SPECIFICATION SHEET
PAGE 1/5
ECO2L2C
Project Notes
4" ECO2LED Series
Fixture Type Date
Round Shower Trim
SPECIFICATIONS COLOR TEMPERATURE
2700K or 3000K
CRI
80 + 90 +
LED MODULE
Lumiled Luxeon CoB 9W, delivers a lumen maintenance greater than 70% after 50,000 hours of operation (L70). Provides a clean white light without pixilation and produces a high quality true color, inside 3 steps MacAdam ellipse.
LUMENS OUTPUT
Up to 492 Lumens, 46 lm/W
LIFESPAN
50,000 hours
TRIM
Powder coat painted or plated die-formed steel. Different finishes available. Painted finishes available with Marine Grade option.
BEAM
W: Wide Flood
LENS
Tempered Glass Frosted lens.
HEAT SINK
High quality injected aluminum ensuring maximum heat dissipation.
CEILING CUTOUT
Ø 4-1/4" (108 mm)
COMPATIBLE HOUSINGS
IC and Airtight Remodel Housing: ECO2REL200-120D (120V Compatible Dimming) ECO2REL200-277 (277V) IC and Airtight New Construction Housing: ECO2NWL200-120D (120V Compatible Dimming) ECO2NWL200-277 (277V) IC and Airtight Box: ECO2ISL200-120D (120V Compatible Dimming) ECO2ISL200-277 (277V) ECO2ISL200P-120D (120V Compatible Dimming) ECO2ISL200P-277 (277V)
ECO2L2C-04BR (illustrated)
54°
4-1/2" (115 mm)
1/8" (3 mm)
For dimming, please refer to the selected housing specification sheet. CERTIFICATION
• cULus E343977 for wet locations • Title 24 compliant
WARRANTY
5-year warranty on ECO2LED Module and Driver.
Ø 4-7/8" (124 mm)
Ø 2-15/16" (75 mm)
LED Product Partner
RoHS 1009, rue du Parc Industriel Lévis (Québec) G6Z 1C5 Canada Tel.: 1-888-839-4624 2016-05
Fax: 1-877-839-7057
[email protected] www.contrastlighting.com
© 2016 Contrast Lighting M.L. Inc. All rights reserved Contrast Lighting reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.
SPECIFICATION SHEET
PAGE 2/5
ECO2L2C 4" ECO2LED Series
PHOTOMETRIC DATA
2700K, 80+ CRI, Wide Flood CANDLEPOWER DISTRIBUTION Candelas
90°
90
75°
270
60° 45°
430 0°
15°
LUMENS 273 358 437 28 465
Distance
FC
DIA
06’
14,3
5,6’
COEFFICIENT OF UTILIZATION - %
ECO2L2C
2700K Wide Flood 50W GU10 514 / 465 120V 10,7W 0,099A L70 @ 50,000 Hrs 80 + 44,7 0,8
08’
8,0
7,5’
Equivalent Lamp CBCP / Lumens
10’
5,1
9,3’
Watts
12’
3,6
11,2’
14’
2,6
13,1’
Beam: 50˚ Beam Edge defined as 50% of Maximum Nadir Candle-power.
30°
ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 60-90 0-90
LUMINAIRE
LIGHT CONE
Operating AMPS Lumen Maintenance CRI Lumens/Watt Spacing Criteria
Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10
80 50 30 50 30 50 30 50 30 119 119 111 111 106 106 100 95 95 91 91 88 84 78 81 76 79 74 73 66 70 65 69 64 64 57 62 56 61 56 56 50 55 50 54 49
Zonal Cavity Method Effective Floor Cavity Reflectance 20%
CANDELAS DISTRIBUTION
%LUMINAIRE 58,8% 77,1% 93,9% 6,1% 100%
DEGREES/ VERTICAL
CANDELAS
0 5 10 15 20 25 35
514 499 456 396 327 257 135
DEGREES/ VERTICAL
CANDELAS
45 55 65 75 85 90
62 32 17 8 2 0
2700K, 90+ CRI, Wide Flood CANDLEPOWER DISTRIBUTION Candelas
90°
80
75°
230
60° 45°
375 0°
15°
30°
ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 60-90 0-90
LUMENS 236 310 378 24 402
%LUMINAIRE 58,8% 77,1% 93,9% 6,1% 100%
LUMINAIRE
LIGHT CONE
COEFFICIENT OF UTILIZATION - %
Distance
FC
DIA
ECO2L2C
2700K Wide Flood
06’
12,4
5,6’
08’
7,0
7,5’
Equivalent Lamp CBCP / Lumens
10’
4,5
9,3’
Watts
12’
3,1
11,2’
14’
2,3
13,1’
50W GU10 445 / 402 120V 10,7W 0,099A L70 @ 50,000 Hrs 90 + 38,4 0,8
Beam: 50˚ Beam Edge defined as 50% of Maximum Nadir Candle-power.
Operating AMPS Lumen Maintenance CRI Lumens/Watt Spacing Criteria
Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10
80 50 30 50 30 50 30 50 30 119 119 111 111 106 106 100 95 95 91 91 88 84 78 81 76 79 74 73 66 70 65 69 64 64 57 62 56 61 56 56 50 55 50 54 49
Zonal Cavity Method Effective Floor Cavity Reflectance 20%
CANDELAS DISTRIBUTION DEGREES/ VERTICAL
CANDELAS
0 5 10 15 20 25 35
445 431 394 342 283 223 117
DEGREES/ VERTICAL
CANDELAS
45 55 65 75 85 90
54 28 15 7 2 0
RoHS LED Product Partner
1009, rue du Parc Industriel Lévis (Québec) G6Z 1C5 Canada Tel.: 1-888-839-4624 2016-05
Fax: 1-877-839-7057
[email protected] www.contrastlighting.com
© 2016 Contrast Lighting M.L. Inc. All rights reserved Contrast Lighting reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.
SPECIFICATION SHEET
PAGE 3/5
ECO2L2C 4" ECO2LED Series
PHOTOMETRIC DATA
3000K, 80+ CRI, Wide Flood CANDLEPOWER DISTRIBUTION Candelas
90°
90
75°
270
60° 45°
450 0°
15°
LUMENS 285 373 455 29 484
Distance
FC
DIA
06’
14,9
5,6’
COEFFICIENT OF UTILIZATION - %
ECO2L2C
3000K Wide Flood 35W MR16 536 / 484 120V 10,7W 0,099A L70 @ 50,000 Hrs 80 + 46,1 0,8 472938
08’
8,4
7,5’
Equivalent Lamp CBCP / Lumens
10’
5,4
9,3’
Watts
12’
3,7
11,2’
14’
2,7
13,1’
Beam: 50˚ Beam Edge defined as 50% of Maximum Nadir Candle-power.
30°
ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 60-90 0-90
LUMINAIRE
LIGHT CONE
Operating AMPS Lumen Maintenance CRI Lumens/Watt Spacing Criteria Certificate LM79-08
Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10
80 50 30 50 30 50 30 50 30 119 119 111 111 106 106 102 98 97 94 94 92 89 83 86 81 84 80 78 72 76 71 74 70 69 63 67 62 66 61 61 55 60 55 59 54
Zonal Cavity Method Effective Floor Cavity Reflectance 20%
CANDELAS DISTRIBUTION
%LUMINAIRE 58,8% 77,1% 93,9% 6,1% 100%
DEGREES/ VERTICAL
CANDELAS
0 5 10 15 20 25 35
536 519 475 412 341 268 141
DEGREES/ VERTICAL
CANDELAS
45 55 65 75 85 90
65 33 18 8 3 0
3000K, 90+ CRI, Wide Flood CANDLEPOWER DISTRIBUTION Candelas
90°
90
75°
270
60° 45°
450 0°
15°
30°
ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 60-90 0-90
LUMENS 248 325 396 26 421
%LUMINAIRE 58,8% 77,1% 93,9% 6,1% 100%
LUMINAIRE
LIGHT CONE
COEFFICIENT OF UTILIZATION - %
Distance
FC
DIA
ECO2L2C
3000K Wide Flood
06’
12,9
5,6’
08’
7,3
7,5’
Equivalent Lamp CBCP / Lumens
10’
4,7
9,3’
Watts
12’
3,2
11,2’
14’
2,4
13,1’
35W MR16 466 / 421 120V 10,7W 0,099A L70 @ 50,000 Hrs 90 + 40 0,8
Beam: 50˚ Beam Edge defined as 50% of Maximum Nadir Candle-power.
Operating AMPS Lumen Maintenance CRI Lumens/Watt Spacing Criteria
Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10
80 50 30 50 30 50 30 50 30 119 119 111 111 106 106 100 95 95 91 91 88 84 78 81 76 79 74 73 66 70 65 69 64 64 57 62 56 61 56 56 50 55 50 54 49
Zonal Cavity Method Effective Floor Cavity Reflectance 20%
CANDELAS DISTRIBUTION DEGREES/ VERTICAL
CANDELAS
0 5 10 15 20 25 35
466 452 413 359 296 233 122
DEGREES/ VERTICAL
CANDELAS
45 55 65 75 85 90
57 29 16 7 2 0
RoHS LED Product Partner
1009, rue du Parc Industriel Lévis (Québec) G6Z 1C5 Canada Tel.: 1-888-839-4624 2016-05
Fax: 1-877-839-7057
[email protected] www.contrastlighting.com
© 2016 Contrast Lighting M.L. Inc. All rights reserved Contrast Lighting reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.
SPECIFICATION SHEET
PAGE 4/5
ECO2L2C 4" ECO2LED Series
LIGHTING FACTS
LED Product Partner
RoHS 1009, rue du Parc Industriel Lévis (Québec) G6Z 1C5 Canada Tel.: 1-888-839-4624 2016-05
Fax: 1-877-839-7057
[email protected] www.contrastlighting.com
© 2016 Contrast Lighting M.L. Inc. All rights reserved Contrast Lighting reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.
SPECIFICATION SHEET
PAGE 5/5
ECO2L2C 4" ECO2LED Series
CODIFICATION EXAMPLE
ECO2L2C-01MG280M MODEL
MARINE GRADE OPTION
TRIM FINISH
CRI
COLOR BEAM TEMPERATURE
ORDERING CODE MODEL
TRIM FINISH
COLOR TEMPERATURE
MARINE GRADE
CRI
BEAM
ECO2L2C ECO2L2C
W -01 -02 -04BR -11 -12BR -15
White Black Brushed Chrome Matte White Brushed Nickel Metallic Grey
MG (optional) May be applied on finishes: -01, -02, -11 and -15
2 3
2700K 3000K
80 90
CRI 80 + CRI 90 +
W
Wide Flood (54°)
MARINE GRADE - Unless otherwise indicated, trims are for interior, cold and exterior locations where fixtures are not subject to direct rain or snow exposure as in soffits. MARINE GRADE treatment is recommended for exterior, shower and high salinity environment.
LED Product Partner
RoHS 1009, rue du Parc Industriel Lévis (Québec) G6Z 1C5 Canada Tel.: 1-888-839-4624 2016-05
Fax: 1-877-839-7057
[email protected] www.contrastlighting.com
© 2016 Contrast Lighting M.L. Inc. All rights reserved Contrast Lighting reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.