Preview only show first 10 pages with watermark. For full document please download

Electric Documentation

   EMBED


Share

Transcript

1 2 3 4 5 6 7 8 Q1 L1 L2 L3 T1 L1 T2 L2 T3 L3 L1 PE L2 6 4 2 5 3 1 E1 Date 05/13/13 User LY9ELCAD Format A4 7:4 353 354 355 K21 E2 E3 Electrolux Laundry Systems SE-341 80 LJUNGBY SWEDEN Electric Documentation Page 1 of 9 Principle schematic 43232006837 1 2 3 4 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) L1 L2 5 6 7 8 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) POWER BUS 301 L1 302 L2 305 304 F15 F16 20AT 20AT 1 V1 2 U 1 2 1 X311 X302 HO2 HO1 CPU + YELLOW LO3 LO2 2 UNBALANCE LO1 - + Rx Tx X312 1 2 3 4 1 2 3 4 X301 5 + CPU X301 1 2 3 1 OC9 - + X304 U1 EWD 2300 2 - OC4 + 1 + HO3 DC bus - Interlock Safety device Tacho GREEN X302 OC8 INTERLOCK CPU SUPPLY DC bus + + 2 15V 1 X311 2 6 7 8 6 7 8 X308 MOTOR 1 2 3 4 1 2 3 4 5 Com 3 / 4:6 GREEN YELLOW Date 05/13/13 User LY9ELCAD Format A4 OK CPU not running Current limiting SE-341 80 LJUNGBY SWEDEN GY 1 4 2 5 3 6 7 8 9 1 4 2 5 3 6 7 8 9 Com 4 / 4:6 Heatsink to hot Motor to hot No Interlock Output shortcout Harware faliure DC bus to high voltage DC bus to low voltage No tacho signal Electrolux Laundry Systems GY WH Blu Blu Blk Blk Com 2 / 4:6 WH Com 1 / 4:6 YE GN RD U V W M 3~ Electric Documentation M1 Page 2 of 9 Principle schematic 43232006837 1 2 3 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) 4 5 6 7 8 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) POWER BUS DATA BUS L1 301 X7 3 2 230 - 0V 1 302 9 400 - 0V 1 L2 1 (DATA) 2 (CLK) 3 (GND) 4 (+9V) T2 X7 304 3 7 305 4 1 2 3 4 1 2 P-BUS/BL Con2 4 1 2 3 4 P-BUS/BL 3 1 2 3 4 D-BUS/GY Con4 1 2 3 4 +9V Gnd Clk Data +9V Gnd Data 4 D-BUS/GY Con5 1 2 3 4 Clk Line 2 Neutral 1 L Interlock 4 Con3 N Interlock 3 Line 2 Neutral L Interlock N Interlock 1 3 + 9VDC + ˜ + ˜ 2 PSU/YE 1 Con1 1 Line 2 Neutral F1 Electrolux Laundry Systems SE-341 80 LJUNGBY SWEDEN - F2 3,15 AT Date 05/13/13 User LY9ELCAD Format A4 + Primary Switching Unit + - Electric Documentation A30 PSU Page 3 of 9 Principle schematic 43232006837 1 2 3 4 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) 5 6 7 8 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) POWER BUS DATA BUS 1 (DATA) 2 (CLK) 3 (GND) 4 (+9V) 1 (DATA) 2 (CLK) 3 (GND) 4 (+9V) / 1 2 3 4 D-bus 5V R RE DE A Count inp +5V +5V +5V Motor Tx Motor Rx Mot Config 1 2 3 4 +5V S2 S3 S4 NTC OUT EN DAT 0 DAT 1 DAT 2 DAT 3 DAT 4 DAT 5 DAT 6 DAT 7 CS1 CS2 DRES BL OFF VPWM DC +5V +5V M7 M6 M5 M4 M3 M2 M1 CPU 5V A100 Mot Config J2 D B Z Y J1 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 M-COM ENC DISPLAY 1 2 3 4 5 6 7 8 1 2 3 4 J11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 J9 1 2 3 4 5 6 7 8 J12 J13 Rx+ RxTxTx+ 120 ohm 1 2 3 4 1 2 3 4 5 6 Tacho J3 1 2 3 4 J4 1 2 D-BUS / Tacho/BL 1 2 3 4 5 6 7 Com 1 / 2:6 Tacho 2 CPU / 6:3 Tacho 1 CPU / 6:3 NC / 6:3 D-BUS CPU 4 / 6:3 D-BUS CPU 3 / 6:3 D-BUS CPU 2 / 6:3 D-BUS CPU 1 / 6:3 Com 2 / 2:6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 ENC 1 1 2 3 20 5 MEMBRANE SWITCH Date 05/13/13 User LY9ELCAD Format A4 Com 4 / 2:6 A2 DISPLAY 6 1 2 3 4 Com 3 / 2:6 S5 4 A9 Electrolux Laundry Systems SE-341 80 LJUNGBY SWEDEN ENCODER Electric Documentation Page 4 of 9 Principle schematic 43232006837 1 2 3 4 5 6 7 POWER BUS 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) 1 (DATA) 2 (CLK) 3 (GND) 4 (+9V) 1 (DATA) 2 (CLK) 3 (GND) 4 (+9V) DATA BUS 1 2 J7 1 2 J8 +5V Coin 1 Coin 2 Coin Block Switch RIN Led ROUT +9V SD TOUT V- TIN C1+ VCC C1- +5V USB type A GND J6 +9V Price prog CPU Inp 2 +5V Inp 1 +5V A100 JFLASH1 +5V INT Tx INT Rx J10 8 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) J5 1 2 3 4 1 2 3 4 5 6 EMERG/OG 1 2 S2 Date 05/13/13 User LY9ELCAD Format A4 Electrolux Laundry Systems SE-341 80 LJUNGBY SWEDEN Electric Documentation Page 5 of 9 Principle schematic 43232006837 1 2 3 4 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) 5 6 7 8 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) POWER BUS DATA BUS 1 (DATA) 2 (CLK) 3 (GND) 4 (+9V) 1 2 3 4 1 D-BUS/GY 4 1 +5V +5V 1 2 3 3 4 J10 1 2 3 4 + + + Door closed Power On + Closed U3 Line Log. out Door locked - Line Locked Neutral Neutral Locked Count inp Line Un Lock Lock Un Lock 9V + Lock 4 +5V +5V 10 J9 2 P-BUS/BL Data Clk GND +9V Log inp +5V +5V +7VDC AD inp I/O type AD inp 1 2 3 4 A110 Switch 3 P-BUS/BL +5V J4 2 + 1 (DATA) 2 (CLK) 3 (GND) 4 (+9V) Led - + U4 J20 - U6 J1 J3 1 2 3 4 5 1 2 3 4 J2 J5 1 2 D-BUS / TACHO/BL LEVEL/RD 1 2 3 4 5 B2 P 12 1 2 3 B4 1 2 J7 1 2 J8 J11 1 2 1 2 TEMP/BL DO/RD 1 2 3 4 5 6 7 11 1 2 J6 1 2 3 4 5 6 DOOR IN/BL 1 2 1 2 3 4 5 6 1 2 3 4 5 6 Tacho 2 CPU / 4:8 Tacho 1 CPU / 4:8 NC / 4:8 D-BUS CPU 4 / 4:8 D-BUS CPU 3 / 4:8 D-BUS CPU 2 / 4:8 D-BUS CPU 1 / 4:8 1 2 3 Analog pressure sensor B1 1 Θ 2 A41 S4.a Y80 Door lock solenoid Un Lock Lock Date 05/13/13 User LY9ELCAD Format A4 Electrolux Laundry Systems SE-341 80 LJUNGBY SWEDEN Electric Documentation + S4.b Door lock locked S3 Door closed + - Page 6 of 9 Principle schematic 43232006837 2 3 4 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) 5 6 7 8 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) POWER BUS 1 (DATA) 2 (CLK) 3 (GND) 4 (+9V) 1 (DATA) 2 (CLK) 3 (GND) 4 (+9V) DATA BUS 1 2 3 4 1 2 3 4 P-Bus Con 112 1 2 1 2 3 4 D-bus 3 4 Con 119 A101 D-bus 1 2 3 4 1 2 3 4 Con 118 Con 117 1 2 3 4 5 P-LOAD +5V 1 RL7 RL9 RL6 RL5 RL4 RL3 RL2 RL1 2 3 4 1 2 2 1 2 HEAT 3 4 1 1 2 HOT 2 1 1 2 1 2 1 COLD 2 1 2 1 2 5 6 1 2 7 8 1 2 1 2 Con 116 1 Con 114 2 Con 115 1 Con 101 2 Con 102 1 DRAIN P-BUS 1 2 Con 103 1 Con 104 4 Con 105 3 Con 106 2 Con 107 1 Con 108 D Con 109 Funktion Con 110 1 Con 111 I/O type Con 113 +9V RL10 RS 232 Led Log inp +5V IC105 INT Tx INT Rx + Log inp - +5V + 1 2 3 4 COLD 2 1 2 3 4 1 (Interlock N) 2 (Interlock L) 3 (Neutral) 4 (Line) Y20 Y1 Y10 Y14 Y13 Y12 Y11 K21 A1 Date 05/13/13 User LY9ELCAD Format A4 Electrolux Laundry Systems SE-341 80 LJUNGBY SWEDEN A2 Electric Documentation Page 7 of 9 Principle schematic 43232006837 4 5 6 W5.... S2 7 8 F1, F2 A30 PSU Y10 3 Y20 2 Y11 Y12 Y13 Y14 1 K21 Q1 Y1 A101 S3 S4a S4b Y80 U1 A41 E1 E2 E3 B1 B3 M1 T2 Date 05/13/13 User LY9ELCAD Format A4 Electrolux Laundry Systems SE-341 80 LJUNGBY SWEDEN Blue BU Red RD B4 Green GN Yellow YE A110 A100 Purpel VT Silver GY Black BK Brown BN Pink PK Orange OG Electric Documentation B2 Page 8 of 9 Component place list 43232006837 1 2 3 4 5 6 7 8 ID. Beskrivning Description Beschreibung Description A2 A9 A30 A41 A100 A101 A110 B1 B2 B4 E1 E2 E3 F1 F2 F15 F16 K21 M1 Q1 S2 S3 S4.a S4.b S5 T2 U1 V1 Y1 Y10 Y11 Y12 Y13 Y14 Y20 Y80 Display Panelskylt Nätdel Lucklåsenhet CPU, Kontrollpanelen Unit I/O kort typ 1 I/O kort typ 10 Temperaturgivare Nivåvakt Nivågivare tvättprogram Värmeelement Värmeelement Värmeelement Säkring manöver 3,15AT Säkring manöver 3,15AT Säkring motorstyrning 20,0AT Säkring motorstyrning 20,0AT Värmekontaktor Motor Huvudbrytare Stopp Gränslägesbrytare stängd lucka Gränslägesbrytare låst lucka Gränslägesbrytare låst lucka Programväljare Transformator motorstyrning/manöverspänning Motorstyrning Varistor Ventil avlopp Ventil inlopp kallt trumma Ventil inlopp kallt fack 1 Ventil inlopp kallt fack 2 Ventil inlopp kallt fack 3 Ventil inlopp kallt fack 4 Ventil inlopp varmt trumma Lucklåsspole Display Panel sign Power Supply Unit Door lock unit CPU, Control Panel Unit I/O card type 1 I/O card type 10 Temperature sensor Level switch Level transmitter wash program Heating element Heating element Heating element Fuse control system 3,15AT Fuse control system 3,15AT Fuse Motorconverter 20,0AT Fuse Motorconverter 20,0AT Heating contactor Motor Main switch Stop Limit switch door closed Limit switch door locked Limit switch door locked Program Selector Transformer motor controller/control voltage Motor controller Varistor Drain valve Inlet valve cold, drum Inlet valve cold, soap box 1 Inlet valve cold, soap box 2 Inlet valve cold, soap box 3 Inlet valve cold, soap box 4 Inlet valve hot, drum Coil door lock Display Panelschild Transformator Programmwerk Türverriegelung CPU, Bedienfeldeinheit I/O-Karte typ 1 I/O-Karte typ 10 Temperatursensor Niveauschalter Niveaugeber Waschprogramm Heizelement Heizelement Heizelement Sicherung Steuersystem 3,15AT Sicherung Steuersystem 3,15AT Sicherung Motorsteuerung 20,0AT Sicherung Motorsteuerung 20,0AT Heizkontaktgeber Motor Hauptschalter Stopp Grenzpositionsschalter geschlossene Tür Grenzpositionsschalter verriegelte Tür Grenzpositionsschalter verriegelte Tür Programwähler Transformator Motorsteuerung/Steuerspannung Motorsteuerung Varistor Ventil Abfluss Ventil Einlauf Kalt Trommel Ventil Einlauf Kalt Fach 1 Ventil Einlauf Kalt Fach 2 Ventil Einlauf Kalt Fach 3 Ventil Einlauf Kalt Fach 4 Ventil Einlauf Warm Trommel Spule Türverriegelung Écran Symbole panneau de commande Transformateur minuterie Unité verrouillage porte CPU, Unité de panneau de commande E/S Carte type 1 E/S Carte type 10 Capteur de température Interrupteur de niveau Interrupteur de niveau programme de lavage Elément chauffant Elément chauffant Elément chauffant Fusible commande 3,15AT Fusible commande 3,15AT Fusible Contrôleur du moteur 20,0AT Fusible Contrôleur du moteur 20,0AT Contacteur chauffage Moteur Interrupteur principal Arrêt Contact fin de course porte fermée Contact fin de course porte verrouillée Contact fin de course porte verrouillée Sélecteur de programme rotatif Transformateur commande moteur/tension de commande Contrôleur du moteur Varistance Vanne de vidange Vanne d'admission, froid, tambour Vanne d'admission, froid, boîte à produits 1 Vanne d'admission, froid, boîte à produits 2 Vanne d'admission, froid, boîte à produits 3 Vanne d'admission, froid, boîte à produits 4 Vanne d'admission, chaud, tambour Bobine verrouillage porte Date 05/13/13 User LY9ELCAD Format A4 Electrolux Laundry Systems SE-341 80 LJUNGBY SWEDEN Electric Documentation Page 9 of 9 Component list 43232006837