Preview only show first 10 pages with watermark. For full document please download

Elpro_tzva10_user_manual_eng

   EMBED


Share

Transcript

TZVA 05/10 5x1 AND 10x1 VIDEO & AUDIO SWITCHER − − − − − − − − − − − − − − − − • 300 MHz BANDWIDTH. − • INTEGRATED KEYBOARD. − • REMOTE SELECTION BY DRY CONTACTS. − − • REMOTE SELECTION BY RS 232. • AUTOSEQUENCING AND MUTE FUNCTIONS. − − ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 1 TZVA 05/10 5x1 AND 10x1 VIDEO & AUDIO SWITCHER TZVA 05/10 INSTUCTIONS FOR USE MANUAL 9.0 INDEX 1.0 Overview 2.0 Power 3.0 Settings 4.0 Installation 5.0 Local command Main input 6.0 Command by dry contacts and tally 7.0 Auxiliary functions 8.0 Host control 9.0 Technical data 10.0 Notes Mark 10.0 NOTES You are kindly requested to read the present manual before installing the TZVA 05/10. Manufacturer does not assume any liability for damages due to the use, even correct, of its products. Data and specifications may change without notice. paid. ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 2 TZVA 05/10 5x1 AND 10x1 VIDEO & AUDIO SWITCHER 1.0 OVERVIEW Thanks for purchasing this product. Please check the contents of the packing. It contains: − The TZVA…… unit − The present user manual − The AC adapter code ADM 001 TZVA 05/10 is a mechanical video and audio switcher with 5 and 10 inputs. Reliable and versatile it's suited for professional and multimedial use. The unit is bi-directional and may be useful where one source may be routed alternatively towards 5 or 10 destinations. ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 3 TZVA 05/10 5x1 AND 10x1 VIDEO & AUDIO SWITCHER Fig. 1 CONNECTIONS OF TZVA 05 4 SOURCE 1 DESTINATION ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 4 TZVA 05/10 5x1 AND 10x1 VIDEO & AUDIO SWITCHER 6.0 COMMAND BY DRY CONTACTS AND TALLY TZVA 05/10 5x1 AND 10x1 VIDEO & AUDIO SWITCHER 2.0 POWER By five (ten) external dry contacts connected to connector DB25p.f. REMOTE it's possible to route the five (ten) inputs. The relative tally signals are provided for lighting-up the external leds as indicated below. TZVA 05/10 is powered only by the AC adapter code ADM 001 equipped with the unit. Servicing must be made by qualified personnel The adapter must be fitted in a 220-240 Vac /50 Hz socket TZVA 10 ONLY CONNECTIONS 1 TALLY 1 2 TALLY 2 3 TALLY 3 4 TALLY 4 5 TALLY 5 ATTENTION 6 TALLY 6 7 TALLY 7 For the best results use high efficiency8leds. TALLY 8 9 TALLY 9 10 TALLY 10 11 AUTOSEQ 12 RS232RX 13 MUTE 14 15 16 17 18 19 20 21 22 23 24 25 - INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 INPUT 7 INPUT 8 INPUT 8 INPUT 10 +5 VDC GND - ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 TZVA 05/10 5x1AND 10x1 VIDEO & AUDIO SWITCHER 3.0 SETTINGS The unit has inside the setting (JP1) for the autosequencing time (seechapter 7.1): ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 6 TZVA 05/10 5x1AND 10x1 VIDEO & AUDIO SWITCHER 4.0 INSTALLATION a) Be sure that all the units to be installed are in OFF state. b) Connect the sources and destination video and audio as illustrated: ATTENTION ONLY one destination must be connected to the output c) Power the unit as described in chapter 2.0 and check that the led in the pushbutton 1 lights up. VIDEO INPUTS VIDEO OUTPUT AUDIO INPUTS AUDIO OUTPUT VIDEO INPUTS AUDIO INPUTS 5.0 LOCAL COMMAND The switcher TZVA 05/10 may be controlled by the five (ten) pushbuttons on the front panel. The lighting up of the led indicates which source is routed on the output. At the power-on the source 1 is automatically activated. ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 7 VIDEO OUTPUT AUDIO OUTPUT TZVA 05/10 5x1 AND 10x1 VIDEO & AUDIO SWITCHER 6.0 COMMAND BY DRY CONTACTS AND TALLY 2.0 POWER By five (ten) external dry contacts connected to connector DB25p.f. REMOTE it's possible to route the five (ten) inputs. The relative tally signals are provided for lighting-up the external leds as indicated below. 1 2 3 4 5 6 7 8 9 10 TALLY 1 TALLY 2 TALLY 3 TALLY 4 TALLY 5 TALLY 6 TALLY 7 TALLY 8 TALLY 9 TALLY 10 11 AUTOSEQ 12 RS232RX 13 MUTE 14 15 16 17 18 19 20 21 22 23 24 25 INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 INPUT 7 INPUT 8 INPUT 8 INPUT 10 +5 VDC GND - TZVA 05/10 is powered only by the AC adapter code ADM 001 equipped with the unit. Servicing must be made by qualified personnel The adapter must be fitted in a 220-240 Vac /50 Hz socket TZVA 10 ONLY CONNECTIONS - ATTENTION For the best results use high efficiency leds. ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 8 ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 5 TZVA 05/10 5x1 AND 10x1 VIDEO & AUDIO SWITCHER 7.0 AUXILIARY FUNCTIONS TZVA 05/10 has two auxiliary functions which can be activated by two dry contacts connected to connector DB25p. f. REMOTE. Function stays active until the relative pin is connected to GND (pin 25). 7.1 AUTOSEQUENCING The five (ten) inputs are routed alternatively with a period of 4 or 10 seconds. The period is defined by the position of the jumper inside the unit. (See chapter 3.0) 7.2 MUTE The output is left open. ATTENTION AUTOSEQUENCING and MUTE are mutually exclusive. Priority is: MUTE AUTOSEQUENCING 1 TALLY 1 14 INPUT 1 2 TALLY 2 15 INPUT 2 3 TALLY 3 16 INPUT 3 4 TALLY 4 17 INPUT 4 5 TALLY 5 18 INPUT 5 6 TALLY 6 19 INPUT 6 7 TALLY 7 20 INPUT 7 8 TALLY 8 21 INPUT 8 9 TALLY 9 22 INPUT 8 10 TALLY 10 23 INPUT 10 11 AUTOSEQ 24 +5 VDC 12 25 GND - - RS232RX 13 MUTE ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 9 TZVA 05/10 5x1 AND 10x1 VIDEO & AUDIO SWITCHER 8.0 HOST CONTROL TZVA 05/10 may be controlled in all its functions by host computer sending an exadecimal character. Transmission is RS 232, 8 bits, 1 stop bit, no parity. Baud rate is 2400. It contains: − The Character must be sent to pin #12 of connector DB25 p.f. REMOTE. GND is pin #25. − In the table below are shown the codes sent by host and the relative function on the TZVA 05/10. AUTOSEQUENCING and MUTE are removed repeating the command or sending the code of another command. AUTOSEQUENCING and MUTE are removed pressing a pushbutton on front panel. In this case will be routed the input relative to the pushbutton pressed. Pin # 12 sub - D 31h 32h 33h 34h 35h 36h 37h 38h 39h 3Ah 3Bh 3Ch 3Dh 52h 53h 54h FUNCTION INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 INPUT 7 INPUT 8 INPUT 9 INPUT 10 AUTOSEQ MUTE ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 10 − TZVA 05/10 5x1 AND 10x1 VIDEO & AUDIO SWITCHER 9.0 TECHNICAL DATA Video inputs : 5 with BNC 75Ω term. 10 with BNC 75Ω term. Video Output : 1 with BNC Switching mode :dry contact, break-before-make Audio inputs/out :stereo with RCA socket Main input (with AC adapter ADM 001) Power consumption Size (WXDXH) Weight Operating temp.range Safety EMC : 230 Vac 50 Hz :5 VA :220X105X120 mm :1Kg. :0÷45°C :according to EN 60065 :according to EN 555013 and 55020 Mark 10.0 NOTES The product is guaranteed for two years from date of purchase. TZVA 05/10 INSTUCTIONS FOR USE MANUAL Warranty falls off if defect is due to negligence in use or intervention of unauthorized personnel. In the course of warranty ELPRO will repair free the faulty units. Faulty units must arrive to ELPRO free of charge and with return transportation pre-paid. Out of warranty ELPRO will repair faulty units with cost charged to customer. Units must arrive to ELPRO free of charge and with return transportation prepaid. For any need during installation of TZVA 05/10 and for any other information call hot line ELPRO +39 11 705835 or E-mail [email protected]. Tel. 011/707.19.55 - FAX 011/70.62.10 2 ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 11 INDEX OF ACCESSORIES INFOVIDEO LINE Cod. ELPRO Description − ADC 101 − ADC 105 − ADC 110 − ADC 120 − ADC 130 Cable HDD 15 p. m./f. 1,5 mt. Cable HDD 15 p. m./f. 5,0 mt. Cable HDD 15 p. m./f. 10,0 mt. Cable HDD 15 p. m./f. 20,0 mt. Cable HDD 15 p. m./f. 30,0 mt. − ADC 201 − ADC 301 − ADC 401 − ADC 402 − ADC 501 − ADC 502 Adapter cable HHD 15 p. m./5 BNC MAC Adapter cable DB 15 p. f./HHD 15 p. m. SUN Adapter cable 13W3 f./HHD 15 p. m. SUN Adapter cable 13W3 m./HHD 15 p. f. SGI Adapter cable 13W3 f./HHD 15 p. m. SGI Adapter cable 13W3 m./HHD 15 p. f. − ADC 610 − ADC 630 − ADC 665 RG 59B/U cable BNC/BNC 10mt. RG 59B/U cable BNC/BNC 30mt. RG 59B/U cable BNC/BNC 65mt. − ADC 710 Cable for TCR 03 DB 15 p. m./f. 10mt. − ADM 001 AC Adapter − ADP 010 Connector DB 15 p. m. with cover • − ADP 302 MAC Adapter plug DB 15 p. m./HHD 15 p. f. • − ADR 2U − ADR 3U Rack adapter 2U Rack adapter 3U − ADR 2U BLK − ADR 3U BLK Blank panel 2U Blank panel 3U • • • ELPRO BROADCAST s.r.l. Strada della Pronda 17 - TORINO (ITALY) Tel. 011/707.19.55 - FAX 011/70.62.10 12