Transcript
PS
PS R
C
14.2 9.3 5.3
US
R50044271
E158859
Features
Electrostatic capacitance Between open Contacts Between coil & Contacts Between Contact Poles
Approx.0.4pF Approx.0.9pF Approx.0.2pF
Item 4.41 of IEC 61810-7 Item 4.41 of IEC 61810-7 Item 4.41 of IEC 61810-7
Insulation Resistance
1000M
Item 7 of IEC 60255-5
min (at 500VDC)
Dielectric Strength
Surface mount Type with “L ” SMT shaped Terminals. Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VAC. Monostable or bistable relays Single and double Coil magnet latching Type available. Application for Telecommunication Equipment,Office Equipment, Security Alarm Systems, Measuring instruments, Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control.
Ordering Information
12 W 3 Coil rated voltage(V) DC:3,4.5,5,6,9,12,24 4 Contact material Nil: AgPd W: AgNi
2C DPDT(B-M) Bifurcated Crossbar AgPd(Stationary Contact: Gold clad ) AgNi(Gold clad 1A,2A/30VDC; 0.5A/125VAC 60W 62.5VA Min. Switching load 0.01mA/10mV 220VDC 250VAC Max. Switching Current:2A 50m 5
Operation al life
Electrical Mechanical
Item 6 of IEC 60255-5 Item 6 of IEC 60255-5 Item 6 of IEC 60255-5
Surge Withstand Voltage Between open Contacts Between coil & Contacts Between Contact Poles
1500V 1500V 2500V
FCC 68 FCC 68 FCC 68
Functional:500m/s 2 11ms; Survival:1000 m/s2 6ms
IEC 68-2-27 Test Ea
Shock resistance
Terminals strength Solderability
10~55Hz Double amplitude Functional 3mm Survival:5mm 5N 235 2 3 0.5s
Temperature Range Mass
-40~85 (-40~185 F) 1.5g
Vibration resistance
Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop
1000VAC 1min 1000VAC 1min 1000VAC 1min
IEC 68-2-21 Test Ua1 IEC 68-2-20 Test Ta method 1
Reference Value
Safety approvals
Item 4.12 of IEC 61810-7
Safety approval
UL&CUR
Item 4.30 of IEC 61810-7
Load
1A,2A/30VDC 0.5A/125VAC
5
2 10 (DC AgPd);1 10 (DC AgNi) 1 10 5 (AC) 108
IEC 68-2-6 Test Fc
TU V 1A/30VDC
Item 4.31 of IEC 61810-7
Dimensions
CAUTION: Relays previously tested or used above 10mA resistive at 6V maximum recommended for subsequent use in low level applications.
DC or peak AC
mm/inch
open circuit are not
7.5 11.25 12.5 15.0 22.5 30.0 48.0
64.3 144.6 178 257 579 1028 2880
2.25 3.38 3.75 4.50 6.75 9.00 18.0
1 Coil Latching PSL-003 PSL-004 PSL-005 PSL-006 PSL-009 PSL-012 PSL-024
0.14 0.14 0.14 0.14 0.14 0.14 0.20
Operate Time ms
3 4.5 5 6 9 12 24
8.7 13.0 14.5 17.4 26.1 34.8 57.6
90 202.5 250 360 810 1440 3840 Set Coil
3 4.5 5 6 9 12 24
6 9 10 12 18 24 36
45 101 125 180 405 720 1920
2.25 3.38 3.75 4.50 6.75 9.00 18.0
Approx.2
2.25 3.38 3.75 4.50 6.75 9.00 18.0
2.25 3.38 3.75 4.50 6.75 9.00 18.0
0.5 0.02
Reset 0.10 0.10 0.10 0.10 0.10 0.10 0.15
1
7.62 0.3
A B
Stand-off
11.5 0.453 0.020
Dimensions
Single Side stable 2 3 4
5
1
1 Coil latching 2 3 4
5
1
2 Coil latching 2 3 4
5
SR
Approx.2
S
Approx.2
0.68 0.027
1 0.039
R S: Set R: Reset (Bottom View)
Reset 0.20 0.20 0.20 0.20 0.20 0.20 0.30
2.54 0.1
14.2max. 0.559max.
Approx.1
Approx.2
Approx.2
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
31
Index Mark
1.5 0.059
Reset(Max)
Reset Coil
45 101 125 180 405 720 1920
-2.25 -3.38 -3.75 -4.50 -6.75 -9.00 -18.0
Release /Reset Time ms
2.02 0.08
Reset(Max)
2 Coil Latching PSK-003 PSK-004 PSK-005 PSK-006 PSK-009 PSK-012 PSK-024
0.3 0.45 0.5 0.6 0.9 1.2 2.4
Coil power W
3 0.118
3 4.5 5 6 9 12 24
Release voltage VDC(min) (10% of rated voltage)
2 0.079
PS-003 PS-004 PS-005 PS-006 PS-009 PS-012 PS-024
Max.
Pick up voltage VDC(max) (75%of rated voltage )
9. 56 0.376
Rated
Coil resistance 10%
9.3max. 0.366max.
Coil voltage VDC
5.3 +0.4 0.209 +0.016
Coil Parameter Dash numbers
0.5A/125VAC
6.2 +0.4 0.244 0.016
1 2 3 4 1 Part number PS 2 Operating function Nil: Single Side Stable L:1 Coil Latching K:2 Coil Latching
Between open Contacts Between coil & Contacts Between Contact Poles
0.25 0.01
PS L
Characteristics
2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design criteria. 3.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to be in the magnetically neutral position .
10
9
8
7
6
Index mark (De-energized Position)
10
9
8
7
6
Index mark (Reset Position)
10
9
8
7
Index mark (Reset Position)
Wiring diagram (Bottom view)
6
0.6 0.024
1.2 0.047
2.54 0.1
Soldering Pad (for Terminal)
NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only.
Temporary glue Pad (for Stand-off A or B) Tolerance 0.1/ 0.004
Mounting (Bottom view)
Ningbo Forward Relay Corporation LTD.
32
P Series Data SOLDERING and MOUNTING RECOMMENDATIONS Maximum Switching Power
b. In case of Vapor Phase Soldering
T3 T2 T1:+120 to+150oC(+248 to+302oF) T2:+180 to+200oC(+356 to+392oF)
T1
T3:+245 oC(+473 oF)Max. t1:60 to 90 Sec. t1
t2
T3 T2 o
T2:+180 to+200oC(+356 to+392oF) o
AC resistive 1.0 0.7 0.5 0.4
0.1
t2:+60Sec.Max.
Time
100 70 50 30
125V AC resistive
20
10
20
t2
10
30 50 70 100 200 300 Contact Voltage(V)
0
0
0.2
0.4 0.6 Contact Current(A)
0.8
1.0
Stand-off A
250 300 350 Temperature of Soldering Balth( )
400
5
2.0
4 Voltage(V)
1.8 1.6 1.4 1.2
Hot Coil
2 1
0.6
Cool Coil
Pick-up Voltage 0
20
40
60
80
100
100 70 50 30 20 10
Set/Reset Voltage(PL)
Contact Resistance
50
10
Set Voltage 20
10
Ratio to the Nominal Voltaga
20
30
Distribution(%)
Distribution(%)
30
40 Reset Voltage
20 30 40 50 60 70 80 Ratio to the Nominal Voltage(%)
90 100
30
20
10
0
10
20 30 40 50 60 70 80 Ratio to the Nominal Voltage(%)
90 100
20
40
10
20
4
2.2 2.0 1.8 1.6 1.4 1.2
0
20
30 40 50 Contact Resistance(m )
5 4
0.8
0
60
Electrical Life Test P-5(n=10) 0.5A 125VDC Resistive
Hot Coil
1.0
0.6 0
10
2.4
n=200
n=100 40
5
Number of Operations( 10 )
2.6
50
n=100 Pick-up
0
Operating range(P) (200mW Coil)
Cool Coil
Pick-up Voltage 0
20
40
60
80
100
Voltage(V)
50
Drop-Out
)
0.8
Ambient Temperature( )
Pick-up/Drop-Out Voltage(P)
Pick-Up
3
0 200
1.0
0
Distribution(%)
200
Electrical Life Test P-5(n=10) 1A 30VDC Resistive
2.2
Contact Resistance(m
Ratio to the Nominal Voltaga
Stand-off B
10
0
2.6
Stand-off B
0
Permissible immersion time in soldering balth
2
2.4
0
8 6
Operating range(P) (140mW Coil)
Fig.3
The Stand-Offs shown in the Fig. 3 are designed to Anchor Relays temporarily to PC Board with glue before Terminal Soldering.
40
12 10
Time
2. Usage of Stand-Off A & B in Base Area
Drop-Out
14
4 DC resistive
t1:+40 to 60Ses t1
16
30V DC resistive
0.2
o
T3:+215 C(+419 F)Max.
t2:+30Sec.Max.
20 20
200
0.3
o
T1:+120 to+150 C(+248 to+302 F) T1
300
Contact Current(A)
Fig.2 Soldering Temperature
Soldering Temperature
Fig.1
3.0 2.0 Contact Current(A)
a. In case of Infrared Soldering
500
Immersion Time(Sec)
1. Conditions for Terminal Soldering by reflow soldering method
Soldering Condition of Terminals
Life Curve
5.0
Pick-Up
3 2
Drop-Out
1
Ambient Temperature( )
)
0 200
5
4
4
4
Time(ms)
2
3
2
Operate Time
30 Variation ratio(%)
5
3
Characteristics of Ambient temperature(P-5)
Set/Reset Time(PL)
5
Contact Resistance(m
Operate/Release Time(P) (without Diode)
Time(ms)
Time(ms)
Operate/Release Time(P) (without Diode)
3
2
Operate Time
20
100 70 50 30 20 10
Pick-up Voltage
0
2
10
5
Number of Operations( 10 4)
0 -10
Set Time 1
1
-20
1
Release Time
Release Time
Drop-Out Volltage
Reset Time -30
0
0
80
100 120 140 Coil applied Voltage(%)
0
160
0
80
100 120 140 Coil applied Voltage(%)
0
160
0
80
100 120 140 Coil applied Voltage(%)
160
-40
-20
0
20
40
60
80 Mechanical Life Test P-5(n=10)
Ambient Temperature( ) 5
Set/Reset Time(PL)
Characteristics of Ambient temperature(PL-5)
Coil temperature rise(P)
100
105 n=50
80
80
1A
Operate 40
20
Set Time
60
Distribution(%)
60
Distribution(%)
Distribution(%)
0A Release
Reset Time
40
20
60
40
Set Voltage
10 0
-20
33
0
0.5
1
1.5 Time(ms)
2
2.5
0
0
1
2
0 Time(ms)
1
2
0
0
80
100 120 140 Coil applied Voltage(%)
160
100 70 50 30 20 10
Drop-Out Volltage
0
1
5
10
50
100
4
Number of Operations( 10 )
-30 0
Drop-Out
0 200
20
-10 20
2
)
80
Pick-Up 3
1
30 Variation ratio(%)
n=100
Contact Resistance(m
100
Voltage(V)
4 Operate/Release Time(P)
-40
-20
0
20
40
60
80
Ambient Temperature( )
Ningbo Forward Relay Corporation LTD.
34