Preview only show first 10 pages with watermark. For full document please download

Editor_gvg100(4802dr

   EMBED


Share

Transcript

GVG100 Setup This protocol was tested with Carbonite version 5.0. Cable Connections A GVG100 Editor can connect to the switcher either directly using an RS-422 connection, or through an RS-422 to RS-232 converter or a Comtrol® DeviceMaster®. For information on connecting using a DeviceMaster®, refer to the DeviceMaster® Setup Sheet. 4. Use the Type knob to select Editor. 5. Press NEXT. 6. Use the SubType knob to select the GVG100 command set you want to use. • GVG100L_1.0 — supports the legacy set of GVG100 editor commands • GVG100_1.0 — supports the custom Ross Video superset of GVG100 editor commands 7. Press the SubType knob. 8. Press the Confrm knob. Cable Connections Serial Interface Cables are used to connect the switcher to the editor, either directly or though the RS-232/422 converter. Figure 1: RJ-45 Connector Table 1: Cable Connections GVG100 Editor Setup Refer to the documentation that came with your editor for information on setting up your editor to communicate with the switcher. To communicate with the switcher, you must use the following communication settings: • 38.4k Baud • 8 Data Bits • 1 Stop Bit • Odd Parity Carbonite (Serial Port) 1 (Tx+) 2 (Tx-) 3 (Rx+) 6 (Rx-) 7,8 (Gnd) Switcher Setup To Set Up Communications 1. Press MENU > SYSTEM > NEXT > NEXT > Device Config. 2. Press the Add knob. If you are editing, or deleting, an existing device, use the Add knob to select the device and press the Edit, or Delete, knob. 3. Use the Slot knob to select SP. 4802DR-606 Rev.3