Preview only show first 10 pages with watermark. For full document please download

Electra 2011_pxd Dc

   EMBED


Share

Transcript

Floor/Ceiling PXD DC INVERTER Product benefits Horizontal or vertical unit mounting Perfect comfort, unequalled unobtrusiveness, great accuracy in maintaining the desired temperature and controlling air quality. !R410A «green» fluid. !Optimal efficiency : Class A energy label (depending on models). !Heating mode operation down to outdoor temperatures of -15 °C. !Optimal temperature regulation. !Electronic regulation and programming. !Dual automatic treat air sweeping. !!Fluid pre-charged at the factory for up to 20 m pipe lengths (depending on models). !Low wall or ceiling mounting. !Possibility of air conditioning two separate rooms with a single unit. !!Compatible with DUO, TRIO, QUATTRO and CINCO DCI Multisplits. !! Possibility of air conditioning 2 separate rooms with a single unit OU DC 9-12-18 DCI Indoor units PXD 9-12-18-21-24 DCI RC7 Remote cont control RCW2 Remote control (accessory) OU VBD 022-024 DCI • Part number 7ACEL1212 Accessories Condensate lift pump Air distribution unit Rear panel tube cover Mounting bracket 16 • Part number • Part number • Part number • Part number PXD 9 DCI 7ACFH0221 7ACVF0122 7ACTL0073 7ACTL0016 PXD 12 DCI 7ACFH0221 7ACVF0122 7ACTL0073 7ACTL0016 PXD 18 DCI 7ACFH0221 7ACVF0123 7ACTL0074 7ACTL0016 PXD 21 DCI 7ACFH0221 7ACVF0123 7ACTL0074 - ELECTRA 2011 AIR CONDITIONING & HEATING CATALOGUE 4 DC Inverter models: from 2 500 to 6 300 W PXD DC INVERTER SERIES PXD 9 DCI Indoor Units Outdoor Units PXD 9 DCI PXD 12 DCI PXD 18 DCI PXD 21 DCI AC DC 9 INV R410 AC DC 12 INV R410 ELAU-VBD018-H11 ELAU-VBD022-H11 PXD 24 DCI ELAU-VBD024-H11 2.5 (1.4-3.6) 0.62 4.03/A 3.5 (1.5-4.4) 0.98 3.57/A 5 (1.5-5.8) 5.7 (1.5-6.4) 1.51 1.78 3.31/A 3.2/A v -10°/46° Dry bulb k 6.8 (1.5-7.6) 2.25 3.02/B 3.2 (1.5-4.5) 1.9 0.93 3.41/B 4.2 (1.5-5.0) 2.5 1.31 3.21/B 5.6 (1.3-6.5) 6.3 (1.6-7.5) 2.3 1.59 1.75 3.52/B 3.6/A v -15°/24° Dry bulb k 7.6 (1.6-8.6) 2 105 3.61/A dB(A) dB(A) m3/h l/h mm kg 29/37/42 41/49/54 300/350/400 1 820x190x630 21 ESP012133 30/41/45 51/53/56 300/400/450 1.5 820x190x630 22 ESP012134 40/48/51 56/60/65 600/750/870 2 1200x190x630 30 ESP012135 43/47/51 55/59/63 650/780/920 2 1200x190x630 31 ESP012163 46/51/58 58/63/69 800/950/1020 2.5 1200x190x630 32 ESP012164 dB(A) dB(A) m3/h 51 61 1780 Rotary DC Inverter 795x290x610 38 ESP061483 52 62 1780 Rotary DC Inverter 795x290x610 38.5 ESP061720 53 63 2160 Rotary DC Inverter 795x290x610 38 ESP061686 56 66 2860 Twin Rotary DC Inverter 846x302x690 45 ESP061715 56 69 3600 Twin Rotary DC Inverter 950x412x835 64.5 ESP061714 Linking specifications between indoor and outdoor units Power supply 1~230V-50Hz Power supply side Indoor Power cable section mm2 3x1.5 Fuse rating am A 16 Electrical connections mm2 4x1.5 Indoor 3x1.5 16 4x1.5 Indoor 3x2.5 20 4x2.5 Indoor 3x2.5 20 4x2.5 Outdoor 3x2.5 25 4x2.5 Pipe line Suction pipe diameter Liquid pipe diameter Max lenght Max height 3/8” 1/4” 20 10 1/2” 1/4” 20 10 1/2” 1/4” 20 10 5/8” 3/8” 30 15 Capacity Input power EER/Energy Label Outdoor temperature operating limits kW kW Capacity Capacity at -15°C Input power COP/Energy Label Outdoor temperature operating limits kW kW kW Indoor unit Sound pressure level to 1 m (LS/MS/HS) Sound power level (LS/MS/HS) Airflow (LS/MS/HS)(CO/HP) Dehumidification Dimensions (WxDxH) Weight • Part number Outdoor unit Sound pressure level to 1 m Sound power level Airflow Compressor type Dimensions (WxDxH) Weight • Part number PXD 12 DCI °C °C mm kg inches inches m m 3/8” 1/4” 20 10 PXD 18 DCI PXD 21 DCI PXD 24 DCI 17