Preview only show first 10 pages with watermark. For full document please download

Electric Dryer Installation Instructions Table Of Contents

   EMBED


Share

Transcript

ELECTRIC DRYER INSTALLATION INSTRUCTIONS Table of Contents DRYER SAFETY.......................................................................... 2 INSTALLATION REQUIREMENTS.............................................. 3 Tools and Parts....................................................................... 3 LOCATION REQUIREMENTS..................................................... 4 ELECTRICAL REQUIREMENTS................................................. 6 INSTALL LEVELING LEGS.......................................................... 7 ELECTRICAL INSTALLATION.................................................... 8 Power Supply Cord Connection............................................ 9 Direct Wire Connection........................................................ 11 VENTING.................................................................................... 14 Venting Requirements.......................................................... 14 Plan Vent System.................................................................. 15 Venting Kits........................................................................... 15 Install Vent System............................................................... 16 CONNECT INLET HOSE........................................................... 17 CONNECT VENT....................................................................... 18 LEVEL DRYER........................................................................... 19 COMPLETE INSTALLATION CHECKLIST............................... 19 DOOR REVERSAL KIT (OPTIONAL)........................................ 20 STACKING WASHER AND DRYER (OPTIONAL).................... 20 TROUBLESHOOTING............................................................... 20 Para una version de estas instrucciones en español, visite www.Whirlpool.com INSTALLATION NOTES Date of purchase:__________________________________ Date of installation:________________________________ Installer:_________________________________________ Model number:____________________________________ Serial number:____________________________________ W10385103B W10385104B - SP 1 DRYER SAFETY IMPORTANT: When discarding or storing your old clothes dryer, remove the door. 2 INSTALLATION REQUIREMENTS TOOLS AND PARTS Gather the required tools and parts before starting installation. Tools needed: Parts needed: (Not supplied with dryer) ■■ Vent clamps ■■ Vent elbows and ductwork Additional parts may be required, depending in your installation. Check local codes. Check existing electrical supply and venting. Read “Electrical Requirements” and “Venting Requirements” before purchasing parts. Flat-blade screwdriver Wire stripper (direct wire installations) #2 Phillips screwdriver Tin snips (new vent installations) If using a power supply cord: Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain: ■■ A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends. ■■ A UL listed strain relief. Parts supplied: Parts package is located in dryer drum. Check that all parts are included. NOTE: Do not use leveling legs supplied if installing with a pedestal or a stack kit. 1/4" and 5/16" nut driver (recommended) Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench Leveling legs (4) Utility knife Tape measure Short inlet hose (steam models only) Level “Y” connector (steam models only) Long inlet hose (steam models only) Pliers Rubber washers (steam models only) Optional Equipment: (Not supplied with dryer) Caulking gun and compound (for installing new exhaust vent) Refer to your Use and Care Guide for information about accessories available for your dryer. 3 LOCATION REQUIREMENTS Check code requirements. Some codes limit, or do not permit, installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. DRYER DIMENSIONS Front view: 27" (686 mm) 35 3/8" (899 mm) 1"* (25 mm) * Approx. measurement Side view: You will need: ■■ A location allowing for proper exhaust installation. See “Venting Requirements.” ■■ A separate 30 amp circuit. ■■ If using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.” ■■ Floor must support dryer weight of 200 lbs. (90.7 kg). Also consider weight of companion appliance. ■■ Cold water faucets located within 4 ft. (1.2 m) of the water fill valves, and water pressure of 20 - 120 psi (138 - 827 kPa). You may use the water supply for your washer using the “Y” connector and short hose (if needed) which are provided. ■■ Level floor with maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly. ■■ For garage installation, place dryer at least 18" (460 mm) above floor. If using a pedestal, you will need 18" (460 mm) to bottom of dryer. ■■ The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. IMPORTANT: Do not operate, install, or store dryer where it will be exposed to water, weather, or at temperatures below 40° F (4° C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times. 48 3/4" (1238 mm) 35 3/8" (899 mm) 31/2" (89 mm) Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. 6 7/8" (174 mm) 1"* (25 mm) * Approx. measurement Back view: 61/4" (159 mm) Power supply cord or cable Installation Clearances For each arrangement, consider allowing more space for ease of installation and servicing; spacing for companion appliances and clearances for walls, doors, and floor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required. 29" (736 mm) Vent 1"* (25 mm) * Approx. measurement Water inlet† 14" (358 mm) 281/8" (715 mm) Vent: 31/2" (89 mm) Water Inlet: 31/4" (83 mm) 61/8" (156 mm) † Steam models only NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.” 4 Installation spacing for recessed area or closet installation Cabinet installation (dryer only): All dimensions show recommended and minimum spacing allowed. ■■ Additional spacing should be considered for ease of installation and servicing. 7" (178 mm) ■■ Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line. ■■ Additional spacing should be considered on all sides 18" (460 mm) of the dryer to reduce noise transfer. ■■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. ■■ Companion appliance spacing should also be considered. Recommended installation clearances: 5" (127 mm) Closet installation (dryer only): 3" (76 mm) 34" recommended (864 mm) 18" min. (457 mm) 1" (25 mm) 1" (25 mm) 48 in.2 (310 cm2) Custom under counter installation (dryer only): 3" (76 mm) 5" (127 mm) 1" (25 mm) 24 in.2 (155 cm2) 39" min. (990 mm) 1" (25 mm) 1" (25 mm) Closet Installation (stacked washer and dryer): 6" (152 mm) 1" (25 mm) Mobile home - Additional installation requirements: 3" (76 mm) 76" (1930 mm) 48 in.2 (310 cm2) This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH. Mobile home installations require: ■■ Metal exhaust system hardware, available for purchase from 5" (127 mm) 1" (25 mm) 3" (76 mm) 1" (25 mm) 24 in.2 (155 cm2) your dealer. For further information, see “Assistance or Service” section in your Use and Care Guide. ■■ Special provisions must be made in mobile homes to introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening. 5 ELECTRICAL REQUIREMENTS It is your responsibility: ■■ To contact a qualified electrical installer. ■■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition and all local codes and ordinances. The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations. A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269. ■■ To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. ■■ Do not use an extension cord. ■■ If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Electrical Connection To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. ■■ This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground conductor must be removed from the external ground connector (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground conductor is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor. The green ground wire of the 4-wire power cord must be secured to the dryer cabinet with the green ground screw. ■■ If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section. ■■ A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations after 1996, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors. If using a power supply cord: Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain: ■■ A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends. ■■ A UL listed strain relief. 6 If your outlet looks like this: Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft. (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground 4-wire receptacle conductor) may be either green or bare. The (14-30R) neutral conductor must be identified by a white cover. Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft. (1.22 m) long, must have three 10-gauge 3-wire receptacle copper wires and match a 3-wire receptacle of NEMA Type 10-30R. (10-30R) If connecting by direct wire: Power supply cable must match power supply (4-wire or 3-wire) and be: ■■ Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), covered with flexible metallic conduit. All current-carrying wires must be insulated. ■■ 10-gauge solid copper wire (do not use aluminum) at least 5 ft. (1.52 m) long. INSTALL LEVELING LEGS 1. Prepare dryer for leveling legs To avoid damaging floor, use a large flat piece of cardboard from dryer carton; place under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard. 2. Screw in leveling legs diamond marking Examine leveling legs, find diamond marking. Screw legs into leg holes by hand, use a wrench to finish turning legs until diamond marking is no longer visible. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent. 7 ELECTRIC INSTALLATION For power supply cord installations: For direct wire installations: Before you start: disconnect power. 1. Choose electrical connection type 2. Remove terminal block cover Power supply cord 4-wire receptacle (NEMA Type 14-30R). Go to Power Supply Cord Connection. Power supply cord 3-wire receptacle (NEMA Type 10-30R). Go to Power Supply Cord Connection. 4-wire direct connection: Go to Direct Wire Connection. 3-wire direct connection: Go to Direct Wire Connection. NOTE: If local codes do not permit connection of a cabinet-ground conductor to neutral wire, go to “Optional 3-wire connection”. This connection may be used with either a power supply cord or a direct wire connection. 8 Remove hold-down screw and terminal block cover. Power Supply Cord Connection Power supply cord strain relief: 4-Wire Power Supply Cord Connection 1. Attach power supply cord strain relief IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections. A B 4-wire receptacle (NEMA type 14-30R) 4-prong plug Spade terminals with upturned ends Ring terminals C D Remove the screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections (C) into the hole below the terminal block opening (B) so that one tab is pointing up (A) and the other is pointing down (D), and hold in place. Tighten strain relief screws just enough to hold the two clamp sections (C) together. 2. Attach power supply cord 1. Prepare to connect neutral ground wire and neutral wire to strain relief E B A Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point. Remove center, silver-colored terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A). 2. Connect neutral ground wire and neutral wire If your outlet looks like this: Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to 4-Wire Power Supply Cord Connection on this page. B E C Power supply cord 3-wire receptacle (NEMA Type 10-30R): Go to 3-Wire Power Supply Cord Connection on page 10. Connect neutral ground wire (E) and neutral wire (white or center) (C) of power supply cord under center terminal block screw (B). Tighten screw. 9 3. Connect ground wire 1. Remove center screw A B F Connect ground wire (F) (green or bare) of power supply cord under green external ground conductor screw (A). Tighten screw. 4. Connect remaining wires Remove center terminal block screw (B). 2. Connect neutral wire B C Connect remaining wires under outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements. Connect neutral wire (white or center) (C) of power supply cord under center terminal block screw (B). Tighten screw. 3. Connect remaining wires 3-Wire Power Supply Cord Connection Use where local codes permit connecting cabinet-ground conductor to neutral wire. 10 3-wire receptacle (NEMA type 10-30R) 3-prong plug Spade terminals with upturned ends Ring terminals Connect remaining wires under outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements. Direct Wire Connection 4-Wire Direct Wire Connection Direct wire strain relief IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit 3-wire connections. 1. Attach direct wire strain relief 1. Prepare your 4-wire cable for direct connection A 31 ⁄2" m) (89 m B 1" m) (25 m C 5 (127 " mm ) Unscrew the removable conduit connector (A) and any screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief (C) through the hole below the terminal block opening (B). Reaching inside the terminal block opening, screw the removable conduit connector (A) onto the strain relief threads and tighten securely. 2. Attach direct wire cable to strain relief Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed. Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 11/2" (38 mm) from remaining 3 wires. Strip insulation back 1" (25 mm). Shape ends of wires into hooks. 2. Prepare to connect neutral ground wire and neutral wire E B A Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable. Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A). If your wiring looks like this: 4-wire direct connection: Go to 4-Wire Direct Connection on this page. 3-wire direct connection: Go to 3-Wire Direct Connection on page 12. 11 3-Wire Direct Wire Connection 3. Connect neutral ground wire and neutral wire Use where local codes permit connecting cabinet-ground conductor to neutral wire. B E 1. Prepare your 3-wire cable for direct connection 1" C m) (25 m 3½" (89 m m) Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of terminal block (B). Squeeze hooked ends together and tighten screw. 4. Connect ground wire Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed. Strip 31/2" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape wire ends into hooks. 2. Remove center screw A B F Connect ground wire (green or bare) (F) of direct wire cable under green external ground conductor screw (A). Tighten screw. 5. Connect remaining wires Remove center terminal block screw (B). 3. Connect neutral wire B C Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements. 12 Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B), hook facing right. Squeeze hooked end together. Tighten screw. 4. Connect remaining wires 2. Connect neutral ground wire and neutral wire B E C Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements. Optional External Ground for 3-Wire Connection Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center, terminal block screw (B). Tighten screw. 3. Connect remaining wires (Power Supply Cord Shown) IMPORTANT: You must verify with a qualified electrician that this grounding method is acceptable before connecting. 1. Prepare to connect neutral ground wire and neutral wire E B A Place ends of remaining wires under outer terminal block screws. Tighten screws. 4. Connect external ground wire Install the correct strain relief for your electrical connection method, as shown on page 9 or 11. Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A). A G Connect a separate copper ground wire (G) under the green external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements. 13 VENTING Exhaust hoods: Venting Requirements insects from entering the home. ■■ Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow). ■■ Do not use an exhaust hood with a magnetic latch. ■■ An exhaust hood should cap the vent to keep rodents and Recommended Styles: Louvered Hood Box Hood Acceptable Style: WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting. Angled Hood Elbows: ■■ 45° elbows provide better airflow than 90° elbows. 4" (102 mm) Good Better 4" (102 mm) heavy metal exhaust vent ■■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used. ■■ Do not use plastic or metal foil vent. Rigid metal vent: ■■ Recommended for best drying performance and to avoid crushing and kinking. Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance. ■■ Do not install in enclosed walls, ceilings, or floors. ■■ The total length should not exceed 73/4 ft. (2.4 m). ■■ The length of flexible metal vent used must be included in the overall vent system design as shown in the Vent System Chart. NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review Vent System Chart and if necessary, modify existing vent system to achieve best drying performance. 14 Clamps: ■■ Use clamps to seal all joints. ■■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape. Alternate exhaust installations (for close clearance): Plan Vent System Choose your exhaust installation type Recommended exhaust installation: B C A D E F G B Over-the-top installation (also available with one offset elbow) H A. Dryer B Elbow C. Wall D. Exhaust hood E. Clamps F. Rigid metal or flexible metal vent G. Vent length necessary to connect elbows H. Exhaust outlet Optional exhaust installations: Periscope installation Special provisions for mobile homes: Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside. If you prefer, dryer may be converted to exhaust out right side, left side, or through bottom. You must contact your local dealer to have dryer converted. 15 Determine vent path: ■■ Select route that will provide straightest and most direct path outdoors. ■■ Plan installation to use fewest number of elbows and turns. ■■ When using elbows or making turns, allow as much room as possible. ■■ Bend vent gradually to avoid kinking. Install Vent System 1. Install exhaust hood 12" min. (305 mm) ■■ Use as few 90° turns as possible. Determine vent length and elbows needed for best drying performance: ■■ Use the following Vent System Chart to determine type of vent material and hood combinations acceptable to use. NOTE: Do not use vent runs longer than those specified in Vent system chart. Exhaust systems longer than those specified will: ■■ Shorten life of dryer. ■■ Reduce performance, resulting in longer drying times and increased energy usage. The Vent System Chart provides venting requirements that will help achieve best drying performance. 12" min. (305 mm) Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood. 2. Connect vent to exhaust hood NOTE: Side and bottom exhaust installation have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart. Vent System Chart Number of 90° elbows Type of vent Box/louvered hoods Angled hoods 0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m) 1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m) 2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m) 3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) 16 Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint. CONNECT INLET HOSE 3. Tighten couplings (Steam models only) For non-steam models, proceed to “Connect Vent”. The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses. NOTE: Replace inlet hoses after 5 years of use to reduce the risk of hose failure. Record hose installation or replacement dates on the hoses for future reference. Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found. 1. T urn cold water off, remove hose, and replace rubber washer Using pliers, tighten the couplings with additional two-thirds turn. NOTE: Do not overtighten. Damage to the coupling can result. 4. Attach long hose to “Y” connector and tighten couplings Turn cold water faucet off and remove washer inlet hose. Check and see if rubber washer is in the “Y” connector. Remove old rubber washer from inlet hose and replace with new rubber washer provided. 2. A ttach short hose and “Y” connector One end of the long hose has a wire mesh strainer inside the coupling. Attach this end to the “Y” connector. Attach washer cold inlet hose to other side of “Y” connector. Screw on coupling by hand until it is seated on connector. Using pliers, tighten the couplings an additional two-thirds turn. A B NOTE: Do not overtighten. Damage to the coupling can result. If space permits, attach the female end of the “Y” connector to the cold water faucet. See figure A. If “Y” connector cannot be attached directly to the cold water faucet, the short hose must be used. See figure B. Attach short hose to cold water faucet. Screw on coupling by hand until it is seated on faucet. Then attach “Y” connector to male end of the short hose. Screw on coupling by hand until it is seated on connector. 17 5. A ttach long hose to dryer fill valve and tighten coupling CONNECT VENT 1. Connect vent to exhaust outlet Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp. Remove protective cap from water inlet valve. Attach other end of long hose to fill valve at bottom of dryer back panel. Screw on coupling by hand until it is seated on fill valve connector. Using pliers, tighten the couplings an additional two-thirds turn. 2. Move dryer to final location NOTE: Do not overtighten. Damage to the coupling can result. 6. Turn on cold water faucet Move dryer to final location, taking care not to crush or kink vent. After dryer is in place, remove corner posts and cardboard from under dryer. Check that the water faucets are turned on. 7. Check for leaks Check for leaks around “Y” connector, faucet, and hoses. 18 LEVEL DRYER COMPLETE INSTALLATION CHECKLIST q Check that all parts are now installed. If there is an extra 1. Level dryer part, go back through steps to see what was skipped. q Check that you have all of your tools. q Dispose of/recycle all packaging materials. q Check dryer’s final location. Be sure vent is not crushed Place level here or kinked. q Check that dryer is level. See “Level Dryer”. q Remove film on console and any tape remaining on dryer. q Wipe dryer drum interior thoroughly with a damp cloth to remove any dust. Check levelness of dryer from side to side. Repeat from front to back. q Read “Dryer Use” in your Use and Care Guide. q For power supply cord installation, plug into a grounded NOTE: The dryer must be level for the moisture sensing system to operate correctly Steam Models Only: outlet. For direct wire installation, turn on Power. q Be sure the water faucets are on (steam models only). q Check for leaks around “Y” connector, faucet, and hoses. q If you live in a hard water area, use of a water softener is Not Level LEVEL Not Level recommended to control the buildup of scale through the water system in the dryer. Over time, the buildup of lime scale may clog different parts of the water system, which will reduce product performance. Excessive scale buildup may lead to the need for certain part replacement or repair. All Models: 2. Adjust leveling legs q Select a Time Dry heated cycle, and start dryer. Do not select Air Only Temperature setting. If dryer will not start, check the following: • Controls are set in a running or “On” position. • Start button has been pushed firmly. • Dryer is plugged into an outlet and/or electrical supply. • Household fuse is intact and tight, or circuit breaker has not tripped. • Dryer door is closed. This dryer automatically runs an installation diagnostic routine at the start of its first cycle. If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once dryer is level, make sure all four legs are snug against the floor and the dryer does not rock. NOTE: You may notice an odor when dryer is first heated. This odor is common when heating element is first used. The odor will go away. 19 DOOR REVERSAL (OPTIONAL) If you prefer to reverse the door swing on your dryer: A door reversal kit, Part Number W10406955 is available to order. For further information, see “Assistance or Service” section in your Use and Care Guide. STACKING WASHER AND DRYER (OPTIONAL) If you prefer to stack your washer and dryer: A stack kit, Part Number 8572546, is available to order. For further information, see “Assistance or Service” section in your “Use and Care Guide”. TROUBLESHOOTING See your “Use and Care Guide” or visit our website and reference Frequently Asked Questions to possibly avoid the cost of a service call. W10385103B W10385104B - SP © 2011 All rights reserved 06/11 Printed in U.S.A.