Preview only show first 10 pages with watermark. For full document please download

Eaton 5e

   EMBED


Share

Transcript

www.eaton.lv/UPS Eaton 5E 500/650/850/1100/1500/2000 Important safety instruction - Read before installing product Safety of persons ► The UPS has its own internal power source (the battery). Consequently, the power outlets may be energized even if the UPS is disconnected from the AC-power source. ► Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. ► The UPS must be properly earthed. Measurements are required to ensure that the total leakage current of the UPS and the protected equipment does not exceed 3.5mA by checking their characteristics. ► The battery supplied with the UPS contains small amounts of toxic materials. To avoid accidents, the directives listed below must be observed: - Never burn the battery (risk of explosion). - Do not attempt to open the battery (the electrolyte is dangerous for the eyes and skin). - Comply with all applicable regulations for the disposal of the battery. - Batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high. Precautions must be taken for all handing: remove watches, rings, bracelets and any other metal objects, use tools with insulated handles. Product safety ► ► ► ► ► ► ► ► ► The UPS connection instructions and operation described in the manual must be followed in the indicated order. UPS must be connected to a nearby wall outlet that is easily accessible. The UPS can be disconnected from the AC-power source by removing the power cord. Check that the indications on the rating plate correspond to your AC-power system and to the actual electrical consumption of all the equipment to be connected to the UPS. Never install the UPS near liquids or in an excessively damp environment Never let a foreign body penetrate inside the UPS. Never block the ventilation grates of the UPS. Never expose the UPS to direct sunlight or source of heat. If the UPS must be stored prior to installation, storage must be in a dry place. The admissible storage temperature range is –10°C to +40°C. Special precautions ► ► ► Once installed and connected to the AC power source for the first time, the battery will start to charge. Full charging to obtain the rated battery backup time requires at least 8 hours. Before and after the installation, if the UPS remains de-energized for a long period, the UPS must be energized for a period of 24 hours, at least once every 6 months (for a normal storage temperature less than 25°C). This charges the battery, thus avoiding possible irreversible damage. During the replacement of the battery module, it is imperative to use the same type and number of element previously mounted in the UPS, in order to maintain an identical level of performance and safety. In case of doubt, don’t hesitate to contact our after sales department (for more information, refer to the web site www.eaton.eu). Svarīgi drošības norādījumi — izlasiet pirms izstrādājuma instalēšanas Personu drošība ► UPS ir pašam savs iekšējais barošanas avots (akumulators). Tādējādi kontaktligzdām var tikt pievadīts spriegums pat tad, ja UPS ir atvienots no maiņstrāvas avota. ► UPS iekšienē ir bīstams sprieguma līmenis. To drīkst atvērt tikai kvalificēti apkopes speciālisti. ► UPS ir jānodrošina atbilstošs zemējums. Lai pārliecinātos, ka kopējā UPS un aizsargātā aprīkojuma noplūdes strāva nepārsniedz 3,5 mA, jāveic mērījumi, pārbaudot to raksturlielumus. ► Kopā ar UPS piegādātais akumulators satur nelielu daudzumu toksisku materiālu. Lai nepieļautu nelaimes gadījumus, jāievēro tālāk minētie norādījumi. - Nekad nededziniet akumulatoru (sprādziena risks). - Nekad nemēģiniet atvērt akumulatoru (elektrolīts ir bīstams acīm un ādai). - Utilizējot akumulatoru, ievērojiet visus piemērojamos noteikumus. - Akumulatori rada apdraudējumu (elektriskās strāvas triecieni, apdegumi). Īsslēguma strāva var būt ļoti augsta. Veicot jebkādas darbības, jāievēro drošības pasākumi: jānoņem pulksteņi, gredzeni, aproces un citi metāla priekšmeti; jāizmanto instrumenti ar izolētiem rokturiem. Izstrādājuma drošība ► ► ► ► ► ► ► ► ► Rokasgrāmatā sniegtie UPS pievienošanas un lietošanas norādījumi ir jāizpilda norādītajā secībā. UPS ir jāpieslēdz tuvumā esošai, viegli pieejamai sienas kontaktligzdai. UPS var atvienot no maiņstrāvas avota, atvienojot barošanas vadu. Pārbaudiet, vai norādījumi uz tehnisko pamatdatu plāksnes atbilst jūsu maiņstrāvas sistēmai un faktiskajam pie UPS pieslēdzamā aprīkojuma elektrības patēriņam. Nekad neuzstādiet UPS šķidrumu tuvumā vai īpaši mitros apstākļos. Nekad nepieļaujiet svešķermeņu iekļūšanu UPS. Nekad nenobloķējiet UPS ventilācijas sprauslas. Nekad nepakļaujiet UPS tiešiem saules stariem vai siltuma avotiem. Ja UPS pirms uzstādīšanas ir jāglabā, tas jātur sausā vietā. Pieļaujamā glabāšanas temperatūra ir no –10 °C līdz +40 °C. Īpaši drošības pasākumi ► ► ► Pirmo reizi uzstādot un pieslēdzot maiņstrāvas avotam, sākas akumulatora uzlāde. Lai pilnībā uzlādētu akumulatoru un nodrošinātu nominālo akumulatora rezerves laiku, nepieciešamas vismaz 8 stundas. Ja pirms un pēc uzstādīšanas UPS tiek atvienots no sprieguma uz ilgu laiku, tas jāpieslēdz spriegumam uz 24 stundām vismaz reizi 6 mēnešos (normālā glabāšanas temperatūrā, kas zemāka par 25 °C). Tādējādi akumulators tiek uzlādēts, novēršot iespējamus neatgriezeniskus bojājumus. Akumulatora moduļa nomaiņas laikā ir svarīgi izmantot tā paša veida elementu ar tādu pašu numuru, kā iepriekš uzstādīts UPS, lai nodrošinātu identisku veiktspējas un drošības līmeni. Šaubu gadījumā sazinieties ar pēcpārdošanas nodaļu (papildinformāciju skatiet tīmekļa vietnē www.eaton.lv/UPS). QUICKSTART 6 stundas SYSTEM DESCRIPTION 1. Power management port only on USB models 2. ON/OFF button Barošanas pārvaldības ports tikai USB modeļiem IESLĒGŠANAS/IZSLĒGŠANAS poga 5E500/650/850 1. 220/230/240V AC 3. Internet line protection only for USB models Interneta līnijas aizsardzība tikai USB modeļiem 2. 4 Outlets with battery backup 4 ligzdas ar akumulatora rezervi 5E650DIN/850DIN 1. 220/230/240V AC 2. 3 outlets with battery backup (1 Schuko + 2 IEC) 3. Internet/modem line protection only for USB models Interneta/modema līnijas aizsardzība tikai USB modeļiem 3 ligzdas ar akumulatora rezervi (1 Schuko + 2 IEC) 5E1100/1500/2000 1. 220/230/240V AC 3. Internet line protection Interneta līnijas aizsardzība 2. 6 Outlets with battery backup 6 ligzdas ar akumulatora rezervi 4. Fan TROUBLE SHOOTING Symptom No LED display on the front panel. Possible Cause 1. Battery weak. 2. Battery defect. 3. Power switch is not pressed. Alarm buzzer beeps continuously when AC Overload of the UPS. supply is normal. When power failure, back-up time is 1. Overload of the UPS. shorten. 2. Battery voltage is too low. 3. Battery defect or aging Remedy 1. Charge battery up to 8 hours. 2. Replace with the same type of battery. 3. Press the power switch again. Verify that the load matches the UPS capability specified in the spec. 1. Remove some noncritical load. 2. Charge battery 8 hours or more. 3. Replace with the same type of battery. Mains normal but LED is flashing. Power cord is loose. Reconnect the power cord properly. Problēma Priekšējā panelī nedeg LED. Iespējamais cēlonis 1. Akumulators gandrīz tukšs. 2. Akumulatora bojājums. 3. Barošanas slēdzis nav nospiests. UPS pārslodze. 1. UPS pārslodze. 2. Akumulatora spriegums ir pārāk zems. 3. Akumulatora bojājums vai novecošanās. Risinājums 1. Uzlādējiet akumulatoru līdz 8 stundām. 2. Nomainiet ar tāda paša veida akumulatoru. 3. Vēlreiz nospiediet barošanas slēdzi. Pārbaudiet, vai slodze atbilst specifikācijā norādītajai UPS kapacitātei. 1. Atvienojiet mazāk svarīgu slodzi. 2. Uzlādējiet akumulatoru 8 stundas vai ilgāk. 3. Nomainiet ar tāda paša veida akumulatoru. Barošanas vads ir vaļīgs. Cieši pievienojiet barošanas vadu. Kad maiņstrāvas padeve ir normāla, trauksmes signāls skan nepārtraukti. Elektroapgādes traucējumu gadījumā rezerves laiks ir īsāks. Tīkls normas robežās, bet LED mirgo. SPECIFICATIONS MODEL CAPACITY VA/W INPUT Input voltage range 5E500i 500VA/ 300W 5E650i 650VA/ 360W 5E650iUSB 650VA/ 360W 170V-264V 50Hz or 60Hz +/-1 Hz Output Waveform Modified Sine wave (1)12V 4.5Ah (1)12V 7Ah (1)12V 7Ah Recharge Time USB TRANSFER TIME Typical INDICATOR AC Mode Battery Mode SURGE SUPPRESSION RJ-11 protection PROTECTION PHYSICAL WEIGHT ENVIRONMENT BACK UP TIME (2)12V 9Ah (2)12V 9Ah Yes 2-6ms typical, 10ms max. 4-8ms typical, 10ms max. Green LED lighting Green LED Flashing No Yes Sounding every 10 seconds Sounding every 1second Overload Sounding every 0.5 second Sounding every 2 seconds Continuously sounding Discharge, overcharge, and overload protection 148*100*288 3.7Kg 4.6Kg 4.6Kg 180*133*330 5.1Kg 9.3Kg 10.5Kg 10.5Kg 0°C - 40°C Noise Level Altitude For a 100W load (2)12V 7Ah No Low Battery Battery replace Fault Full Protection Dimensions H*W*D Net Weight Operating Environment (1)12V 9Ah 6 hours to 90% after complete discharge Backup Mode AUDIBLE ALARM 5E2000iUSB 2000VA/ 1200W +/-10% Frequency Regulation (Bat. Mode) COMMUNICATION 5E1500iUSB 1500VA/ 900W 230V Frequency Battery Type BATTERY 5E1100iUSB 1100VA/ 660W 170V-280V Output on battery Voltage Regulation (Bat. Mode) OUTPUT 5E850iUSB 850VA/ 480W Less than 40dB Less than 45dB The maximum operating altitude must not exceed 2000m 7min 16min 16min 20min 30min 40min 45min MODELIS IETILPĪBA VA/W IEVADE Ievades sprieguma diapazons 5E500i 500 VA/ 300 W 5E650i 650 VA/ 360 W 5E650iUSB 650 VA/ 360 W +/–10% 50 Hz vai 60 Hz +/–1 Hz Izejas līknes Modificēts sinusoidālais vilnis (1)12 V 4,5 Ah (1)12 V 7 Ah Uzlādes laiks SAZIŅA USB PĀRSŪTĪŠANAS LAIKS Tipiski INDIKATORS Maiņstrāvas režīms Akumulatora režīms PĀRSPRIEGUM A DZĒŠANA RJ-11 aizsardzība (1)12 V 7 Ah 2–6 ms tipiski, 10 ms maks. Izmēri A*P*D SVARS Neto svars Nē Jā Atskan ik pēc 10 sekundēm Atskan ik pēc 1 sekundes Atskan ik pēc 0,5 sekundēm Atskan ik pēc 2 sekundēm Skan nepārtraukti Aizsardzība pret izlādi, pārlādi un pārslodzi 148*100*288 3,7 kg 4,6 kg 4,6 kg Trokšņa līmenis Pie 100 W slodzes 180*133*330 5,1 kg 9,3 kg 10,5 kg 10,5 kg 0–40 °C Mazāks nekā 40 dB Augstums REZERVES LAIKS 4–8 ms tipiski, 10 ms maks. LED mirgo zaļā krāsā Ekspluatācijas vide VIDE (2)12 V 9 Ah LED deg zaļā krāsā Akumulatora nomaiņa Kļūme FIZISKIE DATI (2)12 V 9 Ah Jā Pārslodze Pilna aizsardzība (2)12 V 7 Ah 6 stundas līdz 90% pēc pilnīgas izlādēšanās Zems akumulatora uzlādes līmenis AIZSARDZĪBA (1)12 V 9 Ah Nē Rezerves režīms SKAŅAS SIGNĀLS 5E2000iUSB 2000 VA/ 1200 W 230 V Biežums Akumulatora veids 5E1500iUSB 1500 VA/ 900 W 170V–280V Frekvences regulēšana (akum. režīms) AKUMULATORS 5E1100iUSB 1100 VA/ 660 W 170V–264V Izvade uz akumulatoru Sprieguma regulēšana (akum. režīms) IZVADE 5E850iUSB 850 VA/ 480 W Mazāks nekā 45 dB Maksimālais ekspluatācijas augstums ir 2000 m 7 min 16 min 16 min 20 min Kontaktpersona (CE atbilstība): Eaton Electric SIA Zemitānu iela 2b, Rīga + 371 678 444 35 [email protected] 30 min 40 min 45 min