Preview only show first 10 pages with watermark. For full document please download

En P 93

   EMBED


Share

Transcript

PS PS R C 14.2 9.3 5.3 US R50044271 E158859 Features Electrostatic capacitance Between open Contacts Between coil & Contacts Between Contact Poles Approx.0.4pF Approx.0.9pF Approx.0.2pF Item 4.41 of IEC 61810-7 Item 4.41 of IEC 61810-7 Item 4.41 of IEC 61810-7 Insulation Resistance 1000M Item 7 of IEC 60255-5 min (at 500VDC) Dielectric Strength Surface mount Type with “L ” SMT shaped Terminals. Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VAC. Monostable or bistable relays Single and double Coil magnet latching Type available. Application for Telecommunication Equipment,Office Equipment, Security Alarm Systems, Measuring instruments, Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control. Ordering Information 12 W 3 Coil rated voltage(V) DC:3,4.5,5,6,9,12,24 4 Contact material Nil: AgPd W: AgNi 2C DPDT(B-M) Bifurcated Crossbar AgPd(Stationary Contact: Gold clad ) AgNi(Gold clad 1A,2A/30VDC; 0.5A/125VAC 60W 62.5VA Min. Switching load 0.01mA/10mV 220VDC 250VAC Max. Switching Current:2A 50m 5 Operation al life Electrical Mechanical Item 6 of IEC 60255-5 Item 6 of IEC 60255-5 Item 6 of IEC 60255-5 Surge Withstand Voltage Between open Contacts Between coil & Contacts Between Contact Poles 1500V 1500V 2500V FCC 68 FCC 68 FCC 68 Functional:500m/s 2 11ms; Survival:1000 m/s2 6ms IEC 68-2-27 Test Ea Shock resistance Terminals strength Solderability 10~55Hz Double amplitude Functional 3mm Survival:5mm 5N 235 2 3 0.5s Temperature Range Mass -40~85 (-40~185 F) 1.5g Vibration resistance Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop 1000VAC 1min 1000VAC 1min 1000VAC 1min IEC 68-2-21 Test Ua1 IEC 68-2-20 Test Ta method 1 Reference Value Safety approvals Item 4.12 of IEC 61810-7 Safety approval UL&CUR Item 4.30 of IEC 61810-7 Load 1A,2A/30VDC 0.5A/125VAC 5 2 10 (DC AgPd);1 10 (DC AgNi) 1 10 5 (AC) 108 IEC 68-2-6 Test Fc TU V 1A/30VDC Item 4.31 of IEC 61810-7 Dimensions CAUTION: Relays previously tested or used above 10mA resistive at 6V maximum recommended for subsequent use in low level applications. DC or peak AC mm/inch open circuit are not 7.5 11.25 12.5 15.0 22.5 30.0 48.0 64.3 144.6 178 257 579 1028 2880 2.25 3.38 3.75 4.50 6.75 9.00 18.0 1 Coil Latching PSL-003 PSL-004 PSL-005 PSL-006 PSL-009 PSL-012 PSL-024 0.14 0.14 0.14 0.14 0.14 0.14 0.20 Operate Time ms 3 4.5 5 6 9 12 24 8.7 13.0 14.5 17.4 26.1 34.8 57.6 90 202.5 250 360 810 1440 3840 Set Coil 3 4.5 5 6 9 12 24 6 9 10 12 18 24 36 45 101 125 180 405 720 1920 2.25 3.38 3.75 4.50 6.75 9.00 18.0 Approx.2 2.25 3.38 3.75 4.50 6.75 9.00 18.0 2.25 3.38 3.75 4.50 6.75 9.00 18.0 0.5 0.02 Reset 0.10 0.10 0.10 0.10 0.10 0.10 0.15 1 7.62 0.3 A B Stand-off 11.5 0.453 0.020 Dimensions Single Side stable 2 3 4 5 1 1 Coil latching 2 3 4 5 1 2 Coil latching 2 3 4 5 SR Approx.2 S Approx.2 0.68 0.027 1 0.039 R S: Set R: Reset (Bottom View) Reset 0.20 0.20 0.20 0.20 0.20 0.20 0.30 2.54 0.1 14.2max. 0.559max. Approx.1 Approx.2 Approx.2 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 31 Index Mark 1.5 0.059 Reset(Max) Reset Coil 45 101 125 180 405 720 1920 -2.25 -3.38 -3.75 -4.50 -6.75 -9.00 -18.0 Release /Reset Time ms 2.02 0.08 Reset(Max) 2 Coil Latching PSK-003 PSK-004 PSK-005 PSK-006 PSK-009 PSK-012 PSK-024 0.3 0.45 0.5 0.6 0.9 1.2 2.4 Coil power W 3 0.118 3 4.5 5 6 9 12 24 Release voltage VDC(min) (10% of rated voltage) 2 0.079 PS-003 PS-004 PS-005 PS-006 PS-009 PS-012 PS-024 Max. Pick up voltage VDC(max) (75%of rated voltage ) 9. 56 0.376 Rated Coil resistance 10% 9.3max. 0.366max. Coil voltage VDC 5.3 +0.4 0.209 +0.016 Coil Parameter Dash numbers 0.5A/125VAC 6.2 +0.4 0.244 0.016 1 2 3 4 1 Part number PS 2 Operating function Nil: Single Side Stable L:1 Coil Latching K:2 Coil Latching Between open Contacts Between coil & Contacts Between Contact Poles 0.25 0.01 PS L Characteristics 2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design criteria. 3.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to be in the magnetically neutral position . 10 9 8 7 6 Index mark (De-energized Position) 10 9 8 7 6 Index mark (Reset Position) 10 9 8 7 Index mark (Reset Position) Wiring diagram (Bottom view) 6 0.6 0.024 1.2 0.047 2.54 0.1 Soldering Pad (for Terminal) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. Temporary glue Pad (for Stand-off A or B) Tolerance 0.1/ 0.004 Mounting (Bottom view) Ningbo Forward Relay Corporation LTD. 32 P Series Data SOLDERING and MOUNTING RECOMMENDATIONS Maximum Switching Power b. In case of Vapor Phase Soldering T3 T2 T1:+120 to+150oC(+248 to+302oF) T2:+180 to+200oC(+356 to+392oF) T1 T3:+245 oC(+473 oF)Max. t1:60 to 90 Sec. t1 t2 T3 T2 o T2:+180 to+200oC(+356 to+392oF) o AC resistive 1.0 0.7 0.5 0.4 0.1 t2:+60Sec.Max. Time 100 70 50 30 125V AC resistive 20 10 20 t2 10 30 50 70 100 200 300 Contact Voltage(V) 0 0 0.2 0.4 0.6 Contact Current(A) 0.8 1.0 Stand-off A 250 300 350 Temperature of Soldering Balth( ) 400 5 2.0 4 Voltage(V) 1.8 1.6 1.4 1.2 Hot Coil 2 1 0.6 Cool Coil Pick-up Voltage 0 20 40 60 80 100 100 70 50 30 20 10 Set/Reset Voltage(PL) Contact Resistance 50 10 Set Voltage 20 10 Ratio to the Nominal Voltaga 20 30 Distribution(%) Distribution(%) 30 40 Reset Voltage 20 30 40 50 60 70 80 Ratio to the Nominal Voltage(%) 90 100 30 20 10 0 10 20 30 40 50 60 70 80 Ratio to the Nominal Voltage(%) 90 100 20 40 10 20 4 2.2 2.0 1.8 1.6 1.4 1.2 0 20 30 40 50 Contact Resistance(m ) 5 4 0.8 0 60 Electrical Life Test P-5(n=10) 0.5A 125VDC Resistive Hot Coil 1.0 0.6 0 10 2.4 n=200 n=100 40 5 Number of Operations( 10 ) 2.6 50 n=100 Pick-up 0 Operating range(P) (200mW Coil) Cool Coil Pick-up Voltage 0 20 40 60 80 100 Voltage(V) 50 Drop-Out ) 0.8 Ambient Temperature( ) Pick-up/Drop-Out Voltage(P) Pick-Up 3 0 200 1.0 0 Distribution(%) 200 Electrical Life Test P-5(n=10) 1A 30VDC Resistive 2.2 Contact Resistance(m Ratio to the Nominal Voltaga Stand-off B 10 0 2.6 Stand-off B 0 Permissible immersion time in soldering balth 2 2.4 0 8 6 Operating range(P) (140mW Coil) Fig.3 The Stand-Offs shown in the Fig. 3 are designed to Anchor Relays temporarily to PC Board with glue before Terminal Soldering. 40 12 10 Time 2. Usage of Stand-Off A & B in Base Area Drop-Out 14 4 DC resistive t1:+40 to 60Ses t1 16 30V DC resistive 0.2 o T3:+215 C(+419 F)Max. t2:+30Sec.Max. 20 20 200 0.3 o T1:+120 to+150 C(+248 to+302 F) T1 300 Contact Current(A) Fig.2 Soldering Temperature Soldering Temperature Fig.1 3.0 2.0 Contact Current(A) a. In case of Infrared Soldering 500 Immersion Time(Sec) 1. Conditions for Terminal Soldering by reflow soldering method Soldering Condition of Terminals Life Curve 5.0 Pick-Up 3 2 Drop-Out 1 Ambient Temperature( ) ) 0 200 5 4 4 4 Time(ms) 2 3 2 Operate Time 30 Variation ratio(%) 5 3 Characteristics of Ambient temperature(P-5) Set/Reset Time(PL) 5 Contact Resistance(m Operate/Release Time(P) (without Diode) Time(ms) Time(ms) Operate/Release Time(P) (without Diode) 3 2 Operate Time 20 100 70 50 30 20 10 Pick-up Voltage 0 2 10 5 Number of Operations( 10 4) 0 -10 Set Time 1 1 -20 1 Release Time Release Time Drop-Out Volltage Reset Time -30 0 0 80 100 120 140 Coil applied Voltage(%) 0 160 0 80 100 120 140 Coil applied Voltage(%) 0 160 0 80 100 120 140 Coil applied Voltage(%) 160 -40 -20 0 20 40 60 80 Mechanical Life Test P-5(n=10) Ambient Temperature( ) 5 Set/Reset Time(PL) Characteristics of Ambient temperature(PL-5) Coil temperature rise(P) 100 105 n=50 80 80 1A Operate 40 20 Set Time 60 Distribution(%) 60 Distribution(%) Distribution(%) 0A Release Reset Time 40 20 60 40 Set Voltage 10 0 -20 33 0 0.5 1 1.5 Time(ms) 2 2.5 0 0 1 2 0 Time(ms) 1 2 0 0 80 100 120 140 Coil applied Voltage(%) 160 100 70 50 30 20 10 Drop-Out Volltage 0 1 5 10 50 100 4 Number of Operations( 10 ) -30 0 Drop-Out 0 200 20 -10 20 2 ) 80 Pick-Up 3 1 30 Variation ratio(%) n=100 Contact Resistance(m 100 Voltage(V) 4 Operate/Release Time(P) -40 -20 0 20 40 60 80 Ambient Temperature( ) Ningbo Forward Relay Corporation LTD. 34