Data 110-2 12/17/2009 Eclipse RatioMatic Burners Model RM100 Version 3 Specification Parameter Maximum Input, BTU/hr (kW) Frequency 60 Hz Packaged Burner Note: Contact factory for varying chamber pressures or pressures outside the range -2.0 to 2.0" w.c. (-5,0 to 5,0 mbar) 50 Hz Packaged Blower Minimum Input On-Ratio, BTU/hr (kW) Maximum Chamber Temperature, °F (°C) Flame Detection Fuel "w.c. (mbar) 1,295,00 (379) -2.0 (-5,0) 1,210,000 (354) -1.0 (-2,5) 1,120,000 (328) 0.0 (0,0) 1,020,000 (298) 1.0 (2,5) 915,000 (268) 2.0 (5,0) 1,375,000 (403) -2.0 (-5,0) 1,295,000 (379) -1.0 (-2,5) 1,210,000 (354) 0.0 (0,0) 1,120,000 (328) 1.0 (2,5) 1,020,000 (298) 2.0 (5,0) with high turndown ratio regulator 30,000 (9) with standard ratio regulator 40,000 (12) Main Gas Inlet Pressure, "w.c. (mbar) • Fuel pressure at ratio regulator inlet High Fire Flame Length, inches (mm) • Measured from the outlet end of the combustor BTU/hr (kW) 10 to 20 (25 to 50) Natural Gas 32 (813) Propane / Butane 38 (965) Alloy Tube 1500 (820) SiC Tube 1900 (1040) Flame rod or UV scanner Natural Gas, Propane, Butane (For any other mixed gas, contact Eclipse Inc.) • All information is based on laboratory testing. Different chamber size and conditions will affect the data. • Maximum inputs are given for the standard combustion air blower without an air filter. • All inputs based upon gross calorific values and standard conditions; 1 atmosphere, 70°F (21°C). • Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Performance Graphs Control & Operation Zone NOX Emission Data 100 1000 100 Propane/Butane NOX ppm % Excess Air 90 Typical Control Ratio 70 60 10 Natural Gas Input and excess air at low fire changes with ratio regulator adjustment. 1 80 0 200 400 600 50 800 1000 40 1200 0 200 Input (x 1000 BTU/hr) 0 50 100 150 200 250 400 600 800 1000 1200 Input (x 1000 BTU/hr) 300 350 0 50 100 150 200 250 300 350 Input (kW) Input (kW) NOX emission data is given for: • Ambient combustion air ~70°F (20°C) • Less than 700°F (370°C) firing chamber • Minimal process air velocity • Low fire input adjusted to 40,000 BTU/hr (12 kW) • ppm volume, dry @ 3% O2 • Neutral chamber pressure Emissions are influenced by: • Chamber conditions • Fuel type • Firing rate • Ratio regulator adjustment • Combustion air temperature CO emission is largely influenced by chamber conditions. Contact your local Eclipse Combustion representative for an estimate of CO emission on your application Fuel Orifice ∆p vs. Input ∆p Measured Between Taps B & D 5.0 3.7 2.5 5.0 12 3.0 2.5 2.0 1.5 10 8 6 Air ∆p ("w.c.) 6.2 3.5 Air ∆p (mbar) 7.5 14 Butane (13.5 mm Orifice) Propane (15.0 mm Orifice) Natural Gas (19.0 mm Orifice) 4.0 Fuel Orifice ∆p (" w.c.) Fuel Orifice ∆p (mbar) 10.0 8.7 6.0 4.5 11.2 Air ∆p vs. Air Flow High Fire Air ∆p 5.9" w.c. (14.7 mbar) (Neutral Chamber) 4.0 3.0 2.0 4 1.0 1.2 0.5 0.0 0.0 2 0 200 400 600 800 1000 1200 0 1.0 0.0 0 2000 0 50 100 150 200 Input (kW) 2 250 4000 6000 8000 10000 12000 Air Flow X 1000 scfh Input (x 1000 BTU/hr) 300 350 0 50 100 150 200 250 300 350 Air Flow Nm ³/hr Eclipse RatioAir RM100, V3, Data 110-2, 12/17/2009 Dimensions & Specifications Dimensions in Inches (mm) 771 (30.4) 341 (13.4) 236 (9.3) Filter housing 290 (11.4) C Blower housing Filter/silencer option shown in gray. B Low Fire Premix Line Propane/Butane 35 (1.4) Tap C 1" NPT or BSP gas inlet Gas inlet centerline 1/2" NPT Pilot Option 428 (16.8) D Tap B Tap D 300 (11.8) 87 (3.4) 185 (7.3) A Flame rod or UV scanner 1/2" NPT 2.5" NPT or Rc Weights lbs kg Packaged Burner 75 35 Filter Silencer 41 125.5 (4.94) 19 A B C D 50 Hz 485 (19.1) 530 (20.9) N/A N/A 60 Hz 425 (16.7) 475 (18.7) 10 (0.4) 23 (0.9) Less Blower Option Combustor Types SiC Tube Alloy Tube 4 x Ø 12 (0.47) 4 x Ø 12 (0.47) nozzle F 9 (0.4) Ø 114 (4.5) OD 190 (7.5) Ø 165 (6.49) bolt circle Ø 120 (4.7) OD Ø 165 (6.49) bolt circle 320 (12.6) E 20 (0.8) E F 255 (10.0) 84 (3.3) 330 (13.0) 160 (6.3) 406 (16.0) 236 (9.3) Eclipse RatioAir RM100, V3, Data 110-2, 12/17/2009 3 Burner Configuration Inverted right hand piping Inverted left hand piping Upright left hand piping Data 110-2, 12/17/2009 Upright right hand piping Offered By: Burnerparts.com 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3881 Fax (804) 236-3882 www.burnerparts.com