHILE BATTERIES ARE CHARGING. EBP-02A A2 A2 KITCHEN STORAGE BATHROOM STORAGE STORAGE KITCHEN PROJECT: EBP-02A KITCHEN BATHROOM KITCHEN 1 EBP-02A BATHROOM EBP-02A BEDROOM EBP-02A BATHROOM K1 K1 TYPICAL BATTERY PACK LOCATION FOR ALL FLOORS EXCEPT FLOOR 5 AND 11. FOR FLOORS 5 AND 11 BATTERY PACK IS LOCATED IN ELECTRICAL ROOM LIVING/DINING (LOCATED BY ELEVATORS), SUBSTITUTE BATTERY PACK WITH REMOTE 2 HEAD EMERGENCY LIGHT. SEE DIAGRAMS 3 AND 4 ON DRAWING E103 FOR MORE DETAILS. STORAGE LIVING/DINING LIVING/DINING LIVING/DINING BEDROOM FLOORS 5 AND 11 HAVE ELECTRICAL ROOM IN THIS LOCATION. BATTERY PACK FOR FLOOR 5 AND 11 ARE LOCATED IN ELECTRICAL ROOM. SEE DIAGRAM 3 AND 4 ON E103 FOR MORE DETAILS. BEDROOM BEDROOM BEDROOM BARRIE LIGHTING UPGRADE EM E BEDROOM BEDROOM BEDROOM EBP-02A BEDROOM ADDRESS: 49 Coulter St, Barrie, ON STORAGE BEDROOM BATHROOM BATHROOM EX K1 EBP-02A EBP-02A STEENHOF Building Services Group 126 Mississaga St. E., Orillia, ON L3V 1V7 Tel: 705-325-5400 Fax: 705-325-8400 K1 F Website: www.steenhofbuilding.com PROJECT No.: 160547 1 2 2X 3X 4X 5X 6X 7X 8X 9X 10 11 DRAWN BY: M.S. DATE: Feb, 2017 2 TYPICAL FLOOR LIGHTING PLAN SCALE: N.T.S. CHKD BY: C.M. SCALE: NTS DRAWING No.: FIRST FLOOR AND TYPICAL FLOOR LIGHTING PLAN STORAGE DWG TITLE: REVISION: E102 2 1. THESE DRAWINGS MUST BE CHECKED BY THE CUSTOMER OR CONTRACTOR. ANY ERRORS OR OMISSIONS MUST BE REPORTED IN WRITING TO STEENHOF BUILDING SERVICES GROUP PRIOR TO COMMENCEMENT OF CONSTRUCTION. 2. OWNER OR CONTRACTOR MUST CHECK AND VERIFY ALL SITE CONDITIONS BEFORE PROCEEDING WITH THE WORK. 3. ALL DIMENSIONS SHOWN ON THESE DRAWINGS MUST BE CHECKED AGAINST ALL OTHER PROJECT DRAWINGS. ALL DISCREPANCIES MUST BE REPORTED TO THE CONSULTANT BEFORE PROCEEDING WITH THE WORK. 4. FOR CONSTRUCTION PURPOSES, USE ONLY THE LATEST APPROVED DRAWINGS LABELLED 'ISSUED FOR CONSTRUCTION'. 5. DO NOT SCALE THE DRAWINGS. DRAWING NOTES: 1 2 CONNECT TO LINE VOLTAGE SIDE (NON-SWITCHED) OF CORRIDOR LIGHTING CIRCUIT. CONFIRM LOADING OF CIRCUIT IS LESS THAN 80% OF CIRCUIT BREAKER WHILE BATTERIES ARE CHARGING. NEW SWITCH BASED OCCUPANCY SENSOR TO REPLACE EXISTING SWITCH. TRUE NORTH PROJECT NORTH REVISION SCHEDULE No. Description Date 1 ISSUED FOR TENDER 2017/03/28 2 ADDENDUM 2 2017/05/04 2 E103 ELEV P5 2 ELEV A4 A4 A4 A4 OS-1 1 P5 P5 EM 1 EBP-14B K1 EBP-14C K1 STAIR A EBP-14C ROOFTOP LIGHTING LAYOUT 1 SCALE: N.T.S PROJECT STATUS: ADDENDUM #2 SEAL: EBP-6A 2 A4 A4 3 OS-1 A5 EM A5 1 PROJECT: ELECTRICAL METER CLOSET - 6TH FLOOR BARRIE LIGHTING UPGRADE SCALE: N.T.S 1 A4 EBP-14A 0024-17 May 4, 2017. A4 ADDRESS: 49 Coulter St, Barrie, ON A5 A4 A5 1 EM EBP-11A STEENHOF Building Services Group 126 Mississaga St. E., Orillia, ON L3V 1V7 Tel: 705-325-5400 Fax: 705-325-8400 A4 Website: www.steenhofbuilding.com PROJECT No.: 160547 DRAWN BY: M.S. DATE: Feb, 2017 2 2ND FLOOR ROOFTOP MECHANICAL ROOM SCALE: N.T.S 4 ELECTRICAL METER CLOSET - 11TH FLOOR CHKD BY: SCALE: N.T.S DRAWING No.: C.M. SCALE: NTS 49 COULTER ROOFTOP LIGHTING LAYOUT, TYPICAL FLOOR DETAILS AND SAVE ON ENERGY CALCULATIONS SAVE ON ENERGY CALCULATIONS DWG TITLE: REVISION: E103 2