Preview only show first 10 pages with watermark. For full document please download

Ease Your Life!

   EMBED


Share

Transcript

ease yourlife security technology ease yourlife ease your life! 2011 PRODUCT CATALOGUE intruder & fire alarm systems leading manufacturer About us: TEKNIM is a ISO 9001:2008 certified manufacturer in Security Products market, located in IstanbulTurkey. We have our own Research & Development department and all our production facility in Turkey. TEKNIM, is a high-tech company, designed and produced Alarm Control Panel, Detectors, Other Fire Detection and Intruder Alarm Products, sell abroad and domestic markets through retailers. In this area, especially in very advanced and complete alarm systems technology development, design and production of Turkey's only and largest companies in the area is. Although TEKNIM is a very young company in Turkish market, leaving behind the world-leading brands and gained confidence of hundreds of companies and consumer alarm in a very short period and been market's leader company. TEKNIM, Alarm System, as well as from year 2008 Fire Detection Systems also designs and manufactures. Produced by TEKNIM Fire Alarm Panels and other fire products, appreciated by consumers and industry professionals are used to. TEKNIM, Turkey's largest manufacturer of alarm systems and the only exporter of bearing his name as TEKNIM is one of the most important brands. In addition to the success of Turkey, Teknim products are being exported to so many countries all over the World. Teknim's products are first choice of thousand users in many countries. TEKNIM, Intruder Alarm Systems, Fire Alarm Systems in the production along with the continued success and represents our country in abroad with the TEKNIM brand. contents INTRUDER ALARM SYSTEMS 4Alarm Panels . . . . . . . . . . . . . . . . . . 4 4Alarm Keypads. . . . . . . . . . . . . . . . 18 4Additional Modules . . . . . . . . . . . . 22 4Wireless Solutions . . . . . . . . . . . . . 26 4Detectors. . . . . . . . . . . . . . . . . . . . 28 4Outdoor Sirens . . . . . . . . . . . . . . . 34 4Alarm Sets . . . . . . . . . . . . . . . . . . . 35 CONVENTIONAL FIRE CONTROL SYSTEMS 4Fire Control Panels . . . . . . . . . . . . 38 4Extinguishant Control Panels . . . . . 41 4Detectors. . . . . . . . . . . . . . . . . . . . 42 ADDRESSABLE FIRE CONTROL SYSTEMS 4Fire Control Panels . . . . . . . . . . . . 46 4Repeaters. . . . . . . . . . . . . . . . . . . . 47 4Detectors. . . . . . . . . . . . . . . . . . . . 48 4Call Points . . . . . . . . . . . . . . . . . . . 51 4Indoor Sirens . . . . . . . . . . . . . . . . . 51 4Modules . . . . . . . . . . . . . . . . . . . . . 52 NEW Teknim TFD Series Detectors Designed and manufactured by Teknim for your safety... intruder alarm systems ALARM PANELS VAP-416 Alarm Control Panel VAP-416 Alarm Control Panel is the perfect high-end security and automation solution for medium and large sized residential and commercial areas. It is not only an alarm panel but also an automation system with 3 PGM outputs and periodic timers. Users may activate an electronic system such as irrigating system, aircondition, oven etc. in a determined time period by using PGM output. Users may arm/disarm panel and control PGM outputs remotely by phone. VAP-416 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VAPMAN Alarm Management Software. Its easy installation and user-friendly usage make it attractive both for installers and end users. Travel with a peace of mind... Because... metal box only General Features 16 + 16 zones • 16 zones on main control panel, expandable to 20 zones with optional zone expansion module and to 32 zones with hardwire zone-doubling. • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last-door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) • Selectable cross zone and double hit features to avoid from false alarm • Walking test for each zone • Bypassing each zone manually or automatically Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 3 programmable outputs - Can be increased to 8 PGM outputs with optional PGM relay module. - Can be used as siren output - Can be used as arm output - Can be used as fire siren output - Can be used as being active when determined zones are armed - Can be adjusted to output randomly - Can be used as selectable trouble output - Can be used as smoke detector power (for automatic resetting) 4 ALARM PANELS - Can be used as being active when there is a motion in determined zones or partitions - Can be used as being active in assigned time period - Can be used as magnetic or electro mechanic door lock controller output when using access control feature • Events which will be sent to the private phones can be selected • Sending delayed power failure report • Continuously telephone line check and alarms on lined failure • Distributing each private phone numbers and CMS numbers for related partitions 4 Partitions • Arming/disarming each partition together or separately • Smart Partition Technology; zones are automatically assigned to the related partitions • Using each partition as independent systems (keypad, zone, phone numbers, siren, users can be assigned independently) Users • Installer code: Able to command all settings related with installation • Master code: Able to command all settings related with users (Code, time setting... etc) • 27 user codes: Able to command arming/disarming of the panel - User authorization can be limited for determined time and operation • Temporary guest code: Has normal user rights for a day or one time usage • Duress code: Able to disarm the panel but the central stations and users are called • PC access code: Able to control the panel via VAPMAN management software 4 Keypads Connection • Each keypad has its own address. Keypads do not affect each other • Connecting LED and LCD keypads to the panel separately or together • Showing the motions only in specific zones by assigned partitions to the keypads • One key quick arming, partial arming (away, home, doors, windows... etc.) for each partition, by four special keys on the keypads • Producing warning sound (chime) by buzzer, when the specific zones become active or inactive • Automatic light activation of the determined zones (For example; when user opens the door, the keypad automatically illuminates) Power Supply • Short circuit protected 12V output (total 2A) • Extra auxiliary power for the siren • Extra auxiliary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check 256 event log memory with date and time information Communication by PC • Reading, setting and controlling all panel settings and reading event log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via onboard modem or from local network/internet via optional network module VPL-NET by using VAPMAN Alarm Management Software • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link modules VPL-232, VPL-USB, from remote PC via onboard modem or local network/internet via optional network module VPL-NET by using VAPMAN alarm management software Controlling remotely by phone • Arming/disarming of the panel • Controlling of PGM outputs • Getting information about panel status or PGM status Communicator • Including Contact ID and SIA formats • Calling 6 different private phone numbers (users) - Ability to deliver standard alarm warning signal - Ability to deliver voice message on any alarm by voice recording module VAV-210 or voice message module VAV- 218 • Calling 2 different central stations with secondary numbers • One key confirmation on incoming calls • Selecting communicator messages Arming/disarming alternatives • Partial arming/disarming • Automatic arming/disarming for a determined date and time period • Arming/disarming by remote controller • Arming/disarming by phone • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period 2 periodic timers • Can be used to control PGMs for determined hours and days Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) • 4 PGM relay module (TRM-904) • Network module (TPL-NET) • RS 232 Serial Communication Module (VPL-232) • USB Serial Communication Module (VPL-USB) • Remote control module (VAR-145) Keypad access limitation • As showing only determined partitions • As arming • As disarming • As accessing the programming Access control system • Using panel as an access control system for a door by connecting additional keypad to the door and assigning one user password and one PGM • Limiting access for determined date and time period Recommended keypads • VPC-350 Touch Screen keypad • VPC-301 LCD keypad • VPC-132 LED keypad • VPC-116 LED keypad (in the use of double zone feature, only supported zones can be seen) 5 ALARM PANELS VAP-408 P VAP-408 M VAP-408 P Alarm Control Panel VAP-408 Alarm Control Panel is the perfect high-end security and automation solution for medium and large sized residential and commercial areas. It is not only an alarm panel but also an automation system with 3 PGM outputs and periodic timers. Users may activate an electronic system such as irrigating system, aircondition, oven etc. in a determined time period by using PGM output. Users may arm/disarm panel and control PGM outputs remotely by phone. VAP-408 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VAPMAN Alarm Management Software. Its easy installation and user-friendly usage make it attractive both for installers and end users. We care about your home’s warmth as much as you do... VAP-408 M General Features 8 + 8 zones • 8 zones on main control panel, expandable to 12 zones with optional zone expansion module and to 16 zones with hardwire zone-doubling • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last-door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) • Selectable cross zone and double hit features to avoid from false alarm. • Walking test for each zone • Bypassing each zone manually or automatically Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 3 programmable outputs -Can be increased to 8 PGM outputs with optional PGM relay module - Can be used as siren output - Can be used as arm output - Can be used as fire siren output - Can be used as being active when determined zones are armed - Can be adjusted to output randomly - Can be used as selectable trouble output - Can be used as smoke detector power (for automatic resetting) 6 ALARM PANELS - Can be used as being active when there is a motion in determined zones or partitions - Can be used as being active in assigned time period - Can be used as magnetic or electro mechanic door lock controller output when using access control feature • Events which will be sent to the private phones can be selected. • Sending delayed power failure report • Continuously telephone line check and alarms on lined failure • Distributing each private phone numbers and CMS numbers for related partitions 4 Partitions • Arming/disarming each partition together or separately • Smart Partition Technology; zones are automatically assigned to the related partitions • Using each partition as independent systems (keypad, zone, phone numbers, siren, users can be assigned independently) Users • Installer code: Able to command all settings related with installation • Master code: Able to command all settings related with users (Code, time setting... etc) • 9 user codes: Able to command arming/disarming of the panel - User authorization can be limited for determined time and operation • Temporary guest code: Has normal user rights for a day or one time usage • Duress code: Able to disarm the panel but the central stations and users are called • PC access code: Able to control the panel via VAPMAN management software 4 Keypads Connection • Each keypad has its own address. Keypads do not affect each other • Connecting LED and LCD keypads to the panel separately or together • Showing the motions only in specific zones by assigned partitions to the keypads • One key quick arming, partial arming (away, home, doors, windows... etc.) for each partition, by four special keys on the keypads • Producing warning sound (chime) by buzzer, when the specific zones become active or inactive • Automatic light activation of the determined zones (For example; when user opens the door, the keypad automatically illuminates) Power Supply • Short circuit protected 12V output (total 1A) • Extra auxiliary power for the siren • Extra auxiliary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check 256 event log memory with date and time information Communication by PC • Reading, setting and controlling all panel settings and reading event log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via onboard modem or from local network/internet via optional network module VPL-NET by using VAPMAN Alarm Management Software • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link modules VPL-232, VPL-USB, from remote PC via onboard modem or local network/internet via optional network module VPL-NET by using VAPMAN alarm management software Controlling remotely by phone • Arming/disarming of the panel • Controlling of PGM outputs • Getting information about panel status or PGM status Communicator • Including Contact ID and SIA formats • Calling 6 different private phone numbers (users) - Ability to deliver standard alarm warning signal - Ability to deliver voice message on any alarm by voice recording module VAV-210 or voice message module VAV- 218 • Calling 2 different central stations with secondary numbers • One key confirmation on incoming calls • Selecting communicator messages Arming/disarming alternatives • Arming/disarming by a key • Partial arming/disarming • Automatic arming/disarming for a determined date and time period • Arming/disarming by remote controller • Arming/disarming by phone • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period 2 periodic timers • Can be used to control PGMs for determined hours and days. Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) •4 PGM relay module (TRM-904) • Network module (TPL-NET) • RS 232 Serial Communication Module (VPL-232) • USB Serial Communication Module (VPL-USB) • Remote control module (VAR-145) Keypad access limitation • As showing only determined partitions • As arming • As disarming • As accessing the programming Access control system • Using panel as an access control system for a door by connecting additional keypad to the door and assigning one user password and one PGM • Limiting access for determined date and time period. Recommended keypads • VPC-350 Touch Screen keypad • VPC-301 LCD keypad • VPC-116 LED keypad • VPC-108 LED keypad (in the use of double zone feature, only supported zones can be seen) 7 ALARM PANELS VAP-404 P VAP-404 M VAP-404 P Alarm Control Panel VAP-404 Alarm Control Panel is the perfect security solution for small and medium sized residential and commercial areas. It is not only an alarm panel but also an automation system with 2 PGM outputs and periodic timers. Users may activate an electronic system such as irrigating system, air-condition, oven etc. in a determined time period by using PGM output. Users may arm/disarm panel and control PGM outputs remotely by phone. VAP-404 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VAPMAN Alarm Management Software. Its easy installation and user-friendly usage make it attractive both for installers and end users. We care about your personal belongings as much as you do... VAP-404 M General Features 4 + 4 zones • 4 zones on main control panel, expandable to 8 zones with hardwire zonedoubling or optional zone expansion module • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last-door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) • Selectable cross zone and double hit features to avoid from false alarm • Walking test for each zone • Bypassing each zone manually or automatically Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 2 programmable outputs - Can be increased to 8 PGM outputs with optional PGM relay module. - Can be used as siren output - Can be used as arm output - Can be used as fire siren output - Can be used as being active when determined zones are armed - Can be adjusted to output randomly - Can be used as selectable trouble output - Can be used as smoke detector power (for automatic resetting) 8 ALARM PANELS - Can be used as being active when there is a motion in determined zones or partitions - Can be used as being active in assigned time period - Can be used as magnetic or electro mechanic door lock controller output when using access control feature • 1 armed output - Being active or inactive when the assigned partitions armed. 1 key Input • Being armed in toggle or level mode 4 Partitions • Arming/disarming each partition together or separately • Smart Partition Technology; zones are automatically assigned to the related partitions • Using each partition as independent systems (keypad, zone, phone numbers, siren, users can be assigned independently) 4 Keypads Connection • Each keypad has its own address. Keypads do not affect each other • Connecting LED and LCD keypads to the panel separately or together • Showing the motions only in specific zones by assigned partitions to the keypads • One key quick arming, partial arming (away, home, doors, windows... etc.) for each partition, by four special keys on the keypads • Producing warning sound (chime) by buzzer, when the specific zones become active or inactive • Automatic light activation of the determined zones (For example; when user opens the door, the keypad automatically illuminates) Power Supply • Short circuit protected 12V output (total 1A) • Extra auxiliary power for the siren • Extra auxiliary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check 256 event log memory with date and time information. Communication by PC • Reading, setting and controlling all panel settings and reading event log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via optional modem module TPL-MDM or from local network/internet via optional network module TPL-NET by using VAPMAN Alarm Management Software • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link modules VPL-232, VPL-USB, from remote PC via optional modem module TPL-MDM or local network/internet via optional network module TPL-NET by using VAPMAN alarm management software Controlling remotely by phone • Arming/disarming of the panel • Controlling of PGM outputs • Getting information about panel status or PGM status Communicator • Including Contact ID, DTMF 3+1, 3+2, 4+1, 4+2 formats • Calling 6 different private phone numbers (users) - Ability to deliver standard alarm warning signal - Ability to deliver voice message on any alarm by voice recording module VAV-210 or voice message module VAV- 218 • Calling 2 different central stations with secondary numbers • One key confirmation on incoming calls • Selecting communicator messages • Events which will be sent to the private phones can be selected • Sending delayed power failure report • Continuously telephone line check and alarms on lined failure • Distributing each private phone numbers and CMS numbers for related partitions Users • Installer code: Able to command all settings related with installation • Master code: Able to command all settings related with users. (Code, time setting... etc) • 5 user codes: Able to command arming/disarming of the panel. - User authorization can be limited for determined time and operation • Temporary guest code: Has normal user rights for a day or one time usage • Duress code: Able to disarm the panel but the central stations and users are called • PC access code: Able to control the panel via VAPMAN management software Arming/disarming alternatives • Arming/disarming by a key • Partial arming/disarming • Automatic arming/disarming for a determined date and time period • Arming/disarming by remote controller • Arming/disarming by phone • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period 2 periodic timers • Can be used to control PGMs for determined hours and days Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) • 4 PGM relay module (TRM-904) • Network module (TPL-NET) • RS 232 Serial Communication Module (VPL-232) • USB Serial Communication Module (VPL-USB) • Remote control module (VAR-145) • Modem Module (TPL-MDM) Keypad access limitation • As showing only determined partitions • As arming • As disarming • As accessing the programming Access control system • Using panel as an access control system for a door by connecting additional keypad to the door and assigning one user password and one PGM • Limiting access for determined date and time period. Recommended keypads • VPC-350 Touch Screen keypad • VPC-301 LCD keypad • VPC-108 LED keypad 9 ALARM PANELS VAP-308 P VAP-308 M VAP-308 P Alarm Control Panel VAP-308 Alarm Control Panel is the perfect security solution for medium and large sized residential and commercial areas. It is not only an alarm panel but also an automation system with PGM output and periodic timers. Users may activate an electronic system such as irrigating system, air-condition, oven etc. in a determined time period by using PGM output. VAP-308 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VAPMAN Alarm Management Software. Its easy installation and user-friendly usage make it attractive both for installers and end users. We care about your workplace as much as you do... VAP-308 M General Features 8 + 8 zones • 8 zones on main control panel, expandable to 12 zones with optional zone expansion module and to 16 zones with hardwire zone-doubling. • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) • Selectable cross zone and double hit features to avoid from false alarm. • Walking test for each zone • Bypassing each zone manually or automatically Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 1 programmable output - Can be used as siren output - Can be used as arm output - Can be used as fire siren output - Can be used as selectable trouble output - Can be used as smoke detector power (for automatic resetting) - Can be used as being active when there is a motion in determined zones - Can be used as being active in assigned time period 10 ALARM PANELS 2 Keypads can be connected • Each keypad has its own address. Keypads do not affect each other. • Connecting LED and LCD keypads to the panel separately or together. • Producing warning sound (chime) by buzzer, when the specific zones become active or inactive. • Automatic light activation of the determined zones. (For example; when user opens the door, the keypad automatically illuminates) Power Supply • Short circuit protected 12V output (total 1A) • Extra auxiliary power for the siren • Extra auxiliary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check 256 event log memory with date and time information. Communication by PC • Reading, setting and controlling all panel settings and reading event log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via optional modem module TPL-MDM or from local network/internet via optional network module TPL-NET by using VAPMAN Alarm Management Software. • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link modules VPL-232, VPL-USB, from remote PC via optional modem module VPL-MDM or local network/internet via optional network module VPL-NET by using VAPMAN alarm management software. Communicator • Including Contact ID , DTMF 3+1, 3+2, 4+1, 4+2 formats • Calling 6 different private phone numbers (users). - Ability to deliver standard alarm warning signal. - Ability to deliver voice message on any alarm by voice recording module VAV-210 or voice message module VAV-218 • Calling a central station with secondary number. • Selecting communicator messages. • Selecting events which will be sent to the private phones. • Delayed power failure report. Users • Installer code: Able to command all settings related with installation. • Master code: Able to command all settings related with users. (code, time setting.. etc) • 9 user codes: Able to command arming/disarming of the panel. - User authorization can be limited for determined time and operation. • Temporary guest code: Has normal user rights for a day or one time usage. • Duress code: Able to disarm the panel but the central stations and users are called. • PC access code: Able to control the panel via VAPMAN management software. Arming/disarming alternatives • Arming/disarming by a key. • Automatic arming/disarming for a determined date and time period. • Arming/disarming by remote controller. • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period. 2 weekly timers • Can be used to control PGMs Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) • RS 232 Serial Communication Module (VPL-232) • USB Serial Communication Module (VPL-USB) • Network module (TPL-NET) • Modem Module (TPL-MDM) • Remote control module (VAR-145) Recommended keypads • VPC-350 Touch Screen keypad • VPC-301 LCD keypad • VPC-016 LED keypad • VPC-116 LED keypad • VPC-108 LED keypad (in the use of double zone feature only supported zones can be seen) • VPC-104 LED keypad (in the use of double zone feature, only supported zones can be seen) Need to check your workplace? You can do it... TPL-NET Network & Internet Module 11 ALARM PANELS VAP-304 P VAP-304 M VAP-304 P Alarm Control Panel VAP-304 Alarm Control Panel is the perfect security solution for small and medium sized residential and commercial areas. It is not only an alarm panel but also an automation system with PGM output and periodic timers. Users may activate an electronic system such as irrigating system, air-condition, oven etc. in a determined time period by using PGM output. VAP-304 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VAPMAN Alarm Management Software. Its easy installation and user-friendly usage make it attractive both for installers and end users. We care about your beautiful garden as much as you do... VAP-304 M General Features 4 + 4 zones • 4 zones on main control panel, expandable to 8 zones with hardwire zonedoubling or optional zone expansion module • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last-door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) • Selectable cross zone and double hit features to avoid from false alarm • Walking test for each zone • Bypassing each zone manually or automatically Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 1 programmable output - Can be used as siren output, - Can be used as arm output, - Can be used as fire siren output, - Can be used as selectable trouble output. - Can be used as smoke detector power. (for automatic resetting) - Can be used as being active when there is a motion in determined zones. - Can be used as being active in assigned time period 12 ALARM PANELS Power Supply • Short circuit protected 12V output (total 1A) • Extra auxiliary power for the siren • Extra auxiliary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check 256 event log memory with date and time information Communication by PC • Reading, setting and controlling all panel settings and reading event log memory from a local PC via optional link modules VPL232, VPL-USB; from a remote PC via optional modem module TPL-MDM or from local network/internet via optional network module TPL-NET by using VAPMAN Alarm Management Software • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link modules VPL-232, VPL-USB, from remote PC via optional modem module TPL-MDM or local network/internet via optional network module TPL-NET by using VAPMAN alarm management software Communicator • Including Contact ID , DTMF 3+1, 3+2, 4+1, 4+2 formats • Calling 6 different private phone numbers (users) - Ability to deliver standard alarm warning signal - Ability to deliver voice message on any alarm by voice recording module VAV-210 or voice message module VAV-218 • Calling a central station with secondary number • Selecting communicator messages • Selecting events which will be sent to the private phones • Delayed power failure report Users • Installer code: Able to command all settings related with installation. • Master code: Able to command all settings related with users (code, time setting.. etc) • 5 user codes: Able to command arming/disarming of the panel -User authorization can be limited for determined time and operation • Temporary guest code: Has normal user rights for a day or one time usage • Duress code: Able to disarm the panel but the central stations and users are called • PC access code: Able to control the panel via VAPMAN management software. Arming/disarming alternatives • Arming/disarming by a key • Automatic arming/disarming for a determined date and time period • Arming/disarming by remote controller • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period 2 weekly timers • Can be used to control PGMs Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) • RS 232 Serial Communication Module (VPL-232) • USB Serial Communication Module (VPL-USB) • Network module (TPL-NET) • Modem module (TPL-MDM) • Remote control module (VAR-145) Recommended keypads • VPC-350 Touch Screen keypad • VPC-301 LCD keypad • VPC-108 LED keypad • VPC-104 LED keypad VAP Series Alarm Panels with New Plastic Box... Elegant Solutions for your safety... 13 ALARM PANELS VAP-358 P VAP-358 M VAP-358 P Wireless + Wired Alarm Control Panel VAP-358 is a hybrid system for both wireless and wired detectors. VAP-358 Alarm Control Panel is the perfect security solution for small and medium sized residential and commercial areas. It is not only an alarm panel but also an automation system with PGM output and periodic timers. Users may activate an electronic system such as irrigating system, air-condition, oven etc. in a determined time period by using PGM output. VAP-358 Alarm Control Panel can be controlled and monitored locally or remotely from a local PC or network/internet PC via VA P M A N A l a r m M a n a g e m e n t Software. Its easy installation and user-friendly usage make it attractive both for installers and end users. We care about your comfort as much as you do... VAP-358 M General Features 4 wireless + 4 wired zones • Wired zones on main control panel, expandable to 8 zones with hardwire zone-doubling or optional zone expansion module • Using each zone with NC or NO contacts devices with or without EOL resistors • Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) • Entry/Exit delays for each partition • Adjustable zone response speed • Additional features of the zones (Entry/exit zone, follower zone, last-door zone, zone with audio / silent…etc.) • Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door • Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren (for gas detectors, flood detectors) • Selectable cross zone and double hit features to avoid from false alarm. • Walking test for each zone • Bypassing each zone manually or automatically Outputs • 1 siren output - Negative or positive trigger - Adjusting cut off time between 2 to 255 min • 1 programmable output - Can be used as siren output, - Can be used as arm output, - Can be used as fire siren output, - Can be used as selectable trouble output. - Can be used as smoke detector power. (for automatic resetting) - Can be used as being active when there is a motion in determined zones. - Can be used as being active in assigned time period. 14 ALARM PANELS Power Supply • Short circuit protected 12V output (total 1A) • Extra auxilary power for the siren • Extra auxilary power for the keypad • Current limited battery charge circuit • Continuously mains power and battery check 256 event log memory with date and time information Communication by PC • Reading, setting and controlling all panel settings and reading event log memory from a local PC via optional link module VPLUSB; from a remote PC via optional modem module VPL-MDM or from local network/internet via optional network module VPLNET by using VAPMAN Alarm Management Software • Monitoring (zone, PGM or panel status) and controlling (arming/disarming, controlling of PGM outputs) panel from local PC via optional link module VPL-USB, from remote PC via optional modem module TPL-MDM or local network/internet via optional network module TPL-NET by using VAPMAN alarm management software Communicator • Supports Contact ID format • Calling 6 different private phone numbers (users) - Ability to deliver standard alarm warning signal - Ability to deliver voice message on any alarm by voice recording module VAV-210 • Calling a central station with secondary number • Selecting communicator messages • Selecting events which will be sent to the private phones • Delayed power failure report Users • Installer code: Able to command all settings related with installation • Master code: Able to command all settings related with users. (code, time setting.. etc) • 5 user codes: Able to command arming/disarming of the panel. -User authorization can be limited for determined time and operation • Temporary guest code: Has normal user rights for a day or one time usage • Duress code: Able to disarm the panel but the central stations and users are called • PC access code: Able to control the panel via VAPMAN management software Arming/disarming alternatives • Arming/disarming by a key • Automatic arming/disarming for a determined date and time period • Arming/disarming by remote controller • Arming/disarming by VAPMAN alarm management software • Inactivity arming within entered time period 2 weekly timers • Can be used to control PGMs Additional and optional modules • 4 zone expansion module (VAG-204) • Voice recording module (VAV-210) • USB Serial Communication Module (VPL-USB) • Network module (TPL-NET) • Modem module (TPL-MDM) Recommended keypads • VPC-350 Touch Screen keypad • VPC-301 LCD keypad • VPC-108 LED keypad • VPC-104 LED keypad Supported wireles devices: •ATW 614 Wireless PIR detector •ATW 114 Wireless magnetic contact •ATW 214 Wireless transmitter •ARC 844 Remote control 15 You are not at home but YOU CAN... ...shut the window shades, ...activate the irrigating system, ...turn on the oven to make your meal ready at the time you arrive home ...or turn on the heater and have your home warm in cold winter days before you come home... Teknim Security Technology, as one of the leading manufacturers of security sector in Turkey, we work for your life to be easier so you have more spare time for your beloved ones... You ensure your security with aesthetic, strong and easy to use high technology Teknim products, you don't even have to get up from where you sit... Anywhere in the World, the only thing you need is a mobile phone or a computer... 16 ALARM PANELS VAP Series Alarm Panels Comparison Table VAP Series Alarm Panels Comparison Table Features Zone+Zone doubling EOL resistor connection Connection option (NC,NO) Zone determination (fire, 24 hours, tamper...etc) Cross Zone and Double hit Walking Test Adjustable zone detection time Restriction of user authorization Programmable outputs Arm output Key Input Partition Smart Partition Technology (SPT) Partial arming Entry/Exit delays for each partition Automatic and manual by-pass Supported keypad connection Event log memory Line input /phone output Remotely control by phone Communicator Dialer Supported communication format User codes including master, installer, and PC access code Duress and Guest codes Time managed arming/disarming Arming/disarming by a key Partition management by a key Event code selection for communicator Access control system Remotely upload and download Monitoring and control from internet VAPMAN Alarm Management Software NC/NO options for siren and PGM outputs Continuously mains power and battery and check Continuously phone line check Voice recording module Remote controlling module Zone expansion module 4 PGM Relay Module PC link modules (RS232, USB) Network module Modem module Wireless Zone Module Adjustable siren cut off time VAP-304 P/M 4+4 0,1 or 2 Yes Yes Yes Yes Yes Yes 1 with PGM No 1 No No No Yes 2 256 Yes No Yes Yes Contact ID, .DTMF 3+1, 3+2, 4+1, 4+2 8 Yes Yes Yes No Yes No Optional Optional Standard Yes Yes No Optional Optional +4(optional) No Optional Optional No Optional Yes VAP-308 P/M 8+8 0,1 or 2 Yes Yes Yes Yes Yes Yes 1 with PGM No 1 No No No Yes 2 256 Yes No Yes Yes Contact ID , .DTMF 3+1, 3+2, 4+1, 4+2 12 Yes Yes Yes No Yes No Optional Optional Standard Yes Yes No Optional Optional +4(optional) No Optional Optional Optional Optional Yes VAP-404 P/M 4+4 0,1 or 2 Yes Yes Yes Yes Yes Yes 2 Yes Yes 4 Yes Yes Yes Yes 4 256 Yes Yes Yes Yes Contact ID , .DTMF 3+1, 3+2, 4+1, VAP-408 P/M 8+8 0,1 or 2 Yes Yes Yes Yes Yes Yes 3 with PGM No 4 Yes Yes Yes Yes 4 256 Yes Yes Yes Yes Contact ID and SIA VAP-416 16+16 0,1 or 2 Yes Yes Yes Yes Yes Yes 3 with PGM No 4 Yes Yes Yes Yes 4 256 Yes Yes Yes Yes Contact ID and SIA 12 Yes Yes Yes Yes Yes Yes Standard Optional Standard Yes Yes Yes Optional Optional +4(optional) Optional Optional Optional On board Optional Yes 32 Yes Yes Yes Yes Yes Yes Standard Optional Standard Yes Yes Yes Optional Optional +4(optional) Optional Optional Optional On board Optional Yes 4+2 8 Yes Yes Yes Yes Yes Yes Optional Optional Standard Yes Yes Yes Optional Optional +4(optional) Optional Optional Optional Optional Optional Yes Choose what you need... They were all produced for your safety... 17 ALARM KEYPADS VPC-350 Touch Screen Alarm Keypad Ease Your Life! 18 General Features 3,5" touch screen 320x240 pixels, 256K color resolution Easy and clear graphical user interface Voice orientations Home automation-oriented control features (Manual or automatically manage lights, louvers, curtains...etc) ¡ Event log memory review and filter ¡ Detailed screen view for important datas like zone status, failure status...etc ¡ Thermometer feature. Can be used as room thermostat, control devices like heater and air conditioner on keypad directly ¡ Optional card reader ¡ Compact & elegant design ¡ Black or white color options ¡ ¡ ¡ ¡ ¡ ALARM KEYPADS VPC-301 B LCD Keypad ¡ Programmable zone names. ¡ Backlit, two lines, 32 character LCD screen. ¡ Adopted with all VAP Series Panels. It can be used with other VPC-301 LCD Keypad has been designed to control all VAP series alarm panels. It can be adopted to all decorations with its esthetic design. VAP series keypads. ¡ Backlit, multi-functional silicone keys. ¡ Backlighting boost ¡ 4 special buttons for each partition for quick & partial arm with backlight and activation light. ¡ Internal buzzer. ¡ Ability to read event log. ¡ Automatic key light when a motion detected in a determined zone. ¡ Chime feature (warning with sound and light when the determined zones active or inactive) ¡ Smoke detector reset connected to the PGM by keypad ¡ Special keys for panic, fire and duress alarm. ¡ Energy saving mode for energy cutting. ¡ Auto protection for wrong passwords entered 5 times. ¡ Sabotage switch. (no need additional cable) ¡ On screen programming ¡ Alternately on screen thermometer/time/date and auxiliary texts ¡ Easy programming by menu system. ¡ Multi-language support ¡ Menu system, short keys and direction keys for easy programming ¡ Two different keypad lights: Green (standard), Blue (optional) VPC-132 LED Keypad Backlit, multi-functional silicone keys. Adopted with all VAP Series Panels with 4-32 zones. It can be used with other VAP series keypads (except VPC-104 and VPC-016) at the same panel. < Backlit 4 partition zone designed for partial arm with a key. < Different led for each zone. < Internal buzzer. < Ability to read event log. < Special keys for panic, fire and duress alarm. < Energy saving mode for mains failure. < Automatic key light when a motion detected in a determined zone. < Chime feature (warning with sound and light when the determined zones active or inactive) < Auto protection for wrong passwords entered 5 times. < Smoke detector reset connected to the PGM by keypad < Sabotage switch. (no need additional cable) < Easy programming features. < Two different keypad light: Green (standard), blue (optional) < < VPC-132 thirty two-zone is esthetic and smart LED keypad has been designed to control VAP series alarm panels. It is possible to control all features of VAP series alarm panels by VPC-132. 19 ALARM KEYPADS VPC-116 LED Keypad ¡ Backlit, multi-functional silicone keys. ¡ Adopted with all VAP Series Panels with 4-16 zones. It can be used with other VAP series keypads (except VPC-104) at the same panel. ¡ Backlit 4 partition zone designed for partial arm with a key. ¡ Different led for each zone. ¡ Internal buzzer. ¡ Ability to read event log. ¡ Special keys for panic, fire and duress alarm. ¡ Energy saving mode for mains failure. ¡ Automatic key light when a motion detected in a determined zone. ¡ Chime feature (warning with sound and light when the determined zones active or inactive) ¡ Auto protection for wrong passwords entered 5 times. ¡ Smoke detector reset connected to the PGM by keypad ¡ Sabotage switch. (no need additional cable) ¡ Easy programming features. ¡ Two different keypad light Green (standard), blue (optional) VPC-116 sixteen-zone is esthetic and smart LED keypad has been designed to control all features of VAP series alarm panels with 4-16 zones. VPC-108 LED Keypad ¡ Backlit, multi-functional silicone keys. ¡ Adopted with all VAP Series Panels have 4-8 zones. It can be used with other VAP series keypads (except VPC-104) at the same panel. ¡ Backlit 4 partition zone designed for partial arm with a key. ¡ Different led for each zone. ¡ Internal buzzer. ¡ Ability to read event log. ¡ Special keys for panic, fire and duress alarm. ¡ Energy saving mode for mains failure. ¡ Automatic key light when a motion detected in a determined zone. ¡ Chime feature (warning with sound and light when the determined zones active or inactive) ¡ Auto protection for wrong passwords entered 5 times. ¡ Smoke detector reset connected to the PGM by keypad ¡ Sabotage switch. (no need additional cable) ¡ Easy programming features. ¡ Two different keypad light Green (standard), blue (optional) VPC-108 eight-zone is esthetic and smart LED keypad has been designed to control VAP series alarm panels with 4 to 8 zones. 20 ALARM KEYPADS VPC-104 LED Keypad ¡ Backlit, multi-functional silicone keys. ¡ 7 segment red screens display the moving zones and messages. ¡ Internal buzzer. ¡ Ability to read event log. ¡ Special keys for panic, fire and duress alarm. ¡ Energy saving mode for mains failure. ¡ Automatic key light when a motion detected in a determined zone. ¡ Chime feature (warning with sound and light when the determined zones active or inactive) ¡ Auto protection for wrong passwords entered 5 times. ¡ Smoke detector reset connected to the PGM by keypad ¡ Sabotage switch. (no need additional cable) ¡ Easy programming features. VPC-104 eight-zone, functional, smart and economic LED keypad have been designed to control all features of the VAP-304 Alarm Panel. VPC Series Keypads Comparison Table Features VPC-104 VPC-108/116/132 VPC-301 Backlit, two lines, 32 character LCD screen Backlit, long lived silicone keys Backlighting boost Back lighted 4 partition zone designed for partial arm with a key Internal buzzer Automatic key light when a motion detected in a determined zone Chime feature (warning with sound and light when the determined zones active or inactive) Special keys for panic, fire and duress alarm Energy saving mode Easy programming by menu system Multi-language support On screen thermometer/time/date Auto protection for wrong passwords entered 5 times 7 Segment LED screen No Yes No No Yes No Yes Yes Yes No No No Yes Yes No Yes No Yes Yes Yes Yes Yes Yes No No No Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No 21 ADDITIONAL MODULES TPL-NET Network & Internet Module Anywhere in the World, no need any software, just by using an internet browser, you can arm/disarm your security system and check the zones... Using TPL-NET Module, you can manage the security of your home or office via your cell phone* wherever you are... VAPMAN Alarm Management Software lets users and installers to control and set VAP Series Alarm Panels from a local/remote PC or internet via serial ports, modem or network... * This feature is only available on the cell phone with an internet connection… 22 ADDITIONAL MODULES VAPMAN Alarm Management Software Installers; Accessing panel from a local/remote PC or internet by using remote access code and installer code. < Making all installer settings which can be done with keypad. < Loading saved panel settings in their computer during installation. < Saving settings of the installed panel to their computer, and when a problem occurs, they can reach necessary information easily. If necessary, corrupted settings can be re-load. < Solving the panel troubles by remote communication. Saving customer details. (For ex; name, phone, panel type…etc.) < Downloading event log. (event log can be printed out or saved as .xls file) < Master Users; Accessing control panel from a local/remote PC or internet by using remote access code and master user code. < Making all master user settings (time/date settings, keypad < settings, user authorizations, user codes…etc) which can be done with keypad. < Controlling the panel (arming/disarming panel, controlling PGMs, by-passing, testing siren, PGM, user/CMS phones …etc.) < Monitoring panel status online. < Downloading event log. (event log can be printed out or saved as .xls file) Users; Accessing control panel from a local/remote PC or internet by using remote access code and user code. < Controlling the panel according to authorization given by master user. (Arming/disarming, controlling PGMs, by-passing, testing siren, PGM, user/CMS phones …etc.) < Monitoring panel status online according to authorization given by master user. < Downloading event log. (event log can be printed out or saved as .xls file) < VAV-264 Voice Message Module Alarm panel detects events, when users call in during the event by type of event that transmits voice messages as. Each event is recorded as a factory for the type of voice recording and can not be changed. 23 ADDITIONAL MODULES VAR-145 Remote Control Module VAR-145 remote control module has been developed to control VAP series panel remotely. User can arm (home/away) or disarm the panel or give panic alarm by remote control device ARC-844. User can activate the siren or send message to the central station by pressing to the panic button. This module supports 7 remote control devices. Esthetic remote control device with 4 keys (Arming home, arming away, disarm, and panic buttons) < 128 bit safety, can not decoded/copied, Rolling code < Adjusting panic button as audio or silent < 433.92 MHz frequency < Supporting 7 remote control devices < High sensitivity with its special antenna < 5V, 20mA power supplied from alarm panel < VPL-USB PC Link Module VPL-USB PC Link Module supplies communication between all VAP series alarm panels and local PC via USB port. Users can read, change and control all panel settings, read event log memory, monitor and control panel status from a local PC by using VAPMAN alarm management software via VPL-USB PC Link Module. < < < Adopted with all VAP series alarm panels 5V, 20mA power supplied from alarm panel 90 x 50 mm dimensions TPL-MDM Modem Module TPL-MDM Modem Module supplies communication between all VAP series alarm panels and remote PC via PSTN port. Users can read, change and control all panel settings, read event log memory, monitor and control panel status from a remote PC by using VAPMAN alarm management software via TPL-MDM Modem Module. < Standard in VAP 408 and VAP 416 Alarm Panels and adopted with VAP 304, VAP 308 and VAP 404 Alarm Panels < 5V, 50mA power supplied from alarm panel < 90 x 50 mm dimensions 24 ADDITIONAL MODULES VAV-210 Voice Recording Module VAV-210 Voice Recording Module supplies to send recorded alarm message to the users during alarm instead of alarm warning signal. User can record an alarm message up to 20 sec by using microphone on the module. Since the message is recorded in the flash memory on the module, the recorded message is not deleted during power cut. < < < < 20 sec. voice recording Adopted with all VAP series alarm panels 5V, 20mA power supplied from alarm panel 90 x 50 mm dimensions TRM-904 PGM Relay Output Module TRM-904 PGM Relay Output Module supplies total 4 PGM Relay output for VAP 404, VAP 408 and VAP 416 alarm panels. This module ensures the same PGM features supplied by adopted alarm panels. Adopted with VAP-404, VAP-408 and VAP-416 alarm panels Using max. 2 modules in a panel and by this way; increasing total PGM output amount to 8 < 240V, 7A NC/NO relay contacts < 5V, 150mA power supplied from alarm panel < 90 x 50 mm dimensions < < VAG-204 4 Zones Expansion Module VAG-204 4 zones Expansion Module supplies 4 additional zones to VAP series alarm panels. This module ensures the same zone features supplied by any VAP series alarm panel. < < < Adopted with all VAP series alarm panels 5V, 20mA power supplied from alarm panel 90 x 50 mm dimensions 25 WIRELESS SOLUTIONS ATR-244 Wireless Receiver Module Developed for use VAP Series alarm panels with wireless detectors and keyfob remote controllers. Total 7 wireless devices are supported. n n n n n High reception sensitivity antenna. 433.92 MHZ working frequency Easy learn / erase operation No external power required Dimensions ; 90 x 50 mm ARC-844 Remote Control Aesthetic ·design with 4 button (Arming home, away, disarm and panic) n 128 bit encrypted rolling code system n Customizable panic button n 433.92 MHZ working frequency n Long life 12V, 27A type alkaline battery n ATW-114 Wireless Magnetic Contact 1 pc. wired zone input Double tamper switch againts removal from wall or cover opening n Supervised n 433,92 MHZ working frequency n Activation LED n Up to 3 years battery life, 3V Lithium battery n Pico power technology, very low current drain n Microprocessor operated n n Technical Specifications Battery Current consumption Detection distance Operating frequency Tamper switch Activation LED RFI Immunity Humidity Temperature Dimensions (W X H X D) 26 3V, CRI23 Lithium 3μA, standby/ 6mA transmittin 10-15mm 433.92MHz N.C. (cover or wall removal) Red Average 20V/m (10 MHz - 2 GHz.) %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm WIRELESS SOLUTIONS ATW-614 Wireless PIR Detector < < < < < < < < < < < Selectable pulse counts to prevent the false alarm Recomended for ceiling, wall and corner fitting Cable canals at back side Tamper alarm output Strong mounting foot Integrated onboard jumper selectable Supervised 433 Mhz operating frequency Up to 3 year battery life Very low current consumption Microprocessor controlled Technical Specifications 110 Top view Infrared sensor Battery Current drain Detection range Operating frequency Pulse count Tamper switch Activation LED RFI Immunity Detectable speed Mounting height Humidity Temperature Dimensions (W X H X D) 0 0.3] R34[1 R60[12.3] R10[2.9 ] R16[4.9] Side view 10[2.9] 16[4.9] 34[10.3] 60[12.3] Dual element 3V, CRI23 Lithium 20μA, standby/ 10mA transmitting 12m@110° 433.9MHz Selectable 1/2/3 N.C. (cover open and wall removal activated) Red, can be disable Average 20V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sec. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm ATW-214 Wireless Universal Transmitter < < < < < < < < 1 pc wired zone input Double tamper switch against removal from wall or cover opening Supervised 433,92 MHz working frequency Activation LED Up to 3 years battery life, 3V Lithium battery Pico power technology, very low current drain Microprocessor operated Technical Specifications Battery Current consumption Detection range Operating frequency Tamper switch Activation LED RFI Immunity Humidity Temperature Dimensions (W X H X D) 3V, CRI23 Lithium 3μA, standby/ 6mA transmitting 12m@110° 433.9MHz N.C. (cover open and wall removal activated) Red Average 20V/m (10 MHz - 2 GHz.) %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm 27 DETECTORS ATP-510S Passive Infrared Detector n n n n n n Selectable pulse counts to prevent the false alarm Recommended for ceiling, wall and corner fitting Cable canals at back side Tamper alarm output Strong mounting foot Integrated onboard jumper selectable EOL Technical Specifications 110 Top view 0 0.3] R34[1 R60[12.3] R10[2.9 ] R16[4.9] Side view 10[2.9] 16[4.9] 34[10.3] 60[12.3] Dual element 9-16 VDC, 12V 20mA, 12VDC 18m@130° N.C. 30VDC, 0.2A max. Selectable 1/2/3 N.C. (cover open and wall removal activated) Red, can be disable Average 10V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sec. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm Infrared sensor Power requirement Current drain Detection range Alarm output Pulse count Tamper switch Activation LED RFI Immunity Detectable speed Mounting height Humidity Temperature Dimensions (W X H X D) ATP-540N Digital PIR Detector n n n n n n n n n n Dual element digital sensor Ultra sensitive with 14 bit resulation Digital signal processing by microcontroller Smart algoritm against false alarm Sensitivity adjustment by trimpot Pulse count options (1/2/3) Suitable for ceiling, wall and corner fitting Cable canals at back side Tamper alarm output Strong mounting foot Technical Specifications Infrared sensor Power requirement Current drain Detection range Alarm output Pulse count Sensitivity adjustment Tamper switch Activation LED RFI Immunity Detectable speed Mounting height Humidity Temperature Dimensions (W X H X D) 28 Digital, dual element 9-16 VDC, 12V 20mA, 12VDC 14m@110° N.C. 30VDC, 0.2A max. 1/2/3 selectable By trimpot N.C. (cover open and wall removal activated) Red, can be disable Average 20V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sec. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm 110 0 Top View 1.7] R38[1 R46[14] R11[3.3 ] R18[5.6] Side View 11[3.3] 18[5.6] 38[11.7] 46[14.0] DETECTORS ATP-540LR Long Range Digital Passive Infrared Detector n n n n n n n n n n n 20m long range Dual element digital sensor Ultra sensitive with 14 bit resulation Digital signal processing by microcontroller Smart algoritm against false alarm Sensitivity adjustment by trimpot Pulse count options (1/2/3) Suitable for ceiling, wall and corner fitting Cable canals at back side Tamper alarm output Strong mounting foot Technical Specifications Top View 75 R1 0 .0] 3[4 3[7 .0] R2 .2] [20 R40 R8[2.4] Side View 8[2.4] 13[4.0] 23[7.0] 40[20.2] Digital, dual element 9-16 VDC, 12V 20mA, 12VDC 20m@75° N.C. 30VDC, 0.2A max. 1/2/3 selectable By trimpot N.C. (cover open and wall removal activated) Red, can be disable Average 20V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sec. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm Infrared sensor Power requirement Current drain Detection range Alarm output Pulse count Sensitivity adjustment Tamper switch Activation LED RFI Immunity Detectable speed Mounting height Humidity Temperature Dimensions (W X H X D) ATP-540P Pet Immune Digital PIR Detector < < < < < < < < < < Temperature compensated Ultra sensitive Digital Technology High false alarm sensibility Selectable pulse counts to prevent the false alarm Recommended for ceiling, wall and corner fitting Cable canals at back side Tamper alarm output Walking test Using without mounting foot because of pet immunity feature Technical Specifications Infrared sensor Power requirement Pet Immunity Current drain Detection range Alarm output Pulse count Sensitivity adjustment Tamper switch Activation LED RFI Immunity Detectable speed Mounting height Humidity Temperature Dimensions (W X H X D) Digital, dual element 9-16 VDC, 12V Up to 18kg and 60cm 20mA, 12VDC 10m@90° N.C. 30VDC, 0.2A max. Selectable 1/2/3 By trimpot N.C. (cover open and wall removal activated) Red, can be disable Average 20V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sec. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm Top View 90 R1 0 .0] 3[4 3[7 .0] R2 .2] [10 R40 R8[2.4] Side View 8[2.4] 13[4.0] 23[7.0] 40[10.2] 29 DETECTORS ATP-560 Dual Technology Motion Detector n n n n n Alarm outputs when PIR and Microwave detect simultaneously Adjustable sensitivity to prevent false alarm Recommended for ceiling, wall and corner fitting Tamper alarm output Mounting foot Technical Specifications Top View 90 R1 0 .0] 3[4 3[7 .0] R2 .2] [10 R40 R8[2.4] Side View 8[2.4] 13[4.0] 23[7.0] 40[10.2] Dual element and pyroelectric 10.525 Ghz. 9-16 VDC, 12V 50mA @ 12VDC 10m @ 90° N.C. 30VDC, 0.2A max. N.C. (cover open activated) Red, yellow, green can be disable Average 10V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sec. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm Infrared sensor Microwave Sensor Power requirement Current drain Detection range Alarm output Tamper switch Activation LED RFI Immunity Detectable speed Mounting height Humidity Temperature Dimensions (W X H X D) ATP-570 Dual Technology Motion Detector n n n n n n n n n n Fully digital Antimasking And / or selection for alarm output High RF immunity Separate adjustable sensitivity for microwave and PIR Pulse count Suitable dor ceiling, wall and corner fitting Tamper alarm output Strong mounting foot 3 color indicator Technical Specifications Infrared Sensor Microwave Sensor Power Requirement Detection Range Alarm Output Tamper Switch Activation LED RF Immunity Detectable speed Mounting Height Humidity Temperature Dimensions (W X H X D) 30 Dual element, digital 10.525 Ghz. 9-16 VDC, 50mA @ 12V 12m@110° NC 30VDC, 0.2A max. NC (cover open activated) Red, yellow and green (can be disabled) Avg. 20V/m (10 MHz - 2 GHz.) 0,3 1.5 m/sn. 2.1m %95 RH (maximum) -20C 60C (-4F 140F) 108 x 63 x 50 mm 90 Top View R1 0 .0] 3[4 3[7 .0] R2 .2] [10 R40 R8[2.4] Side View 8[2.4] 13[4.0] 23[7.0] 40[10.2] DETECTORS Mounting Foot for ATP Series PIR Detectors n This strong mounting foot can be adopted all ATP Series PIR Detectors n It is designed to supply wall, corner and ceiling mounting options for installers n 45° left/right, 15° downward adjustment possible with 5° steps TFD-1450 Optical Smoke + Heat Multisensor TFD-14xx series detectors are remarkable for their special and modern low profile design, that makes them suitable of the most demanding and prestigious interior. The bases designed and manufactured with care for the installers allow easy installation and provides interchangeability of the fire detectors from the series. TFD-1450, is an Optical Smoke + Heat Multisensor were designed with precise CPU control and thermister detection. It is state of the art combination of 'Optical Smoke' and 'Fixed Temperature' ensures the best quality of heat detection in all environment. Detectors were engineered to the best quality and durability. They work perfectly with all intruder alarm control panels. 4 wire model, NC relay output Advanced detection and discrimination algorithms n Durable sensor head, no need for replacement n SMD circuit board design-satisfactory quality and reliability quarenteed n Plastic, white housing high temperature endurable and fireproof polymeric material n Alarm indicator LED, continuosly emitting red light n Easy installation and maintenence n Sleek low-profile housing design n High quality and reliability guarenteed n Strong body n Designed to comply with European and US standarts n Base Included n n 31 DETECTORS TFD-1430 Optical Smoke Detector TFD-1430, is an Optical Smoke Detector provides reliable early warning of intense fires with fast response by detection smoke particles. It has the function of dustproof, mothproof, and anti-electromagnetic interference. It performs well in detecting visible smoke caused by hidden or bright fire. It is suitable for detecting smoke in houses, stores, hotels and warehouses, etc. Detectors were engineered to the best quality and durability. They work perfectly with all intruder alarm control panels. 4 wire model, NC relay output Advanced detection and discrimination algorithms n Durable sensor head, no need for replacement n SMD circuit board design-satisfactory quality and reliability quarenteed n Plastic, white housing high temperature endurable and fireproof polymeric material n Alarm indicator LED, continuosly emitting red light n Easy installation and maintenence n Sleek low-profile housing design n High quality and reliability guarenteed n Strong body n Designed to comply with European and US standarts n Base Included n n TFD-1410 Heat Detector TFD-1410, is a Heat Detector provides reliable early warning of a fire condition upon ambient temperature reaching a fixed temperature threshold. Detectors were engineered to the best quality and durability. They work perfectly with all intruder alarm control panels. 4 wire model, NC relay output Detectionof intense fires with fast response under rapid temperature-rise situation n SMD circuit board design-satisfactory quality and reliability quarenteed n Mechanical moving parts provide stability, durability and reliability n Self-restoring bimetal elements allow continual use n Plastic, white housing high temperature endurable and fireproof polymeric material n Alarm indicator LED, continuosly emitting red light n Easy installation and maintenence n Sleek low-profile housing design n High quality and reliability guarenteed n Strong body n Designed to comply with European and US standarts n Base Included n n 32 DETECTORS ATS-3232 General Features Adjustable limit temperature range 32°C~ +32°C (with 1°C increments) < Three different working modes; over limit, under limit, out-window mode (window can be adjusted ±1°C ~ ±8°C) < Ultra sensitive digital temperature sensor < Compatible with all VAP series and other brands' alarm panels < RS232 port to integrated automation systems < Activation LED < Strong body < Solid state relay < All settings can be done by DIP switches < Universal Limit Temperature Detector ATS series limit temperature sensor is developed to warn/alarm if the measured temperature goes beyond determined limits and/or communicate with CMS. It is compatible with all VAP series and other companies alarm panels. Has 3 different modes; - When temperature goes over the determined value, Technical Specifications - When temperature goes below the Adjustable Temperature Limit Temperature Tolerance Power supply Humidity Dimensions determined value, -32°C _ +32°C Adjustable between ±1°C ~ ±8°C 9-16V DC 95% RH (maximum) 108x63x50mm or - When temperature goes beyond the upper an lower values. Suitable to use in places that temperature value must stay in some specific limits for ex: cold stores, biologic laboratories, meat packing houses, food and beverage storages of markets...etc. Another remarkable and functional product... Designed and manufactured by Teknim... 33 OUTDOOR SIRENS VAS-740 Outdoor Siren Walking LEDs with 6 super bright LEDs Intelligent trigger system that no jumper setting n Internal or external power supply option during alarm n Intelligent tamper detection system on power line n Strong ABS housing with 3 mm thickness n Internal metal protection covers electronic circuit and components n Microprocessor controlled n Tamper protection for removal of the top cover from the body of the siren or removal of the siren from the wall n Strong LED strobe n Two different siren pattern n Automatic cutoff with two option (3 or 10 min) n Internal rechargeble battery n Two different siren tone n Wide and smooth area for company logo n Easy mounting n n Technical Specifications Power Requirement Frequency Sound Level @ 1 m Internal battery Current at EXT mode Current at INT mode Stand by current Dimensions (W X H x D) Weight 9-14VDC, Nominal 12VDC 1400-3000Hz. 118dB max. 6 V, 330mAh 300mA with flasher @ 12V 25mA @ 12V 25mA 215 x 300 x 60 mm 1.354 gr. VAS-720 WR/ WB Outdoor Siren Strong ABS housing with 3 mm thickness n Internal metal protection covers electronic circuit and components n Microprocessor controlled n High sound level with piezo n Tamper protection for removal of the top cover from the body of the siren or removal of the siren from the wall n Strong strobe n Sliding 2 leds n Auto-tamper n Automatic inactivation option of the siren n Internal rechargeable battery n Two different siren speeds n Suitable for both positive or negative trigger n Power voltage from battery or panel during alarm (SAB or SCB) n Negative tamper option n Wide and smooth area for company logo n Easy mounting n Blue and red versions n Technical Specifications Power Requirement Frequency Sound Level @ 1 m Internal battery Current at SAB mode (@ 12V) Current at SCB mode (@ 12V) Strobe current (@ 12V) Stand by current (@ 12V) Strobe frequency (@ 12V) Dimensions (W X H x D ) Weight 34 9-14VDC, Nominal 12VDC 1400-3000Hz. 118dB max. 6 V, 330mAh 200mA 25mA 100mA 10mA 1.0 Hz. 215 x 300 x 60 mm 1.354 gr. ALARM SET VAP-304 ALARM SET VAP-304 P Alarm Panel for more information please refer to page 12 VAS-740 Outdoor Siren for more information please refer to page 34 ATP-510S PIR Detector including mounting foot for more information please refer to page 28 VPC-104 Alarm Keypad for more information please refer to page 21 4+4 zones (zone doubling) External sounder with audible and visible warning Simple Installing... Easy Programming... User Friendly... 2 keypad connections supported 256 event log memory with date and time information 10 codes: 5 users, 1 master, 1 PC access, 1 duress, 1 guest, 1 installer Phone dialer (6 users' phones) 1 PGM, 1 siren output Ability to deliver information to Central Monitoring Station by Contact ID Communicator All necessary equipments are in this box... For your beloved ones' safety... 35