Renaissance® 36” and 48” Wide Slide-in Gas Rangetops
ELECTRIC CIRCUIT REQUIREMENTS
WARNING •
•
PLANNING GUIDE
Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
Circuit Required
Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire)
0.25 Amp @ 120 Vac, 60 Hz
This appliance must be installed in accordance with the accompanying installation instructions.
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type
Manifold Pressure
Minimum Gas Supply Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 psi
IMPORTANT: Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the rangetop is less than 2 1/2” (Figure 2). When installing a backguard, use only Dacor model number AEB3609 (EG366) or AEB4809 (EG486).
A
Combustible rear wall PRODUCT DIMENSIONS - ISO VIEW
2 1/2” (6.4 cm) min. to combustible rear wall
A - Width EG366
35 7/8” (91.1 cm)
EG486
47 7/8” (121.6 cm)
28” (71.1 cm) 27” (68.6 cm) 26” (66.0 cm)
1 1/2” (3.8 cm) cooking surface height (grate level) above countertop
4” (10.2 cm)
Power cord 32” long
Trim: 7/16” (1.1 cm) thick
CABINET/COUNTERTOP SIDE VIEW WITHOUT BACKGUARD
Combustible rear wall
7 3/4” (19.7 cm)
Backguard mandatory if gap from back of rangetop to combustible wall is less than 2 1/2”
5/8” (1.6 cm)
3/4” gas inlet, connects to regulator from bottom or rear of unit, end is recessed 2” (5.1 cm) from chassis bottom PRODUCT DIMENSIONS - SIDE VIEW
All specifications subject to change without notice.
CABINET/COUNTERTOP SIDE VIEW WITH BACKGUARD
www.dacor.com
Phone: (800) 793-0093
EG366, EG486 Revised 10/20/14 Page 2/4
Document # PG04-001
Renaissance 36” and 48” Wide Slide-in Gas Rangetops
PLANNING GUIDE
Cabinet tolerances: +1/16” (+1.6 mm), -0 unless otherwise noted. 10” (25.4 cm) to combustible side wall min. both sides
1 1/2” (3.8 cm) typical countertop thickness
1/2” (1.3 cm) overhang, both sides B
Mounting platform 1” (2.5 cm) min. thickness
7 3/4” (19.7 cm) Recommended gas and electrical service location, consult local code
36” (91.4 cm) typical
CABINET/COUNTERTOP DIMENSIONS - FRONT VIEW 13” (33.0 cm) max.3
C
Model No.
Hood
B
C
EG366
36” (91.4 cm)
36” (91.4 cm)* 42” (106.7 cm)**
EG486
48” (121.9 cm)
48” (121.9 cm)* 54” (137.2 cm)**
* Minimum ** Recommended See note 2
18” (45.7 cm) min.1, 3
30” (76.2 cm) min.1 Top of finished counter
Cutout for utility access
Grate level
Grate level
CABINET/COUNTERTOP DIMENSIONS ISO VIEW 1 Vertical to combustible surface from rangetop grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 See Cabinet/Countertop Dimensions - Top View 3 This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from the edge of the rangetop.
All specifications subject to change without notice.
www.dacor.com
continued on following pages...
Phone: (800) 793-0093
EG366, EG486 Revised 10/20/14 Page 3/4
Document # PG04-001
Renaissance 36” and 48” Wide Slide-in Gas Rangetops
PLANNING GUIDE
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
Gas and electrical connections at right rear section of chassis
Gas connection and power cord may be routed through bottom or back of chassis Increase countertop and overhang additional 2 1/2” (6.4 cm) min. for combustible rear wall above countertop
Non-combustible rear wall, rear of mounting platform
10” (25.4 cm) min. to combustible wall above countertop, both sides
3/8” (1.3 cm) countertop overhang 1/2” (1.3 cm) countertop overhang
CL
1/2” (1.3 cm) countertop overhang Countertop
11 7/16” (29.1 cm)
Hole 1/2” dia. (1.3 cm), 2 places, through platform for hold down bolts
Countertop
24 5/8” (62.5 cm)
Gas/electrical utility cut-out in right rear corner of mounting platform 8” W X 6” D (20.3 cm X 15.2 cm), if gas and electrical are routed through bottom
1” (2.5 cm) thick mounting platform min.
D
CL
2” (5.1 cm) 1” (2.5 cm)
D
CL
CL
Cabinet face below countertop overhang
B CABINET/COUNTERTOP CUTOUT DIMENSIONS WITHOUT DOWNDRAFT VENT - TOP VIEW
Model No.
B - Cutout Width
D - Hole Offset
EG366
36” (91.4 cm)
16 5/8” (42.2 cm)
EG486
48” (121.9 cm)
20 13/16” (52.9 cm)
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
EG366, EG486 Revised 10/20/14 Page 4/4
Document # PG04-001
PLANNING GUIDE
Renaissance 36” and 48” Wide Slide-in Gas Rangetops Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
Non combustible rear wall recommended
3/8” (1.0 cm) min. countertop overhang
2 5/8” (6.7 cm)
10” (2.5 cm) min. to combustible wall above countertop, both sides
E Open to below to allow for downdraft vent, gas and electrical connections 1/2” (1.3 cm) countertop overhang
11 7/16” (29.1 cm)
Countertop
CL
Countertop
24 5/8” 15” (62.5 cm) (38.1 cm)
1/2” (1.3 cm) countertop overhang
1” (2.5 cm) thick mounting platform min.
Hole 1/2” dia. (1.3 cm), 2 places, through platform for hold down bolts
2” (5.1 cm) 1” (2.5 cm) D
CL
D
CL
Cabinet face below countertop overhang
CL
B CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH DOWNDRAFT VENT - TOP VIEW
3/8” min. (1.0 cm) flat countertop overhang required behind cutout Countertop
Model No.
Approved Downdraft Vent Models
EG366
ERV36, ERV3615, PRV36
EG486
ERV48, PRV48
Stiffener IMPORTANT: Use only the downdraft vents specified.
EG366 or EG486 rangetop 3/8” min. (1.0 cm) space behind downdraft vent chassis to clear stiffener
Control panel Cabinet face
Dacor approved downdraft vent
Minimum countertop height: 30 1/4" (76.8 cm)
Model No.
B - Cutout Width
D - Hole Offset
E - Downdraft Vent Cutout
EG366
36” (91.4 cm)
16 5/8” (42.2 cm)
33 1/2” (85.1 cm)
EG486
48” (121.9 cm)
20 13/16” (52.9 cm)
43 1/2” (110.5 cm)
IMPORTANT: See downdraft vent installation instructions for duct system layout/planning
CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH DOWNDRAFT VENT - SIDE VIEW All specifications subject to change without notice.