Preview only show first 10 pages with watermark. For full document please download

Encell - 300ah Data Sheet

   EMBED


Share

Transcript

PRODUCT DATASHEET: 300MG1 Page 1 of 2 Fused Iron™ Battery Maximum Dimensions Width: Length: Height: Terminal Spacing: mm 108 157 360 83 (inches) (4.25) (6.19) (14.17) (3.25) General Specifications Battery Type: Chemical System: Weight (dry): Weight (with electrolyte): Nominal Discharge Voltage Average Cell Capacity C/10 to 0.9V Average Cell Capacity C/5 to 0.9V Average Cell capacity C/2 to 0.9V Terminals: Container: Vent: DI Water Top Up Frequency: Autofill System: System Operation Recommended Charging Charge Voltage Charged Open circuit Voltage Optimum Charging Current Min. Charging Current Max. Cont. Charging Current Max. Pulsed Charging Current Maintenance Charge Initiation Charge Optimum Discharge Current Max Discharge Current Battery Cycle Life @25°C Battery Cycle Life @35°C Battery Life on Float Battery Storage Life Rechargeable, Flooded, Vented Nickel Iron (NiFe) 8.1 kg (17.9 lbs) 11.3 kg (24.8 lbs) 1.2-1.25 Volts (rate dependent) 300 Ah; minimum 270Ah 285Ah; minimum 257Ah 270Ah; minimum 243Ah M8 x 1.25 Polypropylene (VO V0 available) available) Includes Flame Arrestor Depends on Application Available Separately Environment Constant current 1.65V - 1.80V 1.4-1.45V C/5 (60 Amps) C/10 (30 Amps) C/2 (150 Amps) 1C (300 Amps - 0.5 minute) Application Dependent 150% min, 200% max. C/4 - C/10 (30-75 Amps) C/2 (150 Amps) >11,000 cycles @ 80% DOD >6,000 cycles @ 80% DOD 20 yrs. 85 yrs. Discharge Temperature (°C): Charge Temperature (°C): Storage Temperature (°C): Operating Humidity: Temperature Compensation Ah Efficiency (0 to 80% SOC) Ah Efficiency (80 to 100% SOC) Recommended 80% DOD Solar Compatible: Wind Compatible: -30 to +60 (-40 available) -30 to +60 (-40 available) -30 to +60 (-40 available) 5% to 95% non-condensing None 98% 75% 5% - 85% SOC (5% = 1.1V) Yes Yes Transportation Classification: UN2795 Class 8 Advantages Over Lead Acid Technology Parameter Advantage Energy - Deeper depth of discharge capability results in significantly more usable capacity. - More specific energy at recommended depth of discharge. - More volumetric energy density at recommended depth of discharge. Charging - Capable of higher rate charging. Life - Much longer cycle life. - Much longer shelf life. - Longer float charging life. Efficiency - Higher efficiency (energy out / energy in). Temperature - Higher maximum operating temperature. Air conditioning not required. - Higher safe storage temperature. - No air conditioning required. Environment - No lead content. No acid content. Important Notice This datasheet contains typical information specific to products manufactured at the time of its publication. ©Encell Technology - Contents herein do not constitute a warranty.