Transcript
EFA25*1C, EFA25K*1C, EFA25*2C, EFA25*3C ® With FLEXI-GUARD
Installation/Care/Use Manual Manual de Instalación/Cuidado/Utilización Manuel dinstallation/entretien/utilisation USES HFC-134A REFRIGERANT USA REFRIGERANTE HFC-134A UTILISE DU FLUIDE FRIGORIGÈNE HFC-134A SEE FIG.4 VEA LA FIG.4 VOIR FIG.4
SEE FIG.5 VEA LA FIG.5 VOIR FIG.5
7
24
30 31 & 32
33 40 27 & 28
13 26
29 14
15 &16
17, 18, 19, & 20
22, 23, & 25
35 & 36
21
34
39
FIG. 1 PAGE 1
97033C (Rev. E - 6/01)
97033C (Rev. E - 6/01)
PAGE 2 E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL. ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE LENCEINTE ET LE MUR. F = POWER CORD 4 FEET (1219mm) LONG CABLE ELÉCTRICO DE 4 PIE (1219mm), DE LARGO CORDON DALIMENTATION 4' (1219mm) G = PLUMBING ROUGH-IN CAN BE LOCATED ANYWHERE WITHIN THIS AREA. SE PUEDE COLOCAR EL DESBASTE DE LA TUBERÍA EN CUALQUIER LUGAR DENTRO DE ESTA ÁREA. ON PEUT PLACER LA TUYAUTERIE DANS CETTE RÉGION.
FIG. 2
LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 IN. (38mm) OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-1/2" (38mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS. EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E. CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼ DE DIÁMETRO. EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU. C = 1-1/4 TRAP NOT FURNISHED** PURGADOR DE 1¼ NO PROPORCIONADO** SIPHON 1-1/4 NON FOURNI** D = ELECTRICAL OUTLET LOCATION UBICACIÓN DE LA TOMA DE ELECTRICIDAD EMPLACEMENT DE LA PRISE DE COURANT
FINISHED FLOOR PISO ACABADO PLANCHER FINI
EFA25*1C, EFA25K*1C, EFA25*2C, EFA25*3C
EFA25*1C, EFA25K*1C, EFA25*2C, EFA25*3C 7 When provided Cuando es proporcionado Si fourni
2 1
6 4
3
FIG. 3
®
DESIGN 2000 FILTER PARTS LIST (See Fig. 3) ITEM NO.
PART NO.
DESCRIPTION
1 2 3 4 5 6 7
51294C 70792C 70823C 70822C 51299C 70818C 22490C
Filter Head Assy Screw #8-18 X .75 PH Fitting - Superseal 3/8 (10mm) Fitting - Superseal 1/4 (6mm) Filter Assy Elbow - 3/8 (10mm) Bracket
5
LISTA DE PIEZAS DEL FILTRO (Vea la Fig. 3)
LISTE DES PIÈCES DU FILTRE (Voir Fig. 3)
DESCRIPCIÓN
DESCRIPTION
Ensamblado de la Cabeza del Filtro Tornillo #8-18 x .75 PH Accesorio - Supersello 3/8" (10mm) Accesorio - Supersello 1/4" (6 mm) Ensamblado del Filtro Codo - 3/8" (10 mm) Fijador
Ens. de tête de filtre Vis #8-18 x ,75 hp Raccord - Superseal 3/8" (10mm) Raccord - Superseal 1/4" (6mm) Ens. filtre Coude - 3/8" (10mm) Support
Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, remove items 2 and adjust screw on item 4. Clockwise adjustment will raise stream and counter-clockwise adjustment will lower stream. For best adjustment, stream should hit basin approximately 6-1/2" (165mm) from bubbler. La altura del chorro se determina en la fábrica a 35 PSI. Si la presión del suministro varía demasiado de este valor, ajuste el tornillo, sacando los Artículos 2, y ajuste el tornillo en el Artículo 4. El ajuste en el sentido de las agujas del reloj elevará el chorro y contra el sentido de las agujas del reloj lo bajará. Para un mejor ajuste, el chorro deberá pegar en el estanque a una distancia de aproximadamente 6½ (165mm) del borboteador.
10
8
9
11
BASIN ESTANQUE BASSIN
Le niveau découlement est réglé en usine à 35 PSI. Si la pression varie beaucoup de ce point, retirez les articles 2 et ajustez la vis de larticle 4. Si vous ajustez dans le sens des aiguilles dune montre, le jet augmentera et dans le sens contraire, le jet diminuera. Le meilleur ajustement est lorsque le jet frappe le bassin à environ 6-1/2" (165mm) du barboteur.
2
1
BASIN ESTANQUE BASSIN
5
12 NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN NUT (ITEM 12) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER TIGHTEN.
6
NOTA: CUANDO SE INSTALE EL BORBOTEADOR DE REPUESTO Y EL PEDESTAL, APRIETE LA TUERCA (ARTICULO 12) SOLAMENTE PARA SOSTENER LAS PIEZAS EN SU POSICIÓN. NO APRIETE EMASIADO.
38
37
3
NOTE: LORSQUE VOUS INSTALLEZ UN NOUVEAU BARBOTEUR ET SOCLE, RESSERREZ LÉCROU (ARTICLE 12) SEULEMENT SUFFISAMMENT POUR GARDER LES PIÈCES BIEN EN PLACE. NE PAS TROP SERRER.
4
FIG. 4 COLOR TABLE PANEL COLOR Stainless Steel
TABLA DE LOS COLORES COLOR DEL PANEL
TABLE DE COULEURS COULEUR DU PANNEAU
Acier inoxydable
Acero inoxidable
FIG. 5 RIGHT PANEL (w/ hole) PANEL DERECHO (sin aguero) PANNEAU DROIT (sans trou) 20625C
PAGE 3
LEFT PANEL RIGHT PANEL (w/o hole) PANEL DERECHO (con aguero) PANEL IZQUIERDO PANNEAU GAUCHE PANNEAU DROIT (avec trou) 27652C
20624C
FRONT PANEL PANEL FRONTAL PANNEAU AVANT 20654C
97033C (Rev. E - 6/01)
EFA25*1C, EFA25K*1C, EFA25*2C, EFA25*3C PARTS LIST 115V/LISTA DE PIEZAS 115V/LISTE DE PIÈCES 115V ITEM NO.
PART NO.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22* 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 NS
45663C 45662C 15005C 61313C 40045C 50986C 20776C 51349C 40322C 50934C 50168C 75580C 35892C 35918C 66479C 27396C 35914C 30502C 41991000 70018C 66204C 35922C 30810C 30263C 35921C 50368C 30235C 55996C 45678C 55909C 66481C 66480C 70767C 70772C 22540C 27398C 100806740570 19037000 56033C 70022C 50930C 27961C 56092C
ITEM NO.
PART. NO.
14 17 22* 23
35919C 35915C 35943C 35879C 35866C 35942C
ITEM NO.
PART. NO.
14 17 22* 23
35919C 35915C 35924C 30811C 30263C 35931C
DESCRIPTION Sleeve Push Button Button Regulator Retaining Nut Regulator Hex Nut Regulator Holder Basin Bubbler Assy Orifice Assy Housing Bubbler Pedestal Bubbler Locknut Cold Control Power Cord Condenser Fan Shroud Fan Motor Fan Blade Fan Bracket Fan Blade Nut Drier Compressor Serv. Pak Overload Relay Capacitor Receptor Drain Cover - Shield Strainer Precooler Assy Tailpipe Helix Heat Exchanger Evaporator Evaporator Retaining Clip Evaporator Drain Plug Shelf - Elkay Deluxe Assy - Baseplate Grommet - Compressor Mtg. Clip - Compressor Mtg Washer Screw - Set Bumper - Rubber Brkt - Strain Relief Tubing Poly (Cut to Length)
DESCRIPCIÓN Manguito pulsador Botón Tuerca retentora del regulador Regulador Tuerca exagonal Portaregulador Estanque Ensamblado del borboteador Ensamblado del orificio Ensamblado del la caja Pedestal Tuerca de enllave Control de frío Cable eléctrico Condensador Cubierta del abanico Motor del abanico Aspa del abanico Fijador del abanico Tuerca del aspa del abanico Secador Paquete de servicio del compresor Sobrecarga Relé Capacitor Desagüe Receptor Cubierta-Terminal Filtro bifurcado Ensamblado del Pre-enfriador Hélice del tubo de escape Intercambiador de calor Evaporador Brida retentora del evaporador Tapón de desagüe del evaporador Repisa Elkay de lujo Conjunto de placa de asiento Arandela Aislante-Mtg del Compresor Traba - Mtg. Compresor Arandela Tornillo de fijación Tope de goma Brkt - el Alivio del Esfuerzo La tubería Asta (el Corte a la Longitud)
DESCRIPTION Manchon bouton poussoir Bouton Écrou de serrage du régleur Régleur Écrou hex. Porte régleur Bassin Ens. barboteur Ens. orifice Ens. boîtier Socle Contre-écrou de barboteur Commande froide Cordon dalimentation Condensateur Carénage de ventilateur Moteur du ventilateur Pale du ventilateur Support du ventilateur Écrou de la pale du vent. Déshydrateur Trousse dentr. surpresseur Ens. surcharge Relais Capaciteur Couvercle - boîte Écran électrique Grille Montage du prérefroidisseur Hélice de tuyère Échangeur thermique Évaporateur Pince de rétention de lévaporateur Bonde de lévaporateur Étagére Elkay de luxe Ensemble plaque de base Anneau - montage du surpresseur Pince - montage du surpresseur Rondelle Vis de blocage Butée caoutchouc Brkt - le Serre-câble Les tuyaux Poteau (la Coupure à la Longueur)
220v/50Hz PARTS LIST/LISTA DE PIEZAS/LISTE DE PIÈCES DESCRIPTION Power Cord Fan Motor Compressor Serv. Pak Overload Relay Capacitor
DESCRIPCIÓN
DESCRIPTION
Cable eléctrico Motor del abanico Paquete de servicio del compresor Sobrecarga Relé Capacitor
Cordon dalimentation Moteur du ventilateur Trousse dentr. surpresseur Ens. surcharge Relais Capaciteur
220v/60Hz PARTS LIST/LISTA DE PIEZAS/LISTE DE PIÈCES DESCRIPTION Power Cord Fan Motor Compressor Serv. Pak Overload Relay Capacitor
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.
PRINTED IN U.S.A. IMPRESO EN LOS E.E.U.U. IMPRIMÉ AUX É.-U.
DESCRIPCIÓN Cable eléctrico Motor del abanico Paquete de servicio del compresor Sobrecarga Relé Capacitor
*INCLUYE RELÉ Y SOBRECARGA. SI ESTÁ BAJO GARANTÍA, REEMPLACE CON EL MISMO COMPRESOR USADO EN EL ENSAMBLADO INICIAL. NOTA: Toda la correspondencia relacionada con el enfriador de agua anterior o con una orden de reparación piezas DEBERÁ incluir el número de modelo y número de serie del enfriador, el nombre y número de pieza de la pieza de repuesto.
DESCRIPTION Cordon dalimentation Moteur du ventilateur Trousse dentr. surpresseur Ens. surcharge Relais Capaciteur * COMPREND RELAIS ET SURCHARGE. SI SOUS GARANTIE, REMPLACEZ AVEC LE MÊME SURPRESSEUR QUE CELUI UTILISÉ ORIGINALEMENT. NOTE : Toute correspondance au sujet des refroidisseurs deau courante ou toute commande de pièce de rechange DOIT inclure le numéro de modèle et le numéro de série du refroidisseur ainsi que le nom et le numéro de pièce à remplacer.
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 PARA PIEZAS, CONTACTE A SU DISTRIBUIDOR LOCAL O LLAME AL 1.800.323.0620 POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE 1.800.323.0620
ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.8484 97033C (Rev. E - 6/01) PAGE 4