Preview only show first 10 pages with watermark. For full document please download

Eclips T120-mdp Cut Sheet

   EMBED


Share

Transcript

TMD Low Voltage Surge Protection Device The Eclipse MD series of hybrid TVSS devices are designed with silicone avalanche diodes (SAD) and metal oxide varistors (MOV) to protect sensitive electronic equipment by clamping over-voltage energy pulses and discharging them to ground. This unique design along with the hybrid electronics will Device (SPD) that is truly scalable and provides real solutions. Standard Features: • • • • • • Hybrid electronics SAD and GDT Single point ground 12 AWG green ground strap Available voltage 5v,12v, 24v, 48v,70v, 90v, 120v Polycarbonate plastic case AF-312 Removable terminal connection together that maintains system integrity managing ground planes and structured wiring for service and maintenance. The design features slide together modules and provides panel screw mount, snap track or Din rail mounting options. Coupled with pluggable screw terminals for easy replacement and servicing. Transient Voltage Surge Suppressors (TVSS) must have a managed ground bus that features a single point of ground to ensure ideal conditions. This allows you to maintain system integrity inspection and proper maintenance against electrical transients introduced to sensitive low voltage electronics. providing protection against nuisance alarm and preventable system failure and ensure that your SPD utilizes proper ground path. • din rail • snap track • panel mount (screw) Ground Strap: UL listed 12 gauge stranded (65/30) AWM1015 wire green jacket ground strap. 10 inches long with a crimped on #10 ring lug connector for proper ground termination. How it works: In most instances the SAD does the majority of the work. The SAD clamps closer to the “working” voltage to provide the highest level of protection of the device. The SAD does not degrade until the diode exceeds its rated value. The SAD can manage daily voltage pulses over and over with no degrade of component. MOV can withstand greater peak energy. When the energy exceeds the capacity of the SAD the MOV provides protection against larger and more sustained energy pulses. MOVs are susceptible to degrade every time they clamp. . NFPA ® Space Age Electronics, inc. www.1SAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Made In U.S.A - Uses UL Recognized Components Space Age Electronics, Inc. ED00543 LT10532 2007 Rev.1 1/2 Transient Voltage surge protection devices will be UL 497A or B listed device Eclips TMD or TMDP series. each unit is The device will employ a single ground bus with single point of ground termination and a 12AWG green ground strap with lug ring conector. All electronics are encased in a ABS polycarbonate type AF-312 enclosure that protects the electronics. Each device will have pluggable terminal connectors rated from 12-26 AWG. Each device is scalable and interlock with other like devices. Mounting option are direct screw in, snap track or standard din rail mounting. Dimensions: Typical applications include: Fire/Life safety, Video Surveillance, access Control, Voice/Data and Building Automations, gate access, IP and networks, MD Device Series Voltage: Dissipation (J): Capacitance: MCOV: T05 6v 25j 11,133pF 6v (Max current operating Voltage) Clamping Volts: 9v Maximum Surge Current: Clamping response: Circuit protected: Current Limiting: Max Continuous Current: T12 17v 32j T24 30v 40j T48 60v 80j T70 95v 132j T90 115v 160j T120 130v 212j 9,133pF 7,433pF 3,633pF 2,033pF 1,733pF 108v 144v 17v 34v 65v 95v 122v 168v 14.4v 28.8v 57.6v 84v Interlocking Guides 1,333pF Connection type: Termination rating: Installation: Operating Temp: Max humidity: Weight: 5v thru 24v 4000A 48v thru 120v 18,000A <1Pico Second 2 Circuits 4 wires TMDP- Yes | TMD – No TMDP -150mA | TMD – 5A Plugable Connectors 1.6” Screw terminal 12AWG – 26AWG Series Device 45C/113F 85% 2.08Oz 3.1” Mounting Options: Wiring Diagrams: Wire 1 Wire 2 S und Gro Jumper Snap Track Mount und Gro Jumpers EOLR Wire 2 Wire 1 To E a rth Wire 2 Jumper Single Circuit Double Protection Class A rth Wire 1 Wire 1 Wire 1 Wire 2 S und Gro Class B Circuit 2 Circuit 1 { { To E a To E a Wire 2 Wire 1 rth Wire 2 Wire 1 Wire 2 To E a EOLR Wire 2 Wire 1 .92” rth Wire 2 Wire 1 Wire 1 Wire 2 Wire 2 Wire 1 Wire 1 Wire 2 } } Circuit 1 35mm Din-Rail Mount Circuit 2 und Gro Two Circuits Screw Mount Ordering Information: Model No. Space Age Electronics, inc. www.1SAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Description Model No. Description T05-MD 5v T05-MDP 5v Current Limiting T12-MD 12v T12-MDP 12v Current Limiting T24-MD 24v T24-MDP 24v Current Limiting T48-MD 48v T48-MDP 48v Current Limiting T70-MD T90-MD T120-MD 70v 90v 120v T70-MDP 70v Current Limiting T90-MDP 90v Current Limiting T120-MDP1 20v Current Limiting This document is subject to change without notice, seeAge doc #Electronics, ED0479 for legal Space Inc.disclaimer 2007 ED00543 LT10532 Rev.1 2/2