Preview only show first 10 pages with watermark. For full document please download

Eco2l2c - Contrast Lighting

   EMBED


Share

Transcript

SPECIFICATION SHEET PAGE 1/5 ECO2L2C Project Notes 4" ECO2LED Series Fixture Type Date Round Shower Trim SPECIFICATIONS COLOR TEMPERATURE 2700K or 3000K CRI 80 + 90 + LED MODULE Lumiled Luxeon CoB 9W, delivers a lumen maintenance greater than 70% after 50,000 hours of operation (L70). Provides a clean white light without pixilation and produces a high quality true color, inside 3 steps MacAdam ellipse. LUMENS OUTPUT Up to 492 Lumens, 46 lm/W LIFESPAN 50,000 hours TRIM Powder coat painted or plated die-formed steel. Different finishes available. Painted finishes available with Marine Grade option. BEAM W: Wide Flood LENS Tempered Glass Frosted lens. HEAT SINK High quality injected aluminum ensuring maximum heat dissipation. CEILING CUTOUT Ø 4-1/4" (108 mm) COMPATIBLE HOUSINGS IC and Airtight Remodel Housing: ECO2REL200-120D (120V Compatible Dimming) ECO2REL200-277 (277V) IC and Airtight New Construction Housing: ECO2NWL200-120D (120V Compatible Dimming) ECO2NWL200-277 (277V) IC and Airtight Box: ECO2ISL200-120D (120V Compatible Dimming) ECO2ISL200-277 (277V) ECO2ISL200P-120D (120V Compatible Dimming) ECO2ISL200P-277 (277V) ECO2L2C-04BR (illustrated) 54° 4-1/2" (115 mm) 1/8" (3 mm) For dimming, please refer to the selected housing specification sheet. CERTIFICATION • cULus E343977 for wet locations • Title 24 compliant WARRANTY 5-year warranty on ECO2LED Module and Driver. Ø 4-7/8" (124 mm) Ø 2-15/16" (75 mm) LED Product Partner RoHS 1009, rue du Parc Industriel Lévis (Québec) G6Z 1C5 Canada Tel.: 1-888-839-4624 2016-05 Fax: 1-877-839-7057 [email protected] www.contrastlighting.com © 2016 Contrast Lighting M.L. Inc. All rights reserved Contrast Lighting reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. SPECIFICATION SHEET PAGE 2/5 ECO2L2C 4" ECO2LED Series PHOTOMETRIC DATA 2700K, 80+ CRI, Wide Flood CANDLEPOWER DISTRIBUTION Candelas 90° 90 75° 270 60° 45° 430 0° 15° LUMENS 273 358 437 28 465 Distance FC DIA 06’ 14,3 5,6’ COEFFICIENT OF UTILIZATION - % ECO2L2C 2700K Wide Flood 50W GU10 514 / 465 120V 10,7W 0,099A L70 @ 50,000 Hrs 80 + 44,7 0,8 08’ 8,0 7,5’ Equivalent Lamp CBCP / Lumens 10’ 5,1 9,3’ Watts 12’ 3,6 11,2’ 14’ 2,6 13,1’ Beam: 50˚ Beam Edge defined as 50% of Maximum Nadir Candle-power. 30° ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 60-90 0-90 LUMINAIRE LIGHT CONE Operating AMPS Lumen Maintenance CRI Lumens/Watt Spacing Criteria Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 50 30 50 30 50 30 119 119 111 111 106 106 100 95 95 91 91 88 84 78 81 76 79 74 73 66 70 65 69 64 64 57 62 56 61 56 56 50 55 50 54 49 Zonal Cavity Method Effective Floor Cavity Reflectance 20% CANDELAS DISTRIBUTION %LUMINAIRE 58,8% 77,1% 93,9% 6,1% 100% DEGREES/ VERTICAL CANDELAS 0 5 10 15 20 25 35 514 499 456 396 327 257 135 DEGREES/ VERTICAL CANDELAS 45 55 65 75 85 90 62 32 17 8 2 0 2700K, 90+ CRI, Wide Flood CANDLEPOWER DISTRIBUTION Candelas 90° 80 75° 230 60° 45° 375 0° 15° 30° ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 60-90 0-90 LUMENS 236 310 378 24 402 %LUMINAIRE 58,8% 77,1% 93,9% 6,1% 100% LUMINAIRE LIGHT CONE COEFFICIENT OF UTILIZATION - % Distance FC DIA ECO2L2C 2700K Wide Flood 06’ 12,4 5,6’ 08’ 7,0 7,5’ Equivalent Lamp CBCP / Lumens 10’ 4,5 9,3’ Watts 12’ 3,1 11,2’ 14’ 2,3 13,1’ 50W GU10 445 / 402 120V 10,7W 0,099A L70 @ 50,000 Hrs 90 + 38,4 0,8 Beam: 50˚ Beam Edge defined as 50% of Maximum Nadir Candle-power. Operating AMPS Lumen Maintenance CRI Lumens/Watt Spacing Criteria Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 50 30 50 30 50 30 119 119 111 111 106 106 100 95 95 91 91 88 84 78 81 76 79 74 73 66 70 65 69 64 64 57 62 56 61 56 56 50 55 50 54 49 Zonal Cavity Method Effective Floor Cavity Reflectance 20% CANDELAS DISTRIBUTION DEGREES/ VERTICAL CANDELAS 0 5 10 15 20 25 35 445 431 394 342 283 223 117 DEGREES/ VERTICAL CANDELAS 45 55 65 75 85 90 54 28 15 7 2 0 RoHS LED Product Partner 1009, rue du Parc Industriel Lévis (Québec) G6Z 1C5 Canada Tel.: 1-888-839-4624 2016-05 Fax: 1-877-839-7057 [email protected] www.contrastlighting.com © 2016 Contrast Lighting M.L. Inc. All rights reserved Contrast Lighting reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. SPECIFICATION SHEET PAGE 3/5 ECO2L2C 4" ECO2LED Series PHOTOMETRIC DATA 3000K, 80+ CRI, Wide Flood CANDLEPOWER DISTRIBUTION Candelas 90° 90 75° 270 60° 45° 450 0° 15° LUMENS 285 373 455 29 484 Distance FC DIA 06’ 14,9 5,6’ COEFFICIENT OF UTILIZATION - % ECO2L2C 3000K Wide Flood 35W MR16 536 / 484 120V 10,7W 0,099A L70 @ 50,000 Hrs 80 + 46,1 0,8 472938 08’ 8,4 7,5’ Equivalent Lamp CBCP / Lumens 10’ 5,4 9,3’ Watts 12’ 3,7 11,2’ 14’ 2,7 13,1’ Beam: 50˚ Beam Edge defined as 50% of Maximum Nadir Candle-power. 30° ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 60-90 0-90 LUMINAIRE LIGHT CONE Operating AMPS Lumen Maintenance CRI Lumens/Watt Spacing Criteria Certificate LM79-08 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 50 30 50 30 50 30 119 119 111 111 106 106 102 98 97 94 94 92 89 83 86 81 84 80 78 72 76 71 74 70 69 63 67 62 66 61 61 55 60 55 59 54 Zonal Cavity Method Effective Floor Cavity Reflectance 20% CANDELAS DISTRIBUTION %LUMINAIRE 58,8% 77,1% 93,9% 6,1% 100% DEGREES/ VERTICAL CANDELAS 0 5 10 15 20 25 35 536 519 475 412 341 268 141 DEGREES/ VERTICAL CANDELAS 45 55 65 75 85 90 65 33 18 8 3 0 3000K, 90+ CRI, Wide Flood CANDLEPOWER DISTRIBUTION Candelas 90° 90 75° 270 60° 45° 450 0° 15° 30° ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 60-90 0-90 LUMENS 248 325 396 26 421 %LUMINAIRE 58,8% 77,1% 93,9% 6,1% 100% LUMINAIRE LIGHT CONE COEFFICIENT OF UTILIZATION - % Distance FC DIA ECO2L2C 3000K Wide Flood 06’ 12,9 5,6’ 08’ 7,3 7,5’ Equivalent Lamp CBCP / Lumens 10’ 4,7 9,3’ Watts 12’ 3,2 11,2’ 14’ 2,4 13,1’ 35W MR16 466 / 421 120V 10,7W 0,099A L70 @ 50,000 Hrs 90 + 40 0,8 Beam: 50˚ Beam Edge defined as 50% of Maximum Nadir Candle-power. Operating AMPS Lumen Maintenance CRI Lumens/Watt Spacing Criteria Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 50 30 50 30 50 30 119 119 111 111 106 106 100 95 95 91 91 88 84 78 81 76 79 74 73 66 70 65 69 64 64 57 62 56 61 56 56 50 55 50 54 49 Zonal Cavity Method Effective Floor Cavity Reflectance 20% CANDELAS DISTRIBUTION DEGREES/ VERTICAL CANDELAS 0 5 10 15 20 25 35 466 452 413 359 296 233 122 DEGREES/ VERTICAL CANDELAS 45 55 65 75 85 90 57 29 16 7 2 0 RoHS LED Product Partner 1009, rue du Parc Industriel Lévis (Québec) G6Z 1C5 Canada Tel.: 1-888-839-4624 2016-05 Fax: 1-877-839-7057 [email protected] www.contrastlighting.com © 2016 Contrast Lighting M.L. Inc. All rights reserved Contrast Lighting reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. SPECIFICATION SHEET PAGE 4/5 ECO2L2C 4" ECO2LED Series LIGHTING FACTS LED Product Partner RoHS 1009, rue du Parc Industriel Lévis (Québec) G6Z 1C5 Canada Tel.: 1-888-839-4624 2016-05 Fax: 1-877-839-7057 [email protected] www.contrastlighting.com © 2016 Contrast Lighting M.L. Inc. All rights reserved Contrast Lighting reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. SPECIFICATION SHEET PAGE 5/5 ECO2L2C 4" ECO2LED Series CODIFICATION EXAMPLE ECO2L2C-01MG280M MODEL MARINE GRADE OPTION TRIM FINISH CRI COLOR BEAM TEMPERATURE ORDERING CODE MODEL TRIM FINISH COLOR TEMPERATURE MARINE GRADE CRI BEAM ECO2L2C ECO2L2C W -01 -02 -04BR -11 -12BR -15 White Black Brushed Chrome Matte White Brushed Nickel Metallic Grey MG (optional) May be applied on finishes: -01, -02, -11 and -15 2 3 2700K 3000K 80 90 CRI 80 + CRI 90 + W Wide Flood (54°) MARINE GRADE - Unless otherwise indicated, trims are for interior, cold and exterior locations where fixtures are not subject to direct rain or snow exposure as in soffits. MARINE GRADE treatment is recommended for exterior, shower and high salinity environment. LED Product Partner RoHS 1009, rue du Parc Industriel Lévis (Québec) G6Z 1C5 Canada Tel.: 1-888-839-4624 2016-05 Fax: 1-877-839-7057 [email protected] www.contrastlighting.com © 2016 Contrast Lighting M.L. Inc. All rights reserved Contrast Lighting reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.