Preview only show first 10 pages with watermark. For full document please download

Edid 101 Setup Guide

   EMBED


Share

Transcript

EDID 101 Setup Guide POWER 12V 0.4A MAX DVI INPUT (SOURCE) ON 1 2 DVI OUTPUT (DISPLAY) RECORD 60 DIGITAL Hz SIGNAL 50 ANALOG EDID SELECT This guide provides basic instructions for an experienced installer to operate and install the EDID 101. Where possible in the following pages, line drawings and photos from an actual installation are used to clarify steps discussed in the text. Where appropriate, images have one or more numbers corresponding to a specific instruction described. The Extron EDID 101 is a standalone EDID Minder™ device that emulates EDID (Extended Display Identification Data) to a DVI (101D) or VGA (101V) source. It helps ensure the video source boots up correctly and constantly outputs video. Step 1 — Configure the EDID 101 The EDID 101 should be configured prior to installation as it may be difficult to access after mounting or placing in the system. EDID can be recorded from a display or a pre-programmed EDID can be selected from Table 1. To record and use a user recorded EDID (rotary switch position 0) a. Turn the rotary switch (b) to position 0. N The DIP switch positions have no effect in this mode. b a ON b. Apply power to the EDID 101 by connecting a power source. If power is not available from a video source, an external 12 VDC power supply can be used. The green LED will be lit when power is available. c. Connect the display device to the output of the EDID 101. d. Power on the display device. N Although the EDID 101 supplies 5 VDC to power the EDID circuitry of a display device, the display power should be on to ensure that data is being transmitted during the recording process. e. Press and hold the recessed record button (a) until the LED flashes red rapidly, then release the button. The LED continues to flash red, then returns to steady green when the EDID data has been stored. The display can now be disconnected. N If an external power supply was used, it can now be disconnected. f. The EDID 101 has now been configured. Continue to Step 2. To use a pre-programmed Extron EDID (rotary switch positions 1-F) N Configuring the EDID 101 rotary and DIP switches allow a user to select a pre-programmed EDID based on the native rate of a display (i.e. 1280x1024 @ 60 Hz) and signal type (i.e. digital), but does not necessarily force a video source to output that rate. Since EDID is not limited to reporting a single video rate (i.e. the native rate), each Extron EDID also lists other common video rates for use by the video source. a. Choose a resolution from table 1 based on the native resolution of the display device. Note the corresponding rotary switch position. b. Set the the rotary switch (b) to the position (1-F) selected previously. The switch will click as each position is selected. N When using a dual link DVI display with the EDID 101D, (position F), two resolutions will be shown to the source, 1280x800 and 2560x1600. 1 2 RECORD Rotary Switch Position 60 DIGITAL Hz SIGNAL 50 ANALOG EDID SELECT Resolution 0 user recorded EDID 1 800x600 2 1024x768 3 1280x720 4 1280x768 5 1280x800 6 1280x1024 7 1360x768 8 1366x768 9 1400x1050 A 1440x900 B 1600x1200 C 1680x1050 D 1920x1080 E 1920x1200 F Digital: Dual Link Analog: Not used Table 1 — Rotary Switch position 68-1773-50 Rev. A 06 09 EDID 101 Setup Guide, Continued c. Set the first DIP switch to the desired vertical frequency (default is ON, 60 Hz). d. For the EDID 101D, set the second DIP switch to the DVI input signal format, digital or analog. The switch is not used on the EDID 101V. e. The EDID 101 has now been configured for the selected parameters. Continue to step 2. 60 ON DIGITAL SIGNAL Hz 50 1 2 ANALOG Step 2 — Mount the EDID 101 The small footprint of the EDID 101 and the ability to be powered through DVI or VGA cables connected to a PC or laptop simplify installation. Mount the device as required. Step 3 — Connect the EDID 101 a. Connect a DVI (101D) or VGA (101V) cable from the source to the EDID 101 input. b. Connect a DVI (101D) or VGA (101V) cable from the EDID 101 output to the display or distribution system. N The EDID 101 is a pass-through device and should be located as close to the input source as possible. The total length of DVI cabling, including input and output cables, connected to the EDID 101D should not exceed maximum recommended lengths for standard DVI applications. DVI Cable 6’ max. I DV 2 DA I DV UT TP IN OU PU T (S OU ID D E Extron DVI DA2 DVI Distribution Amplifier RC 1D 10 UT TP E) L OU CA LO T PU IN G Y) LA I DV NFI TS OR PP LY SU ON I-D DV CO ISP (D UT TP OU Y) LA ISP U TP I-D DV R WE PO V 12 MAX A T (D OU 0.4 Extron EDID 101D EDID Minder PC LCD Flat Panel Display LCD Flat Panel Display 2 1 4 3 2 L R L 232 RS R 1 DIO S AU UT TP OU L V R DIO AU UTS INP H B G 1 R 2 1 V H HV V 4 3 HV HV S UT TP OU 2 ON H B G 3 R V H 4 S UT INP B 1.5A G 1 MAX R 2 Extron Crosspoint 300 42 HVA 0Hz 50-6 240V 100- Projector Wideband Matrix Switcher Flat Panel Display VGA INP UT ID D E UR (SO CE) 1D 10 VGA INP ID D UT (SO UR 10 1D CE) Y) PLA PUT VGA E Y) PLA T (DIS TPU OU VGA (DIS OUT Y) PLA T (DIS TPU Y) PLA OU PC VGA Extron EDID 101V EDID Minder PUT VGA Laptop Step 4 — Confirm power (DIS OUT Extron EDID 101V EDID Minder Turn on the video source. When the DVI or VGA source is on, the EDID 101 LED lights green, indicating power is being received. N During normal operation the EDID 101 can be powered using +5 VDC from pin 9 of a DDC compliant VGA source (101V) or pin 14 of a DVI source (101D). Extron USA - West Headquarters +800.633.9876 Inside USA / Canada Only +1.714.491.1500 +1.714.491.1517 FAX Extron USA - East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East +800.633.9876 +800.3987.6673 +800.7339.8766 +81.3.3511.7655 +81.3.3511.7656 FAX +400.883.1568 +971.4.2991800 +971.4.2991880 FAX +1.919.863.1794 +1.919.863.1797 FAX +31.33.453.4040 +31.33.453.4050 FAX +65.6383.4400 +65.6383.4664 FAX Inside USA / Canada Only Inside Europe Only Inside Asia Only © 2009 Extron Electronics. All rights reserved. Inside China Only +86.21.3760.1568 +86.21.3760.1566 FAX