Preview only show first 10 pages with watermark. For full document please download

Econoline Features Dc/dc-converter Unregulated

   EMBED


Share

Transcript

● ● ● ● ● ● ● Features Unregulated Converter Industry Standard Pinout 1kVDC or 2kVDC Isolation UL94V-0 Package Material Optional Continuous Short Circuit Protected Fully Encapsulated Custom Solutions Available Efficiency to 85 % ECONOLINE DC/DC-Converter with 3 year Warranty The RO DC/DC converters are typically used in general purpose power isolation and voltage matching applications, and feature a full industrial operating temperature range of -40°C to +85°C without derating. Description 1 Watt SIP4 Single Output Selection Guide Part Number SIP 4 Output Voltage (VDC) Output Current (mA) Efficiency (2kV) Input Voltage (VDC) (%) Max. Capacitive Load(1) RO-xx3.3S (H) 3.3, 5, 12, 15, 24 3.3 303 75 2200µF RO-xx05S (H) 3.3, 5, 12, 15, 24 5 200 78-80 1000µF RO-xx09S (H) 3.3, 5, 12, 15, 24 9 111 78-80 1000µF RO-xx12S (H) 3.3, 5, 12, 15, 24 12 83 80-84 470µF RO-xx15S (H) 3.3, 5, 12, 15, 24 15 66 80-84 470µF RO-xx24S (H) 3.3, 5, 12, 15, 24 24 42 78-85 xx = Input Voltage (other input and output voltage combinations available on request) 220µF RoHS 2011/65/EU 6/6 * add Suffix “P” for Continuous Short Circuit Protection, e.g. RO-0505S/P, RO-0505S/HP EN-60950-1 Certified UL-60950-1 Certified EN-60601-1 Certified* Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up) Input Voltage Range ±10% Output Voltage Accuracy ±5% Line Voltage Regulation 3.3V output type 20% max. (10% to 100% full load) 5V output type 15% max. 9V, 12V, 15V, 24V output types 10% max. Output Ripple and Noise (20MHz limited) RO 100mVp-p max. 50kHz min. / 100kHz typ. / 105kHz max. Efficiency at Full Load 70% min. / 80% typ. Minimum Load = 0% Specifications valid for 10% minimum load only. Isolation Voltage (tested for 1 second) 1000VDC (rated for 1 minute**) 500VAC / 60Hz H-Suffix (tested for 1 second) 2000VDC H-Suffix (rated for 1 minute**) 20pF min. / 75pF max. Isolation Resistance P-Suffix 1 Second 80 Continuous 60 -40°C to +85°C (see Graph) Storage Temperature Range -55°C to +125°C Relative Humidity 95% RH Package Weight 1.4g Packing Quantity 42 pcs per Tube } 100 10 GΩ min. Short Circuit Protection MTBF (+25°C) Detailed Information see (+85°C) Application Notes chapter "MTBF" (Ambient Temperature) 1000VAC / 60Hz Isolation Capacitance Operating Temperature Range (free air convection) Derating-Graph using MIL-HDBK 217F 985 x 103 hours using MIL-HDBK 217F 200 x 103 hours Output Power (%) Operating Frequency Isolation Voltage (*/H suffix) 1.2%/1% of Vin typ. Load Voltage Regulation E-358085 40 30 20 0 Safe Operating Area -40 0 50 85 Operating Temperature °C 100 150 continued on next page **Any data referred to in this datasheet are of indivative nature and based on our practical experience only. For further details, please refer to our Application Notes. www.recom-international.com REV: 0/2014 Refer to Application Notes E-37 RO Series ECONOLINE DC/DC-Converter Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up) Certifications CB Test Report Report: US/15348/UL UL General Safety Report: E358085 IEC 60950-1:2005 2nd Ed. EN General Safety Report: SPCLVD1109103 EN Medical Safety Report: MDD1112018 + RM1112018 UL 60950-1 2nd Ed. EN60950-1:2006 + A12:2011 IEC/EN 60601-1 3rd Edition Medical Report + ISO14971 Risk Assessment Notes Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter. Typical Characteristics RO-xx05S RO-xx15S RO-xx12S Efficiency / Load 1205 3.305 80 0% 20% 40% 60% Total Output current (%) 80% 100% Efficiency % 20 0 0% 40% 20% 80% 60% 0 100% 5.000 1205 -5.000 -10.000 0% 20% 40% 60% Total Output current (%) 80% 100% 0512 15.000 Deviation from Nominal (%) 10.000 0.000 20.000 20.000 Deviation from Nominal (%) Deviation from Nominal (%) RO 15.000 1212 10.000 5.000 0.000 3.312 -5.000 -10.000 60% 80% 100% 25.000 25.000 0505 40% 20% Deviation / Load Deviation / Load 3.305 0% Total Output current (%) Total Output current (%) 20.000 3.315 20 Deviation / Load 25.000 0515 40 3.312 40 20 Efficiency % Efficiency % 60 60 0505 1215 80 1212 0512 80 40 100 100 60 0 Efficiency / Load Efficiency / Load 100 0% 20% 40% 60% Total Output current (%) 80% 0515 15.000 3.315 10.000 5.000 0.000 1215 -5.000 -10.000 100% 0% 20% 40% 60% Total Output current (%) 80% 100% Package Style and Pinning (mm) 4 PIN SIP Package 10.00 RECOM RO-0505S **** 4.10 6.00 0.51 typ. RECOM RO-0505S **** 0.51 typ. 1 2 3 4 Recommended Footprint Details 11.50 0.25 1.9 Bottom View 7.62 2.54 1.00 ø+0.15/–0 1.27 RO Pin Connections Pin # Single 1 –Vin 2 +Vin 3 –Vout 4 +Vout Top View 2.54 XX.X ± 0.5 mm XX.XX ± 0.25 mm The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications. The Buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or damage property. E-38 REV: 0/2014 www.recom-power.com