Preview only show first 10 pages with watermark. For full document please download

Eh3512/eh3515 Series Environmental Enclosure Installation

   EMBED


Share

Transcript

® EH3512/EH3515 Series Environmental Enclosure Installation/Operation Manual C478M-H (6/97) Pelco • 300 W. Pontiac Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-209) 292-1981 FAX (800) 289-9150 or (1-209) 292-3827 • DataFAX (800) 289-9108 or (1-209) 292-0435 International Customers call (1-209) 292-1981 or FAX (1-209) 348-1120 CONTENTS Section Page 1.0 GENERAL .................................................................................................. 1 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 1 2.0 DESCRIPTION .......................................................................................... 2 2.1 MODELS ............................................................................................ 2 2.2 OPTIONS ........................................................................................... 2 3.0 INSTALLATION .......................................................................................... 3 3.1 RECOMMENDED CABLE SIZE ........................................................ 3 3.2 CAMERA/LENS INSTALLATION ....................................................... 5 3.3 HEATER AND BLOWER KIT INSTALLATION ................................... 6 3.3.1 Heater Kit (ONLY) Installation (HK3512-1/HK3512-2/HK3512-3) .......................................... 6 3.3.2 Heater/Blower Kit Installation (HK3512-1/BK3512-1, HK3512-2/ BK3512-2, or HK3512-3/BK3512-3) ...................................... 7 3.3.3 Blower Kit (ONLY) Installation (BK3512-1, BK3512-2, BK3512-3) ........................................ 7 4.0 MAINTENANCE ........................................................................................10 5.0 EXPLODED ASSEMBLY DIAGRAM ......................................................... 11 6.0 SPECIFICATIONS .................................................................................... 13 7.0 WARRANTY AND RETURN INFORMATION ........................................... 16 LIST OF ILLUSTRATIONS Figure 1 2 3 4 5 6 Page Heater and/or Blower Kit Installation (EH3512/EH3515 Only) ........... 8 Wiring Diagram for Heater Kit Only or Blower/Heater Combination .. 8 Wiring Diagram for Heater/Defroster (EH3512/EH3515) ................... 9 Wiring Diagram for Blower Kit Only (EH3512/EH3515) ..................... 9 EH3512/EH3515 Exploded Assembly Diagram ................................ 11 EH3512/EH3515 Dimension Drawing ............................................... 14 LIST OF TABLES Table A B C ii18 Page Enclosure Accessory Wiring Distances ............................................. 3 24 VAC Wiring Distances ................................................................... 4 Parts List (Figure 5) .......................................................................... 12 Pelco Manual C478M-H (6/97) REVISION HISTORY Pelco Manual C478M-H (6/97) Manual # Date Comments C478M 12/93 Original version. C478M 2/94 Rev. A. Manual revised for new blower kits (BK3512-1, BK3512-2, BK3512-3) and lock kit (LK3512). C478M 9/94 C478M addendum added to manual dated 2/94 for Section 4.1, Camera/Lens Installation. C478M-B 11/94 Rev. B. Revised to current format. Incorporated addendum which changed Section 4.1 installation instructions. New Figure 2 and Figure 6 drawings with corresponding changes in part list and revised Figures 3 and 4. Incorporates ECO numbers 94-128, 94-244 and 94-447 for camera sled, lid, latch and 24V fan capacitor changes. C478M-C 1/95 Rev. C. Revised Section 3.2 to include EH3512 Series Defroster Kits as per ECO #94-581 (for defroster kit installation information, refer to manual C1421M). Revised Exploded Assembly list of materials to include new UL gland size (ECO # 94-477) and new lid spring material (ECO # 94-478). C478M-D 6/95 Rev. D. Revised HK3512-1 and HK3512-2 descriptions to include new temperature ratings per ECO #95-140. Removed Sections 4.2.1 thru 4.2.3 (Heater and Blower Kits) and Section 4.3 (Sun Shroud) and created separate manuals for same (C1436M–BK3512/HK3512 series; C1437M–SS3508/SS3512) as accessories can be used with EH3508 and EH3512 enclosures. Figure 1 revised for 230 VAC heater wiring. C478M-E 10/95 Rev. E. Revised manual to include items previously deleted in the Rev. D version (i.e. Heater and Blower Kits) which are now updated to include a change in the adhesive used on the heater pads per ECO #95-358. Sections 4.2 through 4.2.3 address these items. Figures 1, 3 and 4 are new. Manual references updated accordingly. Separate manuals for the Heater and Blower Kits are still maintained and have also been updated (C1436M-A). C478M-F 8/96 Updated per ECO# 96-162, which modifies materials and revises exploded assembly drawing for heater and blower kits. C478M-G 11/96 Rev. G. Changed height dimension, weight, part numbers, and camera sled installation instructions per ECO #96-075. C478M-H 6/97 Rev H. Revised to include new models (EH3515, EH3515-1, EH3515-2, EH3515-3). 19 iii (This page intentionally left blank.) iv 20 Pelco Manual C478M-H (6/97) 1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry. 5. The installation method and materials should be capable of supporting four (4) times the weight of the enclosure, pan/tilt, camera and lens combination. The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USERSERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. Pelco Manual C478M-H (6/97) 1 2.0 DESCRIPTION The EH3512/EH3515 Series are indoor/outdoor light-duty camera enclosures designed for use with various cameras on the market and will accommodate fixed focal length lenses or motorized zoom lenses, with or without auto-iris operation. The lid of the enclosure is hinged in the front providing easy access during installation and when camera/lens adjustments are necessary. The camera sled itself (see Figure 5, Item 7) can serve as an elevation block. It can be removed, inverted and flipped, then reinstalled. All wiring and cabling is brought into the enclosure through adjustable glands at the bottom rear of the enclosure. The rear link-lock latch can be used with a padlock of suitable size for applications requiring additional security. Options for this series include heater, blower, defroster and sun shroud. 2.1 MODELS EH3512 Enclosure, indoor/outdoor, 12.75" (32.38 cm) lower body length. EH3512-1 Same as EH3512 except unit is supplied with 120 VAC blower and heater. EH3512-2 Same as EH3512 except unit is supplied with 24 VAC blower and heater. EH3512-3 Same as EH3512 except unit is supplied with 230 VAC blower and heater. EH3515 Enclosure, indoor/outdoor, 15.75" (40.00 cm) lower body length. EH3515-1 Same as EH3515 except unit is supplied with 120 VAC blower and heater. EH3515-2 Same as EH3515 except unit is supplied with 24 VAC blower and heater. EH3515-3 Same as EH3515 except unit is supplied with 230 VAC blower and heater. 2.2 OPTIONS 2 BK3512-1 Blower kit, continuous duty 120 VAC, 3.8 watts, 10 cfm @ 60 Hz BK3512-2 Blower kit, continuous duty 24 VAC, 1.92 watts, 19 cfm @ 50/ 60 Hz BK3512-3 Blower kit, continuous duty 230 VAC, 4.8 watts, 8 cfm @ 50 Hz HK3512-1 Heater kit, thermostatically controlled, 120 VAC, 40 watts. Activates ON at 50°F (10°C); OFF at 80°F (26.67°C) HK3512-2 Same as HK3512-1 except 24 VAC HK3512-3 Same as HK3512-1 except 230 VAC WD35-1 Window defroster kit, continuous duty, 3 watts, 120 VAC WD35-2 Same as WD35-1 except 24 VAC WD35-3 Same as WD35-1 except 230 VAC SS3512 Sun shroud for EH3512 Series SS3515 Sun Shroud for EH3515 Series Pelco Manual C478M-H (6/97) 3.0 INSTALLATION The following hardware is supplied to mount the enclosure: Quantity 2 2 2 Item 1/4-20 x .500 hex soc head screws (part # ZH1/420X.500CS) 1/4 flat washer (part # ZH260X562X65C) 1/4 split lock washer (part # ZH1/4LWSSL) The following hardware is supplied to mount the camera: Quantity 2 Item 1/4-20 x .375 pan head phillips (part # ZH1/420X.375SPP) 3.1 RECOMMENDED CABLE SIZE CAUTION: When using a single power source for both the camera and accessories, the camera power consumption must be taken into consideration when determining the wire gauge. However, Table A does not include camera power because of the many variations available. Before you begin, determine the wire run length needed for your application based on the information in Tables A and B. Table A lists the minimum recommended cable sizes for enclosures with heaters and/or blowers. Table B can be used for 24 VAC applications only (accessories and camera). Table A. Enclosure Accessory Wiring Distances Model Number EH3512-1, EH3515-1 (Heater & Blower) EH3512-2, EH3515-2 (Heater & Blower) EH3512-3, EH3515-3 (Heater & Blower) BK3512-1 (Blower only) BK3512-2 (Blower only) BK3512-3 (Blower only) HK3512-1 (Heater only) HK3512-2 (Heater only) HK3512-3 (Heater only) Pelco Manual C478M-H (6/97) Input Power Voltage Consumption Cable Size Cable Distance 120 VAC 43.8 watts 20 Awg 1,619 ft (493.4 m) at 60 Hz 18 Awg 2,576 ft (785.1 m) 16 Awg 4,089 ft (1,246.3 m) 14 Awg 6,523 ft (1,988.2 m) 24 VAC 41.92 watts 20 Awg 67 ft (20.4 m) at 60 HZ 18 Awg 107 ft (32.6 m) 16 Awg 170 ft (51.8 m) 14 Awg 272 ft (82.9 m) 230 VAC 49 watts 20 Awg 5,318 ft (1,620.9 m) at 50 HZ 18 Awg 8,460 ft (2,578.6 m) 16 Awg 13,427 ft (4,092.6 m) 14 Awg 21,420 ft (6,528.9 m) 120 VAC 3.8 watts 20 Awg 18,667 ft (5,689.7 m) 18 Awg 29,698 ft (9,052.0 m) 16 Awg 47,132 ft (14,366.0 m) 14 Awg 75,187 ft (22,917.2 m) 24 VAC 1.92 watts 20 Awg 1,477 ft (450.1 m) at 60 Hz 18 Awg 2,351 ft (716.5 m) 16 Awg 3,731 ft (1,137.2 m) 14 Awg 5,952 ft (1,814.1 m) 230 VAC 9 watts 20 Awg 28,954 ft (8,825.2 m) at 50 Hz 18 Awg 46,064 ft (14,040.4 m) 16 Awg 73,106 ft (22,282.9 m) 14 Awg 116,622 ft (35,546.8 m) 120 VAC 40 watts 20 Awg 1,773 ft (540.4 m) at 60 Hz 18 Awg 2,821 ft (859.8 m) 16 Awg 4,477 ft (1,364.6 m) 14 Awg 7,142 ft (2,176.9 m) 24 VAC 40 watts 20 Awg 70 ft (21.3 m) at 60 Hz 18 Awg 112 ft (34.1 m) 16 Awg 179 ft (54.5 m) 14 Awg 285 ft (86.8 m) 230 VAC 40 watts 20 Awg 6,514 ft (1,985.5 m) at 50 Hz 18 Awg 10,364 ft (3,158.9 m) 16 Awg 16,449 ft (5,013.7 m) 14 Awg 26,240 ft (7,998.0 m) 3 Table B. 24 VAC Wiring Distances The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10-percent voltage drop. (10-percent is generally the maximum allowable voltage drop for AC-powered devices.) Wire Gauge 20 Total vA consumed NOTE: Distances are calculated in feet; values in parentheses are meters. 4 18 16 14 12 10 10 283 (86) 451 716 (137) (218) 1142 1811 2880 (348) (551) (877) 20 141 (42) 225 358 (68) (109) 571 905 1440 (174) (275) (438) 30 94 (28) 150 (45) 238 (72) 380 603 960 (115) (183) (292) 40 70 (21) 112 (34) 179 (54) 285 (86) 452 720 (137) (219) 50 56 (17) 90 (27) 143 (43) 228 (69) 362 576 (110) (175) 60 47 (14) 75 (22) 119 (36) 190 (57) 301 (91) 480 (146) 70 40 (12) 64 (19) 102 (31) 163 (49) 258 (78) 411 (125) 80 35 (10) 56 (17) 89 (27) 142 (43) 226 (68) 360 (109) 90 31 (9) 50 (15) 79 (24) 126 (38) 201 (61) 320 (97) 100 28 (8) 45 (13) 71 (21) 114 (34) 181 (55) 288 (87) 110 25 (7) 41 (12) 65 (19) 103 (31) 164 (49) 261 (79) 120 23 (7) 37 (11) 59 (17) 95 (28) 150 (45) 240 (73) 130 21 (6) 34 (10) 55 (16) 87 (26) 139 (42) 221 (67) 140 20 (6) 32 (9) 51 (15) 81 (24) 129 (39) 205 (62) 150 18 (5) 30 (9) 47 (14) 76 (23) 120 (36) 192 (58) 160 17 (5) 28 (8) 44 (13) 71 (21) 113 (34) 180 (54) 170 16 (4) 26 (7) 42 (12) 67 (20) 106 (32) 169 (51) 180 15 (4) 25 (7) 39 (11) 63 (19) 100 (30) 160 (48) 190 14 (4) 23 (7) 37 (11) 60 (18) 95 (28) 151 (46) 200 14 (4) 22 (6) 35 (10) 57 (17) 90 (27) 144 (43) Maximum distance from transformer to load EXAMPLE: An enclosure that requires 80 vA and is installed 35 feet (10 m) from the transformer would require a minimum wire gauge of 20 Awg. Pelco Manual C478M-H (6/97) 3.2 CAMERA/LENS INSTALLATION To install the camera/lens, perform the following steps: 1. Unlatch lid and open. 2. Refer to Figure 5 for the location of the camera sled (item 7). Remove the camera sled from the rail: a. Loosen the screws. b. Slide the sled so that the screws are in the large part of the mounting holes. c. Remove the sled. d. Remove the parts tied to the sled. 3. Remove the wiring glands and nuts from the parts bag and install them in the bottom of the enclosure. 4. Mount the camera to the sled with the 1/4-20 Phillips-head screws that are provided in the parts bag. You can mount the camera to either side of the sled. Note that the edges of the sled are bent and that one lip is wide and the other is narrow. Normally you should mount the camera so that the wide lip of the sled fits over the mounting screws. If you are installing a camera with a low optical center line or a camera with a large diameter lens, mount the camera so that the narrow lip of the sled fits over the mounting screws. This elevates the sled. 5. There are two threaded mounting holes on the bottom of the enclosure. Mount the enclosure to a pan/tilt assembly or fixed mount with the 1/4-20 screws and washers that are supplied with the enclosure. 6. Install the sled and camera in the enclosure: 7. a. If the camera’s lens is adjustable, extend the lens to its maximum length. b. Place the sled on the rail over the attaching screws. c. Slide the sled so that the screws fit into the narrow slots of the mounting holes. d. Tighten the screws just enough to hold the sled to the rail, but not too tight to keep the sled from moving. e. Slide the camera sled forward until the lens almost touches the window. f. Tighten the screws to secure the camera sled to the rail. Pull the video and power cables through the glands and attach to the camera. Adjust the glands for a tight fit around the cables. Where applicable, connect the enclosure power wires to pins 1 and 2 (AC IN) at TB1 on the PC board. (Refer to Figure 2.) This power may also be used to power the camera if voltages are the same. The power may be “jumpered” from pins 1 and 2 (AC IN) or pins 4 and 5 (AC OUT) to the camera power input. (Refer to Figure 2.) Attach a BNC connector to the coax and connect to the camera. Pelco Manual C478M-H (6/97) 8. Adjust camera focus and iris, if necessary. Connect auto iris, if applicable. 9. Close the lid and latch. 5 3.3 HEATER AND BLOWER KIT INSTALLATION NOTE: If the camera and lens is already installed they will probably have to be removed in order to install the heater and blower kits. Refer to Section 3.2 for removal and installation instructions. Refer to Section 3.1, Recommended Cable Size, to determine the cable size needed for heater/blower installation. The following items are supplied in the heater and blower kits (refer to the appropriately numbered items in Figure 1). Qty Item 1 1 1 1 Heater pad: 4 2 2 3 2 4 Screw, 6-32 x 1.25" pan head, Phillips (BK3512-2 Only) Screw, 6-32 x 1.50 pan head, Phillips (BK3512-1 and -3 only) 4 Description Part Number Blower Kit Heater Kit EHWD10087 HTR40W230V2X2 EHHK10087 NA NA NA X X X Nylon washer ZH131X361X62N NA X Screw, 6-32 x 3/8" self-tapping ZH6-SFX.375SPP NA X ZH6-32X.32X1.25SPP X NA ZH6-32X1.50SPS X NA 120V/40W 230V/40W 24V/40W 2 5 #6 Internal star washer 1 6 6 6 Fan: ZH6LWSIS X NA MM750010003 MM750010003 ED210005* X X X NA NA NA 1 7 Circuit board and thermostat assembly PCB9100301ASSY NA X 1 8 Circuit board, 24 VDC fan rectifier (BK3512-2 only) PCB9000277ASSY X NA 1 9 Resistor, 3K ohm, 10 watt (BK3512-3 only) RES003.K10.0 X NA 120 VAC, 10 CFM @ 60 Hz 230 VAC, 8 CFM @ 50 Hz 24 VDC (AC rectified), 19 CFM * Utilizes a 1 amp, 400PRV bridge rectifier, part # DIOMDA104 3.3.1 Heater Kit (ONLY) Installation (HK3512-1/HK3512-2/HK3512-3) To install the heater kit perform the following steps: 6 1. Unlatch and open lid. 2. Using the two (2) 6-32 x 3/8" self-tapping screws (Item 3) and four (4) nylon washers provided (Item 2), attach the PC board assembly to the slots running along the bottom of the enclosure with the back edge of board even with the joint where the rear end cap joins to enclosure body. Refer to Figure 1. 3. To install the heater element in an EH3512 or EH3515, remove adhesive backing from the heating element and position near the press nut. Position so that heater element wires run down the “T” slot side of the enclosure. 4. Wire per the applicable wiring diagrams in Figure 2. Pelco Manual C478M-H (6/97) 3.3.2 Heater/Blower Kit Installation (HK3512-1/BK3512-1, HK3512-2/ BK3512-2, or HK3512-3/BK3512-3) To install the heater kit perform the following steps: 1. Unlatch and open lid. 2. Assemble the fan to the rear casting using the two (2) 6-32 x 1.25 for -2 version; (2) 6-32 x 1.50 for -1 and -3 versions), pan head Phillips screws (Item 4) and the two (2) #6 internal star washers (Item 5) provided. Refer to Figure 1. 3. Using the two (2) 6-32 x 3/8" self-tapping screws (Item 3) and four (4) nylon washers (Item 2) provided, attach the PC board assembly to the slots running along the bottom of the enclosure with the back edge of the PC board approximately 1/8" from the blower. Refer to Figure 1. 4. Follow instruction 3 of the previous section to install the heating element. 5. Wire per the wiring diagrams in Figure 2. 3.3.3 Blower Kit (ONLY) Installation (BK3512-1, BK3512-2, BK3512-3) To install the blower kit perform the following steps: Pelco Manual C478M-H (6/97) 1. Unlatch and open lid. 2. Assemble the fan to the rear casting using the two (2) 6-32 x 1.25 for -2 version; (2) 6-32 x 1.50 for -1 and -3 versions), pan head Phillips screws (Item 4) and the two (2) #6 internal star washers (Item 5) provided. Refer to Figure 1. 3. Wire per the wiring diagrams in Figure 4. 7 5 4 8 3 5 7 1 2 6 9 Figure 1. Heater and/or Blower Kit Installation (EH3512/EH3515 Only) Figure 2. Wiring Diagram for Heater Kit Only or Blower/Heater Combination 8 Pelco Manual C478M-H (6/97) Figure 3. Wiring Diagram for Heater/Defroster (EH3512/EH3515) Figure 4. Wiring Diagram for Blower Kit Only (EH3512/EH3515) Pelco Manual C478M-H (6/97) 9 4.0 MAINTENANCE Regularly scheduled maintenance will help prolong the operational life and appearance of the equipment. Clean the window regularly with a mild nonabrasive detergent in water and with a soft cloth to help maintain picture clarity. 10 Pelco Manual C478M-H (6/97) 5.0 EXPLODED ASSEMBLY DIAGRAM Refer to Figure 5 for exploded an assembly diagram of the EH3512/EH3515 enclosure. o. EXPAEH3512 Figure 5. EH3512/EH3515 Exploded Assembly Diagram Pelco Manual C478M-H (6/97) 11 Table C. Parts List (Figure 5) Item Quantity 1 2 3 4 1 2 2 1 Description Part Number 9 10 11 12 13 1 2 1 2 1 Pin, lid attachment Clip, type “E”, SS Gland, UL, PG-13.5 Body assembly w/thread strip (EH3512) (EH3515) Seal, bulb gasket x inch (EH3512) (EH3515) Latch link lock, no. 3, SS Camera sled w/keyhole slots Lid w/latch (EH3512) (EH3515) Hinge bracket, lid Squeeze bracket, window Window/gasket assembly UL, nut, PG-13.5, black Spring, torsion, type 316, SS A B C 2 6 2 Rivet, pop Washer, internal tooth #6, SS Screw, 6-32 x 3/8" pan hd, phillips, SS ZHRVT1/8X3/8CE ZH6LWSIS ZH6-32X.375SPP D E F G H 4 2 4 4 4 Screw, 6-32 x 3/8" pan hd, phillips, type A, SS Screw, 4-40 x 3/8" pan hd, phillips, SS Washer, nylon, flat Nut, hex 4-40, SS Washer lock, internal tooth #4, SS ZH6-SFX.375SPP ZH4-40X.375SPP ZH131X361X62N ZH4-40NUTSH ZH4LWSIS 5 36 42 1 1 1 *6 7 8 EH350010105 ZH.125ECLIP EH470010007B 37004000ASSY 35154000ASSY EH350010011 EH550010010 EH35004236COMP EH35004235COMP 35154003COMP EH35004141COMP EH35004142COMP EH35001000ASSY EH470010008B EH350010107 * EH3512 Series enclosures manufactured since November, 1994 have a manufacturing date code stamp of 4K (4 for 1994 and K for November) and utilize the above referenced latch. Units manufactured prior to November, 1994, having a date code of 4J (October of 1994) or less use the 1/4 turn wing latch. Replacement parts needed for this assembly are listed below. 1 1 1 1 2** 2** 2** Fastener, 1/4 turn, wing HD Washer, flat, neoprene Retainer, 1/4 turn fastener Fan/latch bracket assembly Washer, internal tooth #6, SS Washer, nylon, flat Screw, 6-32 x 1/4" pan hd, self tapping, phillips, SS ED210000 ZHX752-2 ED210002 EH35004148ASSY ZH6LWSIS ZH131X361X62N ZH6-SFX.250SPP **Hardware needed to attach the “Bracket, assembly, fan/latch”. 12 Pelco Manual C478M-H (6/97) 6.0 SPECIFICATIONS MECHANICAL Camera Mounting: Multiple holes on adjustable camera sled Camera and Lens Size: EH3512 EH3512-1/-2/-3 EH3515 EH3515-1/-2/-3 Viewing Window: Accommodates camera and lens combinations (including BNC connector) up to: 2.87" W x 3.00" H x 10.25" L (7.28 cm x 7.62 cm x 26.03 cm) 2.87" W x 3.00" H x 9.00" L (7.28 cm x 7.62 cm x 22.86 cm) 2.87" W x 3.00" H x 13.25" L (7.28 cm x 7.62 cm x 33.66 cm) 2.87" W x 3.00" H x 12.00" L (7.28 cm x 7.62 cm x 30.48 cm) 3/16" (4.76 mm) thick, optically clear, impact resistant Lexan™ MR5 coated (U.L. 94HB rated). Window Viewing Area: 2.25" H x 2.63" W (5.71 cm x 6.68 cm) Cable Entry: Two PG13.5 compression glands on bottom rear Cable Entry Holes: 0.875" (will accept 1/2" conduit fitting when compression gland is removed) Latch: Rear link lock latch GENERAL Construction: Extruded and die cast aluminum Dimensions: See Figure 6 Environment: -10° to 120° F (-23.33° to 48.89° C) Weight: EH3512 EH3512-1/-2/-3 EH3515 EH3515-1/-2/-3 Unit 3.45 lbs (1.56 kg) 3.95 lbs (1.79 kg) 4 lbs (1.81 kg) 4.4 lbs (1.99 kg) Shipping Weight 4.00 lbs (1.81 kg) 4.50 lbs (2.04 kg) 5 lbs (2.27 kg) 5 lbs (2.27 kg) (Design and product specifications subject to change without notice.) Pelco Manual C478M-H (6/97) 13 Figure 6. EH3512/EH3515 Dimension Drawing 14 Pelco Manual C478M-H (6/97) NOTES Pelco Manual C478M-H (6/97) 15 7.0 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one (1) year after the date of shipment. Exceptions to this warranty are as noted below: • • • • • Two (2) years on all standard motorized and fixed focal length lenses. Two (2) years on Legacy®, Intercept®, CM8500/CM9500/CM9750 Matrix, Spectra™ , DF5 Series and DF8 Fixed Dome products. Two (2) years on WW5700 series window wiper (excluding wiper blades). Two (2) years on cameras. Six (6) months on all pan and tilts, scanners or preset lenses used in continuous motion applications (e.g., preset scan, tour and auto scan modes). Pelco will warranty all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty. Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise. The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state. If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (209) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: 1. 2. 3. Model and serial number Date of shipment, P.O. number, Sales Order number, or Pelco invoice number Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned. Ship freight prepaid to: Pelco 300 West Pontiac Way Clovis, CA 93612-5699 Method of return shipment shall be the same or equal to the method by which the item was received by Pelco. RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (209) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair). Goods returned for repair or credit should be clearly identified with the assigned CA/RA number and freight should be prepaid. All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge. ®Pelco and the Pelco logo are registered trademarks of Pelco. ©Copyright 1997, Pelco. All rights reserved. 16 Ship freight prepaid to: Pelco 300 West Pontiac Way Clovis, CA 93612-5699 Pelco Manual C478M-H (6/97)