ECO User Guide The Access Keypad The Keypad provides four separate functions: • Local audible and visual alarms • Bypass function to escort residents through the protected exit • Alarm reset when the Controller is in continuous alarm mode or resets the bypass sequence • Controller status indication via the LED indicators The Controller may be bypassed or reset at an exit point by entering a 3- to 7-digit code at the keypad. Bypass (Green LED) Alarm (Red LED) Power (Yellow LED) Clear Function Enter Function Status Indicator Condition Cause Action Power OFF Power is off Turn Power ON Solid Yellow Power ON, Ready Mode None; system ready Bypass Flashing Green/Red + Beeping tone Bypass Mode Escort resident immediately Alarm Flashing Red + Beeping tone Alarm Mode Investigate; reset alarm Escorting Residents (Bypass) 1. 2. 3. 4. Bring the resident to the exit, ensuring that he or she is not in the detection zone. Enter the on the keypad. Press <#> on the keypad. Escort the resident through the exit. Note: There are three automatic timers enabled by the system when the bypass function is activated: • Bypass Timeout: You have 10 seconds to enter the detection zone after the bypass code is entered. If no tag enters the zone within the 10-second period, the bypass is terminated. • Transport: Once the tag enters the detection zone, you have 90 seconds to transport the resident through the zone before the alarm is activated. • Rearm: After the tag is through the zone or the door closes, the system automatically resets itself in 8 seconds. Reset an Alarm • Enter the on the keypad and press <#>. Clear or Correct an Entry • To clear or correct an entry, press <*> on the keypad. Stanley Security Solutions Stanley Healthcare Solutions Division 1550 N. 20th Circle, Lincoln, NE 68503 Tel: USA: 800-824-2996 Canada: 866-559-6275 Int’l: +1 (613) 592-6997 Web: www.stanleyhealthcare.com © 2010 Stanley Security Solutions, Inc. All Rights Reserved. October 2010. 980-000009-000 Rev 04 2 Optional ANN6L Six-Zone Annunciator (AGEAN01-060, North America only) Zone Location Status Indicator Up to 6 zones can be displayed on the annunciator. These zones are usually labelled during installation. Adjacent to each identified zone on the panel is a Status Indicator that flashes either red or yellow to provide a visual alarm. Audible Alarm Two distinct audible alarm tones are generated when a tag enters the detection zone ; one when the door is open and the other when the door is closed. RESET Button Silences an alarm, and resets the system if the Reset Output is connected to the Door Controllers. All alarms in the system are reset. (The system can only be reset if no tags are in the detection zone). SILENCE Button Silences the audible alarm, even with a tag in the zone. The Status Indicator continues to flash until the alarm is investigated. Status Indicator Audible Tone Door Status Cause Action Standby None Closed No tag in zone None required Flashing Warning Closed YELLOW Tone Tag in zone 1. Investigate cause 2. Ensure resident safety 3. Reset panel Flashing Alarm Tone RED Tag in or passing 1. Investigate cause through zone 2. Ensure resident safety 3. Reset panel Open • To silence the audible alarm, press . Note: The audible alarm is silenced, but the RED indicator continues to flash. • To reset the audible alarm, press . Note: The RESET button only works if there are no tags in the detection zone. Warranty Stanley Healthcare Solutions’ RoamAlert ECO hardware is warranted against defects in materials and workmanship and shall perform in accordance with published specifications for 1 year from the date of installation. Stanley Healthcare Solutions’ warranty is limited solely to the repair or replacement of the defective part or product. Stanley Healthcare Solutions reserves the right to change product specifications without notice. Copyright Information All content herein is the property of Stanley Black & Decker, Inc., its Affiliates, or their content suppliers and is protected by United States and international copyright laws. The compilation of all content is likewise the exclusive property of Stanley Black & Decker, Inc. (or the Affiliate identified in any copyright notice) and is protected by United States and international copyright laws. The trademarks, service marks and logos (the ‘Trademarks’) used and displayed in this publication are registered and unregistered Trademarks of Stanley Black & Decker, Inc., its Affiliates and others. Nothing herein should be construed as granting, by implication, estoppel or otherwise, any license or right to use any Trademark displayed herein without the prior consent of the Trademark owner. Stanley and the Stanley design are two of the trademarks owned by Stanley Black & Decker, Inc. and/or its Affiliates (“Stanley Black & Decker Trademarks”). Stanley Black & Decker Trademarks may not be used in connection with any product or service that is not manufactured by or under license from Stanley Black & Decker, Inc. or its appropriate Affiliate. RoamAlert ECO User Guide