Preview only show first 10 pages with watermark. For full document please download

Eit 12 Hazard Alarm And Access Control Systems - Lucas

   EMBED


Share

Transcript

Table of Contents Table of Contents Building management systems Building management systems EIT 12 Hazard alarm and access control systems Lucas Nülle GmbH Page 1/12 1 2 2 3 www.lucas-nuelle.com Building management systems Training systems / trainers for electrical wiring/building management systems: Protective circuitry, protective measures, building mains feed, lighting and intercom systems Industrial wiring, intercoms, alarm systems, hazard alarms and access control KNX/EIB, LON Project work, technical practice, assembly practice systems, planning software Building management systems Building management systems Building management covers all aspects of advanced modern wiring installation. Nowadays, more and more things are being automated. In addition, such matters as energy saving, protection of the environment and safety of course have a key role to play as well. Building management systems of such a kind often consist of programmable bus systems which can be connected together as needed. The training course conveys basic knowledge and some small-scale applications can then be implemented. Lucas Nülle GmbH Page 2/12 www.lucas-nuelle.com Lighting management using DALI Lighting management nowadays means more than just flexibility, energy saving and comfort. DALI stands for “Digital Addressable Lighting Interface” and is a protocol for digital communication between electronic lighting controls and appliances (electronic ballast units, transformers etc.). The new comprehensive system, consisting of a controller, sensor, extender and buttons, is characterised by the option of programming with or without computers or an overarching bus system. Configuration of the buscontrolled lighting system can be handled entirely by means of the display integrated into the controller with the help of a push-button rotary switch. Light management covers all areas of public life, including the following: Living room and building lighting Special effects lighting Industrial and street lighting Emergency and escape route lighting EIT 12 Hazard alarm and access control systems EIT 12 Hazard alarm and access control systems With the new hazard alarm training system, training staff can teach how burglar and fire alarms are key components of a modern wiring installation. Training focuses on how individual sensors work and how alarms, sensors, arming systems and a central interface can be wired together. The system can be programmed as desired and can be used in highly varied ways for advanced training. The hazard alarm system consists of modules typically used in practice, all of which are authorised by the VdS, a subsidiary of the German Insurance Association. Basic knowledge of project planning for alarm systems Basic knowledge of project planning for burglar alarm systems Basic knowledge of project planning for fire alarm systems Basic knowledge of project planning for access control systems Physical operating principle for various types of sensor Installation of gas, water, smoke and break-in sensors Configuration of conventional alarm modules Installation of bus-connected sensors and alarms Programming of the system via PC or control unit Lucas Nülle GmbH Page 3/12 www.lucas-nuelle.com Equipment set comprising the following: Pos. Product name Bestell-Nr. 1 Bus-controlled hazard alarm systems with LAN and web interfaces Anz. CO3209-4Q 1 CO3209-4R 1 The KNX hazard alarm control unit handles management of up to 5 logical zones with up to 344 alarm modules, of which 8 are built-in. Another 128 alarm modules can be integrated via KNX. The network connection is used for parameter setting, control and display via the accompanying web server. The equipment can be used in systems with high security requirements conforming to VdS (subsidiary of the German Insurance Association) categories A, B and C, DIN VDE 0833 levels 1, 2 and 3 and EN 50 131/IEC 62 642 levels 1, 2 and 3. Technical data: Power supply range: 85…265 V AC Mains frequency: 50/60 Hz Output voltage: 13.2 V DC ±0.5 V Interfaces: RJ45, KNX Inputs and outputs: 2-mm safety sockets Dimensions: 297 x 456 x 80 mm Weight: 3.0 kg 2 LCD control unit for hazard alarm systems This control and display unit is designed for controlling and displaying data from hazard alarm systems. The display shows information on system status. Multi-function and special buttons can be configured to operate all the functions of the system. Secure functions are protected by PIN unique to each user. Key information is also indicated via LEDs. Technical data: Operating voltage: 13.2 V DC +0.5 V (via S-Bus 3) Operating indicators: Operating LED (green) indicates that the equipment is in operation Notification LED (yellow) indicates alarms triggered in the area Fault LED (yellow) indicates faults/alarms in the area Alarm LED (red) indicates alarms relating to the system or local area Controls: Multi-function buttons activate the functions shown on the display Numeric buttons For entering PIN Arming button Arming of system/area Disarming button Disarming of system/area Reset button Reset of alarms, faults and alarm sensors with saved alarms Menu button Invokes the controller’s menu Audio button Deactivates the audio signal Inputs and outputs: 2-mm safety sockets Dimensions: 297 x 228 x 80 mm Weight: 1.4 kg Lucas Nülle GmbH Page 4/12 www.lucas-nuelle.com 3 Conventional and bus-connected alarm sensors for motion detection, glass breakage and locking indication CO3209-4U 1 CO3209-4V 1 This board includes various burglar alarm sensors. These sensors can be connected to conventional inputs of an alarm control unit. Sensor group modules can also be used to make conventional sensors capable of use on a bus system, thus reducing the wiring effort required. Modules: 2 Double sensor group modules, for connection to bus 1 Bolt contact 1 Magnetic contact 1 Reed contact 1 Glass-break detector 1 Infra-red motion sensors, for connection to bus 4 Terminating resistors 1 Tampering simulation switch Technical data: Input voltage: 13.2 V DC ±0.5 V (bus) Inputs and outputs: 2-mm safety sockets Dimensions: 297 x 228 x 80 mm Weight: 2.5 kg 4 Various alarm sensors for fire This board includes various sensors for fire alarm systems These sensors can be connected to conventional inputs of an alarm control unit. Modules: 3 Fire detector sockets with relay contact 1 Temperature-limit detector 1 Heat differential detector 1 Optical smoke detector 3 Terminating resistors Technical data: Input voltage: 13.2 V DC ±0.5 V (bus) Inputs and outputs: 2-mm safety sockets Dimensions: 297 x 456 x 80 mm Weight: 2.0 kg Lucas Nülle GmbH Page 5/12 www.lucas-nuelle.com 5 Various alarm sensors for fire, intruders, water and gas CO3209-4W 1 CO3209-4T 1 This board includes additional sensors for hazard alarm systems These sensors can be connected to conventional inputs of an alarm control unit. Modules: 1 Manually operated fire alarm/building alarm 1 Intruder alarm 1 Water leak/moisture detector 1 Gas leak detector 4 Terminating resistors Technical data: Input voltage: 13.2 V DC ±0.5 V (bus) Inputs and outputs: 2-mm safety sockets Dimensions: 297 x 228 x 80 mm Weight: 2.5 kg 6 Access control plus visual and audio alarm systems This board includes alarm systems for both visual and audio indication as well as an arming and evaluation unit. Two programmable access keys are also included with the evaluation unit. Technical data: Operating voltage: 13.2 V DC ±0.5 V (via S-Bus 3) Inputs: Power supply, 12 V DC for supply of locking elements Locking element for connection of a locking element Door contact for connecting a magnetic reed contact Door bolt for connecting a door bolt detector switch Tamper for connecting a contact to detect the removal of the wall-mounted reader from the wall (WELT/A) Outputs: Transistor output 1 (max. 20 mA) for indicating "internal alarm" status Transistor output 2 (max. 20 mA) for indicating "access" Transistor output 3 (max. 15 mA) for indicating "external or internal arming" status Transistor output 4 (max. 15 mA) for indicating "ready for arming (external)" status Controls and display elements Function switch blocks 1…3 for configuration of functions and addressing LED 2 (green) For indicating communication between modules and arming unit Inputs and outputs: 2-mm safety sockets Dimensions: 297 x 228 x 80 mm Weight: 2.5 kg Lucas Nülle GmbH Page 6/12 www.lucas-nuelle.com Media: Pos. Product name Bestell-Nr. 7 Interactive Lab Assistant: Gefahrenmeldetechnik Anz. SO2801-3R 1 Das Lernprogramm läuft innerhalb eines vorbereiteten Browsers zur Steuerung, Verwaltung und Anzeige des Lernprogramms und der virtuellen Instrumente. Eine umfangreiche Auswertung der Lernergebnisse der einzelnen Schüler muss möglich sein. Ausgewertet werden dabei die im Kurs enthaltenen Testfragen. Inhalte: Analyse der Projektaufgabe Planung der Projektbearbeitung Grundlagen der Gefahrenmeldetechnik Normen und Richtlinien VdS Klassen Z-Verdrahtung Begriffe und Symbole Inbetriebnahme der Zentrale Aufbau einer Gefahrenmeldezentrale Inbetriebnahme der Zentrale Inbetriebnahme der Alarmiereinrichtungen, akustisch und optisch Inbetriebnahme der Bedieneinrichtung Aufbau einer Zutrittskontrolle Kennelernen verschiedener Zutrittskontrollsysteme Scharf- und Unscharf Schaltbedingungen Inbetriebnahme der Zutrittskontrolle Inbetriebname von Riegelschaltkontakten Programmierung und Rechtevergabe von Transpondern Aufbau einer Einbruchmeldeanlage Kennenlernen verschiedener Melder Kennenlernen der Ensatzmöglichkeiten verschiedener Alarmsensoren Inbetriebnahme von Reedkontakten und Glasbruchmeldern Inbetriebnahme von Überfall- und Bewegungsmeldern Aufbau einer Brandmeldeanlage Kennenlernen verschiedener Melder in abhängigkeit der zu erfassenden physikalischen Größen Inbetriebnahme automatischer Brandmelder Inbetriebnahme von Handbrandmeldern Integration weiterer Gefahrenmelder Inbetriebnahme von Wassermeldern Inbetriebnahme von Gasmeldern Programmierung eines Hausalarms Lucas Nülle GmbH Page 7/12 www.lucas-nuelle.com Measuring instruments: Pos. Product name Bestell-Nr. 8 Voltage, phase + continuity tester with field direction indicator, max. 400V LM8554 Anz. 1 Robust, safe and easy-to-use test instrument for voltages up to 690V. Tests voltage, phase, polarity and continuity as well as indicating the direction of a rotating (three-phase) electrical field. Type PROFISAFE 690B IP 65 model with 2 LEDs and 7 level bar graph Power supplied by a rechargeable lithium battery which can be recharged by mains terminal Voltage insulation strength > 6 kV VDE-GS tested Measurement category of instrument CAT IV Nominal voltage range 12 ... 690 V Display ranges 12, 24, 50, 120, 230, 400, 690 V Input resistance 167 kΏ Frequency range 0 ... 500 Hz Current 3.4 mA On period 30 s Continuity testing 0 ... 1000 kΏ Lucas Nülle GmbH Page 8/12 www.lucas-nuelle.com Accessories: Pos. Product name Bestell-Nr. 9 Set of 72 safety measurement leads, 2mm for Instrain SO5148-1P Anz. 1 Set of safety measurement leads with stackable 2-mm laminated plugs and highly flexible, double-insulated leads, consisting of the following: 10 safety connector leads, 2mm,100cm, black 10 safety connector leads, 2mm, 100cm,red 22 safety connector leads, 2mm, 100cm, yellow 10 safety connector leads, 2mm, 60cm, black 10 safety connector leads, 2mm, 60cm, red 10 safety connector leads, 2mm, 60cm, yellow Wire cross section 0.5 mm ² Rating: 600V, CAT II, 10A Lucas Nülle GmbH Page 9/12 www.lucas-nuelle.com 10 Mobile aluminium experiment stand, 3 levels, power strip with 6 sockets, 1250x700x1995mm ST7200-3A 1 High-quality, mobile experiments stand from the SybaPro range for demonstrations and experiments. Features aluminium profile legs compatible with all add-ons and extensions for the SybaPro system. The mobile experiment stand is supplied in kit form and needs to be assembled by customers themselves. Table top: 30-mm table top made of highly compressed, multi-layer fine chipboard conforming to DIN EN 438-1 Colour grey, RAL 7035, with 0.8-mm slightly textured laminate coating (Resopal) on both sides, conforming to DIN 16926 Resistant to many chemicals and reagents including dilute acids and alkalis Resistant to heat, e.g. molten solder or heating at specific points such as by soldering tips or cigarette ends Table top with solid impact-resistant protective edging made of 3mm thick RAL 7047 coloured plastic Coating and adhesive are PVC free Power strip with 6 outlet sockets mounted underneath the table top, lead and earthed plug Frame: 2 extruded aluminium profiles with multiple grooves 1800 x 120 x 40 mm (WxHxD) 8 equally sized grooves in extruded aluminium profiles (3 on each side and 1 each on the front and back) Grooves accommodate standard industrial mountings 4 H-shaped aluminium profiles, 1150 mm, for 3-layer organisation of DIN A4 panels Space for extension of power supply duct Base made of rectangular tubing with 4 swiveling double casters, 2 of which have brakes Table frame made of tough combination of rectangular tubing around the full perimeter Acid-resistant epoxy-resin coating, 80 µm thick (approx.), colour RAL 7047 Dimensions: Height of table top 760 mm 1250 x 1995 x 700 mm (WxHxD) Lucas Nülle GmbH Page 10/12 www.lucas-nuelle.com 11 PC holder for SybaPro experiment trolleys, height/width adjustable ST7200-5A 1 ST8003-8G 1 Shelf for desktop PC made of 1.5mm sheet steel punched with holes, suitable for all furniture in the SybaPro aluminium profile range Adjustable assembly height Adjustable width (160 - 255mm) Can be mounted to left or right Includes all equipment necessary for assembly (4 bolts and 4 tenon blocks) Acid-resistant epoxy-resin powder coating, 80µm thick approx., colour RAL7047 12 Trolley for measurement leads (max. length 150cm), for up to 320 (2x 160) measurement leads Accommodates about 120 safety measuring leads (2mm), suitable for mounting on walls or aluminium profiles Width 200 mm, 24 guide grooves for leads Adjustable height for mounting on aluminium profiles Can be mounted on the left or right Can be mounted on walls Includes 2 screws and tenon blocks Acid-resistant epoxy-resin powder coating, thickness 80 µm approx., colour RAL 7047 Lucas Nülle GmbH Page 11/12 www.lucas-nuelle.com 13 Monitor holder for flat screen monitor of weight up to 10kg/22lb, VESA 75/100 ST8010-4L 1 ST8010-9Y 1 Pivoting monitor holder for attachment to aluminium profiles of furniture in the SybaPro range. Allows a monitor to be placed in the optimum position so that work and experiments are less tiring. Pivoting arm with two-part joint Quick-lock for adjustment to any height on extruded aluminium profile VESA fastening 7.5 x 7.5cm Includes VESA 75 (7.5x7.5) - VESA 100 (10x10) adapter 2 Cable clips Adequate carrying capacity 10kg/22lb TFT monitor can be turned parallel to the table edge Separation can be adjusted to anywhere between 105 and 480mm Additionally included: Cable management set for installing cables along the profiles of the aluminium lab system furniture in the SybaPro range The set consists of the following: 3 Cross cable binders for front and rear grooves of aluminium profile 3 Cross cable binders for side grooves of aluminium profile 12 Cable binders 4 Aluminium cover profiles for covering and enabling wires to be run along the grooves of an aluminium profile Includes assembly instructions 14 Protection cover for three-level experiment trolleys Dust cover for three-level experiment trolleys For protecting equipment from dust and damp For keeping equipment out of sight (the cover must not be transparent, so is therefore opaque) Colour: matt dark grey with printed LN logo in orange) Material: nylon fabric with polyurethane coating High resistant to tearing, impregnated to be washable and waterproof Lucas Nülle GmbH Page 12/12 www.lucas-nuelle.com