Preview only show first 10 pages with watermark. For full document please download

Eclipse Winnox Burners Model Wx0100

   EMBED


Share

Transcript

Data 111-5 1/30/2009 Eclipse Winnox Burners Model WX0100 Version 1 Parameter Specifications Blower Type Maximum Input, BTU/hr (kW) NOTE: Capacities given without air filter. Contact factory for chamber pressures outside the given range, or varying chamber pressure conditions. Packaged Blower Remote Blower Nominal (60Hz) Pressure at Air Inlet 1 psig (70 mbar) -5.0 (-12.5) 1,135,000 (333) 1,300,000 (381) -3.0 (-7.5) 1,080,000 (316) 1,265,000 (371) 0.0 1,000,000 (293) 1,200,000 (352) 1.0 (2.5) 970,000 (284) 1,180,000 (346) 2.0 (5.0) 940,000 (275) 1,155,000 (338) 130,000 (39) 130,000 (39) Maximum 27.7 (70) 27.7 (70) Minimum 22.0 (55) 26.0 (65) Chamber Pressure "w.c. (mbar) Minimum Input, BTU/hr (kW) Fuel Inlet Pressure at Ratio Regulator, "w.c. (mbar)1 Maximum Chamber Temperature, °F (°C) NOTE: Tube and plug temperatures should be reduced 150°F when using propane or butane. Standard combustion tube: 1300 (705) High temperature combustion tube: 1550 (845) Refractory plug: 1800 (985) Flame Length Flame is inside tube at all times. Alloy Tube Excess Air,% at High Fire 45% Piping NPT or BSP burner piping available. Flame Detection Flame rod or UV scanner. Fuels Natural gas and propane2 For any other mixed gas, contact Eclipse Inc. Blower Motor Power, Hp Weight, lbs (kg) 1.5 - Alloy Tube 192 (87) 124 (56) Refractory Plug 175 (79) 107 (48) Approvals 1 For proper performance, this pressure must be kept constant across the burner operating range. See Design Guide for more information about typical fuel composition and properties. • All information is based on laboratory testing. Different chamber size and conditions will affect data. • Maximum inputs for packaged blower versions are given for the standard combustion air blower without an inlet air filter. • All inputs are based on gross calorific values and standard conditions: one atmosphere, 70°F (20°C). • Eclipse reserves the right to change the construction and/or configurations of our products at any time without being obliged to adjust earlier supplies accordingly. 2 Performance Graphs NOX and CO Emissions Control Zone (at 3% O2) 160 400 50 140 320 40 100 80 60 240 160 NOX ppm Typical Ratio Control CO ppm % Excess Air 120 NOX - Natural Gas NOX - Propane CO - Both 30 20 40 20 0 0 200 400 600 800 1000 1200 80 10 0 0 0 Input (x 1,000 BTU/hr) 0 60 120 180 240 200 400 600 800 1000 1200 Input (x 1,000 BTU/hr) 300 360 0 Input (kW) NOTE: Input at low fire changes with ratio regulator adjustment. Secondary By-Pass Fuel Setting: Fuel ¨P "w.c. (mbar)* Natural Gas 4.0 (10.0) Propane 1.0 (2.5) *Measured between Tap “E” and the chamber @ low fire. Fuel/Input Measurement System design must include fuel flow measurement upstream of the burner. Recommended is the Eclipse 4-5 FOM (Fuel Orifice Meter) assembly number 302084-5 for natural gas. See Bulletin 930 for details. 60 120 180 240 300 360 Input (kW) NOX and CO emission data is given for: • Ambient combustion air (~70°F, 20°C) • Less than 1000°F (540°C) firing chamber • Minimal process air velocity • Low fire input adjusted to 143,000 BTU/hr (42 kW) • Neutral chamber pressure Emissions are influenced by: • Chamber conditions • Fuel type • Firing rate • Ratio regulator adjustments • Combustion air temperature CO emission is largely influenced by chamber conditions. Contact your local Eclipse representative for an estimate of CO emission on your application. NOTE: Insure burner inlet pressures are met. Air ∆P vs. Input 45 18 40 16 35 14 30 25 20 15 Air ∆P ("w.c.) Air ∆P (mbar) (Measured Between Tap "C" and the Chamber) At low fire, air ∆P firing into neutral chamber is 0.3" w.c. (0.75 mbar) 12 10 8 6 10 4 5 2 0 0 0 200 400 600 800 1000 1200 Input (x 1,000 BTU/hr) 0 60 120 180 240 300 360 Input (kW) 2 Eclipse Winnox Model WX0100, V1, Data 111-5, 1/30/2009 Packaged Blower Dimensions in inches (mm) 30.7 (780) 9.6 (243) Optional filter / silencer & pressure switch shown in gray 23.5 (598) 12.3 (313) 26.4 (671) 1” NPT or 1" BSP Fuel Inlet 7 (178) 15.5 (394) Tap "C" Tap "E" 4.3 (109) Ø11.1 (281) Ø11.8 (300) UV Scanner Location Tap "B" 17.6 (447) Ø15.2 (385) 7.3 (184) Ø13.6 (345) 8x Ø0.47 (12) Refractory Plug 8.1 (207) 17.3 (440) Configured for Pilot 1/2" NPT or 1/2" BSP Gas Pilot Inlet Fiber Insulation Ø11.5 (293) 6 mm Gap 6 (153) Ø11 (281) 15.1 (384) Customer Supplied Refractory Remote Blower NOTE: For Remote Blower applications, consult factory. 1" NPT or 1" BSP Fuel Inlet 4.1 (103) 3" BSP 7 (178) Tap “C” 5.4 (138) Tap “E” Ø11.1 (281) Ø11.8 (300) Tap “B” Ø15.2 17.6 (385) (447) Ø13.6 (345) 8 x Ø0.47 (12) Eclipse Winnox Model WX0100, V1, Data 111-5, 1/30/2009 7.3 (184) 8.1 (207) 17.3 (440) 3 Offered By: Burnerparts.com 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3881 Fax (804) 236-3882 www.burnerparts.com