Preview only show first 10 pages with watermark. For full document please download

Eaton 5115rm Brochure

   EMBED


Share

Transcript

Powerware 5115RM Uninterruptible Power System 500-1500 VA high density power protection solution Product Focus Product Snapshot Power Rating: 500-1500 VA Voltage: 220-240 VAC Frequency: 50/60 Hz Configuration: Multi-mount 19" rack, Zero U & wall mount Topology: Line-interactive Features The Powerware 5115 Rack  1U rack conserves valuable rack space Mount UPS is the ideal high-  Unique chassis adapts to rack mount, wall mount, side cabinet (zero U) and bench top applications  ABM™, prolongs battery life by 50% density power protection solution for servers, storage systems, network equipment and other critical devices. The slim design  True sine wave output delivers smooth, continuous power and wide range of installation  Load segments - scheduled shutdown of non-critical load possibilities make the 5115RM  Hot-swappable user replaceable batteries the most versatile UPS available.  Standard USB and RS232 serial ports extend Occupying only 1U of rack communication capacity  X-Slot card communication options  Software Suite bundled Options  ConnectUPS-X Web/SNMP card with in-built switching hub  Relay card height, the 5115 conserves valuable rack space for other critical devices while delivering powerful performance. Unlike other UPSs that use simulated sine wave, the Powerware 5115 Rack Mount provides pure sine wave output during battery operation. As a Typical Applications result, the connected devices  Rack mounted servers continue to receive high quality  Network devices  Storage systems electrical input and operate smoothly even during power outages. In addition, this unique UPS corrects incoming voltage fluctuations to further protect the connected equipment. Technical Specifications POWERWARE 5115 RM Rating Part number Capacity (VA/Watts) Dimensions WxDxH (mm) Weight (kg) Input connection Output connection Operational Nominal input voltage (Vac) Input voltage range Input frequency range Operating frequency Nominal output voltage On utility output voltage regulation On battery output voltage regulation Overload (normal operation) Battery Battery type Recharge time Start-On-Battery User interface LED 500VA 51150500iRM 500/320 15.9 750VA 51150750iRM 750/520 1000VA 51151000iRM 1000/670 440 x 578 x 44 18.8 18.8 IEC320/ 10A 4xIEC320 10A (2 sockets per load segment) 1500VA 51151500iRM 1500/1000 22.0 220/230/240 Vac +20/-20% of nominal 45-65Hz 50/60Hz auto sensing 220/230/240 Vac (user selectable) -10%/+6% of selected nominal Voltage +5% RMS 110% overload, shutdown after 3 minutes 150% overload, shutdown after 3 cycles Sealed, lead-acid maintenance free < 3 hours to 90% useable capacity Allows start of UPS without utility power LED status display; AC Power On, Load Group, Overload, On Battery and General Alarm Indicators 1 x RS232 Serial Port & 1 x USB Port Standard communications Environmental Operating temperature Storage temperature Altitude Audible noise at 1 metre Certification Markings Safety EMC 0ÀC to +40ÀC -15ÀC to +50ÀC < 3000 m < 40dB typical CE/UL/C-Tick EN 50091-1-1 & UL 1778 EN 50091-2, EN6100-3-2, C-Tick Battery Runtimes in minutes Load 200VA/130W 300VA/190W 500VA/320W 600VA/400W 750VA/520W 900VA/600W 1000VA/670W 1200VA/800W 1500VA/1000W 51150500iRM 19 11 5 - 51150750iRM 37 25 13 9 6 - 51151000iRM 41 29 15 12 8 6 5 - 51151500iRM 76 58 28 21 16 11 9 8 5 This guide provides typical application information. Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc. www.poweronaustralia.com.au Power On Australia Pty Ltd | ABN 48 110 752 442 | PH 1300 662 435 | FX 1300 76 24 16 [email protected] Ph: 1300 66 24 35 www.poweronaustralia.com.au