7.5(19.05) Installation and maintenance of this system should be done by authorized personnel only. Bosch Security Systems recommends testing the entire system at least once a week, and having a qualified technician check the system at a minimum of once a year.
ICP-EZM2
This equipment was tested and found to comply with the specifications in Part 15 of FCC rules for Class B Computing Devices. Operation is subject to the two following conditions (1) this device must not cause any interference, and (2) this device must accept any interference received including interference that might cause undesired operation. Complies with Part 68, FCC rules. FCC Registration Number: US:ESVAL00BEZ1. Ringer Equivalency Number (REN): 0.0B.
Install this equipment according to Chapter 11 of the National Fire Alarm Code, ANSI/NFPA 72 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Printed information describing proper installation, operation, testing, maintenence, evacuation planning, and repair service must be provided with this equipment. Warning - Owners Instruction Notice: Not to be removed by anyone except occupant. Suitable for the following applications: 1) Household Burglar Alarm System Units, Grade A, 2) Household Fire Warning System Units, 3) Police Station Connect, Grade A; Local, Grade A Mercantile. Model D8108A Attack Resistant Enclosure and a UL Listed local sounding device are required, 4) Central Station, Grade C; Central Station, Grade B when installed with a UL Listed sounding device, and Encrypted Line Security when communicating via a network, 5) Proprietary Burglar Alarm Units, Grade A. Install the ICP-EZM2 according to the Easy Series Installer Guide (P/N: F01U025147). Warning: This unit includes an alarm verification feature that delays the system alarm signal from the indicated circuits. The total delay (control unit plus smoke detectors) must not exceed 60 sec. Do not connect any other smoke detector to these circuits unless approved by the local Authority Having Jurisdiction (AHJ).
Control Unit (Delay-sec)
Twisted pair wire (recommended)
9 (22.86) 3 m (10 ft) minimum distance from control center to control panel.
Auxiliary Power 12 VDC, 1 A maximum. Subtract 110 mA for each control center connected to the system.
Powered sensor point suitable for two-wire smoke detectors. 2.2 k W resistor (P/N: 25899) required at End-of-Line. For compatible smoke detectors, refer to the Easy Series Intrusion Control Panel Smoke Detector Compatibility List (P/N: F01U004853). UL Control Panel Compatibility Identifier = B. This loop also supports four-wire smoke detectors, such as the Bosch Security Systems D273TH or F220 Series. This loop can also be used as a supervised point.
Delay-sec
Test posts for phone set connection
ICP-EZM2 Control Panel Current Draw: 85 mA standby; 160 mA alarm (all outputs activated) Voltage: 12.0 VDC nominal (11.2 VDC to 12.3 VDC)* Total Alarm Power: 1.4 A (AC and battery; intrusion applications only)** Auxiliary Power Current: 1.0 A for all auxiliary devices * Auxiliary power devices 11.2 to 12.3 VDC. The ICP-EZM2 stops processing point faults when the voltage drops below 9.5 VDC. ** With a 7.0 Ah battery, the following current draws apply to all outputs and devices connected to the system: - Up to 170 mA for 24 hr for fire and combined fire/burglary applications - Up to 400 mA for 4 hr for UL burglary applications - Up to 1.2 A for other applications (not investigated by UL)
B GY R
Model
1 40 (a) (a) Use the delay (power-up or start-up) time as marked on the smoke detectors installation wiring diagram, or on the installed smoke detector(s). Control unit delay time + smoke detector delay time = 60 sec.
IUI-EZ1 Control Center Audio Bus (+) Audio Bus (-)
Smoke Detector Circuit (Zone)
Plug-in or Wire-in Power Supply Use a UL Listed 18 V Class 2 Transformer 22 VAC, VA 50/60 Hz (TDC Power, model DA-22-18; 18 VAC, 22 VA), or the ICP-EZPS power supply. Do not connect to a receptacle controlled by a switch.
ICP-EZPS (not investigated by UL) AC Input Voltage: 100 to 240 VAC Line Voltage Frequency: 47 to 63 Hz Maximum Input Current: 0.5 A Power Factor: Approximately 0.65 at full load
Earth Ground
Jumper (J) Placement Selections = dry contact
= switched ground
= switched 12 V
NOTES: 1. Material: White 60# UL listed paper stock with permanent, pressure sensitive adhesive backing. 2. Print color: Black 3. Corners may have a radius. 4. Border is part of label - must show on finished product. 5. To be supplied individually and in such a manner as to keep them from curling. 6. Dimensions are in inches (centimeters). 7. For adhesive specifications refer to drawing # 22941. 8. Tolerances are +/- .020 (+/- .05). 9. The end user must be able to write on the finished product.
Battery Lead (Red) Battery Lead (Black)
12 VDC Battery Maximum charging current is 1.7 A. Replace every 3 to 5 years. Use a D126 7 AH or D1218 18 AH sealed, lead acid battery for burglary or combination fire and burglary systems. For additional load or standby power, refer to the battery calculation sheet in installation manual (P/N: F01U025147).
System Test Button
Power-limited Wiring All wiring except primary AC power and standby battery is power-limited. Separate primary AC power and standby battery wires from other wires by at least 6.4 mm (¼ in.), and secure to enclosure to prevent movement. Primary AC power and standby battery wiring cannot share the same conduit, conduit fittings, or conduit knockouts with any other wiring. The Class 2, Class 3, and power-limited fire alarm circuits are installed using CL3, CL3R, or CL3P, or substitute cable as permitted by the National Electrical Code, ANSI/NFPA 70. Power-limited fire alarm circuit conductors that extend beyond the cable jacket must be separated a minimum of 6.4 mm (¼ in.), or by non-conductive tubing or by a non-conductive barrier from all other conductors.
Supervised Points (Single EOL) 2.2 kW Resistor (P/N: 47819) required at End-of-Line Point Tamper Wiring (Dual Resistor Supervision)
Tamper contact 2.2 kW alarm resistor Alarm contact
2.2 kW EOL resistor
NAC
NAC
NAC
NAC
Programmable Outputs (PO) 2 to 4 Open-collector outputs. 400 mA (not to exceed the maximum current of the control panel). PO 4 can also be programmed and used as a supervised speaker driver. Connect an approved 8 W speaker. For UL installations, connect a UL Listed bell/audible sounding device with an 85db rating to the supervised output terminal PO 4. Programmable Output (PO) 1 Contact Rating: 2A Jumper installed: Current rating = 1.2 A* *When using the supply power to source or sink from the control panel. Not to exceed the maximum current of the control panel. Refer above for jumper placement selections. Minimum system requirements for classification in accordance with ANSI/SIA CP-01-2000: - UL listed and classified control unit Model ICP-EZM2 Control Panel - At least one UL listed and classified keypad Model ICP-EZ1 Control Center - UL listed local sounding device
P/N: F01U025113B 8/06 © 2006 Bosch Security Systems, Inc.
PROPRIETARY DATA DATA CONTAINED HEREIN SHALL NOT BE USED, DUPLICATED OR DISCLOSED IN WHOLE OR PART OUTSIDE OF BOSCH SECURITY SYSTEMS WITHOUT EXPRESSED WRITTEN PERMISSION OF SAME.
PART NO. F01U025113B BOSCH SECURITY SYSTEMS 130 PERINTON PARKWAY FAIRPORT, NEW YORK, 14450-9199 USA (585) 223 4060 FAX (585) 223 9180
BOSCH
DRAWING TITLE
LBL- ICP-EZM2-EN Wiring Label DATE DRAWN: 8/23/06 DRAWING NUMBER
DRAWN BY: JF4 APPR BY: DMC
BF01U025113 Rev. B
SCALE 1:1 SHEET 1 OF 1