Preview only show first 10 pages with watermark. For full document please download

Eg366, Eg486 Planning Guide Warning

   EMBED


Share

Transcript

EG366, EG486 Revised 10/20/14 Page 1/4 Document # PG04-001 Renaissance® 36” and 48” Wide Slide-in Gas Rangetops ELECTRIC CIRCUIT REQUIREMENTS WARNING • • PLANNING GUIDE Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Circuit Required Total Connected Load 120 Vac 60Hz, 15 Amp. (3 wire) 0.25 Amp @ 120 Vac, 60 Hz This appliance must be installed in accordance with the accompanying installation instructions. Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5” Water Column 6” Water Column Propane (LP) 10” Water Column 11” Water Column * Maximum gas supply pressure for all models is 1/2 psi IMPORTANT: Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the rangetop is less than 2 1/2” (Figure 2). When installing a backguard, use only Dacor model number AEB3609 (EG366) or AEB4809 (EG486). A Combustible rear wall PRODUCT DIMENSIONS - ISO VIEW 2 1/2” (6.4 cm) min. to combustible rear wall A - Width EG366 35 7/8” (91.1 cm) EG486 47 7/8” (121.6 cm) 28” (71.1 cm) 27” (68.6 cm) 26” (66.0 cm) 1 1/2” (3.8 cm) cooking surface height (grate level) above countertop 4” (10.2 cm) Power cord 32” long Trim: 7/16” (1.1 cm) thick CABINET/COUNTERTOP SIDE VIEW WITHOUT BACKGUARD Combustible rear wall 7 3/4” (19.7 cm) Backguard mandatory if gap from back of rangetop to combustible wall is less than 2 1/2” 5/8” (1.6 cm) 3/4” gas inlet, connects to regulator from bottom or rear of unit, end is recessed 2” (5.1 cm) from chassis bottom PRODUCT DIMENSIONS - SIDE VIEW All specifications subject to change without notice. CABINET/COUNTERTOP SIDE VIEW WITH BACKGUARD www.dacor.com Phone: (800) 793-0093 EG366, EG486 Revised 10/20/14 Page 2/4 Document # PG04-001 Renaissance 36” and 48” Wide Slide-in Gas Rangetops PLANNING GUIDE Cabinet tolerances: +1/16” (+1.6 mm), -0 unless otherwise noted. 10” (25.4 cm) to combustible side wall min. both sides 1 1/2” (3.8 cm) typical countertop thickness 1/2” (1.3 cm) overhang, both sides B Mounting platform 1” (2.5 cm) min. thickness 7 3/4” (19.7 cm) Recommended gas and electrical service location, consult local code 36” (91.4 cm) typical CABINET/COUNTERTOP DIMENSIONS - FRONT VIEW 13” (33.0 cm) max.3 C Model No. Hood B C EG366 36” (91.4 cm) 36” (91.4 cm)* 42” (106.7 cm)** EG486 48” (121.9 cm) 48” (121.9 cm)* 54” (137.2 cm)** * Minimum ** Recommended See note 2 18” (45.7 cm) min.1, 3 30” (76.2 cm) min.1 Top of finished counter Cutout for utility access Grate level Grate level CABINET/COUNTERTOP DIMENSIONS ISO VIEW 1 Vertical to combustible surface from rangetop grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 See Cabinet/Countertop Dimensions - Top View 3 This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from the edge of the rangetop. All specifications subject to change without notice. www.dacor.com continued on following pages... Phone: (800) 793-0093 EG366, EG486 Revised 10/20/14 Page 3/4 Document # PG04-001 Renaissance 36” and 48” Wide Slide-in Gas Rangetops PLANNING GUIDE Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated Gas and electrical connections at right rear section of chassis Gas connection and power cord may be routed through bottom or back of chassis Increase countertop and overhang additional 2 1/2” (6.4 cm) min. for combustible rear wall above countertop Non-combustible rear wall, rear of mounting platform 10” (25.4 cm) min. to combustible wall above countertop, both sides 3/8” (1.3 cm) countertop overhang 1/2” (1.3 cm) countertop overhang CL 1/2” (1.3 cm) countertop overhang Countertop 11 7/16” (29.1 cm) Hole 1/2” dia. (1.3 cm), 2 places, through platform for hold down bolts Countertop 24 5/8” (62.5 cm) Gas/electrical utility cut-out in right rear corner of mounting platform 8” W X 6” D (20.3 cm X 15.2 cm), if gas and electrical are routed through bottom 1” (2.5 cm) thick mounting platform min. D CL 2” (5.1 cm) 1” (2.5 cm) D CL CL Cabinet face below countertop overhang B CABINET/COUNTERTOP CUTOUT DIMENSIONS WITHOUT DOWNDRAFT VENT - TOP VIEW Model No. B - Cutout Width D - Hole Offset EG366 36” (91.4 cm) 16 5/8” (42.2 cm) EG486 48” (121.9 cm) 20 13/16” (52.9 cm) All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093 EG366, EG486 Revised 10/20/14 Page 4/4 Document # PG04-001 PLANNING GUIDE Renaissance 36” and 48” Wide Slide-in Gas Rangetops Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated Non combustible rear wall recommended 3/8” (1.0 cm) min. countertop overhang 2 5/8” (6.7 cm) 10” (2.5 cm) min. to combustible wall above countertop, both sides E Open to below to allow for downdraft vent, gas and electrical connections 1/2” (1.3 cm) countertop overhang 11 7/16” (29.1 cm) Countertop CL Countertop 24 5/8” 15” (62.5 cm) (38.1 cm) 1/2” (1.3 cm) countertop overhang 1” (2.5 cm) thick mounting platform min. Hole 1/2” dia. (1.3 cm), 2 places, through platform for hold down bolts 2” (5.1 cm) 1” (2.5 cm) D CL D CL Cabinet face below countertop overhang CL B CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH DOWNDRAFT VENT - TOP VIEW 3/8” min. (1.0 cm) flat countertop overhang required behind cutout Countertop Model No. Approved Downdraft Vent Models EG366 ERV36, ERV3615, PRV36 EG486 ERV48, PRV48 Stiffener IMPORTANT: Use only the downdraft vents specified. EG366 or EG486 rangetop 3/8” min. (1.0 cm) space behind downdraft vent chassis to clear stiffener Control panel Cabinet face Dacor approved downdraft vent Minimum countertop height: 30 1/4" (76.8 cm) Model No. B - Cutout Width D - Hole Offset E - Downdraft Vent Cutout EG366 36” (91.4 cm) 16 5/8” (42.2 cm) 33 1/2” (85.1 cm) EG486 48” (121.9 cm) 20 13/16” (52.9 cm) 43 1/2” (110.5 cm) IMPORTANT: See downdraft vent installation instructions for duct system layout/planning CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH DOWNDRAFT VENT - SIDE VIEW All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093