Preview only show first 10 pages with watermark. For full document please download

Emc Data Domain Dd7200 - Bull Intel

   EMBED


Share

Transcript

Protection Storage for Backup and Archive EMC Data Domain DD7200 EMC Data Domain deduplication storage systems continue to revolutionize backup, archiving, and disaster recovery with high-speed, inline deduplication. • High-Speed Deduplication: CPU-centric scalability • Scalable Deduplication Storage: Reduces backup storage requirements by 10 to 30 times; Reduces archive storage requirements by up to 5x • Data Invulnerability Architecture: Inline write/read verification, continuous fault detection and healing. Dual disk parity RAID 6. • Easy Integration: Supports leading enterprise backup and archive applications for database, file, email, virtual environments and more • Backup and Archive Consolidation: Efficiently protect backup and/or archive data. Meets governance policies and compliance regulations for archive data • Fast, Efficient and Scalable Disaster Recovery: Reduce bandwidth requirements by up to 99 percent. • Operational Simplicity: Lower administrative costs; Automatic call-home reporting; Reduced footprint • Cloud-Reay: Secure multi-tenancy provides logical isolation of user data High-Speed Deduplication This Data Domain systems provides throughput up to 28.3 TB/hour, enabling more backups to complete sooner, reducing pressure on backup windows. EMC Data Domain systems deduplicate data inline during the backup or archive process, which maximizes backup performance and minimizing disk storage requirements. The deduplicated data can also be replicated over the WAN to a remote site for disaster recovery operations, eliminating the need for tape-based backups, or for consolidating tape backups to a central location. Data Domain Systems provide the capability to co-locate both backup and archive workloads on the same infrastructure allowing greater consolidation by eliminating silos of storage and asscoated overhead. The key to enabling industry leading performance while minimizing disk requirements is the EMC Data Domain Stream-Informed Segment Layout (SISLTM) scaling architecture. Specifically, SISL leverages the continued advancement of CPU performance to continuously increase Data Domain system performance by minimizing disk accesses required to deduplicate data. Scalable deduplication storage By reducing backup storage requirements by 10 to 30x and archive storage requirements by up to 5x. Data Domain systems can help significantly reduce the storage footprint for a typical enterprise data set. With deduplication, multiple months of retention on disk is possible using the same number of “floor tiles” that would traditionally provided only a couple of days of disk staging. Data Invulnerability Architecture Data Domain systems are designed as the storage of last resort – built to ensure you can reliably recover your data with confidence. The EMC Data www.bull.com Domain Data Invulnerability Architecture is built into every Data Domain system to provide the industry’s best defense against data integrity issues. Inline write and read verification protects against and automatically recovers from data integrity issues during data ingest and retrieval. Capturing and correcting I/O errors inline during the backup process eliminates the need to repeat backup jobs, ensuring backups complete on time and satisfy service-level agreements. In addition, continuous fault detection and self-healing ensures data remains recoverable throughout its lifecycle on a Data Domain system. Cloud-Ready DD OS provides secure multi-tenancy that enables data protection-as-aservice for large enterprises and services providers who are looking to offer services based on Data Domain in a private or public cloud. A comprehensive range of services As well as its extensive product portfolio, Atos offers a complete range of services, from consultancy through to system design, integration and maintenance. From the factory preintegration of storage solution right through to project management, installation and support services, Bull StoreWay provides tailored assistance to ensure rapid, well- managed implementation. The Atos Executive Briefing Centers offer a full range of activities and seminars (incl. proofs of concept demonstrations, customer teamings ...). Atos provides the support level 1 & 2 of EMC Data Domain systems. EMC Data Domain DD7200 Technical Specifications TECHNICAL HIGHLIGHTS POWER (Cont'd) Capacity (Raw) Logical Capacity (Standard) Max. Throughput (Other) Frequency Power consumption Redundancy Max. Throughput (DD Boost) Max. Usabe: 428 TB; Max. 4.2 - 21.4 PB (*)(**) 12.6 TB/hr (Maximum throughput achieved using NFS and 10 Gb Ethernet) (**) 28.3 TB/hr (using 10 Gb Ethernet) ENVIRONNEMENTAL CONSTRAINTS SOFTWARE Software Features Management Data Access System Thermal Rating Operating Temperature Global CompressionTM, Data Invulnerability Architecture including inline verification and integrated dual disk parity RAID 6, snapshots, telnet, FTP, SSH, email alerts, scheduled capacity reclamation, Ethernet failover and aggregation, Link Aggregation Control Protocol (LACP), VLAN tagging, IP aliasing. Relative humidity Acoustic Noise Non-operating Temperature Software Options for EMC Data Domain Deduplication Storage Systems are the following: - EMC Data Domain Boost: ADVANCED APPLICATION INTEGRATION, - EMC Data Domain Encryption: SECURE ENCRYPTION OF DATA-AT-REST, - EMC Data Domain Extended Retention: LONG-TERM RETENTION OF BACKUP DATA, - EMC Data Domain Replicator: NETWORK-EFFICIENT REPLICATION, - EMC Data Domain Retention Lock: SECURE DATA RETENTION FOR ARCHIVE DATA - EMC Data Domain Virtual Tape Library: INLINE DEDUPLICATION FOR SAN ENVIRONMENTS EMC Data Domain Enterprise Manager (for single system management and reporting), EMC Data Domain Management Center (Centralized Management for Large Environments), SNMP, and command line interface NFS v3 over TCP, CIFS, DD Boost over 1 GbE or 10 GbE or FC, tape library emulation (VTL) over Fibre Channel and NDMP Tape server. SYSTEM EXPANSION Expansion Shelf © 2017 Copyright Bull SAS All rights reserved - On-the-fly printed on 9/29/2017 3:32:26 AM Disk Drives 50/60 Hz 800 VA Power: 1 +1 redundant, hot-swappable power units; Fans: 5, Hot-swappable, redundant 760 Watts; 2 593 BTU/hr 10 °C to 35°C, 35°C at 7500 feet (derate 1.1°C/1000 feet above 7500 feet to 10,000 feet) 20% to 80% non-condensing Sound Power: LWAd: 7.2 bels; Sound Pressure: LpAm: 56.4 db -40°C to +65°C REGULATORY and SAFETY Safety Emissions Immunity Power Line Harmonics UL 60950-1, CSA 60950-1, EN 60950-1, IEC 60950-1, GS, SABS, GOST, IRAM FCC Class A, EN 55022, CISPR 22, VCCI, BSMI, MIC, ICES-003 EN 55024, CISPR 24 EN 61000-3-2 WARRANTY Standard warranty Warranty extension 1-Y Hardware, 9x5, Next Business Day, parts only Bull’s Global Care offer: Bronze, Silver and Gold levels; depends on location *: Mix of typical enterprise backup data (file systems, databases, email, developer files). The low end of capacity range represents a full backup weekly or monthly, incremental backup daily or weekly, to system capacity. The top end of the range represents full backup daily, to system capacity **: All capacity valeus are calculated using Base 10 ***: No SATA drive for 4 TB drives ES30: up to 5**** shelves/set with 4*** TB, 3 TB or 2 TB drives; up to 4 sets. DS60: up to 2 shelves/set with 4*** TB or 3 TB drives; up to 4 sets. ES30: 15-drive bays per ES30 expansion shelf; SAS (6 Gb/s), 3 TB or 2 TB, & 7200 RPM; SATA (3 Gb/s), 3 TB or 2 TB or 1 TB, & 7200 RPM. DS60: 60-drive bays per DS30 expansion shelf; SAS (6 Gb/s), 3 TB & 4TB, 7200 RPM. ES30 EXPANSION SHELF CHARACTERISTICS EXTERNAL INTERFACE (HOST/EXPANSION): Dual 4 lane 6 Gb/s serial attached SCSI II (SAS) ports per Link Control Card (LCC)—one for host and one for expansion. ****: 5 shelves maximum with ES30, 4 is the recommended maximum PHYSICAL SPECIFICATIONS Form factor Size (HxWxD) Weight Controller: 4U EIA, rack mountable in Data Domain rack. 4 EIA units (WxDxH: 48.8 cm x 90.2 cm x 17.8 cm) 36.29 kg POWER Voltage 200-240 V~ Bull SAS - RCS Versailles B 642 058 739 - All trademarks mentioned herein are the property of their respective owners. Bull reserves the right to modify this document at any time without prior notice. Some offers or parts of offers described in this document may not be available locally. Please contact your local Bull correspondent to know which offers are available in your country. This document has no contractual significance. Bull SAS - rue Jean Jaurès - 78340 Les Clayes-sous-Bois – France UK : Maxted Road, Hemel Hempstead, Herts HP2 7DZ USA : 285 Billerica Road, Chelmsford, MA 01824 www.bull.com