Preview only show first 10 pages with watermark. For full document please download

Eco 2 - Wiring Diagram

   EMBED


Share

Transcript

2 1 3 4 5 6 7 8 © Classeq Ltd. Air Pressure Switch (APS) Data CAM timer data Neutral 12 21 14 22 31 24 32 on Cam 2 off 23 -L3 34 A2 N N L1 L2 L3 Cycle timer Spülprogrammlaufwerk 560.3120 120 sec 53A -Tm1 Earth 30 -TB1 Cam 4 on off A Air pressure vessel APS 2 - Set point (105mm) Adjustable 0:00 Terminal block Anschlussklemmenleiste 7.12.70 Cam 3 on off APS 1 = Air Pressure Switch 1, (terminals 11,12 & 14) APS 2 = Air Pressure Switch 1, (terminals 21,22 & 24) APS 2 - Hysteresis APS 2 - Reset point (77mm) APS 1 - Set point (77mm) APS 1 - Hysteresis 2:00 Phase 1 11 (none adjustable air pressure switch) Key 143 Latch relay Verriegelungsschütz CONT 30 62.83.8.230.0000 47 -CT3 Cam 1 0:05 A Cycle lamp Lampe Spülprogramm aktiv 505.0004 A1 on off 0:03 PE Time Wash air pressure switch Niveauschalter Tank 530.0001 A2-DP0401 17 -APS2 Glass washers = 2 minute timer (as shown) = part no. 560.3120 Dishwashers = 3 min timer = part no. 560.3180 APS 1- Reset point (15mm) Datum (0mm) Wash cabinet B B Ready lamp Lampe Spülprogramm beendet 505.0002 Breaker Überstromschalter TCB-1 ZE-700-4 90 -SD1 27 -L2 Interlock options Thermostop Optionen Default = Quick Start 39X Interlock Quick Start Interlock removed Cycle switch Start Spülprogramm 501.0001 Door switch Türendschalter 570.0001 PS2011 19 -Sw3 C Door relay Tür Schütz CONT 30 62.83.8.230.0000 407 -CT2 Cycle timer Spülprogrammlaufwerk 560.3120 120 sec 53A -Tm1 11 -Sw2 L1 31 21 11 41 55°c quick start 55°C Schnellstart 541.0002 M1 12 14 N1 22 24 32 34 42 44 C 72A -Trip3 A1 11 12 14 22 21 31 24 32 Rinse air pressure switch Niveauschalter Boiler 530.0001 A2-DP0401 16 -APS1 34 A2 12 11 21 14 22 24 Wash air pressure switch Niveauschalter Tank 530.0001 A2-DP0401 17 -APS2 12 11 21 14 22 24 D 11 12 14 22 21 24 32 31 34 Inlet valve Einlass Magnetventil 7.12.12/1 A2 On / OFF lamp Ein / Aus Lampe 505.0001 E 4 A1 On/Off relay Ein / Aus Schütz CONT 30 62.83.8.230.0000 46 -CT1 10 -Sw1 1 Rinse heater relay Boiler Heizungs Schütz 540.0002 105'c 67 -IS1 21 -L1 Wash thermostat Tank Thermostat 542.0002 97.55172.069 2 73 -ST2 Airbreak M/C's Pressurised M/C's On / OFF switch Ein / Aus Schalter 500.0001 Rinse thermostat Boiler Thermostat 542.0002 97.55172.069 2 72 -ST1 Airbreak M/C's Pressurised M/C's D + - Wash pump Spül Pumpe 522.0001 CP50-163 64 -P2 1 4 E C 2 5 N 3 6 L C Drain pump Ablaufpumpe DP2 DPS25-091 66 -P3 L Rinse capactor Kondensator für Nachspülpumpe 529.0002 4mF N 69 -C1 + - 4 E -Trip1 Wash capacitor Kondensator für Spül Pumpe 529.0001 5mF 68 -C2 1 Wash safety stat Tank Sicherheits Thermostat 540.0001 85'c -Trip2 Rinse pump Nachspülpumpe 520.0001 UP30-160 63 -P1 C LC N E Chemical pumps Reinigungsmittelpumpen 526.0010 P2R005A1301A2 60,61 -P4 Detergent Rinse aid L N L Rinse element Boilerheizkörper 550.0003 2.6 kW N -E1 Wash element Tankheizkörper 555.0001 2.0 kW L -E2 N F F - D Chem pumps MRD 21/07/09 - E Aligning dwg to harness MRD 06/04/10 are the confidential and copywright property of CLASSEQ LTD and must DCN0116 F Adjustable cam timer MRD 26/01/11 not be disclosed, loaned, copied or used for manufacturing, tendering or DCN No. Revision Comment 1 Name This drawing and any information or descriptive matter set out hereon Date any other purpose without writtern permission from Classeq Ltd. 2 3 4 Special Notes Title Eco 1, Eco 2, Hydro 500, Duo 2, Duo 500 Standards CE P2 - Standard 13 Amp wiring harness Standard 13 A Kabelbaum Loom / Dwg No. 5 6 LM-P2-13A 7 M Downing Drawn Approved Date Sheet 8 07.07.08 1 of 1