Preview only show first 10 pages with watermark. For full document please download

Edwards 870-871

   EMBED


Share

Transcript

HORNS & SIRENS AdaptaHorn® Flush Mount Vibrating Horn Indoor Applications 870 & 871 Series www.leedan.com FEATURES > PLC compatible models > Corrosion resistant finish > Volume adjustable > Completely assembled AGENCY APPROVALS > UL Listed [email protected] Toll-Free: 800-231-1414 The Edwards 870 AC & 871 DC Series are low-current, high decibel flush mount vibrating horns for heavy-duty use. It has been designed for wall or panel installation and projects less than 1" (25mm) from the mounting surface. Supplied complete with trim plate. Designed for indoor installation. Horn mounts in Catalog No. 870-B back box (ordered separately). > FM Approved (870 Series) Applications include ceiling and wall mounting in corridors and manufacturing sites. Also, ideal for scoreboards. Used wherever a SPECIFICATIONS distinctive, urgent signal is required for timing, scheduling, paging, > Operating range: -20% to +10% of nominal voltage > Heavy duty die-cast housing 870 AC Series general alarm, and warning. 872-PO Plastic Projector AdaptaHorn Accessory Plastic projector snaps onto any > Adjustable output: 78 to 103 dB AdaptaHorn. Available as separate item. > 400 hour rating at 50% duty cycle 871 DC Series > Adjustable output: 78 to 101 dB 6-6 D-04 > 200 hour rating 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards HORNS & SIRENS TECHNICAL INFORMATION 11/16" (17mm) 4 1/2" (114mm) 6 1/2" (165mm) 2 1/4" (57mm) Volume adjustment set screw 1/16" (2mm) allen wrench supplied Cat. No. Volts Amps VA DC coil Res. (Ohms) dB at 10 Ft. 870-G5 870-N5† 870-R5 24V AC 120V AC 240V AC .63 .13 .07 15.1 15.6 16.8 5.2 150 580 103 871-E1 871-G1 871-K1 871-P1 871-S1 12V DC 24V DC 48V DC 125V DC 250V DC .27 .16 .07 .025 .014 3.2 3.8 3.4 3.1 3.5 6.0 24 96 600 2640 † 101 Diode Polarized version available in red, order 880D-N5. PLC COMPATIBILITY - SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. Operating voltage Volts Max. off state leakage current mA Continuous on current mA Surge (inrush/duration) Amps/milliseconds 870-N5 120V AC 60 Hz 25 120 1.02/.000026 871-G1 24V DC 25 150 1.7/.000042 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. Electromechanical devices can produce transient spikes and should only be used on PLC output cards that have inherent transient spike suppression. Consult the PLC manufacturer prior to connecting 24V DC electromechanical devices to PLCs. D-04 www.leedan.com [email protected] Toll-Free: 800-231-1414 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 6-7 © Copyright 2004 Edwards