Transcript
ECOi and ECO G indoor units dimensions U1 Type // 4 Way 90x90 Cassette
745 (suspension bolt pitch)
8
Ø 150 4-12x30 slot Ø 100¹
X
421
1 Air inlet kit is necessary. Filter size: 520 x 520 x 16
106-160 319 187
B
786 (suspension bolt pitch)
Ø 6.35 (flared) Ø 9.52 (flared) Ø 12.7 (flared) Ø 15.88 (flared) Outer diameter 32mm
22-90 256 124
167 130 95
Type A B
860~910 (ceiling opening dimension)
130
60-160
860~910 (ceiling opening dimension)
22-56
(411)
Type 1 Air intake grill 2 Air discharge outlet 3 Refrigerant piping (liquid pipes) 4 Refrigerant piping (gas pipes) 5 Drain outlet VP50 6 Power supply port 7 Discharge duct 8 Suspension bolt hole 9 Fresh air intake duct connection port
480 7
X VIEW 345
4
3
5 840
840 480
271
50
82
950 514
160
A 42 121
6
7
300 Less than
4-Ø3 g hole Burrin
9
2
18
115
2
Bur
950
4-Ø3 ring hole
515
115
30
670 850
2
Ø16
80
1 3
Ø11
7
2 118
7
95
Less than 35
33.5
160
167 Less than 35
160
50
145
B
180
2
80
Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 30mm or more (18mm or more from the lower surface of the body) as shown in the figure. When the suspension bolt length is long, it hits the ceiling panel and installation is not possible.
2
Dimensions: mm
Y2 Type // 4 Way 60x60 Cassette A 650 (ceiling opening dimension)
700 336
530 (suspension bolt pitch)
320
316
301
336
700
212
Panel center
650 (ceiling opening dimension)
7 1
530 (suspension bolt pitch)
2
148
8
A VIEW
2 (583)
(583)
575 200
575 170
146
5
71
ø 80
Dimension of Fresh air intake duct (field supply) connection port
314
71
6
ole
ing h
Barr
4-ø3
4 3
1 2 3 4 5 6 7 8
45
(288)
283
31 (23)
31
112
123
179
260
25
44
Air intake Discharge outlet Refrigerant tubing (liquid tube) Ø 6.35 (flared) Refrigerant tubing (gas tube) Ø 12.7 (flared) Drain tube connection port VP25 Outer dia. Ø 32 Power supply port Suspension bolt hole 4-11 x 26 hole Fresh air intake duct connection port Ø 80
Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 45mm or more, as shown in the figure at right. If the suspension bolts is too long, it will contact the ceiling panel and the unit cannot be installed. Dimensions: mm
VRF SYSTEMS
L1 Type // 2 Way Cassette Ø 9.52 Ø 15.88 Outer diameter 32mm
Inspection panel for drain pump
20
Refrigerant liquid line Refrigerant gas line Drain connection 25 A Power supply entry
3
590
Suspension holes
630 1320 1360
Ceiling opening (1.320 x 640)
1
110 30
Fresh air intake (for Ø 125 duct flange)
80 For discharge duct (2-Ø 150 hole)
70
4
290
70
165
75 195 1 220 310 350
2
1140 4
40 70 20
Inspection panel for ECV, drain pan
530 600 640
Panel Center
680
1 2 3 4
102
8
60
23
680
680
1360
Dimensions: mm
1060 (suspension bolt pitch)
e hol .1 Ø3
k-o ut
hole )
20
20
356
200
95 76
61 41
Fresh air intake duct connection port (detail)
Required space for installation
6
FRONT VIEW
20
92
112
noc
Ø113
1000 1190 (ceiling opening dimension)
154
7
0 (k
4–
710
3
726 706 363
230
Ø10
216 80
4
94
25
20 8
5
10
135
475 (suspension bolt pitch) 220 255
760 (ceiling opening dimension)
28-56 73 Air intake grille Discharge outlet Refrigerant piping (liquid pipes) Ø 6.35 (flared) Ø 9.52 (flared) Refrigerant piping (gas pipes) Ø 12.7 (flared) Ø 15.88 (flared) Drain connection VP25 Outer diameter32 Power supply entry Discharge duct connection port (for descending ceiling) Fresh air intake duct connection port Ø 100 Installation port for wireless remote controller receiver Suspension bolt hole 4–12 30 hole
2 1000 or more
200 or more
9
800
200 or more
1000 or more
200 or more
1000 or more
1 2 3 4 5 6 7 8 9 10
20
D1 Type // 1 Way Cassette
1230
1
Dimensions: mm
315
ECOi and ECO G indoor units dimensions F2 Type // Variable Static Pressure Hide Away S-15MF2E5A // S-22MF2E5A // S-28MF2E5A // S-36MF2E5A // S-45MF2E5A // S-56MF2E5A Filter
6 35 32
28
172
26 4
700
Inspection acces 450 x 450 (Field supply)
636
758 700
280
9 3
7 65
300
1
12 - Ø3 holes
71
1 Refrigerant tubing joint (liquid tube) Ø 6.35 flare 2 Refrigerant tubing joint (gas tube) Ø 12.7 flare 3 Upper drain port VP25 Outer diameter 32mm 200 flexible hose supplied 4 Bottom drain port VP 25 O.D. Ø 32mm 5 Suspension lug 4-12 x 30mm 6 Power supply outlet 7 Fresh air intake port Ø 150mm 8 Flange for flexible air outlet duct 9 Electrical component box
150 x 3 = 450 800 867 (Suspension bolt pitch)
5
130 30 20
8
32
30
113
256
89
71 33 (150)
70
23
140
27
186 290
23
2
(75) 154 23
592 (Flange O.D.)
77
186
54
S-60MF2E5A // S-73MF2E5A // S-90MF2E5A Filter
6
172 32
28
35
280
9
26 4
700
636
700
758
3 Inspection acces 450 x 450 (Field supply)
7 65
300
1
21
150 x 5 = 750 1000 1067 (Suspension bolt pitch)
5
130
150 21 33 (150)
70
23
140
27
186 290
23
2
154
186
792 (Flange O.D.)
27
(75) 54
77
1 Refrigerant tubing joint (liquid tube) Ø 9.52 flare 2 Refrigerant tubing joint (gas tube) Ø 15.88 flare 3 Upper drain port VP25 Outer diameter Ø 32mm 200 flexible hose supplied 4 Bottom drain port VP 25 Outer diameter 32mm 5 Suspension lug 4-12 x 30mm 6 Power supply outlet 7 Fresh air intake port Ø 150mm 8 Flange for flexible air outlet duct 9 Electrical component box
16 - Ø3 holes
30 20
8
32
30
113
256
89
Dimensions: mm
316
VRF SYSTEMS
S-106MF2E5A // S-140MF2E5A // S-160MF2E5A Filter
6 35 32
28
172
280
9 26 4
700
Inspection acces 450 x 450 (Field supply)
636
700
758
3
7
71
20 - Ø3 holes
150
150 x 7 = 1050 1400 1467 (Suspension bolt pitch)
1 Refrigerant tubing joint Ø 9.52 flare (liquid) 2 Refrigerant tubing joint Ø 15.88 flare (gas) 3 Upper drain port VP25 O.D. Ø 32mm) 200 flexible hose 54 supplied 4 Bottom drain port VP 25 Outer diameter 32mm 5 Suspension lug 4-12 x 30mm 6 Power supply outlet 7 Fresh air intake port Ø 150mm 8 Flange for flexible air outlet duct 9 Electrical component box
65 130
30 20
8
32
30
113
256
1
300
89 5
71 33 (150)
70
23
140
27
186 290
23
2
(75) 1192 (Flange O.D.)
77
186
27
154
Dimensions: mm
M1 Type // Slim Variable Static Pressure Hide Away Refrigerant tubing joint (narrow tube) Refrigerant tubing joint (wide tube) Upper and bottom drain port Outer diameter 26mm Suspension lug Power supply outlet 2- Ø 30 Flange for air intake duct PL cover Electrical component box Frame filter Signal output board ACC-SG-AGB: optional
145
6
29 692
96 66
2-ø3.1 Hole 28 30
84 10
30
26 27
640 (160 x 4) 5-Ø3.1 Hole
80 143
1 33
2
44
Inspection access (450 x 450) Field supply
153 194
3
37
VIEW A
150
Frame Filter Uninstalled
10
14
14
120
155
150 200
10-Ø3.1 Hole
14
5
22
750 824 (suspension bolt pitch)
40
38
8
126
9
15
11 680
23
640
4
238
81 7
564 (suspension bolt pitch)
1 2 3 4 5 6 7 8 9 10
23
132
220
220 704
132 23 Dimensions: mm
317
ECOi and ECO G indoor units dimensions E2 Type // High Static Pressure Hide Away
178
41
4
106
5
1310 1070 10 x 100P = 1000 28-Ø3.5 (holes all around)
44
1 2 3 4 5 6
51
23
479 300 100 100 50
1 209 2
1100
1230
1170 (suspension bolt pitch)
344
2
224 280 Refrigerant liquid line Ø 9.52 Refrigerant gas line Ø 19.05 Ø 22.22 Power supply outlet Drain port Outer diameter 32 mm Duct connection for suction Duct connection for discharge
6
71
100 100 60 320
26-Ø3.5 (holes all around) 9 x 100P = 900 964 1200 (suspension bolt pitch)
43 67
4 - 37 x 12 (hole for suspension bolt)
67
1310 113 3
42
364
(236) 364 1334 1428
Dimensions: mm
Heat Recovery with DXCoil A PAW-500ZDX2 1,470 PAW-800ZDX2 1,822 PAW-01KZDX2 1,822
A1 1,410 1,752 1,752
A2 1,630 1,986 1,986
B 997 882 1,132
B1 1,053 936 1,186
B2 1,112 994 1,244
D 728 431 681
D1 497 431 532
Ød 200 250 250
E 38 169 169
Electrical case
C
E
Check cover
C 312 390 390
A2 A
Fresh air
D
B2
Fresh air
B
Exhaust air D1
Exhaust air
B1
Ød
A1
Dimensions: mm
318
VRF SYSTEMS
T2 Type // Ceiling S-36MT2E5A // S-45MT2E5A // S-56MT2E5A
123
61
7
190
Drain port VP20 Inside diameter ø26mm, drain hose supplied Left drain position Refrigerant liquid tubing Ø 9.52mm, flare connection Refrigerant gas tubing Ø 15.88mm, flare connection Left side drain hose outlet port (cutout) Tubing hole on wall surface Ø100mm Upper side tubing port Right side drain hose outlet port (cutout) Wireless remote controller receiver installation location
(suspension bolt pitch)
1 2 3 4 5 6 7 8 9
(suspension bolt pitch) 690
1
216
8
Minimum 50cm
Approx. 2°
4
15
1269
5
1275 Service space
Service space Tubing hole position on wall surface (Figure shows view from front)
176
Air intake
Over
Over
Air discharge
96
6 3
(Gas tubing) 70 (Liquid tubing) 90 (Right drain position)
4
(Closed with rubber stopper at time of shipment.) (Left drain position)
S-73MT2E5A // S-106MT2E5A // S-140MT2E5A
123 7
C 690 690
D 1,584 1,269
E 1,541 1,226
265 190 (suspension bolt pitch)
B 235 235
E (suspension bolt pitch) C D
216
4
B Air discharge Air intake
Minimum
A 1,590 1,275
Approx. 2°
106-140 type 140 type
Over
Over A
Service space
Service space Tubing hole position on wall surface (Figure shows view from front)
6 90 (Closed with rubber stopper at time of shipment.) (Left drain position)
3
4
96
(Gas tubing) (Liquid tubing) 90 (Right drain position) Dimensions: mm
319
ECOi and ECO G indoor units dimensions K2/K1 Type // Wall Mounted S-15MK2E5A / S-22MK2E5A / S-28MK2E5A / S-36MK2E5A 870
183
190 2 1
5
5
6
57
Ø70
214
128
Ø70
49
15
57
61
290
290
5
3
128
241.5
241.5 438.5
438.5 4
5
45
5
1 2 3 4 5 6
60
60
Refrigerant tubing (liquid tube) Drain hose Rear panel Refrigerant tubing (gas tube) Rear panel fixing holes Tubing and wiring holes
85
65
95
Ø 6.35 (flared) Outer diameter 16mm PL Back Ø 12.7 (flared)
100
50
Ø 70
S-45MK1E5A / S-56MK1EA5 / S-73MK1E5A / S-106MK1E5A
115.9
115.9
1065
197.4
148.7 2
3 230.7 200
450 95
70
415 448.2 568.2 4
132
(Ø8 0)
5
(2.5)
60
230
415 439.8 496.8
8
60
158
48
(Ø8
0)
300
48
300
37.3
17.9
95
68
384.3 140
1
1 2 3 4 5
320
67
Refrigerant tubing (liquid tube) Refrigerant tubing (gas tube) Drain hose VP13 Rear panel Tubing and wiring holes
67
45-56 73-106 Ø 6.35 (flared) Ø 9.52 (flared) Ø 12.7 (flared) Ø 15.88 (flared) Outer diameter 18mm PL BACK Ø 80
86
75
11
50
50
Dimensions: mm
VRF SYSTEMS
P1 Type // Floor Standing 9
22-36 45 56 71
A
B
C
1,065
665
632
1,380
980
947
Liquid pipes
Gas pipes
Ø 6.35
Ø 12.7
Ø 9.52
Ø 15.88
230
57
15
26
177
161
100
(60.5)
7
C
60.5
2 3 4 5 6 7 8 9
4-Ø 12 hole (For fastening the indoor unit to the floor with screws.) Air filter Refrigerant connection outlet (liquid tube) Refrigerant connection outlet (gas tube) Level adjusting bolt Drain outlet (20 A) Power cord outlet (downward, rear) Refrigerant tubing outlet (downward, rear) Location for mounting the remote controller (Remote controller can be attached within the room.)
109
1
1
B
156
A
138 67
Air outlet
615
4
70
255
110
402
539
3
Air inlet
7
5
(110)
107
2
6 8
205
50
Dimensions: mm
R1 Type // Concealed Floor Standing
D
E
F
56 100
170
Liquid Gas pipes pipes
904 692 672 665 500 86
A 166
229
B
46
125 (Internal dimension)
61
C (Internal dimension)
Ø 6.35 Ø 12.7 F
1,219 1,007 1,002 980 900 51
E (hole pitch=100)
155 66
F 7
Ø 9.52 Ø 15.88
20
85
20
10 20
10
Air outlet
4
402
539
616
3
10
260
C
1
70
22-36 45 56 71
B
D
20
A
184.5
374
2 3 4 5 6 7
4-ø12 hole (For fastening the indoor unit to the floor with screws.) Air filter Refrigerant connection outlet (liquid tube) Refrigerant connection outlet (gas tube) Level adjusting bolt Drain outlet (20 A) Flange for the air-outlet duct
147
1
5
Air inlet
147
2 30 Power supply outlet
(B-60)
30
6
205 Dimensions: mm
321