Preview only show first 10 pages with watermark. For full document please download

Ecoi And Ecog Indoor Units

   EMBED


Share

Transcript

ECOi and ECO G indoor units dimensions U1 Type // 4 Way 90x90 Cassette 745 (suspension bolt pitch) 8 Ø 150 4-12x30 slot Ø 100¹ X 421 1 Air inlet kit is necessary. Filter size: 520 x 520 x 16 106-160 319 187 B 786 (suspension bolt pitch) Ø 6.35 (flared) Ø 9.52 (flared) Ø 12.7 (flared) Ø 15.88 (flared) Outer diameter 32mm 22-90 256 124 167 130 95 Type A B 860~910 (ceiling opening dimension) 130 60-160 860~910 (ceiling opening dimension) 22-56 (411) Type 1 Air intake grill 2 Air discharge outlet 3 Refrigerant piping (liquid pipes) 4 Refrigerant piping (gas pipes) 5 Drain outlet VP50 6 Power supply port 7 Discharge duct 8 Suspension bolt hole 9 Fresh air intake duct connection port 480 7 X VIEW 345 4 3 5 840 840 480 271 50 82 950 514 160 A 42 121 6 7 300 Less than 4-Ø3 g hole Burrin 9 2 18 115 2 Bur 950 4-Ø3 ring hole 515 115 30 670 850 2 Ø16 80 1 3 Ø11 7 2 118 7 95 Less than 35 33.5 160 167 Less than 35 160 50 145 B 180 2 80 Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 30mm or more (18mm or more from the lower surface of the body) as shown in the figure. When the suspension bolt length is long, it hits the ceiling panel and installation is not possible. 2 Dimensions: mm Y2 Type // 4 Way 60x60 Cassette A 650 (ceiling opening dimension) 700 336 530 (suspension bolt pitch) 320 316 301 336 700 212 Panel center 650 (ceiling opening dimension) 7 1 530 (suspension bolt pitch) 2 148 8 A VIEW 2 (583) (583) 575 200 575 170 146 5 71 ø 80 Dimension of Fresh air intake duct (field supply) connection port 314 71 6 ole ing h Barr 4-ø3 4 3 1 2 3 4 5 6 7 8 45 (288) 283 31 (23) 31 112 123 179 260 25 44 Air intake Discharge outlet Refrigerant tubing (liquid tube) Ø 6.35 (flared) Refrigerant tubing (gas tube) Ø 12.7 (flared) Drain tube connection port VP25 Outer dia. Ø 32 Power supply port Suspension bolt hole 4-11 x 26 hole Fresh air intake duct connection port Ø 80 Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 45mm or more, as shown in the figure at right. If the suspension bolts is too long, it will contact the ceiling panel and the unit cannot be installed. Dimensions: mm VRF SYSTEMS L1 Type // 2 Way Cassette Ø 9.52 Ø 15.88 Outer diameter 32mm Inspection panel for drain pump 20 Refrigerant liquid line Refrigerant gas line Drain connection 25 A Power supply entry 3 590 Suspension holes 630 1320 1360 Ceiling opening (1.320 x 640) 1 110 30 Fresh air intake (for Ø 125 duct flange) 80 For discharge duct (2-Ø 150 hole) 70 4 290 70 165 75 195 1 220 310 350 2 1140 4 40 70 20 Inspection panel for ECV, drain pan 530 600 640 Panel Center 680 1 2 3 4 102 8 60 23 680 680 1360 Dimensions: mm 1060 (suspension bolt pitch) e hol .1 Ø3 k-o ut hole ) 20 20 356 200 95 76 61 41 Fresh air intake duct connection port (detail) Required space for installation 6 FRONT VIEW 20 92 112 noc Ø113 1000 1190 (ceiling opening dimension) 154 7 0 (k 4– 710 3 726 706 363 230 Ø10 216 80 4 94 25 20 8 5 10 135 475 (suspension bolt pitch) 220 255 760 (ceiling opening dimension) 28-56 73 Air intake grille Discharge outlet Refrigerant piping (liquid pipes) Ø 6.35 (flared) Ø 9.52 (flared) Refrigerant piping (gas pipes) Ø 12.7 (flared) Ø 15.88 (flared) Drain connection VP25 Outer diameter32 Power supply entry Discharge duct connection port (for descending ceiling) Fresh air intake duct connection port Ø 100 Installation port for wireless remote controller receiver Suspension bolt hole 4–12 30 hole 2 1000 or more 200 or more 9 800 200 or more 1000 or more 200 or more 1000 or more 1 2 3 4 5 6 7 8 9 10 20 D1 Type // 1 Way Cassette 1230 1 Dimensions: mm 315 ECOi and ECO G indoor units dimensions F2 Type // Variable Static Pressure Hide Away S-15MF2E5A // S-22MF2E5A // S-28MF2E5A // S-36MF2E5A // S-45MF2E5A // S-56MF2E5A Filter 6 35 32 28 172 26 4 700 Inspection acces 450 x 450 (Field supply) 636 758 700 280 9 3 7 65 300 1 12 - Ø3 holes 71 1 Refrigerant tubing joint (liquid tube) Ø 6.35 flare 2 Refrigerant tubing joint (gas tube) Ø 12.7 flare 3 Upper drain port VP25 Outer diameter 32mm 200 flexible hose supplied 4 Bottom drain port VP 25 O.D. Ø 32mm 5 Suspension lug 4-12 x 30mm 6 Power supply outlet 7 Fresh air intake port Ø 150mm 8 Flange for flexible air outlet duct 9 Electrical component box 150 x 3 = 450 800 867 (Suspension bolt pitch) 5 130 30 20 8 32 30 113 256 89 71 33 (150) 70 23 140 27 186 290 23 2 (75) 154 23 592 (Flange O.D.) 77 186 54 S-60MF2E5A // S-73MF2E5A // S-90MF2E5A Filter 6 172 32 28 35 280 9 26 4 700 636 700 758 3 Inspection acces 450 x 450 (Field supply) 7 65 300 1 21 150 x 5 = 750 1000 1067 (Suspension bolt pitch) 5 130 150 21 33 (150) 70 23 140 27 186 290 23 2 154 186 792 (Flange O.D.) 27 (75) 54 77 1 Refrigerant tubing joint (liquid tube) Ø 9.52 flare 2 Refrigerant tubing joint (gas tube) Ø 15.88 flare 3 Upper drain port VP25 Outer diameter Ø 32mm 200 flexible hose supplied 4 Bottom drain port VP 25 Outer diameter 32mm 5 Suspension lug 4-12 x 30mm 6 Power supply outlet 7 Fresh air intake port Ø 150mm 8 Flange for flexible air outlet duct 9 Electrical component box 16 - Ø3 holes 30 20 8 32 30 113 256 89 Dimensions: mm 316 VRF SYSTEMS S-106MF2E5A // S-140MF2E5A // S-160MF2E5A Filter 6 35 32 28 172 280 9 26 4 700 Inspection acces 450 x 450 (Field supply) 636 700 758 3 7 71 20 - Ø3 holes 150 150 x 7 = 1050 1400 1467 (Suspension bolt pitch) 1 Refrigerant tubing joint Ø 9.52 flare (liquid) 2 Refrigerant tubing joint Ø 15.88 flare (gas) 3 Upper drain port VP25 O.D. Ø 32mm) 200 flexible hose 54 supplied 4 Bottom drain port VP 25 Outer diameter 32mm 5 Suspension lug 4-12 x 30mm 6 Power supply outlet 7 Fresh air intake port Ø 150mm 8 Flange for flexible air outlet duct 9 Electrical component box 65 130 30 20 8 32 30 113 256 1 300 89 5 71 33 (150) 70 23 140 27 186 290 23 2 (75) 1192 (Flange O.D.) 77 186 27 154 Dimensions: mm M1 Type // Slim Variable Static Pressure Hide Away Refrigerant tubing joint (narrow tube) Refrigerant tubing joint (wide tube) Upper and bottom drain port Outer diameter 26mm Suspension lug Power supply outlet 2- Ø 30 Flange for air intake duct PL cover Electrical component box Frame filter Signal output board ACC-SG-AGB: optional 145 6 29 692 96 66 2-ø3.1 Hole 28 30 84 10 30 26 27 640 (160 x 4) 5-Ø3.1 Hole 80 143 1 33 2 44 Inspection access (450 x 450) Field supply 153 194 3 37 VIEW A 150 Frame Filter Uninstalled 10 14 14 120 155 150 200 10-Ø3.1 Hole 14 5 22 750 824 (suspension bolt pitch) 40 38 8 126 9 15 11 680 23 640 4 238 81 7 564 (suspension bolt pitch) 1 2 3 4 5 6 7 8 9 10 23 132 220 220 704 132 23 Dimensions: mm 317 ECOi and ECO G indoor units dimensions E2 Type // High Static Pressure Hide Away 178 41 4 106 5 1310 1070 10 x 100P = 1000 28-Ø3.5 (holes all around) 44 1 2 3 4 5 6 51 23 479 300 100 100 50 1 209 2 1100 1230 1170 (suspension bolt pitch) 344 2 224 280 Refrigerant liquid line Ø 9.52 Refrigerant gas line Ø 19.05 Ø 22.22 Power supply outlet Drain port Outer diameter 32 mm Duct connection for suction Duct connection for discharge 6 71 100 100 60 320 26-Ø3.5 (holes all around) 9 x 100P = 900 964 1200 (suspension bolt pitch) 43 67 4 - 37 x 12 (hole for suspension bolt) 67 1310 113 3 42 364 (236) 364 1334 1428 Dimensions: mm Heat Recovery with DXCoil A PAW-500ZDX2 1,470 PAW-800ZDX2 1,822 PAW-01KZDX2 1,822 A1 1,410 1,752 1,752 A2 1,630 1,986 1,986 B 997 882 1,132 B1 1,053 936 1,186 B2 1,112 994 1,244 D 728 431 681 D1 497 431 532 Ød 200 250 250 E 38 169 169 Electrical case C E Check cover C 312 390 390 A2 A Fresh air D B2 Fresh air B Exhaust air D1 Exhaust air B1 Ød A1 Dimensions: mm 318 VRF SYSTEMS T2 Type // Ceiling S-36MT2E5A // S-45MT2E5A // S-56MT2E5A 123 61 7 190 Drain port VP20 Inside diameter ø26mm, drain hose supplied Left drain position Refrigerant liquid tubing Ø 9.52mm, flare connection Refrigerant gas tubing Ø 15.88mm, flare connection Left side drain hose outlet port (cutout) Tubing hole on wall surface Ø100mm Upper side tubing port Right side drain hose outlet port (cutout) Wireless remote controller receiver installation location (suspension bolt pitch) 1 2 3 4 5 6 7 8 9 (suspension bolt pitch) 690 1 216 8 Minimum 50cm Approx. 2° 4 15 1269 5 1275 Service space Service space Tubing hole position on wall surface (Figure shows view from front) 176 Air intake Over Over Air discharge 96 6 3 (Gas tubing) 70 (Liquid tubing) 90 (Right drain position) 4 (Closed with rubber stopper at time of shipment.) (Left drain position) S-73MT2E5A // S-106MT2E5A // S-140MT2E5A 123 7 C 690 690 D 1,584 1,269 E 1,541 1,226 265 190 (suspension bolt pitch) B 235 235 E (suspension bolt pitch) C D 216 4 B Air discharge Air intake Minimum A 1,590 1,275 Approx. 2° 106-140 type 140 type Over Over A Service space Service space Tubing hole position on wall surface (Figure shows view from front) 6 90 (Closed with rubber stopper at time of shipment.) (Left drain position) 3 4 96 (Gas tubing) (Liquid tubing) 90 (Right drain position) Dimensions: mm 319 ECOi and ECO G indoor units dimensions K2/K1 Type // Wall Mounted S-15MK2E5A / S-22MK2E5A / S-28MK2E5A / S-36MK2E5A 870 183 190 2 1 5 5 6 57 Ø70 214 128 Ø70 49 15 57 61 290 290 5 3 128 241.5 241.5 438.5 438.5 4 5 45 5 1 2 3 4 5 6 60 60 Refrigerant tubing (liquid tube) Drain hose Rear panel Refrigerant tubing (gas tube) Rear panel fixing holes Tubing and wiring holes 85 65 95 Ø 6.35 (flared) Outer diameter 16mm PL Back Ø 12.7 (flared) 100 50 Ø 70 S-45MK1E5A / S-56MK1EA5 / S-73MK1E5A / S-106MK1E5A 115.9 115.9 1065 197.4 148.7 2 3 230.7 200 450 95 70 415 448.2 568.2 4 132 (Ø8 0) 5 (2.5) 60 230 415 439.8 496.8 8 60 158 48 (Ø8 0) 300 48 300 37.3 17.9 95 68 384.3 140 1 1 2 3 4 5 320 67 Refrigerant tubing (liquid tube) Refrigerant tubing (gas tube) Drain hose VP13 Rear panel Tubing and wiring holes 67 45-56 73-106 Ø 6.35 (flared) Ø 9.52 (flared) Ø 12.7 (flared) Ø 15.88 (flared) Outer diameter 18mm PL BACK Ø 80 86 75 11 50 50 Dimensions: mm VRF SYSTEMS P1 Type // Floor Standing 9 22-36 45 56 71 A B C 1,065 665 632 1,380 980 947 Liquid pipes Gas pipes Ø 6.35 Ø 12.7 Ø 9.52 Ø 15.88 230 57 15 26 177 161 100 (60.5) 7 C 60.5 2 3 4 5 6 7 8 9 4-Ø 12 hole (For fastening the indoor unit to the floor with screws.) Air filter Refrigerant connection outlet (liquid tube) Refrigerant connection outlet (gas tube) Level adjusting bolt Drain outlet (20 A) Power cord outlet (downward, rear) Refrigerant tubing outlet (downward, rear) Location for mounting the remote controller (Remote controller can be attached within the room.) 109 1 1 B 156 A 138 67 Air outlet 615 4 70 255 110 402 539 3 Air inlet 7 5 (110) 107 2 6 8 205 50 Dimensions: mm R1 Type // Concealed Floor Standing D E F 56 100 170 Liquid Gas pipes pipes 904 692 672 665 500 86 A 166 229 B 46 125 (Internal dimension) 61 C (Internal dimension) Ø 6.35 Ø 12.7 F 1,219 1,007 1,002 980 900 51 E (hole pitch=100) 155 66 F 7 Ø 9.52 Ø 15.88 20 85 20 10 20 10 Air outlet 4 402 539 616 3 10 260 C 1 70 22-36 45 56 71 B D 20 A 184.5 374 2 3 4 5 6 7 4-ø12 hole (For fastening the indoor unit to the floor with screws.) Air filter Refrigerant connection outlet (liquid tube) Refrigerant connection outlet (gas tube) Level adjusting bolt Drain outlet (20 A) Flange for the air-outlet duct 147 1 5 Air inlet 147 2 30 Power supply outlet (B-60) 30 6 205 Dimensions: mm 321