Eclipse Ratioair Burners Model Ra2000 Data 115-11 11/12/2008

   EMBED


Share

Transcript

Data 115-11 11/12/2008 Eclipse RatioAir Burners Model RA2000 Version 1 Parameter Specifications Maximum Input, BTU/hr (kW) at Neutral Chamber Conditions (Natural Gas) 20,400,000 (5970) Minimum Input, BTU/hr (kW) 350,000 (100) Lower inputs may be achieved, contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 30 to 60 (75 to 150) Fuel pressure at Ratio Regulator Inlet. High Fire Flame Length, Inches (mm) 160 (4000) Measured from the Outlet End of the Combustor. Maximum Flame Velocity, Ft/s (m/s) 375 (114) Approximately 15% excess air at maximum input. Maximum Chamber Temperature °F, °C Alloy Tube 1750 (950) Block & Holder 2200 (1200) Flame Detection UV scanner only Fuel Natural Gas For other fuels, contact Eclipse. • All information is based on laboratory testing in neutral (0.0" w.c.) chamber with standard combustor design. Different chamber conditions will affect the data. • Maximum inputs are given for the standard combustion air blower without an air filter. • All inputs based upon gross calorific values and standard conditions: 1 atmosphere, 70°F (21°C). • Blower motor service factors greater than 1.0 may be required when firing into negative chamber pressure applications. For specific application questions, contact Eclipse. • Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Control & Operation Zone % Excess Air 1000 100 10 0 5000 10000 15000 20000 4500 6000 Input (x 1000 BTU/hr) 0 1500 3000 Input (kW) Medium Velocity Tube Blower Model 60 Hz, 8D (20" w.c. @ 250,000 scfh, 30hp) Specifications 60 Hz Packaged Blower Parameter "w.c. mbar BTU/hr kW -2.0 -5,0 21,475,000 6288 -1.0 -2,5 20,950,000 6134 0.0 0,0 20,400,000 5973 1.0 2,5 19,840,000 5809 2.0 5,0 19,250,000 5637 Maximum Input vs. Chamber Pressure (Natural Gas) NOX Emission Data 120 NOX emission data is given for: • Ambient Combustion Air ~70°F (20°C) • Less than 1000°F (538°C) firing chamber • Minimal Process Air Velocity • ppm Volume Dry at 3% O2 • Neutral Chamber Pressure 100 NOX ppm 80 40 CO emission is largely influenced by chamber conditions. Contact Eclipse for an estimate of CO emissions on your application. 20 Emissions are influenced by: • Chamber Conditions • Fuel Type • Firing Rate • Ratio Regulator Adjustment • Combustion Air Temperature 60 Natural Gas 0 30 0 5000 0 1500 12.0 10000 15000 20000 3000 4500 6000 Input ( x 1000 BTU/hr) Input (kW) Air ∆P vs. Air Flow (Measured Between Tap C & Chamber While Firing) Fuel Orifice ∆P vs. Input ∆P Measured Between Taps B & D 50 20 37 15 Natural Gas (58 mm orifice) 10 2 6.0 4.0 5 2.0 0 0 0 5000 10000 15000 20000 0 1500 3000 4500 6000 Input (x 1000 BTU/hr) Input (kW) 25 Air ∆P ("w.c.) 15 8.0 Air ∆P (mbar) 20 10.0 Fuel Orifice ∆P ("w.c.) Fuel Orifice ∆P (mbar) 25 M ax A ir ∆P firing into neutral chamber 18.5 "w.c. (46.3 mbar) 10 13 5 0 0 0 50000 100000 150000 200000 250000 0 1600 3200 6400 8000 10000 Air Flow (scfh) Air Flow (Nm /hr) 3 Eclipse Model RA2000, v1, Data 115-11, 11/12/2008 Dimensions Inches (mm) 22.9 (581) 26.3 (668) “A” “D” Filter Only 43.7 (1110) 9.44 (240) “B” Blower Scroll Only 39.5 (1004) 12.75 (324) to Actuator Shaft C L Tap “C” UV Scanner Location 3" N.P.T. or B.S.P. Gas Inlet 1/2" B.S.P. Pilot Option Gas Inlet C L Tap “B” Tap “D” 29.3 (745) 20.5 (512) “C” Blower Scroll Only 41.3 (1049) “E” Filter Only 40.4 (1026) Combustor Exhaust Outlet Diameter: 300mm (11.8") .375 (9.5) 8x .47 (12) 22 (560) 16.1 (410) Alloy Tube (AISI 310) Max. Chamber Temp : 1,750°F (950°C) 20.7 (527) 21.4 (544) Eclipse Model RA2000, v1, Data 115-11, 11/12/2008 3 Offered By: Burnerparts.com 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3881 Fax (804) 236-3882 www.burnerparts.com