DATA SHEET Flexible 50 Ω coaxial cable
Kabelwerk
EUPEN AG
EC200 - Rev. 3 - 23.06.11
cable
EC 200 Flexible 50 Ohms low loss coaxial cable
CHARACTERISTICS Construction
Electrical characteristics
Inner conductor Material Construction Diameter (mm) Dielectric Material Diameter (mm)
copper wire 1.05
gas-injected cellular polyethylene 2.95
Outer conductor luminium tape, bonded to the dielectric Tape Diameter over tape (mm) 3.05 Braid tinned copper braid Diameter over braid (mm) 3.7 Outer sheath Material Thickness (mm) Diameter (mm)
black polyethylene 0.65 5.0
Mechanical characteristics Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Weight (kg/km)
2.5 5 11 -70 to +85 °C -40 to +60 °C -55 to +85 °C 32
[1] The attenuation can be approximated by the formula: ( f [ MHz ]) A
f [ MHz ] B f [ MHz ]
A = 1.0416 B = 0.00159
(dB/100m)
Characteristic impedance Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (µH/m) DC-resistance at 20°C - inner conductor ( /km) - outer conductor ( /km) RF peak voltage (kV ) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M .km) Screening attenuation (dB ) Attenuation[1] and power rating Attenuation at 20°C [2]
Frequency
(MHz) 10 20 30 80 100 150 200 300 400 450 500 600 700 800 894 960 1000 1500 1700 1800 1880 2000 2170 2200 2300 2400 2500 3000
(dB/100m) 3.31 4.69 5.75 9.44 10.58 13.00 15.05 18.52 21.47 22.81 24.09 26.47 28.67 30.73 32.57 33.80 34.53 42.73 45.65 47.05 48.15 49.76 51.97 52.35 53.61 54.84 56.06 61.82
50 ± 2 80.5 83 0.201 19.9 12.1 0.4 1.6 39 >> 5000 > 90 Mean power rating [3]
(kW) 1.62 1.14 0.93 0.57 0.51 0.41 0.36 0.29 0.25 0.23 0.22 0.20 0.19 0.17 0.16 0.16 0.15 0.13 0.12 0.11 0.11 0.11 0.10 0.10 0.10 0.10 0.10 0.09
[2] Nominal values [3] Ambient temperature = 40°C; temperature of inner conductor = 100°C; VSWR = 1.0; no solar loading
DATA SHEET Flexible 50 Ω coaxial cable
Kabelwerk
EUPEN AG
EC400 Plus - Rev. 2 - 23.06.11
cable
EC 400 Plus Flexible 50 Ohms low loss coaxial cable
CHARACTERISTICS Construction Inner conductor Material Construction Diameter (mm) Dielectric Material Diameter (mm)
Electrical characteristics copper clad aluminium wire 2.7
gas-injected cellular polyethylene 7.25
Outer conductor luminium tape, bonded to the dielectric Tape Diameter over tape (mm) 7.35 Braid tinned copper braid Diameter over braid (mm) 8.0 Outer sheath Material Thickness (mm) Diameter (mm)
black polyethylene 1.1 10.2
Mechanical characteristics Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Weight (kg/km)
2.5 5 30 -70 to +85 °C -40 to +60 °C -55 to +85 °C 90
[1] The attenuation can be approximated by the formula: ( f [ MHz ]) A
f [ MHz ] B f [ MHz ]
A = 0.402 B = 0.00082
(dB/100m)
Characteristic impedance Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (µH/m) DC-resistance at 20°C - inner conductor ( /km) - outer conductor ( /km) RF peak voltage (kV ) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M .km) Screening attenuation (dB ) Attenuation[1] and power rating Attenuation at 20°C [2]
Frequency
(MHz) 10 20 30 80 100 150 200 300 400 450 500 600 700 800 894 960 1000 1500 1700 1800 1880 2000 2170 2200 2300 2400 2500 3000
(dB/100m) 1.3 1.8 2.2 3.7 4.1 5.1 5.9 7.2 8.4 8.9 9.4 10.3 11.2 12.0 12.8 13.2 13.5 16.8 18.0 18.5 19.0 19.6 20.5 20.7 21.2 21.7 22.2 24.5
50 ± 2 78.5 85 0.196 4.56 6.4 1.0 10 16 >> 5000 > 90 Mean power rating [3]
(kW) 5.05 3.56 2.90 1.76 1.57 1.28 1.10 0.90 0.77 0.73 0.69 0.62 0.58 0.54 0.51 0.49 0.48 0.38 0.36 0.35 0.34 0.33 0.31 0.31 0.31 0.30 0.29 0.26
[2] Nominal values [3] Ambient temperature = 40°C; temperature of inner conductor = 100°C; VSWR = 1.0; no solar loading
DATA SHEET Flexible 50 Ω coaxial cable
Kabelwerk
EUPEN AG
EC600 - Rev. 2 - 23.06.11
cable
EC 600 Flexible 50 Ohms low loss coaxial cable
CHARACTERISTICS Construction Inner conductor Material Construction Diameter (mm) Dielectric Material Diameter (mm)
Electrical characteristics copper clad aluminium wire 4.47
gas-injected cellular polyethylene 11.56
Outer conductor Tape Diameter over tape (mm) Braid Diameter over braid (mm) Outer sheath Material Thickness (mm) Diameter (mm)
aluminium tape 11.7 tinned copper braid 12.3
black polyethylene 1.35 15.0
Mechanical characteristics Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) Maximum pulling strength (daN) Recommended temperature range - Storage - Installation - Operation Weight (kg/km)
8 15 50 -70 to +85 °C -40 to +60 °C -55 to +85 °C 175
[1] The attenuation can be approximated by the formula: ( f [ MHz ]) A
f [ MHz ] B f [ MHz ]
A = 0.246 B = 0.00065
(dB/100m)
Characteristic impedance Nominal capacity (pF/m) Relative propagation velocity (%) Inductance (µH/m) DC-resistance at 20°C - inner conductor ( /km) - outer conductor ( /km) RF peak voltage (kV ) RF peak power (kW) Cut-off-frequency (GHz) Insulation resistance (M .km) Screening attenuation (dB ) Attenuation[1] and power rating Attenuation at 20°C [2]
Frequency
(MHz) 10 20 30 80 100 150 200 300 400 450 500 600 700 800 894 960 1000 1500 1700 1800 1880 2000 2170 2200 2300 2400 2500 3000
(dB/100m) 0.8 1.1 1.4 2.3 2.5 3.1 3.6 4.5 5.2 5.5 5.8 6.4 7.0 7.5 7.9 8.3 8.4 10.5 11.3 11.6 11.9 12.3 12.9 13.0 13.3 13.6 13.9 15.4
50 ± 2 76.7 87 0.191 1.65 4.4 1.6 25.6 10 >> 5000 > 90 Mean power rating [3]
(kW) 9.74 6.87 5.59 3.39 3.03 2.46 2.12 1.72 1.48 1.39 1.31 1.19 1.10 1.02 0.96 0.93 0.91 0.73 0.68 0.66 0.64 0.62 0.59 0.59 0.57 0.56 0.55 0.50
[2] Nominal values [3] Ambient temperature = 40°C; temperature of inner conductor = 100°C; VSWR = 1.0; no solar loading
DATA SHEET Flexible 50 Ω coaxial cable
Kabelwerk
EUPEN AG
58RT5(V) - Rev. 1 - 09.01.09
cable
58RT5(V) Flexible 50 Ohms low loss coaxial cable
CHARACTERISTICS Construction
Electrical characteristics
y Inner conductor Material Construction Diameter (mm) y Dielectric Material Diameter (mm)
copper wire 1.05
gas-injected cellular polyethylene 2.95
y Outer conductor Tape Diameter over tape (mm) Braid Diameter over braid (mm)
aluminium tape 3.05 tinned copper braid 3.7
y Outer sheath Material Thickness (mm) Diameter (mm)
Black PE / PVC 0.7 5.0
Mechanical characteristics y Minimum bending radius a) single bending (cm) b) 15 repeated bends (cm) y Maximum pulling strength (daN) y Recommended temperature range - Storage - Installation - Operation y Weight (kg/km)
2.5 5 7 -70 to +85 °C -40 to +60 °C -55 to +85 °C 25 (PE) / 30 (PVC)
[1] The attenuation can be approximated by the formula: α ( f [ M H] )z= A ⋅
f [ M H] z+ B ⋅ f [ M H] + z C
A = 0.86 B = 0.006244 C = 1.417
(dB/100m)
y Characteristic impedance (Ω) y Nominal capacity (pF/m) y Relative propagation velocity (%) y Inductance (µH/m) y DC-resistance at 20°C - inner conductor ( Ω /km) - outer conductor ( Ω /km) y RF peak voltage (kV ) y RF peak power (kW) y Cut-off-frequency (GHz) y Insulation resistance (M Ω .km) y Screening attenuation (dB ) y Attenuation[1] and power rating Attenuation at 20°C [2]
Frequency
(MHz) 10 20 30 80 100 150 200 300 400 450 500 600 700 800 894 960 1000 1500 1700 1800 1880 2000 2170 2200 2300 2400 2500 3000
(dB/100m) 4.20 5.39 6.31 9.61 10.64 12.89 14.83 18.19 21.11 22.47 23.77 26.23 28.54 30.74 32.71 34.06 34.86 44.09 47.49 49.14 50.44 52.37 55.03 55.49 57.02 58.53 60.03 67.25
50 ± 2 82 82 0.203 19.9 28.5 0.4 1.6 39 >> 5000 > 75 Mean power rating [3]
(kW) 1.92 1.35 1.09 0.65 0.58 0.47 0.40 0.32 0.27 0.25 0.24 0.22 0.20 0.18 0.17 0.16 0.16 0.13 0.12 0.11 0.11 0.10 0.10 0.10 0.10 0.09 0.09 0.08
[2] Nominal values [3] Ambient temperature = 40°C; temperature of inner conductor = 100°C; VSWR = 1.0; no solar loading
DATA SHEET RG coaxial cable
Kabelwerk RG 213/U - Rev. 1 - 20.03.07
EUPEN AG cable
RG 213/U
INNER CONDUCTOR Material Construction Diameter DIELECTRIC Material Diameter OUTER CONDUCTOR Material Construction Diameter over outer conductor OUTER SHEATH Material Overall diameter ELECTRICAL CHARACTERISTICS Characteristic impedance Capacity Relative propagation velocity (velocity ratio) DC-resistance of inner conductor DC-resistance of outer conductor Longitudinal attenuation at 20°C
Units
Nominal
mm
copper wire 7 x 0.75 mm 2.25
mm
solid polyethylene 7.25
mm
copper wires single braid 8.0
mm
black PVC 10.3
Ω
a= b= 5 MHz 25 MHz 50 MHz 145 MHz 200 MHz 300 MHz 435 MHz 900 MHz 1250 MHz 1500 MHz 1700 MHz 1800 MHz 2200 MHz 2400 MHz 2500 MHz
pF/m % Ω /km Ω /km
50 +/- 2 100 66 6 4.5
dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m
0.616 0.00492 1.40 3.20 4.60 8.13 9.70 12.15 14.99 22.91 27.93 31.24 33.76 34.99 39.72 41.99 43.10
cm
5
MECHANICAL CHARACTERISTICS Bending radius - Minimum ( 1 x )
DATA SHEET RG coaxial cable
Kabelwerk RG 214/U - Rev. 1 - 20.03.07
EUPEN AG cable
RG 214/U
INNER CONDUCTOR Material Construction Diameter DIELECTRIC Material Diameter OUTER CONDUCTOR Material Construction Diameter over outer conductor OUTER SHEATH Material Overall diameter ELECTRICAL CHARACTERISTICS Characteristic impedance Capacity Relative propagation velocity (velocity ratio) DC-resistance of inner conductor DC-resistance of outer conductor Longitudinal attenuation at 20°C
Units
Nominal
mm
silver-covered copper wire 7 x 0,75 mm 2.25
mm
solid polyethylene 7.25
mm
silver-covered copper wire double braid 8.6
mm
black PVC 10.8
Ω
a= b= 5 MHz 25 MHz 50 MHz 145 MHz 200 MHz 300 MHz 435 MHz 900 MHz 1250 MHz 1500 MHz 1700 MHz 1800 MHz 2200 MHz 2400 MHz 2500 MHz
pF/m % Ω /km Ω /km
50 +/- 2 100 66 6 3.1
dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m
0.639 0.00604 1.46 3.35 4.82 8.57 10.24 12.88 15.95 24.61 30.14 33.81 36.61 37.98 43.26 45.80 47.05
cm
5
MECHANICAL CHARACTERISTICS Bending radius - Minimum ( 1 x )
DATA SHEET RG coaxial cable
Kabelwerk RG 223/U - Rev. 1 - 14.06.01
EUPEN AG cable
RG 223/U
INNER CONDUCTOR Material Construction Diameter DIELECTRIC Material Diameter OUTER CONDUCTOR Material Construction Diameter over outer conductor OUTER SHEATH Material Thickness Minimum thickness at any point Overall diameter ELECTRICAL CHARACTERISTICS Characteristic impedance Capacity Relative propagation velocity (velocity ratio) DC-resistance of inner conductor DC-resistance of outer conductor Longitudinal attenuation at 20°C
Units
Nominal
mm
silver-covered copper wire 1x 0.89
mm
solid polyethylene 2.95
mm
silver-covered copper wire double braid 4.0
mm mm mm
brown PVC 0.5 0.41 5
Ω
a= b= 5 MHz 25 MHz 50 MHz 145 MHz 200 MHz 300 MHz 435 MHz 900 MHz 1250 MHz 1500 MHz 1700 MHz 1800 MHz 2200 MHz 2400 MHz 2500 MHz
pF/m % Ω /km Ω /km
50 +/- 2 101 66 28 7
dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m
1.249 0.00722 2.83 6.43 9.19 16.09 19.11 23.80 29.19 43.97 53.18 59.20 63.77 65.99 74.47 78.52 80.50
cm
2
MECHANICAL CHARACTERISTICS Bending radius - Minimum ( 1 x )