EME1TH1-001 February 2010 MT1000A-85-R4 EME1TH2-005 EME1TH3-015 AlertWerks™ Dual Temperature/Humidity Sensors Measures temperature from -40 to +167° F in 1° F increments. Measures 0 BLACK to 100%BOX relative humidity with 1% resolution and accuracy of ±3% at 77° F. ® Specifications Temperature: Humidity: Communications Cable — RJ-45 jack to temperature sensor using UTP CAT5 wire Communications Cable — RJ-45 jack to humidity sensor using UTP CAT5 wire Measurement Accuracy — Maximum ±4.1 at -40° F, minimum ±0.9 at 68° F and ±4 at +167° F (Maximum ±2.3 at -40° C, minimum ±0.4 at 25° C and ±1.7 at +75° C) Dual Sensor — Automatically detected by the hub Measurement Accuracy — ±4.1 at -40° F, minimum ±0.9 at 25° F, ±4 at 167° F NOTE: The Temperature/Humidity Sensors never need calibration. Relative Humidity — 0 to 100% Measurement Range — -40 to +167° F (-40 to +75° C) Resolution — 1% for the hubs and 0.1% for the base units Measurement Rate — One reading every second Sensor Element — Can get wet without damage Measurement Resolution — 1° F (1° C) when used with the EME102A and EME108A; 0.9° F (0.5° C) when used with the EME134A Power — Powered by the hub (no additional power needed); Power consumption: Typical 7.25 mWatt, 1.45 mA Sensor Type — Semiconductor microprocessor controlled Power — Powered by the hub (no additional power needed); Power consumption: Typical 10.70 mWatt, 2.14 mA To continue, turn this page over… Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: [email protected] Overview The single-port Dual Temperature/Humidity Sensors measure both temperature and humidity in a single sensor. This extends the hub’s capability to measure up to eight temperature and eight humidity sensing parameters by connecting eight dual sensors. Plug up to two dual sensors into the RJ-45 jacks on the EME102A and up to eight sensors on the EME108A. Connect up to eight dual sensors on the EME134A and eight more on each expansion module (EME1X8). Specially designed CAT5 cable ensures a correct reading up to 100 feet (30.4 m). Models are available with 1-, 5-, or 15-foot (0.3-, 1.5-, or 4.5-m) cable, so you can position them in hot spots. NOTE: The 5-foot version (EME1TH2-005) can be extended up to 1000 feet (304.8 m). The 15-foot cable version (EME1TH3-015) is waterproof. When you plug the dual sensor into an RJ-45 port, the hub will autodetect the sensor, and it will display temperature and humidity for each RJ-45 port. A built-in graph option is included on the hubs for graphing temperature and humidity variations over a period of time. Each temperature/humidity sensor has its own SNMP OID so you can collect and graph the data at 0.3° F (0.2° C) resolution over the network using an external application such as MRTG. Features • RJ-45 connection for easy and simple installation. • Full autosensing including disconnect alarm. • Supports cable distances up to 1000 feet (304.8 m). • Waterproof version available (EME1TH3-015). © Copyright 2011. Black Box Corporation. All rights reserved. Printed in U.S.A. Black Box® and the Double Diamond logo are registered trademarks, and AlertWerks is a trademark, of BB Technologies, Inc. Any third-party trademarks appearing in this publication are acknowledged to be the property of their respective owners. EME1TH1-001, version 1 FREE, live, 24/7 Tech Support is just 30 seconds away. 724-746-5500 | blackbox.com