Transcript
Electrical temperature measurement
Electrical thermometer with tapered thermowell For shipbuilding industry Models TR293, TC293 WIKA data sheet TE 69.25
T YPE APPROVED
Applications ■■ Exhaust gas temperature measurement in diesel engines
and turbines
■■ For On-, Offshore plants
Special features ■■ Robust
■■ Medium temperature to 850 °C with thermocouple, to
600 °C with resistance thermometer
■■ Approval Lloyd's Register
Description
Electrical thermometer model Tx293
These model Tx293 electrical thermometers are used for the measurement of exhaust gas temperatures on diesel engines and turbines. The standard temperature range is 0 ... 850 °C for thermocouples, 0 ... 600 °C for resistance thermometers. The thermowells are designed for the loads which occur in medium and large power plants. These thermometers are suitable for ambient temperatures to 200 °C. The process connection is made via male connectors, with a standard insertion length of 202 mm.
WIKA data sheet TE 69.25 ∙ 05/2014
Page 1 of 4
Resistance thermometer for model TR293
Neck
■■ Class B
Sensor tolerance value per DIN EN 60751
Material Stainless steel 1.4571
The combination of a 2-wire connection with Class B is not permissible, because the lead resistance of the measuring insert overrides the higher sensor accuracy.
Neck length MH 50, 100 mm others on request
For detailed specifications for Pt100 sensors, see Technical Information IN 00.17 at www.wika.com.
Diameter 15 mm
Thermocouple for model TC293 Sensor type ■■ K (NiCr-Ni) Application range up to 850 °C ■■ J (Fe-CuNi) Application range up to 600 °C Listed thermocouples are available both as single or dual thermocouples. The thermocouple will be delivered with an insulated measuring point. Tolerance value For the tolerance value of thermocouples, a cold junction temperature of 0 °C has been taken as the basis. Type K Class
Temperature range
DIN EN 60584 part 2 2 -40 ... +333 °C 2 +333 ... +1200 °C
Tolerance value ± 2.5 °C ± 0.0075 ∙ | t | 1)
1) | t | is the value of the temperature in °C irrespective of the sign.
Type J Class
Temperature range
DIN EN 60584 part 2 2 -40 ... +333 °C 2 +333 ... +750 °C
Tolerance value
Process connection Mode of connection Threaded connection Material Stainless steel 1.4571 Thread G¾B others on request
Thermowell Design from solid-machined material, tapered Material Stainless steel 1.4571 Diameter 23 mm, tapered to 14 mm Insertion length 100, 150, 202, 250 mm other versions on request
± 2.5 °C ± 0.0075 ∙ | t | 1)
1) | t | is the value of the temperature in °C irrespective of the sign.
Tolerance value at selected temperatures in °C Temperature Tolerance value DIN EN 60584 part 2 (ITS 90) Type K Type J °C °C °C 0
200
400
600
800
Page 2 of 4
± 2.5
± 2.5
± 3.0
± 4.5
± 6.0
± 2.5
± 2.5
± 3.0
± 4.5
undefined
WIKA data sheet TE 69.25 ∙ 05/2014
Dimensions in mm
3376139.02
Model Tx293 with connection head BS
Legend: E Thread MH Neck length U1 Insertion length
Connection head
BS Model BS BSZ KNE BSK
BSZ Material
Aluminium Aluminium Aluminium Plastic
KNE Cable entry M20 x 1.5 M20 x 1.5 M20 x 1.5 M20 x 1.5
BSK Ingress protection IP 54 IP 65 IP 65 IP 54
Cap
Cap with 2 screws Hinged cover with cylinder head screw Screw cover Screw cover
Surface finish Epoxy coated Epoxy coated Epoxy coated not coated
1) Cable gland, metal
WIKA data sheet TE 69.25 ∙ 05/2014
Page 3 of 4
Electrical connection Model TR293 1 x Pt100, 3-wire
1 x Pt100, 4-wire
3160629.05
1 x Pt100, 2-wire
red
red red
red red
white
white
white white
Dual thermocouple
Single thermocouple The colour coding at the positive poles of the instrument decides the correlation of polarity and connection terminal.
3166822.03
Model TC293
Colour coding Sensor type
Standard
Positive
Negative
K J
DIN EN 60584 DIN EN 60584
green black
white white
Ordering information Model / Sensor connection method / Process conenction / Neck length MH / Insertion length U1 / Connection head
Page 4 of 4
WIKA data sheet TE 69.25 ∙ 05/2014
WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406
[email protected] www.wika.de
05/2014 GB
© 2003 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.