Preview only show first 10 pages with watermark. For full document please download

Eaton-switched-epdu-pw103sw0u152-technical

   EMBED


Share

Transcript

ECO No. A B NONE 8534 C 8793 DR REVISION ENGINEERING RELEASE UPDATE SILKSCREEN CK JDS JDS DATE AP AP 06/01/07 02/11/08 DK 10 FEB 10 UPDATE BORDER, LOGO, NOTES, GND SCREWJ.O. ON I SECTION 2 OFF O SECTION 1 C/B 2 J30 SWITCH SENSOR TEMP J29 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 J15 J16 TOTAL SYSTEM CURRENT DRAW IN J27 ON I OUT STRAPPING 9.00 14.28 1.89 3.71 2.00 66.00 J27 TEMP J29 RESET OFF O ON I C/B 2 SECTION 1 SENSOR AMPS IN J30 SWITCH OFF O OUT STRAPPING OFF O NET J25 ON I J28 SERIAL J26 C/B 1 1:1 SCALE OFF O NET J25 OFF O J28 SERIAL 26 C/B 1 L5-30 1:2 SCALE LTR J1 NOTES: 1. RACK MOUNTED 18AWG STEEL CHASSIS, BLACK MEDIUM TEXTURE 66.00" LENGTH (70" WITH BRACKETS) 2.00" WIDTH 1.89" DEPTH MOUNTING HARDWARE KIT INCLUDED (SUB-HRDWARE-046) 2. INPUT: 120 VAC 24A SINGLE PHASE, 50/60 Hz. POWER CABLE: 9 FT. 10/3 SOOW CABLE WITH NEMA L5-30 PLUG 3. OUTPUT: 120 VAC 12A, SINGLE PHASE 50/60Hz. AT 16 INDIVIDUALLY CONTROLLED NEMA 5-15 OUTLETS J1 - J16 24A MAX TOTAL C/B 1: SECTION 1 (J1-J8), 12A MAX. C/B 2: SECTION 2 (J9-J16), 12A MAX. 4. BREAKERS: TWO 1-POLE 15A UL LISTED BREAKERS 5. SPIKE/SURGE PROTECTION: LINE TO NEUTRAL 6. FILTER: NONE 7. CURRENT MONITOR: 30 AMPS MAX TRUE RMS CURRENT METER RESOLUTION: ± 1 AMP LOCAL LED DISPLAY REMOTE MONITORING VIA ETHERNET OR SERIAL CONNECTION 8. STRAPPING: CONNECT UP TO 23 ADDITIONAL IPV SERIES POWER CONTROLLERS USING J27 & J28 CONNECTORS. SUB-HRDWARE-046 TOOL-LESS 9. REMOTE CONTROL: J25: RJ45 ETHERNET PORT; 7 FT. CAT-5 CABLE INCLUDED J26: RJ12 RS-232 SERIAL PORT; 6 FT. CABLE TO DB9 INCLUDED 10. CONTROL INTERFACES: SERIAL TEXT MENU VIA TERMINAL SOFTWARE TELNET TEXT MENU VIA TERMINAL SOFTWARE WEB BROWSER GRAPHICAL INTERFACE SNMP READ/WRITE 11. SENSOR INTERFACES: (OPTIONAL SENSORS REQUIRED) TEMP INTERFACE: MONITORS TEMPERATURE AND HUMIDITY SWITCH INTERFACE: MONITORS 3 SEPARATE CONTACT CLOSURES 12. INDICATOR LIGHTS: 18 16 GREEN LIGHTS, INDIVIDUAL OUTLET POWER 2 BLUE LIGHTS, ON WHEN CORRESPONDING BREAKER IS ON EATON APPROVAL DATE 13. US/C ETL LISTED ITE EQUIPMENT EN 60950-1 14. RoHS COMPLIANT PRODUCT PER DIRECTIVE 2002/95/EC WITH APPLICABLE EXEMPTIONS 9650 Jeronimo Road, Irvine, California 92618 Phone (949) 452-9500 THE INFORMATION AND DESIGN DISCLOSED HEREIN WAS ORIGINATED DIMENSIONS IN INCHES TOLERANCES: BY AND IS THE PROPERTY OF EATON CORPORATION. EATON DECIMALS ANGLES CORPORATION RESERVES ALL PATENT, PROPRIETARY, DESIGN, .XX ± 0.5° ±.020 MANUFACTURING, REPRODUCTION, USE AND SALE RIGHTS THERETO, UNLESS .XXX AND TO ANY ARTICLE DISCLOSED THEREIN, EXCEPT TO THE EXTENT OTHERWISE RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THE FOREGOING DOES ±.010 SPECIFIED 2010 EATON CORP NOT APPLY TO VENDOR PROPRIETARY PARTS. COPYRIGHT CAGE CODE 31795 IPV70C5-EP1-09L DRAWN BY: J. SMITH SCALE .50 www.ePDU.com ENGINEERING DRAWING TITLE SIZE E ASSY 3562 DWG FILENAME: IPV70C5_EP1_09L_3562C_ME.DWG SHEET DWG NO. REV 1 OF 1 IPV70C5_EP1_09L_3562C_ME C