Preview only show first 10 pages with watermark. For full document please download

Eclipse Ratiomatic Burners Model Rm200 7/27/07

   EMBED


Share

Transcript

Data 110-3 7/27/07 Eclipse RatioMatic Burners Model RM200 Version 3 Main Specifications - RM200 PARAMETER SPECIFICATIONS English Motor frequency Maximum input Note: Contact factory for varying chamber pressures or pressures outside the range: -5.0 to 2.0" w.c. (-12,4 to 5,0 mbar) Metric Capacity @ Chamber Pressure BTU/hr @ "w.c. kW @ mbar 60 Hz packaged blower 2,450,000 2,350,000 2,150,000 2,050,000 1,950,000 -5.0 -3.0 0.0 1.0 2.0 718 689 630 601 571 -12,4 -7,5 0,0 2,5 5,0 50 Hz packaged blower* 2,300,000 2,200,000 2,100,000 0.0 1.0 2.0 673 644 615 0,0 2,5 5,0 Minimum input BTU/hr kW 40,000 12 Main gas inlet pressure Natural gas Propane or Butane 15 to 55 "w.c. 15 to 30 "w.c. 38 to 137 mbar 38 to 75 mbar High fire flame length Natual gas Propane or Butane 50 in 60 in 1300 mm 1500 mm ºF 1500 1900 ºC 815 1038 • fuel pressure at ratio regulator inlet • measured from the outlet end of the combustor Maximum chamber temperature Flame detection Fuel Alloy tube SiC tube Flame rod or UV scanner Natural Gas, Propane or Butane. For any other mixed gas, contact Eclipse Combustion for orifice sizing * At negative chamber pressures, capacities must be reduced. Contact factory. • All information is based on laboratory testing. Different chamber size and conditions will affect the data. • Maximum inputs are given for the standard combustion air blower without an air filter. • All inputs based upon gross calorific values and standard conditions;1 atmosphere, 70º F ( 21ºC). • Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Performance Graphs RatioMatic RM200 Control & Operation Zone 1000 NOx Emission Data 10 0 Propane Butane Typical Ratio Control 100 NOx ppm % Excess Air 90 10 At low fire, input and excess air change with ratio regulator adjustment. 0 400 100 800 1200 1600 2000 300 400 Input (kW) 500 Natural Gas 60 40 2400 Input (x 1000 BTU/hr) 200 70 50 1 0 80 600 700 0 400 100 0 800 1200 1600 2000 2400 Input (x 1000 BTU/hr) 200 300 400 Input (kW) 500 600 700 Notes on emission data NOx emission data is given for: • Ambient combustion air ~70° F (20° C) • Less than 700°F (370°C) firing chamber • Minimal process air velocity • Low fire input adjusted to 40,000 BTU/hr (12kW) • ppm volume dry at 3% O2 • Neutral chamber pressure Emissions are influenced by: • Chamber conditions • Fuel type • Firing rate • Ratio regulator adjustment • Combustion air temperature CO emission is largely influenced by chamber conditions. Contact your local Eclipse representative for an estimate of CO emission on your application. 25 Air ∆P vs. Air Flow Fuel Orifice ∆P vs. Input 10.0 (Measured between Tap C and the chamber) 10. 0 10 5 0 8.0 2Butane (19.0 mm orifice) 6.0 4.0 2.0 0.0 20 10 0 0 0 400 100 800 1200 1600 Input (x 1000 BTU/hr) 200 300 400 500 2000 600 2400 700 Input (kW) Pressure Drop (" w.c.) 15 Air ∆P firning into neutral chamber 8.8"w.c. (21.9 mbar) 2Propane (22.5 mm orifice) Pressure Drop (mbar) 20 Pressure Drop (" w.c.) Pressure Drop (mbar) 1Natural Gas (29.0 mm orifice) 8. 0 6. 0 4. 0 2. 0 0. 0 0 4 0 100 8 12 16 Air Flow (x 1000 scfh) 200 300 1Natural Gas ∆P measured between Taps B and D 2Propane and Butane ∆P measured between Tap B and the chamber 2 400 Air Flow (Nm3 /hr) Eclipse Model RM200, v3, Data 110-3, 7/27/07 20 500 24 600 Dimensions-RM200 780 (30.7) 300 (11.8) Filter/silencer option shown in gray. 244 (9.6) Dimensions in mm (in) 237 (9.3) B Low Fire Premix Line Propane/Butane 35 (1.4) Tap "C" 1-1/2" gas inlet 1/2" NPT Pilot Option 491 (19.3) Tap "B" Flame rod or UV scanner 1/2" NPT Tap "D" Gas inlet centerline 308 (12.1) 3" N.P.T. or Rc 102 (4.0) 196 (7.7) A A B 50 Hz 575 (22.6) 650 (25.6) 60 Hz 502 (19.8) 576 (22.7) 138 (5.43) Approximate weight: 105 lb (48 kg) Less Blower Option Combustor types Alloy tube SiC tube 141 (5.6) OD D 4x 12 (0.47) 148 (5.8) OD 4x nozzle 190 (7.5) bolt circle C C D 330 (13.0) 150 (5.9) 406 (16.0) 226 (8.9) 220 (8.7)OD 12 (0.47) 190 (7.5) bolt circle 320 (12.6) 220 (8.7)OD Burner configuration Inverted right hand piping Inverted left hand piping Upright left hand piping Upright right hand piping Eclipse Model RM200, v3, Data 110-3, 7/27/07 3 Offered By: Burnerparts.com 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3881 Fax (804) 236-3882 www.burnerparts.com