Preview only show first 10 pages with watermark. For full document please download

Emc Test Report

   EMBED


Share

Transcript

Test Report issued under the responsibility of: EMC TEST REPORT EN 301 489-7 V1.3.1:2005-11 Electromagnetic Compatibility for radio equipment and services – mobile and portable radio and ancillary equipment Report Reference No. .....................: G0M-1103-1036 – E-13 Testing Laboratory .........................: Eurofins Product Service GmbH Address.............................................: Storkower Str. 38c 15526 Reichenwalde Germany Accreditation .....................................: DAkkS - Registration number : D-PL-12092-01-01 Applicant’s name ............................: Falcom Wireless Communications GmbH Address.............................................: Gewerbering 6 98704 Langewiesen Germany Test specification: Standard ...........................................: EN 301 489-7 V1.3.1:2005-11 EN 301 489-1 V1.8.1:2008-04 Non-standard test method…………..: N/A Equipment under test (EUT): Product description. ..........................: Asset tracker Model No. .........................................: Rock Hardware Version .............................: Rev.02b Software / Firmware Version ............: 10.00.003 Test result Passed Test Report No.: G0M-1103-1036–E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 1 of 13 REPORT INDEX 1  EQUIPMENT (TEST ITEM) DESCRIPTION 4  1.1  Equipment photos 5  1.2  Supporting Equipment Used During Testing 6  1.3  Input/Output Ports 6  1.4  EUT Operation Modes 6  1.5  Immunity Performance Criteria 7  2  RESULT SUMMARY 8  3  TEST CONDITIONS AND RESULTS 9  3.1  Test Conditions and Results – Immunity to RF electromagnetic fields 9  3.2  Test Conditions and Results – Electrostatic discharge (ESD) 11  Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 3 of 13 1 Equipment (Test item) Description Description Asset tracker Model Rock Serial number unspecified Hardware version Rev.02b Software version 10.00.003 Manufacturer FMO Electronics GmbH Ratings / Power supply 7.5 VDC (battery pack) Number of tested samples 1 Device classification Class B Equipment type mobile use Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 4 of 13 1.1 Equipment photos EUT, TOP EUT, BOTTOM Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 5 of 13 1.2 Supporting Equipment Used During Testing Product Type* Device Manufacturer Model No. SIM radio communication tester Rohde & Schwarz CMU200 Comments *Note: Use the following abbreviations: AE : Auxiliary/Associated Equipment, or SIM : Simulator (Not Subjected to Test) CABL : Connecting cables 1.3 Input/Output Ports The EUT has no input or output ports. 1.4 Mode # 1 EUT Operation Modes Description EUT, connected via GSM900 PCL 5 to radio communication tester. Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 6 of 13 1.5 Immunity Performance Criteria The test results shall be classified in terms of the loss of function or degradation of performance of the equipment under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed between the manufacturer and the purchaser of the product. Definition related to the performance level: based on the used product standard based on the declaration of the manufacturer, requestor or purchaser Criterion A: Definition: During testing, normal performance within the specified limit: Representative parameter Acceptable level of performance Communication link quality and maintenance the RXQUAL of the downlink shall not exceed the value of three during test, no unintentional transmissions in standby Criterion B: Definition: During testing, temporary degradation, or loss of function or performance which is selfrecovering: Representative parameter Acceptable level of performance Communication link quality and maintenance GSM communication link shall be maintained during test, no unintentional transmissions in standby Criterion C: Definition: During testing, temporary degradation, or loss of function or performance which requires operator intervention or system reset occurs: Representative parameter Acceptable level of performance Communication link quality and maintenance GSM communication link not maintained during test, communication link shall be recoverable by operator, no unintentional transmissions in standby. Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 7 of 13 2 Result Summary EN 301 489-7, EN 301 489-1 Product Specific Standard Reference Method Result Remarks EN 55016-2-3:2006 PASS Tested according relevant radio product standard. See G0M-1103-1036-T-51 EN 55022:2006 N/A EUT battery powered EN 301 489-7 Harmonic current emissions Clause 7.1 EN 61000-3-2:2006 N/A EUT battery powered EN 301 489-7 Voltage fluctuations / Flicker Clause 7.1 EN 61000-3-3:1995 N/A EUT battery powered EN 301 489-7 Radiated RF immunity in the frequency range Clause 7.2 80MHz to 2.7GHz EN 61000-4-3:2006 PASS EN 301 489-7 Conducted RF immunity in the frequency range Clause 7.2 0.15MHz to 80MHz EN 61000-4-6:2005 N/A EUT battery powered ISO 7637-2:2004 N/A EUT battery powered EN 301 489-7 Electrostatic Discharge (ESD) Clause 7.2 EN 61000-4-2:2001 PASS EN 301 489-7 Fast Transients, common mode Clause 7.2 EN 61000-4-4:2004 N/A EUT battery powered EN 301 489-7 Surges Clause 7.2 EN 61000-4-5:2006 N/A EUT battery powered EN 301 489-7 Voltage dips and interruptions Clause 7.2 EN 61000-4-11:2004 N/A EUT battery powered Requirement – Test EN 301 489-7 Radiated EMC emissions in the frequency range Clause 7.1 30 MHz to 6000 MHz EN 301 489-7 Conducted EMC emissions in the frequency range Clause 7.1 150kHz to 30 MHz EN 301 489-7 Transients and surges in the vehicular Clause 7.2 environment Remarks: Comment regarding test case specific product standard selection: All product specific standards are stated in the headline of the table. If a product dependent part overrides the test specific parameters of a common part, the product dependent part and sub-clause of the test is stated in the table as product standard. If more than one product standard defines the same test case with the same reference method but with different test levels or limits only the most stringent product standard is stated in the table. If different product standards define the same test case but refer to different reference test methods or standards, the test case is shown for each product standard. Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 8 of 13 3 Test Conditions and Results 3.1 Test Conditions and Results – Immunity to RF electromagnetic fields Immunity to RF electromagnetic fields acc. to EN 301 489-7 Verdict: PASS Laboratory Parameters: Required prior to the test During the test Ambient Temperature 15 to 35°C 23°C Relative Humidity 30 to 60% 41% Test according to referenced standards Common Part Reference Method EN 301 489-1 EN 61000-4-3 Frequency range Fully configured sample scanned over the following frequency range 80MHz to 2.7GHz Samples tested on the following number of orientations Number of orientations EUT operating mode 1 80 – 1000 Test level [V/m] 3 1400 – 2700 3 Frequency [MHz] 4 Test parameters and results Frequency Modulation step 80% AM 1kHz 1% 80% AM 1kHz Dwell time Result Criterion 2s PASS A 2s PASS A 1% Comments: Test Equipment Used Description Manufacturer Model Identifier Cal. Date Cal. Due Generator R&S SME06 Amplifier Amplifier Research Inv. No. 0100 Oct 09 Oct 11 100W1000M1 Inv. No. 0237 System calibration Amplifier Amplifier Research 60S1G3 Inv. No. 0448 System calibration Antenna Frankonia BTA-H Inv. No. 0472 System calibration Horn antenna Schwarzbeck BBHA 9120C Inv. No. 0019 Aug 06 Aug 11 Millivoltmeter R&S URV55 Inv. No. 0348 Apr 10 Apr 11 Directional Coupler MEB RK100 Inv. No. 0372 System calibration Directional Coupler Narda 3002-20 Inv. No. 0145 System calibration EMI Receiver R&S ESCS30 Inv. No. 0476 Jun 10 Jun 11 Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 9 of 13 Measurement uncertainties Frequency range [MHz] Expanded uncertainty [dB] 80 – 3000 2.7 Test setup Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 10 of 13 3.2 Test Conditions and Results – Electrostatic discharge (ESD) Electrostatic discharge acc. to EN 301 489-7 Verdict: PASS Laboratory Parameters: Required prior to the test During the test Ambient Temperature 15 to 35°C 23°C Relative Humidity 30 to 60% 41% Air pressure 860mbar to 1060mbar 1117mbar Test according to referenced standards Common Part Reference Method EN 301 489-1 EN 61000-4-2 Discharge location See photo documentation of the test set-up and tabulated results All external locations accessible by hand, Horizontal plate (HCP) Vertical coupling plate (VCP) EUT operating mode 1 Test parameters and results Number of discharges per Discharge level [kV] location (each polarity) Positive Negative Discharge type Result Criterion Contact – direct 2/4 2/4 10 PASS A Contact – indirect 2/4 2/4 10 PASS A Air -direct 2/4/8 2/4/8 10 PASS A Comments: Test Equipment Used Description Manufacturer Model Identifier Cal. Date Cal. Due ESD gun Schlöder SESD 30000 Inv. No. 0001 Jan 09 Jan 11 Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 11 of 13 Test setup: contact discharge Test setup: air discharge Test setup: indirect discharge Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 12 of 13 EUT: discharge locations → Contact discharge → Air discharge Test Report No.: G0M-1103-1036-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 13 of 13