Preview only show first 10 pages with watermark. For full document please download

Emergency Stop Relays, Safety Gate Monitors

   EMBED


Share

Transcript

Emergency Stop Relays, Safety Gate Monitors Category 3, EN 954-1 PNOZ X5 Technical Details Electrical Data Supply Voltage Tolerance Emergency stop relay and safety gate monitor in accordance with VDE 0113-1, 11/98, EN 60204-1, 12/97 and IEC 204-1, 11/98. Features ● Single-channel or dual-channel operation without detection of shorts across the input contacts ● Designed for operation using semiconductor outputs ● 12 VDC version available for automotive applications Approvals PNOZ X5 ● ● ● PNOZ X5 AC: 24 V DC: 12, 24 V 24 VAC/DC: 85 ... 110 % 12 VDC: 80 ... 120 % 24 V: 160 %, 12 V: 20 % Approx. 2 W/3 VA 24 VDC/25 mA, 12 VDC/60 mA 1 Residual Ripple DC Power Consumption Voltage and Current at the Input and Reset Circuits and Feedback Control Loop Switching Capability in accordance with EN 60947-4-1, 10/91 AC1: 240 V/6 A/1500 VA DC1: 24 V/4 A/100 W EN 60947-5-1, 10/91 (DC13: 6 cycles/min.) AC15: 230 V/5 A; DC13: 24 V/4A Output Contacts 2 safety contacts (N/O) Contact Fuse Protection 6 A quick or 4 A slow (EN 60947-5-1, 10/91) Times Delay-on Energisation Automatic reset : 24 VAC/DC: max. 150 ms 12 VDC: max. 250 ms Manual reset : 24 VAC/DC: max. 100 ms 12 VDC: max. 150 ms Delay-on De-energisation K1, K2 24 VAC/DC: max. 30 ms 12 VDC: max. 30 ms Recovery Time Approx. 1 s Simultaneity channel 1/2 ¥ Max. Supply Interruption before De-energisation Approx. 10 ms Mechanical Data Maximum Cross Section of 2 x 1.5 mm 2 or 1 x 2.5 mm2 External Conductors Single-core or multi-core with crimp connectors Dimensions (H x W x D) 87 x 22.5 x 122 mm Weight 225 g Description Operating Modes ● 22.5 mm, S-95 housing, DIN-Rail mounting ● Relay outputs, positive-guided: 2 safety contacts (N/O) ● Connections for – E-STOP button – safety gate limit switch – reset button ● LEDs for channel 1, channel 2 and power ● Increase in the number of safety contacts available by connecting expander modules. ● ● ● ● Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: [email protected] Single-channel operation Dual-channel operation Automatic reset Manual reset NSG-D-2-035-07/01 1-1 Emergency Stop Relays, Safety Gate Monitors Category 3, EN 954-1 PNOZ X5 ● Increase in safety contacts The number of output contacts can be increased by using expander modules or relays/contactors with positive-guided contacts. Internal Wiring Diagram Input circuits UB Reset circuit A1 (L+) A2 (L-) S11 S33 S34 S22 S12 S12 1 Start Unit Safety contacts 13 23 1L1 K1 K4 Start Unit S33 K2 K5 S34 13 14 24 14 External Wiring K4 ● Example 1 Dual-channel E-STOP wiring with manual reset. ● Example 4 Dual-channel safety gate control with manual reset. 1L2 S33 S12 S33 S11 K5 S1 S1 S3 S11 S3 S2 S22 S34 S12 S22 ● Example 2 Dual-channel E-STOP wiring with automatic reset. S11 S33 S1 S34 – Key S1/2: E-STOP or safety gate switch S3: Reset button Switch operated Gate open S12 S22 S34 Gate closed ● Example 3 Single-channel E-STOP wiring with manual reset. S11 S33 S12 S1 S3 S12 S22 S34 Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: [email protected] NSG-D-2-035-07/01 Emergency Stop Relays, Safety Gate Monitors Category 3, EN 954-1 PNOZ X5 General Technical Data Unless stated otherwise in the technical details for the specific unit Electrical Data Frequency Range AC Residual Ripple DC Contact Material Continuous Duty Environmental Data EMC Vibration in accordance with EN 60068-2-6, 04/95 Climatic Suitability Airgap Creepage Ambient Temperature Storage Temperature Mechanical Data Torque Setting on Connection Terminals Mounting Position Housing Material Protection 1 50 ... 60 Hz 160 % AgSnO2 100 % EN 50081-1, 01/92, EN 50082-2, 03/95 Frequency: 10 ... 55 Hz, Amplitude: 0.35 mm DIN IEC 60068-2-3, 12/86 DIN VDE 0110 part 1, 04/97 -10 ... +55 °C -40 ... +85 °C 0.6 Nm (screws) Any Thermoplast Noryl SE 100 Mounting: IP 54 Housing: IP 40 Terminal Range: IP 20 The units were tested in accordance with the relevant standards current at the time of development. Order References Type PNOZ X5 UB 24 V DC Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: [email protected] Order No. 774 325 NSG-D-2-035-07/01 1-3